This federal solicitation is seeking construction services for the establishment of NAVAIDS facilities at O'Hare International Airport in Chicago, Illinois. The services include providing all labor, materials, equipment, and supervision to construct new facilities in accordance with drawings and specifications. The estimated price range for the project is $5-10 million. Interested firms must have experience on similar airport projects both in size and complexity. The performance period is 605 calendar days starting November 15, 2020. Offers are due by October 7, 2020 and must include documentation of relevant past performance, insurance, bonding capacity, and a small business subcontracting plan. The soliciting agency is the Department of Transportation Federal Aviation Administration Southwestern Region.
View the file
Other files
Show 40 more
Latest 50 of 158 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
o rd -d -l o c l-c .d g n
/2
/2
:4
:2
P
M G re g o ry C
T R S p e n c e r
A
B
C
D
E
F
G
H
8 7 6 5 4 3 2 1
H
G
F
E
D
C
12345678
REVDRAWING NO
DATE JCN
APPROVED BY
ISSUED BY
CHECKED
DRAWN
DESIGNED
SUBMITTED BY
REVIEWED BY
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV
DATE
APPROVED
DESCRIPTION JCN
DATE
REDLINE
APVD
A
9-WAY 5" CECO DUCTBANK
EM-OH6144.200.420-02
EM-OH6144.200.420-01
EM-OH6144.200.420-03
CE-OH6144.200.420-03
.0
CB-H6133.331-409
18"
E L
V
E L
V
E L
V
E L
V
E L
V
E L
V
E L
V
E L
V
E L
V
E L
V
E L
V
COMM
HV
E L
V
E L
V
E L
V
E L
V
E L
V
E L
V
E L
V
E L
V
E L
V
E L
V
EM-OH6144.200.420-74
EH-OH6144.200.420-66
EH-OH6144.200.420-65
EH-OH6144.200.420-69
EH-OH6144.200.420-56EH-OH6144.200.420-52
EH-OH6144.200.420-54
EH-OH6144.200.420-53
EH-OH6144.200.420-55
EH-OH6144.200.420-50
EH-OH6144.200.420-51
LOCALIZER
FFM
IM
EH-OH6144.200.420-73
200.420-68
EM-OH6144.
200.420-71
EH-OH6144.
200.420-72
EH-OH6144.
.200.420-70
EM-OH6144
FFM
200.420-78
EH-OH6144.
200.420-67
EH-OH6144.
VB-0H6134.710.371.106
FH-0H6134.710.371.107
LOCALIZER SHELTER
ALSF-2 /
LOCATION FOR THE
BUILDING
IN FUTURE
CONTINUATION
4(4") FAA-SEC
4 (4") COMm
8-WAY- 4"CED
COMM
LV
COMM
COMM
HV
COMM
HV
LV
COMM
LV
COMM
MH-OH6143.710.371-05
CB-H6133.331-410
FH-0H6134.710.371.108
COMM
HV
COMM
LVHV
COMM
HV
CE-OH6144.200.420-01
CE-OH6144.200.420-02
HV
LV
LV
COMM
HV
H V L V
COMM
COMM
HV
LV
HV
COMM
HV
LV
COMM
HV
LV
COMM
HV
LV
COMM
LV
COMM
HV
LV
LV
HV
COMM
HV
HV HVHV
LV
HV
ATT - 12(4")
COMM - 6(4")
MH-OH6143.710.371-06
CB-OH6143.710.371-07
1-12’x8’ BOX CULVERT
CE OH 6134.710.371.113
COMM - 6(4")
ATT - 12(4")
CB-OH6143.710.371-02
MH-OH6143.710.371-02
MH-OH6143.710.371-03
CB-OH6143.710.371-04
MH-OH6143.710.371-01
MH-H6133.331-404
60" RCP
FH-0H6134.710.371.106
T OH 6134.200.420.107 (TFR)
MH-OH6143.710.371-07
CB-OH6143.710.371-08
ATT - 12(4")
CE OH 6134.710.371.111
COMM - 6(4")
LOCALIZER CRITICAL AREA
EH-OH6144.200.420-79
CE OH 6134.710.371.112
EH-OH6144.200.420-75
6 (2") POWER
6-WAY- FAA
18"
H
H
H H
H
H
H
H
H
H
H
H
H
H
H
H
2 (2") COM-FL
2 (2") LV-FL
6 (2") HV-ALSF
10-WAY-2" FAA
DUCTBANK BY OTHERS.
