CN-370000-HW685-DC009A.pdf
PDF 4 MB Posted
- Contract number
- HW685
- Issued by
- Florida
About this file
This document package comprises a Task Assignment (TA) issued by the State of Florida Department of Environmental Protection (FDEP) to Golder Associates USA Inc., a consulting firm, for groundwater monitoring services at the Former Lake Lucina Drycleaners site in Jacksonville, Duval County, Florida. The TA number DC009A is issued under the indefinite delivery vehicle contract HW685 and is part of Florida's Drycleaning Solvent Cleanup Program. The project involves coordination between FDEP project manager Ben Grubbs and contractor project manager Matt Crews, with William E. Burns, Jr. serving as FDEP Secretary or Designee for authorization.
The Task Assignment authorizes Golder to conduct annual groundwater monitoring activities including sampling from 33 monitoring and injection wells at various depths (shallow, intermediate, and deep zones), water level measurements, field parameter recording, laboratory analysis for chlorinated volatile organic compounds (VOCs), total organic carbon (TOC), and dissolved gases, and investigation-derived waste (IDW) treatment and disposal. The total contract value is $20,836.03, structured as a fixed unit rate with two invoice milestones: $14,699.48 due upon submittal and FDEP approval of groundwater monitoring field documentation and laboratory reports (due May 31, 2022), and $6,136.55 due upon submittal and approval of the annual groundwater monitoring report and data updates (due June 30, 2022). The project completion date is August 31, 2022. Labor costs total $12,293.60, with subcontractor costs including $200 for IDW disposal via Erwin Remediation, laboratory analytical costs of $4,689.00, field equipment and supplies of $1,814.00, and vehicle rental of $480.00, supplemented by a completion fee of $1,239.37.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Funding Information:
Org. Code E.O. Object Code Budget Entity Appropriation
Category Grant # Project # Year Amount
☐ Additional Funding Information attached on separate page.
Rev. 8/26/2020
STATE OF FLORIDA
DEPARTMENT OF ENVIRONMENTAL PROTECTION
Task Assignment This Task Assignment (TA) is entered into between the Parties named below, pursuant to Contract Number: .
1. TA Number: TA Completion Date:
TA Description:
2. Parties State of Florida Department of Environmental Protection
(Department)
Department Project Manager: Department Project Manager Phone:
Contractor Name: (Contractor ) ntractor’st ’s Project Manager: ontractor’s t’s Project Manager Phone:
3. Project Number:
(If different from TA Number)
Project Location(s):
Project Name:
4. As consideration for the services rendered by Contractor under the terms of this TA, the Department shall pay the Contractor on the following bases, up to the Total TA Value as indicated below:
☐ Fixed Price:
☐ Fixed Unit Rate: (Extended Price)
☐ Cost Reimbursement:
Total TA Value:
5. The Parties agree to comply with the terms and conditions of the underlying the Contract, and the following attachments which are hereby incorporated by reference:
Attachment 1:
☐ Additional Attachments (if necessary):
IN WITNESS WHEREOF, this TA shall be effective on the last date signed below.
State of Florida Department of Environmental Protection CONTRACTOR Department Name:
Title:
Secretary or Designee
(Authorized Signature) (Authorized Signature) Date:
☐ Additional signatures attached on separate page.
HW685
DC009A Completion August 31, 2022
This Task Assignment authorizes Golder to conduct groundwater monitoring activities in accordance with the March 18, 2022, Scope of Work, Cost Estimate, and Bid Documentation.
Ben Grubbs 850-245-8992 Contractor Contractor
Contractor Contractor
Contractor Contractor
Contractor
Golder Associates USA Inc.
Golder Associates USA Inc.
Matt Crews 904-363-3430
ERIC_4610
6054 Merrill Road, Jacksonville, Duval County
Lake Lucina Shopping Center
✔ $ 20,836.03
$ 20,836.03
Scope of Work
Donald Miller
Principal
Donald Miller Digitally signed by Donald Miller Date: 2022.04.06 13:01:59 -04'00'
William E. Burns, Jr.
William E. Burns, Jr. Digitally signed by William E. Burns, Jr.
Date: 2022.04.06 11:16:45 -04'00'
N/A
Task Assignment Notification/Change Order Deliverables and Invoice Schedule Attachment
WCP TAFORM 04-2017
Contract Number:
Task Assignment #:
Deliverables:
Deliverable Deliverable Due Date
Invoice Schedule:
Requirements for Invoice Submittal Amount to be Invoiced
TOTAL COST
Subtask 2: Groundwater Monitoring Field Documentation and Laboratory Report;
IDW Disposal Documentation 05/31/2022
Subtasks 1 & 3: Annual Groundwater Monitoring Report; ADaPT/GIS Update; Project Management 06/30/2022
Subtask 2: Submittal and FDEP approval of the Groundwater Monitoring Field Documentation and Laboratory Report; IDW Disposal Documentation $ 14,699.48
Subtasks 1 & 3: Submittal and FDEP approval of the Annual Groundwater Monitoring Report; ADaPT/GIS Update; Project Management $ 6,136.55
$ 20,836.03
HW685
DC009A
Printed on recycled paper.
FLORIDA DEPARTMENT OF
Environmental Protection
Bob Martinez Center
2600 Blair Stone Road Tallahassee, FL 32399-2400
Ron DeSantis Governor
Jeanette Nuñez
Lt. Governor
Shawn Hamilton Secretary
To: HW685 Contract Negotiation File Lake Lucina Shopping Center Jacksonville, Duval County
ERIC_ 4610
From: Ben Grubbs, Project Manager Date: April 5, 2022 Subject: Negotiation Summary
HW561 DC009A
This Task Assignment authorizes Golder to conduct groundwater monitoring activities in accordance with the March 18, 2022, Scope of Work, Cost Estimate, and Bid Documentation.
Subtask 1: Project Management An automatic calculation based upon total direct labor hours determines the labor hours within this subtask.
Subtask 2: Annual Groundwater Monitoring and IDW Treatment Golder will collect groundwater samples from monitoring wells MW001 – MW007, MW012 – MW022, MW024 – MW030, IW001, IW002, IW004, IW007, IW008, IW012, IW022, and IW023. Prior to sampling, depth-to-water will be measured. The wells will then be purged, and field parameters will be recorded. The groundwater samples will be collected using low flow sampling methods and analyzed for chlorinated volatile organic compounds (VOCs). Twelve samples will also be analyzed for total organic carbon (TOC), and eight samples will also be analyzed for dissolved gases. Investigation-derived waste (IDW) will be temporarily stored in a 55-gallon drum. Golder requested bids for IDW drum treatment and disposal from Clark, Erwin, Whatever Waste, and M & D Industrial Services. Erwin was selected as the lowest responsive and responsible bidder.
Subtask 4: Reporting Golder will submit the Annual Groundwater Monitoring Report and ADaPT and GIS deliverables to FDEP.
Golder and the FDEP confirmed on March 18, 2022, that an Access Agreement with the current real property owner of the Lake Lucina Shopping Center (ERIC_4610) site has been executed.
The FDEP Project Manager agrees to the scope of work and final cost associated with this Task Assignment. The final cost for this Task Assignment is $20,836.03 with 111 labor hours.
MEMORANDUM
Lake Lucina Shopping Center April 5, 2022 Page Two
Golder may invoice following the schedule established in the Deliverables and Invoice Schedule Attachment, which accompanies the Task Assignment Notification Form.
