CN-370000-HW685-DC010A.pdf

PDF 2 MB Posted

Attached to
Master Agreement FL|HW685|184b9800bda47b032a54413957b4b38d
Contract number
HW685
Issued by
Florida

About this file

This is a Task Assignment (TA) issued by the Florida Department of Environmental Protection (FDEP) to Golder Associates USA Inc. for groundwater monitoring activities at the Former Swift Cleaners site located at 2754 Cesery Boulevard, Jacksonville, Duval County, Florida (ERIC_4553). The Task Assignment, numbered DC010A under master Contract HW685, is effective through August 31, 2022, and authorizes the contractor to conduct annual groundwater monitoring in accordance with the March 29, 2022 Scope of Work, Cost Estimate, and Bid Documentation.

The contract authorizes groundwater monitoring from 14 monitoring wells across multiple aquifer intervals, with sample analysis for chlorinated volatile organic compounds using EPA Method 8260B. The work is divided into three subtasks: Subtask 1 covers project management at $992.11; Subtask 2 covers annual groundwater monitoring and investigation-derived waste disposal at $7,042.47; and Subtask 3 covers reporting and GIS updates at $3,468.11, for a total contract value of $11,502.69. The scope includes 68 labor hours allocated across various staff levels with an overhead rate of 172.50%, field expenses totaling $1,177.00, laboratory analytical costs of $1,352.00, and investigation-derived waste disposal at $100.00 per drum. Deliverables are due in phases: field documentation by May 31, 2022, and the final annual groundwater monitoring report by June 30, 2022, with project completion by August 31, 2022.

View the file

Other files

File Type Posted
CN-370000-HW685-BF01A.pdf PDF
CN-370000-HW685-BF01CCO1.pdf PDF
CN-370000-HW685-BF02A.pdf PDF
CN-370000-HW685-BF05A.pdf PDF
CN-370000-HW685-BF05ACO1.pdf PDF
CN-370000-HW685-BF1BCO1.pdf PDF
CN-370000-HW685-BIL02C.pdf PDF
CN-370000-HW685-BIL1ACO4.pdf PDF
CN-370000-HW685-BIL2CCO1.pdf PDF
CN-370000-HW685-BIL3ACO1.pdf PDF
CN-370000-HW685-CSS01.pdf PDF
CN-370000-HW685-CSS2ACO2.pdf PDF
CN-370000-HW685-DC001C.pdf PDF
CN-370000-HW685-DC001E.pdf PDF
CN-370000-HW685-DC002B.pdf PDF
CN-370000-HW685-DC002C.pdf PDF
CN-370000-HW685-DC002E.pdf PDF
CN-370000-HW685-DC003C.pdf PDF
CN-370000-HW685-DC004A.pdf PDF
CN-370000-HW685-DC007A.pdf PDF
CN-370000-HW685-DC007B.pdf PDF
CN-370000-HW685-DC008B.pdf PDF
CN-370000-HW685-DC008D.pdf PDF
CN-370000-HW685-DC009A.pdf PDF
CN-370000-HW685-DC009D.pdf PDF
CN-370000-HW685-DC009E.pdf PDF
CN-370000-HW685-DC010C.pdf PDF
CN-370000-HW685-DC012A.pdf PDF
CN-370000-HW685-DC012D.pdf PDF
CN-370000-HW685-DC014B.pdf PDF
CN-370000-HW685-DC016D.pdf PDF
CN-370000-HW685-DC017A.pdf PDF
CN-370000-HW685-DC017B.pdf PDF
CN-370000-HW685-DC018B.pdf PDF
CN-370000-HW685-DC019A.pdf PDF
CN-370000-HW685-DC019C.pdf PDF
CN-370000-HW685-DC01ACO1.pdf PDF
CN-370000-HW685-DC01ECO1.pdf PDF
CN-370000-HW685-DC021A.pdf PDF
CN-370000-HW685-DC021B.pdf PDF
CN-370000-HW685-DC021C.pdf PDF
CN-370000-HW685-DC021E.pdf PDF
CN-370000-HW685-DC022C.pdf PDF
CN-370000-HW685-DC023A.pdf PDF
CN-370000-HW685-DC023D.pdf PDF
CN-370000-HW685-DC024C.pdf PDF
CN-370000-HW685-DC025A.pdf PDF
CN-370000-HW685-DC027D.pdf PDF
CN-370000-HW685-DC028A.pdf PDF
CN-370000-HW685-DC028D.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Funding Information:

Org. Code E.O. Object Code Budget Entity Appropriation

Category Grant # Project # Year Amount

☐ Additional Funding Information attached on separate page.

Rev. 8/26/2020

STATE OF FLORIDA

DEPARTMENT OF ENVIRONMENTAL PROTECTION

Task Assignment This Task Assignment (TA) is entered into between the Parties named below, pursuant to Contract Number: .

1. TA Number: TA Completion Date:

TA Description:

2. Parties State of Florida Department of Environmental Protection

(Department)

Department Project Manager: Department Project Manager Phone:

Contractor Name: (Contractor ) ntractor’st ’s Project Manager: ontractor’s t’s Project Manager Phone:

3. Project Number:

(If different from TA Number)

Project Location(s):

Project Name:

4. As consideration for the services rendered by Contractor under the terms of this TA, the Department shall pay the Contractor on the following bases, up to the Total TA Value as indicated below:

☐ Fixed Price:

☐ Fixed Unit Rate: (Extended Price)

☐ Cost Reimbursement:

Total TA Value:

5. The Parties agree to comply with the terms and conditions of the underlying the Contract, and the following attachments which are hereby incorporated by reference:

Attachment 1:

☐ Additional Attachments (if necessary):

IN WITNESS WHEREOF, this TA shall be effective on the last date signed below.

State of Florida Department of Environmental Protection CONTRACTOR Department Name:

Title:

Secretary or Designee

(Authorized Signature) (Authorized Signature) Date:

☐ Additional signatures attached on separate page.

HW685

DC010A Completion August 31, 2022

This Task Assignment authorizes Golder to conduct groundwater monitoring activities in accordance with the March 29, 2022, Scope of Work, Cost Estimate, and Bid Documentation.

Ben Grubbs 850-245-8992 Contractor Contractor

Contractor Contractor

Contractor Contractor

Contractor

Golder Associates USA Inc.

Golder Associates USA Inc.

Matt Crews 904-363-3430

ERIC_4553

2754 Cesery Boulevard, Jacksonville, Duval County

Swift Cleaners Inc (Cesery)

✔ $ 11,502.69

$ 11,502.69

Scope of Work

Donald Miller

Principal

Donald Miller Digitally signed by Donald Miller Date: 2022.04.06 13:03:02 -04'00'

William E. Burns, Jr.

William E. Burns, Jr. Digitally signed by William E. Burns, Jr.

Date: 2022.04.06 11:25:26 -04'00'

N/A

Task Assignment Notification/Change Order Deliverables and Invoice Schedule Attachment

WCP TAFORM 04-2017

Contract Number:

Task Assignment #:

Deliverables:

Deliverable Deliverable Due Date

Invoice Schedule:

Requirements for Invoice Submittal Amount to be Invoiced

TOTAL COST

Subtask 2: Groundwater Monitoring Field Documentation and Laboratory Report;

IDW Disposal Documentation 05/31/2022

Subtasks 1 & 3: Annual Groundwater Monitoring Report; ADaPT/GIS Update; Project Management 06/30/2022

Subtask 2: Submittal and FDEP approval of the Groundwater Monitoring Field Documentation and Laboratory Report; IDW Disposal Documentation $ 7,042.47

Subtasks 1 & 3: Submittal and FDEP approval of the Annual Groundwater Monitoring Report; ADaPT/GIS Update; Project Management $ 4,460.22

$ 11,502.69

HW685

DC010A

Printed on recycled paper.

