JA-6_AF_Form_66_-_10_Apr_'15.pdf

PDF 116 KB Posted

Attached to
CH&PP Fire Alarm System Repair Federal contract opportunity
Solicitation number
FA5004-15-R-C006
Issued by
Department of the Air Force Pacific Air Forces

About this file

JA-6 AF Form 66

View the file

Other files for this federal contract opportunity

Other files attached to CH&PP Fire Alarm System Repair, newest first.
File Type Posted
Questions_and_Answers_0001.pdf PDF
Amendment_0002.pdf PDF
JA-1_Specifications_(9_July_2015).pdf PDF
Amendment_0001.pdf PDF
CHPP_Fire_Alarm_JA_Signed.pdf PDF
JA-4_Past_Performance_Questionnaire.pdf PDF
JA-1_Specifications.pdf PDF
JA-10_Financial_Reference_Sheet.pdf PDF
JA-2_Drawings_22x34.pdf PDF
FA5004-15-R-C006.pdf PDF
JA-9_AF_Form_3065 _Contract_Progress_Report.pdf PDF
JA-5_Past_Performance_Worksheet.pdf PDF
JA-7_AF_Form_3000 _Material_Approval_Submittal.pdf PDF
JA-8_AF_Form_3064 _Contract_Progress_Schedule.pdf PDF
JA-3_Wage_Determination_Building_and_Heavy_AK1.pdf PDF
Show all 15

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ITEMS OR DESCRIPTION

OF ITEM, CONTRACT REFERENCE,

TYPE OF

SUBMITTAL

APPROVED DIS-APPROVED

01 10 00 DESCRIPTION OF WORK AND COORDINATION

AF Form 103

01 10 00 1.11.A 3 NLT 1 day before work begins

Notification of Commencement of Work

01 10 00 1.11.B. 3 NLT 7 days beefore work begins

01 14 00 SAFETY, ENVIRONMENTAL PROTECTION

REGULATIONS, AND CODES

Construction Operation and Safety Plan

01 14 00 1.4.A.1 & 1.7 3 30 days prior to work start

Accident Prevention Plan

01 14 00 1.4.A.2 & 1.8 3 30 days prior to work start

Safety and Health Program

01 14 00 1.4.A.3 & 1.9 & 02 05 50 1.5.B 4 30 days prior to work start

Contractor's Respiratory Protection Program

01 14 00 1.8.C.9.f. & 02 05 50 1.5.C 4 30 days before work begins

Contractor's Hazard Communication Program

01 14 00 1.9.M. & 02 05 50 1.5.D 4 30 days before work begins

Environmental Protection Plan

01 14 00 1.4.A.4 & 1.13 4 3 weeks prior to commencing construction activities

Hazardous Materials Inventory (Initial, quarterly and final) with

MSDSs

01 14 00 1.4.A.5 & 1.14.A 4 4

With Enviro

Protection Plan &

Quarterly

Hazardous Waste Accumulation Log (Initial, quarterly and final)

01 14 00 1.4.A.6 & 1.15.C

NLT 7 days after accumulation of waste begins

Laboratory Test Results (as applicable)

01 14 00 1.4.A.7 & 1.16.A 4 Prior to disposal of

Haz Waste

NOI for Asbestos Abatement (if required)

