W912LP-21-B-0001_Attachment_2c_AF-Form-66-Bldg_254_Civil_re-upload.xlsx
Air Force Form XLSX spreadsheet 15 KB Posted
- Attached to
- Renovate Bldg 254 Squadron Operations at 185ARW
- Solicitation number
- W912LP21B0001
About this file
This solicitation package is for a firm fixed-price construction contract to renovate Building 254 at the 185th Air Refueling Wing in Sioux City, Iowa. Renovations include upgrading office, classroom, restroom, and storage spaces; expanding secure and alert facility areas; replacing HVAC, electrical, plumbing, and communications systems; installing fire suppression and mass notification systems; and performing exterior improvements. The contract duration is 365 days with construction valued between $5 million and $10 million. Submittals are required for various building components and construction materials. The solicitation was issued by the US Property and Fiscal Office for the Iowa Army National Guard.
View the file
Other versions and copies of AF Form 66
Show all 20
Who attaches AF Form 66
| State | Files |
|---|---|
| Iowa | 1 |
| Massachusetts | 1 |
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AF-Form-66
| SCHEDULE OF MATERIAL SUBMITTALS | PROJECT No: VSSB192001 | PROJECT TITLE - Design for RENOVATE SQUAD OPS, BUILDING 254 | SOLICITATION/CONTRACT NO. | |||||||||||||||||||
| TO BE COMPLETED BY PROJECT ENGINEER | TO BE COMPLETED BY CONTRACT ADMINISTRATOR | |||||||||||||||||||||
| NO. OF COPIES REQUIRED | DATE CONTRACTOR NOTIFIED | |||||||||||||||||||||
| LINE NUMBER | ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL | DOCUMENTS / REPORTS / CERTS. OF COMPLIANCE | SUSTAINABLE SUBMITTAL INFORMATION | SHOP DRAWINGS | SAMPLES | COLOR SELECTION | MANUFACTURER'S RECOMMENDATIONS | MANUFACTURER'S WARRANTY | CATALOG/PRODUCT DATA | OPERATING/MAINT. INSTRUCTIONS | SCHEDULES | AS-BUILT RECORD DRWGS/SPECS | REQUIRED SUB- MISSION DATE | DATE RECEIVED IN CONTRACTING | DATE TO CIVIL ENGINEERING | RETURN SUSPENSE DATE | FOLLOW-UP | APPROVED | DIS- APPROVED | CONTRACT FOR RE- SUBMITTAL | FINAL APPROVAL | REMARKS |
| 1 | 33 05 13 - MANHOLES AND STRUCTURES | X | ||||||||||||||||||||
| 2 | 33 05 13 - MANHOLES AND STRUCTURES- Manhole and Intake Covers | X | ||||||||||||||||||||
| 3 | 33 05 13 - MANHOLES AND STRUCTURES - Manhole Steps | X | ||||||||||||||||||||
| 4 | 33 05 13 - MANHOLES AND STRUCTURES - Manhole Adjusting Rings | X | ||||||||||||||||||||
| 5 | 33 05 13 - MANHOLES AND STRUCTURES - External Chimney Seals | X | ||||||||||||||||||||
| 6 | 33 05 13 - MANHOLES AND STRUCTURES- Manhole PE Wrap | X | ||||||||||||||||||||
| 7 | 33 05 13 - MANHOLES AND STRUCTURES - Manhole Vacuum Test | X | ||||||||||||||||||||
| 8 | 33 05 13 - MANHOLES AND STRUCTURES - Sanitary Sewer Manhole Exfiltration Test | X | ||||||||||||||||||||
| 9 | 33 11 16- SITE WATER DISTRIBUTION PIPING - Water Main | X | ||||||||||||||||||||
