About this file

This federal contract opportunity is for construction services for the establishment of NAVAIDS facilities serving extended Runway 9R-27L at O'Hare International Airport in Chicago, Illinois. The contractor shall provide all labor, materials, equipment, and supervision to perform the project in accordance with drawings, specifications, and contract clauses for an estimated price between $5 million to $10 million. The performance period is 605 calendar days with an anticipated start date of November 15, 2020. Offerors must have experience with similar airport projects and submit responses by October 7, 2020 including past performance, schedules, insurance documentation, and small business subcontracting plans for consideration. The soliciting agency is the Department of Transportation Federal Aviation Administration Southwestern Region.

View the file

Other files

File Type Posted
697DCK-20-R-00436 - Amendment 0001.pdf PDF
ord-d-als09r-e009.pdf PDF
ord-d-gs09r-c004.pdf PDF
ord-d-als09r-m001.pdf PDF
ord-d-gs27l-c006.pdf PDF
ord-d-als27l-c007.pdf PDF
ord-d-ald09r-g024.pdf PDF
ord-d-ald09r-g015.pdf PDF
ord-d-gs27l-a001.pdf PDF
ord-d-ald09r-g008.pdf PDF
ord-d-gs27l-c003.pdf PDF
ord-d-als09r-e006.pdf PDF
ord-d-loc27l-c007.pdf PDF
ord-d-ald09r-g017.pdf PDF
ord-d-als27l-c006.pdf PDF
ord-d-als27l-e006.pdf PDF
Attachment No. 12 - Required Checklist for Underground Storage Tank Installation.pdf PDF
ord-d-gs27l-e001.pdf PDF
ord-d-loc27l-c003.pdf PDF
ord-d-als09r-e005.pdf PDF
Attachment No. 20 - Past Performance Questionnaire.doc DOC document
ord-d-gs09r-a001.pdf PDF
ord-d-im09r-c001.pdf PDF
ord-d-als27l-e005.pdf PDF
ord-d-als27l-m002.pdf PDF
ord-d-als09r-e012.pdf PDF
ord-d-ald09r-g031.pdf PDF
ord-d-als09r-e008.pdf PDF
ord-d-gs27l-c004.pdf PDF
ord-d-ald09r-g004.pdf PDF
ord-d-gs09r-c005.pdf PDF
ord-d-als27l-m003.pdf PDF
ord-d-als09r-c011.pdf PDF
ord-d-als09r-m004.pdf PDF
ord-d-loc09r-c003.pdf PDF
ord-d-ald09r-g022.pdf PDF
ord-d-gs27l-c005.pdf PDF
Attachment No. 18 - Contract Insurance Requirements - Chicago Department of Aviation.pdf PDF
ord-d-als27l-c012.pdf PDF
Attachment No. 02 - Special Specifications.pdf PDF
ord-d-ald09r-g014.pdf PDF
Attachment No. 14 - Ground Resistance Testing Form.xlsx XLSX spreadsheet
ord-d-ald09r-g002.pdf PDF
ord-d-als27l-c014.pdf PDF
Attachment No. 19 - Small Business Subcontracting Plan - 697DCK-20-R-00436.pdf PDF
697DCK-20-R-00436.pdf PDF
ord-d-loc27l-c004.pdf PDF
ord-d-loc09r-c002.pdf PDF
ord-d-als09r-e013-1.pdf PDF
Attachment No. 04 - Section L-110 - Installation of Airport Underground Electrical Duct.pdf PDF
Show 40 more

Latest 50 of 158 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

o rd -d -a ls r-c .d g n

/2

/2

:2

:5

A

M G re g o ry C

T R S p e n c e r

A

B

C

D

E

F

G

H

8 7 6 5 4 3 2 1

H

G

F

E

D

C

12345678

REVDRAWING NO

DATE JCN

APPROVED BY

ISSUED BY

CHECKED

DRAWN

DESIGNED

SUBMITTED BY

REVIEWED BY

FEDERAL AVIATION ADMINISTRATION

DEPARTMENT OF TRANSPORTATION

REV

DATE

APPROVED

DESCRIPTION JCN

DATE

REDLINE

APVD

A

2" (TYP)

2" (TYP)

FLOOR SLAB

3/4" (TYP)

CHAMFER

ANCHOR

HOUSEKEEPING PAD

WWF 6X6X6/6

(TYP)

ANCHOR

AS SHOWN ON PLANS)

