170_P-102_R1_AMENDMENT 010.pdf
PDF 402 KB Posted
- Solicitation number
- N6247026R0012
About this file
This document is an Underslab Plumbing Plan for Building 60, Sheet P-102 (West section), prepared at a scale of 1/8" = 1'-0" as of March 20, 2026. The plan depicts mechanical and plumbing infrastructure including sanitary piping, water lines, vent pipes, compressed air piping, and elevator systems throughout the building's subslab area. Key piping elements include 4-inch sanitary lines, 2-inch and 3-inch water and waste lines, 1.5-inch and 2-inch vent pipes, and 6-inch radon vent pipes with open-end elbows into crushed stone fill. The plan coordinates with multiple referenced sheets including P-001 (plumbing legends), CX101 and CS (civil sheets for underground infrastructure), and SB101 (structural infill details).
Critical coordination requirements include maintaining clearance zones around existing crane rails and bridge crane operational paths, offsetting piping through walls around existing structural piers, and integrating with existing compressed air piping from Building 60 to Building 292 (which is to be cut, capped, and abandoned in place). The plan specifies floor saw cut infills, existing floor trenches to be filled and patched, and pitch specifications for certain lines at 1/8-inch per foot. This is a technical construction document prepared in Revit and intended for contractors and construction management teams working on building renovation or modernization activities.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHOP
SHOP
VEST
STAIR
003A
ANNEX
STORAGE
MECH
ELECTRICAL
AA
CORRIDOR
ANNEX
4" UP TO FCO
4" UP
TO FCO
4" UP
TO FCO
MEN
ELEV
STAIR
002A
(E) CO
EXISTING
SANITARY
MANHOLE
6 EXISTING 4" S
(E) 4" S
4" UP
TO FCO
4"
S A
N
SAN SAN
2 5
4" W UP 6" R OE 1
6" R UP
C A
1 1/2"3
3" CW UP
3"
6" R OE 1
6" R UP
6" R OE 1
6" R UP
SAN
3" S UP
2" PW UP
(E) 3/4" CA
CAPPED
2" W UP
(E) CO
4" UP
TO FCO
2" W UP
2" V UP
1 1/2" V UP
4" UP TO FCO
2" V UP (TYP 3)
1 1/2"
V UP
2" W UP
2" W UP
WOMEN
INSPECTION
NETWORK
STAIR
004A
4" S UP (TYP 3)
4" UP TO FCO
3" W&T
1 1/2" V UP
4" W UP
2" S UP
4" S UP
4" UP
TO FCO
3" W&T
4" ABANDONED
VENT CAPPED
2" W UP
CORRIDOR
CORRIDOR
SHOP
4" m l i h e7 p e6 n k j g.1 g f.1 f
M3
5.6
4.2 e4 e3
3.5
2.8 n.9 n.5 k.9 k.5
2.5
2.4
2.1 e2 e1 k.1 e d c b a i.1
ELEV
MACHINE
001A4" W&T UP
TO FS-1
2" V UP
1/2" TP
UP (TYP 3)
3" W UP
SP
4"
SAN
S A
N
2 4" 24"
4"
S A
N
1 1/2" CA UP
24" T
P
1/2"
3" W&T
1/2"
TP
T P
1/2"
4" W&T
4" 1/2" TP UP
S A
N
4"
INV EL: 6.55'
2" W
4" UP
TO FCO
1/2"
T
P 2" V UP
SATISFACTORY TO DATE
APPROVED
FOR COMMANDER NAVFAC
SEAL
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SHEET
NAVFAC DRAWING NO.
