33 05 53 - Identification For Utilities Piping and Equipment.pdf
PDF 91 KB Posted
- Attached to
- 2027 Sewer System Improvements Project
- Solicitation number
- Not on record
- Issued by
- Dauphin County, Harveys Lake Borough, Pennsylvania
About this file
This is a technical specification document for identification of utilities piping and equipment related to Capital Region Water's 2027 Sewer System Improvements Project in Harrisburg, Pennsylvania. The specification details requirements for plastic ribbon tape installation above direct-buried utility pipes to ensure proper identification and safety. The document references related sections covering public water utility distribution piping and sanitary sewerage gravity piping, and requires contractors to submit product data, shop drawings including valve charts and schedules, and project record documents identifying actual locations of tagged valves. Quality assurance requirements mandate compliance with ASME A13.1 standards for color scheme identification of piping systems.
The specification establishes product requirements for two types of identification materials. Standard identification tape must be a minimum of 12 inches wide by 5 mils thick with aluminum core for detection, manufactured for direct burial service, and imprinted with "CAUTION BURIED WATER LINE BELOW" or "CAUTION BURIED SEWER LINE BELOW" according to APWA Color-Code standards. Restrained joint marking tape must be a minimum of 2.5 inches wide by 4 mils thick with adhesive backing. Installation requirements specify that identification tape be buried continuously 2 feet above piping, with separate tape placement for multiple pipes in common trenches, while restrained joint marking tape must be adhered directly to pipe surfaces including around fitting and valve bells, with coordination required with trenching and backfilling work per Section 31 23 33.
View the file
Other files
Show 40 more
Latest 50 of 116 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
33 05 53 - Identification for Utilities
Piping and Equipment
1.0 General
1.1 Summary
A. Section Includes:
1. Plastic ribbon tape for placement above direct-buried utility.
B. Related Requirements:
1. Section 33 14 13 - Public Water Utility Distribution Piping: Materials and methods for piping, valves, and appurtenances.
2. Section 33 31 11 – Sanitary Sewerage Gravity Piping: Materials and methods for piping, manholes, and appurtenances.
1.2 Reference Standards
A. ASME A13.1 - Scheme for the Identification of Piping Systems.
1.3 Submittals
A. Section 01 33 00 - Submittal Procedures: Requirements for submittals.
B. Product Data: The Contractor shall submit manufacturer's catalog literature for each product required.
C. Shop Drawings: The Contractor shall submit list of wording, symbols, letter size, and color-coding for mechanical identification and valve chart and schedule, including valve tag number, location, function, and valve manufacturer's name and model number.
1.4 Closeout Submittals
A. Section 01 77 00 - Closeout Procedures: Requirements for closeout procedures.
B. Project Record Documents: The Contractor shall record actual locations of tagged valves; include valve tag numbers.
1.5 Quality Assurance
A. The Contractor shall conform to ASME A13.1 for color scheme for identification of piping systems and accessories.
2.0 Products
2.1 Ribbon Tape
A. Identification Tape:
1. Description:
a. APWA Color-Code standard, continuously printed.
b. Minimum Size: 12 inches wide by five (5) mils thick.
33 05 53 - Identification for Utilities
Piping and Equipment
c. Manufactured with aluminum core to allow for detection.
d. Manufactured for direct burial service.
e. Imprint for water lines: “CAUTION BURIED WATER LINE BELOW” in large letters.
f. Imprint for sewer lines: “CAUTION BURIED SEWER LINE BELOW” in large letters.
B. Restrained Joint Marking Tape:
1. Description:
a. APWA Color-Code standard, continuously printed.
b. Minimum Size: 2-1/2 inches wide by 4 mils thick.
c. Manufactured for direct burial service.
d. Imprint: “RESTRAINED JOINT” in large letters.
e. Adhesive backer.
3.0 Execution
3.1 Preparation
A. Section 01 73 00 - Execution Requirements: Requirements for installation preparation.
B. The Contractor shall degrease and clean surfaces to receive adhesive for identification materials.
3.2 Installation
A. Identification Tape:
a. Continuous; buried 2 feet above piping.
b. If multiple pipes occur in common trench, the Contractor shall locate tape above each pipe.
c. The Contractor shall coordinate with trench Work as specified in Section 31 23 33
– Trenching and Backfilling for Utilities.
B. Restrained Joint Marking Tape:
a. The Contractor shall install according to manufacturer’s installation instructions.
b. The Contractor shall install the joint marking tape by adhering directly to the pipe.
c. The Contractor shall install the marking tape along the entire length of pipe, including around the circumference of the bells of all fittings and valves.
d. The Contractor shall ensure that the pipe is free of frost and moisture along the surface of the pipe receiving the tape.
e. The Contractor shall coordinate the Work of this section with trench Work as specified in Section 31 23 33 – Trenching and Backfilling for Utilities.
END OF SECTION