DUCTBANK.
CONCRETE ENCASED
GROUND IN 2" PVC
AND 1-1/C #6 GREEN
5/8" HELIAX CABLE
INSTALL
& SUPPORT
FFM ANTENNA
INSTALL
NEMA 4X
CBL. JCT. BOX
12"X16"X6" D
INSTALL
1083.71’
(24" DEEP)
#4/0 BARE
E D
M
IS
S
U E
D F
O R
NAVAIDS
IL
10/31/2019 1898272
ORD-D-LOC27L-C007
C O
N S
T R
U C
T
IO
N
ENGINEERING SERVICES
LOC
CHICAGO O’HARE INTERNATIONAL AIRPORTCHICAGO
PROJECT ENGINEER MGR: ENGINEERING
THIS DRAWING PRODUCED ON THE AGL REGION MICROSTATION SYSTEM
ATO - TECHNICAL OPERATIONS CENTRAL SERVICE AREA
o rd -d -l o c l-c .d g n
SITE PLAN
NOTES:
ITEMS APPLY
ONLY CLOUDED
LKN
ABANDON IN PLACE
FENCE
WATER DISTRIBUTION
TELEPHONE
COMED DUCTBANK
FUELING FACILITIES
NATURAL GAS
AND REMOVE)
DEMO (DEMOLISH
CATCH BASIN
DRAINAGE MANHOLE
FIRE HYDRANT
ELECTRICAL HANDHOLE
MANHOLE
MJ GATE VALVE
SANITARY SEWER
STORM SEWER
PIPE UNDERDRAIN
DUCTBANK
COMMON ELECTRICAL
SANITARY MANHOLE
COMED/AT&T MANHOLES
AIRFIELD ELECTRIC
MANHOLE CLUSTER
FAA, COMM, AIRFIELD
FAA DUCTBANK
STRUCTURE AND BASE
ALSF-2 ELEVATED LIGHT
SEQUENCED FLASHER
AND BASE WITH
LIGHT STRUCTURE
ALSF-2 APPROACH
TSA = TAXIWAY SAFETY AREA
RSA = RUNWAY SAFETY AREA
ABBREVIATIONS:
T
G
CECO
W
ST
SA
SD
F
FAA
CED
UTILITY LEGEND
CENTER OF DISTRIBUTION UNIT.
PLANE: 20’ AT LEAST. CONDUITS TO ROUTE INTO
ROUTED WITH VERY LONG SWEEPS IN THE HORIZONTAL
ALL CONDUITS WITH HELIAX CABLES MUST BE 5.
FOUNDATION BY OTHERS.
LOCALIZER ANTENNA INSTALLATION DETAILS.
SEE SHEETS ORD-D-LOC27L-C001 THRU C006 FOR 4.
DETAILS. FOUNDATION BY OTHERS.
SEE SHEET ORD-D-IM27L-C001 (FFM) INSTALLATION3.
PROPER INSTALLATION OF ALL FACILITIES.
COORDINATE WITH CITY CONTRACTOR TO INSURE2.
TERMINATE CONDUITS, INSTALL ANTENNAS.
BY OTHERS. FAA CONTRACTOR TO PULL CABLES
FFM & LOC FOUNDATIONS ARE CONSTRUCTED
THE ALSF LIGHT LANE, ALL DUCT BANKS, ROADS1.
ELV
ELV
FAR-FIELD MONITOR - RUNWAY 27L
| 2020-07-06T09:45:19-0500 | |
| RAFAEL CRAME |
| 2020-07-09T16:38:13-0500 | |
| LUIS N DOMINGUEZ |