ord-d-als27l-c007.pdf
PDF 379 KB Posted
- Solicitation number
- 697DCK-20-R-00436
About this file
This federal solicitation requests offers for construction services to establish NAVAIDS facilities serving extended Runway 9R-27L at O'Hare International Airport in Chicago, Illinois. The contractor shall provide all labor, supervision, materials, and equipment to perform the project in accordance with drawings, specifications and a 605 calendar day performance period starting November 15, 2020. The estimated price range for this procurement is between $5 million and $10 million. Offerors must have experience on similar aviation projects and adhere to the specified construction schedule. Submissions are due October 7, 2020 and shall include past performance questionnaires, insurance documentation, bonding verification, and a small business subcontracting plan. The soliciting agency is the Department of Transportation Federal Aviation Administration Southwestern Region.
View the file
Other files
Show 40 more
Latest 50 of 158 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
o rd -d -a ls l-c .d g n
/2
/2
:2
:0
P
M G re g o ry C
T R S p e n c e r
A
B
C
D
E
F
G
H
8 7 6 5 4 3 2 1
H
G
F
E
D
C
12345678
REVDRAWING NO
DATE JCN
APPROVED BY
ISSUED BY
CHECKED
DRAWN
DESIGNED
SUBMITTED BY
REVIEWED BY
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV
DATE
APPROVED
DESCRIPTION JCN
DATE
REDLINE
APVD
A
TYP
TYP
TYP
TYP
7 TYP
6 TYP
TYP
DOWNSPOUT
TYP
3 2
9 9 8
3 12
TYP
HVAC-2 HVAC-1 TYP
TYP
19 19 19 19 19
CONTINUOUS RIDGE VENT
CONTINUOUS RIDGE VENT
H V
A C
H V
A C
H V
A C
C-18C-18
TYP.
ASTRAGAL (TYP.)
2’-6"13’-0"13’-0"13’-0"13’-0"13’-0"2’-6"
2’-0" MIN. (TYP)
SCALE: 1/4" = 1’-0"
SOUTH ELEVATION
SCALE: 1/4" = 1’-0"
SCALE: 1/4" = 1’-0"
EAST ELEVATION
WEST ELEVATION
SEE NOTE 12
04’ 4’ 8’
SCALE: 1/4" = 1’-0"
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
NOTES:
NUMBERED LEGEND:
15.
16.
DOOR. THE STAMP OR LABEL SHALL NOT BE PAINTED OVER.
INDICATED BY A STAMP OR METAL LABEL VISIBLE WHEN OPENING THE
DOORS AND DOOR FRAMES SHALL BE FIRE RATED. FIRE RATING SHALL BE
AS WELL AS AN EXTERIOR DOOR SWEEP WITH TRIM.
A TOE KICK SHALL BE PROVIDED ON THE INTERIOR SIDE OF THE DOOR,
INTERIOR AND EXTERIOR DOORS TO E/G ROOM ALONG WITH AN NFPA PLACARD.
CONTRACTOR SHALL PROVIDE A "HEARING PROTECTION REQUIRED" SIGN ON
DOWNSPOUTS SHALL BE BONDED TO THE LIGHTNING PROTECTION SYSTEM.
AND EXACT LOCATION WITH THE FAA R.E. (TYP 2 PLACES).
DENOTING THE FIRE DEPARTMENT BUILDING NUMBER. COORDINATE BUILDING NUMBER
CONTRACTOR SHALL PROVIDE AND INSTALL A SIGN ON THE BUILDING FACING ROAD APPROACH
COORDINATE SIGN SIZE, COLORING AND ROOM DESIGNATIONS WITH FAA RESIDENT ENGINEER.
ROOM. THE SIGN SHALL INCLUDE A COLOR REPRESENTATION OF THE FAA LOGO.
DESIGNATES THE ROOM’S USE, I.E., GENERATOR ROOM, LOCALIZER ROOM, EQUIPMENT
CONTRACTOR SHALL PROVIDE AND INSTALL A SIGN ON EACH EXTERIOR DOOR THAT
PROVIDED AT THE EXIT POINT OF THE DOWNSPOUT. SHALL NOT DRAIN ACROSS SIDEWALK.
CONTRACTOR SHALL INSTALL A MIDDLE GUTTER DOWNSPOUT. PROPER DRAINAGE SHALL BE
ON BOTH DOORS TO EG ROOM AND ON WALL NEAR TANK.
STORAGE TANK. COORDINATE EXACT LOCATION WITH FAA RESIDENT INSPECTOR.
CONTRACTOR TO FURNISH AND INSTALL 12"x12" NFPA PLACARD FOR UNDERGROUND
ALL EXTERIOR LIGHTS MUST BE LED TYPE WITH PHOTO CONTROL ONLY.