| 10 | 33 11 16- SITE WATER DISTRIBUTION PIPING- Water Main Fittings | X | ||||||||||||||||||||
| 11 | 33 11 16- SITE WATER DISTRIBUTION PIPING - Fire Hydrant Assemblies | X | ||||||||||||||||||||
| 12 | 33 11 16- SITE WATER DISTRIBUTION PIPING - Tracer Wire | X | ||||||||||||||||||||
| 13 | 33 11 16- SITE WATER DISTRIBUTION PIPING - Water Valves | X | ||||||||||||||||||||
| 14 | 33 11 16- SITE WATER DISTRIBUTION PIPING- Valve Boxes | X | ||||||||||||||||||||
| 15 | 33 11 16- SITE WATER DISTRIBUTION PIPING - Corporation Stop | X | ||||||||||||||||||||
| 16 | 33 11 16- SITE WATER DISTRIBUTION PIPING- Water Service Pipe | X | ||||||||||||||||||||
| 17 | 33 11 16- SITE WATER DISTRIBUTION PIPING- Tests | X | ||||||||||||||||||||
| 18 | 33 11 16- SITE WATER DISTRIBUTION PIPING - Disenfection Test | X | ||||||||||||||||||||
| 19 | 33 11 16- SITE WATER DISTRIBUTION PIPING - Compaction Testing | X | ||||||||||||||||||||
| 20 | 33 30 00 - SANITARY SEWERAGE UTILITIES - Sanitary Sewer Service Pipe | X | ||||||||||||||||||||
| 21 | 33 30 00 - SANITARY SEWERAGE UTILITIES - Sanitary Sewer Fittings | X | ||||||||||||||||||||
| 22 | 33 30 00 - SANITARY SEWERAGE UTILITIESS - Tests | X | ||||||||||||||||||||
| 23 | 321313 - CONCRETE PAVING - Design Mixtures | X | ||||||||||||||||||||
| 24 | 321313 - CONCRETE PAVING - Qualification Data | X | ||||||||||||||||||||
| 25 | 321313 - CONCRETE PAVING - Material Certificates | X | ||||||||||||||||||||
| 26 | 321313 - CONCRETE PAVING - Material Test Report (Aggregates) | X | ||||||||||||||||||||
| 27 | 321313 - CONCRETE PAVING - Field Tests | X | ||||||||||||||||||||
| 28 | 321373 - CONCRETE PAVING JOINT SEALANTS - Joint Sealant | X | ||||||||||||||||||||
| 29 | 321723 - PAVEMENT MARKINGS - Pavement Markings | X | ||||||||||||||||||||
| 30 | 321723 - PAVEMENT MARKINGS - Glass Beads | X | ||||||||||||||||||||
| 31 | 321726 - TACTILE WARNING SURFACE - Detectable Warning Panel | X | ||||||||||||||||||||
| 32 | 329200 - TURF AND GRASSES - Seed Certification | X | ||||||||||||||||||||
| 33 | 329200 - TURF AND GRASSES - Fertilizers, Mulch, Pesticides, Herbicides | X | ||||||||||||||||||||
| 34 | 329200 - TURF AND GRASSES - Maintenance Data | X | ||||||||||||||||||||
| 35 | ||||||||||||||||||||||
| 36 | 31 23 33 - TRENCHING, BACKFILLING, AND COMPACTING - Material Source | X | ||||||||||||||||||||
| 37 | 31 23 33 - TRENCHING, BACKFILLING, AND COMPACTING - Field Quality Control | X | ||||||||||||||||||||
| 38 | ||||||||||||||||||||||
| 39 | 32 05 16 - AGGREGATES FOR EXTERIOR IMPROVEMENTS - Gradations | X | ||||||||||||||||||||
| 40 | 32 05 16 - AGGREGATES FOR EXTERIOR IMPROVEMENTS - Quality Control | X | ||||||||||||||||||||
| 41 | ||||||||||||||||||||||
| 42 | 32 05 13 - SOIL MATERIALS - Material Source | X | ||||||||||||||||||||
| 43 | 32 05 13 - SOIL MATERIALS - Quality Control | X |
File details come from the government source that posted it. Updated .