01 14 00 1.4.A.8 & 1.19.B 4 NLT 10 days before abatement begins

01 40 00 QUALITY CONTROL

Testing Laboratory Information

01 40 00 1.3.A,B,C,D,E 4 NLT 14 days prior to any testing

Construction Photos

01 40 00 1.7.E 3 With each progress report

01 70 00 CONTRACT CLOSEOUT

Project Record Documents

01 70 00 1.4.F & 26 05 09 3 prior to final inspection

Interim DD Form 1354

01 70 00 1.4.H 3 Prior to final inspection

Final DD Form 1354

01 70 00 1.4.I 3 Prior to final payment

Final As-Built Dwgs

01 70 00 1.4.I 3 Prior to final payment

Fire Protection Equipment Operation and Maintenance Data

01 70 00 1.5.A.1 & 26 05 09 4 4 4 4 7 days prior to training

SCHEDULE OF MATERIAL SUBMITTALS

PROJECT NUMBER PROJECT TITLE SOLICITATION/ CONTRACT NUMBER

Repair CH&PP Fire

Alarm System

FA5004-15-R-C006FTQW 08-1025

M S

D S

TO BE COMPLETED BY PROJECT ENGINEER

TO BE COMPLETED BY CONTRACT ADMINISTRATOR

NUMBER OF COPIES REQUIRED =

R E

Q U

IR

E

D S

U B

M

IS

S

IO

N D

A T

E

L in e N u m b e r

C E

R T

IF

IC

A T

IO

N

O F

C O

M P

L

IA

N C

E

S H

O P

D R

A W

IN

G

S

S A

M P

L E

S

C O

L O

R S

E L

E C

T

IO

N

M A

N U

F A

C T

U R

E R

'S R

E C

O M

M E

N D

A T

IO

N

S

F

IN

A L A

P P

R O

V A

L

REMARKS

NOTIFIED

R E

T U

R N

S U

S P

E N

S E

D A

T E

S U

B M

IT

T

A L

N U

M B

E R

DATE CONTRACTOR

C O

N T

R A

C T

O R

R E

S U

B M

IT

T

A L

O T

H E

R

P L

A N

S

D A

T E

R E

C E

IV

E

D I N

C O

N T

R A

C T

IN

G

D A

T E

T O

C

IV

IL

E

N G

IN

E

E R

IN

G

M A

N U

F A

C T

U R

E R

'S W

A R

R A

N T

Y

C A

T A

L O

G D

A T

A

O P

E R

A T

IN

G

I N

S T

R U

C T

IO

N

S

JA-6

OF ITEM, CONTRACT REFERENCE,

TYPE OF

SUBMITTAL

APPROVED DIS-APPROVED

SCHEDULE OF MATERIAL SUBMITTALS

PROJECT NUMBER PROJECT TITLE SOLICITATION/ CONTRACT NUMBER

Repair CH&PP Fire

Alarm System

FA5004-15-R-C006FTQW 08-1025

M S

D S

TO BE COMPLETED BY PROJECT ENGINEER

TO BE COMPLETED BY CONTRACT ADMINISTRATOR

NUMBER OF COPIES REQUIRED =

R E

Q U

IR

E

D S

U B

M

IS

S

IO

N D

A e N u m b e r

C E

R T

IF

IC

A T

IO

N

O F

C O

M P

L

IA

N C

E

S H

O P

D R

A W

IN

G

S

S A

M P

L E

S

C O

L O

R S

E L

E C

T

IO

N

M A

N U

F A

C T

U R

E R

'S R

E C

O M

M E

N D

A T

IO

N

S

F

IN

A L A

P P

R O

V A

L

REMARKS

NOTIFIED

R E

T U

R N

S U

S P

E N

S E

D A

T E

S U

B M

IT

T

A L

N U

M B

E R

DATE CONTRACTOR

C O

N T

R A

C T

O R

R E

S U

B M

IT

T

A L

O T

H E

R

P L

A N

S

D A

T E

R E

C E

IV

E

D I N

C O

N T

R A

C T

IN

G

D A

T E

T O

C

IV

IL

E

N G

IN

E

E R

IN

G

M A

N U

F A

C T

U R

E R

'S W

A R

R A

N T

Y

C A

T A

L O

G D

A T

A

O P

E R

A T

IN

G

I N

S T

R U

C T

IO

N

S

Warranties

01 70 00 1.6 3 Prior to final payment

Spare Parts and Maintenance Materials

01 70 00 1.7 1 Prior to final payment

01 73 29 CUTTING AND PATCHING

Written Request - Cutting or Alteration

01 73 29 1.2.A 3 NLT 7 days before work begins Submit only if applicable.

