MACC SOLICITATION
SAMPLE PROJECT REVIEW
NVZR 12-0210
REPAIR (SUS) H1 CORROSION CONTROL DEFICIENCIES, PHASE I
6th Air Mobility Wing
Airmen, Mission, Community… Delivering Unsurpassed Airpower !
UNCLASS//FOUO
Airmen, Mission, Community… Delivering Unsurpassed Airpower!
OPR: 6 CES/CECA
Last Updated: 24 June 2014
UNCLASS//FOUO
UNCLASS//FOUO
OBJECTIVES
PROJECT SCOPE
PROJECT LOCATION
EXISTING CONDITIONS
PHASE 1 SCOPE
PROPOSAL TECHNICAL ACCURACY
SUBFACTOR 1: 48 DIVISION CONSTRUCTION SPECIFICATION INSTITUTE (CSI) ESTIMATE
SUBFACTOR 2: SPECIFICATIONS FOR 65% DESIGN
SUBFACTOR 3: PLANS FOR 65% DESIGN
SUBFACTOR 4: LIST OF APPLICABLE CRITERIA
SUBFACTOR 5: DESIGN CALCULATIONS
SUBFACTOR 6: SCHEDULE (GANTT CHART)
SUBFACTOR 7: MAT/EQUIP LIST AND CUT SHEETS >$3K
Last Updated: 24 June 2014
UNCLASS//FOUO
UNCLASS//FOUO
PROJECT LOCATIONS
B9
H-3 H-1
Last Updated: 24 June 2014
UNCLASS//FOUO
UNCLASS//FOUO
EXISTING CONDITIONS
HANGAR 1
E&E OFFICE
E&E BATTERY SHOP106
PAINT / PREP BOOTH
WASH RACK
OFFICES
FIBERGLASS SHOP
BOILER ROOM
BLASTER EQUIPMENT
VACUUM AREA
CLEAN / DIRTY ROOM
HAZMART STORAGE
PPE STORAGE
CORROSION OFFICES
HAZMART OFFICES
CRYO STORAGE
BLASTER EQUIPMENT
Phase 1 scope Phase 2 scope
Last Updated: 24 June 2014
UNCLASS//FOUO
UNCLASS//FOUO
PROJECT SCOPE
Project Renovates Spaces in H1 and H3 to allow realignment of functional areas and free existing space to support a follow-on project for corrosion control area.
RENOVATE 1800 SF OF SPACE IN H-3
DEMO AND RECONFIGURE FOR E&E SHOP REQUIREMENT
RENOVATE 460 SF OF SPACE IN H-1
DEMO AND RECONFIGURE FOR FIBERGLASS SHOP REQUIREMENT
RENOVATION OF 875 SF OF SPACE IN H-1
REPLACE WORN FINISHES FOR WASHRACK GROUP
RELOCATE EQUIPMENT FROM FIBERGLASS SHOP
Last Updated: 24 June 2014
UNCLASS//FOUO
UNCLASS//FOUO
RENOVATE 1800 SF OF SPACE IN H3
(NEW E&E / BATTERY SHOP)
DEMOLITION
REMOVE FLOORING, PANELING, CEILING, DOORS, LIGHTS
DEMO HVAC SYSTEM
ARCHITECTURAL
NEW 5/8” GYP WALLS W/ 3-5/8” 24 GA. GALV STEEL STUDS
NEW DOORS (5 TYPES)
INSTALL CABINETRY
FIRE RATED WALLS FOR BATTERY ROOM
HI PERF FLOOR COATING (SHEET A004) BATTERY ROOM
PLUMBING
NEW SINKS, EYE WASH, POTABLE WATER SUPPLY
NEW SANITARY LATERAL
MECHANICAL
NEW HVAC AND DISTRIBUTION
NEW EXHAUST SYSTEM
ELECTRICAL
NEW QUAD RECEPTICLES WITH 2 DATA/2 VOICE
220V RECEPTACLES FOR BATTERY CHARGING
REFURB/REINSTALL STATIC GROUND BAR FROM H1
REINSTALL 400HZ EQUIP FROM H1
REINSTALL FIXTURES / ADD NEW TO MEET LTG LEVELS
Last Updated: 24 June 2014
UNCLASS//FOUO
UNCLASS//FOUO
The first phase will need to be the Renovation of 1800 SF of space in H-3 to facilitate this relocation of E&E personnel, specifically the battery shop, which will have specific electrical and HVAC requirements.
