74_SP101_R1_AMENDMENT 010.pdf
PDF 378 KB Posted
- Solicitation number
- N6247026R0012
About this file
This document is a set of architectural and fire protection construction drawings for Building 60 Repairs at Portsmouth Naval Shipyard in Kittery, Maine, prepared by Naval Facilities Engineering Systems Command (NAVFAC) Mid-Atlantic. The drawings specify structural fire protection requirements using intumescent mastic fire-resistive coating on steel columns, beams, and other structural members to achieve 1-hour fire resistance ratings in compliance with the 2021 International Building Code (IBC) Type IIIB construction standards.
The technical specifications include detailed plans and sections for fireproofing applications at multiple locations: the fire pump fireproofing plan, northeast stair fireproofing plan, 1-hour rated floor assemblies (UL D925), 1-hour rated HSS columns (UL X771), and 1-hour rated beams. Key requirements mandate that fireproofing extend for the full length and height of rated structural members, including protection of connections to other members, with protection extending 12 inches beyond rated members on connecting nonrated members. The drawings reference additional sheets for wall and ceiling type details, firestopping of joints and penetrations, and structural framing plans. General notes specify that thickness of fireproofing will be based on manufacturer recommendations for unrestrained members, utilities must not be embedded in fireproofing, and fireproofing must not be concealed prior to inspection and acceptance by the contracting officer. The document is marked as final submission dated October 1, 2025, with Amendment 010 dated March 20, 2026.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AA
ANNEX
ANNEX
ANNEX
SP101
A3
(TYP)
1 HOUR INTUMESCENT MASTIC FIRE-RESISTIVE COATING
ON COLUMNS AND REMAINING STRUCTURAL MEMBERS
SUPPORTING THE FLOOR DECK ABOVE (SUCH AS BEAMS).
1-HOUR FIRE RESISTANCE RATED WALL (SEE LIFE SAFETY
SHEETS)
SLAB, SEE STRUCTURAL
SHEETS
STEEL BEAM, SEE
STRUCURAL SHEETS
INTUMESCENT MASTIC
FIRE-RESISTIVE COATING
STEEL DECK, SEE
STRUCTURAL SHEETS
FOR SIZE
SEE STRUCTURAL
SHEETS FOR DEPTH
STEEL COLUMN
INTUMESCENT MASTIC
FIRE-RESISTIVE COATING
STAIR
003B
CORRIDOR
M103
D3B
SP101
EXISTING WD T&G FLOOR
EXISTING STEEL BEAM,
SEE STRUCTURAL SHEETS
INTUMESCENT MASTIC
FIRE-RESISTIVE COATING
EXISTING 10" WD JOISTS
FIRE RATED
SEALANT
MINERAL WOOL
INSULATION
ELASTOMERIC
SPRAY FIRESTOP
RATED CEILING
TYPE C1
20 GA Z-CLIPS AT 24"
OC, FASTEN BEFORE
APPLICATION OF
SPRAY FIREPROOFING
1'-0"
PROVIDE FIREPROOFING
ON ADJACENT WOOD
JOISTS AND T&G FLOOR
FOR 12" BEYOND BEAM
EXISTING WD T&G
FLOOR
EXISTING STEEL
BEAM
INTUMESCENT MASTIC
FIRE-RESISTIVE
COATING
EXISTING 10" WD
JOISTS
PROVIDE
FIREPROOFING ON
ADJACENT WOOD
JOISTS AND T&G
FLOOR FOR 12"
BEYOND BEAM
RATED SHAFT WALL
TYPE 1G
A
DETAIL
B
DETAIL
CL
RATED CEILING
TYPE C1
D3A
SP101
SATISFACTORY TO DATE
APPROVED
FOR COMMANDER NAVFAC
SEAL
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SHEET
NAVFAC DRAWING NO.
DESIGNER
DRAWN BY
CHECKED BY
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 14 SEP 2023
DESIGN MANAGER
PROJECT MANAGER
FEAD/PM&E
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
P O
R T
S M
O U
T H
N A
V A
L S
H
IP
Y A
R D
K
IT
T
E R
Y M
E
UNCLASSIFIED
UNCLASSIFIED
U N
C L
A S
S
IF
IE
D
ACTIVITY
1740579
T. CARLETON
L. LYONS
S. RUCINSKI
/2
/2
:4
:0
A
M
C U s e rs \m d o n o v a n \D o c u m e n ts \2
.2
B L
D G
A
R C
H
IT
E C
T U
R A
L -V m d o n o v a n
V F
X R
.r v t
SP101
B
R
E P
A
IR
S
S T
R U
C T
U R
A L P
R O
T E
C T
IO
N
P A
R T
P L A
N A
N D
D E
T A
IL
S
RSH
JMR
CJE
K
IT
T E
R Y
M
E P
O R
T S
M O
U T
H N
A V
A L S
H
IP
Y A
R D
R O
IC
C
-M E
S P
PLAN
NORTH
1/8" = 1' - 0" 0 5' 10' 15' 30'
1 1/2" = 1' - 0" 0 6" 1' 2'3" 9"
3" = 1' - 0" 0 3" 6" 1'
GENERAL NOTES
GRAPHIC SCALE(S)
KEY PLAN
KEYNOTES
LEGEND
1. PROVIDE FIREPROOFING TO MAINTAIN INTERNATIONAL BUILDING
CODE (IBC), TYPE IIIB CONSTRUCTION.