(SIZE AND NUMBER

CONDUIT STUBS

VERIFY DIMENSIONS

EQUIPMENT

ELECTRICAL

POWER CABLES, 5’-0" LONG

8" SQUARE DUCT FOR

C-7

C-6

C-5

C-1

A-23R

C-10

C-9

C-11

9" 8" 1’-0" 9"10"1’-2"

2’-0" 1’-0" 9" 9" 9" 9"1’-9"2’-1" 9" 2’-8" 1’-0"1’-8"2’-1" 9" 2’-3" 6"6"6"6"

(5" SP)

1’-0"

4"x4"

T-2

B-5

2" CONDUIT TOFLASHERS

TO

ON REAR WALL

SQUARE DUCT

2" CONDUIT TO

TO A-23E

2" CONDUIT

CABLE JUNCTION BOX, E-9

2" CONDUIT TO CONTROL

2" CONDUIT

2" CONDUIT TO

CCR NO. 1 THRU CCR NO. 5

UNISRUT (TYP)

GALVANIZED

P1000

C-2

C-8

C-8A

C-12

FE

4" CONDUIT

CAUTION

DANGER

MAIN GROUNDING PLATE

ELECTRONIC

CAUTION

EXIT

A

NOT TO SCALE

SECTION

E231A NOT TO SCALE

HOUSEKEEPING PAD

PLAN

ELEVATION

SCALE: 1/2" = 1’-0"

A

NORTH WALL OF REGULATOR ROOM

2" EMT (TYP)

2’-6"2’-0"2’-9"3’-6"3’-0"2’-9"3’-0"3’-7"3’-7"2’-7"8’-4 7/8"

NOTE 1

C-13, SEE

CCR NO 1 THRU CCR NO 5

(TYPICAL)

120V RECEPTACLE

FE

B-5

C-17

HVAC-2

MC-1

C-18

CABLES

POWER

FOR

CONDUIT

3/4" EMT

EXIT

EM LT

CABLES

CONTROL

CONDUIT FOR

3/4" EMT

REGULATOR ROOM CONTROL CABLE JUNCTION BOX

E/G CONTROL CABLE JUNCTION BOXA-23E

A-23R

C-1 SUBSTATION CONTROL & MONITOR ASSEMBLY, UNIT 3

480 VAC INPUT CABINET, UNIT 4C-2

C-3 CONSTANT CURRENT REGULATOR, UNIT 5

HIGH VOLTAGE OUTPUT CABINET, UNIT 6

C-5 C-4

C-6

REMOTE MONITORING SUBSYSTEM, UNIT 12

DISTRIBUTION PANEL, UNIT 13

50 KVA TRANSFORMER, UNIT 14

SAFETY DISCONNECT SWITCH, UNIT 15

INPUT SURGE ASSEMBLY, UNIT 15A

CODEX MODEM WITH SHELF

CONTROL CABLE TRANSIENT SUPPRESSION BOX

UNINTERRUPTABLE POWER SUPPLY

KOHLER E/G MONITORING UNIT

C-13 C-12 C-11 C-10 C-9 C-8A C-8

D-1 DIESEL ENGINE GENERATOR FRAME

AUTOMATIC TRANSFER AND BYPASS SWITCH

D-3 D-2

37.5 KVA TRANSFORMER

VENTILATION POWER AND CONTROL BOX

LOAD BANK DISCONNECT SWITCH

BATTERY CHARGER

AUTOMATIC LOAD BANK

D-4 D-5 D-6 D-7 D-8 D-9 D-10

LOAD BANK CONTROL PANEL

DAY TANK

E/G REMOTE CONTROL & MONITOR BOX

METER ENCLOSURE

D-11 D-12

D-14 D-13

CURRENT TRANSFORMER CABINET

SERVICE ENTRANCE DISCONNECT SWITCH

D-16 D-15

POWER DISTRIBUTION PANELBOARD

FUEL TANK MONITOR CONTROL PANEL

LOCALIZER ROOM DISTRIBUTION PANEL DISCONECT SWITCH

EYE WASH STATIOND-18

D-17

D-19 D-20 D-23

T-2 INSIDE TEMPERATURE SENSOR (2 REQUIRED)

HVAC UNIT MASTER CONTROLLERMC-1

E-1 LOCALIZER EQUIPMENT RACK

E-2 E-3 E-4 E-5 E-6 E-7 E-8

E-10 E-9

E-12

E-15 E-14

E-16 STORAGE CABINET

WORK BENCH

MULTI-POINT GROUNDING PLATE

CONTROL CABLE JUNCTION BOX

RF JUNCTION BOX

FLOOR-MOUNTED BATTERY BOX

INNER MARKER CABINET

FAR FIELD MONITOR CABINET

FIBER OPTICS EQUIPMENT RACK

LOCALIZER ROOM DISTRIBUTION PANEL

LOCALIZER JUNCTION BOX

C-7

DISCONNECT SWITCH FOR D-16

LOCALIZER POWER PULLBOX

SURGE PROTECTION UNIT FOR PANEL E-3

NAVAIDS DISTRIBUTION PANEL BOARD

TRANSIENT SURGE SUPPRESSORS

C-17 STORAGE CABINET

C-16 WORK BENCH

C-18 DISCONNECT SWITCH FOR HVAC UNITS (TYPICAL OF 3)

FLASHER TEST STATIONC-14

1.