FDEP COST ESTI MATEContractor: Golder Associates USA Inc.
Date: 3/23/2022
Task #: DC009A SubTask 1 Project Management SubTask 6
Site: SubTask 2 Annual GW Monitoring SubTask 7
Activity/Phase: Assessment SubTask 3 Reporting SubTask 8
Project Manager: Ben Grubbs SubTask 4 SubTask 9
SubTask 5 SubTask 10
Totals 1 2 3 4 5 6 7 8 9 10 Labor Rate Category
$51.23 Project Manager (RFM) 10 10.2 $0.00 Program Leader - X-14 0 0 0 0 0 0 0 0 0 0
$63.65 Practice Leader - X-13 (JB) 4 1 3 0 0 0 0 0 0 0 $0.00 Senior Consultant - X-12 0 0 0 0 0 0 0 0 0 0
$51.23 Senior Sci/Eng - X-11 (RFM) 24 8 16 0 0 0 0 0 0 0 $45.42 Senior Project Sci/Eng - P-10 (BL) 5 0 5 0 0 0 0 0 0 0 $44.15 Project Sci/Eng - P-10 (JT) 5 0 5.0 0 0 0 0 0 0 0 $33.32 Staff Sci/Eng - P-8 (JS) 31 31 0 0 0 0 0 0 0 0 $33.15 Staff Sci/Eng - P-8 (KF) 30 30 0 0 0 0 0 0 0 0 $32.75 Staff Sci/Eng - P-8 (AS) 2 0 2 0 0 0 0 0 0 0
$0.00 Sci/Eng/Admin - P-7 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0
$0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0
Total Hours 111 10.2 70.0 31.0 0 0 0 0 0 0 0
Direct Labor $4,548.13 $523.24 $2,500.91 $1,523.98 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Overhead 172.50% $7,845.53 $902.59 $4,314.07 $2,628.87 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Gen & Admin 0.00% $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Fringe 0.00% $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Total Labor $12,393.66 $1,425.83 $6,814.98 $4,152.85 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Former Lake Lucina Drycleaners
REV: 02/03 CEF GOLDER Page 1
FDEP COST ESTI MATEContractor: Golder Associates USA Inc.
Date: 3/23/2022
Task #: DC009A SubTask 1 Project Management SubTask 6
Site: SubTask 2 Annual GW Monitoring SubTask 7
Activity/Phase: Assessment SubTask 3 Reporting SubTask 8
Project Manager: Ben Grubbs SubTask 4 SubTask 9
SubTask 5 SubTask 10
Totals 1 2 3 4 5 6 7 8 9 10
Former Lake Lucina Drycleaners
Travel Vehicle Rental $480.00 $480.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Mileage Costs $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Air Fare $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Per diem + Hotel $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Total Travel $480.00 $480.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Subcontractor (Equipment Procurement) $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
$0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Subcontractor Subtotal $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Procurement Fee $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Total Subcontractor Cost $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Subcontractor (Services Procurement) Drilling (Conventional) $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Drilling (Non-conventional) $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Mobile Laboratory $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Surveying $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
IDW $200.00 $200.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Utilities $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Utility Location $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
$0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Subcontractor Subtotal $200.00 $200.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Handling Fee $20.00 $20.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Total Subcontractor Cost $220.00 $220.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Laboratory Analytical Costs $4,319.00 $4,319.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Fast Turnaround Charges $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Sample Shipping $370.00 $370.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Total Laboratory $4,689.00 $4,689.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Field Expenses Personal Protection $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Expendables $120.00 $120.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Equipment (Drilling related) $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Equipment (Analytical related) $1,494.00 $1,494.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Equipment (IDW related) $200.00 $200.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Equipment (Other) $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Total Field Expenses $1,814.00 $1,814.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Subtotal $19,596.66 $1,425.83 $14,017.98 $4,152.85 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Completion Fee $1,239.37 $142.58 $681.50 $415.29 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Total Estimated Cost $20,836.03 $1,568.41 $14,699.48 $4,568.14 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
REV: 02/03 CEF GOLDER Page 2
LEVEL OF EFFORT/EXPENSE WORKSHEET
SITE : Former Lake Lucina Drycleaners SUBTASK 2: Annual GW Monitoring
DATE: 3/23/2022
LABOR CATEGORY *PROVIDE TIME REQUIRED FOR EACH PERSON
STAFF-TITLE WORK DESCRIPTION HOURS
Senior Sci/Eng (R Mongillo) 8
Staff Sci/Eng (J. Spengler) 31
Project Sci/Eng (K. Fraley) 30
Practice Leader (J. Brown) 1
TOTAL LABOR 70
VEHICLE TYPE RATE UNIT USEAGE
Truck (GW sampling $120.00 Per Day 4 $480.00
TOTAL VEHICLE $480.00
PER DIEM STAFF RATE UNIT USEAGE
TOTAL PER DIEM $0.00
SUBCONTRACTOR COSTS
NAME PURPOSE COST
Erwin IDW T&D - Liquids $100.00 Per Drum 2 $200.00
TOTAL $200.00
LABORATORY COSTS
PARAMETER RATE # SAMPLES #QAQC
Chlorinated VOCs - EPA Method 8260B Total VOHs EPA Method 8260B $73.00 33 $2,409.00 Total Organic Carbon EPA Method 9060/SM5310B $30 12 $360.00 MEE Dissolved Gases (RSK175) $180.00 8 $1,440.00 Total VOCs (IDW) EPA Method 8260B $110.00 1 $110.00 Sample Shipping Small $110.00 2 $220.00 Sample Shipping Large $150.00 1 $150.00
TOTAL LAB $4,689.00
EQUIPMENT ITEM RATE COSTING UNIT USEAGE TOTALS
Miscellaneous Expendables $40.00 Per Day 3 $120.00 Shallow Groundwater Sampling Kit $290.00 Per Day 3 $870.00 Tubing, Poly HDPE $0.30 Per Foot 1750 $525.00 Tubing, Silicon 3/16 x 3/8 $3.00 Per foot 33 $99.00 Drum, 55-gallon $100.00 Per Drum 2 $200.00
TOTAL EQUIPMENT $1,814.00
Annual Monitoring Event. Mobilize and collect samples from 33 wells (Shallow: MW-001, MW-003, MW-017, MW-018, MW 019, MW-020, MW-021, MW-022, MW-024, MW-025, MW-027, MW-028, MW-029, MW-030, IW001, IW002, IW004, IW007, IW008, IW012, IW022, and IW023); Intermediate: MW-002, MW-004, MW-005, MW-012, MW-014, MW-015, MW-026;
Deep MW-006, MW-007, MW-013, MW-016). Water levels, instrument calibration, and sampling (9 hours per day x 3 days = 27 hours). Field event preparation (1 hour). Three round
Communication with RPO (verification of property ownership) and offsite property owners for site access (2 hrs), prepare and submit field notes, sample forms, laboratory report and updated tables and figures in an email deliverable to the DEP with comments (4 hours), and characterization and waste profile for transportation and disposal of IDW drum(s) (2 hours).
Finalize tables and figures for DEP deliverable preparing initial comments about the results.
