This monthly summary report describes operations and maintenance activities for aerial targets and range instrumentation systems. It provides details on full-scale and sub-scale aerial target missions at Tyndall AFB and Holloman AFB, including sorties flown, maintenance issues, quality inspections, and facilities work requests. Key metrics like abort rates, repeat discrepancies, and maintenance data are also included. The report is intended to update the prime contractor, PAE, and the Air Force on contract performance for aerial targets and range systems at the two bases under contract number FA4890-15-C-0018.
View the file
Other files for this federal contract opportunity
Show all 50
Aerial Targets III FY23 has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AERIAL TARGETS MONTHLY SUMMARY MAY 2020
Unclassified Page 1 of 42 Distribution: A
Aerial Targets Monthly Contract Summary Report – CDRL A001
Contract Number FA4890-15-C-0018
1 – 31 May 2020
Prepared for:
Acquisition Management and Integration Center
Langley AFB, Virginia
Prepared by:
PAE Aviation and Technical Services, LLC
1001 Florida Avenue
Tyndall AFB, Florida
David Olson
Program Manager
Aerial Targets Program
UNCLASSIFIED
Distribution Limitation: A
Unclassified Page 2 of 42
TABLE OF CONTENTS
Tab 1A – FULL-SCALE AERIAL TARGETS – TYNDALL AFB, FL
Tab 1B – FULL-SCALE AERIAL TARGETS – HOLLOMAN AFB, NM
Tab 2 – SUBSCALE AERIAL TARGETS – TYNDALL AFB, FL
Tab 3 – RANGE INSTRUMENTATION SYSTEM (RIS) O&M
Tab 4 – MAINTENANCE DATA SYSTEM ANALYSIS (MDSA) METRICS
Tab 5 – TECHNICAL REPORT STATUS
Tab 6 – QUALITY CONTROL (QC) SUMMARY REPORT
Tab 7 – RIS MAINTENANCE ANALYSIS REQUESTS
Tab 8 – FACILITIES OPEN WORK REQUESTS
Tab 9 – CONTRACTOR PROGRAM MANAGEMENT CONCERNS
Unclassified Page 3 of 42
TAB 1A – FULL-SCALE AERIAL TARGETS – TYNDALL AFB, FL
1. SORTIES SCHEDULED:
Note: Off-station sorties reported in this summary are credited to the location that possessed the aircraft, regardless of who launched or recovered the aircraft.
2. MISSIONS FLOWN:
QF-16 NULLO:
Mission Symbol Mission Project Supported # Missions FYTD
O5ZZ JATM JATM 1
All O5ZZ 1
Sub Total 1 11
QF-16 MANNED:
Mission Symbol Mission Project Supported # Missions
O3ZZ XC O&M 1
All O3ZZ 1 3
O5ZZ JATM Chase JATM 1
O5ZZ JATM JATM 10
All O5ZZ 11 130
O6ZZ CT O&M 24
O6ZZ XC O&M 7
All O6ZZ 31 334
All O8ZZ 0 5
Sub Total 43 472
Grand Total 44 483
3. TOTAL HOURS FLOWN:
Mission Symbol Hours FYTD
O5ZZ 0.8 7.5
Sub Total 0.8 7.5
QF-16 MAY 20 FYTD
Scheduled 52 569
Canceled 8 80
Successful Flown 44 481
Ground Aborts 2 43
Air Aborts 0 2
Total Flown 44 483
Unclassified Page 4 of 42 Distribution: A
QF-16 MANNED:
Hours FYTD
O3ZZ 1.5 4.7
O5ZZ 21.9 208.1
O6ZZ 44.2 432.6
O8ZZ 0.0 6.7
Sub Total 67.6 652.1
Grand Total 68.4 659.6
4. MISSIONS CANCELED:
Date
MDS
AF#
Msn
Sym
Mission
Reason
13 May QF-16C 26 O5ZZ Chase Project
13 May QF-16C 24 O5ZZ JATM HOT Project
14 May QF-16C 26 O5ZZ Chase Project
14 May QF-16C 24 O5ZZ JATM HOT Project
15 May QF-16C 26 O5ZZ Chase Project
15 May QF-16C 24 O5ZZ JATM HOT Project
26 May QF-16C 53 O6ZZ FCS Weather
26 May QF-16C 48 O6ZZ FCS Weather
5. ABORTS – GROUND AND AIR:
Date Type
Abort
MDS AF
Msn
Sym
Mission Reason
11 May GAB QF-16C 22 O5ZZ JATM Aircraft battery fail
21 May GAB QF-16C 26 O6ZZ CT Aircraft battery fail
6. MAINTENANCE AND LOGISTICS PROBLEMS:
a. Maintenance:
(1) QF-16:
(a) AF056 Awaiting SAFE
(b) AF060 Awaiting SAFE
(c) AF062 Awaiting SAFE
(d) AF068 Awaiting SAFE
(2) AGE/Support Vehicles:
(a) QF-16 AGE and Support/Test Equipment
1. Procurement of AGE equipment, support/test equipment is continuing.
Unclassified Page 5 of 42 Distribution: A
(b) Stock listed and commercially procured AGE maintenance equipment and tool purchasing in work.
b. Logistics:
(1) Long lead-time (MICAP) on F-16A components is negatively affecting the ability to generate aircraft.
(2) Post Hurricane Michael supply needs are being met via Tyndall AFB and Eglin AFB.
Delays in processing/receiving parts are continual.
7. WASHES:
a. Washes Accomplished in May 2020:
WEEK ENDING AF#
30 Day: 8 May 024, 057, 030, 050, 054
15 May 026, 035, 040, 053, 051, 057
22 May 022, 021, 032, 027
29 May 038, 042, 048, 052, 029, 047, 062
a. Washes Not Accomplished & Reasons:
AF023 – In fuel barn for fuel cell leak
AF030 – De-man in work
AF055 – Transferred to Holloman
c. Wash Schedule for June 2020:
WEEK ENDING AF#
30 Day: 5 June 024, 050, 054
12 June 023, 056, 031, 030, 060
19 June 026, 035, 051, 053, 040
26 June 022, 021, 032, 027, 038, 042, 062
30 June 029, 048, 047, 052
8. REPEAT/RECURRING DISCREPANCIES:
Date MDS AF# R/R Discrepancy Corrective Action
None
9. RECOMMENDATIONS: Negative this report period.
10. SPECIAL PROJECTS/SPECIAL INTEREST: Negative this report period.
Unclassified Page 6 of 42
TAB 1B – FULL-SCALE AERIAL TARGETS – HOLLOMAN AFB, NM
Note: Off-station sorties reported in this monthly summary are credited to the location that possessed the aircraft, regardless of who launched or recovered the aircraft.
Mission Symbol Mission Project Supported # Missions FYTD
All O5ZZ
Sub Total 0
QF-16 MANNED:
Mission Symbol Mission Project Supported # Missions FYTD
All O3ZZ 8
All O4ZZ 0
O5ZZ
All O5ZZ 45
O6ZZ C/T Training 12
O6ZZ WITS Training 3
All O6ZZ 15 136
All O8ZZ 1
Grand Total 15 190
05ZZ 0.0 0.0
NULLO sub Total
QF-16 MANNED:
Hours FYTD
O3ZZ 1.8 14.0
O4ZZ 0.0 0.0
O5ZZ 0.0 73.5
O6ZZ 21.4 202.9
QF-16 MAY 20 FYTD
Scheduled 18 209
Canceled 3 18
Successful Flown 14 190
Ground Aborts 3 16
Air Aborts 1 1
Total Flown 15 191
Unclassified Page 7 of 42 Distribution: A
O8ZZ 0.0 1.3
Sub Total 21.4 291.7
Grand Total 21.4 291.7
Date MDS AF# Msn
Sym
Mission Reason
15 May QF-16C 049 O6ZZ WITS Ops
21 May QF-16C 044 O6ZZ CT HHQ
21 May QF-16C 045 O6ZZ CT HHQ
Abort
MDS AF# Msn
Sym
Mission Reason
1 May GAB QF-16C 044 O6ZZ WITS Flight Controls
11 May GAB QF-16C 049 O6ZZ CT Engine Warning light
15 May AAB QF-16C 049 O6ZZ WITS Engine Warning light
20 May GAB QF-16C 049 O6ZZ WITS Engine Warning light
a. Maintenance: We were without AF028 the entire month due to replacement engine needed. It’s been ordered and shipment is in work. Also, the Engine Warning Light experienced by AF049 was extremely difficult to diagnose the cause and repair the aircraft due to difficulty duplicating the problem until just prior to replacement of the Engine
Warning Control Unit. The aircraft flew code 1 on 29 May 2020
b. Logistics: New Items: Negative this report period.
