Attachment 22 - Seed Project AF Form 66.pdf

Air Force Form PDF 93 KB Posted

Attached to
Hazardous Materials Abatement Contract - IDIQ
Solicitation number
FA500023B0003
Issued by

About this file

This document is the AF Form 66, which is a Schedule of Material Submittals for a federal contract opportunity to repair a hazardous materials survey facility. The contract opportunity is related to Solicitation Number FA500023B0003 for a Hazardous Materials Abatement Contract - IDIQ with a broad range of work to prepare remediation plans and abatement strategies.

The AF Form 66 lists various submittals required from the contractor, including the construction schedule, QA/QC plan, safety plan, hazardous materials disposal reports, and other documentation. The required submission dates and approvals are tracked. The seed project for this IDIQ contract is valued between $25,000 and $100,000. This requirement is a 100% small business set-aside.

View the file

Other versions and copies of AF Form 66

File Revision Posted Attached to
Attachment 2 AF Form 66.pdf Revision not stated REPAIR AC PAVING
AF form 66 Blank.pdf Revision not stated Demo Mini mute sites
Attach 9_AF Form 66 Submittal Register.pdf Revision not stated PKAA Dorm Water Damage Repair (Construction)
AF Form 66-EEPZ260842 Renovate Convert Comm to SAPR B730.xlsx Revision not stated B730 Renovate Convert Comm to SAPR
AF Form 66_EEPZ254664-B972 UOQ.xlsx Revision not stated B972 Renovate UOQ Community Commons
AF Form 66 B268.xlsx Revision not stated B268 Replace STUS Backup Generator
AF Form 66 B730.xlsx Revision not stated B730 - Renovate RM106 for Emergency Operations Center
AF Form 66.xlsx Revision not stated B836 Replace Electrical in Airfield Lighting Vault
AF Form 66 OSI Flooring.xlsx Revision not stated OSI B926 Flooring
EEPZ254660 Repair Control Tower HVAC B1806 - AF Form 66.xlsx Revision not stated B1806 Repair Control Tower HVAC
AF Form 66 Template.xlsx Revision not stated Replace AAS BAK-15 Controls, B2001, B2003
AF Form 66 EEPZ216808 Replace Security Forces Elevator B926.xlsx Revision not stated B926 Replace Security Forces Elevator
WT 17518487 AF Form 66.xlsx Revision not stated Repair Structural Fire Trainer B17903, 17904
AF Form 66.xlsx Revision not stated RENOVATE/CONVERT 50th 49th SQ OPS, B230
AF Form 66.xlsx Revision not stated T-6 Flightline Shacks
AF Form 66 Template.xlsx Revision not stated Replace Fire Alarms, Multi Facility
EEPZ248229 -- AF Form 66.xlsx Revision not stated Repair Kiddie Pool
Atch 2 AF Form 66.pdf Revision not stated Removal of Underground Storage Tank at Launch Facility E-10 (Laramie County, WY)
Attachment 4 - AF Form 66 Submittal Register.pdf Revision not stated Bldg 65 - Renovation of Telephone Office Area, FE Warren AFB, WY AMENDMENT 03
Attachment 7 - AF Form 66.xlsx Revision not stated Replace Chapel Windows B912
Show all 20