APPLY ANTI-SEIZE COMPOUND TO ALL THREADED EXTERIOR CONNECTIONS.
PROTECTION SYSTEM.
GUTTERS SHALL BE CONTINUOUS AND SEAMLESS AND MUST BE BONDED TO THE LIGHTNING
PROVIDE SNOW GUARDS ABOVE ALL EXTERIOR DOORS.
PROVIDE PIPE WITH EYEBOLT AND HASP FOR ALL EXTERIOR SERVICE DOORS.
6 BARE BONDED TO DOWN-CONDUCTORS.#VIA
BOND ALL EXTERIOR METALLIC ITEMS TO THE LIGHTNING PROTECTION SYSTEM
SEALER, EXTERIOR GRADE.
CONTRACTOR SHALL SEAL ALL PENETRATIONS THROUGH BUILDING WALLS WITH SILICONE
BOOK. SUBMIT SUBSTITUTIONS PER SPECIFICATIONS.
MANUFACTURER WITH A DETAILED LIST OF MATERIAL AND AN INSTALLATION INSTRUCTION
WARRANTY, PER SPECIAL SPECIFICATIONS. MATERIAL SHALL BE PROVIDED BY THE
TRIM SYSTEM SHALL BE FABRICATED BY ONE MANUFACTURER AS A COMPLETE SYSTEM, WITH
STANDING SEAM METAL ROOFING PANELS, SIDING PANELS, AND SOFFIT, FASCIA, AND
BLOCK (TYPICAL)
CONCRETE SPLASH
DOWNSPOUT WITH
FLIGHT CHECK ANTENNA
1 1/4" GRS MAST FOR
FURNISH AND INSTALL
PERSONNEL)
BY FAA INSTALLATION
(FURNISHED AND INSTALLED
FLIGHT INSPECTION ANTENNA
W/DAMPER, CD-2
INTAKE HOOD
60"W X 48"H
CD-1
W/DAMPER,
INTAKE HOOD
28"W X 4"H
FUEL TANK VENTS
DAY TANK AND U/G
RAIN CAP
E/G EXHAUST PIPE
STAINLESS STEEL
VENTILATION FAN, EF-1
SEE NOTE 9
NFPA PLACARD
BEYOND
HVAC-3
TO AVOID CONFLICTS (TYPICAL)
C-18 WITH INTERIOR EQUIPMENT
COORDINATE LOCATIONS OF UNIT
SEE NOTE 8
LIGHT, B-4 (TYPICAL)
EXTERIOR FLOOD
W/DAMPER, CD-1
INTAKE HOOD
28"W X 24"H
W/DAMPER, CD-2
INTAKE HOOD
60"W X 48"H
JUNCTION BOX
CONTROL WIRING
NEMA 3R
4" X 4" X 4"
CONDUIT. SEE NOTE 15
GROUND IN 3/4" LIQUID-TIGHT FLEXIBLE
6 INSULATED GREEN #6 AWG AND 1 #2
(STAINLESS STEEL)
HOOD W/DAMPER, BD-1
64"W X 52"H EXHAUST
GFI RECEPTACLE IN WATERPOOF HOUSING AND IN-USE COVER
DOOR SIGN, SEE NOTE 11
DISCONNECT SWITCH (UNIT C-18)
5" CONCRETE SPLASH BLOCK AND ROOF GUTTERING DOWNSPOUT
DOOR HOLDER STOP
DOOR HOLDERS WITH HOOK LATCH
SNOW GUARD ABOVE ALL EXTERIOR DOORS. (3 ROWS PER SMACA STANDARDS)
WHITE. PROVIDE SHOP DRAWINGS FOR SUBSTITUTION. SEE NOTE 1.
FASCIA SYSTEM FROM FABRAL MEETS SPECIFICATIONS. COLOR SHALL BE
20 YEAR WARRANTY ON FACTORY FINISH. DECOR-FLUSH METAL SOFFIT AND
PAINTED ALUMINIUM WITH HIDDEN FASTENERS, CONTINUOUSLY VENTED AND
YEAR WARRANTY ON FACTORY FINISH. SOFFIT SHALL BE HEAVY GAUGE
FASCIA MATERIAL SHALL BE 24 GA. STEEL WITH HIDDEN FASTENERS AND 20
SHOP DRAWINGS FOR SUBSTITUTION. COLOR SHALL BE WHITE. SEE NOTE 1.