FLORIDA DEPARTMENT OF

Environmental Protection

Bob Martinez Center

2600 Blair Stone Road Tallahassee, FL 32399-2400

Ron DeSantis Governor

Jeanette Nuñez

Lt. Governor

Shawn Hamilton Secretary

To: HW685 Contract Negotiation File Swift Cleaners Inc (Cesery) Jacksonville, Duval County

ERIC_4553

From: Ben Grubbs, Project Manager Date: April 5, 2022 Subject: Negotiation Summary

HW685 DC010A

This Task Assignment authorizes Golder to conduct groundwater monitoring activities in accordance with the March 29, 2022, Scope of Work, Cost Estimate, and Bid Documentation.

Subtask 1: Project Management An automatic calculation based upon total direct labor hours determines the labor hours within this subtask.

Subtask 2: Annual Groundwater Monitoring Golder will collect groundwater samples from monitoring wells MW049, MW005, MW013, MW023, MW029, MW006, MW018, MW024, MW030, MW037, MW048, MW050, MW031, and MW051. Prior to sampling, depth-to-water will be measured. The wells will then be purged, and field parameters will be recorded. The groundwater samples will be collected using low flow sampling methods and analyzed for chlorinated volatile organic compounds (VOCs).

Investigation-derived waste (IDW) will be temporarily stored in a 55-gallon drum. Golder requested bids for IDW drum treatment and disposal from Clark, Erwin, Whatever Waste, and M & D Industrial Services. Erwin was selected as the lowest responsive and responsible bidder.

Subtask 3: Reporting Golder will submit the Annual Groundwater Monitoring Report and ADaPT and GIS deliverables to FDEP.

Golder and the FDEP confirmed on March 29, 2022, that an Access Agreement with the current real property owner of the Swift Cleaners Inc (Cesery) (ERIC_4553) site has been executed.

The FDEP Project Manager agrees to the scope of work and final cost associated with this Task Assignment. The final cost for this Task Assignment is $11,502.69 with 68 labor hours.

Golder may invoice following the schedule established in the Deliverables and Invoice Schedule Attachment, which accompanies the Task Assignment Notification Form.

FDEP COST ESTI MATEContractor: Golder Associates USA Inc.

Date: 3/29/2022

Task #: DC010A SubTask 1 Project Management SubTask 6

Site: SubTask 2 Annual GW Monitoring SubTask 7

Activity/Phase: Assessment SubTask 3 Reporting SubTask 8

Project Manager: Ben Grubbs SubTask 4 SubTask 9

SubTask 5 SubTask 10

Totals 1 2 3 4 5 6 7 8 9 10 Labor Rate Category

$51.23 Project Manager (RFM) 7 6.5 $0.00 Program Leader - X-14 0 0 0 0 0 0 0 0 0 0

$61.56 Practice Leader - X-13 (JB) 3 0 3 0 0 0 0 0 0 0 $0.00 Senior Consultant - X-12 0 0 0 0 0 0 0 0 0 0

$51.23 Senior Sci/Eng - X-11 (RFM) 19 7 12 0 0 0 0 0 0 0 $45.42 Senior Project Sci/Eng - P-10 (BL) 4 0 4 0 0 0 0 0 0 0 $44.15 Project Sci/Eng - P-10 (JT) 3 0 2.5 0 0 0 0 0 0 0 $33.32 Staff Sci/Eng - P-8 (JS) 16 16 0 0 0 0 0 0 0 0 $33.15 Staff Sci/Eng - P-8 (KF) 15 15 0 0 0 0 0 0 0 0 $32.75 Staff Sci/Eng - P-8 (AS) 2 0 2 0 0 0 0 0 0 0

$0.00 Sci/Eng/Admin - P-7 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0

$0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0

Total Hours 68 6.5 38.0 23.5 0 0 0 0 0 0 0

Direct Labor $2,876.96 $330.98 $1,388.98 $1,157.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00

Overhead 172.50% $4,962.76 $570.94 $2,395.99 $1,995.83 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Gen & Admin 0.00% $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Fringe 0.00% $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Total Labor $7,839.72 $901.92 $3,784.97 $3,152.83 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00

Former Swift Cesery Drycleaners

REV: 02/03 CEF GOLDER Page 1

FDEP COST ESTI MATEContractor: Golder Associates USA Inc.

Date: 3/29/2022

Task #: DC010A SubTask 1 Project Management SubTask 6

Site: SubTask 2 Annual GW Monitoring SubTask 7

Activity/Phase: Assessment SubTask 3 Reporting SubTask 8

Project Manager: Ben Grubbs SubTask 4 SubTask 9

SubTask 5 SubTask 10

Totals 1 2 3 4 5 6 7 8 9 10

Former Swift Cesery Drycleaners

Travel Vehicle Rental $240.00 $240.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Mileage Costs $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Air Fare $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Per diem + Hotel $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Total Travel $240.00 $240.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00

Subcontractor (Equipment Procurement) $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00

$0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00

Subcontractor Subtotal $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Procurement Fee $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Total Subcontractor Cost $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00

Subcontractor (Services Procurement) Drilling (Conventional) $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Drilling (Non-conventional) $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Mobile Laboratory $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Surveying $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00

IDW $100.00 $100.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00

Utilities $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Utility Location $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00

$0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00

Subcontractor Subtotal $100.00 $100.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Handling Fee $10.00 $10.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Total Subcontractor Cost $110.00 $110.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00

Laboratory Analytical Costs $1,132.00 $1,132.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Fast Turnaround Charges $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Sample Shipping $220.00 $220.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Total Laboratory $1,352.00 $1,352.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00

Field Expenses Personal Protection $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Expendables $80.00 $80.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Equipment (Drilling related) $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Equipment (Analytical related) $997.00 $997.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Equipment (IDW related) $100.00 $100.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Equipment (Other) $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Total Field Expenses $1,177.00 $1,177.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00

Subtotal $10,718.72 $901.92 $6,663.97 $3,152.83 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Completion Fee $783.97 $90.19 $378.50 $315.28 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00

Total Estimated Cost $11,502.69 $992.11 $7,042.47 $3,468.11 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00

REV: 02/03 CEF GOLDER Page 2

LEVEL OF EFFORT/EXPENSE WORKSHEET

SITE : Former Swift Cesery Drycleaners SUBTASK 2: Annual GW Monitoring

DATE: 3/29/2022

LABOR CATEGORY *PROVIDE TIME REQUIRED FOR EACH PERSON

STAFF-TITLE WORK DESCRIPTION HOURS

Senior Sci/Eng (R Mongillo) 7

Staff Sci/Eng (J. Spengler) 16

Project Sci/Eng (K. Fraley) 15

TOTAL LABOR 38

VEHICLE TYPE RATE UNIT USEAGE

Truck (GW sampling $120.00 Per Day 2 $240.00

TOTAL VEHICLE $240.00

PER DIEM STAFF RATE UNIT USEAGE

TOTAL PER DIEM $0.00

SUBCONTRACTOR COSTS

NAME PURPOSE COST

Erwin IDW T&D - Liquids $100.00 Per Drum 1 $100.00

TOTAL $100.00

LABORATORY COSTS

PARAMETER RATE # SAMPLES #QAQC

Chlorinated VOCs - EPA Method 8260B Total VOHs EPA Method 8260B $73.00 14 $1,022.00 Total VOCs (IDW) EPA Method 8260B $110.00 1 $110.00 Sample Shipping Small $110.00 2 $220.00

