About this file

This document is a Window Schedule for the US Army Corps of Engineers project at the Watervliet Arsenal in New York, specifically for a 3 Company Fire Station. The schedule provides comprehensive details about window types, glazing specifications, and installation requirements. The window schedule includes five different window types (A through E) with varying sizes, locations (first and second floors), and operations (fixed and double-hung), primarily using aluminum frames. The glazing schedule specifies technical details such as glass types, including insulating glass units, tempered glass, and fire-rated glass, with options for low-E and bird deterrent coatings. Key technical specifications include fire resistance ratings, thermal requirements, and specific mounting details for different wall types, including concrete and CMU wall installations.

View the file

Other files for this federal contract opportunity

Other files attached to WVA Fire Station Construction Acquisition, newest first.
File Type Posted
01 45 00.15 10.pdf PDF
Solicitation Amendment W912DS25RA009_0009(final).pdf PDF
ET601 - TELECOMM RISER DIAGRAM.pdf PDF
Solicitation Amendment W912DS25RA009_0008 (final).pdf PDF
Amendment W912DS25RA0090007.pdf PDF
01 50 00.pdf PDF
Solicitation Amendment W912DS25RA009 0006.pdf PDF
Solicitation Amendment W912DS25RA0090005.pdf PDF
FINAL_GeotechnicalReport_WatervlietArsenal_Rev1 8-7-23.pdf PDF
WVA Fire Station A-602 20250814.pdf PDF
FINAL_GeotechnicalReport_WatervlietArsenal_Rev1 8-7-23.pdf PDF
08 71 00.pdf PDF
MI703.pdf PDF
ET-601 - TELECOMM RISER DIAGRAM.pdf PDF
ES103 - ELECTRICAL - SITE PLAN - POWER -TELECOMMUNICATIONS.pdf PDF
12 24 13.pdf PDF
25-08-11_I-601 and I-602.pdf PDF
09 51 00.pdf PDF
Solicitation Amendment W912DS25RA0090004 SF 30.pdf PDF
WVA Fire Station A-602 20250801.pdf PDF
WVA Fire Station A-507 20250730.pdf PDF
WVA Fire Station A-501 20250730.pdf PDF
Solicitation Amendment W912DS25RA009 0003.pdf PDF
WVA Fire Station A-503 20250730.pdf PDF
WVA Fire Station A-122 20250730.pdf PDF
06 41 16.00 10.pdf PDF
01 45 00.pdf PDF
WVA Fire Station A-121 20250730.pdf PDF
WVA Fire Station A-603 20250801.pdf PDF
WVA Fire Station A-511 20250730.pdf PDF
WVA Fire Station A-510 20250730.pdf PDF
WVA Fire Station A-310 20250730.pdf PDF
WVA Fire Station A-123 20250730.pdf PDF
AHJ Interpretation - FP Quals.pdf PDF
07 21 16.pdf PDF
07 21 13.pdf PDF
Solicitation Amendment W912DS25RA009 0002.pdf PDF
WVA Fire Station JA Simplex Fire Alarm System_sOAS.pdf PDF
WVA Fire Station JA Plymovent Vehicle Exhaust System_sOAS.pdf PDF
W912DS25RA009 Amendment 0001.pdf PDF
Site Visit Photos.pdf PDF
Attendance List 21 July 2025.pdf PDF
CID PACKAGE.pdf PDF
Solicitation - W912DS25RA009(4).pdf PDF
WVA-FIRESTATION_RTA_SPEC_07-11-2025.pdf PDF
WVA Fire Station - Drawings - RTA 20250624.pdf PDF
Show all 46

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TYPE A TYPE CEXTERIOR

6' - 8"

TYPE B

3' - 0"

V A

R

IE

S

3' - 4"

INTERIOR

3' - 0"

TYPE D TYPE E (1 HOUR FIRE RATED)

3' - 4"

ALUM FRAME

RUNNER

TRACK

PARTITION AS

SCHEDULED

BACKER ROD

& SEALANT

(BOTH SIDES)

EQ 0' - 4 1/2" EQ

1/4"

GLAZING

DOUBLE STUDS

AT JAMB

ALUM

FRAME

BACKER ROD &

SEALANT (BOTH

SIDES)

E Q

/2

E Q

PARTITION AS

SCHEDULED

1/4" GLAZING

ALUM FRAME

BACKER ROD &

SEALANT (BOTH

SIDES)

EQ 0' - 4 1/2" EQ

1/4"

GLAZING

PARTITION AS

SCHEDULED

1HR FIRE RATED WINDOW/

FRAME MOUNTED TO CONC.

