AF 66 GENERAL
| SCHEDULE OF MATERIAL SUBMITTALS | PROJECT NUMBER | PROJECT TITLE | SOLICITATION/CONTRACT NUMBER | ||||||||||||||||||
| NVZR 12-0210 | RPR (SUS) H1 Corrosion Control Deficiencies, Phase 1 | ||||||||||||||||||||
| TO BE COMPLETED BY PROJECT ENGINEER | TO BE COMPLETED BY PROJECT ENGINEER | TO BE COMPLETED BY CONTRACT ADMINISTRATOR | |||||||||||||||||||
| NUMBER OF COPIES REQUIRED | |||||||||||||||||||||
| LINE NUMBER | ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL | ||||||||||||||||||||
| *INDICATES ITEMS THAT REQUIRE ENGINEER/ARCHITECT OF RECORD REVIEW & ACCEPTANCE PRIOR TO SUBMITTAL TO GOVERNMENT | Certification Of Compliance | Shop Drawings | Samples | Color selection | Manufacturer's Recommendation | Manufacturer's Warranty | Catalog Data | Operating Instruction | PLAN OR FORM | TEST | REQUIRED SUBMISSION DATE | DATE RECEIVED IN CONTRACTING | DATE TO CIVIL ENGINEERING | RETURN SUSPENSE DATE | SUBMITTAL NUMBER | DATE CONTRACTOR NOTIFIED | CONTRACTOR RESUBMITTAL | FINAL APPROVAL | REMARKS | ||
| GENERAL | APPROVED | DISAPPROVED | |||||||||||||||||||
| G1 | WORK CLEARANCE REQUEST (AF FORM 103) | 1 | Ph 1 NTP+10 DAYS | ||||||||||||||||||
| G2* | AS-BUILT DATA | 1 | 21 days after construction completion | ||||||||||||||||||
| G3 | CONSTRUCTION PROGRESS SCHEDULE | 1 | Ph 1 NTP+ 10 DAYS | ||||||||||||||||||
| G4 | TESTING LABORATORY IDENTIFICATION | 1 | 95% Design + 10 days | ||||||||||||||||||
| G5 | WARRANTIES | 1 | 10 DAYS BEFORE Final | ||||||||||||||||||
| G6 | OPERATION AND MAINTENANCE MANUALS | 1 | 10 DAYS BEFORE Final | ||||||||||||||||||
| G7 | CONSTRUCTION AND UTILITY DATA SHEETS | 1 | 10 DAYS BEFORE Final | ||||||||||||||||||
| G8 | PROJECT SPECIFIC SAFETY PLAN | 1 | Ph 1 NTP+20 DAYS | ||||||||||||||||||
| G9* | COMPLETE MATERIALS & COLOR BOARD | E | 3 | 3 | E | E | E | E | 7 DAYS BEFORE 65% SUBMITTAL | ||||||||||||
| G10* | 65% DESIGN | 3/E | SEE SCHEDULE | ||||||||||||||||||
| G11* | 95% DESIGN | 3/E | SEE SCHEDULE | ||||||||||||||||||
| G12* | 100% DESIGN | 3/E | SEE SCHEDULE | ||||||||||||||||||
| G13 | Approved FGUA Form 427 | 1 | 95% Design + 10 days |
BROCK, APRIL E GS-11 USAF AMC 6 CONTRACTING SQ/LGCM:
missing G7See
AF 66 ARCHITECTURAL
| SCHEDULE OF MATERIAL SUBMITTALS | PROJECT NUMBER | PROJECT TITLE | SOLICITATION/CONTRACT NUMBER | ||||||||||||||||||
| NVZR 12-0210 | RPR (SUS) H1 Corrosion Control Deficiencies, Phase 1 | ||||||||||||||||||||
| TO BE COMPLETED BY PROJECT ENGINEER | TO BE COMPLETED BY PROJECT ENGINEER | TO BE COMPLETED BY CONTRACT ADMINISTRATOR | |||||||||||||||||||
| NUMBER OF COPIES REQUIRED | |||||||||||||||||||||
| LINE NUMBER | ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL | ||||||||||||||||||||
