About this file

This document is a mechanical engineering drawing for Building 60, depicting detailed plumbing plans for the first floor. The drawing contains four enlarged plan views showing sanitary waste and vent systems (Plans C1 and A1) and domestic water supply systems (Plans C3 and A3), all drawn at a scale of 1/4" = 1'-0". The plans identify specific rooms including office, corridor, stairs, women's and men's restrooms, custodial space, inspection room, and network areas.

The sanitary waste and vent plans illustrate waste pipe routing with various sizes ranging from 1.5 inches to 4 inches, including floor-mounted and wall-mounted configurations with multiple vent risers and cleanout locations. The domestic water supply plans show cold water (CW) and hot water (HW) distribution systems with pipe sizes from 1/2 inch to 3 inches, including a water meter connection, floor-mounted domestic water entrance on a stand, and various supply branches to fixtures. The document includes general notes referencing plumbing legends, abbreviations, clearance requirements, and notes regarding floor stancheons, quick disconnect fittings, and operational travel paths. The drawing is marked as unclassified and includes a key plan showing the relationship between the four detailed plan views and indicates this is part of a larger Building 60 mechanical documentation set dated 3/20/2026.

View the file

Other files

File Type Posted
AMENDMENT 0011 Attachments.zip ZIP file
Solicitation Amendment N6247026R00120011 SF 30.pdf PDF
Att. GG) Amendment 0011 Attachment Table of Contents.pdf PDF
222_M-703_R1_AMENDMENT 010.pdf PDF
96_AE105_R2_AMENDMENT 010.pdf PDF
183_P-701_R1_AMENDMENT 010.pdf PDF
123_AE444_R1_AMENDMENT 010.pdf PDF
Att. Y) PPI responses AMD 0010.pdf PDF
Att. FF) Amendment 0010 Attachment Table of Contents.pdf PDF
14 24 23_AMENDMENT 010.pdf PDF
120_AE441_R1_AMENDMENT 010.pdf PDF
179_P-402_R1_AMENDMENT 010.pdf PDF
171_P-103_R1_AMENDMENT 010.pdf PDF
01 11 00.00 22_AMENDMENT 010.pdf PDF
164_PD102_R1_AMENDMENT 010.pdf PDF
132_AE601_R1_AMENDMENT 010.pdf PDF
275_ET102_R1_AMENDMENT 010.pdf PDF
182_P-601_R2_AMENDMENT 010.pdf PDF
126_AE511_R1_AMENDMENT 010.pdf PDF
101_AE121_R1_AMENDMENT 010.pdf PDF
74_SP101_R1_AMENDMENT 010.pdf PDF
176_P-108_R1_AMENDMENT 010.pdf PDF
_B60_Continuation Sheet_Amendment 010_03-31-26.pdf PDF
173_P-105_R1_AMENDMENT 010.pdf PDF
119_AE440_R1_AMENDMENT 010.pdf PDF
138_AE640_R1_AMENDMENT 010.pdf PDF
174_P-106_R1_AMENDMENT 010.pdf PDF
180_P-403_R1_AMENDMENT 010.pdf PDF
172_P-104_R1_AMENDMENT 010.pdf PDF
186_MD102_R1_AMENDMENT 010.pdf PDF
169_P-101_R1_AMENDMENT 010.pdf PDF
177_P-109_R1_AMENDMENT 010.pdf PDF
114_AE401_R1_AMENDMENT 010.pdf PDF
677 attach Attic_AFPR.pdf PDF
161_Q-601_R2_AMENDMENT 010.pdf PDF
170_P-102_R1_AMENDMENT 010.pdf PDF
Solicitation Amendment N6247026R00120010 SF 30.pdf PDF
175_P-107_R1_AMENDMENT 010.pdf PDF
01 30 10.00 22_AMENDMENT 010.pdf PDF
Att. T) Price Schedule AMD 0010.pdf PDF
115_AE402_R1_AMENDMENT 010.pdf PDF
249_EP102_R1_AMENDMENT 009.pdf PDF
252_EP105_R1_AMENDMENT 009.pdf PDF
256_EP502_R1_AMENDMENT 009.pdf PDF
255_EP501_R1_AMENDMENT 009.pdf PDF
Att. EE) Amendment 0009 Attachment Table of Contents.pdf PDF
18_HM101_R1_AMENDMENT 009.pdf PDF
07 22 00_R1_AMENDMENT 009.pdf PDF
238_FX400_R1_AMENDMENT 009.pdf PDF
116_AE411_R1_AMENDMENT 009.pdf PDF
Show 40 more

