This is a Task Assignment (TA) document issued by the State of Florida Department of Environmental Protection (FDEP) to WSP USA, Inc. (formerly Golder Associates USA Inc.) for remediation activities at the Dry Cleaning Depot site located at 1320 West Sunrise Boulevard, Fort Lauderdale, Broward County, Florida. The task assignment is identified as DC026B under Contract Number HW685, with a completion date of June 23, 2023. The project is managed by Ginger Shirah for FDEP and Matt Crews for WSP USA, Inc.
The contract authorizes WSP to conduct soil vapor and groundwater sampling activities followed by preparation of a Remedial Action Plan (RAP) Modification totaling $28,308.43. Subtask 1 (Project Management) is valued at $2,068.43 with deliverables due May 19, 2023. Subtask 2 (Soil Vapor and Groundwater Sampling) is valued at $18,685.13 with field documentation, laboratory reports, and investigation-derived waste manifest due March 17, 2023. Subtask 3 (RAP Modification) is valued at $7,554.87 with deliverables due April 14, 2023. The work includes assessment of a soil vapor extraction system, collection of samples from 15 SVE wells and 10 monitoring wells, laboratory analysis for volatile organic compounds and dissolved gases, microbial analysis through Microbial Insights, and preparation of a RAP Modification incorporating bioaugmentation recommendations. The contract is structured on a fixed unit rate basis with 126 total labor hours allocated across all subtasks.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Funding Information:
Org. Code E.O. Object Code Budget Entity Appropriation
Category Grant # Project # Year Amount
☐ Additional Funding Information attached on separate page.
Rev. 8/26/2020
STATE OF FLORIDA
DEPARTMENT OF ENVIRONMENTAL PROTECTION
Task Assignment This Task Assignment (TA) is entered into between the Parties named below, pursuant to Contract Number: .
1. TA Number: TA Completion Date:
TA Description:
2. Parties State of Florida Department of Environmental Protection
(Department)
Department Project Manager: Department Project Manager Phone:
Contractor Name: (Contractor ) ntractor’st ’s Project Manager: ontractor’s t’s Project Manager Phone:
3. Project Number:
(If different from TA Number)
Project Location(s):
Project Name:
4. As consideration for the services rendered by Contractor under the terms of this TA, the Department shall pay the Contractor on the following bases, up to the Total TA Value as indicated below:
☐ Fixed Price:
☐ Fixed Unit Rate: (Extended Price)
☐ Cost Reimbursement:
Total TA Value:
5. The Parties agree to comply with the terms and conditions of the underlying the Contract, and the following attachments which are hereby incorporated by reference:
Attachment 1:
☐ Additional Attachments (if necessary):
IN WITNESS WHEREOF, this TA shall be effective on the last date signed below.
State of Florida Department of Environmental Protection CONTRACTOR Department Name:
Title:
Secretary or Designee
(Authorized Signature) (Authorized Signature) Date:
☐ Additional signatures attached on separate page.
HW685
DC026B Completion June 23, 2023
This Task Assignment authorizes WSP to conduct RAPMOD activities in accordance with the Scope of Work and Cost Proposal submitted on January 18, 2023.
Ginger Shirah 850-245-8899 Contractor Contractor
Contractor Contractor
Contractor Contractor
Contractor
WSP USA, Inc.
WSP USA, Inc.
Matt Crews 904-363-3430
ERIC_4158
1320 WEST SUNRISE BOULEVARD, FORT LAUDERDALE, BROWARD COUNTY
DRY CLEANING DEPOT
✔ $ 28,308.43
$ 28,308.43
Scope of Work
Matthew Crews, PE
Environmental Engineer
1/20/2023
Crews, Matt (USMC700671) Digitally signed by Crews, Matt (USMC700671) Date: 2023.01.20 15:08:06 -05'00' Kelly Crain Digitally signed by Kelly Crain
Date: 2023.01.20 13:55:54 -05'00'
N/A
Task Assignment Notification/Change Order Deliverables and Invoice Schedule Attachment
WCP TAFORM 04-2017
Contract Number:
Task Assignment #:
Deliverables:
Deliverable Deliverable Due Date
Invoice Schedule:
Requirements for Invoice Submittal Amount to be Invoiced
TOTAL COST
Subtask 2: Field Documentation, Laboratory Report, IDW Manifest via e-mail deliverable 03/17/2023
Subtasks 1 & 3: RAP Modification; Project Management 04/14/2023
Subtask 2: Field Documentation, Laboratory Report, IDW Manifest via e-mail deliverable $ 18,685.13
Subtasks 1 & 3: RAP Modification; Project Management $ 9,623.30
$ 28,308.43
HW685
DC026B
FLORIDA DEPARTMENT OF
Environmental Protection
Bob Martinez Center 2600 Blair Stone Road
Tallahassee, FL 32399-2400
Ron DeSantis Governor
Jeanette Nuñez Lt. Governor
Shawn Hamilton Secretary
To:
From:
Date:
HW685 Contract Negotiation File Dry Cleaning Depot Fort Lauderdale, Broward County
ERIC_ 4158
Ginger Shirah, Project Manager January 19, 2023
Subject: Negotiation Summary
HW685 DC026B
This Task Assignment authorizes Golder to conduct groundwater monitoring activities in accordance with the January 18, 2022, Scope of Work, Cost Estimate, and Bid Documentation.
Subtask 1: Project Management An automatic calculation based upon total direct labor hours determines the labor hours within this subtask.
Subtask 2: Soil Vapor and Groundwater Sampling Activities This subtask includes labor, vehicle, travel, lab, equipment and subcontractor costs for soil vapor and groundwater sampling activities. First, WSP will assess the condition of the SVE system and collect soil vapor samples from each of the 15 individual SVE wells (SVE-1 through SVE-15). WSP proposes to collect groundwater samples from the following 10 wells: MW001R, MW040, MW010R,MW011R, MW014, MW015R, MW038, MW041, MW042, and MW044 which will be analyzed for volatile organic compounds (VOCs) via EPA method 8260B. Monitoring wells MW001R, MW011R, MW038, MW041, MW042, & MW044 will be analyzed for dissolved gases via EPA Method RSK 175.
Monitoring wells MW001R, MW038, & MW041will be analyzed for CENSUS-DNA by Microbial Insights, a specialty laboratory in Knoxville, TN. WSP requested bids for the IDW disposal; Erwin was chosen with the lowest bids
Subtask 3: RAP Modification This subtask includes labor hours associated with preparing a RAP Modification, which will include proposed injection well information, recommended injection procedures, UIC Notice, updated figures and the quarterly Groundwater Monitoring Plan.
The FDEP Project Manager agrees to the scope of work and final cost associated with this Task Assignment. The final cost for this Task Assignment is $28,308.43 with 126 labor hours. A site access agreement has been executed for this source property as verified on 1/19/23.
Printed on recycled paper.
FDEP COST ESTIMATE
Contractor: Golder Associates USA Inc./WSP USA Inc.