Annual Monitoring Event. Mobilize and collect samples from 33 wells (Shallow: MW-001, MW-003, MW-017, MW-018, MW 019, MW-020, MW-021, MW-022, MW-024, MW-025, MW-027, MW-028, MW-029, MW-030, IW001, IW002, IW004, IW007, IW008, IW012, IW022, and IW023); Intermediate: MW-002, MW-004, MW-005, MW-012, MW-014, MW-015, MW-026;
Deep MW-006, MW-007, MW-013, MW-016). Water levels, instrument calibration, and sampling (9
FINAL --7/24/96
LEVEL OF EFFORT/EXPENSE WORKSHEET
SITE : Former Lake Lucina Drycleaners SUBTASK 3: Reporting
DATE: 3/23/2022
LABOR CATEGORY *PROVIDE TIME REQUIRED FOR EACH PERSON
STAFF-TITLE WORK DESCRIPTION HOURS
Practice Leader (J. Brown) 3 Senior Sci/Eng (R Mongillo) 16
Senior Project Sci/Eng (J. Thomas) 5
Senior Project Sci/Eng (B. Lucero) 5 Staff Sci/Eng (A. Strayer) 2
TOTAL LABOR 31
VEHICLE TYPE RATE UNIT USEAGE
TOTAL VEHICLE $0.00
PER DIEM STAFF RATE UNIT USEAGE
TOTAL PER DIEM $0.00
SUBCONTRACTOR COSTS
NAME PURPOSE COST
TOTAL $0.00
LABORATORY COSTS
PARAMETER RATE # SAMPLES #QAQC
TOTAL LAB $0.00
EQUIPMENT ITEM RATE COSTING UNIT USEAGE TOTALS
TOTAL EQUIPMENT $0.00
Reporting: Updating tables, document production, binding and shipping. Create pdf for OCULUS.
Develop conclusions and recommendations and prepare final Annual Monitoring Report.
Data entry, prepare tables and figures, and draft Annual Monitoring Report Update FDEP GIS Tables, run data checker, create and edit error report, and annotate error report (33 data points x 8 min/point = 264 minutes). Submit FDEPGIS tables; submit ADaPT deliverable (0.5) CADD Update Figures (four groundwater flow and five CVOC detections) for the report.
FINAL --7/24/96
Golder Associates USA Inc.
9428 Baymeadows Road, Suite 400, Jacksonville, Florida, USA 32256
T: +1 904 363-3430 F: +1 904 363-3445 golder.com
March 18, 2022 Proposal No. 202208346
Mr. Ben Grubbs Florida Department of Environmental Protection Division of Waste Management Drycleaning Solvent Cleanup Program 2600 Blair Stone Road, MS 4520 Tallahassee, FL 32399-2400
RE: COST PROPOSAL FOR THE FORMER LAKE LUCINA DRYCLEANERS
ANNUAL GROUNDWATER MONITORING
6054 MERRILL ROAD
JACKSONVILLE, DUVAL COUNTY, FLORIDA
DEP FACILITY ID NUMBER: ERIC_4610
PROPOSED TASK ASSIGNMENT: HW685_DC009A
Dear Mr. Grubbs:
Golder Associates USA Inc. (Golder) is pleased to provide the Florida Department of Environmental Protection (DEP) with this cost proposal for annual groundwater monitoring at the above-referenced site. This proposal includes a description of the proposed scope of services, level of effort sheets for each subtask, and a cost estimate form that summarizes the costs of the proposed services. The proposed scope of services is described below.
SUBTASK 1 – PROJECT MANAGEMENT
To facilitate project quality and satisfactory completion of the proposed scope of work, all aspects of this project will be overseen by an experienced project manager. The project manager will be responsible for the schedule, budget, invoicing, project activities, and communications with DEP and the field team. Project management will include coordination of field activities; resource allocation to confirm the work is conducted by qualified professionals in accordance with the project schedule; cost control and tracking of the budget status; and submittal of project invoices in accordance with DEP Drycleaning Solvent Cleanup Program requirements. The project manager will oversee the work so that it is conducted in a manner that is consistent with the requirements of the DEP-approved task assignment.
SUBTASK 2 – ANNUAL GROUNDWATER MONITORING AND IDW TREATMENT
Golder will collect groundwater samples from 22 monitoring/injection wells screened in the shallow zone of the surficial aquifer (MW-001, MW-003, MW-017, MW-018, MW 019, MW-020, MW-021, MW-022, MW-024, MW-025, MW-027, MW-028, MW-029, MW-030, IW001, IW002, IW004, IW007, IW008, IW012, IW022, and IW023);
seven downgradient offsite wells screened in the intermediate zone of the surficial aquifer (MW-002, MW-004, MW-005, MW-012, MW-014, MW-015, and MW-026); and four downgradient offsite wells screened in the deep
Mr. Ben Grubbs Proposal No. 202208346
Florida Department of Environmental Protection March 18, 2022 zone of the surficial aquifer (MW-006, MW-007, MW-013, and MW-016). The following monitoring wells will be used as temporary point-of-compliance (TPOC) monitoring wells: MW-013 (deep), MW-014 (intermediate), MW-016 (deep), MW-022 (shallow), and MW 024 (shallow). Figures 5 through 8 from the previous groundwater monitoring report are attached for reference.
Prior to groundwater sampling, depth-to-water measurements will be collected using an electronic water level indicator to determine groundwater depth. During the sampling event, the locks and well caps will be inspected for damage or degradation and repaired or replaced, as necessary.
Groundwater samples will be collected from the wells in accordance with DEP Standard Operating Procedures (SOPs) for Field Activities (DEP SOP-001/01). Prior to collecting the groundwater sample, each well will be purged and field parameters including temperature, pH, specific conductance, dissolved oxygen, turbidity, and oxidation reduction potential (ORP) will be monitored. Purge volumes and field parameters will be recorded on field data sheets, and the field monitoring equipment will be calibrated in accordance with the manufacturer’s recommended procedures.
Groundwater samples will be collected using low flow sampling methods. The groundwater samples will be placed in laboratory-supplied containers, labeled with a unique identification number attached to the outside of the sample container, preserved on ice in a laboratory-provided cooler at a maximum temperature of four degrees Celsius, and delivered to a Florida Department of Health and National Environmental Laboratory Accreditation Program certified fixed-base laboratory along with the completed chain-of-custody documentation to be analyzed in accordance with the monitoring plan shown in Table 1. In addition, twelve samples will be collected for Total Organic Carbon (Method SM5310B) and eight samples will be collected for Dissolved Gases (Method RSK175) analyses at the monitoring wells identified on Table 1. Upon receipt of the laboratory analytical results, Golder will evaluate the constituent concentrations to determine if off-site notification is required.
Golder will temporarily store the investigation derived waste (IDW) purge water generated from the groundwater sampling event in a 55-gallon steel drum(s). A waste characterization sample will be collected from the IDW drum(s) for analysis of total VOCs using EPA Method 8260. If the waste characterization sample is acceptable to the disposal subcontractor, the IDW drum(s) will be picked up and transported to a facility for proper disposal. A non-hazardous waste manifest will be provided by the disposal subcontractor upon delivery to the disposal facility.
Upon completion of Subtask 2, an e-mail deliverable will be submitted and include copies of the field data sheets, equipment calibration forms, field notes, laboratory analytical report, and laboratory chain-of-custody documentation.
SUBTASK 3 – REPORTING
The annual groundwater monitoring report will include a description of the sampling procedures, evaluation of the analytical results, comparison of current to historical data, tabulated summary of the current and historical analytical data, a site map showing the groundwater analytical results, water level elevation information in tables and figures, laboratory analytical data, conclusions, and recommendations. Golder will also update the DEP GIS tables with the new water level data, field parameter measurements, and VOC data; run the DEP data checker on the completed tables; and submit the updated tables and error reports under this subtask. Additionally, Golder will forward the Automated Data Processing Tool (ADaPT) data deliverables for the groundwater sampling event provided by the laboratory.