7. WASHES:
Washes Accomplished: AF044, AF055
Washes Not Accomplished & Reasons: AF014 – NULLO conversion in-work
AF028 – F-1 Cavity Fuel Leak
Date MDS AF# R/R Discrepancy Corrective Action
15 May
QF-16C
Engine light came on steady, then flickering
R2 5 mod/10 function caution light assembly
20 May QF-16C 049 Engine Warning Lite comes steady R2 Engine warning control unit
Unclassified Page 8 of 42
9. RECOMMENDATIONS: Negative this report period.
10. SPECIAL PROJECTS/SPECIAL INTEREST: Negative this report period.
TAB 2 – SUBSCALE AERIAL TARGETS – TYNDALL AFB, FL
Note: Off-station sorties reported in this summary are credited to the location that possessed the aircraft, regardless of who launched or recovered the aircraft.
BQM-167A
Mission Symbol Mission Project Supported #
Missions
FYTD
O5ZZ F-15 OFP/ CTF F-15 OFP/ CTF 0 2
O5ZZ APS TEST APS TEST 0 1
O5ZZ F16 Cruise Missile
Defense Test
F16 Cruise Missile
Defense Test
0 1
O5ZZ AMRAAM SIP AMRAAM SIP 2 4
O5ZZ AIM 9X AIM 9X 0 5
O5ZZ AMR PHS4 AMR PHS4 0 1
O5ZZ WSEP WSEP 0 27
Total 2 41
BQM-167A MAY 20 FYTD
Scheduled 4 72
Canceled 2 30
Successful Flown 2 41
Ground Aborts 0 3
Air Aborts 0 0
Total Flown 2 41
Unclassified Page 9 of 42
BQM-167A
O5ZZ 2.0 32.4
Total 2.0 32.4
Date
MDS
Tail #
Msn Sym
Mission
Reason
6 May BQM167A O5ZZ AMRAAM SIP Project
6 May BQM167A O5ZZ AMRAAM SIP Project
Abort
MDS Tail# Msn
Sym
Mission Reason
a. Hurricane damage to building 256’s roof continues to impact Mx activity and available storage space due to the amount of water intrusion into the hangar. Maintenance time is lost to cleaning it up after any rain. Temporary Mx facilities have been erected, but are awaiting a floor covering change-out before they can be moved into.
b. Minor adjustments to the established Forward Supply point continue, but there are presently no new or major impacts to target generation.
c. The three temporary facilities for SSAT Mx and the two for the chute shop have been identified as “Not safe for Mx personnel during a 5 MILE LIGHTNING LIGHT” and will require evacuation during this entire period. PAE has engaged the 53 WEG leadership for possible alternatives that would negate the need to leave the facilities. Additionally, we have asked for a location to be identified for Mx to go to during this time.
d. We have been notified that all 5 tents (chute shop x 2 and SSAT Mx x 3) will have to be moved. Locations for them are still in discussion.
7. CORROSION CONTROL INSPECTION:
a. Launch Pad Corrosion Control Maintenance: Routine corrosion control is being accomplished on all applicable support equipment.
Unclassified Page 10 of 42 Distribution: A
b. Launch Rail Gantry systems 1, 2, 5, & 6 are showing signs of severe corrosion (they were installed in 1975). Presently, they are all serviceable. However, their replacements should be programmed / considered in the near future. NOTE: Gantries on rails 3 & 4 are newer and will not require replacement any time soon.
Date MDS Tail# R/R Discrepancy Corrective Action
9. RECOMMENDATIONS: None
10. SPECIAL PROJECTS: None
Unclassified Page 11 of 42 Distribution: A
TAB 3 – RANGE INSTRUMENTATION SYSTEM (RIS) O&M
1. Tellabs Switch and Data/Comm. Operational Availability:
Tellabs Switch: 100% Available
Data/Comm. Circuits: 100% Available
2. Mission Availability:
GRDCS: 100% Available
RCS: 100% Available
Access Net: 100% Available
Mission Video: 100% Available
TPS-75 Radar: Scheduled Available Non-Charge Not Available
Missions 10 9 1 0
Hours 31.00 27.00 4.00 0
Overall Availability: 100% Available ((Available + Non-Charge)/Scheduled)
0%
20%
40%
60%
80%
100%
Tellabs Switch Data/Comm
May 100% 100%
12 month avg 100% 100%
0% 10% 20% 30% 40% 50% 60% 70% 80% 90%
100%
GRDCS RCS AccessNet TPS-75 Mission Video
May 100% 100% 100% 100.0% 100.0%
12 month avg 100% 100% 100% 100.0% 100%
Unclassified Page 12 of 42
3. Summary of Mission Maintenance Actions:
a. 11 May 2020: Performed annual inspection on DLS S/N 114 (ISC Path 2).
b. 13 May 2020: Received from PMEL and installed RF Sensor in 915 DTS S/N 002.
Performed full self-calibration on unit.
c. 14 May 2020: Received DLS S/N 124 from the Navy after AEGIS use. Performed full bench check and reconfigured unit for field use as a DLS spare.
d. 26 May 2020: Performed calibration of Legacy DLS Test Set SN 004.
4. RIS Scheduled Maintenance Summary:
a. GRDCS:
1) Due within 45 Days:
Monthly Console Checks, by 30 June 2020
2) Due within 90 Days:
Data Link Subsystem Annual Checks:
SITE DATE DUE S/N Test Type
RWEr 09 Jun 2020 031 3 Month
SUBW 09 Jun 2020 032 3 Month
D1C 17 Jun 2020 024 Annual
SUBE 18 Jun 2020 025 9 Month
RWSr 30 Jun 2020 019 6 Month
A10 30 Jun 2020 028 6 Month
DEPOT 09 Jun 2020 054 3 Month
B226 15 Jun 2020 135 Annual
Unclassified Page 13 of 42
b. TPS-75 Radar: Accomplished this month and due within 45 Days.