| *INDICATES ITEMS THAT REQUIRE ENGINEER/ARCHITECT OF RECORD REVIEW & ACCEPTANCE PRIOR TO SUBMITTAL TO GOVERNMENT | Certification Of Compliance | Shop Drawings | Samples | Color selection | Manufacturer's Recommendation | Manufacturer's Warranty | Catalog Data | Operating Instruction | PLAN | TEST | REQUIRED SUBMISSION DATE | DATE RECEIVED IN CONTRACTING | DATE TO CIVIL ENGINEERING | RETURN SUSPENSE DATE | SUBMITTAL NUMBER | DATE CONTRACTOR NOTIFIED | CONTRACTOR RESUBMITTAL | FINAL APPROVAL | REMARKS | ||
| ARCHITECTURAL | APPROVED | DISAPPROVED | |||||||||||||||||||
| A1* | MILLWORK | E | 3/E | 3 | 3 | E | E | E | 7 DAYS BEFORE 65% SUBMITTAL | ||||||||||||
| A2* | DOORS AND HARDWARE | E | E | E | E | E | E | WITH 65% SUBMITTAL | |||||||||||||
| A3* | THERMAL BOARD INSULATION FOR PERIMETER WALLS AT H3 | E | E | E | E | E | 65% SUBMITTAL + 7 DAYS | ||||||||||||||
| A4* | CEILING SYSTEMS | E | E | 3 | 3 | E | E | E | E | 65% SUBMITTAL + 7 DAYS | |||||||||||
| A5* | PAINTS AND COATINGS | E | 3 | 3 | E | E | E | 65% SUBMITTAL + 10 DAYS | |||||||||||||
| A6* | VCT TILE AND PORECLAIN TILE | E | 3 | 3 | E | E | E | 65% SUBMITTAL + 10 DAYS | |||||||||||||
| A7* | CEILING ACCESS HATCHES | E | E | 3 | E | E | E | E | E | 65% SUBMITTAL + 14 DAYS | |||||||||||
| A8* | WALL & CORNER GUARDS | E | 3 | 3 | E | E | E | WITH 95% SUBMITTAL | |||||||||||||
| A9* | FIRE EXTINGUISHERS | E | E | E | E | WITH 95% SUBMITTAL | |||||||||||||||
| 0 |
AF 66 CIVILSTRUCTURAL
| SCHEDULE OF MATERIAL SUBMITTALS | PROJECT NUMBER | PROJECT TITLE | SOLICITATION/CONTRACT NUMBER | ||||||||||||||||||
| NVZR 12-0210 | RPR (SUS) H1 Corrosion Control Deficiencies, Phase 1 | ||||||||||||||||||||
| TO BE COMPLETED BY PROJECT ENGINEER | TO BE COMPLETED BY PROJECT ENGINEER | TO BE COMPLETED BY CONTRACT ADMINISTRATOR | |||||||||||||||||||
| NUMBER OF COPIES REQUIRED | |||||||||||||||||||||
| LINE NUMBER | ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL | ||||||||||||||||||||
| *INDICATES ITEMS THAT REQUIRE ENGINEER/ARCHITECT OF RECORD REVIEW & ACCEPTANCE PRIOR TO SUBMITTAL TO GOVERNMENT | Certification Of Compliance | Shop Drawings | Samples | Color selection | Manufacturer's Recommendation | Manufacturer's Warranty | Catalog Data | Operating Instruction | PLAN | TEST | REQUIRED SUBMISSION DATE | DATE RECEIVED IN CONTRACTING | DATE TO CIVIL ENGINEERING | RETURN SUSPENSE DATE | SUBMITTAL NUMBER | DATE CONTRACTOR NOTIFIED | CONTRACTOR RESUBMITTAL | FINAL APPROVAL | REMARKS | ||
| CIVIL & STRUCTURAL | APPROVED | DISAPPROVED | |||||||||||||||||||
| S1 | STRUCTURAL LINTELS FOR ANY NEW OPENINGS | E | EE | E | E | 65% SUBMITTAL PLUS 21 DAYS | |||||||||||||||
| 0 |
AF 66 MECHANICAL