Date: 1/18/2023
Task #: DC026B SubTask 1 Project Management SubTask 6
Site: SubTask 2 Soil Vapor and Groundwater Sampling SubTask 7
Activity/Phase: Remediation SubTask 3 RAP Modification SubTask 8
Project Manager: Ginger Shirah SubTask 4 SubTask 9
SubTask 5 SubTask 10
Totals 1 2 3 4 5 6 7 8 9 10
Labor Rate Category
$64.39 Project Manager (MC) 10.7
$0.00 Program Leader - X-14 0 0 0 0 0 0 0 0 0 0
$68.75 Practice Leader - X-13 (JB) 3 0 3 0 0 0 0 0 0 0
$64.39 Senior Consultant - X-12 (MC) 38 8 30 0 0 0 0 0 0 0
$0.00 Senior Sci/Eng - X-11 0 0 0 0 0 0 0 0 0 0
$0.00 Senior Project Sci/Eng - P-10 0 0 0 0 0 0 0 0 0 0
$42.00 Senior Project Sci/Eng - P-10 (BL) 4 0 4 0 0 0 0 0 0 0
$0.00 Senior Project Sci/Eng - P-10 0 0 0 0 0 0 0 0 0 0
$40.37 Project Sci/Eng - P-9 (DM) 34 34 0 0 0 0 0 0 0 0
$36.66 Staff Sci/Eng - P-8 (JS) 4 0 4 0 0 0 0 0 0 0
$33.90 Staff Sci/Eng - P-8 (AS) 2 0 2 0 0 0 0 0 0 0
$30.00 Sci/Eng/Admin - P-7 (TT) 30 30 0 0 0 0 0 0 0 0
$0.00 0 0 0 0 0 0 0 0 0 0
$0.00 0 0 0 0 0 0 0 0 0 0
$0.00 0 0 0 0 0 0 0 0 0 0
$0.00 0 0 0 0 0 0 0 0 0 0
$0.00 0 0 0 0 0 0 0 0 0 0 $0.00 0 0 0 0 0 0 0 0 0 0
$0.00 0 0 0 0 0 0 0 0 0 0
$0.00 0 0 0 0 0 0 0 0 0 0
$0.00 0 0 0 0 0 0 0 0 0 0
$0.00 0 0 0 0 0 0 0 0 0 0
$0.00 0 0 0 0 0 0 0 0 0 0
$0.00 0 0 0 0 0 0 0 0 0 0
$0.00 0 0 0 0 0 0 0 0 0 0
$0.00 0 0 0 0 0 0 0 0 0 0
Total Hours 126 10.7 72.0 43.0 0 0 0 0 0 0 0
Direct Labor $5,998.14 $690.05 $2,787.70 $2,520.39 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Overhead 172.50% $10,346.79 $1,190.34 $4,808.78 $4,347.67 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Gen & Admin 0.00% $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Fringe 0.00% $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Total Labor $16,344.93 $1,880.39 $7,596.48 $6,868.06 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Dry Cleaning Depot
REV: 02/03 CEF GOLDER Page 1
FDEP COST ESTIMATEContractor: Golder Associates USA Inc./WSP USA Inc.
Date: 1/18/2023
Task #: DC026B SubTask 1 Project Management SubTask 6
Site: SubTask 2 Soil Vapor and Groundwater Sampling SubTask 7
Activity/Phase: Remediation SubTask 3 RAP Modification SubTask 8
Project Manager: Ginger Shirah SubTask 4 SubTask 9
SubTask 5 SubTask 10
Totals 1 2 3 4 5 6 7 8 9 10
Dry Cleaning Depot
Travel
Vehicle Rental $360.00 $360.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Mileage Costs $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Air Fare $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Per diem + Hotel $572.00 $572.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Total Travel $932.00 $932.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Subcontractor (Equipment Procurement)
$0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
$0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
$0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
$0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Subcontractor Subtotal $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Procurement Fee $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Total Subcontractor Cost $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Subcontractor (Services Procurement)
Drilling (Conventional) $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Drilling (Non-conventional) $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Mobile Laboratory $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Surveying $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
IDW $110.00 $110.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Utilities $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Utility Location $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Microbial Insights $1,260.00 $1,260.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
$0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
$0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Subcontractor Subtotal $1,370.00 $1,370.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Handling Fee $137.00 $137.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Total Subcontractor Cost $1,507.00 $1,507.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Laboratory
Analytical Costs $4,920.00 $4,920.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Fast Turnaround Charges $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Sample Shipping $600.00 $600.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Total Laboratory $5,520.00 $5,520.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Field Expenses
Personal Protection $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Expendables $120.00 $120.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Equipment (Drilling Related) $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Equipment (Analytical related) $2,150.00 $2,150.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Equipment (IDW related) $100.00 $100.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Equipment (Other) $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Total Field Expenses $2,370.00 $2,370.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Subtotal $26,673.93 $1,880.39 $17,925.48 $6,868.06 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Completion Fee $1,634.50 $188.04 $759.65 $686.81 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
Total Estimated Cost $28,308.43 $2,068.43 $18,685.13 $7,554.87 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00
REV: 02/03 CEF GOLDER Page 2
LEVEL OF EFFORT/EXPENSE WORKSHEET
SITE : Dry Cleaning Depot SUBTASK 2: Soil Vapor and Groundwater Sampling
DATE: 1/18/2023
LABOR CATEGORY *PROVIDE TIME REQUIRED FOR EACH PERSON
STAFF-TITLE WORK DESCRIPTION HOURS
Senior Consultant (M. Crews) 8
Project Sci/Eng (D. McDaniels) 34
Sci/Eng/Admin (T. Tassimbedo) 30
TOTAL LABOR 72.0
VEHICLE TYPE RATE UNIT USEAGE
Truck $120.00 Per Day 3 $360.00
TOTAL VEHICLE $360.00
PER DIEM STAFF RATE UNIT USEAGE
Per Diem D. McDaniels $36.00 Per Day 3 $108.00 Hotel D. McDaniels $89.00 Per Day 2 $178.00
Per Diem T. Tassimbedo $36.00 Per Day 3 $108.00 Hotel T. Tassimbedo $89.00 Per Day 2 $178.00
TOTAL PER DIEM $572.00
SUBCONTRACTOR COSTS
NAME PURPOSE COST
Microbial Insights CENSUS-DNA $420.00 Per Sample 3 $1,260.00 Erwin IDW T&D - Liquids $110.00 Per Drum 1 $110.00
TOTAL $1,370.00
LABORATORY COSTS
PARAMETER RATE # SAMPLES #QAQC
Groundwater Samples Halocarbons 8260 $73.00 10 $730.00 Methane/ethane/ethene RSK175 $180.00 6 $1,080.00 Total VOCs (IDW) PID/Hall Series $110.00 1 $110.00 Sample Shipping Large $150.00 2 $300.00
Soil Vapor Samples VOC Soil Vapor-Full Scan TO-15 $200.00 15 $3,000.00 Sample Shipping Large $150.00 2 $300.00
TOTAL LAB $5,520.00
EQUIPMENT ITEM RATE COSTING UNIT USEAGE TOTALS
Miscellaneous Expendables $40.00 Per Day 3 $120.00 Shallow Groundwater Sampling Kit $290.00 Per Day 2 $580.00
MAGS Investigation Kit $500.00 Per Day 2 $1,000.00 Tedlar Bag $20.00 Per Bag 12 $240.00
Tubing, Poly HDPE $0.30 Per Foot 1,000 $300.00 Tubing, Silicon 3/16 x 3/8 $3.00 Per foot 10 $30.00
Drum, 55-gallon $100.00 Per Drum 1 $100.00
TOTAL EQUIPMENT $2,370.00
Verification of property ownership for site and offsite property owners for access (2 hours).
Prepare and submit field documentation, laboratory report and non-hazardous waste manifest in an email deliverable to the DEP (4 hours). Characterization and waste profile for transportation and disposal of IDW drum (2 hours).
Round trip travel (10 hours). Development of Health and Safety Plan (3 hours). Field event preparation (1 hour). Collect soil vapor samples from 15 SVE wells (SVE-1 through SVE-15).
Collect groundwater samples from 10 monitoring wells: MW001R in the shallow zone of the surficial aquifer; MW040 in the intermediate zone of the surficial aquifer; and MW010R, MW011R, MW014, MW015R, MW038, MW041, MW042, and MW044 in the deep zone of the surficial aquifer. Water levels, instrument calibration, and sampling (10 hours per day x 2 days = 20 hours).
Round trip travel (10 hours). Collect soil vapor samples from 15 SVE wells (SVE-1 through SVE- 15). Collect groundwater samples from 10 monitoring wells: MW001R in the shallow zone of the surficial aquifer; MW040 in the intermediate zone of the surficial aquifer; and MW010R, MW011R, MW014, MW015R, MW038, MW041, MW042, and MW044 in the deep zone of the surficial aquifer. Water levels, instrument calibration, and sampling (10 hours per day x 2 days = 20 hours).
FINAL --7/24/96
LEVEL OF EFFORT/EXPENSE WORKSHEET
SITE : Dry Cleaning Depot SUBTASK 3: RAP Modification
DATE: 1/18/2023
LABOR CATEGORY *PROVIDE TIME REQUIRED FOR EACH PERSON
STAFF-TITLE WORK DESCRIPTION HOURS
Practice Leader (J. Brown) 3
Senior Consultant (M. Crews) 30
Staff Sci/Eng (J. Spengler) 4
Staff Sci/Eng (A. Strayer) 2
Senior Project Sci/Eng (B. Lucero) 4
TOTAL LABOR 43
VEHICLE TYPE RATE UNIT USEAGE
TOTAL VEHICLE $0.00
PER DIEM STAFF RATE UNIT USEAGE
TOTAL PER DIEM $0.00
SUBCONTRACTOR COSTS
NAME PURPOSE COST
TOTAL $0.00
LABORATORY COSTS
PARAMETER RATE # SAMPLES #QAQC
TOTAL LAB $0.00
EQUIPMENT ITEM RATE COSTING UNIT USEAGE TOTALS
TOTAL EQUIPMENT $0.00
Reporting: Formatting tables, document production. Create pdf for OCULUS.
