About this file

This is an architectural drawing sheet for hazardous materials abatement work at Portsmouth Naval Shipyard in Kittery, Maine. The document is a First Floor Hazardous Materials Part Plan - East (Sheet HM101) for Building 60 Repairs, prepared by Naval Facilities Engineering Systems Command (NAVFAC) Mid-Atlantic. The drawing is dated with a final submission of October 1, 2025, and an amendment dated March 16, 2026.

The sheet identifies multiple hazardous materials requiring abatement and removal, including asbestos-containing pipe insulation, asbestos-containing mastics at wood strip flooring removals and penetrations, and heavy metals-containing paint on concrete, brick, and steel surfaces. Specific work tasks include managing disturbances to grey and red floor paint on concrete and white paint on brick; abating and removing loose and flaking heavy metals-containing coatings on steel buttresses; removing asbestos-containing pipe insulation and heavy metals-containing paint debris from floor drains; abating black seam sealant at vertical joints between annex and brick; and abating grey sealant at bolt holes and patches on exterior wall surfaces. The drawing references additional sheets (HM001, HM603-HM604) for general notes, hazardous materials survey, and ACM and sampling schedules. The project number is 1740579, with design management by T. Carleton, drawn by L. Lyons, and checked by S. Rucinski.

View the file

Other files

File Type Posted
_B60_Continuation Sheet_Amendment 010_03-31-26.pdf PDF
74_SP101_R1_AMENDMENT 010.pdf PDF
96_AE105_R2_AMENDMENT 010.pdf PDF
114_AE401_R1_AMENDMENT 010.pdf PDF
120_AE441_R1_AMENDMENT 010.pdf PDF
178_P-401_R2_AMENDMENT 010.pdf PDF
179_P-402_R1_AMENDMENT 010.pdf PDF
01 91 19_R1_AMENDMENT 009.pdf PDF
116_AE411_R1_AMENDMENT 009.pdf PDF
238_FX400_R1_AMENDMENT 009.pdf PDF
256_EP502_R1_AMENDMENT 009.pdf PDF
260_EP601_R1_AMENDMENT 009.pdf PDF
Solicitation Amendment N6247026R00120008 SF 30.pdf PDF
Att. S) FFE Final Package-R1_AMENDMENT 008.pdf PDF
_ATTAC1.PDF PDF
02 82 00.00 22_R1_AMENDMENT 008.pdf PDF
31_CS101_R1_AMENDMENT 008.pdf PDF
47_SD102_R1_AMENDMENT 008.pdf PDF
65_SF105_R1_AMENDMENT 008.pdf PDF
68_SF502_R1_AMENDMENT 008.pdf PDF
152_G-004B_R1_AMENDMENT 008.pdf PDF
182_P-601_R1_AMENDMENT 008.pdf PDF
190_MD106_R1_AMENDMENT 008.pdf PDF
192_MD108_R1_AMENDMENT 008.pdf PDF
N6247026R00120007 SF 30.pdf PDF
Att. Y) PPI responses AMD 0007.pdf PDF
Solicitation Amendment N6247026R00120006 SF 30.pdf PDF
Solicitation Amendment N6247026R00120005 SF 30.pdf PDF
Solicitation Amendment N6247026R00120004 SF 30.pdf PDF
Att. A) Construction and Design Experience Project Data Sheet.doc.docx DOCX document
Att. E) Small Business Participation Commitment Document (SBPCD) AMD 0004.docx DOCX document
Att. D) Historical Small Business Utilization AMD 0004.docx DOCX document
Att. T) Price Schedule AMD 0004.pdf PDF
Att. BB) B60 AMD 004 Specifications 012726.pdf PDF
Att. X) DBIDS ACCESS REQUEST FORM.docx DOCX document
Amendment N6247026R00120003.pdf PDF
Att. V) SITE VISIT INFORMATION.pdf PDF
Solicitation Amendment N6247026R00120002.pdf PDF
Att. T) Price_schedule AMD 0002.pdf PDF
Solicitation Amendment N6247026R00120001.pdf PDF
Att. G) - PIEE Vendor Access Instructions.pdf PDF
Att. M) Drawings Volume 2a.pdf PDF
Att. S) FFE Package.pdf PDF
Att. U) Submittal Register.xlsx XLSX spreadsheet
Solicitation - N6247026R0012.pdf PDF
Att. B) - Pre-Proposal Inquiry Log Template.xlsx XLSX spreadsheet
Att. C) - Past Performance Questionnaire.docx DOCX document
Att. N) Drawings Volume 2b.pdf PDF
Att. O) 01 30 00 App A Red Zone 102623.pdf PDF
Att. T) Price_schedule.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C2

HM106

AA

SHOP

SHOP

SHOP

1. SEE HM001 FOR GENERAL SHEET NOTES, HAZARDOUS MATERIALS NOTES,

HAZARDOUS MATERIALS SURVEY, AND HAZARDOUS MATERIALS WORK PLAN.