HEALTH AND SAFETY
Golder will update the existing site-specific Health and Safety Plan for the field work. The work will be completed in accordance with Golder’s safety policies and procedures. At a minimum, Golder will wear safety glasses, high visibility safety vests, and steel-toed boots. A safety job briefing will be conducted prior to the start of work activities, and anytime the scope of work or site conditions change.
COST AND SCHEDULE
The estimated cost to complete the proposed scope of work is $20,197.46. Golder anticipates the monitoring event will take place in late April or middle May 2022. The LOE/CEF sheets are included in Attachment A. Disposal subcontractor IDW quotes are included in Attachment B. The following table summarizes the proposed costs and deliverable schedule.
Task Proposed Cost Proposed Schedule/Deliverables
Subtask 1 – Project Management $1,494.94 July 30, 2022
Subtask 2 – Annual Groundwater Monitoring
$14,337.71 May 30, 2022 (Field documentation and laboratory analytical report via E-mail)
Subtask 3 – Reporting $4,364.81 June 30, 2022 (Annual Groundwater Monitoring Report)
Total/Completion Date $20,197.46 August 31, 2022
Please be aware that Golder has been acquired by and is now a Member of the WSP family of companies. Golder remains as a legal entity and is the proposed contracting entity for this proposal. We are in the process of integrating the resources of our companies. Correspondence for this proposal should continue to be addressed to the undersigned.
Golder appreciates the opportunity to provide services under the Drycleaning Solvent Cleanup Program. Should you require additional information or clarifications, please contact us at (904) 363-3430.
Sincerely, Golder Associates USA Inc.
Ralph F. Mongillo, Jr., PG Jesse C. Brown, PE Lead Consultant / Senior Geologist Director, Environmental Engineer
RFM/JCB/as
Attachments: Table 1 – 2022 Annual Groundwater Monitoring Plan
Figure 5 – Groundwater Characterization in the Shallow Zone of the Surficial Aquifer
– NADC Treatment Area Figure 6 – Groundwater Characterization in the Shallow Zone of the Surficial Aquifer Figure 7 – Groundwater Characterization in the Intermediate Zone of the Surficial Aquifer Figure 8 – Groundwater Characterization in the Deep Zone of the Surficial Aquifer
Attachment A Level of Effort Sheets and Cost Estimate Form Attachment B Subcontractor Quotes
G:\Projects\DEP-Drycleaning\Projects\Jax\Lake Lucina - HW685\Proposal\HW685 Lake Lucina Annual GW Monitoring proposal.docx
March 2022 202208346
Well ID Screen Interval
(ft) Chlorinated VOCs TOC Dissolved Gases Turbidity COND DO Temp pH ORP
EPA Method 8260 Method SM5310B Method AM20GAX
MW-001 13 - 18 X X -- X X X X X X
MW-003 13 - 18 X X -- X X X X X X
MW-017 12 - 17 X X X X X X X X X
MW-018 11 - 16 X X X X X X X X X
MW-019 12 - 17 X -- -- X X X X X X
MW-020 13 - 18 X X X X X X X X X
MW-021 11 - 16 X -- -- X X X X X X
MW-022 12 - 17 X -- -- X X X X X X
MW-024 10 - 20 X -- -- X X X X X X
MW-025 10 - 20 X -- -- X X X X X X
MW-027 10 - 20 X -- -- X X X X X X
MW-028 10 - 20 X X X X X X X X X
MW-029 10 - 20 X -- X X X X X X
MW-030 10 - 20 X -- -- X X X X X X
IW-002 10 - 20 X X -- X X X X X X
MW-002 33 - 38 X -- -- X X X X X X
MW-004 33 - 38 X -- -- X X X X X X
MW-005 23 - 28 X -- -- X X X X X X
MW-012 33 - 38 X -- -- X X X X X X
MW-014 33 - 38 X -- -- X X X X X X
MW-015 33 - 38 X -- -- X X X X X X
MW-026 33 - 38 X -- -- X X X X X X
MW-006 53 - 58 X -- -- X X X X X X
MW-007 58 - 63 X -- -- X X X X X X
MW-013 73 - 78 X -- -- X X X X X X
MW-016 73 - 78 X -- -- X X X X X X
IW-001 10 - 20 X X X X X X X X X
IW-004 8 - 20 X X X X X X X X X
IW-007 8 - 20 X X -- X X X X X X
IW-008 8 - 20 X -- -- X X X X X X
IW-012 8 - 20 X -- -- X X X X X X
IW-022 8 - 20 X X X X X X X X X
IW-023 8 - 20 X X X X X X X X X
Notes:
ft - feet X - Parameter measured or analyzed -- - not sampled or analyzed VOC - volatile organic compound TOC - Total Organic Carbon DO - Dissolved Oxygen ORP - Oxidation/Reduction Potential
Dissolved Gases - Methane, Ethane, Ethene
SHALLOW ZONE INJECTION WELLS
INTERMEDIATE ZONE MONITORING WELLS
DEEP ZONE MONITORING WELLS
2022 ANNUAL GROUNDWATER MONITORING PLAN
TABLE 1
Former Lake Lucina Drycleaners Jacksonville, Duval County, Florida
SHALLOW ZONE MONITORING WELLS
FN: Table 1 - Annual Mon Plan Page 1 of 1
ALLEY
OFFICE
KITCHEN
W O
M
EN
'S R
M
M
EN
'S R
M
RW-1
SVE EQUIPMENT
COMPOUND
TRAILER
TRAILER
FM004
FM001
FM005FM002
FM003
MW-021
MW-001
MW-002
MW-023
MW-022
MW-018
MW-017
MW-019
MW-025
MW-020
MW-003
MW-004
MW-027
MW-026
MW-030
MW-028
MW-029
IW017
IW018
IW016
IW015
IW014IW013
IW010 IW011
IW012
IW008
IW009
IW007IW006
IW005
IW004
IW001
IW002
IW003
IW024
IW023
IW019
IW020
IW021
IW022
FORMER DRYCLEANER LOCATION
CURRENT BUILD-OUT
in
FDEP-DC019
Control No.
FDEPDC019-ZA005
FIGURE
2021-03-11
BCL
RFM
RFM
JCB
LAKE LUCINA
JACKSONVILLE, DUVAL COUNTY, FLORIDA
FL. DEPT. OF ENVIRONMENTAL PROTECTION
GROUNDWATER CHARACTERIZATION IN THE SHALLOW ZONE
OF THE SURFICIAL AQUIFER - NADC TREATMENT AREA
TITLE
PROJECT NO. REV.
PROJECTCLIENT
CONSULTANT
PREPARED
DESIGNED
REVIEWED
APPROVED
YYYY-MM-DD
IF
T
H
IS
M
EA
SU
R
EM
EN
T D
O
ES
N O
T M
AT
C
H W
H
AT
IS
S
H O
W N
, T H
E
SH
EE
T
SI
ZE
H
AS
B
EE
N M
O D
IF
IE
D F
R O
M : A
N
SI
B
Pa th
\g ol de r.g ds
\c om pl ex da ta
\O ffi ce \J ac ks on vi lle \d ra fti ng \F ile \F
D
EP
\F D
EP
-D
C \D
C N o
La ke L uc in a\
ZA
A nn ua l G W
M R
\A ct iv e
D ra w in gs
Fi le N am e:
F D
EP
D
C
9-
ZA
5.
dw g
NOTE(S)
1. ALL RESULTS ARE REPORTED IN MICROGRAMS PER LITER (µg/L).
2. U - INDICATES THE COMPOUND WAS ANALYZED FOR BUT NOT DETECTED. THE
VALUE SHOWN IS THE METHOD DETECTION LIMIT.