JOB Completed or due from3/30/2020 until 5/29/2020 JST REOCCUR Next Due EQUIP #
/0
/2
/0
/2
/0
/2
/0
/2
/0
/2
/0
/2
/1
/2
/1
/2
/1
/2
/1
/2
/1
/2
/1
/2
/1
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/0
/2
/0
/2
/0
/2
/0
/2
/0
/2
/0
/2
/0
/2
/1
/2
/1
/2
/1
/2
/1
/2
/1
/2
/1
/2
/1
/2
/1
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/3
/2
/0
/2
/0
/2
/0
/2
ANTENNA TIEDOWN STRAPS AND JACKPAD INSPECTION 24 DAILY RE035 0 1 1 1 1 0 1 1 1 1 1 1 1 1 0 0 0 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 35E4-178-1 TABLE 2-1
DAILY PERFORMANCE INSPECTION 24 DAILY RE035 0 1 1 1 1 0 1 1 1 1 1 1 1 1 0 0 0 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 31P3-2TPS75-6WC-1
UPX 37 DAILY SYSTEM CHECKS - SER # A0109 266 DAILY REA09 0 1 1 1 1 0 1 1 1 1 1 1 1 1 0 0 0 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2UPX37-1 TBL 4-1
UPX 37 DAILY SYSTEM CHECKS - SER # C0126 266 DAILY REA26 2UPX37-1 TBL 4-1
3N1 DAILY PERFORMANCE CHECK 301 DAILY C60A3 0 1 1 1 1 0 1 1 1 1 1 1 1 1 0 0 0 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 35E4-177-1 TABLE 2-1
2N1 DAILY PERFORMANCE CHECK 326 DAILY C84B2 0 1 1 1 1 0 1 1 1 1 1 1 1 1 1 0 0 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 35E4-178-1 TABLE 2-1
DISPLAY CONSOLE TURN ON/OFF 1301 DAILY RE035 0 1 1 1 1 0 1 1 1 1 1 1 1 1 1 0 0 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 31P1-2UYQ27-26WC-1
UPA 59 DAILY PREVENTATIVE MAINTENANCE 1308 DAILY RE035 0 1 1 1 1 0 1 1 1 1 1 1 1 1 0 0 0 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 31P1-2UPA59-1-1 & 2
WEATHER/ECM PERFORMANCE ROUTINE 2 7 DAY 6/3/20 RE035 1 1 1 1 0 0 0 0 0 31P3-2TPS75-6WC-1
RADAR/SIF SYSTEM TEST PERFORMANCE 50 7 DAY 6/2/20 RE035 1 1 1 1 0 0 0 0 0 31P3-2TPS75-6WC-1
I-F RECEIVER PERFORMANCE ROUTINE 51 7 DAY 6/3/20 RE035 1 1 1 1 0 0 0 0 0 31P3-2TPS75-6WC-1
HEIGHT PERFORMANCE ROUTINE 73 7 DAY 6/2/20 RE035 1 1 1 1 0 0 0 0 0 31P3-2TPS75-6WC-1
CLUTTER MAPPING PERFORMANCE ROUTINE 74 7 DAY 6/5/20 RE035 1 1 1 1 0 0 0 0 0 31P3-2TPS75-6WC-1
COMMUNICATIONS PERFORMANCE ROUTINE 273 7 DAY 6/2/20 RE035 1 1 1 1 0 0 0 0 0 31P3-2TPS75-6WC-1
POWER SUPPLY TEST PERFORMANCE ROUTINE 273 7 DAY 6/2/20 RE035 1 1 1 1 0 0 0 0 0 31P3-2TPS75-6WC-1
DISPLAY CONSOLE WEEKLY INSPECTION 1303 7 DAY 6/5/20 RE035 1 1 1 1 0 0 0 0 0 31P1-2UYQ27-26WC-1
ANTENNA/RECEIVER INTERFACE TEST PERFORMANCE ROUTINE 550 14 DAY 6/11/20 RE035 1 1 0 0 31P3-2TPS75-6WC-1
SYSTEM ORIENTATION PERFORMANCE CHECK 993 14 DAY 6/9/20 RE035 1 1 0 0 31P3-2TPS75-6WC-1
AFRADES HEIGHT EVALUATION 999 14 DAY 6/9/20 RE035 1 1 0 0 31P3-2TPS75-6WC-1
AFRADES BEACON PERFORMANCE 1038 14 DAY 6/9/20 RE035 1 1 0 0 31P3-2TPS75-6WC-1
AFRADES CLUTTER ANALYSIS 1041 14 DAY 6/9/20 RE035 1 1 0 0 31P3-2TPS75-6WC-1
AUTO SEQUENCER TEST 1207 14 DAY 6/9/20 RE035 1 1 0 0 31P3-2TPS75-6WC-1
HEAT EXCHANGER SERVICING 1270 14 DAY 6/1/20 RE035 1 1 0 0 0 35E4-177-1 TABLE 2-1
SHELTER CLEANING AND INSPECTION SERVICING 1271 14 DAY 6/4/20 RE035 1 1 0 0 35E4-177-1 TABLE 2-1
COMPRESSOR DEHYDRATOR ON/OFF RATIOS 304 28 DAY 6/15/20 RE035 1 0 31P3-2TPS75-6WC-1
FREQ GENERATOR COHO REF OUTPUT CHECK 1241 28 DAY 6/16/20 RE035 1 0 31P3-2TPS75-6WC-1
FREQ GENERATOR IF TEST TARGET AMPLITUDE CHECK 1245 28 DAY 6/16/20 RE035 1 0 31P3-2TPS75-6WC-1
ANTENNA PEDESTAL AND LEVELING JACK INSPECTION 1250 28 DAY 6/2/20 RE035 1 0 31P3-2TPS75-6WC-1
RF AND SLIP RING TEST 1253 28 DAY 6/9/20 RE035 1 0 31P3-2TPS75-6WC-1
MDS/FAR TEST 1254 28 DAY 6/9/20 RE035 1 0 31P3-2TPS75-6WC-1
AFRADES TILT SENSOR PERFORMANCE 1255 28 DAY 6/9/20 RE035 1 0 31P3-2TPS75-6WC-1
ANTENNA ASSEMBLY CLEANING AND INSPECTION SERVICING 1272 28 DAY 6/18/20 RE035 1 0 31P3-2TPS75-6WC-1
0 = Job Forecast
/ = Partially C/W
1 = C/W
Unclassified Page 14 of 42
SHELTER CORROSION CONTROL INSPECTION AND SERVICING 1273 28 DAY 6/23/20 RE035 1 1 31P3-2TPS75-6WC-1
ANTENNA CORROSION CONTROL INSPECTION AND SERVICING 1274 28 DAY 6/17/20 RE035 1 0 31P3-2TPS75-6WC-1
ANTENNA POWER SUPPLY ENCLOSURE AIR FILTER CLEANING 1274 28 DAY 6/17/20 RE035 1 0 31P3-2TPS75-6WC-1
COMPRESSOR- DEHYDRATOR ASSEMBLY RELIEF VALVE SERVICING 1276 28 DAY 6/2/20 RE035 1 0 31P3-2TPS75-6WC-1
ANTENNA BULL GEAR LUBRICATION 1279 28 DAY 6/25/20 RE035 1 0 31P3-2TPS75-6WC-1
ANTENNA DRIVE MOTOR GEARBOX OIL LEVEL CHECK 1280 28 DAY 6/9/20 RE035 1 0 31P3-2TPS75-6WC-1
TUSK ASSEMBLY, JACKSCREW, AND ANTENNA YOKE LUBRICATION 1281 28 DAY 6/25/20 RE035 1 0 31P3-2TPS75-6WC-1
DISPLAY CONSOLE INSPECTION AND CLEANING 1304 28 DAY 6/12/20 RE035 1 0 31P3-2TPS75-6WC-1
3N1 MONTHLY PERFORMANCE CHECK 323 MONTHLY 6/3/20 C60A3 1 0 35E4-177-1 TABLE 2-1
2N1 MONTHLY PERFORMANCE CHECK 329 MONTHLY 6/3/20 C84B2 1 0 35E4-178-1 TABLE 2-1
UPX 37 QUARTERLY INSPECTION - SER # A0109 283 84 DAY 6/25/20 REA09 0 2UPX37-1 TBL 4-1
UPX 37 QUARTERLY INSPECTION - SER # C0126 283 84 DAY 6/17/20 REA26 0 2UPX37-1 TBL 4-1
TRANSMITTER OIL BREAKDOWN TEST & FILAMENT INTERRUPT CHECK PROCEDURE 1256 84 DAY 6/23/20 RE035 0 31P3-2TPS75-6WC-1
STORAGE TWYSTRON PUMP DOWN 1257 84 DAY 6/17/20 RE035 0 31P3-2TPS75-6WC-1
MODIFIED BEARING LUBRICATION 1282 84 DAY 8/24/20 RE035 1 31P3-2TPS75-6WC-1
ANTENNA LEG ASSEMBLY INSPECTION 1283 84 DAY 6/22/20 RE035 0 31P3-2TPS75-6WC-1
PROCESSOR RACK INSPECTION AND CLEANING 1285 84 DAY 6/25/20 RE035 0 31P3-2TPS75-6WC-1
MODULAR INTERFACE GROUP INSPECTION AND CLEANING 1289 84 DAY 6/19/20 RE035 0 31P3-2TPS75-6WC-1
UPX 37 SEMIANNUAL INSPECTION - SER # A0109 294 168 DAY 6/26/20 REA09 0 2UPX37-1 TBL 4-1
UPX 37 SEMIANNUAL INSPECTION - SER # C0126 294 168 DAY 6/18/20 REA26 0 2UPX37-1 TBL 4-1
TRANSMITTER LIQUID COOLANT SERVICING 1290 168 DAY 9/8/20 RE035 31P3-2TPS75-6WC-1
PPI CIRCUIT CARD INSPECTION AND CLEANING 1291 168 DAY 7/27/20 RE035 31P3-2TPS75-6WC-1
CONTROL MONITOR INSPECTION AND CLEANING 1292 168 DAY 7/15/20 RE035 31P3-2TPS75-6WC-1
ANTENNA AND SHELTER JACKS LUBRICATION 1293 168 DAY 7/1/20 RE035 31P3-2TPS75-6WC-1