RENOVATE 460 SF OF SPACE IN H-1
(NEW FIBERGLASS SHOP)
DEMO EXISTING DOORS
DEMO BATTERY CHARGING RECEPTACLES
REMOVE & PROTECT GROUNDING BUS BAR (TO BE REINSTALLED IN H3)
REMOVE & PROTECT 400HZ GENERATOR EQUIPMENT (TO BE REINSTALLED IN H3)
ARCHITECTURAL
NEW 5/8” GYP CEILING W/ ACCESS DOORS
PAINT/PATCH WALLS
NEW DOORS
HI PERF FLOOR COATING (SHEET A004)
MECHANICAL
RE-BALANCE SUPPLY AIR TO MEET UFC 3-401-1 VENTILATION RATES
RE-BALANCE EXISTING EXHAUST HOODS TO MEET UFC 3-410-04N
INSTALL WALL MOUNTED WARNING PLACARDS
ELECTRICAL
NEW 220V RECEPTACLE FOR FIBERGLASS EQUIPMENT
NEW T5 LIGHTING FIXTURES W/ DUAL TECH OCC SENSORS THAT COMPLY W/ MACDILL & UFC LIGHTING STANDARDS.
Last Updated: 24 June 2014
UNCLASS//FOUO
UNCLASS//FOUO
Note the higher cost for this renovation. The Renovation of this 460 SF of space in H-1 will require explosion codes to be met IE: explosion-proof, thicker walls, as well as electrical and HVAC codes to accommodate the new fiberglass shop location.
RENOVATE 875 SF OF SPACE IN H1
(NEW WASH RACK OFFICE)
FLOORING AND BASE
ARCHITECTURAL
NEW 5/8” GYP CEILING W/ ACCESS DOORS
PAINT/PATCH WALLS
HI PERF FLOOR COATING (SHEET A004)
NEW DOORS
MECHANICAL
RE-BALANCE SUPPLY AIR TO MEET UFC 3-401-1 VENT RATES
RE-BALANCE EXISTING EXH HOODS TO MEET UFC 3-410-04N
INSTALL WALL MOUNTED WARNING PLACARDS
ELECTRICAL
NEW 220V RECEPTACLE FOR FIBERGLASS EQUIPMENT
NEW T5 LIGHTING FIXTURES W/ DUAL TECHNOLOGY OCCUPANCY SENSORS THAT COMPLY W/ MACDILL & UFC LIGHTING STANDARDS.
Last Updated: 24 June 2014
UNCLASS//FOUO
UNCLASS//FOUO
The Renovation of this 875 SF of space in H-1 will require some cosmetic renovation such as meeting current lighting codes for wash rack personnel relocation.
RELOCATE EQUIPMENT TO NEW FIBERGLASS ROOM
RELOCATE EXISTING EQUIPMENT TO NEW FIBERGLASS ROOM.
Last Updated: 24 June 2014
UNCLASS//FOUO
UNCLASS//FOUO
The Renovation of this 875 SF of space in H-1 will require some cosmetic renovation such as meeting current lighting codes for wash rack personnel relocation.
TECHNICAL PROPOSAL
SAMPLE PROJECT PROPOSAL ACCURACY
SUBFACTOR 1: 48 DIVISION CONSTRUCTION SPECIFICATION INSTITUTE (CSI)
SUBFACTOR 2: SPECIFICATIONS FOR 65% DESIGN
SUBFACTOR 3: PLANS FOR 65% DESIGN
SUBFACTOR 4: LIST OF APPLICABLE CRITERIA
SUBFACTOR 5: DESIGN CALCULATIONS
SUBFACTOR 6: SCHEDULE (GANTT CHART)
SUBFACTOR 7: MATERIALS/EQUIPMENT LIST AND CUT SHEETS FOR ITEMS GREATER THAN $3,000
Last Updated: 24 June 2014
UNCLASS//FOUO
UNCLASS//FOUO
SUBFACTOR 1
48 CSI EVALUATION
To receive an "acceptable" rating, the contractor must show he/she understands the full scope of the sample project and has accurately determined the necessary types and quantities of labor, material, and equipment required to complete the project.