3. I - THE REPORTED VALUE IS BETWEEN THE LABORATORY METHOD DETECTION
LIMIT AND THE LABORATORY PRACTICAL QUANTITATION LIMIT.
4. GCTL - GROUNDWATER CLEANUP TARGET LEVEL PER CHAPTER 62-777, TABLE I,
OF THE FLORIDA ADMINISTRATIVE CODE (FAC).
5. NADC - NATURAL ATTENUATION DEFAULT CONCENTRATION PER CHAPTER
62-777, TABLE V, OF THE FAC.
6. BOLD FONT AND YELLOW SHADED CELL INDICATES AN EXCEEDANCE OF THE
APPLICABLE GCTL.
7. BOLD FONT AND BLUE SHADED CELL INDICATES AN EXCEEDANCE OF THE
APPLICABLE NADC.
8. ISOCONCENTRATION CONTOURS DASHED WHERE INFERRED.
9. V - INDICATES THE ANALYTE WAS DETECTED IN BOTH THE SAMPLE AND
ASSOCIATED METHOD BLANK.
SCALE
0 15 30
FEET
REFERENCE(S)
1. AERIAL IMAGE TAKEN FROM FDEP BUREAU OF SURVEY AND MAPPING (LAND
BOUNDARY INFORMATION SYSTEM 2013).
MONITORING WELL LOCATION
EXISTING RECOVERY WELL LOCATION
FLUXMETER MONITORING WELL LOCATION
INJECTION WELL LOCATION
WELL INCLUDED IN THE INJECTION PROGRAM
MW-008
7/14 10/14
3 300 3 300
70 700 1 100
WELL I.D.
DATE SAMPLED
TETRACHLOROETHENE (PCE)
TRICHLOROETHENE (TCE)
cis-1,2-DICHLOROETHENE (DCE)
VINYL CHLORIDE
IW004
FM004
RW-1
MW-020
IW-001
7/14 2/18 03/20 02/21 708 3,370 5,550 2,860 176 420 1,560 826
59.7 6,980 11,900 11,100
3.3 U 963 870 1,430
FM005
7/14 7.0 1.4
0.33 U
0.33 U
IW-002
2/18 3/19 03/20 02/21 330 109 437 187 28 10.3 50.5 12.3 48 31.1 55 25.3 31 3 9.5 2.9
FM004
7/14 4.3 2.3
0.33 U
IW007
2/18 03/19 03/20 02/21
0.50 U 0.38 U 1.7 19 U
0.50 U 0.53 I 25 18 U
0.92 I 75.2 4,890 1,110
6.5 103 2,250 3,420
IW008
2/18 03/19 03/20 02/21
0.50 U 0.38 U 4.7 290
0.50 U 0.36 I 25.4 432
0.50 U 86.7 2,120 1,910
1.4 147 716 194
IW004
2/18 03/19 03/20 02/21
6.4 0.38 U 630 7,980
2.7 7.7 125 1,500
262 1,960 2,260 1,860
318 986 515 91.4
RW-1
7/14 97.2 4.2 2.7
0.33 U
IW012
2/18 3/19 03/20 02/21
0.50 U 0.38 U 0.50 U 1.8
0.50 U 0.36 U 0.50 U 0.36 U
4.1 0.27 U 17.2 6.9
6.1 0.39 U 28.8 9.0
IW018
7/14 0.80
0.82 U
0.81 U
IW015
7/14 7/16
1,350 1.5 U
8.9 1.4 U
8.2 U 196
8.1 U 294
IW010
7/14 3/15
1,340 9.4 I
9.6 5.8
9.1 3,200
6.5 U 0.68 I
FM002
7/14 2/18 3/19
4.5 17 3.6
2.9 3.7 I 0.48 I
2.5 1.8 I 0.27 U
0.33 U 1.8 U 0.39 U
APPROXIMATE PROPERTY BOUNDARY
MW-029
2/18 3/19 03/20 02/21
0.22 U 0.38 U 1.9 3.1
0.36 U 0.36 U 3.8 3.5
19 206 61.1 169
0.36 U 79.3 77.9 1,260
MW-028
2/18 03/19 03/20 02/21
0.24 I 0.38 U 6.2 15.4
0.36 U 0.36 U 36.7 10.5
1.9 0.27 U 187 173 36 0.39 U 236 428
MW-027
2/18 3/19 03/20 02/21
0.52 I 4.0 0.50 U 1.2
0.36 U 1.7 0.50 U 0.36 U
0.36 U 0.27 U 0.50 U 0.27 U
0.36 U 0.39 U 0.50 U 0.39 U
IW-024
7/16
6.8 I
IW-023
7/16 2/18 03/20 02/21
3,690 73.4 1,450 1,550
40.0 I 26.4 71.4 1,220
16 U 2,690 2,160 2,350 16 U 625 581 184
MW-030
2/18 3/19 03/20 02/21
1,100 145 1,040 754
7.9 I 0.52 I 1.7 1.5
8.4 I 0.27 U 0.50 U 0.37 I
3.6 U 0.39 U 0.50 U 0.46 I
IW-022
2/18 03/19 03/20 02/21 112 3.8 U 10,000 423 187 13.6 4,490 241
1,190 4,820 5,020 748 515 6.4 I 759 876
IW-020
7/16 2/18
92.1 0.50 U
58.4 0.50 U 4,540 3.3 2,330 30.7
MW-021
2/18 3/19 03/20 02/21
2,000 1,290 987 1,140 72 47.9 56.8 64.5 83 103 166 139
7.2 U 4.7 8.1 24.1
MW-017
2/18 3/19 03/20 02/21
27,000 27,100 29,600 18,600 3,100 2,670 2,160 597 3,500 1,110 378 221 72 I 2.8 0.89 I 3.2
MW-022
2/18 3/19 03/20 02/21
1,200 1,120 737 836 60 42.7 26.6 47.7
150 106 73.6 80.8 94 23.2 3.3 4.9
MW-001
2/18 3/19 03/20 02/21
0.29 I 0.38 U 1.0 1.9 U
1.2 0.68 I 2.3 1.8 U
4.7 70.0 52.7 158
24 93.8 349 367
MW-018
2/18 3/19 03/20 02/21
1,000 2,010 2,760 2,130 400 618 698 592
9,300 5,910 6,190 4,260 1,300 504 603 588
MW-025
2/18 3/19 03/20 02/21 180 129 664 29.7
2.2 I 1.6 7.5 3.2
3.3 I 4.2 7.1 3.3
1.8 U 0.39 U 0.39 U 0.39 U
MW-020
2/18 03/19 03/20 02/21
69,000 63,400 73,300 87,300 360 U 500 U 532 602 990 I 4,630 4,720 7,370 360 U 179 266 251
MW-003
2/18 3/19 03/20 02/21
7,000 2,580 1,490 434 3,100 818 938 243 7,200 5,090 2,130 635 350 104 41.7 39.1
MW-019
2/18 3/19 03/20 02/21
7.2 5.2 4.9 6.2
0.36 U 0.39 I 0.50 U 0.36 U
0.36 U 0.27 U 0.50 U 0.27 I
0.36 U 0.39 U 0.50 U 0.39 U
ESTIMATED EXTENT OF VOC NADC
EXCEEDANCES (300 µg/L PCE/TCE)
GCTLs NADCs
LEGEND
SWIFT
CLEANERS
FORMER
SHELL
STATION
BP
STATION
ALLEY
MERRIL ROAD
R
ED
O
AK
D R
IV
E
BL
U
EB
ER
R Y
LA
N
E
O
AK
S U
M M
IT
D
R
IV
EC
ES
ER
Y
BO
U
LE
VA
R D
OFFICE
KITCHEN
W O
M
EN
'S R
M
M
EN
'S R
M
MW-009
MW-010
MW-011
TC
E
1,2-D C
E
TRAILER
PCE
MW-001
MW-002
MW-021
MW-023
MW-022
MW-018
MW-017
MW-019 MW-025
MW-020
MW-003MW-004
MW-012
MW-005
MW-006
MW-013MW-014
MW-008
MW-007
MW-015
MW-016
MW-024
MW-029
MW-028
MW-027
MW-030
VC
FORMER DRYCLEANER LOCATION
CURRENT BUILD-OUT
in
FDEP-DC019
Control No.
