05 AF Form 66 Schedule of Materials Submittals.pdf
PDF 138 KB Posted
- Attached to
- Child Development Center Renovation Solicitation
- Solicitation number
- FA452824R0001
About this file
This document is a schedule of materials submittals for the federal contract opportunity to renovate Child Development Center B164 at an Air Force base. It lists 101 line items specifying the required submittals for products and services, including shop drawings, samples, warranties, test reports and other documentation. Submittals are due by the dates indicated and must be approved by the project engineer and contracting officer. The renovation work includes asbestos and lead remediation, structural and architectural work, mechanical, electrical and plumbing systems upgrades. The solicitation was issued by the Department of the Air Force Global Strike Command for the renovation of the Child Development Center located at an Air Force base.
View the file
Other files
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SCHEDULE OF MATERIALS SUBMITTALS Project Number Solicitation/Contract Number
TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACT ADMINISTRATOR
Number of Copies Required
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
O F
C
M P
L
IA
N C
E
S H
O P
D R
A W
IN
G
S
S A
M P
L E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
F A
C T
U R
E R
'S
E
C O
M M
E N
D A
T
IO
N S
M A
N U
F A
C T
U R
E
W A
R R
A N
T Y
C A
T A
L O
G D
A T
A
O P
E R
A T
IN
G
S
T R
U C
T
IO
N S
T E
S T
S
O T
H E
R
R E
Q U
IR
E
D S
U B
M
IS
S
IO
N
D
T E
D A
T E
R E
C E
IV
E
D I
N T
R A
C T
IN
G
D A
T E
T O
C
IV
IL
G
IN
E E
R
IN
G
R E
T U
R N
S U
S P
E N
T E
S U
B M
IT
T
A L
N U
M B
E R
S
C O
N T
R A
C T
S U
B M
IT
T
L
A L
A P
P R
O V
A L
REMARKS
07 02 04 04 08 11 03 10 06 01, 05, 09
APPROVED DISAPPROVED
Section 01 11 00 - Summary of
Work X
Section 01 30 00 - Adminstrative
Requirements X
Section 01 32 01.00 10 - Project
Schedule X
Section 01 33 00 - Submittal
Procedures X
Section 01 33 29 - Sustainability
Reporting X X
Section 01 35 26 - Government
Safety Requirements
Section 01 45 00.10 20 - Quality
Control for Minor Construction X
8 01 45 35 - Special Inspections X X X X
01 50 00 - Temporary Construction
Facilities and Controls X X
Section 01 57 19 - Temporary
Environmental Controls X X X X
Section 01 74 19 - Construction
Waste Management and Disposal X X X
Section 01 78 00 - Closeout
Submittals X X X X
Section 01 78 23 - Operation and
Maintenance Data X X
Section 01 78 39 - As-Built
Drawings X X
01 91 00.15 - Total Building
Commissioning X X X X X
02 41 00 - Demolition and
Deconstruction X X X
Project Title:
AFPID 1027005 Renovate CDC B164 - 2
DATE CONTRACTOR NOTIFIED
Number of Copies Required
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
M P
L
IA
N C
E
S H
O P
D R
A W
IN
G
S
S A
M P
L E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
F A
C T
U R
E
C O
M M
E N
D A
T
IO
N S
M A
N U
F A
C T
U R
E
R R
A N
T Y
C A
T A
L O
G D
A T
A
O P
E R
A T
T R
U C
T
IO
N S
T E
S T
S
O T
H E
R
R E
Q U
IR
E
D S
U B
M
IS
S
T E
D A
T E
R E
C E
IV
E
D
N T
R A
