Attachment 3 AF Form 66 - Repair HVAC H7 H9 B32 and B127.xls.pdf

Air Force Form PDF 97 KB Posted

Attached to
Repair HVAC H7, H9, B32 B127 _Project: VGLZ212011_Selfridge ANGB
Solicitation number
W50S85-21-B-0004
Issued by

About this file

This document contains a submittal schedule and material submittal requirements for a federal contract to repair HVAC systems at Selfridge Air National Guard Base. The contract is for $250,000 to $500,000 between the Department of the Army Michigan Army National Guard and small businesses. Offerors must have an approved business plan on file with the Detroit, MI District and the NAICS code is 238220. The period of performance is 365 calendar days. The submittal schedule requires the contractor to provide various documents and plans within specified timeframes after notice to proceed, including shop drawings, warranties, testing and balancing reports, operation and maintenance manuals, and project closeout documentation. Material submittals are grouped by specification section and type, such as product data, samples, or manufacturer recommendations.

View the file

Other versions and copies of AF Form 66

File Revision Posted Attached to
Attachment 09-AF form 66 03.27.2025.pdf Mar 27, 2025 B611 HVAC Repair
Attachment 2 AF Form 66.pdf Revision not stated REPAIR AC PAVING
AF form 66 Blank.pdf Revision not stated Demo Mini mute sites
AF Form 66-EEPZ260842 Renovate Convert Comm to SAPR B730.xlsx Revision not stated B730 Renovate Convert Comm to SAPR
AF Form 66 B268.xlsx Revision not stated B268 Replace STUS Backup Generator
AF Form 66 B730.xlsx Revision not stated B730 - Renovate RM106 for Emergency Operations Center
AF Form 66.xlsx Revision not stated B836 Replace Electrical in Airfield Lighting Vault
AF Form 66 OSI Flooring.xlsx Revision not stated OSI B926 Flooring
EEPZ254660 Repair Control Tower HVAC B1806 - AF Form 66.xlsx Revision not stated B1806 Repair Control Tower HVAC
AF Form 66 Template.xlsx Revision not stated Replace AAS BAK-15 Controls, B2001, B2003
AF Form 66 EEPZ216808 Replace Security Forces Elevator B926.xlsx Revision not stated B926 Replace Security Forces Elevator
WT 17518487 AF Form 66.xlsx Revision not stated Repair Structural Fire Trainer B17903, 17904
AF Form 66.xlsx Revision not stated RENOVATE/CONVERT 50th 49th SQ OPS, B230
AF Form 66.xlsx Revision not stated T-6 Flightline Shacks
AF Form 66 Template.xlsx Revision not stated Replace Fire Alarms, Multi Facility
EEPZ248229 -- AF Form 66.xlsx Revision not stated Repair Kiddie Pool
Atch 2 AF Form 66.pdf Revision not stated Removal of Underground Storage Tank at Launch Facility E-10 (Laramie County, WY)
Attachment 4 - AF Form 66 Submittal Register.pdf Revision not stated Bldg 65 - Renovation of Telephone Office Area, FE Warren AFB, WY AMENDMENT 03
Attachment 7 - AF Form 66.xlsx Revision not stated Replace Chapel Windows B912
04 - AF form 66.xlsx Revision not stated New Poinsett Tower Installation
Show all 20

Who attaches AF Form 66

State Files
Iowa 1
Massachusetts 1

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT NO.

VGLZ 212011

APPROVED DISAPPROVED

1 Submittal Schedule - AF Form 66 10

2 Transfer and Acceptance of DOD Real Property - DD Form 1354 60

3 Contractor Hazardous Material Identification - SANGB Form 23 10

4 Solid Waste Recycling and Disposal Reporting Form 72 60

5 Affirmative Procurement Reporting Form 60

6 DD Form 1354 60

7 Construction Schedule AF 3064 submittals 10

8 Construction Photos 45

9 Safety Documentation as stated 10

10 Schedule of Test and Inspections 21

11 Permits, Licenses and Certificates 10

12 Quality Control Plan 10

13 Warranties 10

14 Starting System -Testing, Adjusting & Balancing Reports 60

15 O & M Data 15

Project Record Documents Close out Documantation 60

17 Instructional Training Program as applicable 60

Product Data

Common Motor Requirements for HVAC Equipment Product Data 15

18 Sleeves and Sleeve Seal for HVAC Piping 19 Product Data for General Duty Valves 15 20 Escutcheons for HVAC Piping 21 Product Data as req'd 22 Meters and Gages for HVAC Piping

