This architectural drawing sheet (A-501) provides detailed door installation specifications for a US Army Corps of Engineers project at the Watervliet Arsenal in New York. The document includes nine technical drawings showing exterior and interior door jamb and head details for different wall construction types, including CMU (concrete masonry unit) walls and metal stud walls. Key construction elements include metal studs (3 5/8" and 10"), various insulation types (R-13 mineral wool, R-15 rigid), brick veneer, continuous air barriers, sealants, backer rods, metal flashing, and specific anchoring methods for door frames. The drawing is part of a project for a Company Fire Station, with the solicitation number W912D25S0017, dated April 29, 2025, and prepared by the New York District of the US Army Corps of Engineers.
View the file
Other files for this federal contract opportunity
Show all 46
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5/8" GYPSUM WALL BOARD
3 5/8" METAL STUDS @16" O.C.
CMU BACK UP WALL
SEALANT
BACKER RODS AND SEALANT
DOOR AND FRAME AS SCHEDULED
ANCHORED INTO CMU
CONTINUOUS AIR BARRER
R-13 RIGID INSULATION
MIN. 2" AIR SPACE
BRICK VENEER
DOVETAIL ANCHOR
PRECAST WALL ACCENT/ CONCETE
SILL
3 5/8" DOUBLE METAL STUD
EXTERIOR
INTERIOR
BRICK VENEER
2" MIN. AIR SPACE
R-15 RIGID INSULATION
CMU BACK UP WALL
5/8" GYPSUM WALL BOARD
3 5/8" METAL STUDS 16" O.C.
3 5/8" METAL RUNNER CHANNEL
3 5/8" METAL STUD BOX HEADER
HSS HEAD BEAM (SEE STRUCTURAL
DRAWINGS
DOOR AND FRAME AS SCHEDULED
ANCHORED INTO CMU BOND BEAM
METAL FLASHING
MORTAR NET
WEEPHOLE
VENTILATORS 24" O.C.
DRIP EDGE
BACKER RODS AND SEALANT
0' - 5 1/2"
STEEL ANGLE SHELF
(SEE STRUCTURAL
DRAWINGS)
CONTINUOUS AIR
BARRIER
EXTERIOR INTERIOR
5/8" GYP. WALL BOARD
DOUBLE 10" STUD
SPRAY FOAM INFILL
10" METAL STUDS @16" O.C.
R-13 MINERAL WOOL BATT
INSULATION
R-15 RIGID INSULATION
2" MIN AIR SPACE
BRICK VENEER
PRECAST WALL ACCENT/
SILL
DOVETAIL ANCHORDOOR AND FRAME AS
SCHEDULED MOUNTED TO
DOUBLE STUDS
BACKER RODS AND
SEALANT
EXTERIOR
INTERIOR
5/8" GYP. WALL BOARD
10" METAL STUDS 16" O.C.
R-13 MINERAL WOOL BATT INSULATION
R-15 RIGID INSULATION
2" MIN. AIR SPACE
BRICK VENEER
10" METAL RUNNER CHANNEL
10" METAL STUD BOXED HEADER
METAL FLASHING
MORTAR NET
SPRAY FOAM INSULATION INFILL
WEEP HOLE VENTILATORS @24" O.C.
DRIP EDGE
STRUCTURAL STEEL ANGLE (SEE
STRUCTURAL DRAWINGS)
BACKER RODS AND SEALANT
DOOR AND FRAME AS SCHEDULED
MOUNTED TO BOX HEADER
EXTERIORINTERIOR
2'0 1'6"
SCALE: 1 1/2" = 1'-0"
CONT SEALANT
(BOTH SIDES)
STEEL DOOR
FRAME
DOUBLE STUDS AT
JAMB
FRAME
ANCHOR
PERPENDICULAR
PARTITIONS PER
FLOOR PLANS
4" TYP 2"
/2
/2
V A
R
IE
S
PARTITION AS SCHEDULED
GWB BOTH SIDES
DOOR FRAME
DOOR AS
SCHEDULED
DOUBLE
METAL
STUD HEADER
PART. TYPE PER SCHED.
METAL STUD CAVITY
PER PARTITION TYPE
GWB ONE SIDE,
PLYWD. OTHER SIDE.
SEE PARTITION TYPES
D
P A
R T
T
Y P
E P
E R
S C
H E
D
GWB BOTH SIDES
DOOR
FRAM
E
DOOR AS
SCHEDULED
DOUBLE
METAL
STUD JAMB
METAL STUD CAVITY
PER PARTITION TYPE
GWB ONE SIDE,
PLYWD. OTHER SIDE.
SEE PARTITION
TYPES
1'0 6"3"
SCALE: 3" = 1'-0"
6"0 1" 2" 4"
SCALE: 6" = 1'-0"
GENERAL NOTES
1. * - DIMENSIONS VARY REFER TO DOOR OR WINDOW
SCHEDULE
2. FRAME FINISHES NOTED ON DOOR SCHEDULE
BACKER ROD AND SEALANT
DOOR FRAME ANCHORED TO
BOND BEAM
DOOR AND FRAME AS
SCHEDULED
CMU BOND BEAM
WALL AS SCHEDULED
BACKER ROD AND SEALANT
DOOR FRAME ANCHORED TO
BOND BEAM
DOOR AND FRAME AS
SCHEDULED
WALL AS SCHEDULED
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
C
U s e rs
\e e n d c m g \D o c u m e n ts
\W V
A -F
S -D
M M
-A -M
D L c g a n le y .r v t
/3
/2
:1
:4
P
M
A-501
D O
O R
D E
T A
IL
S
W A
T E
R V
L
IE
T A
R S
E N
A L N
Y N
E W
Y O
R K
D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K N
Y
C .G
A N
L E
Y
C .G
A N
L E
Y
C .G
A N
L E
Y
C .N
E W
M A
N
A P
R
IL
W D
S
C
O M
P A
N Y
F
IR
E S
T A
T
IO
N
1 1/2" = 1'-0"
EXTERIOR DOOR JAMB DETAIL AT CMU
WALL
1 1/2" = 1'-0"
EXTERIOR DOOR HEAD DETAIL AT CMU
WALL
1 1/2" = 1'-0"
EXTERIOR DOOR JAMB DETAIL AT 10"
STUD WALL
1 1/2" = 1'-0"
EXTERIOR DOOR HEAD DETAIL AT 10"
STUD WALL
3" = 1'-0"
JAMB DETAIL
1 1/2" = 1'-0"
INTERIOR DOOR HEAD DETAIL
1 1/2" = 1'-0"
INTERIOR DOOR JAMB DETAIL
1 1/2" = 1'-0"
INTERIOR CMU DOOR HEAD DETAIL
1 1/2" = 1'-0"
INTERIOR CMU JAMB DETAIL
| Sheets |
| A-121 - AIR BARRIER DETAILS |
| A-122 - AIR BARRIER DETAILS |
| A-123 - AIR BARRIER DETAILS |
| A-310 - WALL SECTIONS |
| A-501 - DOOR DETAILS |
| A-503 - APPARATUS BAY DOOR AND WINDOW DETAILS |
| A-507 - ROOF DETAILS |
| A-510 - WALL DETAILS |
| A-511 - LOUVER AND MEP PENETRATION DETAILS |
| G-001 - COVER SHEET |
| G-002 - GENERAL NOTES |
| G-003 - SHEET LIST |
| G-004 - FLOOR AREA CALCULATIONS |
File details come from the government source that posted it. Updated .