C T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
S P
E N
T E
S U
B M
IT
T
A L
N U
M B
E R
S
C O
N T
R A
C T
S U
B M
IT
T
A L
A P
P R
O V
A L
REMARKS
07 02 04 04 08 11 03 10 06 01, 05, 09
APPROVED DISAPPROVED
Project Title:
AFPID 1027005 Renovate CDC B164 - 2
DATE CONTRACTOR NOTIFIED
17 02 82 00 - Asbestos Remediation X X X X
18 02 83 00 - Lead Remediation X X X X X
02 84 00 - Handling of Lighting
Ballasts and Lamps Containing
PCBs and Mecury
X X
03 30 53 - Miscellaneous Cast-in-
Place Concrete X X X X X
21 04 20 00 - Unit Masonry X X X X X X X
22 05 12 00 - Structural Steel X X X X X
23 05 30 00 - Steel Decks X X X X X
05 50 13 - Miscellaneous Metal
Fabrications X
25 06 10 00 - Rough Carpentry X X X
06 41 16.00 10 - Plastic-Laminate-
Clad Architectural Cabinets X X X X
06 61 16 - Solid Surfacing
Fabrications X X X X X
07 21 13 - Board and Block
Insulation X X X
07 21 16 - Mineral Fiber Blanket
Insulation X X X
07 27 26 - Fluid-Applied
Membrane Air Barriers X X X X X X
31 07 27 36 - Spray Foam Air Barriers X X X X X X
32 07 42 13 - Metal Soffit Panels X X X X X X X X
07 53 23 - Ethylene-Propylene-
Diene-Monomer Roofing X X X X X
07 60 00 - Flashing and Sheet
Metal X X X X
35 07 84 00 - Firestopping X X X X
36 07 92 00 - Joint Sealants X X X
Number of Copies Required
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
M P
L
IA
N C
E
S H
O P
D R
A W
IN
G
S
S A
M P
L E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
F A
C T
U R
E
C O
M M
E N
D A
T
IO
N S
M A
N U
F A
C T
U R
E
R R
A N
T Y
C A
T A
L O
G D
A T
A
O P
E R
A T
T R
U C
T
IO
N S
T E
S T
S
O T
H E
R
R E
Q U
IR
E
D S
U B
M
IS
S
T E
D A
T E
R E
C E
IV
E
D
N T
R A
C T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
S P
E N
T E
S U
B M
IT
T
A L
N U
M B
E R
S
C O
N T
R A
C T
S U
B M
IT
T
A L
A P
P R
O V
A L
REMARKS
07 02 04 04 08 11 03 10 06 01, 05, 09
APPROVED DISAPPROVED
Project Title:
AFPID 1027005 Renovate CDC B164 - 2
DATE CONTRACTOR NOTIFIED
08 11 13 - Steel Doors and
Frames X X
08 31 00 - Access Doors and
Panels X X X
08 41 13 - Aluminum-Framed
Entrances and Storefronts X X X X X X X
40 08 71 00 - Door Hardware X X X X
41 08 81 00 - Glazing X X X X X
09 22 00 - Supports for Plaster and Gypsum Board X X
43 09 29 00 - Gypsum Board X X X X
09 30 10 - Ceramic, Quarry, and
Glass Tiling X X X X
45 09 51 00 - Acoustical Ceilings X X X X X
46 09 65 00 - Resilient Flooring X X X X X X X
09 67 23.13 - Standard Resinous
Flooring X X X X X X
09 67 23.15 - Fuel Resistive
Resinous Flooring, 3-Coat System X X X X X
49 09 68 00 - Carpeting X X X X X X X
50 09 90 00 - Paints and Coatings X X X X X X
51 10 11 00 - Visual Display Units X X X
52 10 14 00.10 - Exterior Signage X X X X
53 10 14 00.20 - Interior Signage X X X X
54 10 21 13 - Toilet Compartments X X X X X
10 26 00 - Wall and Door
Protection X X X X
56 10 28 13 - Toilet Accessories X
57 12 24 13 - Roller Window Shades X X X X X X X X
21 13 13 - Wet Pipe Sprinkler
System, Fire Protection X X X X X X X
Number of Copies Required
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
M P
L
IA
N C
E
S H
O P
D R
A W
IN