DESIGNER
DRAWN BY
CHECKED BY
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 14 SEP 2023
DESIGN MANAGER
PROJECT MANAGER
FEAD/PM&E
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
P O
R T
S M
O U
T H
N A
V A
L S
H
IP
Y A
R D
K
IT
T
E R
Y M
E
UNCLASSIFIED
UNCLASSIFIED
U N
C L
A S
S
IF
IE
D
ACTIVITY
1740579
T. CARLETON
L. LYONS
S. RUCINSKI
/2
/2
:2
:1
P
M
C U s e rs \s ri c h a rd s \D o c u m e n ts
\2
.2
B
L D
G
M
E C
H A
N
IC
A L
-V s w h it e G
Z D
.r v t
P-102
B
R
E P
A
IR
S
U N
D E
R S
L A
B P
L U
M B
IN
G
P L A
N
W E
S T
MSA
RNC
SRW
K
IT
T E
R Y
M
E P
O R
T S
M O
U T
H N
A V
A L S
H
IP
Y A
R D
R O
IC
C
-M E
P -1
SCALE: 1/8" = 1'-0"
B1
UNDERSLAB PLUMBING PLAN - WEST
GENERAL NOTES KEYNOTES
1/8" = 1' - 0" 0 5' 10' 15' 30'
GRAPHIC SCALE
KEY PLAN
CHECK GRAPHIC SCALE BEFORE USING
MATCH LINE
PLAN
NORTH
1.
2.
SEE P-001 FOR PLUMBING LEGENDS, ABBREVIATIONS AND GENERAL NOTES.
COORDINATE THE INSTALLATION OF PIPING AND EQUIPMENT TO MAINTAIN MANDATORY CLEARANCE ZONES AROUND CRANE RAILS AND BRIDGE CRANE
OPERATIONAL TRAVEL PATH.
(THIS SHEET ONLY)
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
F
IN
A L
S U
B M
IS
S
IO
N
/0
1/
R
S H
A
M E
N D
M E
N T
/2
0/
R
S H
PROVIDE 6" RADON VENT PIPE WITH OPEN END (OE) PIPE ELBOW INTO CRUSHED STONE LAYER OF FILLED FLOOR TRENCH.
PITCH PIPE AT 1/8" PER FOOT.
SEE CIVIL SHEET CX101 FOR CONTINUATION OF EXISTING UNDER GROUND COMPRESSED AIR PIPING AND SHEET CS101 FOR REPLACEMENT UNDERGROUND
DOMESTIC WATER PIPING.
EXISTING 3/4" COMPRESSED AIR FROM BUILDING 60 TO BUILDING 292, CUT, CAPPED, AND ABANDONED IN PLACE.
EXISTING FLOOR TRENCH TO BE FILLED AND SLAB PATCHED. SEE SB101 FOR INFILL DETAILS.
SEE CIVIL SHEET CX101 FOR CONTINUATION OF EXISTING SANITARY PIPING.
SEE SHEET P-101 FOR CNTINUATION.
COORDINATE PIPING THROUGH WALL WITH EXISTING STRUCTURAL PIERS. PROVIDE OFFSET AND FITTINGS AS REQUIRED.
FLOOR SAW CUT INFILL. SEE STRUCTURAL SHEET SB101 FOR INFILL DETAILS.
| Sheets |
| M-703 - MECHANICAL CONTROL DIAGRAMS 3 |
| MD102 - FIRST FLOOR MECHANICAL DUCTWORK REMOVALS PLAN - EAST |
| P-101 - UNDERSLAB PLUMBING PLAN - EAST |
| P-102 - UNDERSLAB PLUMBING PLAN - WEST |
| P-103 - FIRST FLOOR PLUMBING PLAN - EAST |
| P-104 - FIRST FLOOR PLUMBING PLAN - WEST |
| P-105 - FIRST FLOOR MEZZANINE PLUMBING PLAN - EAST |
| P-106 - FIRST FLOOR MEZZANINE PLUMBING PLAN - WEST |
| P-107 - SECOND FLOOR PLUMBING PLAN |
| P-108 - SECOND FLOOR MEZZANINE PLUMBING PLAN |
| P-109 - ATTIC PLUMBING PLAN |
| P-401 - ENLARGED PLUMBING PART PLANS 1 |
| P-402 - ENLARGED PLUMBING PART PLANS 2 |
| P-403 - ENLARGED PLUMBING PART PLANS 3 |
| P-601 - PLUMBING SCHEDULES AND DETAIL |
| P-701 - PLUMBING RISER DIAGRAM |
| PD102 - FIRST FLOOR PLUMBING REMOVALS PLAN - EAST |
File details come from the government source that posted it. Updated .