Attachment 2. AF Form 66.xlsx

Air Force Form XLSX spreadsheet 16 KB Posted

Attached to
P400 - Demolition of four buildings at Fort Richardson, JBER, AK.
Solicitation number
FA500023Q0035
Issued by

About this file

This document contains a schedule of material submittals for a demolition project at Joint Base Elmendorf-Richardson in Alaska. The Air Force is soliciting offers from economically-disadvantaged woman-owned small businesses to demolish four unaccompanied housing units under solicitation number FA500023Q0035. The schedule outlines 22 required submittals and their due dates related to hazardous materials handling, quality control, environmental protection, and utility isolation plans. Key submittals include a hazardous material approval and usage report, safety data sheets, a waste management plan if lead or asbestos are present, and documentation of training for contractor employees. Offerors should refer to the solicitation for additional requirements and details such as a tentative site visit scheduled for June 1st.

View the file

Other versions and copies of AF Form 66

File Revision Posted Attached to
Attachment 2 AF Form 66.pdf Revision not stated REPAIR AC PAVING
AF form 66 Blank.pdf Revision not stated Demo Mini mute sites
Attach 9_AF Form 66 Submittal Register.pdf Revision not stated PKAA Dorm Water Damage Repair (Construction)
AF Form 66-EEPZ260842 Renovate Convert Comm to SAPR B730.xlsx Revision not stated B730 Renovate Convert Comm to SAPR
AF Form 66_EEPZ254664-B972 UOQ.xlsx Revision not stated B972 Renovate UOQ Community Commons
AF Form 66 B268.xlsx Revision not stated B268 Replace STUS Backup Generator
AF Form 66 B730.xlsx Revision not stated B730 - Renovate RM106 for Emergency Operations Center
AF Form 66.xlsx Revision not stated B836 Replace Electrical in Airfield Lighting Vault
AF Form 66 OSI Flooring.xlsx Revision not stated OSI B926 Flooring
EEPZ254660 Repair Control Tower HVAC B1806 - AF Form 66.xlsx Revision not stated B1806 Repair Control Tower HVAC
AF Form 66 Template.xlsx Revision not stated Replace AAS BAK-15 Controls, B2001, B2003
AF Form 66 EEPZ216808 Replace Security Forces Elevator B926.xlsx Revision not stated B926 Replace Security Forces Elevator
WT 17518487 AF Form 66.xlsx Revision not stated Repair Structural Fire Trainer B17903, 17904
AF Form 66.xlsx Revision not stated RENOVATE/CONVERT 50th 49th SQ OPS, B230
AF Form 66.xlsx Revision not stated T-6 Flightline Shacks
AF Form 66 Template.xlsx Revision not stated Replace Fire Alarms, Multi Facility
EEPZ248229 -- AF Form 66.xlsx Revision not stated Repair Kiddie Pool
Atch 2 AF Form 66.pdf Revision not stated Removal of Underground Storage Tank at Launch Facility E-10 (Laramie County, WY)
Attachment 4 - AF Form 66 Submittal Register.pdf Revision not stated Bldg 65 - Renovation of Telephone Office Area, FE Warren AFB, WY AMENDMENT 03
Attachment 7 - AF Form 66.xlsx Revision not stated Replace Chapel Windows B912
Show all 20

Who attaches AF Form 66

State Files
Iowa 1
Massachusetts 1

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AF66- Material Submittals

SCHEDULE OF MATERIAL SUBMITTALSPROJECT NUMBER :PROJECT TITLE:SOLICITATION/CONTRACT NO.:
HJZH 21-1099Demo Unaccompanied Housing (Multi-Fac), Bldg 455, 456, 457, 458
TO BE COMPLETED BY PROJECT ENGINEERTO BE COMPLETED BY CONTRACT ADMINISTRATOR
LINE NUMBERITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTALNO. OF COPIES REQUIREDREQUIRED SUBMISSION DATEDATE RECEIVED IN CONTRACTINGDATE TO CIVIL ENGINEERING/ENVIRONMENTALRETURN SUSPENSE DATESUBMITTAL NUMBERSCONTRACTOR RESUBMITTALFINAL APPROVALREMARKS
CERTIFICATION OF COMPLIANCESHOP DRAWINGSSAMPLESCOLOR SELECTIONMANUFACTURER'S RECOMMENDATIONSMANUFACTURER'S WARRANTYCATALOG DATAOPERATING INSTRUCTIONSSAFETY DATA SHEETSOTHERDATE CONTRACTOR NOTIFIED
APPROVEDDIS- APPROVED
1HAZMAT Approval, General Specs 01500, para. 5.1.3 and 5.1.5.xNLT 10 working days prior to material being brought onto installation
2HAZMAT Usage Report, General Specs 01500, para. 5.1.3 and 5.1.5.xNLT 7 Working Days After Final Acceptance
3Quality Control Planx20 Days Prior to work start
4SWPPPx10 Days Prior to Pre-Construction Conference
5Environmental Protection Planx10 Days prior to work start
6LEAD WASTE MANAGEMENT PLAN (If needed)

*Submittal

1.3.2.2xx30 Days prior to abatement work start
7ASBESTOS ABATEMENT WORK PLAN (If needed)

*Submittal

1.3.2.2x30 Days Prior to work start
8Disposal of Lead Containing Material (If needed)

*REQUIREMENTS

1.3.2.4xx30 Days Prior to work start
9Utilities Work

*REQUIREMENTS

1.4xx30 Days Prior to work start
10Water

*REQUIREMENTS

1.4.1x30 Days Prior to work start
11Electrical

*REQUIREMENTS

1.4.3x30 Days Prior to work start
12Natural Gas

*REQUIREMENTS

1.4.5x30 Days Prior to work start
13Hazardous material Sampling and analysis plan and schedule. (If needed)

*REQUIREMENTS

1.5xx30 Days Prior to work start
14Record of Training for Contractor Employees

*REQUIREMENTS

1.5.2xx30 Days Prior to work start
15Daily Reports

*REQUIREMENTS

1.6.1xDaily upon award of contract
16Safety Data Sheets (SDSs)

*REQUIREMENTS

1.5xx30 Days Prior to work start
17Medical Certification

*Submittal (If needed)

1.5.2x30 Days Prior to work start
18Landfill Approval

*Submittal

1.5.1x30 Days Prior to work start
19Testing Laboratory

*Submittal (If needed)

1.3.2xx30 Days Prior to work start
20Accumulation point daily and weekly inspection summary sheets

*REQUIREMENTS

1.5.1xxDaily and weekly upon work start
21Chain Of Custody Documents On Hazardous Materials. (If Needed)
1.5x30 Days after project completion
22Seeding Submittals. (If needed)
1.3.2.10x30 Days Prior to work start

Solicitation No. Attachment 6

AF FORM 66

(Computer Generated) PAGE &P of &N