G
S
S A
M P
L E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
F A
C T
U R
E
C O
M M
E N
D A
T
IO
N S
M A
N U
F A
C T
U R
E
R R
A N
T Y
C A
T A
L O
G D
A T
A
O P
E R
A T
T R
U C
T
IO
N S
T E
S T
S
O T
H E
R
R E
Q U
IR
E
D S
U B
M
IS
S
T E
D A
T E
R E
C E
IV
E
D
N T
R A
C T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
S P
E N
T E
S U
B M
IT
T
A L
N U
M B
E R
S
C O
N T
R A
C T
S U
B M
IT
T
A L
A P
P R
O V
A L
REMARKS
07 02 04 04 08 11 03 10 06 01, 05, 09
APPROVED DISAPPROVED
Project Title:
AFPID 1027005 Renovate CDC B164 - 2
DATE CONTRACTOR NOTIFIED
22 00 00 - Plumbing, General
Purpose X X X X X
23 05 48.00 40 - Vibration and
Seismic Controls for HVAC Piping and Equipment
X X X
61 23 05 48.19 - Bracing for HVAC X X X
23 05 93 - Testing, Adjusting, and
Balancing for HVAC X X X X X
23 07 00 - Thermal Insulation for
Mechanical Systems X X X X X
23 08 00.00 20 - Commissioning of
Mechanical and Plumbing
Systems
X X
23 09 00 - Instrumentation and
Control for HVAC X X X X X
66 23 11 20 - Facility Gas Piping X X X X X X
23 21 13.00 20 - Low Temperature
Water (LTW) Heating Systems X X X X X
68 23 21 23 - Hydronic Piping X X X X X
69 23 23 00 - Refrigerant Piping X X X X X
23 25 00 - Chemical Treatment of
Water for Mechanical Systems X X
71 23 30 00 - HVAC Air Distribution X X X X X X X
72 23 52 00 - Heating Boilers X X X X X X
23 64 26 - Chilled, Chilled-Hot, and Condenser Water Piping
Systems
X X X X X
23 81 00.00 20 - Unitary Air
Conditioning Equipment X X X X X X X
23 81 47 - Water-Loop and
Ground-Loop Heat Pump Systems X X X X X X X
Number of Copies Required
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
M P
L
IA
N C
E
S H
O P
D R
A W
IN
G
S
S A
M P
L E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
F A
C T
U R
E
C O
M M
E N
D A
T
IO
N S
M A
N U
F A
C T
U R
E
R R
A N
T Y
C A
T A
L O
G D
A T
A
O P
E R
A T
T R
U C
T
IO
N S
T E
S T
S
O T
H E
R
R E
Q U
IR
E
D S
U B
M
IS
S
T E
D A
T E
R E
C E
IV
E
D
N T
R A
C T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
S P
E N
T E
S U
B M
IT
T
A L
N U
M B
E R
S
C O
N T
R A
C T
S U
B M
IT
T
A L
A P
P R
O V
A L
REMARKS
07 02 04 04 08 11 03 10 06 01, 05, 09
APPROVED DISAPPROVED
Project Title:
AFPID 1027005 Renovate CDC B164 - 2
DATE CONTRACTOR NOTIFIED
23 82 00.00 20 - Terminal Heating
Unit X X X
25 05 11 - Cybersecurity for
Facility-Related Control Systems X X X X X
26 20 00 - Interior Distribution
System X X X X X X
26 28 01.00 10 - Coordinated
Power System Protection X
26 29 23 - Adjustable Speed Drive
(ASD) Systems Under 600 Volts X X X X X X
26 42 13 - Galvanic (Sacrificial)
Anode Cathodic Protection
(GACP) System
X X X X X X
82 26 51 00 - Interior Lighting X X X X X
83 26 56 00 - Exterior Lighting X X X X X
27 10 00 - Building
Telecommunications Cabling
System
X X X X X X X
27 51 23 - Intercommunication
System
28 08 10 - Electronic Security
System Acceptance Testing X X X
28 10 05 - Electronic Security
System (ESS) X X X X X X
28 31 76 - Interior Fire Alarm and
Mass Notification System X X X X X X X
89 31 00 00 - Earthwork X X X X
31 05 19.13 - Geotextiles for
Earthwork X X