FDEPDC019-ZA006
FIGURE
2021-03-11
BCL
RFM
RFM
JCB
LAKE LUCINA
JACKSONVILLE, DUVAL COUNTY, FLORIDA
FL. DEPT. OF ENVIRONMENTAL PROTECTION
GROUNDWATER CHARACTERIZATION IN THE SHALLOW ZONE
OF THE SURFICIAL AQUIFER
TITLE
PROJECT NO. REV.
PROJECTCLIENT
CONSULTANT
PREPARED
DESIGNED
REVIEWED
APPROVED
YYYY-MM-DD
IF
T
H
IS
M
EA
SU
R
EM
EN
T D
O
ES
N O
T M
AT
C
H W
H
AT
IS
S
H O
W N
, T H
E
SH
EE
T
SI
ZE
H
AS
B
EE
N M
O D
IF
IE
D F
R O
M : A
N
SI
B
Pa th
\g ol de r.g ds
\c om pl ex da ta
\O ffi ce \J ac ks on vi lle \d ra fti ng \F ile \F
D
EP
\F D
EP
-D
C \D
C N o
La ke L uc in a\
ZA
A nn ua l G W
M R
\A ct iv e
D ra w in gs
Fi le N am e:
F D
EP
D
C
9-
ZA
6.
dw
VALUE SHOWN IS THE METHOD DETECTION LIMIT.
3. I - THE REPORTED VALUE IS BETWEEN THE LABORATORY METHOD DETECTION
LIMIT AND THE LABORATORY PRACTICAL QUANTITATION LIMIT.
4. GCTL - GROUNDWATER CLEANUP TARGET LEVEL PER CHAPTER 62-777, TABLE I,
OF THE FLORIDA ADMINISTRATIVE CODE (FAC).
5. NADC - NATURAL ATTENUATION DEFAULT CONCENTRATION PER CHAPTER
62-777, TABLE V, OF THE FAC.
6. BOLD FONT AND YELLOW SHADED CELL INDICATES AN EXCEEDANCE OF THE
APPLICABLE GCTL.
7. BOLD FONT AND BLUE SHADED CELL INDICATES AN EXCEEDANCE OF THE
APPLICABLE NADC.
8. ISOCONCENTRATION CONTOURS DASHED WHERE INFERRED.
SCALE
0 60 120
FEET
REFERENCE(S)
1. AERIAL IMAGE TAKEN FROM FDEP BUREAU OF SURVEY AND MAPPING (LAND
BOUNDARY INFORMATION SYSTEM 2013).
MONITORING WELL LOCATION
MW-008
7/14 10/14
3 300 3 300
70 700 1 100
WELL I.D.
DATE SAMPLED
TETRACHLOROETHENE (PCE)
TRICHLOROETHENE (TCE)
cis-1,2-DICHLOROETHENE (DCE)
VINYL CHLORIDE
MW-020
MW-009
1/99
0.6 U
1.8 U
1.0 U
0.6 U
MW-010
9/04 5/06 9/07 200 140 4.8
0.17 U 0.11 U 0.13 U
0.19 U 0.18 U 0.18 U
0.25 U 0.29 U 0.058 U
MW-023
11/00 9/04 5/06 9/07
16 0.17 U 0.50 I 0.24 U
1.0 U 0.17 U 0.11 U 0.13 U
1.0 U 0.19 U 0.18 U 0.18 U
1.0 U 0.25 U 0.29 U 0.058 U
MW-008
1/99 2/04 5/06 9/07
0.3 U 1.0 U 0.30 I 0.24 U
0.9 U 1.0 U 0.11 U 0.13 U
0.5 U 1.0 U 0.18 U 0.18 U
0.3 U 1.0 U 0.29 U 0.058 U
MW-024
2/18 3/19 03/20 02/21 32 31.9 163 53.3
1.7 1.5 9.1 2.8
0.36 U 0.27 U 2.1 0.38 I
0.36 U 0.39 U 0.39 U 0.39 U
ESTIMATED EXTENT OF VOC NADC
EXCEEDANCES (300 µg/L PCE/TCE)
ESTIMATED PCE ISOCONCENTRATION
CONTOUR (3 µg/L)
ESTIMATED TCE ISOCONCENTRATION
CONTOUR (3 µg/L)
ESTIMATED CIS-1, 2-DCE
ISOCONCENTRATION CONTOUR (70 µg/L)
APPROXIMATE PROPERTY
BOUNDARY
ESTIMATED VINYL CHLORIDE
ISOCONCENTRATION CONTOUR (1 µg/L)
LEGEND
GCTLs NADCs
ABANDONED WELL LOCATIONMW-009
MW-029
2/18 3/19 03/20 02/21
0.22 U 0.38 U 1.9 3.1
0.36 U 0.36 U 3.8 3.5
19 206 61.1 169
0.36 U 79.3 77.9 1,260
MW-028
2/18 03/19 03/20 02/21
0.24 I 0.38 U 6.2 15
0.36 U 0.36 U 36.7 10.5
1.9 0.27 U 187 173 36 0.39 U 236 428
MW-027
2/18 3/19 03/20 02/21
0.52 I 4.0 0.50 U 1.2
0.36 U 1.7 0.50 U 0.36 U
0.36 U 0.27 U 0.50 U 0.27 U
0.36 U 0.39 U 0.50 U 0.39 U
MW-030
2/18 3/19 03/20 02/21
1,100 145 1,040 754
7.9 I 0.52 I 1.7 1.5
8.4 I 0.27 U 0.50 U 0.37 I
3.6 U 0.39 U 0.50 U 0.46 I
MW-021
2/18 3/19 03/20 02/21 2,000 1,290 987 1,140
72 47.9 56.8 65 83 103 166 139
7.2 U 4.7 8.1 24.1
MW-017
2/18 3/19 03/20 02/21
27,000 27,100 29,600 18,600 3,100 2,670 2,160 597 3,500 1,110 378 221 72 I 2.8 0.89 I 3.2
MW-022
2/18 3/19 03/20 02/21
1,200 1,120 737 836 60 42.7 26.6 47.7
150 106 73.6 80.8 94 23.2 3.3 4.9
MW-001
3/19 03/20 03/20 02/21
0.38 U 1.0 1.0 1.9 U
0.68 I 2.3 2.3 1.8 U
70.0 52.7 52.7 158
93.8 349 349 367
MW-018
2/18 3/19 03/20 02/21
1,000 2,010 2,760 2,130 400 618 698 592
9,300 5,910 6,190 4,260 1,300 504 603 588
MW-025
2/18 3/19 03/20 02/21 180 129 664 29.7
2.2 I 1.6 7.5 3.2
3.3 I 4.2 7.1 3.3
1.8 U 0.39 U 0.39 U 0.39 U
MW-020
2/18 03/19 03/20 02/21
69,000 63,400 73,300 87,300 360 U 500 U 532 602 990 I 4,630 4,720 7,370 360 U 179 266 251
MW-003
2/18 3/19 03/20 02/21
7,000 2,580 1,490 434 3,100 818 938 243 7,200 5,090 2,130 635 350 104 41.7 39.1
MW-019
2/18 3/19 03/20 02/21
7.2 5.2 4.9 6.2
0.36 U 0.39 I 0.50 U 0.36 U
0.36 U 0.27 U 0.50 U 0.27 I
0.36 U 0.39 U 0.50 U 0.39 U
FORMER
SHELL
STATION
BP
STATION
ALLEY
MERRIL ROAD
R
ED
O
AK
D R
IV
E
BL
U
EB
ER
R Y
LA
N
E
O
AK
S U
M M
IT
D
R
IV
EC
ES
ER
Y
BO
U
LE
VA
R D
OFFICE
KITCHEN
W O
M
EN
'S R
M
M
EN
'S R
M
MW-009
MW-010
MW-011
MW-001
MW-002
MW-021
MW-023
MW-022
MW-018
MW-017
MW-019 MW-025
MW-020
MW-003
MW-004
MW-012
MW-005
MW-006
MW-013MW-014
MW-008
MW-007
MW-015
MW-016
MW-024
MW-026
MW-027
MW-028
MW-029
MW-030
TRAILER
FORMER DRYCLEANER LOCATION
CURRENT BUILD-OUT
in
FDEP-DC019
Control No.