TOTAL LAB $1,352.00

EQUIPMENT ITEM RATE COSTING UNIT USEAGE TOTALS

Miscellaneous Expendables $40.00 Per Day 2 $80.00 Shallow Groundwater Sampling Kit $290.00 Per Day 2 $580.00 Tubing, Poly HDPE $0.30 Per Foot 1250 $375.00 Tubing, Silicon 3/16 x 3/8 $3.00 Per foot 14 $42.00 Drum, 55-gallon $100.00 Per Drum 1 $100.00

TOTAL EQUIPMENT $1,177.00

Mobilize and collect water levels and samples from 14 monitoring wells associated with the annual groundwater sampling event: MW049 in the shallow zone of the surficial aquifer;

MW005, MW013, MW023, and MW029 in the intermediate zone of the surficial aquifer; MW006, MW018, MW024, MW030, MW037, MW048, and MW050 in the deep zone of the surficial aquifer; and MW031 and MW051 in the rock aquifer interval. Field event preparation (1 hour).

Locate wells for water level gauging (1 hour). Water levels, instrument calibration, and sampling (12 hours). Round trip travel 1 hour per day two trips (2 hours).

Communication with RPO (verification of property ownership) and offsite property owners for site access (2 hrs), prepare and submit field notes, sample forms, and laboratory report in an email deliverable to the DEP and contact Toro Jax Property LLC for site access agreement signature (3 hours), and characterization and waste profile for transportation and disposal of IDW drum(s) (2 hours).

Mobilize and collect water levels and samples from 14 monitoring wells associated with the annual groundwater sampling event: MW049 in the shallow zone of the surficial aquifer;

MW005, MW013, MW023, and MW029 in the intermediate zone of the surficial aquifer; MW006, MW018, MW024, MW030, MW037, MW048, and MW050 in the deep zone of the surficial aquifer; and MW031 and MW051 in the rock aquifer interval. Locate wells for water level gauging (1 hour). Water levels, instrument calibration, and sampling (12 hours). Round trip travel 1 hour per day two trips (2 hours).

FINAL --7/24/96

LEVEL OF EFFORT/EXPENSE WORKSHEET

SITE : Former Swift Cesery Drycleaners SUBTASK 3: Reporting

DATE: 3/29/2022

LABOR CATEGORY *PROVIDE TIME REQUIRED FOR EACH PERSON

STAFF-TITLE WORK DESCRIPTION HOURS

Practice Leader (J. Brown) 3 Senior Sci/Eng (R Mongillo) 12

Senior Project Sci/Eng (J. Thomas) 2.5

Senior Project Sci/Eng (B. Lucero) 4 Staff Sci/Eng (A. Strayer) 2

TOTAL LABOR 23.5

VEHICLE TYPE RATE UNIT USEAGE

TOTAL VEHICLE $0.00

PER DIEM STAFF RATE UNIT USEAGE

TOTAL PER DIEM $0.00

SUBCONTRACTOR COSTS

NAME PURPOSE COST

TOTAL $0.00

LABORATORY COSTS

PARAMETER RATE # SAMPLES #QAQC

TOTAL LAB $0.00

EQUIPMENT ITEM RATE COSTING UNIT USEAGE TOTALS

TOTAL EQUIPMENT $0.00

Reporting: Updating tables, document production, binding and shipping. Create pdf for OCULUS.

Develop conclusions and recommendations and prepare final Annual Monitoring Report.

Data entry, prepare tables and figures, and draft Annual Monitoring Report Update FDEP GIS Tables, run data checker, create and edit error report, and annotate error report (14 data points x 8 min/point = 112 minutes). Submit FDEPGIS tables; submit ADaPT deliverable (0.5) CADD Update Figures (two groundwater flow and five CVOC detections) for the report.

FINAL --7/24/96

Golder Associates USA Inc.

9428 Baymeadows Road, Suite 400, Jacksonville, Florida, USA 32256

T: +1 904 363-3430 F: +1 904 363-3445 golder.com

March 29, 2022 Proposal No. 202208346

Mr. Ben Grubbs Florida Department of Environmental Protection Division of Waste Management Drycleaning Solvent Cleanup Program 2600 Blair Stone Road, MS 4520 Tallahassee, FL 32399-2400

RE: COST PROPOSAL FOR THE FORMER SWIFT CLEANERS

ANNUAL GROUNDWATER MONITORING

2754 CESERY BOULEVARD

JACKSONVILLE, DUVAL COUNTY, FLORIDA

DEP FACILITY ID NUMBER: ERIC_4553

PROPOSED TASK ASSIGNMENT: HW685_DC010A

Dear Mr. Grubbs:

Golder Associates USA Inc. (Golder) is pleased to provide the Florida Department of Environmental Protection (DEP) with this cost proposal for annual groundwater monitoring at the above-referenced site. This proposal includes a description of the proposed scope of services, level of effort sheets for each subtask, and a cost estimate form that summarizes the costs of the proposed services. The scope of work is based on the recommendations accepted by the DEP in the May 24, 2021 electronic mail correspondence to Golder. The proposed scope of services is described below.

SUBTASK 1 – PROJECT MANAGEMENT

To facilitate project quality and satisfactory completion of the proposed scope of work, all aspects of this project will be overseen by an experienced project manager. The project manager will be responsible for the schedule, budget, invoicing, project activities, and communications with DEP and the field team. Project management will include coordination of field activities; resource allocation to confirm the work is conducted by qualified professionals in accordance with the project schedule; cost control and tracking of the budget status; and submittal of project invoices in accordance with DEP Drycleaning Solvent Cleanup Program requirements. The project manager will oversee the work so that it is conducted in a manner that is consistent with the requirements of the DEP-approved task assignment.

SUBTASK 2 – ANNUAL GROUNDWATER MONITORING AND IDW TREATMENT

Golder will mobilize to the site and collect groundwater samples from the following 14 monitoring wells during the next annual groundwater sampling event: MW049 in the shallow zone of the surficial aquifer; MW005, MW013, MW023, and MW029 in the intermediate zone of the surficial aquifer; MW006, MW018, MW024, MW030, MW037, Mr. Ben Grubbs Proposal No. 202208346

Florida Department of Environmental Protection March 29, 2022

MW048, and MW050 in the deep zone of the surficial aquifer; and MW031 and MW051 in the rock aquifer interval.

Monitoring wells MW050 (deep interval) and MW051 (rock aquifer interval) will be used as temporary point of compliance wells for their respective aquifer intervals. Figures 6 through 10 from the previous annual monitoring report, which show volatile organic compound (VOC) results for the surficial and rock aquifers, are attached.

Prior to groundwater sampling, depth-to-water measurements will be collected using an electronic water level indicator to determine groundwater depth. During the sampling event, the locks and well caps will be inspected for damage or degradation and repaired or replaced, as necessary.

Groundwater samples will be collected from the wells in accordance with DEP Standard Operating Procedures (SOPs) for Field Activities (DEP SOP-001/01). Prior to collecting the groundwater sample, each well will be purged and field parameters including temperature, pH, specific conductance, dissolved oxygen, turbidity, and oxidation reduction potential will be monitored. Purge volumes and field parameters will be recorded on field data sheets, and the field monitoring equipment will be calibrated in accordance with the manufacturer’s recommended procedures.