91 31 11 00 - Clearing and Grubbing X
32 01 19.61 - Sealing of Joints in
Rigid Pavement X X X X X
Number of Copies Required
L
IN
E N
U M
B E
R
ITEM OR DESCRIPTION OF ITEM, CONTRACT
REFERENCE, TYPE OF SUBMITTAL
C E
R T
IF
IC
A T
IO
N
M P
L
IA
N C
E
S H
O P
D R
A W
IN
G
S
S A
M P
L E
S
C O
L O
R S
E L
E C
T
IO
N
M A
N U
F A
C T
U R
E
C O
M M
E N
D A
T
IO
N S
M A
N U
F A
C T
U R
E
R R
A N
T Y
C A
T A
L O
G D
A T
A
O P
E R
A T
T R
U C
T
IO
N S
T E
S T
S
O T
H E
R
R E
Q U
IR
E
D S
U B
M
IS
S
T E
D A
T E
R E
C E
IV
E
D
N T
R A
C T
IN
G
D A
T E
T O
C
G
IN
E E
R
IN
G
R E
T U
R N
S U
S P
E N
T E
S U
B M
IT
T
A L
N U
M B
E R
S
C O
N T
R A
C T
S U
B M
IT
T
A L
A P
P R
O V
A L
REMARKS
07 02 04 04 08 11 03 10 06 01, 05, 09
APPROVED DISAPPROVED
Project Title:
AFPID 1027005 Renovate CDC B164 - 2
DATE CONTRACTOR NOTIFIED
32 11 20 - Base Course for Rigid and Subbases for Flexible
Pavements
X
32 12 13 - Bituminous Tack and
Prime Coats X
32 12 16.16 - Road-Mix Asphalt
Paving X X X X
32 16 19 - Concrete Curbs, Gutters and Sidewalks X X
32 31 13 - Chain Link Fences and
Gates X X X X X
98 32 92 19 - Seeding X X X
33 11 00 - Water Utility Distribution
Piping X X X X X
100 33 30 00 - Sanitary Sewer X X X X X
33 71 02 - Underground Electrical
Distribution X X
PREVIOUS EDITION IS OBSOLETE.
MATERIAL APPROVAL SUBMITTAL
(See Instructions on Reverse)
TO: (Contracting Officer)
PROJECT NUMBER
FOR GOVERNMENT USE ONLY
Public reporting burden for this collection of information is estimated to average 20 minutes per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden to the Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, Arlington VA 22202-4302, and to the Office of Management and Budget, Paperwork Reduction Project OMB No 9000-0062, Washington DC 20503.
Please DO NOT RETURN your form to either of these addresses. Send your completed form to: SAF/AQCO, Pentagon, Washington DC 20330-1000.
FROM: (Contractor)
DATE
For Evaluation and Action
TO: (Base Civil Engineering Officer)
TYPE OR PRINT NAME AND GRADE
SIGNATURE
TO: (AF Contracting Office)
RECOMMEND APPROVAL DISAPPROVAL AS INDICATED ABOVE AND SUBJECT TO ANY APPLICABLE COMMENTS ON THE REVERSE
APPROVED
DISAPROVED AS INDICATED ABOVE AND SUBJECT TO ANY APPLICABLE COMMENTS ON THE REVERSE SIDE. REQUEST
TO: (Contractor)
DATE TYPE OR PRINT NAME AND GRADE SIGNATURE
DATE
DATE TYPE OR PRINT NAME AND GRADE SIGNATURE
AF FORM 3000, SEP 91 (EF)
SUBMITTALSUBMISSION NUMBER
CONTRACT NUMBER
NEW RESUBMITTAL
PREVIOUS SUBMISSION NUMBER
ITEM
NO.
SPECIFICATION SECTION/
PARA NO./DRAWING NO.
DESCRIPTION OF MATERIAL
(Include Type, Model Number, Catalog Number, Mfg., etc.)
SEE
REVERSE INITIAL
BY COMPLETING THIS FORM, THE UNDERSIGNED CONTRACTOR CERTIFIES THAT
THE MATERIAL COMPLIES WITH ALL SPECIFICATIONS OF SUBJECT CONTRACT.
AP-
PROVED
DISAP-
PROVED
TO BE COMPLETED BY CONTRACTOR
DATE TYPE OR PRINT NAME AND TITLE
SIGNATURE
FOR GOVERNMENT USE ONLY
Form Approved OMB No 9000-0062 Expires Apr 30, 1993
RESUBMITTAL ON DISAPPROVED ITEMS WITHIN DAYS OF DATE SHOWN BELOW.
File details come from the government source that posted it. Updated .