| SCHEDULE OF MATERIAL SUBMITTALS | PROJECT NUMBER | PROJECT TITLE | SOLICITATION/CONTRACT NUMBER | ||||||||||||||||||
| NVZR 12-0210 | RPR (SUS) H1 Corrosion Control Deficiencies, Phase 1 | ||||||||||||||||||||
| TO BE COMPLETED BY PROJECT ENGINEER | TO BE COMPLETED BY PROJECT ENGINEER | TO BE COMPLETED BY CONTRACT ADMINISTRATOR | |||||||||||||||||||
| NUMBER OF COPIES REQUIRED | |||||||||||||||||||||
| LINE NUMBER | ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL | ||||||||||||||||||||
| *INDICATES ITEMS THAT REQUIRE ENGINEER OF RECORD REVIEW | Certification Of Compliance | Shop Drawings | Samples | Color selection | Manufacturer's Recommendation | Manufacturer's Warranty | Catalog Data | Operating Instruction | PLAN | TEST | REQUIRED SUBMISSION DATE | DATE RECEIVED IN CONTRACTING | DATE TO CIVIL ENGINEERING | RETURN SUSPENSE DATE | SUBMITTAL NUMBER | DATE CONTRACTOR NOTIFIED | CONTRACTOR RESUBMITTAL | FINAL APPROVAL | REMARKS | ||
| MECHANICAL | APPROVED | DISAPPROVED | |||||||||||||||||||
| M1 | HVAC EQUIPMENT AND CONTROLS | 1 | 1 | 1 | 1 | 1 | 95% design + 10 days | ||||||||||||||
| M2 | DUCTWORK, DAMPERS, HANGERS, FITTINGS | 1 | 1 | 1 | 1 | 95% design + 10 days | |||||||||||||||
| M3 | DUCT INSULATION | 1 | 1 | 1 | 1 | 95% design + 10 days | |||||||||||||||
| M4 | REFRIGERANT PIPING AND INSULATION | 1 | 1 | 1 | 1 | 95% design + 10 days | |||||||||||||||
| M5 | EXHAUST FAN | 1 | 1 | 1 | 1 | 1 | 95% design + 10 days | ||||||||||||||
| M6 | TEST AND BALANCE CREDENTIALS | 1 | 95% design + 10 days | ||||||||||||||||||
| M7 | TEST AND BALANCE REPORT | 1 | 95% design + 10 days | ||||||||||||||||||
| M8 | PLUMBING FIXTURES | 1 | 1 | 1 | 1 | 95% design + 10 days | |||||||||||||||
| M9 | DOMESTIC WATER PIPING AND INSULATION | 1 | 1 | 1 | 1 | 95% design + 10 days | |||||||||||||||
| M10 | SANITARY SEWER PIPING AND INSULATION | 1 | 1 | 1 | 1 | 95% design + 10 days | |||||||||||||||
| 0 |
AF 66 ELECTRICAL
| SCHEDULE OF MATERIAL SUBMITTALS | PROJECT NUMBER | PROJECT TITLE | SOLICITATION/CONTRACT NUMBER | ||||||||||||||||||
| NVZR 12-0210 | RPR (SUS) H1 Corrosion Control Deficiencies, Phase 1 | ||||||||||||||||||||
| TO BE COMPLETED BY PROJECT ENGINEER | TO BE COMPLETED BY PROJECT ENGINEER | TO BE COMPLETED BY CONTRACT ADMINISTRATOR | |||||||||||||||||||
| NUMBER OF COPIES REQUIRED | |||||||||||||||||||||
| LINE NUMBER | ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL | ||||||||||||||||||||
| *INDICATES ITEMS THAT REQUIRE ENGINEER/ARCHITECT OF RECORD REVIEW & ACCEPTANCE PRIOR TO SUBMITTAL TO GOVERNMENT | Certification Of Compliance | Shop Drawings | Samples | Color selection | Manufacturer's Recommendation | Manufacturer's Warranty | Catalog Data | Operating Instruction | PLAN | TEST | REQUIRED SUBMISSION DATE | DATE RECEIVED IN CONTRACTING | DATE TO CIVIL ENGINEERING | RETURN SUSPENSE DATE | SUBMITTAL NUMBER | DATE CONTRACTOR NOTIFIED | CONTRACTOR RESUBMITTAL | FINAL APPROVAL | REMARKS | ||