Groundwater samples will be collected using low flow sampling methods. The groundwater samples will be placed in laboratory-supplied containers, labeled with a unique identification number attached to the outside of the sample container, preserved on ice in a laboratory-provided cooler at a maximum temperature of four degrees Celsius, and delivered to a Florida Department of Health and National Environmental Laboratory Accreditation Program-certified fixed-base laboratory along with the completed chain-of-custody documentation to be analyzed for chlorinated VOCs using EPA Method 8260B. Upon receipt of the laboratory analytical results, Golder will evaluate the constituent concentrations to determine if off-site notification is required.

Golder will temporarily store the investigation derived waste (IDW) purge water generated from the groundwater sampling event in a 55-gallon steel drum(s). A waste characterization sample will be collected from the IDW drum(s) for analysis of total VOCs using EPA Method 8260. If the waste characterization sample is acceptable to the disposal subcontractor, the IDW drum(s) will be picked up and transported to a facility for proper disposal. A non-hazardous waste manifest will be provided by the disposal subcontractor upon delivery to the disposal facility.

Upon completion of Subtask 2, an e-mail deliverable will be submitted and include copies of the field data sheets, equipment calibration forms, field notes, laboratory analytical report, and laboratory chain-of-custody documentation.

SUBTASK 3 – REPORTING

The annual groundwater monitoring report will include a description of the sampling procedures, evaluation of the analytical results, comparison of current to historical data, tabulated summary of the current and historical analytical data, a site map showing the groundwater analytical results, water level elevation information in tables and figures, laboratory analytical data, conclusions, and recommendations. Golder will also update the DEP GIS tables with the new water level data, field parameter measurements, and VOC data; run the DEP data checker on the completed tables; and submit the updated tables and error reports under this subtask. Additionally, Golder will forward the Automated Data Processing Tool (ADaPT) data deliverables for the groundwater sampling event provided by the laboratory.

HEALTH AND SAFETY

Golder will update the existing site-specific Health and Safety Plan for the field work. The work will be completed in accordance with Golder’s safety policies and procedures. At a minimum, Golder will wear safety glasses, high visibility safety vests, and steel-toed boots. A safety job briefing will be conducted prior to the start of work activities, and anytime the scope of work or site conditions change.

COST AND SCHEDULE

The estimated cost to complete the proposed scope of work is $11,502.69. Golder anticipates the monitoring event will take place in late April or middle May 2022. The LOE/CEF sheets are included in Attachment A. Disposal subcontractor IDW quotes are included in Attachment B. The following table summarizes the proposed costs and deliverable schedule.

Task Proposed Cost Proposed Schedule/Deliverables

Subtask 1 – Project Management $ 992.11 July 30, 2022

Subtask 2 – Annual Groundwater Monitoring

$ 7,042.47 May 30, 2022 (Field documentation and laboratory analytical report via E-mail)

Subtask 3 – Reporting $ 3,468.11 June 30, 2022 (Annual Groundwater Monitoring Report)

Total/Completion Date $11,502.69 August 31, 2022

Please be aware that Golder has been acquired by and is now a Member of the WSP family of companies. Golder remains as a legal entity and is the proposed contracting entity for this proposal. We are in the process of integrating the resources of our companies. Correspondence for this proposal should continue to be addressed to the undersigned.

Golder appreciates the opportunity to provide services under the Drycleaning Solvent Cleanup Program. Should you require additional information or clarifications, please contact us at (904) 363-3430.

Sincerely, Golder Associates USA Inc.

Ralph F. Mongillo, Jr., PG Jesse C. Brown, PE Lead Consultant / Senior Geologist Director, Environmental Engineer

RFM/JCB/as

Attachments: Figure 6 – Groundwater Characterization in the Shallow Zone of the Surficial Aquifer (+25 to +40 feet MSL) Figure 7 – Groundwater Characterization in the Intermediate Zone of the Surficial Aquifer (+10 to +25 feet MSL) Figure 8 – Groundwater Characterization in the Deep Zone of the Surficial Aquifer (-5 to +10 feet MSL) Figure 9 – Groundwater Characterization in the Rock Zone of the Surficial Aquifer (-20 to -5 feet MSL) Figure 10 – Groundwater Characterization TPOC Wells

Attachment A Level of Effort Sheets and Cost Estimate Form Attachment B Subcontractor Quotes

G:\Projects\DEP-Drycleaning\Projects\Jax\Swift Cesery Blvd - HW685\Proposal\HW685 Swift Cesery Annual GW Monitoring proposal - ERIC_4553.docx

King Burger

Salon Hair

Cleaners Swift

Center Medical Animal

TR

O

LL

IE

L

AN

E

MERRILL ROAD

C

ES

ER

Y

BO

U

LE

VA

R D

GREEN PALM LANE

ST

AR

D U

ST

C

O U

R T

Lake Lucina Center

Po ol

Burger King

MW-004MW-049

MW-001

MW-032

MW-035

MW-028

MW-010

MW-007

MW-034

MW-012

cis-1,2-DICHLOROETHENE (cis-1,2-DCE)

TRICHLOROETHENE (TCE)

TETRACHLOROETHENE (PCE)

MW0XX

JAN 2013 JAN 2013

3 300 3 300

70 700 1 100

MONITORING WELL I.D.

SAMPLE DATE

VINYL CHLORIDE (VC)

GROUNDWATER CLEANUP TARGET

LEVELS (GCTLs)

NATURAL ATTENUATION DEFAULT

CONCENTRATIONS (NADCs)

MONITORING WELL LOCATIONS

PROPERTY LINE

MW-049

MAR 2017 MAR 2018 MAR 2019 MAR 2020 FEB 2021

7.1 0.22 U 1.1 1.1 0.35 U

0.61 U 0.36 U 0.36 U 0.36 U 0.33 U

0.65 U 0.36 U 0.36 U 0.36 U 0.32 U

0.71 U 0.36 U 0.36 U 0.36 U 0.30 U

MW-032

SEP 2004 MAY 2006 DEC 2007 APR 2009

18 7.7 5.1 0.91 I

0.17 U 0.11 U 0.13 U 0.069 U

0.090 U 0.18 U 0.18 U 0.17 U

0.25 U 0.29 U 0.058 U 0.16 U

MW-001

SEP 2004 MAY 2006 DEC 2007 DEC 2007 (DUP)

8.8 11 1.4 1.4

0.50 I 0.58 I 0.22 IV 0.27 IV

0.090 U 0.18 U 0.18 U 0.18 U

0.25 U 0.29 U 0.058 U 0.058 U

MW-004

SEP 2004 MAY 2006 DEC 2007

99 46 0.55 I

10 5.5 0.15 IV

0.090 U 0.18 U 0.18 U

0.25 U 0.29 U 0.29 U

MW-007

SEP 2004 MAY 2006 DEC 2007

2.7 3.1* 1.9

0.24 I 0.30 I 0.31 I

0.090 U 0.18 U 0.18 U

0.25 U 0.29 U 0.058 U

MW-028

SEP 2004 MAY 2006 DEC 2007

0.17 U 2.7 0.30 I

0.17 U 0.14 I 0.61 IV

0.090 U 0.18 U 0.18 U

0.25 U 0.29 U 0.058 U

MW-012

SEP 2004 MAY 2006

1.5 1.2

0.17 U 0.11 U

0.090 U 0.18 U

0.25 U 0.29 U

MW-010

APR 1997

1.0 U

1.0 U

1.0 U

1.0 U

in

FDEP-DC018M

Control No.