UPA 59 PREVENTATIVE MAINTENANCE 1309 168 DAY 6/23/20 RE035 0 31P1-2UPA59-1-1 & 2
ANTENNA DRIVE MOTOR GEARBOX SERVICE 1294 336 DAY 7/29/20 RE035 31P3-2TPS75-6WC-1
PROCESSOR RACK AND CIRCUIT CARD INSPECTION AND CLEANING 1295 336 DAY 7/29/20 RE035 31P3-2TPS75-6WC-1
INTERROGATOR CIRCUIT CARD INSPECTION AND CLEANING 1297 336 DAY 7/29/20 RE035 31P3-2TPS75-6WC-1
DESICCANT CARTRIDGE REPLACEMENT 1298 336 DAY 1/14/21 RE035 31P3-2TPS75-6WC-1
CONTROL MONITOR INSPECTION, CLEANING, AND LUBE 1299 336 DAY 7/13/20 RE035 31P3-2TPS75-6WC-1
HIGH VOLTAGE INSULATED GLOVES TEST SET #1 367 365 DAY 5/7/20 RE035 0 / AFI 91-203, 812.8
HIGH VOLTAGE INSULATED GLOVES TEST SET #2 396 365 DAY 5/4/21 RE035 / / / / / / / / / / / / / / / / / / / / / / 1 AFI 91-203, 812.8
ANNUAL HISTORICAL RECORDS REVIEW 1320 365 DAY 2/6/21 RE035 00-20-1 PARA 10.7.4
ANNUAL FACILITY GROUNDS INSPECTION 1322 365 DAY 12/14/20 RE035
TX HOIST 1323 365 DAY 12/9/20 RE035 31P3-2TPS75-6 Chpt 2 Sec 1
ANT & SHELTER LIFT HARDWARE INSPECTION BY NDI/ TX HOIST 68 365 DAY 12/30/00 RE035 31P3-2TPS75-6 Chpt 2 Sec 1
ANTENNA TIEDOWN STRAPS INSPECT AND REPLACE ALL 1324 720 DAY 1/28/21 RE035 31P3-2TPS75-6
INSPECT AND REPLACE ALL HYDRAULIC HOSES 1325 60 MONTH 06/06/23 RE035 31P3-2TPS75-6
MIL-HDBK-419A PARA 2.3.1, 31-
10-24 Appx B
5. Maintenance and Logistics Problems:
With the dissolution of the sole repair vendor for the proprietary DLS Receiver/Transmitter units, the current cache of four spare units are all that are available. Some DLSr units have been delivered, and are being used on a limited basis. The remaining DLSr delivery date is a moving target, with an anticipated delivery of June 2020.
a. Top Five Report:
b. Long Lead Report:
6. Gulf Range Tower Conditions:
a. Tower for Site RWN:
Hurricane Michael brought down tower containing this antenna.
Temporary tower installed and working well.
Contracts were awarded September 2019 for replacement of this tower.
Temporary tower moved in order for permanent replacement tower to be erected in the original location. Survey was completed, and temporary tower is running at new location.
b. Tower for Site RWW:
Hurricane Michael brought down tower containing this antenna.
Temporary tower installed and working well.
Contracts were awarded September 2019 month for replacement of this tower.
Temporary tower moved in order for permanent replacement tower to be erected in the original location. Survey was completed, and temporary tower is running at new location.
c. Tower for Site APPL:
Hurricane Michael brought down tower containing this antenna.
d. All other towers fully functional.
Top 5 Parts Ordered
NSN Part Number Nomenclature End Item Remarks
4210-00-595-4085 D737907 BRACKETS SHOPUSE Est Due 5 Jun 20
5965-01-593-8311 40709-02 EAR CUSHIONS GRDCS Rec'd 21 May 20
Only two parts were ordered during this reporting period.
Top 5 Parts With Longest Lead Time
Date Ordered NSN Part Number Nomenclature QTY End Item Remarks
19-Jun-18 8010-00-490-7650 MIL-L-81352 LACQUER 1 RADAR Est Due 9 Nov 20
15-Jan-19 7920-00-823-9773 AA1432 TOWEL UTILITY 4 SHOPUSE Est Due 8 Jul 20
16-Oct-19 6625-01-571-1592 N9912A-104/230 SIGNAL ANALYZER 1 EQUIPMENT Est Due 18 Feb 21
10-Dec-19 6625-01-344-9277 SMR27 SIGNAL GENERATOR 2 EQUIPMENT Est Due 31 Dec 20
16-Mar-20 5998-01-326-8767 3D56988G01 CCA 1 RADAR Est Due 13 Jun 20
Unclassified Page 16 of 42 Distribution: A
7. Wendover Status:
a. Building 625 Control Site:
PAE continues to work infrastructure requirements per TSS requests for both a consolidated Wendover only operation and the requirements for a split configuration that would have control at Wendover and drone launches at Dugway. The 388th's contractor
JT3 will provide the WEG an estimate for their support to finish their infrastructure upgrade for the host communications system.
PAE provided locations and quantities for NIPR and SIPR drops within building 625 to aid JT3 with their estimates. Cable and jacks for phones and NIPR computers are installed between the communications room and each location within the building so only the range infrastructure remains to be completed. The TSS is working procurement of the computers and phone instruments.
Based on the consolidated versus split operations plan, the tower needed at building 625 will be new or come from the current Wig Mountain site. The tower at 625 will support antennas for GRDCS, radios and GPS timing. The fastest and most versatile path is to purchase and install a new tower onto the newly built tower base already in place at
Wendover; a new tower would provide increased height (better coverage) at a cost of
~$20K. For either solution, additional RF cable, mounting clamps, etc. must be purchased for the move; a list of those parts was provided to the TSS, ~$6.6K.
GRDCS “New Tech” hardware and software were installed in the Wendover control site; however, the software must be updated to the newest revision in order to become operational.
On 29 April 2019, UTTR 388th personnel reported a water pipe had burst inside the wall of the mechanical room in control site building 625. The water affected several rooms including the console room and server/communications rooms. Per a report from a SPO representative from Hill, none of the WEG owned equipment was damaged and the only required repair for the operations areas is new floor coverings. The break room received more significant damage, primarily to cabinetry and carpet.
b. Launch Pad:
Compressors and power supplies must be purchased for the rails. The 82nd RAs were working this in 2018; there was a contracting hiccup, so funding short stopped the purchase.
Gantries and hoists must be purchased for the launch pad as well as a contract let to install them. PAE completed a design; the narrative for the SOW for the construction must be written before the task can go out for bids.