STEEL AND NEOPRENE WASHER WITH COLOR TO MATCH PANEL. PROVIDE
SHEATHING USING STAINLESS STEEL SCREWS WITH A NO. 14 X 1" COMBINATION
FROM FABRAL MEETS SPECIFICATIONS. PANELS SHALL BE FASTENED TO
FADE AND CHALK WARRANTY. MIGHTI-RIB PBR METAL SIDING SYSTEM
10-YEAR WARRANTY AGAINST EDGE RUST AND ACID RAIN, AND 30-YEAR
STEEL, EXPOSED FASTENERS, LIFETIME FILM INTEGRITY WARRANTY.
STRUCTURAL EXPOSED FASTENER WALL SYSTEM, 26 GA., GRADE 80 KSI
INSTALLED OVER 3/4" SHEATHING.
SPECIFICATIONS. COLOR SHALL BE WHITE. PANELS SHALL BE
FROM FABRAL METAL WALL AND ROOFING SYSTEMS MEETS
ROOFING MATERIAL. SLIM SEAM METAL ROOFING (16" COVERAGE)
20 YEAR WARRANTY ON FACTORY FINISH, LIFETIME WARRANTY ON
STANDING SEAM METAL ROOFING SYSTEM, 24 GA., GRADE 40 STEEL,
BONDING STRAP, THOMPSON CAT. NO. 588, FROM DOOR FRAME TO DOOR.
4/0 AWG BARE COPPER PERIMETER GROUNDING CONDUCTOR, 30" BELOW GRADE.
FINISHED GRADE (MINIMUM).
3/4"X 10’ STAINLESS STEEL GROUNDING ELECTRODE, 12" BELOW
MIN 6’-0" ABOVE GRADE, CARRYING ROOF AND DOWN CONDUCTOR.
1" SCHEDULE 80 PVC CONDUIT FROM 12" BELOW GRADE TO
BONDED TO ROOF AND DOWN CONDUCTOR.
509X, CONNECTING PARALLEL CLAMP TO BONDING PLATE AT ITEMS TO BE
BONDING CONDUCTOR, 6 AWG BARE COPPER OR THOMPSON CAT. NO. 14X OR
TO ROOF AND DOWN CONDUCTOR.
PARALLEL CLAMP, THOMPSON CAT. NO. 565, CONNECTING BONDING CONDUCTOR
SHOWN. ITEMS NOT SHOWN BONDED DO NOT REQUIRE BONDING.
DOWN CONDUCTOR TO WALL-MOUNTED EQUIPMENT AND DOOR FRAME AS
TINNED BRONZE BONDING PLATE, THOMPSON CAT. NO. 702, BONDING ROOF AND
BASES TO ROOF WITH ROOF ADHESIVE THOMPSON CAT. NO. 731.
CAT. NO. 730 SPACED 30" O.C. MAXIMUM ON ROOF. FASTEN ADHESIVE POINT
STAMPED ADHESIVE CABLE HOLDER WITH BREAK-AWAY TABS, THOMPSON
ENCASED IN 1" DIA. SCHEDULE 80 PVC @ 12" BELOW GRADE, 8" MIN SWEEP RAD.
DIAGONALLY OPPOSITE BUILDING CORNERS. CONDUCTOR MUST BE
WELD BOTH ENDS OF THIS CONDUCTOR TO GROUNDING ELECTRODES AT
ROOF AND DOWN CONDUCTOR, THOMPSON CAT. NO. 32. EXOTHERMICALLY
ADHESIVE, M1 BY CHEMLINK.
THOMPSON CAT. NO. 71A. FASTEN ADHESIVE SADDLE TO ROOF WITH
AND ADAPTER THOMPSON CAT. NO. 665 AND ADJUSTABLE RIDGE SADDLE
LONG COPPER AIR TERMINAL WITH NICKEL-PLATED ROUNDED BLUNT TIP
AIR TERMINAL ASSEMBLY (5 REQUIRED) CONSISTING OF A 5/8" DIA X 12"
E D
M
IS
S
U E
D F
O R
NAVAIDS
IL
10/31/2019 1898272
ORD-D-ALS27L-C007
C O
N S
T R
U C
T
IO
N
ENGINEERING SERVICES
ALS
CHICAGO O’HARE INTERNATIONAL AIRPORTCHICAGO
PROJECT ENGINEER MGR: ENGINEERING
o rd -d -a ls l-c .d g n
THIS DRAWING PRODUCED ON THE AGL REGION MICROSTATION SYSTEM
ATO - TECHNICAL OPERATIONS CENTRAL SERVICE AREA
RUNWAY 27L ALSF-2/9R LOCALIZER
EXTERIOR ELEVATIONS
| 2020-07-02T13:52:02-0500 | |
| RAFAEL CRAME |
| 2020-07-09T14:58:52-0500 | |
| LUIS N DOMINGUEZ |
File details come from the government source that posted it. Updated .