FDEP-DC018-J006

FIGURE

2021-03-10

BCL

RFM

RFM

JCB

2021 GROUNDWATER MONITORING REPORT

SWIFT CLEANERS

JACKSONVILLE, DUVAL COUNTY, FLORIDA

FL. DEPT. OF ENVIRONMENTAL PROTECTION

GROUNDWATER CHARACTERIZATION

SHALLOW ZONE SURFICIAL AQUIFER

(+25 TO +40 FEET MSL)

TITLE

PROJECT NO. REV.

PROJECT

CLIENT

CONSULTANT

PREPARED

DESIGNED

REVIEWED

APPROVED

YYYY-MM-DD

IF

T

H

IS

M

EA

SU

R

EM

EN

T D

O

ES

N O

T M

AT

C

H W

H

AT

IS

S

H O

W N

, T H

E

SH

EE

T

SI

ZE

H

AS

B

EE

N M

O D

IF

IE

D F

R O

M : A

N

SI

B

Pa th

\g ol de r.g ds

\c om pl ex da ta

\O ffi ce \J ac ks on vi lle \d ra fti ng \F ile \F

D

EP

\F D

EP

-D

C \D

C N o

Sw ift C le an er s\

J

- 2

An nu al G

W R pt \A ct iv e D ra w in gs

Fi le

N am e:

F

D

EP

-D C

8-

J0

.d w g

1. BASE MAP TAKEN FROM CADD FILE PREPARED BY ABB ENVIRONMENTAL

SERVICES INC. TITLED "SITE AREA MAP", FILE NAME "FIG3.dxf", DATED

DECEMBER 1997.

LEGEND

REFERENCE(S)

SCALE

0 40 80

FEET

1. ALL RESULTS ARE REPORTED IN MICROGRAMS PER LITER (ug/L).

2. U - INDICATES THAT THE COMPOUND WAS ANALYZED FOR BUT NOT

DETECTED.

3. I - THE REPORTED VALUE IS BETWEEN THE LABORATORY METHOD

DETECTION LIMIT AND THE LABORATORY PRACTICAL QUANTITATION LIMIT.

4. V - INDICATES ANALYTE WAS DETECTED IN BOTH THE SAMPLE AND THE

ASSOCIATES METHOD BLANK.

5. BOLD FONT AND YELLOW SHADED CELL INDICATE AN EXCEEDANCE OF THE

APPLICABLE GCTL.

6. * - RESULT DETERMINED NOT TO EXCEED THE GCTL BASED ON THE FDEP

MEMORANDUM "ROUNDING ANALYTICAL DATA FOR SITE REHABILITATION

COMPLETION", DATED NOVEMBER 17, 2011.

NOTE(S)

Salon Hair

Cleaners Swift

Center Medical Animal

TR

O

LL

IE

L

AN

E

MERRILL ROAD

C

ES

ER

Y

BO

U

LE

VA

R D

GREEN PALM LANE

ST

AR

D U

ST

C

O U

R T

Lake Lucina Center

Po ol

Burger King

MW-017

MW-020

MW-015

MW-032

MW-035

MW-011

MW-029

MW-013

MW-033

MW-005

MW-008

MW-002 MW-038

MW-041

MW-036

MW-039

MW-040

MW-044

MW-045

MW-047

MW-046

MW-048

MW-042

MW-006

MW-027

MW-023

MW-043

MW-005

MAR 2018 MAR 2019 MAR 2020 FEB 2021

71 75 160 167 12 14 16 18.8

0.36 U 0.36 U 0.36 U 0.32 U

0.36 U 0.36 U 0.36 U 0.30 U

MW-015

APR 1997

1.0 U

1.0 U

1.0 U

1.0 U

MW-038

APR 2009 MAR 2017 MAR 2018 MAR 2019

14 98 50 51

2.8 8.0 2.8 9.0

0.17 U 0.65 U 0.36 U 1.8 U

0.16 U 0.71 U 0.36 U 1.8 U

MW-039

JUN 2001 APR 2002 FEB 2003

97.7 14.5 2.3

1.0 U 1.0 U 1.0 U

1.0 U 1.0 U 1.0 U

1.0 U 1.0 U 1.0 U

MW-008

SEP 2004 MAY 2006 DEC 2007

0.17 I 0.79 I 0.63 I

0.17 U 0.41 I 0.56 I

0.090 U 0.18 U 0.18 U

0.25 U 0.29 U 0.058 U

MW-002

SEP 2004 MAY 2006 DEC 2007

3.1* 2.4 0.63 I

0.17 U 0.57 I 0.13 U

0.090 U 0.18 U 0.18 U

0.25 U 0.29 U 0.058 U

MW-043

SEP 2004 MAY 2006 DEC 2007

2.2 6.7 0.58 I

0.25 I 0.71 I 0.22 I

0.090 U 0.18 U 0.18 U

0.25 U 0.29 U 0.058 U

MW-020

SEP 2004 MAY 2006 DEC 2007

9.1 2.2 0.24 U

2.3 0.71 I 0.29 I

0.090 U 0.18 U 0.18 U

0.25 U 0.29 U 0.058 U

MW-017

DEC 2007 APR 2009 MAR 2010 MAR 2015

12 7.5 15 2.2

0.82 I 1.2 0.94 I 0.48 U

0.18 U 0.17 U 0.22 U 0.41 U

0.058 U 0.16 U 0.29 U 0.50 U

MW-035

FEB 2012 JAN 2013 FEB 2014 MAR 2019

16 1.0 0.50 U 0.22 U

1.30 0.16 U 0.50 U 0.36 U

0.22 U 0.21 U 0.65 U 0.36 U

0.29 U 0.22 U 0.50 U 0.36 U

MW-023

DEC 2007 MAR 2019 MAR 2020 FEB 2021

0.24 U 0.28 I 0.22 U 0.35 U

0.13 UJ 0.36 U 0.36 U 0.33 U

0.18 UJ 0.36 U 0.36 U 0.32 U

0.058 UJ 0.36 U 0.36 U 0.30 U

MW-033

SEP 2004 MAY 2006 DEC 2007 MAR 2016

16 4.4 4.5 1.9

0.67 I 0.97 I 0.66 I 0.61 U

0.090 U 0.18 U 0.18 U 0.65 U

0.25 U 0.29 U 0.058 U 0.71 U

MW-029

DEC 2007 MAR 2017 MAR 2020 FEB 2021

9.4 4.2 3.1 * 3.1 *

1.2 V 1.2 1.9 1.1

0.18 U 0.65 U 0.36 U 0.32 U

0.058 U 0.71 U 0.36 U 0.30 U

MW-040

MAR 2010 MAR 2016 MAR 2017 MAR 2018

150 170 78 33

3.4 I* 12 6.4 3.0

1.1 U 0.65 U 0.65 U 0.36 U

1.4 U 0.71 U 0.71 U 0.36 U

MW-041

SEP 2004 MAY 2006 DEC 2007

7.3 2.4 0.61 I

2.9 0.32 I 0.13 U

0.090 U 0.18 U 0.18 U

0.25 U 0.29 U 0.058 U

MW-011

SEP 2004 MAY 2006 DEC 2007

2.6 0.64 I 0.34 I

0.17 U 0.11 U 0.19 IV

0.090 U 0.18 U 0.18 U

0.25 U 0.29 U 0.058 U

MW-013

MAR 2018 MAR 2019 MAR 2020 FEB 2021

10 11 10 6.1

0.36 U 2.1 1.8 1.1

0.36 U 0.36 U 0.36 U 0.32 U

0.36 U 0.36 U 0.36 U 0.30 U

MW-042

FEB 2003

13.7

1.0 U

1.0 U

1.0 U

cis-1,2-DICHLOROETHENE (cis-1,2-DCE)

TRICHLOROETHENE (TCE)

TETRACHLOROETHENE (PCE)

MW0XX

DEC 2007 DEC 2007

3 300 3 300

70 700 1 100

MONITORING WELL I.D.

