275_ET102_R1_AMENDMENT 010.pdf
PDF 657 KB Posted
- Solicitation number
- N6247026R0012
About this file
This document is an electrical architectural plan sheet for Building 60, specifically the First Floor Technology and Security Part Plan - West section, prepared by Oak Point and dated 3/31/2026.
The sheet provides detailed specifications for telecommunications and security infrastructure installations. Key requirements include: providing pathways for access control systems in the base bid with access control system devices, equipment, cabling, and testing as an optional component (Option 4); installing government-furnished network cabinet(s) to serve multiple outlets in designated areas such as the CNC/Gerber machine area; providing network cabins with specifications detailed on sheet ET502; installing wall-mounted telephone backboards and punchdown blocks; providing ladder cable tray and accessories; establishing duct bank entry points for existing telephone outside plant cable with termination on building protector assembly; routing conduit with minimum sealers in specified shop areas; bonding shielded cables and patch telecommunications cable to ground; and providing shielded telecommunications cabling and security cabling. Additional coordination requirements include exact location confirmation with the contracting officer for cabinets, conduits, outlets, and viewing panels; avoiding existing pits with removable pit covers post-installation; and ensuring communications cables and conduits are not routed through stairs unless directly serving stair components. Related detail references include sheets ET501, ET502, and EY501 for comprehensive telecommunications riser diagrams, security details, and elevator lobby communications systems.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AA
F
G
HI
JK
LM
N
O
P
E6
E7
POTS
REX
RFID
RFID
R E
X
BR
W
RFID
BR
WOMEN
CUSTODIAL
CORRIDOR
MEN
STAIR
003A OFFICE
ELEV MACHINE
001A
SHOP
ELEV
STAIR
002A
VEST
STORAGE
SHOP
ELECTRICAL
NETWORK
STAIR
004A
MECH
POTS11
ARCM
SC
RFID
18"W X 4"H
SATISFACTORY TO DATE
APPROVED
FOR COMMANDER NAVFAC
SEAL
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SHEET
NAVFAC DRAWING NO.
DESIGNER
DRAWN BY
CHECKED BY
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 14 SEP 2023
DESIGN MANAGER
PROJECT MANAGER
FEAD/PM&E
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
P O
R T
S M
O U
T H
N A
V A
L S
H
IP
Y A
R D
K
IT
T
E R
Y M
E
UNCLASSIFIED
UNCLASSIFIED
U N
C L
A S
S
IF
IE
D
ACTIVITY
1740579
T. CARLETON
L. LYONS
S. RUCINSKI
/3
/2
:0
:4
P
M
C U s e rs \r w ill ia m s \D o c u m e n ts \2
.2
B L D
G
E L
E C
-V
R a n d o lp h W ill ia m s .r v t
ET102
B R
E P
A
IR
S
F
IR
S T
F L O
O R
T E
C H
N O
L O
G Y
A N
D S
E C
U R
IT
Y
P A
R T
P L A
N
W E
S T
JAT
HRM
BPD
K
IT
T E
R Y
M
E P
O R
T S
M O
U T
H N
A V
A L S
H
IP
Y A
R D
R O
IC
C
-M E
E T
PLAN
NORTH
1/8" = 1' - 0" 0 5' 10' 15' 30'
GRAPHIC SCALE
KEY PLANGENERAL NOTES KEYNOTES
11. REFER TO SHEETS ET501-ET502 FOR TELECOMMUNICATIONS RISER
DIAGRAMS AND DETAILS.
2. [BASE BID]: PROVIDE PATHWAYS FOR ACCESS CONTROL SYSTEM.
[OPTION 4]: PROVIDE ACCESS CONTROL SYSTEM DEVICES,
EQUIPMENT, CABLING, AND TESTING.
3. REFER TO SHEET EY501 FOR SECURITY DETAILS.
COORDINATE EXACT LOCATION WITH THE CONTRACTING OFFICER.
ROUTE CONDUIT AND CABLE BACK TO GOVERNMENT FURNISHED WALL
MOUNTED NETWORK P CABINET. OUTLET MUST CONTAIN 1 NETWORK
P SHIELDED JACK AND CABLE.
PROVIDE NETWORK N CABINET. REFER TO DETAIL A2/ET502.