Develop final injection volume and amendment concentrations. Prepare final RAP Modification.
Prepare draft RAP Modification.
Update figures with 2023 groundwater monitoring data and prepare CADD Figures for RAP Modification.
Prepare report tables with 2023 groundwater data and soil vapor analytical results.
FINAL --7/24/96
10515 Research Drive
Knoxville, TN 37932
Phone: (865) 573-8188
Fax: (865) 573-8133
Client: Phone:
Golder Associates USA Inc.
Matt Crews
9428 Baymeadows Road
Cost Proposal
Suite 400 Fax:Jacksonville, FL 32256
Branch: WSP - Jacksonville FL Project: Dry Cleaning Depot
Quote ID: Q202319.0002 Date Quoted: 01/09/2023
WSP Special Pricing
NOTICE: This cost proposal is intended only for the addressee shown above and may contain confidential or privileged information. If the recipient of this material is not the intended recipient or if you have received this in error, please notify
Microbial Insights, Inc. immediately. Thank you for your cooperation.
Client:
Contact: Date Quoted:
Quote ID:
Cost Proposal
Golder Associates USA Inc. Q202319.0002
01/09/2023Matt Crews
Qty.
Sampling Event:
Analysis Per Sample Cost (USD) Extended
Following is a table detailing the per sample cost based on the objectives for this study.
1 Water
CENSUS-DNA (Dehalococcoides--DHC) $330
CENSUS-DNA ( BAV1 Vinyl Chloride Reductase--BVC) $90
CENSUS-DNA ( tceA Reductase--TCE) $0
CENSUS-DNA ( Vinyl Chloride Reductase--VCR) $0
Sub-Total $420.00$420.00
1 Water
QuantArray (QuantArray-Chlor (DNA)) $900
Sub-Total $900.00$900.00
Total of Items $1,320.00
Discount-15% -15% $-198.00
Total After Discounts 1,122.00
Total Event Cost (USD): $1122.00
Notes:
*For all CENSUS (qPCR) analysis the 1st target is at the higher price than each additional target thereafter.
USMC700671
Highlight
USMC700671
Highlight
Important Information
Sample Cancellation Policy
We understand that on rare occasions our clients may want to cancel an order or analysis of individual samples. However, because samples are processed promptly upon receipt, the following cancellation surcharges apply. If cancellation is within 24 hours of sample receipt there will be no charge. If cancellation is between 24 hours up to 3 working days, there will be a 50% surcharge to cover our processing to that point. After 3 working days the full charge will apply. There is a
$25/sample processing fee if samples are submitted on hold and are later canceled.
Sampling Supplies
We will gladly provide upon request at no additional charge the Bio-Flo filters (Laboratory Preferred for groundwater if using a pump), poly bottles or Whirl-Pak bags for soil along with instructions, COC forms (w/duplicate copies) and sampling labels for your convenience and quality assurance.
Any sample collection supplies will be shipped FedEx ground unless expedited shipping is requested.
MI does not cover any international shipping charges. For expedited (2nd day or Overnight) or international shipping, we require client’s FedEx account number prior to shipping.
It is the client’s responsibility to ship samples back to laboratory. MI does not cover any return shipping costs.
Report format and EDD
This quote is for the standard MI report and standard MI EDD (when applicable). Any deviation from the standard report will result in a surcharge.
Requests for a MI Level III data package will entail an additional 15% surcharge. Allow an additional 1 - 2 weeks after the
Standard Report is completed for the Level III data package to be sent.
Requests for a MI Level IV data package will entail an additional 25% surcharge. Allow an additional 1 - 2 weeks after the
Standard Report is completed for the Level IV data package to be sent.
EDD formats different from the standard MI EDD will entail a 5% surcharge. Please inquire to find out the availability of the EDD being requested.
If you need an example of these formats, please contact an MI representative.
Expiration
This quote expires in 60 days from the quote date. Please contact an MI Representative for the updated pricing.
Payment Terms
Standard Payment terms are Net 30.
From: Mongillo, Ralph To: Mongillo, Ralph Subject: RE: IDW soil and groundwater drum pick up at the Capitol Cleaners at 3813 North Monroe Street in Tallahassee, FL
Date: Tuesday, May 24, 2022 9:10:22 AM
From: Erwin Remediation <erwinremediation@gmail.com> Sent: Monday, May 23, 2022 4:14 PM To: Mongillo, Ralph <ralph.mongillo@wsp.com> Subject: Re: IDW soil and groundwater drum pick up at the Capitol Cleaners at 3813 North Monroe Street in Tallahassee, FL
EXTERNAL EMAIL
EXTERNAL EMAIL - We could not verify the authenticity of this message. Please be cautious when clicking on links or opening attachments.
Ralph, I have this on schedule, but we recently had to increase our drum rate by $10.00.
Unfortunately the cost of fuel and disposal has forced our hand on this.
Thank you, Jonathan Erwin Erwin Remediation, Inc.
Office: (850) 292-6511|Email: ErwinRemediation@Gmail.com Erwin Remediation, Inc.|408 Ditmar Street Pensacola, FL 32503 lTWfa4Hgs7pbKl-BT-P365-c108p227-DayTwo-Disclaimer mailto:ralph.mongillo@wsp.com mailto:ralph.mongillo@wsp.com tel:%28850%29%20292-6511 mailto:ErwinRemediation@gmail.com
From: Craig Burns To: Crews, Matt; Morelli, Gene; Neal, Scott; Mongillo, Ralph Subject: Golder Drum Rates update from CLARK Date: Tuesday, May 10, 2022 12:56:33 PM Attachments: image001.png
Golder Drum Rates - 2022.pdf
EXTERNAL EMAIL
EXTERNAL EMAIL - We could not verify the authenticity of this message. Please be cautious when clicking on links or opening attachments.
Gents- See the new line item reflecting a 10% FSC to the drum total invoice. CLARK started to implement April 15.
Call with questions, also always…thank you for your business.
Craig
Please note: a 10% “cost of services surcharge” will be added to the bottom line of all invoices effective April 15, 2022.
Think CLARK!
Craig Burns | Sales / Project Manager | Clark Environmental Inc.
cburns@clarkenv.com | È:863.327.6289 mailto:cburns@clarkenvironmental.com mailto:matt.crews@wsp.com mailto:gene.morelli@wsp.com mailto:scott.neal@wsp.com mailto:ralph.mongillo@wsp.com https://urldefense.proofpoint.com/v2/url?u=https-3A__eur03.safelinks.protection.outlook.com_-3Furl-3Dhttp-253A-252F-252Fwww.clarkenvironmental.com-252F-26data-3D04-257C01-257C-257Ccbc1f417ff8c4337355508d9512e2412-257Cef8a53ea1a1c4189b792c832dcaea568-257C0-257C0-257C637630080879080169-257CUnknown-257CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0-253D-257C1000-26sdata-3Do50wIW3MIyw-252FGoKyrlvbxMIbbP-252BO9gB5TtQqcXHi-252BR0-253D-26reserved-3D0&d=DwMFAg&c=euGZstcaTDllvimEN8b7jXrwqOf-v5A_CdpgnVfiiMM&r=hv7dluAS8UQz_IXXEGLvDVzJ2x4J8uCkF4c8FXTHlTQ&m=Nk5c7G1FQ88ZgxtZwQzwAlNlpfGMEJLPerLkIs92lL0&s=IkqjklDtDzZYWA58IMoE8gCdmyvcKTVe3L1scUIICLc&e= mailto:cburns@clarkenv.com
5/10/22, 12:47 PM Clark Environmental Inc.: Quote Builder quote.clarkenvironmental.com/Quotes/ViewQuote?quoteId=19536 1/2
Quote Number: 19536
QUOTE
QUOTED TO:
QUOTE DATE: 1/1/2022
COMPANY NAME: WSP / Golder QUOTED BY: Craig Burns
PHONE NUMBER:
Ext.