SAMPLE DATE

VINYL CHLORIDE (VC)

GROUNDWATER CLEANUP TARGET

LEVELS (GCTLs)

NATURAL ATTENUATION DEFAULT

CONCENTRATIONS (NADCs)

MONITORING WELL LOCATIONS

PROPERTY LINE

in

FDEP-DC018M

Control No.

FDEP-DC018-J007

FIGURE

2021-03-10

BCL

RFM

RFM

JCB

2021 GROUNDWATER MONITORING REPORT

SWIFT CLEANERS

INTERMEDIATE ZONE SURFICIAL AQUIFER

(+10 TO +25 FEET MSL)

TITLE

PROJECT NO. REV.

PROJECT

CLIENT

CONSULTANT

PREPARED

DESIGNED

REVIEWED

APPROVED

YYYY-MM-DD

IF

T

H

IS

M

EA

SU

R

EM

EN

T D

O

ES

N O

T M

AT

C

H W

H

AT

IS

S

H O

W N

, T H

E

SH

EE

T

SI

ZE

H

AS

B

EE

N M

O D

IF

IE

D F

R O

M : A

N

SI

B

Pa th

\g ol de r.g ds

\c om pl ex da ta

\O ffi ce \J ac ks on vi lle \d ra fti ng \F ile \F

D

EP

\F D

EP

-D

C \D

C N o

Sw ift C le an er s\

J

- 2

An nu al G

W R pt \A ct iv e D ra w in gs

Fi le

N am e:

F

D

EP

-D C

8-

J0

.d

DECEMBER 1997.

LEGEND

REFERENCE(S)

SCALE

0 40 80

FEET

1. ALL RESULTS ARE REPORTED IN MICROGRAMS PER LITER (ug/L).

2. U - INDICATES THAT THE COMPOUND WAS ANALYZED FOR BUT NOT

DETECTED.

3. I - THE REPORTED VALUE IS BETWEEN THE LABORATORY METHOD

DETECTION LIMIT AND THE LABORATORY PRACTICAL QUANTITATION LIMIT.

4. V - INDICATES ANALYTE WAS DETECTED IN BOTH THE SAMPLE AND THE

ASSOCIATES METHOD BLANK.

5. J - ESTIMATED VALUE.

6. BOLD FONT AND YELLOW SHADED CELL INDICATE AN EXCEEDANCE OF THE

APPLICABLE GCTL.

7. * - RESULT DETERMINED NOT TO EXCEED THE GCTL BASED ON THE FDEP

MEMORANDUM "ROUNDING ANALYTICAL DATA FOR SITE REHABILITATION

COMPLETION", DATED NOVEMBER 17, 2011.

GCTL CONTOUR

Salon Hair

Cleaners Swift

Center Medical Animal

TR

O

LL

IE

L

AN

E

MERRILL ROAD

C

ES

ER

Y

BO

U

LE

VA

R D

GREEN PALM LANE

ST

AR

D U

ST

C

O U

R T

Lake Lucina Center

Po ol

Burger King

MW-041

MW-036

MW-037

MW-016

MW-021

MW-022

MW-018

MW-030

MW-014

MW-045

MW-047

MW-046

MW-006

MW-009

MW-048

MW-044

MW-003

MW-039

MW-040

MW-042

MW-043

MW-024

MW-033

MW-038

MW-034

MW-006

MAR 2018 MAR 2019 MAR 2020 FEB 2021

110 110 160 411 17 18 25 24.1

0.36 U 0.36 U 0.36 U 0.32 U

0.36 U 0.36 U 0.36 U 0.30 U

MW-009

SEP 2004 MAY 2006 DEC 2007

0.17 U 0.18 U 0.24 U

0.17 U 0.11 U 0.23 IV

0.090 U 0.18 U 0.18 U

0.25 U 0.29 U 0.058 U

MW-003

SEP 2004 MAY 2006 DEC 2007

95 6.5 3.7

6.0 1.5 1.7 V

0.090 U 0.9 I 0.18 U

0.25 U 0.29 U 0.058 U

MW-044

SEP 2004 MAY 2006 DEC 2007

240 3.3* 8.1

6.4 0.46 I 3.0 V

0.14 U 0.18 U 0.18 U

0.25 U 0.29 U 0.058 U

MW-022

APR 2009 MAR 2010 MAR 2016 MAR 2017

44 36 7.1 8.1

1.3 0.83 I 0.61 U 0.61 U

0.17 U 0.22 U 0.65 U 0.65 U

0.16 U 0.29 U 0.71 U 0.71 U

MW-037

MAR 2018 MAR 2019 MAR 2020 FEB 2021

760 720 390 524 32 18 U 32 27.3

0.41 I 18 U 1.8 U 0.32 U

0.36 U 18 U 1.8 U 0.30 U

MW-034

MAY 2006 DEC 2007 MAR 2016 MAR 2018

120 14 140 71 37 11 170 130

0.18 U 0.18 U 9.5 18

0.29 U 0.058 U 0.71 U 0.36 U

MW-030

MAY 2006 DEC 2007 MAR 2020 FEB 2021

13 35 67 70.8

3.5 12 V 16 18.4

0.18 U 0.18 U 3.6 U 0.32 U

0.29 U 0.058 U 3.6 U 0.30 U

MW-014

SEP 2004 MAY 2006 DEC 2007 MAR 2016

110 110 24 17 17 15 5.7 V 6.0

1.7 2.4 0.18 U 0.65 U

0.25 U 0.29 U 0.058 U 0.71 U

MW-046

SEP 2004 MAY 2006 DEC 2007

54 300 57 12 12 I 9.4 V

0.090 U 3.6 U 0.18 U

0.25 U 5.8 U 0.058 U

MW-045

SEP 2004 MAY 2006 MAR 2019

57 45 4.3

4.0 1.8 6.9

0.090 U 0.18 U 0.59 I

0.25 U 0.29 U 0.36 U

MW-047

SEP 2004 MAY 2006

190 40 60 5.2

0.090 U 0.18 U

0.25 U 0.29 U

MW-048

MAY 2006 DEC 2007 MAR 2020 FEB 2021

55 37 50 259

5.0 11 12 17.6

0.18 U 0.18 U 0.36 U 0.32 U

0.29 U 0.058 U 0.36 U 0.30 U

MW-016

SEP 2004 MAY 2006 DEC 2007

1.7 0.74 I 0.24 U

1.2 0.68 I 0.37 IJ

1.3 0.18 U 0.18 UJ

0.25 U 0.29 U 0.058 UJ

MW-018

MAR 2017 MAR 2019 MAR 2020 FEB 2021

130 180 190 49.6 27 69 53 30.1

0.65 U 3.6 U 3.6 U 4.9

0.71 U 3.6 U 3.6 U 0.30 U

MW-036

SEP 2004 MAY 2006 DEC 2007 MAR 2019

350 110 59 11

5.3 2.5 2.8 I 1.0

0.090 U 0.18 U 0.90 U 0.36 U

0.25 U 0.29 U 0.29 U 0.36 U

MW-024

MAR 2018 MAR 2019 MAR 2020 FEB 2021

42 64 41 58.2 (1)

0.36 U 10 2.9 I 3.1 *

0.36 U 1.8 U 1.8 U 0.32 U

0.36 U 1.8 U 1.8 U 0.30 U

cis-1,2-DICHLOROETHENE (cis-1,2-DCE)

TRICHLOROETHENE (TCE)

TETRACHLOROETHENE (PCE)

MW0XX

MAR 2016 MAR 2016

3 300 3 300

70 700 1 100

MONITORING WELL I.D.

