About this file
This is a specifications document for Section 05 31 23 - Steel Roof Decking, part of the Biosolids Project 011139.0465 at Ephrata Borough Authority in Pennsylvania. The specification establishes requirements for steel roof deck installation and accessories, including formed steel cant strips, eave strips, valley strips, and framing for openings up to 12 inches. Approved manufacturers include Cordeck, Roof Deck, Inc., and Vulcraft. The steel roof deck shall be fabricated from ASTM A653 Grade 50 Structural Quality sheet steel with G90 galvanized coating, with a minimum metal thickness of 20 gauge or as indicated on drawings. The specification requires compliance with Steel Deck Institute (SDI) 29 Design Manual standards, AWS D1.1 welding code standards, and a maximum vertical deck deflection of 1/240. Installers must have a minimum of three years documented experience in this type of work. All welders employed must possess current AWS certification within the previous 12 months, and manufacturers must provide certificates confirming that products meet or exceed specified requirements.
The specification requires installation in accordance with SDI Manual standards with 1.5-inch minimum bearing on steel supports. Deck fastening shall utilize fusion welds through weld washers at a 36/4 pattern, with mechanical fastening of male/female side laps and sealant application to achieve permanent air seals at joints, laps, ends, and penetrations. All welds, burned areas, and damaged coating must be immediately coated with touch-up primer following installation. Field quality control includes inspection of all welds in accordance with AWS D1.1 standards. The specification references related sections for structural steel framing and general submittal procedures, product handling, storage, and execution requirements as defined in other contract sections.
View the file
Other files
Show 40 more
Latest 50 of 125 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
05 31 23 - STEEL ROOF DECKING
Herbert, Rowland & Grubic, Inc. 05 31 23 - 1 011139.0465
SECTION 05 31 23 - STEEL ROOF DECKING
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Steel roof deck and accessories.
2. Formed steel cant strips, eave strips, and valley strips.
3. Framing for openings up to and including 12 inches.
4. Bearing plates and angles.
B. Related Sections:
1. Section 05 12 00 - Structural Steel Framing.
1.2 REFERENCES
A. ASTM International:
1. ASTM A36/A36M - Standard Specification for Carbon Structural Steel.
2. ASTM A653/A653M - Standard Specification for Steel Sheet, Zinc-Coated
(Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process.
3. ASTM A1008/A1008M - Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Baked Hardenable.
B. American Welding Society:
1. AWS D1.1 - Structural Welding Code - Steel.
C. Steel Deck Institute:
1. SDI 29 - Design Manual for Composite Decks, Form Decks and Roof Decks.
D. SSPC: The Society for Protective Coatings:
1. SSPC Paint 15 - Steel Joist Shop Paint.
1.3 PERFORMANCE REQUIREMENTS
A. Design metal deck in accordance with SDI 29 Design Manual.
B. Calculate to structural working stress design and maximum vertical deck deflection of 1/240.
1.4 SUBMITTALS
A. Section 01 33 00 - Submittal Procedures: Submittal requirements.
B. Shop Drawings: Indicate deck plan, support locations, Projections, openings and reinforcement, pertinent details, and accessories.
C. Product Data: Submit deck profile characteristics and dimensions, structural properties, Herbert, Rowland & Grubic, Inc. 05 31 23 - 2 011139.0465 and finishes.
D. Manufacturer's Installation Instructions: Submit manufacturer's installation instructions.
E. Manufacturer's Certificates: Certify Products meet or exceed specified requirements.
F. Welders Certificates: Certify welders employed on the Work, verifying AWS qualification within previous 12 months.
1.5 QUALIFICATIONS
A. Installer: Company specializing in performing Work of this section with minimum of 3 years documented experience.
1.6 DELIVERY, STORAGE, AND HANDLING
A. Section 01 61 00 - Product Requirements: Product storage and handling requirements.
B. Cut plastic wrap to encourage ventilation.
C. Separate sheets and store deck on dry wood sleepers; slope for positive drainage.
PART 2 - PRODUCTS
2.1 MATERIALS
A. Manufacturers:
1. Cordeck.
2. Roof Deck, Inc.
3. Vulcraft.
4. Substitutions: Section 01 61 00 - Product Requirements.
B. Sheet Steel: ASTM A653, Grade 50 Structural Quality; with G90 galvanized coating.
C. Bearing Plates and Angles: ASTM A36/A36M steel, galvanized.
D. Welding Materials: AWS D1.1.
E. Shop Primer: SSPC Paint 15, Type 1, red oxide. For deck accessories.
F. Touch-Up Primer: Match shop primer.
G. Touch-Up Primer for Galvanized Surfaces: Type II Organic
1. Comply with ASTM A780.
2.2 FABRICATION
A. Metal Deck: Sheet steel, configured as follows:
1. Span Design: Multiple.
2. Minimum Metal Thickness Excluding Finish: 20 gage or as indicated on drawings.
Herbert, Rowland & Grubic, Inc. 05 31 23 - 3 011139.0465
3. Nominal Height: As indicated on contract documents.
4. Formed Sheet Width: Manufacturers maximum standard width.
5. Side Joints: lapped.
B. Weld Washers for 22 gage or thinner:
1. Mild steel, uncoated, ¾ inch outside diameter, 1/8 inch thick.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Section 01 73 00 - Execution Requirements: Coordination and project conditions.
3.2 INSTALLATION
A. Erect metal deck in accordance with SDI Manual.
B. Bear deck on steel supports with 1-1/2 inch minimum bearing. Align and level.
C. Fasten deck to steel support members at ends and intermediate supports with fusion welds through weld washers at 36/4 pattern per SDI or contract documents.