FDEPDC019-ZA007
FIGURE
2021-03-11
BCL
RFM
RFM
JCB
LAKE LUCINA
JACKSONVILLE, DUVAL COUNTY, FLORIDA
FL. DEPT. OF ENVIRONMENTAL PROTECTION
GROUNDWATER CHARACTERIZATION IN THE INTERMEDIATE
ZONE OF THE SURFICIAL AQUIFER
TITLE
PROJECT NO. REV.
PROJECTCLIENT
CONSULTANT
PREPARED
DESIGNED
REVIEWED
APPROVED
YYYY-MM-DD
IF
T
H
IS
M
EA
SU
R
EM
EN
T D
O
ES
N O
T M
AT
C
H W
H
AT
IS
S
H O
W N
, T H
E
SH
EE
T
SI
ZE
H
AS
B
EE
N M
O D
IF
IE
D F
R O
M : A
N
SI
B
Pa th
\g ol de r.g ds
\c om pl ex da ta
\O ffi ce \J ac ks on vi lle \d ra fti ng \F ile \F
D
EP
\F D
EP
-D
C \D
C N o
La ke L uc in a\
ZA
A nn ua l G W
M R
\A ct iv e
D ra w in gs
Fi le N am e:
F D
EP
D
C
9-
ZA
7.
dw
VALUE SHOWN IS THE METHOD DETECTION LIMIT.
3. I - THE REPORTED VALUE IS BETWEEN THE LABORATORY METHOD DETECTION
LIMIT AND THE LABORATORY PRACTICAL QUANTITATION LIMIT.
4. GCTL - GROUNDWATER CLEANUP TARGET LEVEL PER CHAPTER 62-777, TABLE I,
OF THE FLORIDA ADMINISTRATIVE CODE (FAC).
5. NADC - NATURAL ATTENUATION DEFAULT CONCENTRATION PER CHAPTER
62-777, TABLE V, OF THE FAC.
6. BOLD FONT AND YELLOW SHADED CELL INDICATES AN EXCEEDANCE OF THE
APPLICABLE GCTL.
7. BOLD FONT AND BLUE SHADED CELL INDICATES AN EXCEEDANCE OF THE
APPLICABLE NADC.
8. ISOCONCENTRATION CONTOURS DASHED WHERE INFERRED.
SCALE
0 60 120
FEET
REFERENCE(S)
1. AERIAL IMAGE TAKEN FROM FDEP BUREAU OF SURVEY AND MAPPING (LAND
BOUNDARY INFORMATION SYSTEM 2013).
MONITORING WELL LOCATION
MW-008
7/14 10/14
3 300 3 300
70 700 1 100
WELL I.D.
DATE SAMPLED
TETRACHLOROETHENE (PCE)
TRICHLOROETHENE (TCE)
cis-1,2-DICHLOROETHENE (DCE)
VINYL CHLORIDE
MW-020
MW-011
1/99
0.3 U
0.9 U
0.5 U
0.3 U
MW-015
2/18 3/19 03/20 02/21
0.22 U 0.38 U 0.50 U 0.38 U
0.36 U 0.36 U 0.50 U 0.36 U
0.36 U 0.27 U 0.50 U 0.27 U
0.36 U 0.39 U 0.50 U 0.39 U
MW-012
2/18 3/19 03/20 02/21
3.8 3.3 0.38 U 5.0
0.72 U 0.36 U 0.36 U 0.36 U
0.72 U 0.27 U 0.27 U 0.27 U
0.72 U 0.39 U 0.39 U 0.39 U
MW-005
2/18 3/19 03/20 02/21
8,200 4,800 3,990 3,260 180 142 169 145 I 220 191 373 1,490
36 U 0.39 U 0.50 U 11.0
MW-014
2/18 3/19 03/20 02/21
0.23 I 0.38 U 0.38 U 0.38 U
0.36 U 0.36 U 0.36 U 0.36 U
0.36 U 0.27 U 0.27 U 0.27 U
0.36 U 0.39 U 0.39 U 0.39 U
MW-004
2/18 3/19 03/20 02/21
7,900 9,040 8,580 8,780 36 U 19.0 19.3 17.0 36 U 27.7 7.5 7.2 36 U 1.40 0.39 U 0.39 U
MW-002
2/18 3/19 03/20 02/21
28 17.0 5.2 4.0
2.2 1.2 0.50 U 1.3
8.4 1.5 0.50 U 0.23 U
0.36 U 0.39 U 0.50 U 0.44 I
ESTIMATED EXTENT OF VOLATILE ORGANIC
COMPOUNDS (VOCs) EXCEEDING GCTLs
ESTIMATED EXTENT OF VOLATILE ORGANIC
COMPOUNDS EXCEEDING NADCs
APPROXIMATE PROPERTY
BOUNDARY
MW-026
2/18 3/19 03/20 02/21 26 2.4 3.9 0.59 I
1.5 0.36 U 0.50 U 0.36 U
0.36 U 1.3 1.8 1.7
0.36 U 0.39 U 0.50 U 0.39 U
MW-009 ABANDONED WELL LOCATION
GCTLs NADCs
FORMER
SHELL
STATION
BP
STATION
ALLEY
MERRIL ROAD
R
ED
O
AK
D R
IV
E
BL
U
EB
ER
R Y
LA
N
E
O
AK
S U
M M
IT
D
R
IV
E
C
ES
ER
Y
BO
U
LE
VA
R D
OFFICE
KITCHEN
W O
M
EN
'S R
M
M
EN
'S R
M
MW-001
MW-002
MW-021
MW-023
MW-022
MW-018
MW-017
MW-019 MW-025
MW-020MW-003
MW-004
MW-012
MW-005
MW-006
MW-013
MW-014
MW-008
MW-007
MW-015
MW-016
MW-009
MW-024
MW-010
MW-011
MW-026
MW-027
MW-028
MW-029
MW-030
TRAILER
FORMER DRYCLEANER LOCATION
CURRENT BUILD-OUT
in
FDEP-DC019
Control No.