FAX NUMBER:
PROJECT REFERENCE: Drum Trans & Disposal for non-haz materials
CUSTOMER PO:
CONTACT EMAIL:
SITE ADDRESS: TBD
CLARK ENVIRONMENTAL, INC. IS PLEASED TO PROVIDE THE FOLLOWING
COST ESTIMATE FOR
THE SITE/ PROJECT LISTED ABOVE.
DESCRIPTION PRICE QTY. UNIT TOTAL
NON HAZ DRUM DISPOSAL**Soils, Solids, Sludges** $80.00 DRUM $0.00
NON HAZ DRUM DISPOSAL**Liquids, PPE, Pads/Rags** $60.00 DRUM $0.00
TRANSPORTATION: 0-100 miles from CLARK Mulberry FL <6 drums/site - surcharge of $50/site
$30.00 DRUM $0.00
TRANSPORTATION: 101-250 miles from CLARK Mulberry FL <6 drums/site - surcharge of $50/site
$40.00 DRUM $0.00
TRANSPORTATION: 251-400 miles from CLARK Mulberry FL <11 drums/site - surcharge of $200/site
$50.00 DRUM $0.00
Totes T&D is available. CLARK can also deliver new drums to each site if needed :$40 + tax
$0.00 . $0.00
HAZ Drums to be quoted case-by-case $0.00 . $0.00
OPTIONAL LINE ITEMS
***10% FSC applied to the total cost of the invoice*** $0.00 . $0.00
TOTAL REQUIRED ITEMS $0.00
TOTAL OPTIONAL ITEMS $0.00
GRAND TOTAL $0.00
NOTES: Rates apply for FL. Labs and profiles must be approved prior to pick ups.
**Petro Sites required: TCLP 4 metals & TCLP Benzene**Dry Cleaner Sites require 8260 VOH's**PFAS drum rates are the same as the Petro/Drycleaner NonHaz Drums rates T&D.**Haz rates will be quoted case-by-case** Craig Burns
863.327.6289 - cburns@clarkenv.com
Name (print) Title quote.clarkenvironmental.com/Quotes/ViewQuote?quoteId=19536 2/2
Signature Date
CLARK ENVIRONMENTAL, INC. * 755 Prairie Industrial Pkwy. * Mulberry, Florida 33860 Telephone: 863-425-4884 * Fax: 863-425-2854
WWW.ClarkEnvironmental.com quote.clarkenvironmental.com/Quotes/ViewQuote?quoteId=19536 1/2
Quote Number: 19536
QUOTE
QUOTED TO:
QUOTE DATE: 1/1/2022
COMPANY NAME: WSP / Golder QUOTED BY: Craig Burns
PHONE NUMBER:
Ext.
FAX NUMBER:
PROJECT REFERENCE: Drum Trans & Disposal for non-haz materials
CUSTOMER PO:
CONTACT EMAIL:
SITE ADDRESS: TBD
CLARK ENVIRONMENTAL, INC. IS PLEASED TO PROVIDE THE FOLLOWING
COST ESTIMATE FOR
THE SITE/ PROJECT LISTED ABOVE.
DESCRIPTION PRICE QTY. UNIT TOTAL
NON HAZ DRUM DISPOSAL**Soils, Solids, Sludges** $80.00 DRUM $0.00
NON HAZ DRUM DISPOSAL**Liquids, PPE, Pads/Rags** $60.00 DRUM $0.00
TRANSPORTATION: 0-100 miles from CLARK Mulberry FL <6 drums/site - surcharge of $50/site
$30.00 DRUM $0.00
TRANSPORTATION: 101-250 miles from CLARK Mulberry FL <6 drums/site - surcharge of $50/site
$40.00 DRUM $0.00
TRANSPORTATION: 251-400 miles from CLARK Mulberry FL <11 drums/site - surcharge of $200/site
$50.00 DRUM $0.00
Totes T&D is available. CLARK can also deliver new drums to each site if needed :$40 + tax
$0.00 . $0.00
HAZ Drums to be quoted case-by-case $0.00 . $0.00
OPTIONAL LINE ITEMS
***10% FSC applied to the total cost of the invoice*** $0.00 . $0.00
TOTAL REQUIRED ITEMS $0.00
TOTAL OPTIONAL ITEMS $0.00
GRAND TOTAL $0.00
NOTES: Rates apply for FL. Labs and profiles must be approved prior to pick ups.
**Petro Sites required: TCLP 4 metals & TCLP Benzene**Dry Cleaner Sites require 8260 VOH's**PFAS drum rates are the same as the Petro/Drycleaner NonHaz Drums rates T&D.**Haz rates will be quoted case-by-case** Craig Burns
863.327.6289 - cburns@clarkenv.com
Name (print) Title quote.clarkenvironmental.com/Quotes/ViewQuote?quoteId=19536 2/2
Signature Date
CLARK ENVIRONMENTAL, INC. * 755 Prairie Industrial Pkwy. * Mulberry, Florida 33860 Telephone: 863-425-4884 * Fax: 863-425-2854
WWW.ClarkEnvironmental.com
From: Fred Portofe To: Mongillo, Ralph Cc: Madison Rogers; Roger Pragle; Crews, Matt Subject: RE: Investigative Derived Waste Drum Costs for Transportation and Disposal at a Regulated Facility Date: Wednesday, March 9, 2022 9:33:38 AM Attachments: F0152F28A2B5418EBC7A4FD870EC8D28.png
AD282F6C3391468088CDA42829B8E703.png A719914B10184314957B0CA910CA8D14.png F1DF3C4322764E8A9076F1ADFF76864A.png 3409DF389C3B4156BA232DDC85C60E09.png
EXTERNAL EMAIL
EXTERNAL EMAIL - We could not verify the authenticity of this message. Please be cautious when clicking on links or opening attachments.
Ralph
We are not going to provide annual Pricing for the Statewide Contract . After reviewing the scope with my partners and the variability with respect to disposal costing and ever changing fuel costs, we feel we can not bid this work given the current uncertainty in the market. We would be please to bid this work on a casa by case basis.
Fred G. Portofe, PG President of Environmental Services (Professional Geologist in FL, GA, AL, MS, TX, SC, NC, TN, IN, LA, WI and AK) M & D Industrial Services, LLC 5896 Azalea Street Port Orange, Florida 32127 Email: Fportofe@mdindustrialservices.com Website: mdindustrialservices.com Cell: 813-951-1012 Emergencies: 888-307-2790
Sent from Mail for Windows
From: Mongillo, Ralph Sent: Tuesday, March 8, 2022 12:46 PM To: Fred Portofe Cc: Madison Rogers; Roger Pragle; Eddy Mendoza; Crews, Matt mailto:fportofe@mdindustrialservices.com mailto:ralph.mongillo@wsp.com mailto:mrogers@mdindustrialservices.com mailto:rpragle@mdindustrialservices.com mailto:matt.crews@wsp.com mailto:Fportofe@mdindustrialservices.com https://nam10.safelinks.protection.outlook.com/?url=http%3A%2F%2Fmdindustrialservices.com%2F&data=04%7C01%7Cmculbreth%40ectinc.com%7Cbfdc4a6d2ce945e1eaf008d9dcf8eabf%7C911eb1cc54d34d8ca5773bf3ccc8105c%7C0%7C0%7C637783784008834159%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C2000&sdata=ntkZP1OGe7McYRA722JXtcGwkbgN9EEhQtSgBSKqC3E%3D&reserved=0 https://go.microsoft.com/fwlink/?LinkId=550986 mailto:Ralph_Mongillo@golder.com mailto:fportofe@mdindustrialservices.com mailto:mrogers@mdindustrialservices.com mailto:rpragle@mdindustrialservices.com mailto:emendoza@mdindustrialservices.com mailto:Matt_Crews@golder.com
WSP USA Inc.
