About this file

This solicitation is for construction services for the establishment of NAVAIDS facilities serving extended Runway 9R-27L at O'Hare International Airport in Chicago, Illinois. The contractor shall provide all labor, materials, and equipment to perform the project in accordance with contract clauses, drawings, and specifications. The performance period is 605 calendar days, with an anticipated start date of November 15, 2020. The estimated price range for this procurement is $5 million to $10 million. Interested firms must have successfully completed similar projects both in dollar amount and scope of work at an operational airport. Offers must be submitted by October 7, 2020. Offerors must include a cover letter, signed solicitation and award forms, past experience references, a proposed construction schedule, financial capability documentation, liability insurance documentation, bonding confirmation, and a small business subcontracting plan. The soliciting agency is the Department of Transportation Federal Aviation Administration Southwestern Region.

View the file

Other files

File Type Posted
697DCK-20-R-00436 - Amendment 0001.pdf PDF
ord-d-als09r-e009.pdf PDF
ord-d-gs09r-c004.pdf PDF
ord-d-als09r-m001.pdf PDF
ord-d-gs27l-c006.pdf PDF
ord-d-als27l-c007.pdf PDF
ord-d-ald09r-g024.pdf PDF
ord-d-ald09r-g015.pdf PDF
ord-d-gs27l-a001.pdf PDF
ord-d-ald09r-g008.pdf PDF
ord-d-gs27l-c003.pdf PDF
ord-d-als09r-e006.pdf PDF
ord-d-loc27l-c007.pdf PDF
ord-d-ald09r-g017.pdf PDF
ord-d-als27l-c006.pdf PDF
ord-d-als09r-c006.pdf PDF
ord-d-als27l-e006.pdf PDF
Attachment No. 12 - Required Checklist for Underground Storage Tank Installation.pdf PDF
ord-d-gs27l-e001.pdf PDF
ord-d-loc27l-c003.pdf PDF
ord-d-als09r-e005.pdf PDF
Attachment No. 20 - Past Performance Questionnaire.doc DOC document
ord-d-gs09r-a001.pdf PDF
ord-d-im09r-c001.pdf PDF
ord-d-als27l-e005.pdf PDF
ord-d-als27l-m002.pdf PDF
ord-d-als09r-e012.pdf PDF
ord-d-ald09r-g031.pdf PDF
ord-d-gs27l-c004.pdf PDF
ord-d-ald09r-g004.pdf PDF
ord-d-gs09r-c005.pdf PDF
ord-d-als27l-m003.pdf PDF
ord-d-als09r-c011.pdf PDF
ord-d-als09r-m004.pdf PDF
ord-d-loc09r-c003.pdf PDF
ord-d-ald09r-g022.pdf PDF
ord-d-gs27l-c005.pdf PDF
Attachment No. 18 - Contract Insurance Requirements - Chicago Department of Aviation.pdf PDF
ord-d-als27l-c012.pdf PDF
Attachment No. 02 - Special Specifications.pdf PDF
ord-d-ald09r-g014.pdf PDF
Attachment No. 14 - Ground Resistance Testing Form.xlsx XLSX spreadsheet
ord-d-ald09r-g002.pdf PDF
ord-d-als27l-c014.pdf PDF
Attachment No. 19 - Small Business Subcontracting Plan - 697DCK-20-R-00436.pdf PDF
697DCK-20-R-00436.pdf PDF
ord-d-loc27l-c004.pdf PDF
ord-d-loc09r-c002.pdf PDF
ord-d-als09r-e013-1.pdf PDF
Attachment No. 04 - Section L-110 - Installation of Airport Underground Electrical Duct.pdf PDF
Show 40 more

Latest 50 of 158 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

o rd -d -a ls r-e .d g n

/2

/2

:1

:0

P

M G re g o ry C

T R S p e n c e r

A

B

C

D

E

F

G

H

8 7 6 5 4 3 2 1

H

G

F

E

D

C

12345678

REVDRAWING NO

DATE JCN

APPROVED BY

ISSUED BY

CHECKED

DRAWN

DESIGNED

SUBMITTED BY

REVIEWED BY

FEDERAL AVIATION ADMINISTRATION

DEPARTMENT OF TRANSPORTATION

REV

DATE

APPROVED

DESCRIPTION JCN

DATE

REDLINE

APVD

A

DESCRIPTION

68’-0" LENGTH X 24’-0" WIDTH WOOD-FRAMED EQUIPMENT BUILDING

NATIONAL SAFETY, INC. CAT. NO. 618-8303X75 MEETS SPECIFICATIONS

SWITCHBOARD MATTING, 1/4" THICKNESS, CONFORMING TO ASTM D 178,

B-1

B-2

B-3

B-4

B-5

NO.

QTY

225 SF

REMARKS (SEE NOTE 1)

BARD NO. 8404-012 MEETS SPECIFICATIONS.