| ELECTRICAL | APPROVED | DISAPPROVED | |||||||||||||||||||
| E1* | receptacles and data devices and | 1 | 1 | 95% DESIGN + 10 DAYS | |||||||||||||||||
| cabling | |||||||||||||||||||||
| E2* | lighting fixtures and controls | 1 | 1 | 95% DESIGN + 10 DAYS | |||||||||||||||||
| E3* | electrical panel and breakers | 1 | 1 | 1 | 95% DESIGN + 10 DAYS | ||||||||||||||||
| E4* | surge protection devices | 1 | 1 | 95% DESIGN + 10 DAYS | |||||||||||||||||
| E5* | electrical relays/contactors | 1 | 1 | 95% DESIGN + 10 DAYS | |||||||||||||||||
| E6* | Communications hardware and | 1 | 1 | 95% DESIGN + 10 DAYS | |||||||||||||||||
| equipment | |||||||||||||||||||||
| 0 |
AF 66 ENVIRONMENTAL
| SCHEDULE OF MATERIAL SUBMITTALS | PROJECT NUMBER | PROJECT TITLE | SOLICITATION/CONTRACT NUMBER | ||||||||||||||||||
| NVZR 12-0210 | RPR (SUS) H1 Corrosion Control Deficiencies, Phase 1 | ||||||||||||||||||||
| TO BE COMPLETED BY PROJECT ENGINEER | TO BE COMPLETED BY PROJECT ENGINEER | TO BE COMPLETED BY CONTRACT ADMINISTRATOR | |||||||||||||||||||
| NUMBER OF COPIES REQUIRED | |||||||||||||||||||||
| LINE NUMBER | ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL | ||||||||||||||||||||
| *INDICATES ITEMS THAT REQUIRE ENGINEER/ARCHITECT OF RECORD REVIEW & ACCEPTANCE PRIOR TO SUBMITTAL TO GOVERNMENT | Certification Of Compliance | Shop Drawings | Samples | Color selection | Manufacturer's Recommendation | Manufacturer's Warranty | Catalog Data | Operating Instruction | PLAN OR FORM | TEST | REQUIRED SUBMISSION DATE | DATE RECEIVED IN CONTRACTING | DATE TO CIVIL ENGINEERING | RETURN SUSPENSE DATE | SUBMITTAL NUMBER | DATE CONTRACTOR NOTIFIED | CONTRACTOR RESUBMITTAL | FINAL APPROVAL | REMARKS | ||
| ENVIRONMENTAL | APPROVED | DISAPPROVED | |||||||||||||||||||
| V1 | ASBESTOS NESHAP SURVEY AND LEAD-BASED PAINT SCREENING RESULTS | 1 | WITH 65% DESIGN | ||||||||||||||||||
| V2 | ASBESTOS RENOVATION OR DEMOLITION NOTIFICATION FORM | 1 | 95% Design + 10 days | ||||||||||||||||||
| V3 | POST ABATEMENT REPORT | 1 | 10 DAY AFTER ABATEMENT | ||||||||||||||||||
| V4 | HAZMAT LIST AND MSDS SHEETS FOR NON-EXEMPT HAZMAT | 1 | 95% Design + 10 days | ||||||||||||||||||
| V5 | CONTRACTOR HAZMAT PROFILE WORKSHEET | 1 | 10 DAYS BEFORE Final | ||||||||||||||||||
| V6 | GREEN PROCUREMENT COMPLIANCE FOR FINISHING MATERIALS | 1 | 10 DAYS BEFORE Final | ||||||||||||||||||
| V7 | CONSTRUCTION AND DEMOLITION DEBRIS TRACKING FORM | 1 | 50% and 100% Completion | ||||||||||||||||||
| V8 | EMERGENCY GENERATOR TECHNICAL DATA SHEET | 1 | 95% + 10 days |