9428 Baymeadows Road, Suite 400, Jacksonville, Florida, USA 32256
T: +1 904 363-3430 F: +1 904 363-3445 wsp.com
January 18, 2023 Proposal No. 202208346
Ms. Ginger Shirah Florida Department of Environmental Protection Division of Waste Management Waste Site Cleanup Section 2600 Blair Stone Road, MS 4520 Tallahassee, FL 32399-2400
RE: COST PROPOSAL FOR DRY CLEANING DEPOT
RAP MODIFICATION ACTIVITIES
1320 WEST SUNRISE BOULEVARD
FORT LAUDERDALE, BROWARD COUNTY, FLORIDA
FACILITY IDENTIFICATION NUMBER: ERIC_4158
PROPOSED TASK ASSIGNMENT: HW685_HW026B
Dear Ms. Shirah:
WSP USA Inc. (WSP) formally Golder Associates USA Inc. is pleased to provide the Florida Department of Environmental Protection (DEP) with this cost proposal to complete additional sampling activities and prepare a Remedial Action Plan (RAP) Modification for the above-referenced site. This proposal includes a description of the proposed scope of services, level of effort (LOE) sheets for each subtask, and a Cost Estimate Form (CEF) that summarizes the costs of the proposed services. The proposed scope of services is described below.
SUBTASK 1 – PROJECT MANAGEMENT
To facilitate project quality and satisfactory completion of the proposed scope of work, all aspects of this project will be overseen by an experienced project manager. The project manager will be responsible for the schedule, budget, invoicing, project activities, and communications with DEP and the field team. Project management will include coordination of field activities; resource allocation to confirm the work is conducted by qualified professionals in accordance with the project schedule; cost control and tracking of the budget status; and submittal of project invoices in accordance with DEP Drycleaning Solvent Cleanup Program requirements. The project manager will oversee the work so that it is conducted in a manner that is consistent with the requirements of the DEP-approved task assignment.
Ms. Ginger Shirah Proposal No. 202208346
Florida Department of Environmental Protection January 18, 2023
SUBTASK 2 – SOIL VAPOR AND GROUNDWATER SAMPLING
Soil Vapor Sampling AECOM operated a soil vapor extraction (SVE) system at the site from June 2011 to January 2017. Based on the data presented in AECOM’s Year Six Q1&2 Semi-Annual Operation and Maintenance Report, dated March 10, 2017, the SVE system removed approximately 18 pounds of volatile organic compounds (VOCs) during operation. Based on a review of available files in the DEP’s OCULUS database, soil confirmation sampling was not completed at the site following SVE system operation. In addition, soil vapor samples were not collected for laboratory analysis from the individual SVE wells during system operation. The SVE system is still onsite.
WSP proposes to assess the condition of the SVE system and collect soil vapor samples from each of the 15 individual SVE wells (SVE-1 through SVE-15). Before sample collection, WSP will use existing valves and fittings to isolate each SVE well at the system manifold. WSP will then, one at a time, connect each SVE well to Modified Active Gas Sampling (MAGS) equipment to extract and monitor soil vapor from vadose zone soil. The MAGS blower (Fuji Electric Model VFC508P-2T, 2.5 hp, single phase) will be capable of a flow rate of 154 standard cubic feet per minute at a vacuum of 80 inches of water (inches H20) under ideal conditions. A portable generator will supply power to the blower. The connection between the SVE wells and the blower will be made using 2-inch diameter vacuum-rated flexible PVC tubing and Schedule 40 PVC pipe. Vacuum gauges, a flowmeter, a filter, and sample ports will be installed in line.
WSP will run the blower at the highest achievable wellhead vacuum without entraining water for up to 30 minutes at each location. One soil vapor sample will be collected from each well using a Summa Canister (Tedlar bags if Summa Canisters are not available) and submitted to a fixed-base laboratory for VOC analysis using EPA Method
TO-15.
Groundwater Sampling Since the last groundwater injection event in July 2017, tetrachloroethene (PCE) does not appear to have rebounded significantly in the shallow, source area, based on recent groundwater monitoring results at monitoring well MW001R1; however, trichloroethene (TCE), cis-1,2-dichloroethene (cis-1,2-DCE), and vinyl chloride have continued to increase. PCE and TCE concentrations have rebounded significantly in deep, source area monitoring wells MW038 and MW041, indicating that source material is still present. Based on the lithology reported during site assessment activities, these deep zone wells are screened within a sand layer atop the thick layer of hard, vuggy limestone (low permeability) that appears to limit any further vertical migration of contaminants. WSP recommends further enhanced bioremediation injections in the shallow and deep zones in the source area, followed by quarterly groundwater performance monitoring.
Before the injections though, WSP proposes to collect groundwater samples from the following 10 wells: MW001R in the shallow zone of the surficial aquifer; MW040 in the intermediate zone of the surficial aquifer; and MW010R, MW011R, MW014, MW015R, MW038, MW041, MW042, and MW044 in the deep zone of the surficial aquifer. The attached figures (Figures 2, 3, 7, 8, and 9) from the November 2022 Annual Groundwater Monitoring Report, show the monitoring well locations and chlorinated VOC results for the shallow, intermediate, and deep zones of the surficial aquifer.
Before groundwater sampling, the depth to groundwater will be measured at accessible monitoring well using an electronic water level indicator to determine groundwater elevations and flow direction. During the sampling event, the locks and well caps will be inspected for damage or degradation and repaired or replaced as necessary.
Groundwater samples will be collected from the wells in accordance with DEP Standard Operating Procedures (SOPs) for Field Activities (DEP-SOP-001/01) dated January 2017 (effective April 16, 2018). Before collecting the groundwater sample, each well will be purged and field parameters including temperature, pH, specific conductance, dissolved oxygen, turbidity, and oxidation-reduction potential will be monitored. Purge volumes and field parameters will be recorded on field data sheets, and the field monitoring equipment will be calibrated in accordance with the manufacturer’s recommended procedures. The samples will be analyzed as follows:
Sample ID Chlorinated VOCs (Method 8260B)
Dissolved Gases (Method RSK 175)
CENSUS-DNA*
(Microbial Insights)
Shallow Zone
MW001R X X X
Intermediate Zone
MW040 X
Deep Zone
MW010R X
MW011R X X
MW014 X
MW015R X
MW038 X X X
MW041 X X X
MW042 X X
MW044 X X
IDW Total VOCs
*CENSUS-DNA analysis includes Dehalococcoides microbial species and BAV1 Vinyl Chloride Reductase, tceA Reductase, and Vinyl Chloride Reductase functional genes
The groundwater samples to be analyzed for chlorinated VOCs and dissolved gases will be delivered to a Florida Department of Health and National Environmental Laboratory Accreditation Program certified, fixed-base laboratory. The groundwater samples to be analyzed for microbial species and functional genes will be shipped to Microbial Insights in Knoxville, Tennessee. Upon receipt of the laboratory analytical results, WSP will evaluate the constituent concentrations to determine if off-site notification is required.
Investigation Derived Waste WSP will temporarily store the investigation-derived waste (IDW) purge water generated from the groundwater sampling event in a 55-gallon steel drum(s). A waste characterization sample will be collected from the IDW drum(s) for analysis of total VOCs using EPA Method 8260. If the waste characterization sample is acceptable to the disposal subcontractor, the IDW drum(s) will be picked up and transported to a facility for proper disposal. A non-hazardous waste manifest will be provided by the disposal subcontractor upon delivery to the disposal facility.
Interim Deliverable Upon completion of Subtask 2, an e-mail deliverable will be submitted and include copies of the field data sheets, equipment calibration forms, field notes, laboratory analytical report, laboratory chain-of-custody documentation, and non-hazardous waste manifest.
SUBTASK 3 – RAP MODIFICATION
To address the chlorinated VOCs present in groundwater at concentrations above DEP Natural Attenuation Default Concentrations (NADCs), as given in Table 5 of Chapter 62-777 of the FAC, AECOM submitted a Groundwater RAP to DEP in September 2014. The selected remedy was enhanced bioremediation using direct injection wells and EOS® Pro as the carbon source. The DEP approved the Groundwater RAP in January 2015. AECOM completed two injection events as part of the approved RAP (July 2015 and July 2017).
If WSP and DEP agree that bioaugmentation would be beneficial to groundwater remediation, WSP will prepare a Groundwater RAP Modification for the inclusion of bioaugmentation into the injection program. Since there is not a shallow injection well upgradient (based on historical groundwater flow direction) of monitoring well MW001R1, WSP also recommends installing a shallow injection well as part of the IW-J cluster. The RAP Modification will include the following:
▪ A brief discussion of recent site activities.
▪ Proposed injection well construction details for new shallow injection well.
▪ Proposed injection locations and depths.
▪ Recommended dosage concentrations and volumes of carbon source and bioaugmentation amendment.