2. STRUCTURAL COMPONENTS ARE AS DEFINED BY THE 2021 IBC.
3. MEMBERS ARE CONSIDERED UNRESTRAINED FOR PURPOSES OF
DETERMINING FIRE RESISTANT MATERIAL THICKNESS. THICKNESS
OF FIREPROOFING WILL BE BASED ON MANUFACTURER'S
RECOMMENDATIONS TO ACHIEVE THE REQUIRE RATING.
4. SEE SHEET AE001 FOR WALL AND CEILING TYPES.
5. SEE SHEET AE002 FOR FIRESTOPPING OF JOINTS AND
PENETRATIONS.
6. PIPES, WIRES, CONDUITS, DUCTS, OR OTHER UTILITIES MUST NO BE
EMBEDDED IN THE REQUIRED FIREPROOFING DEPTH.
7. FRAMING SHOWN ON THE SP SHEETS IS FOR REFERENCE ONLY AND
TO ESTABLISH GENERAL FIRE RESISTANCE RATING INTENT. REFER
TO THE STRUCTURAL FRAMING PLANS FOR THE FRAMING LAYOUT
AND FOR MEMBER SIZING.
8. WHEN A RATING IS INDICATED FOR A STRUCTURAL MEMBER, THIS
RATING MUST EXTEND FOR THE FULL LENGTH/HEIGHT OF THE
MEMBER AND MUST INCLUDE PROTECTION OF ITS CONNECTIONS TO
OTHER STRUCTURAL MEMBERS.
9. WHEN A RATING IS INDICATED FOR A STRUCTURAL MEMBER, NON-
RATED MEMBERS CONNECTING TO THE RATED MEMBERS MUST BE
PROTECTED AS REQUIRED FOR THE RATED MEMBER FOR 12 INCHES
BEYOND THE RATED MEMBER UNLESS NOTED OTHERWISE.
10. REFER TO UL LISTINGS FOR THE FULL DESIGN CRITERIA.
11. DO NOT CONCEAL FIREPROOFING PRIOR TO INSPECTION AND
ACCEPTANCE BY CONTRACTING OFFICER.
SCALE: 1/8" = 1'-0"
A1
FIRE PUMP FIREPROOFING PLAN
MATCH LINE
SCALE: 1 1/2" = 1'-0"
D1
1 HOUR RATED FLOOR ASSEMBLY UL D925
SCALE: 3" = 1'-0"
C3
1 HOUR RATED HSS COLUMNS UL X771
SCALE: 1/8" = 1'-0" (90.1 Appendix G 105) A3
NORTHEAST STAIR FIREPROOFING PLAN
SCALE: 1 1/2" = 1'-0"
D3
1 HOUR RATED BEAM
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
F
IN
A L
S U
B M
IS
S
IO
N
/0
1/
R
S H
A
M E
N D
M E
N T
/2
0/
R
S H
FIREPROOFING AT BEAMS, BRACING, AND COLUMNS SUPPORTING
DECK ABOVE. SEE FRAMING PLANS FOR LAYOUT AND REFER TO
DETAILS C3 AND D1/SP101.
FIREPROOFING AT BEAMS AT UNDERSIDE OF SECOND FLOOR DECK.
REFER TO DETAIL D3/SP101.
| Sheets |
| AE105 - SECOND FLOOR PLAN |
| AE401 - ENLARGED FIRST FLOOR TOILET ROOM AND INTERIOR ELEVATION |
| AE402 - ENLARGED SECOND FLOOR TOILET ROOM PLANS AND ELEVATIONS |
| AE441 - ENLARGED STAIR PLANS 2 |
| AE444 - STAIR DETAILS |
| AE511 - METAL PANEL DETAILS |
| AE601 - DOOR SCHEDULE AND DETAILS |
| AE640 - ROOM FINISH SCHEDULE |
| SP101 - STRUCTURAL PROTECTION PART PLAN AND DETAILS |
File details come from the government source that posted it. Updated .