NOTES:

2.

6.

7.INSTALLATION PERSONNEL.

3’ COIL OF WIRE IN BOX C-10 FOR CONNECTION BY FAA

CONDUCTOR FOR TRANSIENT SUPPRESSION BOX, C-10. LEAVE

4 AWG THWN GREEN W/RED TRACER HIGH ENERGY GROUNDING

INSTALL 1" SCHEDULE 80 PVC CONDUIT THRU FLOOR WITH

PANEL, C-6 IN 15" X 12" X 4", NEMA 1 ENCLOSURE.

INSTALL POWER SURGE ARRESTER, RV-1 (GFM) FOR DISTRIBUTION

3.

CONNECTION (BY FAA INSTALLATION REPRESENTATIVES)

LEAVE 3’ COIL OF EACH CONDUCTOR IN JUNCTION BOX FOR

2-1/C 12 AWG THWN POWER AND 12 AWG GROUND IN CONDUITS.

INSTALL JUNCTION BOXES AT LOCATIONS SHOWN AND INSTALL

4.

USING 3/8" X 5" STEEL EXPANSION ANCHORS.

SECURE FLOOR-MOUNTED EQUIPMENT TO CONCRETE FLOOR

5.

CONDUITS AS THEY PENETRATE FLOOR SLAB.

MAINTAIN A MINIMUM OF 2" SEPARATION BETWEEN ADJACENT

8.

ELECTRICAL EQUIPMENT AS SHOWN AND APPROVED BY THE FAA.

PENETRATIONS OF CONCRETE SLAB FOR PROPER ENTRY TO

THE CONTRACTOR IS RESPONSIBLE FOR LOCATING CONDUIT

9.

10.

80 PVC.

CONDUITS CARRYING ONLY GROUND WIRE SHALL BE SCHEDULE

MUST BE PVC COATED GRS CONDUIT OF THE SIZE INDICATED.

EXTENDING 10’ BEYOND THE OUTSIDE WALLS OF THE BUILDING

ALL CONDUITS THAT COME IN CONTACT WITH THE EARTH AND

11.

CONCRETE. (TYPICAL FOR ALL FACILITIES)

PVC TO RIGID CONDUIT ADAPTERS MUST NOT BE ENCASED IN

12.

13.

SUITABLE FOR ELECTRICAL FIRES.

AS SHOWN. ALL FIRE EXTINGUISHERS PROVIDED SHALL BE

CONTRACTOR TO FURNISH AND MOUNT FIRE EXTINGUISHERS

14.

THIS APPLIES TO ALL WIREWAYS AT ALL FACILITIES.

GREEN COPPER CONDUCTOR PER FAA-STD-019F, PARAGRAPH 4.2.6.4.2..

SHALL BE BONDED TOGETHER WITH A MINIMUM 6 AWG INSULATED

ALL INDIVIDUAL SECTIONS OF ALL METALLIC WIREWAYS

ENSURE PROPER INSTALLATION.

BY OTHERS. COORDINATE TO

CLOUDED ITEMS TO BE INSTALLED

INSTALLATION.

PROPER CONDUIT CONNECTIONS TO THEIR ALSF EQUIPMENT

COORDINATE WITH THE CITY’S CONTRACTORS ON LOCATION AND

AND -E011. 2 SHEETS MAY BE REQUIRED.

DIAGRAM AS REQUIRED PER SHEET ORD-D-ALS09C-E010

LOCATION OF CONTRACTOR PROVIDED 11"X17" ONE LINE

AND INSTALLED BY FAA INSTALLATION PERSONNEL

THIS ITEM WILL BE FURNISHED BY GOVERNMENT *LEGEND:

GROUNDING PLATE

01’ 2’ 5’

SCALE: 1/2" = 1’-0"

1’

15.

16.

REQUIRED BY FAA-STD-019F.

CONNECTING CONDUITS SHALL BE SEALED WITH DUCT SEAL AS

WORKBENCHES, E.T.C.