▪ Amendment injection procedures.
▪ Underground Injection Control Notice.
▪ Proposed injectant and a table summarizing injectant concentrations, volumes, locations/depths.
▪ Figure depicting approximate injection locations.
▪ Quarterly groundwater monitoring plan.
HEALTH AND SAFETY
WSP will prepare a site-specific Health and Safety Plan for the fieldwork. The work will be completed in accordance with WSP’s safety policies and procedures. At a minimum, WSP will wear safety glasses, high-visibility safety vests, and steel-toed boots. A safety job briefing will be conducted before the start of work activities, and anytime the scope of work or site conditions change.
COST AND SCHEDULE
The estimated cost to complete the RAP Modification activities is $28,308.43. WSP will tentatively schedule the soil vapor and groundwater sampling event for February 2023. The LOE/CEF cost sheets are included in Attachment A.
The subcontractor quotes are included in Attachment B. The following table summarizes the proposed costs and deliverable schedule.
Task Proposed Cost Proposed Schedule/Deliverables
Subtask 1 – Project Management $ 2,068.43 May 19, 2023
Subtask 2 – Soil Vapor and Groundwater Sampling
$18,685.13 March 17, 2023 (Field Documentation, Laboratory Report, IDW Manifest via e-mail deliverable)
Subtask 3 – RAP Modification $ 7,554.87 April 14, 2023 (RAP Modification)
Total/Completion Date $28,308.43 June 23, 2023
Please be aware that Golder has been acquired by and is now a Member of the WSP family of companies. Golder remains as a legal entity and is the proposed contracting entity for this proposal. We are in the process of integrating the resources of our companies. Correspondence for this proposal should continue to be addressed to the undersigned.
WSP appreciates the opportunity to provide services to the DEP. Should you require additional information or clarifications, please contact us at (904) 363-3430.
Sincerely, Golder Associates USA Inc.
Matthew C. Crews, PE Jesse C. Brown, PE Senior Lead Consultant, Environmental Engineer Director, Environmental Engineer
MCC/JCB/as
Attachments: Figure 2 – Site Plan
Figure 3 – Site Layout Figure 7 – Groundwater Analytical Results in the Shallow Surficial Aquifer (June 2022) Figure 8 – Groundwater Analytical Results in the Intermediate Surficial Aquifer (June 2022) Figure 9 – Groundwater Analytical Results in the Deep Surficial Aquifer (June 2022)
Attachment A – Level of Effort Sheets / Cost Estimate Form Attachment B – Subcontractor Quotes
G:\Projects\DEP-Drycleaning\Projects\Fort Lauderdale\Dry Cleaning Depot (ERIC_4158) - Ft Lauderdale\DC026B - RAPMOD\Proposal\DC026B - Dry Cleaning Depot RAPMOD Proposal.docx
BCMW004
BCMW005
BCMW006
BCMW007
N W
3t h
TE
R R
AC
E
W SUNRISE BLVD.
N W
3t h
AV
EN
U
E
MW001
MW001R
MW002
MW003
MW004
MW005
MW006
MW012MW009MW010MW011
MW017MW018MW016
MW026
MW001R1
MW007MW008
MW009R
MW010R
MW011R
MW012R
MW013
MW014
MW015R
MW019
MW020
MW021
MW022
MW023
MW025 MW027
MW028
MW029
MW030
MW031
MW032
MW033
MW035MW036
MW037
MW038
MW039
MW040
MW041
MW042
MW043
MW044
MW045
BCMW001
BCMW002
SVE TRAILER
in
31404452.4158 Control No.
31404452-4158A-002a
FIGURE
2022-04-27
BCL
JWS
MCC
JCB
DRY CLEANING DEPOT
1320 WEST SUNRISE BOULEVARD, FT. LAUDERDALE
BROWARD COUNTY, FL
FL. DEPT. OF ENVIRONMENTAL PROTECTION
SITE PLAN
TITLE
PROJECT NO. REV.
PROJECT
CLIENT
CONSULTANT
PREPARED
DESIGNED
REVIEWED
APPROVED
YYYY-MM-DD
IF
T
H
IS
M
EA
SU
R
EM
EN
T D
O
ES
N O
T M
AT
C
H W
H
AT
IS
S
H O
W N
, T H
E
SH
EE
T
SI
ZE
H
AS
B
EE
N M
O D
IF
IE
D F
R O
M : A
N
SI
B
Pa th
\g ol de r.g ds
\c om pl ex da ta
\O ffi ce \J ac ks on vi lle \d ra fti ng \P ro je ct s\
FD
EP
\F D
EP
-D
C \3
2\
_4
8_ D
C _D ep ot
_F tL au de rd al e\
\A ct iv e D ra w in gs
Fi le
N am e:
2-
A-
2a .d w g
SCALE
0 30 60
FEET
LEGEND
1. AERIAL IMAGE TAKEN FROM FLORIDA DEPARTMENT OF
TRANSPORTATION, DATED JANUARY 2021.
2. WELL LOCATIONS SOURCE: AECOM, DATED MARCH, 2021.
3. PROPERTY BOUNDARY TAKEN FROM FLORIDA DEPARTMENT OF
REVENUE.
REFERENCE(S)
FORMER DRY CLEANING DEPOT BUILDING
PARCEL BOUNDARY
BROWARD COUNTY WELLS
MONITORING WELL LOCATION
N W
3t h
TE
R R
AC
E
W SUNRISE BLVD.
N W
3t h
AV
EN
U
E
IRR001
IRR002
MW001
MW001R
MW002
MW003
MW004
MW005
MW006
MW012
MW009 MW010
MW011
MW017MW018MW016
MW001R1
MW007
MW008
MW009R
MW010R
MW011R
MW012R
MW021
MW022
MW023
MW036
MW037 MW038
MW039
MW040
MW041
MW042
MW043
MW044
MW045
MW035
SVE-1
SVE-2
SVE-3
SVE-4
SVE-5
SVE-6
SVE-7
SVE-8
SVE-9
SVE-10
SVE-11
SVE-12
SVE-13
SVE-14
SVE-15
IW-A 30
IW-A 55
IW-A 80
IW-B 30
IW-B 55
IW-B 80
IW-C 30
IW-C 55
IW-C 80
IW-D 30
IW-D 55IW-D 80
IW-E 55
IW-E 80
IW-F 55
IW-F 80
IW-G 55
IW-G 80 IW-H 55
IW-H 80
IW-I 55
IW-I 80
IW-J 55
IW-J 80
IW-K 30
IW-K 55
IW-K 80
BCMW001
BCMW002
PIPING TO
SVE TRAILER
in
31404452.4158 Control No.
31404452-4158A-002
FIGURE
2022-04-27
BCL
JWS
MCC
JCB
DRY CLEANING DEPOT
1320 WEST SUNRISE BOULEVARD, FT. LAUDERDALE
SITE LAYOUT
TITLE
PROJECT NO. REV.
PROJECTCLIENT
CONSULTANT
PREPARED
DESIGNED
REVIEWED
APPROVED
YYYY-MM-DD
IF
T
H
IS
M
EA
SU
R
EM
EN
T D
O
ES
N O
T M
AT
C
H W
H
AT
IS
S
H O
W N
, T H
E
SH
EE
T
SI
ZE
H
AS
B
EE
N M
O D
IF
IE
D F
R O
M : A
N
SI
B
Pa th
\g ol de r.g ds
\c om pl ex da ta
\O ffi ce \J ac ks on vi lle \d ra fti ng \P ro je ct s\
FD
EP
\F D
EP
-D
C \3
2\
_4
8_ D
C _D ep ot
_F tL au de rd al e\
\A ct iv e D ra w in gs
Fi le
N am e:
2-
A-
2.
dw
0 10 20
FEET
LEGEND
1. AERIAL IMAGE TAKEN FROM FLORIDA DEPARTMENT OF
TRANSPORTATION, DATED JANUARY 2021.
2. WELL LOCATIONS SOURCE: AECOM, DATED MARCH, 2021.
3. PROPERTY BOUNDARY TAKEN FROM FLORIDA DEPARTMENT OF
REVENUE.
