Summary of Stair Details Architectural Drawing

This is an architectural drawing document containing detailed construction specifications and design details for stairways at Building 60 of Portsmouth Naval Shipyard in Kittery, Maine. The drawing was prepared by the Naval Facilities Engineering Systems Command (NAVFAC) and is classified as Unclassified. The project number is 1740579, with the final submission dated October 1, 2025, and Amendment 010 dated March 20, 2026.

The drawing provides comprehensive stair construction details including typical tread specifications (11-inch depth with abrasive cast metal safety nosing), handrail configurations (1-1/2 inch diameter metal handrails with painted finish), guardrail systems (1-1/2 inch by 1-1/2 inch metal guardrails with 1/2 inch by 1/2 inch balusters at 4-inch on-center spacing), and landing details. Key structural components specified include concrete-filled metal pan stairs, steel channel stringers, steel landing supports, and sanitary coves. The drawing includes multiple scaled detail views (ranging from 6 inches equals 1 foot to 1 1/2 inches equals 1 foot), with all metal components to be painted and all welds to be ground smooth. Additional specifications call for metal wall brackets with anchor bolts, floor anchors, and coordination with the stair manufacturer for landing support installation.

View the file

Other files

File Type Posted
AMENDMENT 0011 Attachments.zip ZIP file
Solicitation Amendment N6247026R00120011 SF 30.pdf PDF
Att. GG) Amendment 0011 Attachment Table of Contents.pdf PDF
222_M-703_R1_AMENDMENT 010.pdf PDF
96_AE105_R2_AMENDMENT 010.pdf PDF
183_P-701_R1_AMENDMENT 010.pdf PDF
Att. Y) PPI responses AMD 0010.pdf PDF
Att. FF) Amendment 0010 Attachment Table of Contents.pdf PDF
14 24 23_AMENDMENT 010.pdf PDF
120_AE441_R1_AMENDMENT 010.pdf PDF
179_P-402_R1_AMENDMENT 010.pdf PDF
171_P-103_R1_AMENDMENT 010.pdf PDF
01 11 00.00 22_AMENDMENT 010.pdf PDF
164_PD102_R1_AMENDMENT 010.pdf PDF
132_AE601_R1_AMENDMENT 010.pdf PDF
275_ET102_R1_AMENDMENT 010.pdf PDF
182_P-601_R2_AMENDMENT 010.pdf PDF
126_AE511_R1_AMENDMENT 010.pdf PDF
101_AE121_R1_AMENDMENT 010.pdf PDF
74_SP101_R1_AMENDMENT 010.pdf PDF
176_P-108_R1_AMENDMENT 010.pdf PDF
178_P-401_R2_AMENDMENT 010.pdf PDF
_B60_Continuation Sheet_Amendment 010_03-31-26.pdf PDF
173_P-105_R1_AMENDMENT 010.pdf PDF
119_AE440_R1_AMENDMENT 010.pdf PDF
138_AE640_R1_AMENDMENT 010.pdf PDF
174_P-106_R1_AMENDMENT 010.pdf PDF
180_P-403_R1_AMENDMENT 010.pdf PDF
172_P-104_R1_AMENDMENT 010.pdf PDF
186_MD102_R1_AMENDMENT 010.pdf PDF
169_P-101_R1_AMENDMENT 010.pdf PDF
177_P-109_R1_AMENDMENT 010.pdf PDF
114_AE401_R1_AMENDMENT 010.pdf PDF
677 attach Attic_AFPR.pdf PDF
161_Q-601_R2_AMENDMENT 010.pdf PDF
170_P-102_R1_AMENDMENT 010.pdf PDF
Solicitation Amendment N6247026R00120010 SF 30.pdf PDF
175_P-107_R1_AMENDMENT 010.pdf PDF
01 30 10.00 22_AMENDMENT 010.pdf PDF
Att. T) Price Schedule AMD 0010.pdf PDF
115_AE402_R1_AMENDMENT 010.pdf PDF
249_EP102_R1_AMENDMENT 009.pdf PDF
252_EP105_R1_AMENDMENT 009.pdf PDF
256_EP502_R1_AMENDMENT 009.pdf PDF
255_EP501_R1_AMENDMENT 009.pdf PDF
Att. EE) Amendment 0009 Attachment Table of Contents.pdf PDF
18_HM101_R1_AMENDMENT 009.pdf PDF
07 22 00_R1_AMENDMENT 009.pdf PDF
238_FX400_R1_AMENDMENT 009.pdf PDF
116_AE411_R1_AMENDMENT 009.pdf PDF
Show 40 more