THERMOSTAT, BARD NO. 8403-021 WITH SUBBASE,

SG-3, RETURN GRILL RG-3, AND WALL-MOUNTED

NO. W30A2-A05WPXXXJ WITH SUPPLY REGISTER,

HVAC UNIT, THRU-WALL TYPE, BARD MODEL

QTY

HVAC-2

HVAC-1

MC-1

EF-1

BD-1

CD-1

CD-2

EUH-1

HVAC-3

ITEM

ROOM

REGULATOR

ROOM

REGULATOR

ROOM

E/G

ROOM

E/G

ROOM

E/G

ROOM

E/G

ROOM

LOCALIZER

LOCATION CFM

(IN WG)

EXT SP

N/A

17,180

N/A

N/A

1000 0.40

N/A

N/A

N/A

N/A

0.50

N/A

0.50

N/A

N/A

N/A

N/A

N/A

8.0

5 N/A N/A 22000 30000 N/A N/A 230 60 1 35 N/A N/A N/A N/A 1/3 1075

N/A1/100N/A

SENS VOLT HZ PH AMPS TYPE HP

42000 57500 230 60 1 60

120 60 1 CENT

240 1

TOTAL

1/3

1/3

EAT LAT EAT LAT FLA MCA MOP

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/AN/A N/AN/A N/A

N/AN/A N/A N/AN/AN/AN/AN/A

N/A N/A N/A N/A N/A N/A N/A N/AN/A N/A

N/AN/AN/AN/AN/AN/AN/AN/AN/AN/A

N/AN/AN/AN/AN/AN/AN/AN/AN/AN/A

N/AN/AN/AN/AN/AN/AN/A105

N/AN/A N/A

120 N/A

N/A

N/A

N/A

N/A

6060 34

N/AN/AN/AN/AN/AN/AN/AN/AN/AN/A 120 N/A N/AN/A60

HEATING

ELEC (KW)

FAN

RPM

N/A

N/A

N/A

N/A

ELECTRICAL DATACOOLING (BTU)

(SEE NOTE 1)

REMARKS

ACTUATOR, RUSKIN LBAR120-S.

MODEL CD60 WITH ELECTRIC DAMPER

CONTROL DAMPER, 28"W X 24"T RUSKIN

NO. GGD221.1U. NO SUBSTITUTIONS.

ACTUATOR, SIEMENS OPEN AIR MODEL

MODEL CD60 WITH ELECTRIC DAMPER

CONTROL DAMPER, 57-1/2"W X 44"T RUSKIN

ROOM

E/G

BE REQUIRED TO ACCESS THE CONTROLLER.

ACCESSIBLE ON FRONT OF THE UNIT. NO DOOR SHALL

PROVIDE TEMPERATURE CONTROL UNIT THAT IS

SURFACE MOUNTING FRAME, QMARK CAT. NO. EFQSM.

MOTOR, QMARK HEATER CAT. NO. EFQ8004, WITH

PERMANENTLY LUBRICATED TOTALLY ENCLOSED FAN

BUILT-IN POWER DISCONNECT SWITCH, 100 CFM

OVERHEAT PROTECTOR, BUILT-IN FAN DELAY SWITCH,

240V, 33.3A, WITH INTEGRAL THERMOSTAT, THERMAL

SURFACE-MOUNTED FAN-FORCED WALL HEATER, 8000W,

TO MEET THE SPECIFICATIONS.

BACKDRAFT DAMPER, BD-12 OR LATEST MODEL

SERIES, CATALOG NO. 120W17D WITH GRAVITY

FILTER ON THE ROOM SIDE OF THE DAMPER, ACW-B

LOREN COOK, SIDEWALL EXHAUSTER WITH INTERIOR

MERV-8 FILTER TO MEET THE SPECIFICATIONS.

PROVIDE FRONT LOADING TYPE FILTER RACK AND

INTERIORFILTER ON THE ROOM SIDE OF THE DAMPER.

MODEL BD6 OR LATEST MODEL WITH REMOVABLE

BACKDRAFT DAMPER, 60"W X 48"T, RUSKIN

OR LATEST MODEL TO MEET THE SPECIFICATIONS.

MASTER CONTROLLER, BARD MODEL NO. MC4000-BC

BRONZE FINISH, AS MANUFACTURED BY LITHONIA, PART NUMBER WSR-2SR3-120-PE-DDBXD

WALL MOUNTED LED EXTERIOR LIGHT FIXTURE WITH PHOTO CELL, STANDARD DARK

MEETS SPECIFICATIONS.

EXIT ILLUMINATED WITH LED LAMPS, EXITRONIX PART NUMBER CSX-2-3-1-3-W-EL2-G2

12 W, SEALED BEAM H.I.T. LAMPS, 90-MINUTE RUN TIME WITH 24-HOUR RECHARGE TIME,

EMERGENCY LIGHTING UNIT WITH STEEL HOUSING (CITY OF CHICAGO APPROVED), 6-VOLT,

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

TO MEET THE SPECIFICATIONS

BARD MODEL NO. W70A2-A10WPXXXJ OR LATEST MODEL

HVAC UNIT, THRU-WALL TYPE WITH ECONOMIZERS,

NOTES:

BUILDING SCHEDULE

MECHANICAL EQUIPMENT SCHEDULE

CAPABILITIES.

