This is an architectural drawing—specifically a Roof Part Plan (West elevation) for Building 60. The document is classified as UNCLASSIFIED and dated 3/23/2026, prepared by Oak Point Associates using Revit software (file reference 22103.25_BLDG60_ARCHITECTURAL-V23).
The drawing depicts the western roof section of the building and identifies multiple roofing components and systems requiring coordination. Key elements include existing asphalt shingle roofing with varying pitch slopes (ranging from 1"/12" to 12"/12"), existing membrane roofing, existing snow guards, existing parapets, ridges, and valleys. The plan specifies several mechanical and electrical systems requiring detailed coordination: mechanical equipment curbs, vents through roof, membrane roof systems, ballasted fall protection railing systems, lightning protection terminals and conductors, pitch pockets, and sleepers. Roof dimensions are annotated throughout, with overall western length noted as approximately 43'-11" and various sectional measurements provided. The drawing references multiple detail sheets (AE521, AE522, AE523) and mechanical/electrical specification sheets. General construction notes are cross-referenced to sheet G-004A. A keynote system with numbered references (1-7) correlates to specific construction details and coordination requirements, including notation that the fall protection railing system configuration must be coordinated with the contracting officer. The key plan indicates the location of this western roof section within the overall building footprint.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AA
C1
AE203
A1
AE204
A1
AE203
A1
AE202
C1
AE202
C1
AE221
A1
AE221
C1
AE222
abcdefgjknp e1 e2 e3 e4 e5 e6 e7
(LOWER ROOF BELOW)
EXISTING MEMBRANE
ROOFING
12" / 12"
1" / 12" 1" / 12"
1"
/ 1 2"
C1
AE223
EXISTING HISTORIC
BRICK MASONRY
PARAPET WALL
EXISTING METAL
PAN ROOFING AT
ROOF EDGE
EXISTING ASPHALT
SHINGLE ROOFING
EXISTING ASPHALT
SHINGLE ROOFING
EXISTING SNOW
GUARDS, TYP.
1"
/ 1 2"
/ 1 2"
1"
1"
/ 1 2"
12" / 12"
EXISTING SNOW
GUARDS, TYP.
3.5
2.8
2.5
2.1 n.9 k.9 k.1
2.4 n.5 k.5
1"
4" / 12"
1/2" / 12" 1/2" / 12"
1"
1" / 12"
A4
AE521
A4
AE521
D5
AE522
D5
AE522
D1
AE522
D3
AE522
B3
AE522
D5
AE522
(SIM)
43' - 11" ± 3'
1/
2"
33' - 7 1/2" ±
1'
2' - 0 1/2" ±
C1
AD203
6 6 6 6 6 6 6 6 6
EXISTING
PARAPET
VALLEY
RIDGES
RIDGE
A1
AE223
EXISTING CANOPY
BELOW
EXISTING CANOPY
BELOW
SATISFACTORY TO DATE
APPROVED
FOR COMMANDER NAVFAC
SEAL
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SHEET
NAVFAC DRAWING NO.
DESIGNER
DRAWN BY
CHECKED BY
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 14 SEP 2023
DESIGN MANAGER
PROJECT MANAGER
FEAD/PM&E
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
P O
R T
S M
O U
T H
N A
V A
L S
H
IP
Y A
R D
K
IT
T
E R
Y M
E
UNCLASSIFIED
UNCLASSIFIED
U N
C L
A S
S
IF
IE
D
ACTIVITY
1740579
T. CARLETON
L. LYONS
S. RUCINSKI
/2
/2
:0
:4
A
M
C U s e rs \c e a rl \D o c u m e n ts \2
.2
B L
D G
A
R C
H
IT
E C
T U
R A
L -V c e a rl H
C L D
R .r v t
AE121
B
R
E P
A
IR
S
R O
O F
P A
R T
P L A
N
W E
S T
RSH
JMR
MJD
K
IT
T E
R Y
M
E P
O R
T S
M O
U T
H N
A V
A L S
H
IP
Y A
R D
R O
IC
C
-M E
A E
SCALE: 1/8" = 1'-0"
B1
ROOF PART PLAN - WEST
MATCH LINE
PLAN
NORTH
1/8" = 1' - 0" 0 5' 10' 15' 30'
GRAPHIC SCALE(S)
KEY PLANGENERAL NOTES KEYNOTES
1. SEE SHEET G-004A FOR GENERAL CONSTRUCTION NOTES.
MECHANICAL EQUIPMENT CURB, SEE MECHANICAL SHEETS AND DETAIL A1/AE521.
VENT THROUGH ROOF, SEE DETAIL D1/AE521.
MEMBRANE ROOF SYSTEM, SEE DETAIL B4/AE521
REINSTALL BALLASTED FALL PROTECTION RAILING SYSTEM COORDINATE CONFIGURATION WITH CONTRACTING OFFICER.
MECHANICAL EQUIPMENT, SEE MECHANICAL SHEETS AND DETAILS A2/AE521 (PITCH POCKET) AND B1/AE522 (SLEEPER).
LIGHTNING PROTECTION TERMINAL AND CONDUCTOR, SEE DETAILS A1/AE522 AND B5/AE522 AND ELECTRICAL SHEETS.
VENT THROUGH ROOF, SEE DETAIL B1/AE521.
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
F
IN
A L
S U
B M
IS
S
IO
N
/0
1/
R
S H
A
M E
N D
M E
N T
/2
0/
R
S H
7 11
| Sheets |
| AE121 - ROOF PART PLAN - WEST |
File details come from the government source that posted it. Updated .