2. SEE HM603-HM604 FOR SUMMARY OF ACM AND SAMPLING SCHEDULES.

3. ABATE AND REMOVE ASBESTOS CONTAINING MASTICS AT WOOD STRIP

FLOORING REMOVALS/PENETRATIONS.

SATISFACTORY TO DATE

APPROVED

FOR COMMANDER NAVFAC

SEAL

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SHEET

NAVFAC DRAWING NO.

DESIGNER

DRAWN BY

CHECKED BY

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

DRAWFORM REVISION: 14 SEP 2023

DESIGN MANAGER

PROJECT MANAGER

FEAD/PM&E

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

P O

R T

S M

O U

T H

N A

V A

L S

H

IP

Y A

R D

K

IT

T

E R

Y M

E

UNCLASSIFIED

UNCLASSIFIED

U N

C L

A S

S

IF

IE

D

ACTIVITY

1740579

T. CARLETON

L. LYONS

S. RUCINSKI

/1

/2

:5

:3

A

M

C U s e rs \m d o n o v a n \D o c u m e n ts \2

.2

B L

D G

A

R C

H

IT

E C

T U

R A

L -V m d o n o v a n

V F

X R

.r v t

HM101

B

R

E P

A

IR

S

F

IR

S T

F L O

O R

H A

Z A

R D

O U

S M

A T

E R

IA

L S

P A

R T

P L A

N

E A

S T

RSH

JMR

MJD

K

IT

T E

R Y

M

E P

O R

T S

M O

U T

H N

A V

A L S

H

IP

Y A

R D

R O

IC

C

-M E

H M

GENERAL NOTES

GRAPHIC SCALE(S)

HAZARDOUS MATERIALS

KEYNOTES

SCALE: 1/8" = 1'-0"

A1

FIRST FLOOR HAZARDOUS MATERIALS PART PLAN - EAST

PLAN

NORTH

1/8" = 1' - 0" 0 5' 10' 15' 30'

KEY PLAN

ABATE AND REMOVE ASBESTOS CONTAINING PIPE INSULATION

MANAGE DISTURBANCES TO HEAVY METALS CONTAINING GREY/RED

FLOOR PAINT ON CONCRETE AND WHITE PAINT ON BRICK.

OPTION 7: ABATE AND REMOVE (BRUSH/SCRAPE) LOOSE AND FLANKING

HEAVY METALS/ASBESTOS CONTAINING SILVER COATING ON STEEL

BUTREESSES.

ABATE AND REMOVE ASBESTOS CONTAINING PIPE INSULATION AND HEAVY

METALS CONTAINING PAINT DEBRIS SETTLED WITHIN FLOOR DRAIN TO BE

REMOVED. COORDINATE WITH PLUMBING SHEETS.

ABATE AND REMOVE (BRUSH/SCRAPE) LOOSE AND FLAKING HEAVY METALS

CONTAINING GREY COATING ON STEEL BUTTRESSES AS REQUIRED AT

INSTALLATION OF EXTERIOR METAL PANEL WALL SYSTEM (MINIMUM OF 1'

FROM EXISTING FACE OF METAL SIDING). COORDINATE WITH

ARCHITECTURAL SHEETS.

ABATE AND REMOVE BLACK SEAM SEALANT AT VERTICAL JOINT BETWEEN

ANNEX AND BRICK.

ABATE AND REMOVE GREY SEALANT AT BOLT HOLES AND PATCHES ON

EXTERIOR WALL SURFACES.

(THIS SHEET ONLY)

MATCH LINE

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

F

IN

A L

S U

B M

IS

S

IO

N

/0

1/

R

S H

A

M E

N D

M E

N T

/1

6/

R

S H

Sheets
AD104 - SECOND FLOOR REMOVALS PLAN
AD105 - SECOND FLOOR MEZZANINE REMOVALS PLAN
AE104 - FIRST FLOOR MEZZANINE PART PLAN - WEST
AE105 - SECOND FLOOR PLAN
AE411 - ENLARGED ELEVATOR PLANS AND SECTIONS
AE441 - ENLARGED STAIR PLANS 2
AE444 - STAIR DETAILS
AE511 - METAL PANEL DETAILS
AE530 - EXPANSION JOINT DETAILS 1
AE531 - EXPANSION JOINT DETAILS 2
AE601 - DOOR SCHEDULE AND DETAILS
AE640 - ROOM FINISH SCHEDULE
HM101 - FIRST FLOOR HAZARDOUS MATERIALS PART PLAN - EAST
SP101 - STRUCTURAL PROTECTION PART PLAN AND DETAILS

File details come from the government source that posted it. Updated .