D. Weld in accordance with AWS D1.1.
E. Mechanically fasten male/female side laps.
F. Seal deck joints, laps, ends, and penetrations with sealant to achieve permanent air seal consistent with air barrier system.
G. Install sheet steel closures and angle flashings to close openings between deck and walls, columns, and openings.
H. Install foam flute closures above walls and partitions perpendicular to deck flutes.
I. Position roof sump pans with flange bearing on top surface of deck. Fusion weld at each deck flute.
J. Place metal cant strips in position and fusion weld.
K. Immediately after welding deck and other metal components in position, coat welds, burned areas, and damaged surface coating, with touch-up prime paint.
3.3 FIELD QUALITY CONTROL
A. Welding: Inspect welds in accordance with AWS D1.1.
END OF SECTION
| PART 1 - GENERAL |
| 1.1 SUMMARY |
| A. Section Includes: |
| 1. Steel roof deck and accessories. |
| 2. Formed steel cant strips, eave strips, and valley strips. |
| 3. Framing for openings up to and including 12 inches. |
| 4. Bearing plates and angles. |
| B. Related Sections: |
| 1. Section 05 12 00 - Structural Steel Framing. |
| 1.2 REFERENCES |
| A. ASTM International: |
| 1. ASTM A36/A36M - Standard Specification for Carbon Structural Steel. |
| 2. ASTM A653/A653M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process. |
| 3. ASTM A1008/A1008M - Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Baked Hardenable. |
| B. American Welding Society: |
| 1. AWS D1.1 - Structural Welding Code - Steel. |
| C. Steel Deck Institute: |
| 1. SDI 29 - Design Manual for Composite Decks, Form Decks and Roof Decks. |
| D. SSPC: The Society for Protective Coatings: |
| 1. SSPC Paint 15 - Steel Joist Shop Paint. |
| 1.3 PERFORMANCE REQUIREMENTS |
| A. Design metal deck in accordance with SDI 29 Design Manual. |
| B. Calculate to structural working stress design and maximum vertical deck deflection of 1/240. |
| 1.4 SUBMITTALS |
| A. Section 01 33 00 - Submittal Procedures: Submittal requirements. |
| B. Shop Drawings: Indicate deck plan, support locations, Projections, openings and reinforcement, pertinent details, and accessories. |
| C. Product Data: Submit deck profile characteristics and dimensions, structural properties, and finishes. |
| D. Manufacturer's Installation Instructions: Submit manufacturer's installation instructions. |
| E. Manufacturer's Certificates: Certify Products meet or exceed specified requirements. |
| F. Welders Certificates: Certify welders employed on the Work, verifying AWS qualification within previous 12 months. |
| 1.5 QUALIFICATIONS |
| A. Installer: Company specializing in performing Work of this section with minimum of 3 years documented experience. |
| 1.6 DELIVERY, STORAGE, AND HANDLING |
| A. Section 01 61 00 - Product Requirements: Product storage and handling requirements. |
| B. Cut plastic wrap to encourage ventilation. |
| C. Separate sheets and store deck on dry wood sleepers; slope for positive drainage. |
| PART 2 - PRODUCTS |
| 2.1 MATERIALS |
| A. Manufacturers: |
| 1. Cordeck. |
| 2. Roof Deck, Inc. |
| 3. Vulcraft. |
| 4. Substitutions: Section 01 61 00 - Product Requirements. |
| B. Sheet Steel: ASTM A653, Grade 50 Structural Quality; with G90 galvanized coating. |
| C. Bearing Plates and Angles: ASTM A36/A36M steel, galvanized. |
| D. Welding Materials: AWS D1.1. |
| E. Shop Primer: SSPC Paint 15, Type 1, red oxide. For deck accessories. |
| F. Touch-Up Primer: Match shop primer. |
| G. Touch-Up Primer for Galvanized Surfaces: Type II Organic |
| 1. Comply with ASTM A780. |
| 2.2 FABRICATION |
| A. Metal Deck: Sheet steel, configured as follows: |
| 1. Span Design: Multiple. |
| 2. Minimum Metal Thickness Excluding Finish: 20 gage or as indicated on drawings. |
| 3. Nominal Height: As indicated on contract documents. |
| 4. Formed Sheet Width: Manufacturers maximum standard width. |
| 5. Side Joints: lapped. |
| B. Weld Washers for 22 gage or thinner: |
| 1. Mild steel, uncoated, ¾ inch outside diameter, 1/8 inch thick. |
| PART 3 - EXECUTION |
| 3.1 EXAMINATION |
| A. Section 01 73 00 - Execution Requirements: Coordination and project conditions. |
| 3.2 INSTALLATION |
| A. Erect metal deck in accordance with SDI Manual. |
| B. Bear deck on steel supports with 1-1/2 inch minimum bearing. Align and level. |
| C. Fasten deck to steel support members at ends and intermediate supports with fusion welds through weld washers at 36/4 pattern per SDI or contract documents. |
| D. Weld in accordance with AWS D1.1. |
| E. Mechanically fasten male/female side laps. |
| F. Seal deck joints, laps, ends, and penetrations with sealant to achieve permanent air seal consistent with air barrier system. |
| G. Install sheet steel closures and angle flashings to close openings between deck and walls, columns, and openings. |
| H. Install foam flute closures above walls and partitions perpendicular to deck flutes. |
| I. Position roof sump pans with flange bearing on top surface of deck. Fusion weld at each deck flute. |
| J. Place metal cant strips in position and fusion weld. |
| K. Immediately after welding deck and other metal components in position, coat welds, burned areas, and damaged surface coating, with touch-up prime paint. |
| 3.3 FIELD QUALITY CONTROL |
| A. Welding: Inspect welds in accordance with AWS D1.1. |
File details come from the government source that posted it. Updated .