SAMPLE DATE

VINYL CHLORIDE (VC)

GROUNDWATER CLEANUP TARGET

LEVELS (GCTLs)

NATURAL ATTENUATION DEFAULT

CONCENTRATIONS (NADCs)

MONITORING WELL LOCATIONS

PROPERTY LINE

in

FDEP-DC018M

Control No.

FDEP-DC018-J008

FIGURE

2021-03-10

BCL

RFM

RFM

JCB

2021 GROUNDWATER MONITORING REPORT

SWIFT CLEANERS

DEEP ZONE SURFICIAL AQUIFER

(-5 TO +10 FEET MSL)

TITLE

PROJECT NO. REV.

PROJECT

CLIENT

CONSULTANT

PREPARED

DESIGNED

REVIEWED

APPROVED

YYYY-MM-DD

IF

T

H

IS

M

EA

SU

R

EM

EN

T D

O

ES

N O

T M

AT

C

H W

H

AT

IS

S

H O

W N

, T H

E

SH

EE

T

SI

ZE

H

AS

B

EE

N M

O D

IF

IE

D F

R O

M : A

N

SI

B

Pa th

\g ol de r.g ds

\c om pl ex da ta

\O ffi ce \J ac ks on vi lle \d ra fti ng \F ile \F

D

EP

\F D

EP

-D

C \D

C N o

Sw ift C le an er s\

J

- 2

An nu al G

W R pt \A ct iv e D ra w in gs

Fi le

N am e:

F

D

EP

-D C

8-

J0

.d

DECEMBER 1997.

LEGEND

REFERENCE(S)

SCALE

0 40 80

FEET

1. ALL RESULTS ARE REPORTED IN MICROGRAMS PER LITER (ug/L).

2. U - INDICATES THAT THE COMPOUND WAS ANALYZED FOR BUT NOT

DETECTED.

3. I - THE REPORTED VALUE IS BETWEEN THE LABORATORY METHOD

DETECTION LIMIT AND THE LABORATORY PRACTICAL QUANTITATION LIMIT.

4. V - INDICATES ANALYTE WAS DETECTED IN BOTH THE SAMPLE AND THE

ASSOCIATES METHOD BLANK.

5. J - ESTIMATED VALUE.

6. BOLD FONT AND YELLOW SHADED CELL INDICATE AN EXCEEDANCE OF THE

APPLICABLE GCTL.

7. BOLD FONT AND BLUE SHADED CELL INDICATE AN EXCEEDANCE OF THE

APPLICABLE NADC.

8. * - RESULT DETERMINED NOT TO EXCEED THE GCTL BASED ON THE FDEP

MEMORANDUM "ROUNDING ANALYTICAL DATA FOR SITE REHABILITATION

COMPLETION", DATED NOVEMBER 17, 2011.

9. ** - TEMPORARY POINT OF COMPLIANCE WELL.

10. (1) - PCE CONTROL SAMPLE WAS SLIGHTLY OUTISDE THE CONTROL LIMITS.

NOTE(S)

NADC CONTOUR

Salon Hair

Cleaners Swift

Center Medical Animal

TR

O

LL

IE

L

AN

E

MERRILL ROAD

C

ES

ER

Y

BO

U

LE

VA

R D

GREEN PALM LANE

ST

AR

D U

ST

C

O U

R T

Lake Lucina Center

Po ol

Burger King

MW-019

MW-031

MW-019

DEC 2007 JAN 2011 FEB 2012 JAN 2013

0.24 U 0.26 U 0.20 U 0.19 U

0.45 IVJ 0.47 I 0.26 U 0.16 U

0.18 UJ 0.22 U 0.22 U 0.21 U

0.058 UJ 0.29 U 0.29 U 0.22 U

MW-031

MAR 2018 MAR 2019 MAR 2020 FEB 2021

120 110 180 139

2.3 4.4 I 22 8.7

1.1 1.8 I 1.8 U 1.6

0.36 U 1.8 U 1.8 U 0.30 U

cis-1,2-DICHLOROETHENE (cis-1,2-DCE)

TRICHLOROETHENE (TCE)

TETRACHLOROETHENE (PCE)

MW0XX

JAN 2011 JAN 2011

3 300 3 300

70 700 1 100

MONITORING WELL I.D.

SAMPLE DATE

VINYL CHLORIDE (VC)

GROUNDWATER CLEANUP TARGET

LEVELS (GCTLs)

NATURAL ATTENUATION DEFAULT

CONCENTRATIONS (NADCs)

MONITORING WELL LOCATIONS

PROPERTY LINE

in

FDEP-DC018M

Control No.

FDEP-DC018-J009

FIGURE

2021-03-10

BCL

RFM

RFM

JCB

2021 GROUNDWATER MONITORING REPORT

SWIFT CLEANERS

ROCK ZONE SURFICIAL AQUIFER

(-20 TO -5 FEET MSL)

TITLE

PROJECT NO. REV.

PROJECT

CLIENT

CONSULTANT

PREPARED

DESIGNED

REVIEWED

APPROVED

YYYY-MM-DD

IF

T

H

IS

M

EA

SU

R

EM

EN

T D

O

ES

N O

T M

AT

C

H W

H

AT

IS

S

H O

W N

, T H

E

SH

EE

T

SI

ZE

H

AS

B

EE

N M

O D

IF

IE

D F

R O

M : A

N

SI

B

Pa th

\g ol de r.g ds

\c om pl ex da ta

\O ffi ce \J ac ks on vi lle \d ra fti ng \F ile \F

D

EP

\F D

EP

-D

C \D

C N o

Sw ift C le an er s\

J

- 2

An nu al G

W R pt \A ct iv e D ra w in gs

Fi le

N am e:

F

D

EP

-D C

8-

J0

.d

DECEMBER 1997.

LEGEND

REFERENCE(S)

SCALE

0 40 80

FEET

1. ALL RESULTS ARE REPORTED IN MICROGRAMS PER LITER (ug/L).

2. U - INDICATES THAT THE COMPOUND WAS ANALYZED FOR BUT NOT

DETECTED.

3. I - THE REPORTED VALUE IS BETWEEN THE LABORATORY METHOD

DETECTION LIMIT AND THE LABORATORY PRACTICAL QUANTITATION LIMIT.

4. V - INDICATES ANALYTE WAS DETECTED IN BOTH THE SAMPLE AND THE

ASSOCIATES METHOD BLANK.

5. J - ESTIMATED VALUE.

6. BOLD FONT AND YELLOW SHADED CELL INDICATE AN EXCEEDANCE OF THE

APPLICABLE GCTL.

7. ** - TEMPORARY POINT OF COMPLIANCE WELL.