COORDINATE EXACT LOCATION TO AVOID EXISTING PIT. ENSURE PIT
COVER IS REMOVABLE AFTER CABINET INSTALLATION.
PROVIDE NETWORK P CABINET. REFER TO DETAIL A2/ET502.
COORDINATE EXACT LOCATION TO AVOID EXISTING PIT. ENSURE PIT
COVER IS REMOVABLE AFTER CABINET INSTALLATION.
PROVIDE WALL MOUNTED TELEPHONE BACKBOARD AND PUNCHDOWN
BLOCKS.
PROVIDE LADDER CABLE TRAY AND ACCESSORIES.
PROVIDE WALL MOUNTED TELEPHONE BACKBOARD AND BUILDING
PROTECTOR ASSEMBLY.
DUCT BANK ENTRY POINT FOR EXISTING TELEPHONE OUTSIDE PLANT
CABLE. ROUTE CABLES THROUGH THE EXISTING PIT AND TERMINATE
ON BUILDING PROTECTOR ASSEMBLY.
MATCH LINE
SCALE: 1/8" = 1'-0"
B1
FIRST FLOOR TECHNOLOGY AND SECURITY PART PLAN - WEST
8 INSTALL GOVERNMENT FURNISHED WALL MOUNTED NETWORK P
CABINET. CABINET SERVES FOUR OUTLETS WITHIN THE CNC/GERBER
MACHINE AREA. COORDINATE EXACT LOCATION WITH THE CONTRACTING
OFFICER AND ADJACENT EQUIPMENT.
[BASE BID]: PROVIDE JUNCTION BOX AT EXISTING COMMUNICATIONS
ENTRANCE. PROVIDE IN SIZE TO ACCOMMODATE SPLICE OF EXISTING
NETWORK N AND NETWORK P OUTSIDE PLANT CABLES. COORDINATE
EXACT LOCATION IN THE FIELD. PROVIDE LABEL INDICATING "NETWORK N
AND NETWORK P OUTSIDE PLANT CABLE ENTRANCE". REFER TO SHEET
ET501.
FOR ELEVATOR LOBBY 2 WAY COMMUNICATIONS SYSTEM. REFER TO
DETAIL A3/ET501.
PROVIDE SHIELDED TELECOMMUNICATIONS CABLING AND [OPTION 4]:
SECURITY CABLING ON THIS LEVEL.
FOR PRINTER. COORDINATE EXACT LOCATION WITH THE CONTRACTING
OFFICER.
COMMUNICATIONS CABLES AND CONDUITS MUST NOT BE ROUTED
THROUGH THE STAIR UNLESS THEY ARE DIRECTLY RELATED TO AN ITEM
SERVING THE STAIR.
ROUTE CONDUIT A MINIMUM OF 15 FEET AWAY FROM THE HEAT
SEALERS IN SHOP 111.
[BASE BID]: DUCT BANK ENTRY POINT FOR 6-STRAND MULTIMODE
NETWORK P FIBER OPTIC CABLE FROM BUILDING 59. EXTEND CABLE TO
GOVERNMENT PROVIDED NETWORK P CABINET IN SHOP 110. [OPTION
11]: DUCT BANK ENTRY POINT FOR (2) 36 STRAND CABLES FOR
NETWORKS N AND P.
BOND SHIELDED CABLES, PATCH PANELS, RACKS, AND CABLE TRAY TO
TELECOMMUNICATIONS GROUNDING SYSTEM. REFER TO SHEET EP102
FOR PRIMARY GROUNDING BUSBAR.
COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH THE
SLIDING DOOR.
PROVIDE VIEWING PANEL IN THE ELEVATOR MACHINE ROOM.
COORDINATE EXACT LOCATION WITH THE ELEVATOR INSTALLER AND
CONTRACTING OFFICER. REFER TO THE ELEVATOR SPECIFICATION FOR
ADDITIONAL INFORMATION.
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
F
IN
A L
S U
B M
IS
S
IO
N
/0
1/
R
S H
A
M E
N D
M E
N T
/2
0/
R
S H
| Sheets |
| ET102 - FIRST FLOOR TECHNOLOGY AND SECURITY PART PLAN - WEST |
File details come from the government source that posted it. Updated .