REFERENCE(S)
SOIL VAPOR EXTRACTION WELL
UNDERGROUND REMEDIATION SYSTEM PIPING
FORMER DRY CLEANING DEPOT BUILDING
PARCEL BOUNDARY
ABANDONED MONITORING WELL
IRRIGATION WELLS
INJECTION WELL POINT
MONITORING WELL LOCATION
2009 SOURCE REMOVAL 6' AND 25' BGS
(617.4 TONS HAZARDOUS)
(957.4 TONS NON-HAZARDOUS)
6 FT-BGS
25 FT-BGS
3t h
TE
R R
AC
E
W SUNRISE BLVD.
MW001R1
MW007
MW031
MW035MW036
SVE TRAILER
in
31404452.4158 Control No.
31404452-4158A-004
FIGURE
2022-04-27
BCL
JWS
MCC
JCB
DRY CLEANING DEPOT
1320 WEST SUNRISE BOULEVARD, FT. LAUDERDALE
GROUNDWATER ANALYTICAL RESULTS IN THE SHALLOW
SURFICIAL AQUIFER
(JUNE 2022)
TITLE
PROJECT NO. REV.
PROJECT
CLIENT
CONSULTANT
PREPARED
DESIGNED
REVIEWED
APPROVED
YYYY-MM-DD
IF
T
H
IS
M
EA
SU
R
EM
EN
T D
O
ES
N O
T M
AT
C
H W
H
AT
IS
S
H O
W N
, T H
E
SH
EE
T
SI
ZE
H
AS
B
EE
N M
O D
IF
IE
D F
R O
M : A
N
SI
B
Pa th
\g ol de r.g ds
\c om pl ex da ta
\O ffi ce \J ac ks on vi lle \d ra fti ng \P ro je ct s\
FD
EP
\F D
EP
-D
C \3
2\
_4
8_ D
C _D ep ot
_F tL au de rd al e\
\A ct iv e D ra w in gs
Fi le
N am e:
2-
A-
4.
0 20 40
FEET
LEGEND
1. AERIAL IMAGE TAKEN FROM FLORIDA DEPARTMENT OF TRANSPORTATION,
DATED JANUARY 2021.
2. WELL LOCATIONS SOURCE: AECOM, DATED MARCH, 2021.
3. PROPERTY BOUNDARY TAKEN FROM FLORIDA DEPARTMENT OF REVENUE.
REFERENCE(S)
SHALLOW MONITORING WELL LOCATION
FORMER DRY CLEANING DEPOT BUILDING
NOTE(S)
MW007 Sample ID 2 - 12 Sample Interval (ft-bgs)
6/20/22 Date Sampled
3 300 Tetrachloroethene (PCE)
3 300 Trichloroethene (TCE)
70 700 Cis-1,2-Dichloroethene (DCE)
100 1,000 Trans-1,2-Dichloroethene (DCE)
1 100 Vinyl Chloride (VC)
7 70 1,1-Dichloroethene
NADCsGCTLs
1. ALL RESULTS ARE REPORTED IN MICROGRAMS PER LITER (µg/L).
2. U - INDICATES THAT THE COMPOUND WAS ANALYZED FOR BUT NOT
DETECTED
3. I- REPORTED VALUE IS BETWEEN THE LABORATORY METHOD DETECTION
LIMIT AND LABORATORY PRACTICAL QUANTITATION LIMIT
4. NA - NOT ANALYZED
5. NS - NOT SAMPLED
6. D - INDICATES SAMPLE WAS DILUTED DURING LAB ANALYSIS
7. BOLD FONT AND YELLOW SHADED CELL INDICATES AN EXCEEDANCE OF
THE APPLICABLE GCTL.
8. BOLD FONT AND BLUE SHADED CELL INDICATES AN EXCEEDANCE OF THE
APPLICABLE NADC.
9. GCTL - GROUNDWATER CLEANUP TARGET LEVEL PER CHAPTER 62-777,
TABLE I OF THE FLORIDA ADMINISTRATIVE CODE (FAC).
10. NADC - NATURAL ATTENUATION DEFAULT CONCENTRATION PER
CHAPTER 62-777, TABLE V OF THE FLORIDA ADMINISTRATIVE CODE (FAC)
11. ft-bgs = FEET BELOW GROUND SURFACE
MW007
2 - 12
07/24/18 05/03/21
0.76 U 0.2 U
0.89 U 0.2 U
0.84 I 0.2 U
0.73 U 0.2 U
0.71 U 0.2 U
0.94 U 0.2 U
MW001R1
5 - 15
07/24/18 05/03/21 06/20/22
0.76 U 7.5 3.5
0.89 U 11 276
120 310 D 1,200
0.73 U 2.8 6.3
110 160 D 250
1.6 15 27.8
MW031
15-20
08/29/07
0.34 U
0.42 U
0.26 U
0.38 U
0.31 U
MW035
5-15
07/23/18 05/03/21 06/21/22
0.76 U 0.59 I 2.6
0.89 U 0.2 U 0.44 I
5.8 0.51 I 0.83 U
0.73 U 0.2 U 0.23 U
0.71 U 0.2 U 0.88 U
0.94 U 0.2 U 0.59 U
MW036
25-30
07/23/18 05/03/21
0.76 U 0.2 U
0.89 U 0.2 U
1.8 0.63 I
0.73 U 0.2 U
1.3 0.31 I
0.94 U 0.2 U
GCTL EXCEEDANCE CONTOUR
NADC EXCEEDANCE CONTOUR
3t h
TE
R R
AC
E
W SUNRISE BLVD.
N W
3t h
AV
EN
U
E
MW008
MW009R
MW013
MW021
MW025
MW027
MW028
MW032
MW037
MW040
in
31404452.4158 Control No.
31404452-4158A-004
FIGURE
2022-04-27
BCL
JWS
MCC
JCB
DRY CLEANING DEPOT
1320 WEST SUNRISE BOULEVARD, FT. LAUDERDALE
GROUNDWATER ANALYTICAL RESULTS IN THE INTERMEDIATE
(JUNE 2022)
TITLE
PROJECT NO. REV.
PROJECTCLIENT
CONSULTANT
PREPARED
DESIGNED
REVIEWED
APPROVED
YYYY-MM-DD
IF
T
H
IS
M
EA
SU
R
EM
EN
T D
O
ES
N O
T M
AT
C
H W
H
AT
IS
S
H O
W N
, T H
E
SH
EE
T
SI
ZE
H
AS
B
EE
N M
O D
IF
IE
D F
R O
M : A
N
SI
B
Pa th
\g ol de r.g ds
\c om pl ex da ta
\O ffi ce \J ac ks on vi lle \d ra fti ng \P ro je ct s\
FD
EP
\F D
EP
-D
C \3
2\
_4
8_ D
C _D ep ot
_F tL au de rd al e\
\A ct iv e D ra w in gs
Fi le
N am e:
2-
A-
4.
FEET
LEGEND
1. AERIAL IMAGE TAKEN FROM FLORIDA DEPARTMENT OF
TRANSPORTATION, DATED JANUARY 2021.
2. WELL LOCATIONS SOURCE: AECOM, DATED MARCH, 2021.
REFERENCE(S)
INTERMEDIATE MONITORING WELL LOCATION
FORMER DRY CLEANING DEPOT BUILDING
NOTE(S)
1. ALL RESULTS ARE REPORTED IN MICROGRAMS PER LITER (µg/L).
2. U - INDICATES THAT THE COMPOUND WAS ANALYZED FOR BUT NOT
DETECTED
3. I- REPORTED VALUE IS BETWEEN THE LABORATORY METHOD DETECTION
LIMIT AND LABORATORY PRACTICAL QUANTITATION LIMIT
4. NA - NOT ANALYZED
5. NS - NOT SAMPLED
6. BOLD FONT AND YELLOW SHADED CELL INDICATES AN EXCEEDANCE OF
THE APPLICABLE GCTL.
7. BOLD FONT AND BLUE SHADED CELL INDICATES AN EXCEEDANCE OF THE
APPLICABLE NADC.
8. GCTL - GROUNDWATER CLEANUP TARGET LEVEL PER CHAPTER 62-777,
TABLE I OF THE FLORIDA ADMINISTRATIVE CODE (FAC).