Latest 50 of 157 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SANITARY COVE (TYP)

CONC FILLED METAL PAN STAIR (TYP)

1/2"x1/2" METAL BALUSTER AT

4" OC, PNT (TYP)

1-1/2" x 1-1/2" METAL GUARDRAIL, PNT

ABRASIVE CAST METAL SAFETY

NOSING (TYP)

FLOORING (SEE ROOM FINISH

SCHEDULE)

2' -1

0"

3' -6

B4

AE444

C L

STL CHANNEL LANDING SUPPORT

STL CHANNEL STRINGER

1-1/2" DIA MTL HANDRAIL, PNT -

RETURN TO GUARDRAIL POST

2 1/4" (MIN)

1 1/2"

2' -1

0"

3' -6

2 1/4"

4" (MAX)(TYP)

4" (M

A X

C L

STL BEAM, PNT

1-1/2" x 1-1/2" METAL GUARDRAIL

(PNT)

1-1/2" DIA MTL HANDRAIL (PNT) -

RETURN TO GUARDRAIL POST

1/2" x 1/2" METAL

BALUSTER AT 4" OC,

PNT (TYP)

CONC SLAB - SEE STRUCTURAL SHEETS

5'-0 3/4" 2 1/4"

1" (TYP)

TREAD

11"

RAIL SUPPORT AT 4'-0" OC

(MAX), PNT (TYP)

1 1/2" DIA MTL HANDRAIL,

PNT

SANITARY COVE

STEEL STRINGER PNT

CONC FILLED MTL PAN STAIR

(TYP)

2' -1

0"

11"

ABRASIVE CAST METAL

SAFETY NOSING (TYP)

FLOOR ANCHOR

RETURN TO 1/2" FROM WALL

C5

AE444

FLOORING (SEE ROOM FINISH

SCHEDULE)

AE444

A1

(TYP)

1-1/2" x 1-1/2" METAL

GUARDRAIL, PNT

1/2"x1/2" METAL BALUSTER

AT 4" OC, PNT (TYP)

FLOORING (SEE ROOM FINISH

SCHEDULE)

2' -1

0"

11"

1' -0

RETURN HANDRAIL TO

GUARDRAIL, WELD AND GRIND

SMOOTH (TYP)

B4

AE444

3'

6"

1-1/2" DIA MTL

HANDRAIL, PNT

COVER PLATE-GRIND WELDS

SMOOTH, PNT

CHANNEL BEHIND POST

HSS 1 1/2" x 1 1/2"

GUARDRAIL TURNED

DOWN

2' -1

0"

3' -6

VARIES

1 1/2"

2 1/4" (MIN)

A4

AE444

C L

ANCHOR BOLT, PNT (TYP)

MTL WALL BRACKET, PNT

1-1/2" DIA MTL HANDRAIL, PNT

ANCHOR BOLT, PNT (TYP)

MTL WALL BRACKET, PNT

SECTION

TYPICAL

ELEVATION

1-1/2" MIN

STL STRINGER

GRIND ALL WELDS SMOOTH, PNT

1-1/2" x 1-1/2" GUARDRAIL (ABOVE)

1 1/2"2 1/4"

1 1/2"

1-1/2" DIA MTL HANDRAIL, PNT

VARIES

1 1/2" DIA MTL HANDRAIL, PNT

CLOSURE PLATES

BETWEEN CHANNELS

ABRASIVE CAST METAL

SAFETY NOSING (TYP)

SANITARY COVE (TYP)

CONC FILLED MTL PAN STAIR

(TYP)

1/2"x1/2" METAL BALUSTER

AT 4" OC, PNT (TYP)

BAR BRACKETS AT EACH

1-1/2" POST

SEE FLOOR PLAN FOR

WALL TYPE

2 1/2" LIGHTWEIGHT CONC

FILLED MTL DECK LANDING

STEEL LANDING SUPPORTS

BY STAIR MANUFACTURER

A5

AE444

STL ANGLE

CLOSURE, PNT

1/2" x 1/2" MTL BALUSTER, PNT

1 1/2" X 1-1/2" MTL GUARDRAIL

POST, PNT

STL CHANNEL, PNT

CONC FILLED MTL PAN STAIR

TREAD

WELD AND GRIND SMOOTH (TYP)

3/8" DIA BAR AT EACH POST

1-1/2" x 1-1/2" MTL GUARDRAIL POST, PNT

1-1/2" DIA MTL HANDRAIL, PNT

3' -6

2' -1

0"

