AF Form 66 - Repair B 825 Lignting.xls
Air Force Form XLS spreadsheet 47 KB Posted
- Attached to
- Replacement of Light Fixtures for Building 825
- Solicitation number
- W50S85-21-B-0014
About this file
This document contains a submittal schedule and product data requirements for a federal construction contract to replace lighting fixtures in Building 825 at Selfridge Air National Guard Base. The contractor must provide LED lighting fixtures of various types and sizes to directly replace existing fixtures, along with associated electrical work and disposal of old materials. Submittals include fixture product data and shop drawings due 15 to 60 days after notice to proceed, as well as operation and maintenance manuals, warranties, and closeout documentation. The contract is issued through the Department of the Army Michigan Army National Guard as solicitation number W50S85-21-B-0014 to replace lights and retrofit the lighting system at the specified location.
View the file
Other versions and copies of AF Form 66
Show all 20
Who attaches AF Form 66
| State | Files |
|---|---|
| Iowa | 1 |
| Massachusetts | 1 |
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
| SCHEDULE OF MATERIAL SUBMITTALS | |||||||||||||||||
| (AF Form 66 Modified) | PROJECT NO. | PROJECT TITLE | SOLICITATION/CONTRACT NO. | ||||||||||||||
| VGLZ 212018 | Repair Lights B 825 | ||||||||||||||||
| TO BE COMPLETED BY PROJECT ENGINEER | |||||||||||||||||
| NO. OF COPIES REQUIRED | |||||||||||||||||
| LINE NUMBER | Spec Section | ITEM OR DESCRIPTION OF ITEM, CONTRACT REFERENCE, TYPE OF SUBMITTAL | CERTIFICATION OF COMPLIANCE AND CLOSEOUT | SHOP DRAWINGS | SAMPLES | COLOR SELECTION | MANUFACTURER'S RECOMMENDATIONS | MANUFACTURER'S WARRANTY | CATALOG DATA | OTHER MATERIAL or DATA | OPERATING INSTRUCTIONS | SUBMITTAL |
REQUIRED
BY XX DAYS
AFTER
NTP DATE
RECEIVED
IN
CONTRACTING DATE
TO
CIVIL
ENGINEERING RETURN
SUSPENSION
| DATE | FOLLOW-UP | DATE CONTRACTOR NOTIFIED | CONTRACTOR RESUBMITTAL | FINAL | |||||
| APPROVAL | REMARKS | ||||||||
| APPROVED | DISAPPROVED | ||||||||
| 1 | Submittal Schedule - AF Form 66 | 10 | |||||||
| 2 | Transfer and Acceptance of DOD Real Property - DD Form 1354 | 60 | |||||||
| 3 | Contractor Hazardous Material Identification - SANGB Form 23 | 10 | |||||||
| 4 | Solid Waste Recycling and Disposal Reporting Form 72 | 20 | |||||||
| 5 | Affirmative Procurement Reporting Form | 60 | |||||||
| 6 | DD Form 1354 | 60 | |||||||
| 7 | Construction Schedule | ||||||||
| AF 3064 submittals | 10 | ||||||||
| 8 | Construction Photos | 45 | |||||||
| 9 | Safety Documentation as stated | 10 | |||||||
| 10 | Schedule of Test and Inspections | 21 | |||||||
| 11 | Permits, Licenses and Certificates | 10 | |||||||
| 12 | Quality Control Plan | 10 | |||||||
| 13 | Warranties | 10 | |||||||
| 14 | Starting System -Testing, Adjusting & Balancing Reports | 60 | |||||||
| 15 | O & M Data | 15 | |||||||
| 16 | Project Record Documents | ||||||||
| Close out Documantation | 60 | ||||||||
| 17 | Instructional Training Program as applicable | 60 | |||||||
| Product Data | |||||||||
| 18 | Common Requirements for LED lighting replacment Fixtures | ||||||||
| Product Data FIXTURES | 15 | ||||||||
| 18 | O & M Data | ||||||||
| 19 | Product Data for lighting fixtures | 30 | |||||||
| 20 | Product Data | ||||||||
| 21 | Warrranty | 30 | |||||||
| 22 | Hangers & Supports for lighting fixtures | ||||||||
| Product Data | as req'd | ||||||||
| Shop Drawing | as req'd | ||||||||
| O & M Data | as req'd | ||||||||
| Warranty | as req'd | ||||||||
| 38 | Low-Voltage Electrical Power Conductors & Cables | ||||||||
| Product Data for Each Type of Cable | as req'd | ||||||||
| 39 | Grounding & Bonding for Electrical Systems | ||||||||
| O & M Data | as req'd | ||||||||
| 40 | Raceway & Boxes for Electrical Systems | ||||||||
| Product Data on the following Material: | as req'd | ||||||||
| Metal Conduit & Tubing | as req'd | ||||||||
| Metal Wireways | as req'd | ||||||||
| Surface Raceways | as req'd | ||||||||
| Boxes, Enclosures, Cabinets | as req'd | ||||||||
| 41 | Panelboards | ||||||||
| Product Data | as req'd | ||||||||
| Shop Drawings | as req'd | ||||||||
| O & M Data | as req'd | ||||||||
| Warranty | as req'd | ||||||||
| 42 | Enclosed Switches | ||||||||
| Product Data | as req'd | ||||||||
| Shop Drawings | as req'd | ||||||||
| O & M Data | as req'd |