Latest 50 of 157 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OFFICE

CORRIDOR

STAIR

003A

WOMEN

MEN

CUSTODIAL

p e6 n e4 e3 3.5 n.9 n.5 k.5

WC-1

WC-2

WC-2

L-1

L-1

WC-1

U-1

2" W UP & DN

4" FCO

2" W DN

4" FCO

FD-1

FD-1

WCO

1 1/2" V DN

2" V DN

(TYP 3)

1 1/2" V DN

WCO

2" W DN

2" W DN,

1 1/2" V RISE

4" FCO

2" V DN

4" FCO

3" W DN

3" W&T UP

TO FD-2

4" W DN

1 1/2" V DN

MR-1

3" W DN

S-2

L-1

L-1

CO

W

2"

2"

2" V UP

1 1/2" V RISE

(TYP 2)

1 1/2"

2"

2"

1 1/2"

2"

1 1/2" V RISE

(TYP 2)

1 1/2" V UP

2"

2"

C D

3/4"

4" FCO

4" SAN UP/ DN

3" W

OFFICE

CORRIDOR

STAIR

003A

ANNEX

1 1/2" CW

2" CW

1 1/4"

1" CW

1 1/4"

3/4"

WOMEN

MEN

CUSTODIAL

p e6 n e4 e3 3.5 n.9 n.5 k.5

1 1/2"

DROP

WHA-B

WHA-A

1 1/4"

1 1/4" CW DROP

TPA

1/2" TP DN (TYP 3)

3/4" CW DROP

3/4" HW DROP

3/4" DHWR RISE

3/4" HW UP

3/4" DHWR UP

B4 P-501

S-2

WC-1

WC-2

WC-2

L-1

L-1

WC-1

U-1

MR-1

L-1

L-1

1/2"1/2"1/2"

0.5

0.5

2"

3" TO 4" W DN

6" R DN

6" R UP

2" V UP

INSPECTION

NETWORK

(ABOVE)

A3 P-601

S-2 (BELOW)

2" W DN,

1 1/2" V RISE

j g e2 e1

EWH

BFP-1

D4 P-501 1"

IW

ODP

IW5"5"

3/4"

1" CD UP

C D

1"

A4 P-601

1 1/2" V

EWC

EW

-4" CO

3"

INSPECTION

NETWORK

1 1/2" CA DN

2 1/2" CW UP

3" CW DN

W/ BVIV

3/4" CA UP

1 1/2" CA

UP & DROP

WATER

METER

BFP-1

DOMESTIC WATER

ENTRANCE ON

FLOOR MTD STAND

D4 P-501

FLOOR

STANCHEON

3/4" CW

EMV-1

j g e2 e1

A3 P-601

EXT-P2

EWH

CA

CA PRESSURE SENSOR

EWC

A3 P-601

A4 P-601

A5 P-601

1/2"

TMV-2

3/4"

A3 P-601 3/4"

1/2"

EW

TPA

1/2" CW

1/2" TP TO IW PRIMER PORT

SATISFACTORY TO DATE

APPROVED

FOR COMMANDER NAVFAC

SEAL

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SHEET

NAVFAC DRAWING NO.

DESIGNER

DRAWN BY

CHECKED BY

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

DRAWFORM REVISION: 14 SEP 2023

DESIGN MANAGER

PROJECT MANAGER

FEAD/PM&E

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

P O

R T

S M

O U

T H

N A

V A

L S

H

IP

Y A

R D

K

IT

T

E R

Y M

E

UNCLASSIFIED

UNCLASSIFIED

U N

C L

A S

S

IF

IE

D

ACTIVITY

1740579

T. CARLETON

L. LYONS

S. RUCINSKI

/2

/2

:2

:2

P

M

C U s e rs \s ri c h a rd s \D o c u m e n ts

\2

.2

B

L D

G

M

E C

H A

N

IC

A L

-V s w h it e G

Z D

.r v t

P-401

B

R

E P

A

IR

S

E N

L A

R G

E D

P L U

M B

IN

G

P A

R T

P L A

N S

MSA

RNC

SRW

K

IT

T E

R Y

M

E P

O R

T S

M O

U T

H N

A V

A L S

H

IP

Y A

R D

R O

IC

C

-M E

P -4

SCALE: 1/4" = 1'-0" (P-104)