PAE is developing parts lists for the installation of the rails, power supplies, compressors, grounding, communications, connections for generator, etc.
Fiber equipment must be purchased and installed to provide connectivity from building
625 to the LAMS, and in turn from the LAMS to the launch pad. Much of the hardware from Dugway will be reused when maintenance activities and launch operations move from Dugway; however, several additional items will be needed due to the longer fiber cable runs.
Work continues with environmental approval contractor for the launch and maintenance areas.
Unclassified Page 17 of 42 Distribution: A
c. LAMS Maintenance Shelter:
PAE is working a requirements document to install electrical, grounding, lightning protection, etc.
PAE is developing parts lists for the installation of a compressor, stands to mount items like fire extinguishers, eyewash, AED, etc.
PAE is working a requirements document for a secure storage area within the LAMS.
The LAMS itself was erected; however, it requires repair due to wind damage. The
WEG is working the repair effort.
d. Wendover GRDCS Sites:
The TSS is working lease efforts for the I-80 GRDCS site. This is the single most critical RF point needed to use the Wendover control whether launching from Dugway or Wendover. Site H97 is going through the environmental process. It would also be very helpful for Dugway operations with Wendover control, but it really becomes critical when launch operations move to Wendover. PAE is designing an inclusive site platform for H97.
8. GRDCS and RCS Operating Hours:
9. GRDCS and RCS Accounts Status:
a. GRDCS Accounts:
The GRDCS computers are accessed by user groups rather than by individual accounts. The users are trained for, and only granted access to, the level required to perform their assigned tasks. The three user groups and their level of access are depicted in the following chart.
Mission Support Maintenance Programming &
Engineering
Administration
GRDCS 54.27 15.37 1.42 3.22
RCS 266.00 31.00 34.00 49.00
H o u rs
GRDCS (Operations) CDT (Maintenance) ROOT (Administration)
Hours 68.54 2.52 3.22
GRDCS User Accounts
Unclassified Page 18 of 42 Distribution: A
b. RCS Accounts:
The RCS computers are accessed by user groups rather than by individual accounts. The users are trained for and only granted access to the level required to perform their assigned tasks. The five user groups and their level of access are depicted in the following chart.
10. Engineering and Systems Programming Tasks:
a. Short Title: Testing and evaluation of the maximum GRDCS participant capability.
Summary: Due to the additional GRDCS hardware/software implementation of SIR 451
“Integration of NDI-AIU C-Band Beacon data into GRDCS and RCS
External Track Data” with development version 55, test flights are being supported to verify the maximum GRDCS participant capability.
Date Initiated: 24 April 2009
Completion Date (Estimated): TBD, depending on availability of mission(s).
Current Status: 85% complete.
Problems anticipated or encountered: None.
b. Short Title: Test TM connectivity with Bldg. 223 in order to evaluate the external
NDI-AIU C-Band Beacon data with Safety.
Summary: Due to the additional GRDCS hardware/software implementation of SIR 451
“Integration of NDI-AIU C-Band Beacon data into GRDCS and RCS
External Track Data” with development version 55, a connectivity test with
TM Bldg 223 is still pending to evaluate the data into GRDCS and RCS.
Date Initiated: 13 July 2009
Completion Date (Estimated): TBD, depending on TM shop and testing results.
Current Status: 0% complete.
Problems anticipated or encountered:
First test on 13 July 2009 was not successful. Bldg. 223 personnel could not start the program. More work on their side is required.
83rd 82nd ROOT USAF_Administr ator
Wetstone MSCT
Hours 0.00 17.50 19.00 38.00 416.00 416.00
RCS User Accounts
Unclassified Page 19 of 42 Distribution: A
c. Short Title: Software installation (Release Candidates 3 & 4) and demonstration of SIRs of GRDCS Software/Hardware Version 61.0 – 61.0.7
Summary: Testing is complete.
Date Initiated: 21 August 2018
Completion Date: 04 December 2019
Current Status: Sufficiency of Test Review (SOTR) for fielding authorization was provided on 04 Mar 2020. SOTR pending field changes at this time. Fielding scheduled for the week of June 15th, 2020.
Problems anticipated or encountered: None at this time.
d. Short Title: User software (increment-13, based on v60.4) installation for the QF-16 DR2
Hardware Changes (SIR 843).
Summary: In process of supporting ground and test flights for the QF-16 DR2 Hardware
Changes with Autopilot v1.7 software.
Date Initiated: 29 June 2018
Completion Date (Estimated): TBD
Current Status: Flight testing is complete at Tyndall and is presently taking place at
Holloman. SIR 843 scheduled to be included in v62 software upgrade.
e. Short Title: Software installation of GRDCS Software V62.0 (29Mar19).
Summary: In process of supporting DT testing for v62.0 for the software upgrade.
Date Initiated: 29 March 2019
Completion Date (Estimated): TBD
Current Status: Demo Phase; Start date 28 Feb 2019 with video (SIR844) and .sml file
(SIR878). Continued on 29 May 19, with SIR 739, 822, 874, 849, 877, and 674.
Supported DT phase at Eglin 21-22 January 2020, 18-19 & 26 February 2020.
11. Special Projects:
a. In process of enhancing locally developed ‘safe flight script’ to handle QF-16 telemetry during the different phases of the safe flight profile (10% complete).
b. Supporting Wendover system evaluation as a first look of the new hardware (console and computer) and software to include local RF environment. (Ongoing effort at this time, no
ETA available yet).
12. ATIS Mission Support (Over-the-Horizon Airborne Relays using platform aircraft):
a. None for this reporting period.
Unclassified Page 20 of 42 Distribution: A
TAB 4 – MAINTENANCE DATA SYSTEM ANALYSIS (MDSA)
METRICS
1. MDSA Metrics:
a. Abort Rate: SDS Criteria FSAT/SSAT < 12%
FSAT = 10.2% (1 AAB + 5 GAB with 59 sorties flown and 0 chargeable GAB lines)
((1 / 59) + (5 / (59 + 0))) x100)
FLCS self-test would not start (HAFB)
Aircraft battery fail
Engine warning light / Master caution light (HAFB)
Engine light (AAB) (HAFB)
Engine warning light (HAFB)
Aircraft battery fail
SSAT = 0.0% (0 AAB + 0 GAB with 2 sorties flown and 0 GAB lines)
((0 / 2) + (0 / (2 + 0))) x100)
b. Repeat/Recur Rate: SDS Criteria FSAT/SSAT < 7%
FSAT = 12.5% (2 Repeat + 0 Recur with 16 PRDs) ((2 / 16) x 100)
SSAT = 0.0% (0 Repeat & 0 Recur with 0 PRDs) ((0 / 0) x 100)
c. Cannibalization Rate: 16.4% (10 Canns with 61 Sorties Flown) ((10 / 61) x 100)
d. Data Integrity Error Rate: SDS Criteria - 98% of correctable errors corrected
100.0% (26 Errors with 1 Uncorrectable and 25 Corrected) (25 / (26 - 1)) (2,575
DDRs checked)
e. Break Rate = 9.8% (6 Code 3s with 61 Sorties Flown) ((6 / 61) x 100)
f. Primary Aerospace Vehicle Authorized (PAA) vs. Possessed (PP) Rate:
FSAT = 100.0% (34 assigned with 34 possessed, 50 baseline and 0 CLIN 4/6 inventory at EOM) ((34 / 34) x 100)
SSAT = 100.0% (46 PAA with 46 possessed and 0 CLIN4/6 inventory at EOM) ((46 /
46) x 100)
g. FSAT Mission Success Rate: SDS Criteria - 95%, Critical Standard – 98%
98.3% (70 Sorties attempted with 58 successful and 11 non-chargeable non-successful) ((58 / (70 - 11)) x 100)
h. SSAT Mission Success Rate: SDS Criteria - 95%, Critical Standard – 98%
100.0% (4 Sorties attempted with 2 successful and 2 non-chargeable non-successful)
((2 / (4 - 2)) x 100)
Unclassified Page 21 of 42
2. Maintenance and Flying Schedule Effectiveness (MSE and FSE)
a. MSE = 84.4% (768 points scheduled with 648 complied with) ((648 / 768) x 100)
b. FSE = 70.3% (61 sorties flown, with 13 sorties cancelled, 0 sortie added and 22 total
FSE deviations) (((74 - 22) / 74) x 100)) (Of the 22 chargeable deviations, 3 were attributed to maintenance.)