Who attaches AF Form 66

State Files
Iowa 1
Massachusetts 1

Other files

File Type Posted
Abstract.pdf PDF
Solicitation Amendment FA500024B00030002.pdf PDF
Solicitation Amendment FA500024B00030001 SF 30.pdf PDF
Attachment 25 - Questions and Answers.pdf PDF
Attachment 7_Dig Permit Custom Map Richardson.pdf PDF
Attachment 17_Wage Determination_AK20240001 02_23_2024.pdf PDF
Attachment 12_Environmental Precon Checklist_Updated Sep 19.pdf PDF
Attachment 21 - Seed Project Price Schedule.pdf PDF
Attachment 18_Service Contract Act_Dec25_2023-Revision 19.pdf PDF
Attachment 1_HMAC _Dated 12 Dec 2023 SOW.pdf PDF
Attachment 6_Dig Permit Custom Map Elmendorf.pdf PDF
Attachment 9_JBER IFS Vol 1 Elmendorf_31 January 2019.pdf PDF
Attachment 20 - Seed Project As-builts.pdf PDF
Attachment 3_AF IMT 3064_2003091_VI_Progress Schedule.pdf PDF
Attachment 16_JBER Integrated Hazardous Material Plan 25 Oct 2020.pdf PDF
Attachment 8_Dig Permit Fillable Template_ 673ABW Form 3_20200423_Prescribed by 673ABWI32_1007.pdf PDF
Attachment 2_AF IMT 3000_2003091_VI_ Submittal.pdf PDF
Attachment 14_JBER Hazardous Waste Management Plan - 2024.pdf PDF
Attachment 10_JBER IFS Vol 2 Richardson_14 February 2019.pdf PDF
Attachment 24 - FOPR Seed Project FXSB 24-1008.pdf PDF
Solicitation - FA500024B0003.pdf PDF
Attachment 5_Contractors Fire Safety Guide_Rev 14_14 September 2017.pdf PDF
Attachment 13_JBER 1500_1600 Environmental Protection and Solid Waste Management Specs 26 Jul 23.pdf PDF
Attachment 4_AF IMT 3065_199600401_VI_Progress Report.pdf PDF
Attachment 11_JBER CAD GIS Record Drawing As- Built Standard_Dec 2019.pdf PDF
Attachment 15_JBER Telecom Criteria Requirements_ February 11 2021.pdf PDF
Attachment 23 - Seed Project Location map.pdf PDF
Attachment 19 - Seed Project SOW.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LI

N

E N

U M

B ER Note: Government will retain all submittals. Provide an electronic copy for each submittal.

C

ER

TI

F.

O F

C O

M

PL

IA

N

C E

SH

O

P D

R

AW

IN

G

S

C O

LO

R

S

EL

EC

TI

O N

M

AN

U

FA

TU

R

U R

'S R

EC

O

M M

EN

D

AT

IO

N

C

AT

AL

O

G D

AT

A

O &M

R

EC

O M

M

EN

D

AT

IO

N

S

C

AL

C U

LA

TI

O N

S

W

AR

R

AN

TY

D R

AW

IN

G S

R

EP

O R

T

TE

ST

R

ES

U

LT

S

R

EQ

U

IR

ED

S

U

BM

IS

SI

O N

D

AT

E

D

AT

E

TO

C O

N

TR

AC

TI

N G

D

AT

E

TO

C

IV

IL

E

N G

IN

EE

R

IN

G

R

ET

U R

N S

U

SP

EN

SE

D

AT

E

SU

BM

IT

TA

L N

U M

BE

R

S

AP

PR

O

VE

D

D

IS

AP

PR

O

VE

D

C O

N

TR

AC

TO

R S

U

BM

IT

TA

L

FI

N

AL

A

PP

R

O

VA

L

GENERAL

1 Project Specific Form 66 X NTP + 10

2 Construction Schedule (AF IMT 3064) X NTP + 10

3 Project Specific Specifications X NTP + 10

4 Contractor's QA/QC Plan X NTP + 14

5 Contractor's Environment Plan X NTP + 14

6 Contractor's Safety Plan X NTP + 14

7 Contractor's Health Plan X NTP + 14

8 Written Hazard Communication Program X NTP + 14

9 HazMat Disposal Reports per Environmental Protection Specifications on JBER X NTP + 14

Submit all notifications to the Alaska Occupational Safety and Health (AKOSH) and EPA Region 10 that are mandatory before starting any asbestos work.

before start work

11 Asbestos abatement plan X NTP + 14

SCHEDULE OF MATERIAL SUBMITTALS

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACT ADMINISTRATOR

PROJECT NUMBER PROJECT NAME SOLICITATION /CONTRACT NUMBER

FXSB 24-1008 Repair Hazmat survey B31550

AF FORM 66

E N

U M

B ER Note: Government will retain all submittals. Provide an electronic copy for each submittal.