SILL

UL APPROVED FIRE

RATED SEALANT AND

BACKER ROD

PRECAST CONCRETE SILL

ANCHORED TO CMU WALL

PLYWOOD UNDERLAYMENT

SOLID SURFACE SILL

WALL AS SCHEDULED

1HR FIRE RATED WINDOW/

FRAME MOUNTED TO CMU

WALL

UL APPROVED FIRE RATED

SEALANT AND BACKER ROD

SEALANT

5/8" GYP BOARD ADHERED TO BOND BEAM/

MOUNTED TO CLIP ANGLE

CLIP ANGLE

BOND BEAM LINTEL

WALL AS SCHEDULED

UL APPROVED FIRE RATED SEALANT

AND BACKER ROD

1HR FIRE RATED WINDOW/ FRAME

MOUNTED TO CMU WALL

SEALANT

5/8" GYP BOARD ADHERED TO BOND

BEAM/ MOUNTED TO CLIP ANGLE

CLIP ANGLE

WALL AS SCHEDULED

GLAZING SCHEDULE

TYPE GLAZING TYPE WINDOW LITE GLAZING TYPE EXTERIOR COATINGS FIRE RESISTANCE RATING

STOREFRONT

EXTERIOR PANE GLAZING INTERIOR PANE GLAZING

REMARKS

INSULATING GLASS UNITS (TWO PANE) TEMPERED GLASS TEMPERED GLASS LOW-E/ BIRD DETERENT

EXTERIOR FIXED INSULATING GLASS UNITS (TWO PANE) TEMPERED GLASS TEMPERED GLASS LOW-E

EXTERIOR OPERABLE INSULATING GLASS UNITS (TWO PANE) TEMPERED GLASS TEMPERED GLASS LOW-E

INTERIOR FIXED SINGLE PANE TEMPERED GLASS

INTERIOR FIXED

FIRE RATED

FIRE PROTECTION RATED GLASS FIRE PROTECTION RATED GLASS FIRE PROTECTION RATED GLASS 1 HOUR PER MANUFACTURERS RECOMMENDATIONS

FOUR FOLD

OVERHEAD DOORS

PREASSEMBLED CLEAR GLASS WITHIN

DOOR

PER MANUFACTURERS RECOMMENDATIONSLOW-E/ BIRD DETERENTCLEAR GLASS

ENTRY DOORS PREASSEMBLED DOUBLE PANE CLEAR

INSULATED GLASS WITHIN DOOR

PER MANUFACTURERS RECOMMENDATIONSLOW-ETEMPERED GLASS TEMPERED GLASS

MISC. DOORS

INTERIOR

PREASSEMBLED SINGLE PANE CLEAR

GLASS WITHIN DOOR

PER MANUFACTURERS RECOMMENDATIONSTEMPERED GLASS

*SEE SPECIFICATIONS FOR THERMAL AND SOUNDS ATTENUATION REQUIREMENTS

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

C

U s e rs

\e e n d c m g \D o c u m e n ts

\W V

A -F

S -D

M M

-A -M

D L c g a n le y .r v t

/1

/2

:5

:2

A

M

A-604

W

IN

D O

W S

C H

E D

U L E

W A

T E

R V

L

IE

T A

R S

E N

A L N

Y N

E W

Y O

R K

D

IS

T R

IC

T

F

E D

E R

A L P

L A

Z A

N E

W Y

O R

K N

Y

C .G

A N

L E

Y

C .G

A N

L E

Y

C .N

E W

M A

N

A P

R

IL

W D

S

C

O M

P A

N Y

F

IR

E S

T A

T

IO

N

WINDOW SCHEDULE

Mark Count

R.O.

Level Operation

FRAME DETAILS

Sill Height Remarks (See Notes Below)Width Height Material Head Jamb Window_Sill

A 7 6' - 8" 4' - 0" FIRST FLOOR FIXED ALUMINUM 4 6 4 3' - 7" EXTERIOR

B 3 3' - 4" 4' - 0" FIRST FLOOR FIXED ALUMINUM 4 6 4 3' - 7" EXTERIOR

B 4 3' - 4" 4' - 0" SECOND FLOOR FIXED ALUMINUM 4 6 4 3' - 6" EXTERIOR

C 2 3' - 4" 4' - 0" FIRST FLOOR DOUBLE HUNG ALUMINUM 2 3 1 3' - 7" EXTERIOR

C 17 3' - 4" 4' - 0" SECOND FLOOR DOUBLE HUNG ALUMINUM 2 3 1 3' - 6" EXTERIOR

D 2 3' - 0" 2' - 0" FIRST FLOOR FIXED ALUMINUM 1 2 3 4' - 0" INTERIOR

E 1 3' - 0" 2' - 0" FIRST FLOOR FIXED ALUMINUM 4 6 5 3' - 0" FIRE RATED WINDOW/ FRAME

3" = 1'-0"

INTERIOR WINDOW HEAD DETAIL

3" = 1'-0"

INTERIOR WINDOW JAMB DETAIL

3" = 1'-0"

INTERIOR WINDOW SILL DETAIL

1. REFER TO FLOOR PLANS AND ELEVATIONS FOR LOCATION OF ALL WINDOWS

2. REFER TO SPECIFICATIONS FOR ANCHORING REQUIREMENTS

3. FIELD VERIFY ALL OPENINGS PRIOR TO WINDOW FRABRICATION

4. REFER TO GLAZING SPEC FOR GLASS TYPE AND THICKNESS

5. REFER TO DRAWING A-502 FOR EXTERIOR WINDOW DETAILS

6. BIRD DTERRENT THREAT FACTOR FOR ALL FIXED WINDOWS IS 18 SEE GLAZING

SPEC FOR BIRD DTERRENT FILM REQUIREMENTS

7. UNLESS NOTED OTHERWISE ALL WINDOWS WILL BE ON EXTERIOR WALLS

8. SEE A-503 FOR EXTERIOR WINDOW DETAIL REFERENCES

9. SEE A-503 - A-505 FOR STOREFRONT WINDOW DETAILS IN APPARATUS BAY AND

LOBBY

GENERAL NOTES

3" = 1'-0"

INTERIOR FIRE RATED WINDOW SILL

DETAIL

3" = 1'-0"

INTERIOR FIRE RATED WINDOW HEAD

DETAIL

3" = 1'-0"

INTERIOR FIRE RATED WINDOW JAMB

DETAIL

Sheets
A-604 - WINDOW SCHEDULE

File details come from the government source that posted it. Updated .