Last Updated: 24 June 2014
UNCLASS//FOUO
UNCLASS//FOUO
SUBFACTOR 1 (CONT)
COMPONENT LEVEL
YOU WILL NEED TO PROVIDE U/M AND QUANTITIES
YOU DO NOT PROVIDE PRICING
Last Updated: 24 June 2014
UNCLASS//FOUO
UNCLASS//FOUO
EXAMPLE CSI DIVISION
(ELECTRICAL)
THIS IS A SAMPLE FROM A DIFFERENT PROJECT
UNIT AND TOTAL COSTS MAY BE REDACTED FROM YOUR PROPOSAL
Last Updated: 24 June 2014
UNCLASS//FOUO
UNCLASS//FOUO
SUBFACTOR 2
SPECIFICATIONS
MUST BE IN CSI FORMAT
INITIAL PROVIDED IN 30% DRAWING SET
ADDITIONAL SPECIFICATIONS MUST BE ADDED AS NECESSARY
To receive an "acceptable" rating, the contractor must ensure each of the disciplines are completely and accurately addressed, correct design guidance/criteria is used, and the specifications match the drawings, calculations, and rest of the design package
Last Updated: 24 June 2014
UNCLASS//FOUO
UNCLASS//FOUO
SUBFACTOR 3
PLANS
SEE APPENDIX “E” REQUIREMENTS BY DISCIPLINE (ARCHITECTURAL, MECHANICAL, PLUMBING, ELECTRICAL) DRAWINGS SHALL MEET CURRENT CAD/BIM TECHNOLOGY CENTER A/E/C CADD STANDARDS RELEASE 4.0 COORDINATE SYSTEM USED FOR CADD FILES SHALL BE THE STATE PLANE COORDIANTES NORTH AMERICAN DATUM 1983 PROJECTION FLORIDA WEST 0902 FEET To receive an "acceptable" rating, the contractor's drawings must be complete, accurate, and in accordance with tri-service standards.
Last Updated: 24 June 2014
UNCLASS//FOUO
UNCLASS//FOUO
SUBFACTOR 3 (CONT)
PLANS - ARCHITECTURAL
** NOT COMPREHENSIVE LIST … SEE APPENDIX E **
WALL ELEVATIONS
FULL SECTION DETAILS
REFLECTED CEILING PLANS
MATERIAL AND COLOR BOARD
FINISH SCHEDULES
DOOR SCHEDULES
FIRE RATINGS
Last Updated: 24 June 2014
UNCLASS//FOUO
UNCLASS//FOUO
SUBFACTOR 3 (CONT)
PLANS - PLUMBING
** NOT COMPREHENSIVE LIST … SEE APPENDIX E **
PLUMBING SYSTEM SIZES, PIPE RUNS, ETC.
WALL/ROOF PENETRATION DETAILS
EQUIPMENT AND COMPONENT DETAILS INCLUDING ISOMETRIC DETAILS OF PLUMBING WITH PIPING CONNECTIONS.
SECTION DETAILS TO VERIFY THE ELIMINATION OF EQUIPMENT AND COMPONENT CLEARANCE CONFLICTS.
PLUMBING FIXTURE AND EQUIPMENT SCHEDULES.
Last Updated: 24 June 2014
UNCLASS//FOUO
UNCLASS//FOUO
SUBFACTOR 3 (CONT)
PLANS - MECHANICAL
** NOT COMPREHENSIVE LIST … SEE APPENDIX E **
ALL ASPECTS OF THE AIR CONDITIONING SYSTEM INCLUDING SIZE, DUCT RUNS, ETC.
ALL WALL/ROOF PENETRATION DETAILS
ALL EQUIPMENT AND COMPONENT DETAILS INCLUDING ISOMETRIC DETAILS OF MECHANICAL ROOMS WITH DUCTWORK AND PIPING CONNECTIONS.
SECTION DETAILS TO VERIFY THE ELIMINATION OF EQUIPMENT AND COMPONENT CLEARANCE CONFLICTS.
CONTROLS DETAILS INCLUDING PROPOSED CONTROL POINTS, EQUIPMENT CONTROL SCHEDULE, LOGIC DIAGRAMS, ETC
SEQUENCE OF OPERATIONS
EQUIPMENT SCHEDULES
Last Updated: 24 June 2014
UNCLASS//FOUO
UNCLASS//FOUO
SUBFACTOR 3 (CONT)
PLANS - ELECTRICAL
** NOT COMPREHENSIVE LIST … SEE APPENDIX E **
POWER DISTRIBUTION SYSTEM, INCLUDING EQUIPMENT AND DEVICE PLACEMENT AND CIRCUITING
SCHEDULES FOR ALL PROPOSED EQUIPMENT, PANELS, CONDUCTORS, FIXTURES, ETC.