The main driver was 13 Cancels.
Add Lines = 0
Add Tails = 1 (1 Mx)
Cancels = 13 (2 HHQ, 1 Ops, 2 Other, 6 Project, 2 Wx)
Early T/O = 4 (2 Ops, 1 Project, 1 Range)
Late T/O = 4 (2 Mx, 1 HHQ, 1 Sympathy)
GAB Lines = 0
3. Narratives:
Ground & Air Aborts
a. FSAT – There were 3 ground aborts and 1 air abort at Holloman and 2 ground aborts at
Tyndall during May. These aborts involved 4 aircraft.
(1) For the third month in a row, one aircraft recorded 3 aborts. AF049 ground aborted twice and air aborted once, all for engine-related issues.
(a) On 11 May, it ground aborted for Engine Warning Light/Master Caution Light, corrected by replacing the RPM Gauge.
(b) On 15 May, it air aborted for Engine Light, corrected by A System Hydraulic
Warning Light On for A System Lower Pressure Switch, corrected by replacing the 5 Mod/10 Function Caution Light Assembly.
(c) On 20 May, it aborted for Engine Warning Light, corrected by replacing the
EWCU.
(d) AF049 had only recorded 2 other aborts previously – one unrelated ground abort in October 2019 and one air abort in September 2019 for Engine Caution
Light (R2 DEC). This makes it the 35th highest aborting aircraft of the 57 QF-
16s we thus far received.
(2) There were 2 ground aborts for Aircraft Battery Fail, one on AF022 at Tyndall on
11 May and one 10 days later on AF026 at Holloman. Both were corrected by replacing the battery. Neither aircraft has had a similar abort previously. This brings AF026 to a total of 7 ground aborts and 2 air aborts, just 20th in the QF-16
Unclassified Page 22 of 42 Distribution: A abort rankings. AF022 doubles that with a total of 18 ground aborts, the 4th highest of all QF-16s and 2nd highest of the active QF-16s.
(3) There were no other trends noted this month.
(4) The numerical breakouts for May were:
(a) The 6 aborts involved 2 QF-16Cs at Tyndall and 2 at Holloman.
(b) Five aborts occurred on O&M flights and 1 on a customer sorties. All were manned sorties.
(c) The weekly abort distribution was 2 on a Monday, 1 on a Wednesday, 1 on a
Thursday, and 2 on Fridays. Five aborts occurred on scheduled morning sorties and 1 an afternoon sortie.
(d) No sorties were lost to an abort.
b. SSAT – None
Date Base AF # Reason Corrective Action
FSAT
1 May HAFB 44 FLCS Did FLCS self-test x3 on engine run. CND
11 May TAFB 22 Aircraft battery fail R2 aircraft battery
11 May HAFB 49
Engine warning light/Master caution light R2 RPM gauge
15 May HAFB 49 Engine light R2 5 mod/10 function caution light assembly
20 May HAFB 49 Engine warning light R2 EWCU
21 May TAFB 26 Acft battery fail R2 aircraft battery
SSAT
TAB 5 – TECHNICAL REPORT STATUS
Negative this report period.
Unclassified Page 23 of 42 Distribution: A
TAB 6 – QUALITY CONTROL (QC) SUMMARY REPORT
1. Full-Scale - Tyndall:
a. Seventeen Quality Verification Inspections, two SI, and one KTL were accomplished.
Twenty inspections passed. There were zero failures this period.
b. Problem Area: None
c. PQDR/AIDRs: Seven this report period.
DR control # Date CAT ACFT #/Serial # Noun
FA4881-20-0023 5/19/20 AIDR QF056 780600
Leading edge flap rotary actuator has wrong serial number
FA4881-20-0024 5/19/20 AIDR
QF060 780615 Torque shafts overdue time change
FA4881-20-0025 5/19/20 AIDR QF062 780618 Landing Gear 95's missing from jacket file
FA4881-20-0026 5/19/20 AIDR QF056 780767 Torque shafts overdue time change
FA4881-20-0027 5/28/20 AIDR QF062 781788
Main engine feed line bolt not installed. Bolt found inside of ventral panel
FA4881-20-0028 5/28/20 PQDR QF056 781647 GPS Antenna Splitter
FA4881-20-0029 5/28/20 PQDR QF056 781874 VSS Telemetry Antenna
d. AFTO Form 22’s: None this report period.
e. TODO: Sixty-one technical order changes and revisions were received this period.
f. Impoundments: None this report period.
g. FOD/DOP/Lost item: None this report period
2. Full-Scale - Holloman:
a. Eight Quality Verification Inspections, thirteen Special Inspections, twenty-one audits, and four Personnel Evaluation were accomplished. Forty-six inspection/audits passed. One minor for CTK Management.
b. Problem Areas: None this report.
c. PQDRs: One this report period.
1) FA4810-20-0002 DPE Pushbutton Panel
Unclassified Page 24 of 42
d. AFTO Form 22’s: None this report period.
e. TODO: Reviewed 46 Technical Order changes/revisions.
g. FOD/DOP/Lost item: None this report period.
3. Subscale:
a. Five Quality Verification Inspections, seven special inspections, and eight personal evaluations. Nineteen inspections passed. There was one Fail this report period, consisting of
CTK management. There was one minor consisting of Forms documentation.
b. Problem Areas: None this report period.
c. PQDRs: None this report period.
d. AFTO Form 22s: None this report period.
e. TODO: Two technical order change and revision received this period.
g. DOP/Lost Item: None this report period.
4. GRDCS - Tyndall:
a. Four personal evaluations, two Quality Verification Inspections, and two special inspections were accomplished this period. Eight inspections passed. One minor consisting of hazmat overdue verification.
b. AFTO Form 22s: None this report period.
c. PQDRs: None this report period.
d. TODO: Zero technical orders change and revision this period.
e. Problem Areas: None this report period.
5. ESH - Tyndall:
Four inspections this period. One minor for overdue CDL due to short term disability.
Unclassified Page 25 of 42
a. Problem Areas: None this report period.
6. ESH - Holloman:
a. Two were accomplished this month. Zero Failed.
b. Problem Areas: None this report period.
7. Publications and Forms: No contractual impacts this period. See CDRL A009, Master
Document List.
0.7
0.8
0.9
TYN HMN SSAT RIS ESH
QA Inspection Pass Rate Mar - May 2020
Mar
April
May
Unclassified Page 26 of 42 Distribution: A
TAB 7 – RIS MAINTENANCE ANALYSIS REQUESTS
1. ELECTRO-MAGNETIC INTERFERENCE (EMI):
No EMI reported this period.
2. RIS MAINTENANCE ACTIONS:
RIS NUMBER: DISCREPANCY: ACTION TAKEN: MISSION IMPACT:
183020001 CARRY OVER:
All poles holding Antenna systems at B1801 down due to Hurricane Michael.
N/A No mission impact noted.
MAINT. AREA:
RIS
START DATE:
20181029
STOP DATE:
N/A
REPAIRED BY:
N/A
MAN HOURS:
N/A
COST:
N/A
DISCR. HOURS: EQUIPMENT MAKE: EQUIPMENT MODEL: EQUIPMENT S/N:
N/A N/A N/A N/A
Unclassified Page 27 of 42
183020002 CARRY OVER:
Runway West tower down due to Hurricane Michael.
Temporarily installed mobile DLS trailer at site.