9. NADC - NATURAL ATTENUATION DEFAULT CONCENTRATION PER CHAPTER
62-777, TABLE V OF THE FLORIDA ADMINISTRATIVE CODE (FAC)
10. ft-bgs = FEET BELOW GROUND SURFACE
NADCsGCTLs
MW013 Sample ID 45 - 50 Sample Interval (ft-bgs)
6/20/22 Date Sampled
3 300 Tetrachloroethene (PCE)
3 300 Trichloroethene (TCE)
70 700 Cis-1,2-Dichloroethene (DCE)
100 1,000 Trans-1,2-Dichloroethene (DCE)
1 100 Vinyl Chloride (VC)
7 70 1,1-Dichloroethene
MW025
45-50
07/24/18
0.76 U
0.89 U
0.53 U
0.73 U
0.71 U
0.94 U
MW013
35-40
06/07/16
0.76 U
0.89 U
0.53 U
0.73 U
0.71 U
0.94 U
MW028
35-40
08/29/07
0.34 U
0.42 U
0.26 U
0.38 U
0.31 U
NM
MW027
45-50
07/24/18 05/04/21
0.76 U 0.2 U
0.89 U 0.2 U
0.53 U 0.2 U
0.73 U 0.2 U
1.1 0.2 U
0.94 U 0.2 U
MW032
35-40
08/29/07
0.34 U
0.42 U
0.26 U
0.38 U
0.31 U
NM
MW021
35-40
07/24/18
0.76 U
0.89 U
0.53 U
0.73 U
0.71 U
0.94 U
MW037
45-50
07/23/18 05/03/21 06/21/22
0.76 U 0.2 U 0.38 U
0.89 U 0.2 U 0.36 U
0.92 I 0.2 U 0.83 U
0.73 U 0.2 U 0.23 U
1.5 1.5 0.88 U
0.94 U 0.2 U 0.59 U
MW040
50-55
03/21/16 06/21/22
0.76 U 0.38 U
0.89 U 0.36 U
0.97 I 7.3
0.73 U 0.23 U
21 2.0
0.94 U 0.59 U
MW009R
35-40
07/23/18 05/03/21
0.76 U 0.2 U
0.89 U 0.2 U
0.53 U 0.2 U
0.73 U 0.2 U
0.71 U 0.2 U
0.94 U 0.2 U
MW008
45-50
07/23/18 05/03/21 06/21/22
0.76 U 0.2 U 0.38 U
0.89 U 0.2 U 0.36 U
1.1 0.2 U 0.83 U
0.73 U 0.2 U 0.23 U
1.8 0.2 U 0.88 U
0.94 U 0.2 U 0.59 U
3t h
TE
R R
AC
E
W SUNRISE BLVD.
MW010R
MW011R
MW012R
MW014
MW015R
MW019
MW020
MW022
MW023
MW029
MW038
MW039
MW041
MW042
MW043
MW044
MW045
SVE TRAILER
in
31404452.4158 Control No.
31404452-4158A-004
FIGURE
2022-04-27
BCL
JWS
MCC
JCB
DRY CLEANING DEPOT
1320 WEST SUNRISE BOULEVARD, FT. LAUDERDALE
GROUNDWATER ANALYTICAL RESULTS IN THE DEEP
(JUNE 2022)
TITLE
PROJECT NO. REV.
PROJECT
CLIENT
CONSULTANT
PREPARED
DESIGNED
REVIEWED
APPROVED
YYYY-MM-DD
IF
T
H
IS
M
EA
SU
R
EM
EN
T D
O
ES
N O
T M
AT
C
H W
H
AT
IS
S
H O
W N
, T H
E
SH
EE
T
SI
ZE
H
AS
B
EE
N M
O D
IF
IE
D F
R O
M : A
N
SI
B
Pa th
\g ol de r.g ds
\c om pl ex da ta
\O ffi ce \J ac ks on vi lle \d ra fti ng \P ro je ct s\
FD
EP
\F D
EP
-D
C \3
2\
_4
8_ D
C _D ep ot
_F tL au de rd al e\
\A ct iv e D ra w in gs
Fi le
N am e:
2-
A-
4.
FEET
LEGEND
1. AERIAL IMAGE TAKEN FROM FLORIDA DEPARTMENT OF
TRANSPORTATION, DATED JANUARY 2021.
2. WELL LOCATIONS SOURCE: AECOM, DATED MARCH, 2021.
REFERENCE(S)
DEEP MONITORING WELL LOCATION
FORMER DRY CLEANING DEPOT BUILDING
NOTE(S)
1. ALL RESULTS ARE REPORTED IN MICROGRAMS PER LITER (µg/L).
2. U - INDICATES THAT THE COMPOUND WAS ANALYZED FOR BUT NOT
DETECTED
3. I- REPORTED VALUE IS BETWEEN THE LABORATORY METHOD DETECTION
LIMIT AND LABORATORY PRACTICAL QUANTITATION LIMIT
4. NA - NOT ANALYZED
5. NS - NOT SAMPLED
6. D - INDICATES SAMPLE WAS DILUTED DURING LAB ANALYSIS
7. BOLD FONT AND YELLOW SHADED CELL INDICATES AN EXCEEDANCE OF
THE APPLICABLE GCTL.
8. BOLD FONT AND BLUE SHADED CELL INDICATES AN EXCEEDANCE OF THE
APPLICABLE NADC.
9. GCTL - GROUNDWATER CLEANUP TARGET LEVEL PER CHAPTER 62-777,
TABLE I OF THE FLORIDA ADMINISTRATIVE CODE (FAC).
10. NADC - NATURAL ATTENUATION DEFAULT CONCENTRATION PER CHAPTER
62-777, TABLE V OF THE FLORIDA ADMINISTRATIVE CODE (FAC)
11. ft-bgs = FEET BELOW GROUND SURFACE
NADCsGCTLs
MW014 Sample ID 65 - 70 Sample Interval (ft-bgs)
6/20/22 Date Sampled
3 300 Tetrachloroethene (PCE)
3 300 Trichloroethene (TCE)
70 700 Cis-1,2-Dichloroethene (DCE)
100 1,000 Trans-1,2-Dichloroethene (DCE)
1 100 Vinyl Chloride (VC)
7 70 1,1-Dichloroethene
MW014
65-70
07/24/18 05/04/21
0.76 U 0.2 U
0.89 U 0.2 U
1.0 0.2 U
0.73 U 0.2 U
4.0 0.81 I
0.94 U 0.2 U
MW015R
75-80
07/24/18 05/04/21
0.76 U 0.2 U
0.89 U 0.2 U
0.53 U 0.26 I
0.73 U 0.2 U
3.1 0.33 I
0.94 U 0.2 U
MW019
65-70
07/24/18 05/04/21
0.76 U 0.2 U
0.89 U 0.2 U
0.53 U 0.2 U
0.73 U 0.2 U
0.71 U 1.4
0.94 U 0.2 U
MW020
75-80
07/24/18 05/04/21 06/20/22
0.76 U 0.2 U 0.38 U
0.89 U 0.2 U 0.36 U
0.53 U 0.2 U 0.83 U
0.73 U 0.2 U 0.23 U
4.2 0.89 I 0.88 U
0.94 U 0.2 U 0.59 U
MW042
75-80
03/04/19 05/03/21 06/21/22
7.6 U 0.2 U 0.38 U
8.9 U 0.2 U 0.36 U
740 0.2 U 0.83 U 62 0.2 U 0.23 U
500 1.2 1.7 15 0.2 U 0.59 U
MW045
75-80
05/03/21 06/21/22
0.2 U 0.38 U
0.2 U 0.36 U
0.2 U 0.83 U
0.2 U 0.23 U
5.2 1.30
0.2 U 0.59 U
MW011R
75-80
07/24/18 05/03/21 06/21/22
0.76 U 0.2 U 38.0 U
0.89 U 0.2 U 36.0 U
1.3 8.3 842
0.73 U 0.2 U 23.0 U
21 100 915
0.94 U 0.2 U 59.0 U
MW010R
65-70
07/23/18 05/03/21 06/21/22
0.76 U 0.2 U 19.0 U
0.89 U 0.43 I 18.0 U
0.53 U 3.4 50.0 I
0.73 U 0.2 U 11.5 U
0.71 U 15 361
0.94 U 0.2 U 29.5 U
MW041
75-80
03/04/19 05/04/21 06/21/22 190 U 2 U,D 2,720 220 U 34 D 3,420 6,600 140 D 10,000 180 U 2 U,D 69.6 I
18,000 3,500 D 7,290 240 U 6.7 I,D 209
MW038
75-80
03/04/19…