Product Data for Meters and Gages as req'd

Spec Section

C

ER

TI

FI

C

AT

IO

N

O F

C O

M

PL

IA

N

C E

AN

D

C

LO

SE

O

U T

SOLICITATION/CONTRACT NO.PROJECT TITLE

Repair HVAC H7, H9, B32 and B127

SCHEDULE OF MATERIAL SUBMITTALS

(AF Form 66 Modified)

NO. OF COPIES REQUIRED

TO BE COMPLETED BY PROJECT ENGINEER

O

PE

R

AT

IN

G

IN

ST

R U

C

TI

O N

S

C

AT

AL

O

G D

AT

A

LI

N

E N

U M

BE

R

M

AN

U

FA

C

TU

R

ER

'S W

AR

R

AN

TY

O

TH

ER

M

AT

ER

IA

L o r

D

AT

A

SH

O

P D

R

AW

IN

G

S

SA

M

PL

ES

C O

LO

R

S

EL

EC

TI

O N

M

AN

U

FA

C

TU

R

ER

'S

R

EC

O M

M

EN

D

AT

IO

N

S

REMARKSFINAL

APPROVAL

CONTRACTOR

RESUBMITTAL

RETURN

SUSPENSION

DATE

ITEM OR DESCRIPTION OF ITEM,

CONTRACT REFERENCE, TYPE OF

SUBMITTAL

FOLLOW-UP

SUBMITTAL

REQUIRED

BY XX DAYS

AFTER

NTP

DATE

RECEIVED

IN

CONTRACTING

DATE

TO

CIVIL

ENGINEERING

DATE CONTRACTOR NOTIFIED

APPROVED DISAPPROVED

Spec Section

C

ER

TI

FI

C

AT

IO

N

O F

C O

M

PL

IA

N

C E

AN

D

C

LO

SE

O

U T

SOLICITATION/CONTRACT NO.PROJECT TITLE

Repair HVAC H7, H9, B32 and B127

SCHEDULE OF MATERIAL SUBMITTALS

(AF Form 66 Modified)

NO. OF COPIES REQUIRED

TO BE COMPLETED BY PROJECT ENGINEER

O

PE

R

AT

IN

G

IN

ST

R U

C

TI

O N

S

C

AT

AL

O

G D

AT

A

LI

N

E N

U M

BE

R

M

AN

U

FA

C

TU

R

ER

'S W

AR

R

AN

TY

O

TH

ER

M

AT

ER

IA

L o r

D

AT

A

SH

O

P D

R

AW

IN

G

S

SA

M

PL

ES

C O

LO

R

S

EL

EC

TI

O N

M

AN

U

FA

C

TU

R

O M

M

EN

D

AT

IO

N

S

REMARKSFINAL

APPROVAL

CONTRACTOR

RESUBMITTAL

RETURN

SUSPENSION

DATE

ITEM OR DESCRIPTION OF ITEM,

CONTRACT REFERENCE, TYPE OF

SUBMITTAL

FOLLOW-UP

SUBMITTAL

REQUIRED

BY XX DAYS

AFTER

NTP

DATE

RECEIVED

IN

CONTRACTING

DATE

TO

CIVIL

ENGINEERING

DATE CONTRACTOR NOTIFIED

Shop Drawing as req'd O & M Data as req'd Warranty as req'd

23 General-Duty Valves for HVAC Piping as req'd Product Data for General Duty Valves as req'd

Hangers & Supports for HVAC Piping & Equipment Product Data as req'd Shop Drawing as req'd O & M Data as req'd Warranty as req'd

Identifcation for HVAC Piping and Equipment Product Data as req'd Sample for ID as req'd Equipment Label Schedule / Scheme as req'd Valve Schedule as req'd

26 Testing, Adjusting, & Balancing for HVAC Qualification Data Contract Document Examination Report 60 Certified TAB Reports 60

27 HVAC Piping Insulation

Product Data on Insulation as req'd Samples of Insulation as req'd

28 Instrumentation & Control for HVAC Product Data on DDC System & Controls 15 Shop Drawing 15 Data Comm. Protocol Certificates 15

29 Control Valves Product Data 15 Shop Drawing 15 O & M Data 15 Warranty 15

30 Control Dampers Product Data as req'd Shop Drawing as req'd O & M Data as req'd Warranty as req'd

31 Sequence of Operation for HVAC DDC Control Sequences 15

33 Hydronic Piping Product Data on the following Material: 15 Air Control Devices 15

APPROVED DISAPPROVED

Spec Section

C

ER

TI

FI

C

AT

IO

N

O F

C O

M

PL

IA

N

C E

AN

D

C

LO

SE

O

U T

SOLICITATION/CONTRACT NO.PROJECT TITLE

Repair HVAC H7, H9, B32 and B127

SCHEDULE OF MATERIAL SUBMITTALS

(AF Form 66 Modified)