No mission impact noted.
MAINT. AREA:
RIS
START DATE:
20181029
STOP DATE:
N/A
REPAIRED BY:
N/A
MAN HOURS:
N/A
COST:
N/A
183020003 CARRY OVER:
Runway North tower down due to Hurricane
Michael.
Temporarily installed mobile DLS trailer at site.
No mission impact noted.
MAINT. AREA:
RIS
START DATE:
20181029
STOP DATE:
N/A
REPAIRED BY:
N/A
MAN HOURS:
N/A
COST:
N/A
Unclassified Page 28 of 42 Distribution: A
RIS NUMBER: DISCREPANCY: ACTION TAKEN: MISSION IMPACT:
183020007 CARRY OVER:
ACDS Missile and Drone, Primary and Backup antenna systems down due to Hurricane Michael.
(See RIS# 183020001)
Temporarily installed ACDS
Missile Primary and Backup antennas on Tower 1802.
Temporarily installed Drone
Primary and backup antennas on Tower B1830.
No mission impact noted.
MAINT. AREA:
RIS
START DATE:
20181029
STOP DATE:
N/A
REPAIRED BY:
N/A
MAN HOURS:
N/A
COST:
N/A
183020011 CARRY OVER:
Runway west video is down due to Hurricane
Michael. (See RIS#
183020002)
N/A No mission impact noted.
MAINT. AREA:
RIS
START DATE:
20181029
STOP DATE:
N/A
REPAIRED BY:
N/A
MAN HOURS:
N/A
COST:
N/A
Unclassified Page 29 of 42
190980001 CARRY OVER:
RCS MULTI (RBZ94)
took a lightning strike.
Job opened with COMM
Focal Point (283-4896).
Put GRDCS Multi in RCS
Multi’s slot.
None
MAINT. AREA:
COMM
START DATE:
20190408
STOP DATE:
N/A
REPAIRED BY:
N/A
MAN HOURS:
N/A
COST:
N/A
DISCR. HOURS: BRAND: EQUIPMENT MODEL: EQUIPMENT S/N:
192120101 CARRY OVER:
GSM Transceiver
Communication Error during attempted Self-
Calibration.
IAW w/ T.O., checked all connections. Rebooted system, symptom persisted.
Reported to SPO, awaiting direction. SPO picked up unit for delivery to MSI for repair.
None
MAINT. AREA:
DLS
START DATE:
20190731
STOP DATE:
N/A
REPAIRED BY:
D. Holmes
MAN HOURS:
N/A
COST:
N/A
N/A MSI 915 DTS 003
Unclassified Page 30 of 42
200220001 CARRY OVER:
No receive on
WETSTONE GATR-A
radio (288.5).
Opened a remedy ticket. No mission impact noted.
MAINT. AREA:
COMM
START DATE:
20200122
STOP DATE:
N/A
REPAIRED BY:
N/A
MAN HOURS:
N/A
COST:
N/A
200220101 CARRY OVER:
60% data quality reported on DLSr at
SUBW
Performed DLSr FAT, Oscillator Calibration, and
Pulses Present tests, all tests passed except for
“PA Enable.” RMA requested from MSI.
None
MAINT. AREA:
DLS
START DATE:
20200122
STOP DATE:
N/A
REPAIRED BY:
N/A
MAN HOURS:
N/A
COST:
N/A
N/A MSI DLSr 051
Unclassified Page 31 of 42
200240101 CARRY OVER:
No output reported from DLSr at RWER
No pulses present, oscillator will not calibrate, no output.
RMA requested from
MSI.
None
MAINT. AREA:
DLS
START DATE:
20200124
STOP DATE:
N/A
REPAIRED BY:
N/A
MAN HOURS:
N/A
COST:
N/A
N/A MSI DLSr 030
201150001 CARRY OVER:
TriCaster will not boot.
Awaiting RMA from
NewTek.
No mission impact noted.
MAINT. AREA:
VIDEO
START DATE:
20200424
STOP DATE:
N/A
REPAIRED BY:
N/A
MAN HOURS:
N/A
COST:
N/A
Unclassified Page 32 of 42
201190001 CARRY OVER:
1801 Building UPS has
Temperature alarm and cycles on and off.
Awaiting for GE tech rep to arrive for system troubleshooting.
No mission impact noted.
MAINT. AREA:
1801 UPS
START DATE:
20200428
STOP DATE:
N/A
REPAIRED BY:
N/A
MAN HOURS:
N/A
COST:
N/A
201250001 1801 VHF has intermittent garbled transmit audio.
Removed and replaced
URC-200 radio with parts on hand.
Operational checks good.
No mission impact noted.
MAINT. AREA:
COMM
START DATE:
20200504
STOP DATE:
20200504
REPAIRED BY:
J.TINSLEY
MAN HOURS:
0.5
COST:
N/A
0.5 N/A N/A N/A
Unclassified Page 33 of 42 Distribution: A
RIS NUMBER: DISCREPANCY: ACTION TAKEN: MISSION IMPACT:
201250002 APTM data inoperative at the aircraft. Requires an operations check prior to mission.
Operational checks good. No mission impact noted.
MAINT. AREA:
APTM
START DATE:
20200504
STOP DATE:
20200509
REPAIRED BY:
J.TINSLEY
MAN HOURS:
0.5
COST:
N/A
121.0 N/A N/A N/A
201270001 SUBE AND SUBW
DLSr’s are inoperative.
SUBE required a power cycle. SUBW had antenna cable removed for building maintenance.
Operational checks good.
No mission impact noted.
MAINT. AREA:
DLS
START DATE:
20200506
STOP DATE:
20200506
REPAIRED BY:
J.TINSLEY
MAN HOURS:
1.0
COST:
N/A
1.0 N/A N/A N/A
Unclassified Page 34 of 42
201310001 AATTCS Console 8 requires conversion to old system for mission support.
Conversion complied with.
Operational checks good.
No mission impact noted.
MAINT. AREA:
AATTCS
START DATE:
20200511
STOP DATE:
20200512
REPAIRED BY:
D.CONTRERAS
MAN HOURS:
1.0
COST:
N/A
15.5 N/A N/A N/A
201330001 Copper cable bundle 04-
03 cut by lightning arrestor contractor during
B1801 install.
N/A. Opened for documentation only.
No mission impact noted.
MAINT. AREA:
COMM
START DATE:
20200512
STOP DATE:
20200512
REPAIRED BY:
N/A
MAN HOURS:
N/A
COST:
N/A
Unclassified Page 35 of 42 Distribution: A
RIS NUMBER: DISCREPANCY: ACTION TAKEN: MISSION IMPACT:
201330002 Camera control was lost on both cameras at
Subscale launch pad.
Removed and replaced
Pelco Fiber transmitter with parts on hand.
Operational checks good.
No mission impact noted.
MAINT. AREA:
VIDEO
START DATE:
20200512
STOP DATE:
20200514
REPAIRED BY:
D.CONTRERAS
MAN HOURS:
3.5
COST:
N/A
52.0 N/A N/A N/A
201350001 Comm Room 81st
Workstation EI has sidetone present when there should not be.
Removed and replaced EI with parts on hand.
Operational checks good.
No mission impact noted.
MAINT. AREA:
COMM
START DATE:
20200514
STOP DATE:
20200514
REPAIRED BY:
B.WIEBKE
MAN HOURS:
1.0
COST:
N/A
1.5 N/A N/A N/A
Unclassified Page 36 of 42
201350002 SUBW Camera has a broken pan gear.
Removed camera to repair gear.
Reinstalled camera.
Operational checks good.
No mission impact noted.
MAINT. AREA:
VIDEO
START DATE:
20200514
STOP DATE:
20200521
REPAIRED BY:
D.CON/B.WIE
MAN HOURS:
6.0
COST:
N/A
170.0 N/A N/A N/A
201360001 Open:
ACDS Missile Left has fault in Exciter or HPA.