C

ER

TI

F.

O F

C O

M

PL

IA

N

C E

SH

O

P D

R

AW

IN

G

S

C O

LO

R

S

EL

EC

TI

O N

M

AN

U

FA

TU

R

U R

'S R

EC

O

M M

EN

D

AT

IO

N

C

AT

AL

O

G D

AT

A

O &M

R

EC

O M

M

EN

D

AT

IO

N

S

C

AL

C U

LA

TI

O N

S

W

AR

R

AN

TY

D R

AW

IN

G S

R

EP

O R

T

TE

ST

R

ES

U

LT

S

R

EQ

U

IR

ED

S

U

BM

IS

SI

O N

D

AT

E

D

AT

E

TO

C O

N

TR

AC

TI

N G

D

AT

E

TO

C

IV

IL

E

N G

IN

EE

R

IN

G

R

ET

U R

N S

U

SP

EN

SE

D

AT

E

SU

BM

IT

TA

L N

U M

BE

R

S

AP

PR

O

VE

D

D

IS

AP

PR

O

VE

D

C O

N

TR

AC

TO

R S

U

BM

IT

TA

L

FI

N

AL

A

PP

R

O

VA

L

SCHEDULE OF MATERIAL SUBMITTALS

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACT ADMINISTRATOR

PROJECT NUMBER PROJECT NAME SOLICITATION /CONTRACT NUMBER

FXSB 24-1008 Repair Hazmat survey B31550

12 Medical Certification X NTP + 14

13 Landfill Approval X NTP + 14

14 Hazardous material Sampling and analysis plan and schedule. X NTP + 14

15 Hazard Material List with Safety Data Sheets (SDSs) X

14 days Prior to bringing any materials on base.

16 Accumulation point daily and weekly inspection summary sheets X

Once per week after issue of Starting Work on Order

17 Name, phone number and experience resume of the Emergency Coordinator X

Once per week after issue of Starting Work on Order

18 Record of Training for Contractor Employees X NTP + 14

19 Testing Laboratory X NTP + 21

20 Daily Reports X

24 hrs after issue of

Starting Work on Order

21 Copy of all Signed Landfill Disposal Records X 7 days Prior to final inspection

E N

U M

B ER Note: Government will retain all submittals. Provide an electronic copy for each submittal.

C

ER

TI

F.

O F

C O

M

PL

IA

N

C E

SH

O

P D

R

AW

IN

G

S

C O

LO

R

S

EL

EC

TI

O N

M

AN

U

FA

TU

R

U R

'S R

EC

O

M M

EN

D

AT

IO

N

C

AT

AL

O

G D

AT

A

O &M

R

EC

O M

M

EN

D

AT

IO

N

S

C

AL

C U

LA

TI

O N

S

W

AR

R

AN

TY

D R

AW

IN

G S

R

EP

O R

T

TE

ST

R

ES

U

LT

S

R

EQ

U

IR

ED

S

U

BM

IS

SI

O N

D

AT

E

D

AT

E

TO

C O

N

TR

AC

TI

N G

D

AT

E

TO

C

IV

IL

E

N G

IN

EE

R

IN

G

R

ET

U R

N S

U

SP

EN

SE

D

AT

E

SU

BM

IT

TA

L N

U M

BE

R

S

AP

PR

O

VE

D

D

IS

AP

PR

O

VE

D

C O

N

TR

AC

TO

R S

U

BM

IT

TA

L

FI

N

AL

A

PP

R

O

VA

L

SCHEDULE OF MATERIAL SUBMITTALS

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACT ADMINISTRATOR

PROJECT NUMBER PROJECT NAME SOLICITATION /CONTRACT NUMBER

FXSB 24-1008 Repair Hazmat survey B31550

22 Final Hazmat Survey Report 7 days Prior to final inspection

23 Final Remediation/ Abatement plan 7 days Prior to final inspection

AF_66

File details come from the government source that posted it. Updated .