Construction AF Form 66.pdf

Air Force Form PDF 118 KB Posted

Attached to
BLDG 4868 Additional Electrical Panel for DMAFB
Solicitation number
24QA026
Issued by

About this file

This document is an AF Form 66, which is a Schedule of Material Submittals for a construction project. It outlines the various submittals required from the contractor, including documents such as traffic control plans, air quality permits, as-builts, warranties, and design submittals. The related federal contract opportunity is for the construction of an additional electrical panel at Building 4868 at Davis-Monthan AFB, to be performed on a design-build basis. The contractor shall furnish all labor, equipment, and materials to perform the site survey, design, and construction/installation of the new 200 Amp, 120/208-volt, three phase panel board. The solicitation number is 24QA026, and the site visit is scheduled for July 25, 2024. Proposals are due by July 10, 2024 at 1:00 PM Arizona local time. The contracting agency is the Department of the Air Force Air Combat Command.

View the file

Other versions and copies of AF Form 66

File Revision Posted Attached to
Attachment 2 AF Form 66.pdf Revision not stated REPAIR AC PAVING
AF form 66 Blank.pdf Revision not stated Demo Mini mute sites
Attach 9_AF Form 66 Submittal Register.pdf Revision not stated PKAA Dorm Water Damage Repair (Construction)
AF Form 66-EEPZ260842 Renovate Convert Comm to SAPR B730.xlsx Revision not stated B730 Renovate Convert Comm to SAPR
AF Form 66_EEPZ254664-B972 UOQ.xlsx Revision not stated B972 Renovate UOQ Community Commons
AF Form 66 B268.xlsx Revision not stated B268 Replace STUS Backup Generator
AF Form 66 B730.xlsx Revision not stated B730 - Renovate RM106 for Emergency Operations Center
AF Form 66.xlsx Revision not stated B836 Replace Electrical in Airfield Lighting Vault
AF Form 66 OSI Flooring.xlsx Revision not stated OSI B926 Flooring
EEPZ254660 Repair Control Tower HVAC B1806 - AF Form 66.xlsx Revision not stated B1806 Repair Control Tower HVAC
AF Form 66 Template.xlsx Revision not stated Replace AAS BAK-15 Controls, B2001, B2003
AF Form 66 EEPZ216808 Replace Security Forces Elevator B926.xlsx Revision not stated B926 Replace Security Forces Elevator
WT 17518487 AF Form 66.xlsx Revision not stated Repair Structural Fire Trainer B17903, 17904
AF Form 66.xlsx Revision not stated RENOVATE/CONVERT 50th 49th SQ OPS, B230
AF Form 66.xlsx Revision not stated T-6 Flightline Shacks
AF Form 66 Template.xlsx Revision not stated Replace Fire Alarms, Multi Facility
EEPZ248229 -- AF Form 66.xlsx Revision not stated Repair Kiddie Pool
Atch 2 AF Form 66.pdf Revision not stated Removal of Underground Storage Tank at Launch Facility E-10 (Laramie County, WY)
Attachment 4 - AF Form 66 Submittal Register.pdf Revision not stated Bldg 65 - Renovation of Telephone Office Area, FE Warren AFB, WY AMENDMENT 03
Attachment 7 - AF Form 66.xlsx Revision not stated Replace Chapel Windows B912
Show all 20

Who attaches AF Form 66

State Files
Iowa 1
Massachusetts 1

Other files

File Type Posted
04868-001-001.PDF PDF
AF Form 3052.xlsx XLSX spreadsheet
Contractor Environmental Guide .pdf PDF
Solicitation - FA487724R0019.pdf PDF
DMAFB Design Compatibility Guidelines 2017.pdf PDF
FBNV240023 - Statement of Work - Addl Elec Panel.pdf PDF
Contractor EAL Template.xlsx XLSX spreadsheet
WD - AZ20240040 - 17 May 24.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ROJECT NUMBER : PROJECT TITLE: SOLICITATION/CONTRACT NO :

NO. OF COPIES REQUIRED

Awarded:

Pre-Con:

NTP:

Const. Start:

Const. End:

Finalled:

APPROVED DISAPPROVED

AF Form 103 Job Order Sec 01010, Para 1.3c 1

Affidavits Sec 01010, Para 1.6a 1

Traffic Control Sec 01010, Para 2.1 1

Air Quality Activity Permit Sec 01010, Para 2.5d Env Cont. Guide Sec 3.3 Air Quality

Waste Manifests Sec 01010, Para 2.5h Env Cont. Guide Sec 3.4 Regulated Hazardous Waste

8 Record As-Builts Sec 01010, Para 3.2.2.a 1

Record Disks Sec 01010, Para 3.2.2.b 1

DD 1354

Sec 01010, Para 3.2.2.c.1 1

Warranty / Guarantee Items Sec 01010, Para 3.2.2.c.3 1

AF Form 3064, Sec 01011, Para 1.5.1 1

Design Charrette Submittal Sec 01011, Para 2.12.1 1

50% Design Submittal Sec 01011, Para 2.12.3 1

100% Design Submittal Sec 01011, Para 2.12.5 1

EMS Most Significant Environmental Aspects Awareness Form Env Cont. Guide Sec 3.2 & Appendix E

EMS Awareness Training Env Cont. Guide Sec 3.3 & Appendix F 1

Notice of Termination Env Cont. Guide 3.5 SWPP Plan 1

Contractor to add Submittals required within specifications or as necessary.

SCHEDULE OF MATERIAL SUBMITTALS

TO BE COMPLETED BY PROJECT ENGINEER TO BE COMPLETED BY CONTRACT ADMINISTRATOR

Add Electrical Panel at Building 4868 RescueFBNV 240023

RE

TU

RN

S

US

PE

NS

E

DA

TE

SU

BM

IT

TA

L

NU

MB

ER

S

CO

NT

RA

CT

OR

R

ES

UB

MI

TT

AL

LI

NE

N

UM

BE

R

ITEM OR DESCRIPTION OF ITEM, CONTRACT

REFERENCE, TYPE OF SUBMITTAL

M

AN

UF

AC

TU

RE

R'

S

FI

EL

D

RE

PO

RT

S

C

LO

SE

OU

T

SU

BM

IT

TA

L

O

PE

RA

TI

ON

A

ND

M

AI

NT

EN

AN

CE

M

AN

UA

L

REMARKS

P

RE

CO

NS

TR

UC

TI

ON

S

UB

MI

TT

AL

S

S

HO

P

DR

AW

IN

GS

P

RO

DU

CT

D

AT

A

S

AM

PL

ES

D

ES

IG

N

DA

TE

T

ES

T

RE

PO

RT

S

C

ER

TI

FI

CA

TE

S

M

AN

UF

AC

TU

RE

RS

IN

ST

RU

CT

IO

NS

O

TH

ER

RE

QU

IR

ED

S

UB

MI

SS

IO

N

DA

TE

FI

NA

L

AP

PR

OV

AL

DATE CONTRACTOR NOTIFIED

DA

TE

R

EC

EI

VE

D

IN

C

ON

TR

AC

TI

NG

DA

TE

T O

CI

VI

L

EN

GI

NE

ER

IN

G

AF FORM 66 (Computer Generated) PAGE 1 of 1

AF Form 66

File details come from the government source that posted it. Updated .