1-1/2" x 1-1/2" MTL GUARDRAIL, PNT

STL ANGLE CLOSURE, PNT

1-1/2" x 1-1/2" MTL GUARDRAIL, PNT

2 1/4" (MIN)

1 1/2"

1-1/2" MIN 11

GYP BD WALL,

PNT

1-1/2" DIA MTL

HANDRAIL, PNT

RETURN TO 1/2"

FROM WALL

2' -1

0"

CONC FILLED

METAL PAN STAIR

LANDING

1' - 0"

C5

AE444

C L

NOTE: ABRASIVE CAST METAL SAFETY

NOSING AT EACH TREAD AND LANDING (TYP)

METAL PAN RISER

CAST IN PLACE ABRASIVE

CAST METAL SAFETY NOSING

WITH INTEGRAL ANCHORS

(FULL LENGTH OF STEP)

CONCRETE FILLED METAL

PAN STAIR TREAD

METAL TREAD NOSING

4"

2"

ALIGN

C O

O R

D

IN

A T

E W

IT

H

M

A N

U F

A C

T U

R E

R

SATISFACTORY TO DATE

APPROVED

FOR COMMANDER NAVFAC

SEAL

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SHEET

NAVFAC DRAWING NO.

DESIGNER

DRAWN BY

CHECKED BY

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

DRAWFORM REVISION: 14 SEP 2023

DESIGN MANAGER

PROJECT MANAGER

FEAD/PM&E

FIRE PROTECTION

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

P O

R T

S M

O U

T H

N A

V A

L S

H

IP

Y A

R D

K

IT

T

E R

Y M

E

UNCLASSIFIED

UNCLASSIFIED

U N

C L

A S

S

IF

IE

D

ACTIVITY

1740579

T. CARLETON

L. LYONS

S. RUCINSKI

/2

/2

:3

:5

A

M

C U s e rs \m d o n o v a n \D o c u m e n ts \2

.2

B L

D G

A

R C

H

IT

E C

T U

R A

L -V m d o n o v a n

V F

X R

.r v t

AE444

B

R

E P

A

IR

S

S T

A

IR

D E

T A

IL

S

RSH

JMR

CJE

K

IT

T E

R Y

M

E P

O R

T S

M O

U T

H N

A V

A L S

H

IP

Y A

R D

R O

IC

C

-M E

A E

SCALE: 1" = 1'-0" (AE442)

D3

STAIR TOP FLOOR

LEVEL LANDING DETAIL (TYP)

SCALE: 1" = 1'-0" (AE440)

C4

STAIR TOP LANDING DETAIL (TYP)

SCALE: 1" = 1'-0" (AE442)

A3

STAIR RUN DETAIL (TYP)

SCALE: 1" = 1'-0" (AE442)

B3

STAIR BOTTOM LANDING (TYP)

SCALE: 1" = 1'-0" (AE444)

A5

STAIR RAILING ELEVATION (TYP)

SCALE: 1" = 1'-0" (AE444)

C5

STAIR RAILING DETAIL (TYP)

SCALE: 1 1/2" = 1'-0" (AE444)

A4

STAIR DETAIL (TYP)

SCALE: 1" = 1'-0" (AE442)

C2

STAIR LANDING DETAIL (TYP)

SCALE: 1 1/2" = 1'-0" (AE444)

B4

STAIR LANDING FLOOR LEVEL

EDGE DETAIL (TYP)

SCALE: 1" = 1'-0" (AE442)

A2

STAIR HANDRAIL DETAIL (TYP)

SCALE: 6" = 1'-0" (AE444)

A1

TYP TREAD DETAIL

6" = 1' - 0" 0 4" 6"2"1"

1" = 1' - 0" 0 6" 1' 3'2'

1 1/2" = 1' - 0" 0 6" 1' 2'3" 9"

GRAPHIC SCALE(S)

C L

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

F

IN

A L

S U

B M

IS

S

IO

N

/0

1/

R

S H

A

M E

N D

M E

N T

/2

0/

R

S H

Sheets
AE105 - SECOND FLOOR PLAN
AE401 - ENLARGED FIRST FLOOR TOILET ROOM AND INTERIOR ELEVATION
AE402 - ENLARGED SECOND FLOOR TOILET ROOM PLANS AND ELEVATIONS
AE441 - ENLARGED STAIR PLANS 2
AE444 - STAIR DETAILS
AE511 - METAL PANEL DETAILS
AE601 - DOOR SCHEDULE AND DETAILS
AE640 - ROOM FINISH SCHEDULE
SP101 - STRUCTURAL PROTECTION PART PLAN AND DETAILS