LIGHTING, FIRE ALARM/MASS COMMUNICATIONS, LOW VOLTAGE SYSTEMS, COMMUNICATION SYSTEMS, LIGHTNING PROTECTION SYSTEMS, GROUNDING SYSTEMS
ALL PHOTOMETRIC CALCULATIONS IN PLAN VIEW.
Last Updated: 24 June 2014
UNCLASS//FOUO
UNCLASS//FOUO
SUBFACTOR 3 (CONT)
PLANS
** EXCEPTION **
ASBESTOS / LEAD BASED PAINT ABATEMENT DESIGN WILL NOT BE REQUIRED
ASBESTOS/LBP ABATEMENT WILL BE INCLUDED IN PRICING USING THE ASSUMPTIONS PROVIDED IN SOW
Last Updated: 24 June 2014
UNCLASS//FOUO
UNCLASS//FOUO
SUBFACTOR 4
LIST OF DESIGN CRITERIA
PROVIDE A DETAILED LIST OF APPLICABLE DESIGN CRITERIA USED IN DESIGN
REFERENCE IS TO BE SPECIFIC
EXAMPLE
UFC 3-520-05, STATIONARY BATTERY AREAS
PARAGRAPH 2-4.5 Illuminance levels in the battery room shall be designed to meet IESNA Lighting Handbook recommendations with a minimum illumination level of 300 lux (30 fc). The lighting design shall consider the type of battery rack and the physical battery configuration to ensure that all points of connection, and maintenance and testing are adequately illuminated.
To receive an "acceptable" rating, the contractor must list applicable codes and demonstrate compliance with the applicable codes and guidance.
Last Updated: 24 June 2014
UNCLASS//FOUO
UNCLASS//FOUO
SUBFACTOR 5
DESIGN CALCULATIONS
HVAC HEATING / COOLING LOAD CALCS
VENTILATION CALCULATIONS
EXHAUST FAN VOLUMES
ELECTRICAL LOAD CALCULATIONS
EASY POWER CALCULATIONS
RISER DIAGRAMS AND CALCS
PANEL LOAD CALCS
To receive an "acceptable" rating, the contractor's design calculations must include HVAC load, exhaust fan volumes, electrical loads, easy power, riser calculations, and panel load calculations.
Last Updated: 24 June 2014
UNCLASS//FOUO
UNCLASS//FOUO
SUBFACTOR 6
SCHEDULE
PROVIDE GANTT CHART WITH PROPOSED WORK SCHEDULE
**NOTE** H3 WORK MUST OCCUR FIRST
To receive an "acceptable" rating, the chart must be complete, show a logical sequence of events, and complete design and construction within the allotted schedule.
Last Updated: 24 June 2014
UNCLASS//FOUO
UNCLASS//FOUO
SUBFACTOR 7
MATERIALS / EQUIPMENT LIST
PROVIDE LIST OF MATERIALS / EQUIPMENT EXCEEDING $3K
PROVIDE CUT SHEETS (IF AVAILABLE)
PAY ATTENTION TO AF 66 THAT IDENTIFIES ITEMS TO BE SUBMITTED WITH 65% DESIGN
To receive an "acceptable" rating, the list must be complete and all items shall meet design requirements and the MacDill Design Guide.
Last Updated: 24 June 2014
UNCLASS//FOUO
QUESTIONS
Last Updated: 24 June 2014
IRP SITE
HANGAR 3
HANGAR 1
Last Updated: 24 June 2014
UNCLASS//FOUO
ROOM 106 FIRST FLOOR H-1
Last Updated: 24 June 2014
UNCLASS//FOUO
ROOM 103 FIRST FLOOR H-1
Last Updated: 24 June 2014
UNCLASS//FOUO
ROOMS 161-167, FIRST FLOOR H-3
Last Updated: 24 June 2014
UNCLASS//FOUO
UNCLASS//FOUO
image3.jpeg image4.jpeg image5.png image6.png image7.png image8.png image9.emf image10.png image11.png image12.emf image13.emf image14.png image15.png image16.png image17.png image18.png image19.png image20.png image21.png image22.jpeg image23.jpeg image24.jpeg image25.jpeg image26.jpeg image27.jpeg image28.jpeg image29.jpeg image30.jpeg image31.jpeg image32.jpeg image33.jpeg image2.jpeg image1.png