Removed HPA and sent in for repair.
No mission impact noted.
MAINT. AREA:
COMM
START DATE:
20200515
STOP DATE:
N/A
REPAIRED BY:
N/A
MAN HOURS:
N/A
COST:
N/A
Unclassified Page 37 of 42 Distribution: A
RIS NUMBER: DISCREPANCY: ACTION TAKEN: MISSION IMPACT:
201360002 AATTCS switch #2 failed.
Removed switch from
Newtek system and installed as AATTCS switch #2.
Operational checks good.
No mission impact noted.
MAINT. AREA:
AATTCS
START DATE:
20200515
STOP DATE:
20200515
REPAIRED BY:
K.GIAWASHI
MAN HOURS:
1.0
COST:
N/A
1.0 N/A N/A N/A
201360003 No video at full-scale maintenance control.
Found degraded fiber path.
Rerouted video.
Operational checks good.
No mission impact noted.
MAINT. AREA:
VIDEO
START DATE:
20200515
STOP DATE:
20200515
REPAIRED BY:
D.CONTRERAS
MAN HOURS:
3.0
COST:
N/A
8.0 N/A N/A N/A
Unclassified Page 38 of 42
201360004 During CDT checks on
AATTCS console 8, the touchscreen was unresponsive.
Removed and replaced touchscreen with parts on hand.
Operational checks good.
No mission impact noted.
MAINT. AREA:
AATTCS
START DATE:
20200515
STOP DATE:
20200515
REPAIRED BY:
J.TIN/D.CON
MAN HOURS:
2.0
COST:
N/A
1.0 ELO ET1900L C09L030259
201470001 B9310 APC UPS fails intermittently.
Removed and replaced
UPS battery.
Operational checks good.
No mission impact noted.
MAINT. AREA:
COMM
START DATE:
20200526
STOP DATE:
20200526
REPAIRED BY:
B.WIE/K.GIA
MAN HOURS:
4.0
COST:
N/A
2.0 APC 2200 BATTERY 7A2009L59436
Unclassified Page 39 of 42
TAB 8 – FACILITIES OPEN WORK REQUESTS
TOP FIVE WORK REQUESTS
TOP 5
JOB NO.
BLDG WORK DESCRIPTION STATUS DATE
SUBMITTED
38912
1801 Repair raised floor in room 114. Note:
Submitted by the 81st Range Control Squadron.
CES/CEO
REVIEW
25 Jan 18
39890 239 Repair 239 above-ground storage tank CES/CENPD
REVIEW
13 Nov 19
8513 LP Gate Repair CES
REVIEW
31 Jul 19
38125
45 Pave access road/checkpoint. CES/CENPD
REVIEW
1 Apr 15
59188
Extend existing permanent static ground system inside buildings.
CES/CENM
7 Aug 13
Full Scale Facilities – Building Manager – S. Davis
JOB NO. BLDG WORK DESCRIPTION STATUS DATE SUBMITTED
38125 45 Pave access road/checkpoint.
CES/CENPD
REVIEW
1-Apr-15
59222 45 Roadway Improvement
CES/CENP
REVIEW
21-Nov-13
E2953 9310
Plumb emergency eyewash drain to the building exterior. Install shower pans under emergency showers in Bays 1 and 3 and plumb to drain outside.
CES/FM
PLUMBER
AWT
SCHEDULE
11-Aug-17
38672 9310 Install 26 electrical outlets.
CES/CENP
REVIEW
24-Jan-17
G-0425 9310 Install ice maker
CES/CENPD
IN WORK
26-Jul-19
Unclassified Page 40 of 42 Distribution: A
Range Instrumentation Systems Facilities – Building Manager - R. Williams
JOB NO. BLDG WORK DESCRIPTION STATUS DATE
SUBMITTED
38912 1801 Repair raised floor in room 114. Note:
Submitted by the 81st Range Control Squadron.
CES/CEO
REVIEW
25 Jan 2018
39126 9401 Paint facility. Paint samples collected by CE for Lead
Based Paint testing.
CES/ALOP
SUBMITTED
16 Aug 2018
39211 9350 Replace galvanized communication tower due to
Hurricane Michael damage
CES/ALOP
SUBMITTED
13 Dec 2018
39210 9349 Replace galvanized communication tower due to
Hurricane Michael damage
CES/ALOP
SUNMITTED
13 Dec 2018
39209 1810 Replace galvanized communication tower due to
Hurricane Michael damage
CES/ALOP
SUBMITTED
13 Dec 2018
39285 9352 Tower Alignment-Tensioning and LPS repair CES/ALOP
SUBMITTED
10 Jan 2019
39297 9317 R&R 20’ Tower Ladder. Reinstall LPS
(Ladder Portion Complete)
CES/ALOP
SUBMITTED
(In Progress)
10 Jan 2019
39389 9401 R&R Perimeter Security Fence CES/ALOP
SUBMITTED
31 Jan 2019
39431 9901 Comprehensive tower inspection
(St. George Island)
CES/ALOP
SUBMITTED
13 Feb 2019
G4809 9404 Tower Clearance Light Inoperative CLOSED 27 Mar 2020
G5222 9401 Emergency Light Inop CES/ALOP
SUBMITTED
12 May 2020
Unclassified Page 41 of 42 Distribution: A
Sub Scale Launch Pad – Building Manager - B. Prince
JOB
NO.
BLDG WORK DESCRIPTION STATUS DATE
SUBMITTED
34672 8500 Area Paint buildings and floors. CES/CEPD
REVIEW
24 Jan 06
37441 8519 Install pavement southwest of building.
Project No. XLWU142051D
CES/CENPD
CONTRACT
15 Jun 12
59188 8519
Extend existing permanent static ground system inside buildings.
CES/CENM
REVIEW
7 Aug 13
C7092 8519 Install emergency eyewash/shower stations in the north and south bays.
CES/PLUMER
IN PROGRESS
24 Nov 15
F2434 8525
Rail #4
Repair rail #4 hoist electrical power conduit. CES/ALOP
SUBMITTED
30 Aug 18
8513 LP Gate Repair CES/CEPD
Review
30 Jul 19
G0555 8519 Overhead Light fixture repair CES
Submitted
30 Jul 19
Sub Scale Maintenance Facilities – Building Manager - D. Jacobs
JOB NO. BLDG WORK DESCRIPTION STATUS DATE
SUBMITTED
39890 239 Repair 239 above ground storage tank CES/CENPD
13 Nov 19
TAB 9 – CONTRACTOR PROGRAM MANAGEMENT CONCERNS
The lack of aircraft deliveries from Boeing is impacting our overall aircraft fleet numbers as well as our ability to manage aircraft hours. Once Boeing has worked through production issues, we expect the number of aircraft deliveries will increase past the 2 deliveries/month as called out in the PWS.
This will impact PAE’s ability to meet Safe Flight time requirements and create a backlog of aircraft awaiting Safe Flights.
Unclassified Page 42 of 42 Distribution: A
All the cleanup of failed data documentation and maintenance processes in aircraft generation from
AMARG and/or Boeing continues to fall on PAE for correction prior to SAFE flight.
Failure to receive delivery aircraft is impacting available manned flyers (Tyndall & Holloman).
Correspondingly, NULLO fleet health/quantity is becoming an issue. Expect continued movement of aircraft to and from Holloman and early De-Man of flyers to keep Tyndall’s NULLO fleet minimally populated.
Severe damage to most of our facilities is causing many workarounds and much turmoil. PAE is managing the situation the best we can. Construction of temporary facilities is almost complete and for the most part the facilities are adequate with a few workarounds.
A major concern is safely moving into temporary facilities while still complying with all AF regulations governing the safe handling and storage of explosive items. Also, we are being told all 5 of the temporary facilities (chute shop & SSAT Mx tents) will have to move. There is a major concern of meeting mission support while moving all 5 tents.