C1

ENLARGED FIRST FLOOR SANITARY WASTE AND VENT PART PLAN

SCALE: 1/4" = 1'-0" (P-104)

C3

ENLARGED FIRST FLOOR DOMESTIC WATER SUPPLY PART PLAN

1/4" = 1' - 0" 0 5' 10' 15'1'

GENERAL NOTES

GRAPHIC SCALE

KEY PLAN

KEYNOTES

1.

2.

SEE P-001 FOR PLUMBING LEGENDS, ABBREVIATIONS AND GENERAL

NOTES.

COORDINATE THE INSTALLATION OF PIPING AND EQUIPMENT TO

MAINTAIN MANDATORY CLEARANCE ZONES AROUND CRANE RAILS AND

BRIDGE CRANE OPERATIONAL TRAVEL PATH.

MATCH LINE

CHECK GRAPHIC SCALE BEFORE USING

PLAN

NORTH

1 PIPE 3/4" DRAIN DOWN TO SINK S-2. SECURE TO WALL.

3" INDIRECT WASTE DRAIN TRAP WITH FUNNEL OPENING FITTING. PIPE

DRAIN FROM BFP-1 AND CONDENSATE DRAINS FROM BCU-1 AND IU-2

TO AIR GAP FITTING PROVIDE TRAP WITH PRIMER PORT.

PROVIDE 1/2" CA WITH ISOLATION BALL VALVE AND QUICK CONNECT

FEMALE HOSE CONNECTION FITTING 80" AFF. COORDINATE QUICK

CONNECT FITTING SELECTION WITH CONTRACTING OFFICER.

PROVIDE 8"X8" WALL MOUNTED WATER HAMMER ARRESTOR SERVICE

ACCESS DOOR.

C1 P-401

C3 P-401

SCALE: 1/4" = 1'-0" (P-104)

A1

ENLARGED FIRST FLOOR SANITARY WASTE AND VENT PART PLAN

SCALE: 1/4" = 1'-0" (P-104)

A3

ENLARGED FIRST FLOOR DOMESTIC WATER SUPPLY PART PLAN

A1 P-401

A3 P-401

(THIS SHEET ONLY)

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

F

IN

A L

S U

B M

IS

S

IO

N

/0

1/

R

S H

A

M E

N D

M E

N T

/1

0/

R

S H

A

M E

N D

M E

N T

/2

0/

R

S H

22 22

SPLIT SYSTEM

INDOOR UNIT

Sheets
M-703 - MECHANICAL CONTROL DIAGRAMS 3
MD102 - FIRST FLOOR MECHANICAL DUCTWORK REMOVALS PLAN - EAST
P-101 - UNDERSLAB PLUMBING PLAN - EAST
P-102 - UNDERSLAB PLUMBING PLAN - WEST
P-103 - FIRST FLOOR PLUMBING PLAN - EAST
P-104 - FIRST FLOOR PLUMBING PLAN - WEST
P-105 - FIRST FLOOR MEZZANINE PLUMBING PLAN - EAST
P-106 - FIRST FLOOR MEZZANINE PLUMBING PLAN - WEST
P-107 - SECOND FLOOR PLUMBING PLAN
P-108 - SECOND FLOOR MEZZANINE PLUMBING PLAN
P-109 - ATTIC PLUMBING PLAN
P-401 - ENLARGED PLUMBING PART PLANS 1
P-402 - ENLARGED PLUMBING PART PLANS 2
P-403 - ENLARGED PLUMBING PART PLANS 3
P-601 - PLUMBING SCHEDULES AND DETAIL
P-701 - PLUMBING RISER DIAGRAM
PD102 - FIRST FLOOR PLUMBING REMOVALS PLAN - EAST

File details come from the government source that posted it. Updated .