183_P-701_R1_AMENDMENT 010.pdf
PDF 216 KB Posted
- Solicitation number
- N6247026R0012
About this file
This document is a Sanitary and Vent Plumbing Riser Diagram for Building 60, a technical drawing that illustrates the plumbing system design and layout. The diagram depicts the sanitary drainage, vent, and water supply piping systems throughout a multi-story facility, with detailed riser diagrams showing pipe sizes ranging from 1.5 inches to 4 inches in diameter. Key components illustrated include floor penetrations, trap primers, drain pans with air gaps, and connections to mechanical and custodial spaces across multiple floors and a mezzanine level.
The drawing indicates connections to various spaces identified as Men's, Women's, and Custodial facilities, Mechanical Rooms (M101-M110), Shop areas (110-111), Storage (109), Break Room, and Corridor spaces. Notable design features include offsets around first and second floor bridge crane rails and in-attic routing of certain lines. The document is marked as "UNCLASSIFIED" and includes general notes referencing a plumbing legend for abbreviations and detailed specifications. The drawing was last modified on March 20, 2026, and is designated as Sheet P-701 within the project documentation package.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
4" FCO
4" FCO
FD-1
WC-1
WC-2
WC-2
4" FCO
4" FCO
FD-1
4" FCO
MR-1
L-1
L-1
L-1
L-1
4" FCO
FD-1
MR-1
FCO
MR-1
L-1
L-1
3" FCO
WC-2
WC-1
WC-2
L-1
L-1
S-1
S-1
CO
U-1WC-1
2" FCO
S-1
4" VTR
SAN
SAN
WOMEN
MEN
BREAK
M101
MECH
M106
CUSTODIAL
M104 SHOP
CORRIDOR
M103
MEN
WOMEN
CUSTODIAL
4"
4"
4"
2"
FLOOR
PENETRATION (TYP)
4"
2"
4" 2"
4"
3"
4"
1 1/2"
2"
4"
2"
4"
2"
2"
4"
2"
3"
4"
CO
3"
2"
1 1/2" 2"
1 1/2"2"
2"
2"
S-3
2"
2"
2"
4"
2"
4"
2"
1 1/2"
4"
4"2"
3"
2"
3"
3"
4" FCO
FS-1
4" 2" V
4" FCO
W
W4"
4"
FD-3
4"
2" V
2" V3" VTR
3" VTR
FD-2
3" W
1 1/2" V
3" VTR
W
W 3"
4"
4"
4"
4" FCO
4"
SAN
SAN
SAN
SAN
EW
EWC
S-2
W
4"
4" 2" V
3" IW W/FUNNEL
TRAP PRIMER 1
OFFSET AROUND 1ST FLOOR
BRIDGE CRANE RAIL
OFFSET AROUND 2ND FLOOR
BRIDGE CRANE RAIL
IN ATTIC
2" CO
2" W
2" FCO
2"
2" IW W/
FUNNEL
S-1
FD-3
4"
3" VTR
2"
2" V
EWC
EW
SHOP
3"
1 1/2"
MECH
MEZZ
M110
STORAGE
3" CO SHOP
2"
2"
2"
3" W
4" CO
2" V
2" V
MULTI
PURPOSE
DRAIN PAN
AIR GAP
1 1/2" IW
MEZZ
M201
SATISFACTORY TO DATE
APPROVED
FOR COMMANDER NAVFAC
SEAL
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SHEET
NAVFAC DRAWING NO.
DESIGNER
DRAWN BY
CHECKED BY
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 14 SEP 2023
DESIGN MANAGER
PROJECT MANAGER
FEAD/PM&E
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
P O
R T
S M
O U
T H
N A
V A
L S
H
IP
Y A
R D
K
IT
T
E R
Y M
E
UNCLASSIFIED
UNCLASSIFIED
U N
C L
A S
S
IF
IE
D
ACTIVITY
1740579
T. CARLETON
L. LYONS
S. RUCINSKI
/2
/2
:2
:3
P
M
C U s e rs \s ri c h a rd s \D o c u m e n ts
\2
.2
B
L D
G
M
E C
H A
N
IC
A L
-V s w h it e G
Z D
.r v t
P-701
B
R
E P
A
IR
S
P L U
M B
IN
G
R
IS
E R
D
IA
G R
A M
MSA
RNC
SRW
K
IT
T E
R Y
M
E P
O R
T S
M O
U T
H N
A V
A L S
H
IP
Y A
R D
R O
IC
C
-M E
P -7
SCALE: NOT TO SCALE
C1
SANITARY AND VENT PLUMBING RISER DIAGRAM
GENERAL NOTES
KEYNOTES
1. SEE P-001 FOR PLUMBING LEGENDS, ABBREVIATIONS AND GENERAL
NOTES.
1 1/2" TRAP PRIMER CONNECTION. SEE PLANS FOR PIPE ROUTING TO
TRAP PRIMER ASSEMBLY.
(THIS SHEET ONLY)
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
F
IN
A L
S U
B M
IS
S
IO
N
/0
1/
R
S H
A
M E
N D
M E
N T
/2
0/
R
S H
| Sheets |
| M-703 - MECHANICAL CONTROL DIAGRAMS 3 |
| MD102 - FIRST FLOOR MECHANICAL DUCTWORK REMOVALS PLAN - EAST |
| P-101 - UNDERSLAB PLUMBING PLAN - EAST |
| P-102 - UNDERSLAB PLUMBING PLAN - WEST |
| P-103 - FIRST FLOOR PLUMBING PLAN - EAST |
| P-104 - FIRST FLOOR PLUMBING PLAN - WEST |
| P-105 - FIRST FLOOR MEZZANINE PLUMBING PLAN - EAST |
| P-106 - FIRST FLOOR MEZZANINE PLUMBING PLAN - WEST |
| P-107 - SECOND FLOOR PLUMBING PLAN |
| P-108 - SECOND FLOOR MEZZANINE PLUMBING PLAN |
| P-109 - ATTIC PLUMBING PLAN |
| P-401 - ENLARGED PLUMBING PART PLANS 1 |
| P-402 - ENLARGED PLUMBING PART PLANS 2 |
| P-403 - ENLARGED PLUMBING PART PLANS 3 |
| P-601 - PLUMBING SCHEDULES AND DETAIL |
| P-701 - PLUMBING RISER DIAGRAM |
| PD102 - FIRST FLOOR PLUMBING REMOVALS PLAN - EAST |
File details come from the government source that posted it. Updated .