02 05 50 DEMOLITION

Demolition Work Plan

02 05 50 1.5.A 3 30 days before work begins

Receipts for Disposal of all Materials

02 05 50 1.5.E 3 Within 14 days after disposal of materials

26 12 00 Low-Voltage Transformers

Transformers

26 12 00 1.2.A & 2.2 3 30 days before placing order

26 24 18 Branch Circuit Panelboards

Branch Panelboards

26 24 18 1.2.A, 1.2.B & 2.2.A 3 30 days before placing order

Branch Circuit Breakers

26 24 18 1.2.A, 1.2.B & 2.3 3 30 days before placing order

28 31 00 ADDRESSABLE FIRE ALARM SYSTEM

Fire Alarm Control Panel

28 31 00 1.5.A & 2.2.A 3 30 days before placing order

Alarm Initiation Devices

28 31 00 1.5.A & 2.2.B 3 30 days before placing order

Alarm Notification Devices

28 31 00 1.5.A & 2.2.C 3 30 days before placing order

Fire Suppression Releasing Panel

28 31 00 1.5.A & 2.2.D 3 30 days before placing order

Releasing Initiation Devices

28 31 00 1.5.A & 2.2.D.3 3 30 days before placing order

Ancillary Devices

28 31 00 1.5.A & 2.2.D.4 3 30 days before placing order

Fire Alarm System Map

28 31 00 1.5.A & 2.3 3 NLT 7 days prior to training

Fire Alarm Branch Circuit Conductors

28 31 00 1.5.A & 2.4 3 30 days before placing order

Operating Instructions

28 31 00 1.5.B 4 7 days prior to training

Schematic Diagrams for All Equipment

28 31 00 1.5.C 3 30 days before placing order

Shop Drawings

28 31 00 1.5.D 3 30 days before installation

Calculations Verifying the Standby Battery Capacity

28 31 00 1.5.E 3 With shop drawings

OF ITEM, CONTRACT REFERENCE,

TYPE OF

SUBMITTAL

APPROVED DIS-APPROVED

SCHEDULE OF MATERIAL SUBMITTALS

PROJECT NUMBER PROJECT TITLE SOLICITATION/ CONTRACT NUMBER

Repair CH&PP Fire

Alarm System

FA5004-15-R-C006FTQW 08-1025

M S

D S

TO BE COMPLETED BY PROJECT ENGINEER

TO BE COMPLETED BY CONTRACT ADMINISTRATOR

NUMBER OF COPIES REQUIRED =

R E

Q U

IR

E

D S

U B

M

IS

S

IO

N D

A e N u m b e r

C E

R T

IF

IC

A T

IO

N

O F

C O

M P

L

IA

N C

E

S H

O P

D R

A W

IN

G

S

S A

M P

L E

S

C O

L O

R S

E L

E C

T

IO

N

M A

N U

F A

C T

U R

E R

'S R

E C

O M

M E

N D

A T

IO

N

S

F

IN

A L A

P P

R O

V A

L

REMARKS

NOTIFIED

R E

T U

R N

S U

S P

E N

S E

D A

T E

S U

B M

IT

T

A L

N U

M B

E R

DATE CONTRACTOR

C O

N T

R A

C T

O R

R E

S U

B M

IT

T

A L

O T

H E

R

P L

A N

S

D A

T E

R E

C E

IV

E

D I N

C O

N T

R A

C T

IN

G

D A

T E

T O

C

IV

IL

E

N G

IN

E

E R

IN

G

M A

N U

F A

C T

U R

E R

'S W

A R

R A

N T

Y

C A

T A

L O

G D

A T

A

O P

E R

A T

IN

G

I N

S T

R U

C T

IO

N

S

Calculations for Voltage Drop and Wire Sizing

28 31 00 1.5.F 3 With shop drawings

List of Custom Messages to be Displayed

28 31 00 1.5.G 3 With shop drawings

Sequence of Operation Matrix

28 31 00 1.5.H 3 With shop drawings

List of Names and Addresses of the NICET Certified

Technicians & Copy of the NICET Certifications

28 31 00 1.5.I

Within 30 days of

NTP

Schedule of Material Submittals, MAR 05 (SAF/AQCP) / PREVIOUS FORM IS OBSOLETE

File details come from the government source that posted it. Updated .