AND ECONOMIZER USAGE IN EMERGENCY VENTING SITUATIONS, WITH ETHERNET

POWER, LOW & HIGH TEMPERATURE, REFRIGERANT PRESSURE, CONTROLLER FAILURE

PROVIDE CONTROLLER THAT SHALL BE CAPABLE TO MONITOR FOR FIRE, LOSS OF

BOND UNITS TO EXTERNAL LIGHTNING PROTECTION SYSTEM.

(ONE DAY, ONE EVENING).

PROVIDE MINIMUM 2 CLASSES OF 8-HOURS EACH TRAINING FOR HVAC EQUIPMENT.

HVAC FILTERS TO BE MERV8 WASHABLE TYPE. WASH PRIOR TO B.O.D.

MAINTENANCE ACTIVITIES.

AND SHALL HAVE A MINIMUM OF 3’-0" CLEARANCE ON EACH SIDE TO ALLOW FOR

THE MOTOR SERVING THE DAMPER SHALL NOT BE INSTALLED WITHIN THE AIRFLOW

DEFINED TEMPERATURE.

OPERATE ONLY WHEN THE TEMPERATURE INSIDE THE ROOM GOES ABOVE AN FAA

FAN IS NOT TO OPERATE WHEN THE ENGINE GENERATOR IS RUNNING. IT SHOULD

COORDINATE WITH FAA FOR PROPER SEQUENCE OF OPERATION. THE EXHAUST

BE APPROVED BY THE FAA RESIDENT ENGINEER.

12 TONS OF FORCE CONCENTRICALLY APPLIED, PER FAA-STD-019F. THE TOOL SHALL

ALL CRIMPED CONNECTIONS SHALL BE ACCOMPLISHED WITH A TOOL PROVIDING

INCLUDE AN ARC FLASH WARNING DECAL PER NFPA 70, FAA ORDER 3900.64.

ENGINEER. IN ADDITION, EACH CONTRACTOR-FURNISHED ELECTRICAL ITEM SHALL

MAY BE EPOXY GLUED. COORDINATE EQUIPMENT LABELING WITH FAA RESIDENT

TO THE EQUIPMENT WITH AT LEAST TWO SCREWS, EXCEPT MAIN BREAKER PLATES

WITH 3/8-INCH MINIMUM HEIGHT LETTERS AND NUMERALS AND SHALL BE SECURED

BE NON-FERROUS METAL OR RIGID PLASTIC, STAMPED, EMBOSSED, OR ENGRAVED

PLATES ON ELECTRICAL EQUIPMENT OTHER THAN OUTLETS AND SWITCHES SHALL

ONE OR THREE PHASE AS APPLICABLE AND WHERE THE ITEM IS FED FROM. NAME

NAME, PANELBOARD AND CIRCUIT NUMBER OF THE UNIT, VOLTAGE UTILIZED,

LABELS THAT INDICATE ALL ELECTRICAL EQUIPMENT SHOWING THE FUNCTIONAL

ALL OF THE CONTRACTOR-FURNISHED ELECTRICAL ITEMS SHALL HAVE

MADE OF HIGH CONDUCTIVITY COPPER PER FAA-GL-918D.

ALL ELECTRICAL EQUIPMENT HAVING CURRENT CARRYING CAPACITY SHALL BE

LIGHTS NOT OVER DOORS DO NOT REQUIRE LIT "EXIT" SIGN.

EMERGENCY LIGHTS OVER DOORS SHALL HAVE A LIT "EXIT" SIGN. EMERGENCY

OTHERWISE NOTED.

ALL ITEMS ARE TO BE FURNISHED AND INSTALLED BY CONTRACTOR UNLESS

BAS-DBL 1 (LED DOUBLE BAY LIGHT).

PER SPECIFICATIONS. ACCEPTABLE FIXTURES:

120-VOLT, ALUMUNUM FINISH, 107 WATT,

4’-LONG 2-LAMP-TUBE L.E.D. LIGHT FIXTURE, SURFACE-MOUNTED,

E D

M

IS

S

U E

D F

O R

NAVAIDS

IL

10/31/2019 1898272

ORD-D-ALS09R-E008

C O

N S

T R

U C

T

IO

N

ENGINEERING SERVICES

ALS

RUNWAY 9R ALSF-2/27L LOCALIZER

EQUIPMENT SCHEDULES AND DESCRIPTIONS

CHICAGO O’HARE INTERNATIONAL AIRPORTCHICAGO

PROJECT ENGINEER MGR: ENGINEERING

THIS DRAWING PRODUCED ON THE AGL REGION MICROSTATION SYSTEM

ATO - TECHNICAL OPERATIONS CENTRAL SERVICE AREA

o rd -d -a ls r-e .d g n

2020-07-02T13:41:17-0500
RAFAEL CRAME
2020-07-09T14:21:15-0500
LUIS N DOMINGUEZ

File details come from the government source that posted it. Updated .