FDEPDC019-ZA008
FIGURE
2021-03-11
BCL
RFM
RFM
JCB
LAKE LUCINA
JACKSONVILLE, DUVAL COUNTY, FLORIDA
FL. DEPT. OF ENVIRONMENTAL PROTECTION
GROUNDWATER CHARACTERIZATION IN THE DEEP ZONE OF
THE SURFICIAL AQUIFER
TITLE
PROJECT NO. REV.
PROJECTCLIENT
CONSULTANT
PREPARED
DESIGNED
REVIEWED
APPROVED
YYYY-MM-DD
IF
T
H
IS
M
EA
SU
R
EM
EN
T D
O
ES
N O
T M
AT
C
H W
H
AT
IS
S
H O
W N
, T H
E
SH
EE
T
SI
ZE
H
AS
B
EE
N M
O D
IF
IE
D F
R O
M : A
N
SI
B
Pa th
\g ol de r.g ds
\c om pl ex da ta
\O ffi ce \J ac ks on vi lle \d ra fti ng \F ile \F
D
EP
\F D
EP
-D
C \D
C N o
La ke L uc in a\
ZA
A nn ua l G W
M R
\A ct iv e
D ra w in gs
Fi le N am e:
F D
EP
D
C
9-
ZA
8.
dw
VALUE SHOWN IS THE METHOD DETECTION LIMIT.
3. I - THE REPORTED VALUE IS BETWEEN THE LABORATORY METHOD DETECTION
LIMIT AND THE LABORATORY PRACTICAL QUANTITATION LIMIT.
4. GCTL - GROUNDWATER CLEANUP TARGET LEVEL PER CHAPTER 62-777, TABLE I,
OF THE FLORIDA ADMINISTRATIVE CODE (FAC).
5. NADC - NATURAL ATTENUATION DEFAULT CONCENTRATION PER CHAPTER
62-777, TABLE V, OF THE FAC.
6. BOLD FONT AND YELLOW SHADED CELL INDICATES AN EXCEEDANCE OF THE
APPLICABLE GCTL.
7. BOLD FONT AND BLUE SHADED CELL INDICATES AN EXCEEDANCE OF THE
APPLICABLE NADC.
8. ISOCONCENTRATION CONTOURS DASHED WHERE INFERRED.
SCALE
0 60 120
FEET
REFERENCE(S)
1. AERIAL IMAGE TAKEN FROM FDEP BUREAU OF SURVEY AND MAPPING (LAND
BOUNDARY INFORMATION SYSTEM 2013).
MONITORING WELL LOCATION
MW-008
7/14 10/14
3 300 3 300
70 700 1 100
WELL I.D.
DATE SAMPLED
TETRACHLOROETHENE (PCE)
TRICHLOROETHENE (TCE)
cis-1,2-DICHLOROETHENE (DCE)
VINYL CHLORIDE
MW-020
ESTIMATED EXTENT OF VOLATILE ORGANIC
COMPOUNDS (VOCs) EXCEEDING GCTLs
ESTIMATED EXTENT OF VOLATILE ORGANIC
COMPOUNDS EXCEEDING NADCs
MW-016
2/18 3/19 03/20 02/21 16 5.2 6.6 4.5
1.1 0.52 I 0.50 U 0.77 I
6.1 4.8 3.0 5.2
0.36 U 0.39 U 0.50 U 0.39 U
MW-013
2/18 3/19 03/20 02/21
0.74 I 0.65 I 0.38 U 1.1
0.36 U 0.36 U 0.36 U 0.36 U
0.82 I 1.2 1.6 4.5
0.36 U 0.39 U 0.39 U 0.39 U
MW-006
2/18 3/19 03/20 02/21
1,200 589 515 369 50 I 45.3 38.9 41.2 36 U 11.6 10.4 10.4 36 U 0.39 U 0.50 U 0.39 U
MW-007
2/18 3/19 03/20 02/21
4,000 3,680 395 640 130 107 20.8 29.9 210 161 50.2 48.8 36 U 4.1 1.2 1.8
APPROXIMATE PROPERTY
BOUNDARY
GCTLs NADCs
ABANDONED WELL LOCATIONMW-009
From: Fred Portofe To: Mongillo, Ralph Cc: Madison Rogers; Roger Pragle; Crews, Matt Subject: RE: Investigative Derived Waste Drum Costs for Transportation and Disposal at a Regulated Facility Date: Wednesday, March 9, 2022 9:33:38 AM Attachments: F0152F28A2B5418EBC7A4FD870EC8D28.png
AD282F6C3391468088CDA42829B8E703.png A719914B10184314957B0CA910CA8D14.png F1DF3C4322764E8A9076F1ADFF76864A.png 3409DF389C3B4156BA232DDC85C60E09.png
EXTERNAL EMAIL
EXTERNAL EMAIL - We could not verify the authenticity of this message. Please be cautious when clicking on links or opening attachments.
Ralph
We are not going to provide annual Pricing for the Statewide Contract . After reviewing the scope with my partners and the variability with respect to disposal costing and ever changing fuel costs, we feel we can not bid this work given the current uncertainty in the market. We would be please to bid this work on a casa by case basis.
Fred G. Portofe, PG President of Environmental Services (Professional Geologist in FL, GA, AL, MS, TX, SC, NC, TN, IN, LA, WI and AK) M & D Industrial Services, LLC 5896 Azalea Street Port Orange, Florida 32127 Email: Fportofe@mdindustrialservices.com Website: mdindustrialservices.com Cell: 813-951-1012 Emergencies: 888-307-2790
Sent from Mail for Windows
From: Mongillo, Ralph Sent: Tuesday, March 8, 2022 12:46 PM To: Fred Portofe Cc: Madison Rogers; Roger Pragle; Eddy Mendoza; Crews, Matt mailto:fportofe@mdindustrialservices.com mailto:ralph.mongillo@wsp.com mailto:mrogers@mdindustrialservices.com mailto:rpragle@mdindustrialservices.com mailto:matt.crews@wsp.com mailto:Fportofe@mdindustrialservices.com https://nam10.safelinks.protection.outlook.com/?url=http%3A%2F%2Fmdindustrialservices.com%2F&data=04%7C01%7Cmculbreth%40ectinc.com%7Cbfdc4a6d2ce945e1eaf008d9dcf8eabf%7C911eb1cc54d34d8ca5773bf3ccc8105c%7C0%7C0%7C637783784008834159%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C2000&sdata=ntkZP1OGe7McYRA722JXtcGwkbgN9EEhQtSgBSKqC3E%3D&reserved=0 https://go.microsoft.com/fwlink/?LinkId=550986 mailto:Ralph_Mongillo@golder.com mailto:fportofe@mdindustrialservices.com mailto:mrogers@mdindustrialservices.com mailto:rpragle@mdindustrialservices.com mailto:emendoza@mdindustrialservices.com mailto:Matt_Crews@golder.com
File details come from the government source that posted it. Updated .