TR

O

LL

IE

L A

N E

M E R R I L L R O A D

C

ES

ER

Y

B O

U

LE

VA

R

D

ST

A

R D

U

ST

C O

U R

T

U N

I V

E R

S I

T Y

B

L V

D

RIVER CITY LANDING

APARTMENT COMPLEX LAKE

MW-051

MAR 2018 MAR 2019 MAR 2020 FEB 2021

0.22 U 0.22 U 0.22 U 0.35 U

0.36 U 0.36 U 0.36 U 0.33 U

0.36 U 0.36 U 0.36 U 0.32 U

0.36 U 0.36 U 0.36 U 0.30 U

cis-1,2-DICHLOROETHENE (cis-1,2-DCE)

TRICHLOROETHENE (TCE)

TETRACHLOROETHENE (PCE)

MW0XX

FEB 2014 FEB 2014

3 300 3 300

70 700 1 100

MONITORING WELL I.D.

SAMPLE DATE

VINYL CHLORIDE (VC)

GROUNDWATER CLEANUP TARGET LEVELS (GCTLs)

NATURAL ATTENUATION DEFAULT CONCENTRATIONS (NADCs)

MONITORING WELL LOCATIONS

PROPERTY LINE

MW-050

MAR 2018 MAR 2019 MAR 2020 FEB 2021

0.22 U 0.22 U 0.22 U 0.35 U

0.36 U 0.36 U 0.36 U 0.33 U

0.36 U 0.36 U 0.36 U 0.32 U

0.36 U 0.36 U 0.36 U 0.30 U

in

FDEP-DC018M

Control No.

FDEP-DC018-J010

FIGURE

2021-03-10

BCL

RFM

RFM

JCB

2021 GROUNDWATER MONITORING REPORT

SWIFT CLEANERS

TPOC WELLS

TITLE

PROJECT NO. REV.

PROJECT

CLIENT

CONSULTANT

PREPARED

DESIGNED

REVIEWED

APPROVED

YYYY-MM-DD

IF

T

H

IS

M

EA

SU

R

EM

EN

T D

O

ES

N O

T M

AT

C

H W

H

AT

IS

S

H O

W N

, T H

E

SH

EE

T

SI

ZE

H

AS

B

EE

N M

O D

IF

IE

D F

R O

M : A

N

SI

B

Pa th

\g ol de r.g ds

\c om pl ex da ta

\O ffi ce \J ac ks on vi lle \d ra fti ng \F ile \F

D

EP

\F D

EP

-D

C \D

C N o

Sw ift C le an er s\

J

- 2

An nu al G

W R pt \A ct iv e D ra w in gs

Fi le

N am e:

F

D

EP

-D C

8-

J0

.d

1. ROADS DIGITIZED FROM AERIAL PROVIDED BY COURTESY OF FLORIDA DEPT.

OF TRANSPORTATION WEB SITE DATED 2010.

2. PROPERTY LINES PROVIDED BY COURTESY OF CITY OF JACKSONVILLE

PROPERTY APPRAISERS OFFICE WEB SITE DATED 2006.

LEGEND

REFERENCE(S)

SCALE

0 75 150

FEET

1. ALL RESULTS ARE REPORTED IN MICROGRAMS PER LITER (ug/L).

2. U - INDICATES THAT THE COMPOUND WAS ANALYZED FOR BUT NOT

DETECTED.

NOTE(S)

AutoCAD SHX Text

MW014

AutoCAD SHX Text

MW030

AutoCAD SHX Text

MW006

AutoCAD SHX Text

MW018

AutoCAD SHX Text

MW024

AutoCAD SHX Text

MW016

AutoCAD SHX Text

MW022

AutoCAD SHX Text

MW009

AutoCAD SHX Text King

AutoCAD SHX Text Burger

AutoCAD SHX Text Salon

AutoCAD SHX Text Hair

AutoCAD SHX Text Cleaners

AutoCAD SHX Text Swift

AutoCAD SHX Text Pool

AutoCAD SHX Text Center

AutoCAD SHX Text Medical

AutoCAD SHX Text Animal

AutoCAD SHX Text

MW036

AutoCAD SHX Text

MW037

AutoCAD SHX Text

GREEN PALM LANE

AutoCAD SHX Text

MW046

AutoCAD SHX Text

MW034

AutoCAD SHX Text

MW047

AutoCAD SHX Text

MW045

AutoCAD SHX Text

MW048

AutoCAD SHX Text

MW044

AutoCAD SHX Text

MW043

AutoCAD SHX Text

MW039

AutoCAD SHX Text

MW040

AutoCAD SHX Text

MW038

AutoCAD SHX Text

MW042

AutoCAD SHX Text

MW041

AutoCAD SHX Text

MW003

AutoCAD SHX Text

MW015

AutoCAD SHX Text

MW031

AutoCAD SHX Text

MW023

AutoCAD SHX Text

MW051

AutoCAD SHX Text

MW050

From: Fred Portofe To: Mongillo, Ralph Cc: Madison Rogers; Roger Pragle; Crews, Matt Subject: RE: Investigative Derived Waste Drum Costs for Transportation and Disposal at a Regulated Facility Date: Wednesday, March 9, 2022 9:33:38 AM Attachments: F0152F28A2B5418EBC7A4FD870EC8D28.png

AD282F6C3391468088CDA42829B8E703.png A719914B10184314957B0CA910CA8D14.png F1DF3C4322764E8A9076F1ADFF76864A.png 3409DF389C3B4156BA232DDC85C60E09.png

EXTERNAL EMAIL

EXTERNAL EMAIL - We could not verify the authenticity of this message. Please be cautious when clicking on links or opening attachments.

Ralph

We are not going to provide annual Pricing for the Statewide Contract . After reviewing the scope with my partners and the variability with respect to disposal costing and ever changing fuel costs, we feel we can not bid this work given the current uncertainty in the market. We would be please to bid this work on a casa by case basis.

Fred G. Portofe, PG President of Environmental Services (Professional Geologist in FL, GA, AL, MS, TX, SC, NC, TN, IN, LA, WI and AK) M & D Industrial Services, LLC 5896 Azalea Street Port Orange, Florida 32127 Email: Fportofe@mdindustrialservices.com Website: mdindustrialservices.com Cell: 813-951-1012 Emergencies: 888-307-2790

Sent from Mail for Windows

From: Mongillo, Ralph Sent: Tuesday, March 8, 2022 12:46 PM To: Fred Portofe Cc: Madison Rogers; Roger Pragle; Eddy Mendoza; Crews, Matt mailto:fportofe@mdindustrialservices.com mailto:ralph.mongillo@wsp.com mailto:mrogers@mdindustrialservices.com mailto:rpragle@mdindustrialservices.com mailto:matt.crews@wsp.com mailto:Fportofe@mdindustrialservices.com https://nam10.safelinks.protection.outlook.com/?url=http%3A%2F%2Fmdindustrialservices.com%2F&data=04%7C01%7Cmculbreth%40ectinc.com%7Cbfdc4a6d2ce945e1eaf008d9dcf8eabf%7C911eb1cc54d34d8ca5773bf3ccc8105c%7C0%7C0%7C637783784008834159%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C2000&sdata=ntkZP1OGe7McYRA722JXtcGwkbgN9EEhQtSgBSKqC3E%3D&reserved=0 https://go.microsoft.com/fwlink/?LinkId=550986 mailto:Ralph_Mongillo@golder.com mailto:fportofe@mdindustrialservices.com mailto:mrogers@mdindustrialservices.com mailto:rpragle@mdindustrialservices.com mailto:emendoza@mdindustrialservices.com mailto:Matt_Crews@golder.com

File details come from the government source that posted it. Updated .