NO. OF COPIES REQUIRED

TO BE COMPLETED BY PROJECT ENGINEER

O

PE

R

AT

IN

G

IN

ST

R U

C

TI

O N

S

C

AT

AL

O

G D

AT

A

LI

N

E N

U M

BE

R

M

AN

U

FA

C

TU

R

ER

'S W

AR

R

AN

TY

O

TH

ER

M

AT

ER

IA

L o r

D

AT

A

SH

O

P D

R

AW

IN

G

S

SA

M

PL

ES

C O

LO

R

S

EL

EC

TI

O N

M

AN

U

FA

C

TU

R

O M

M

EN

D

AT

IO

N

S

REMARKSFINAL

APPROVAL

CONTRACTOR

RESUBMITTAL

RETURN

SUSPENSION

DATE

ITEM OR DESCRIPTION OF ITEM,

CONTRACT REFERENCE, TYPE OF

SUBMITTAL

FOLLOW-UP

SUBMITTAL

REQUIRED

BY XX DAYS

AFTER

NTP

DATE

RECEIVED

IN

CONTRACTING

DATE

TO

CIVIL

ENGINEERING

DATE CONTRACTOR NOTIFIED

Hydronic Specialties 15 O & M Data 15

34 Hydronic Piping Specialities Product Data 15 Shop Drawing 15 Warranty 15 O & M Data 15

35 Hydronic Pumps Product Data 15 Shop Drawing 15 Warranty 15 O & M Data 15

Water Treatment for Closed-Loop Hydronic Systems Product Data 15 Shop Drawing 15 Warranty 15 O & M Data 15

37 Condensing Boilers Product Data 15 Shop Drawings 15 exhaust piping Concentric walll side Warranty 15 O & M Data 15

Low-Voltage Electrical Power Conductors & Cables Product Data for Each Type of Cable as req'd

Grounding & Bonding for Electrical Systems O & M Data as req'd

40 Raceway & Boxes for Electrical Systems Product Data on the following Material: as req'd Metal Conduit & Tubing as req'd Metal Wireways as req'd Surface Raceways as req'd Boxes, Enclosures, Cabinets as req'd

41 Panelboards Product Data as req'd Shop Drawings as req'd O & M Data as req'd Warranty as req'd

42 Enclosed Switches Product Data as req'd Shop Drawings as req'd

APPROVED DISAPPROVED

Spec Section

C

ER

TI

FI

C

AT

IO

N

O F

C O

M

PL

IA

N

C E

AN

D

C

LO

SE

O

U T

SOLICITATION/CONTRACT NO.PROJECT TITLE

Repair HVAC H7, H9, B32 and B127

SCHEDULE OF MATERIAL SUBMITTALS

(AF Form 66 Modified)

NO. OF COPIES REQUIRED

TO BE COMPLETED BY PROJECT ENGINEER

O

PE

R

AT

IN

G

IN

ST

R U

C

TI

O N

S

C

AT

AL

O

G D

AT

A

LI

N

E N

U M

BE

R

M

AN

U

FA

C

TU

R

ER

'S W

AR

R

AN

TY

O

TH

ER

M

AT

ER

IA

L o r

D

AT

A

SH

O

P D

R

AW

IN

G

S

SA

M

PL

ES

C O

LO

R

S

EL

EC

TI

O N

M

AN

U

FA

C

TU

R

O M

M

EN

D

AT

IO

N

S

REMARKSFINAL

APPROVAL

CONTRACTOR

RESUBMITTAL

RETURN

SUSPENSION

DATE

ITEM OR DESCRIPTION OF ITEM,

CONTRACT REFERENCE, TYPE OF

SUBMITTAL

FOLLOW-UP

SUBMITTAL

REQUIRED

BY XX DAYS

AFTER

NTP

DATE

RECEIVED

IN

CONTRACTING

DATE

TO

CIVIL

ENGINEERING

DATE CONTRACTOR NOTIFIED

O & M Data as req'd 43 Enclosed Controllers

Product Data as req'd Shop Drawings as req'd O & M Data as req'd

44 Roof Patching Product Data as req'd Shop Drawings as req'd O & M Data as req'd

File details come from the government source that posted it. Updated .