OUTLETS TO BE INSTALLED TO NOT INTERFERE WITH CABINETS,

BY FAA INSTALLATION PERSONNEL

TO REQUIRED LENGTH AND CONDUCTOR WILL BE TERMINATED

OF CONDUCTOR COILED INSIDE BUILDING. CONDUIT WILL BE CUT

GROUNDING CONDUCTOR USING EXOTHERMIC WELD AND LEAVE 2’

CONDUCTOR. BOND END OF CONDUCTOR TO PERIMETER

4 AWG THWN GREEN W/RED TRACER HIGH ENERGY GROUNDING

INSTALL 1" SCHEDULE 80 PVC CONDUIT THRU FLOOR WITH

TRACER ROUTED IN 1" SCH 80 PVC.

2 GREEN WITH ORANGE #2-4/0 GREEN. CONNECT BOTH PLATES WITH

INSTALL 2" SCHEDULE 80 PVC CONDUIT CONTAINING 1-500 MCM OR

8" SQ. DUCT FOR CTRL AND GROUNDING CABLES ONLY, 12’-0" LONG

2-2" CONDUIT WITH FLASHER CONTROL CABLE

EM LT

STORAGE CABINET (ON ROLLERS)

17.

OTHER GROUND PLATE

1" SCH80 PVC TO

FED FROM UPS

(TYP. OF 2)

20A REC.

STATION, C-14

FLASHER TEST

BY CONTRACTOR)

(PROVIDED AND INSTALLED

SHUT-OFF SWITCH

REMOTE E/G EMERGENCY

PADS (TYPICAL)

MAINTANENCE

CONDUCTOR IN 1" CONDUIT

GROUNDING

2/0 AWG THWN GREEN

C-4 1-2" CONDUIT (SPARE WITH PULL CORD)

FROM HIGH VOLTAGE OUTPUT CABINET,

2-1/C #8 5KV LOOP POWER CABLES

6-2" CONDUIT-EACH WITH

PANEL

CONTROL

TO E/G

PANEL, D-20

TO DIST

10, TYPICAL)

(SEE NOTE

3" CONDUIT

OUTPUT CABINET, C-4

CABLES TO HIGH VOLTAGE

2" CONDUIT WITH CONTROL

CABLE JUNCTION BOX, E-11

2" CONDUIT TO CONTROL

CONDUCTOR. SEE NOTE 1

PERIMETER GROUNDING

1" CONDUIT TO

TO COUNTERPOISE

2" CONDUIT

GROUNDING PLATE

TO MULTI-POINT

2" CONDUIT

PANEL, C-6, SEE NOTE 10

POWER DISTRIBUTION

2" CONDUIT FROM

SCALE: 1/2" = 1’-0"

ELEVATION

SOUTH WALL OF REGULATOR ROOM

HVAC-2 CIRCUIT IN PANEL C-6

GREEN WIRE TO HVAC-1 AND

2#6 AND 1#6 INSULATED

HVAC-2 CIRCUIT IN PANEL C-6

GREEN WIRE TO HVAC-1 AND

2#6 AND 1#6 INSULATED

TYPICAL AT HVAC UNITS

UNIT C-18, NEMA 3R,

DISCONNECT SWITCH,

NOTE 2

SEE

VIA CONNECTIONS TO EG ROOM PANEL D-20.

TEMPORARILY POWER C-6 (OR ITS SUBSTITUTE)

DUCT

6" SQUARE

IN THIS SQUARE DUCT

SHALL BE INSTALLED

GROUNDING CONDUCTORS

ONLY POWER AND

GROUND PLATE

TO OTHER

1" SCH80 PVC

E D

M

IS

S

U E

D F

O R

NAVAIDS

IL

10/31/2019 1898272

ORD-D-ALS09R-C006

ENGINEERING SERVICES

ALS

RUNWAY 9R ALSF-2/27L LOCALIZER

EQUIPMENT ROOM INTERIOR ELEVATIONS

CHICAGO O’HARE INTERNATIONAL AIRPORTCHICAGO

PROJECT ENGINEER MGR: ENGINEERING

o rd -d -a ls r-c .d g n

THIS DRAWING PRODUCED ON THE AGL REGION MICROSTATION SYSTEM

ATO - TECHNICAL OPERATIONS CENTRAL SERVICE AREA

LKN

C O

N S

T R

U C

T

IO

N

2020-07-02T13:33:44-0500
RAFAEL CRAME
2020-07-09T14:02:17-0500
LUIS N DOMINGUEZ

File details come from the government source that posted it. Updated .