06 41 16.00 10.pdf

PDF 61 KB Posted

Attached to
WVA Fire Station Construction Acquisition Federal contract opportunity
Solicitation number
W912DS25RA009
Issued by
Department of the Army Corps of Engineers Engineering District New York

About this file

This document is a detailed technical specification (Section 06 41 16.00 10) for Plastic-Laminate-Clad Architectural Cabinets for a WVA Fire Station project, dated July 29, 2025. The specification provides comprehensive requirements for fabricating and installing custom casework, including base and wall cabinets, drawers, shelving, and countertops. Key technical requirements include using medium density fiberboard (MDF) for most cabinet components, high-pressure decorative laminate (HPDL) surfacing, specific joinery methods, and adherence to premium grade quality standards as defined by NAAWS 3.1.

The document specifies detailed technical parameters for materials, including lumber types, panel products, laminate grades, edge banding, and cabinet hardware. Sustainability is emphasized, with requirements for third-party certifications like UL Greenguard Gold and SCS Indoor Advantage Gold. Installation instructions mandate precise mounting techniques, hardware placement, and fitting tolerances. The specification also includes requirements for finishing, with instructions for filling fastener holes, sanding, and applying coatings, and calls for documentation demonstrating sustainable manufacturing practices and product content.

View the file

Other files for this federal contract opportunity

Other files attached to WVA Fire Station Construction Acquisition, newest first.
File Type Posted
01 45 00.15 10.pdf PDF
ET601 - TELECOMM RISER DIAGRAM.pdf PDF
Solicitation Amendment W912DS25RA009_0009(final).pdf PDF
Solicitation Amendment W912DS25RA009_0008 (final).pdf PDF
Amendment W912DS25RA0090007.pdf PDF
01 50 00.pdf PDF
Solicitation Amendment W912DS25RA009 0006.pdf PDF
Solicitation Amendment W912DS25RA0090005.pdf PDF
FINAL_GeotechnicalReport_WatervlietArsenal_Rev1 8-7-23.pdf PDF
WVA Fire Station A-602 20250814.pdf PDF
FINAL_GeotechnicalReport_WatervlietArsenal_Rev1 8-7-23.pdf PDF
08 71 00.pdf PDF
WVA Fire Station A-604 20250814.pdf PDF
25-08-11_I-601 and I-602.pdf PDF
09 51 00.pdf PDF
Solicitation Amendment W912DS25RA0090004 SF 30.pdf PDF
MI703.pdf PDF
ET-601 - TELECOMM RISER DIAGRAM.pdf PDF
ES103 - ELECTRICAL - SITE PLAN - POWER -TELECOMMUNICATIONS.pdf PDF
12 24 13.pdf PDF
WVA Fire Station A-602 20250801.pdf PDF
WVA Fire Station A-507 20250730.pdf PDF
WVA Fire Station A-501 20250730.pdf PDF
Solicitation Amendment W912DS25RA009 0003.pdf PDF
WVA Fire Station A-603 20250801.pdf PDF
WVA Fire Station A-511 20250730.pdf PDF
WVA Fire Station A-510 20250730.pdf PDF
WVA Fire Station A-310 20250730.pdf PDF
WVA Fire Station A-123 20250730.pdf PDF
AHJ Interpretation - FP Quals.pdf PDF
07 21 16.pdf PDF
07 21 13.pdf PDF
WVA Fire Station A-503 20250730.pdf PDF
WVA Fire Station A-122 20250730.pdf PDF
01 45 00.pdf PDF
WVA Fire Station A-121 20250730.pdf PDF
WVA Fire Station JA Plymovent Vehicle Exhaust System_sOAS.pdf PDF
Solicitation Amendment W912DS25RA009 0002.pdf PDF
WVA Fire Station JA Simplex Fire Alarm System_sOAS.pdf PDF
Attendance List 21 July 2025.pdf PDF
W912DS25RA009 Amendment 0001.pdf PDF
Site Visit Photos.pdf PDF
CID PACKAGE.pdf PDF
Solicitation - W912DS25RA009(4).pdf PDF
WVA-FIRESTATION_RTA_SPEC_07-11-2025.pdf PDF
WVA Fire Station - Drawings - RTA 20250624.pdf PDF
Show all 46

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WVA Fire Station WVAFIRESTATION23 Amendment 003 July 29, 2025

SECTION 06 41 16.00 10

PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS

08/10, CHG 1: 11/18

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)

ANSI A161.2 (1998) Decorative Laminate Countertops, Performance Standards for Fabricated High Pressure

ASTM INTERNATIONAL (ASTM)

ASTM D1037 (2012) Evaluating Properties of Wood-Base Fiber and Particle Panel Materials

ASTM E84 (2020) Standard Test Method for Surface Burning Characteristics of Building Materials

ASTM F547 (202) Standard Terminology of Nails for Use with Wood and Wood-Base Materials

BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)

ANSI/BHMA A156.9 (2020) Cabinet Hardware

COMPOSITE PANEL ASSOCIATION (CPA)

CPA A208.1 (2016) Particleboard

CPA A208.2 (2016) Medium Density Fiberboard (MDF) for Interior Applications

NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)

ANSI/NEMA LD 3 (2005) Standard for High-Pressure Decorative Laminates

SCIENTIFIC CERTIFICATION SYSTEMS (SCS)

SCS SCS Global Services (SCS) Indoor Advantage

U.S. GREEN BUILDING COUNCIL (USGBC)

LEED BD+C (2009; R 2010) Leadership in Energy and Environmental Design(tm) Building Design and Construction (LEED-NC)

SECTION 06 41 16.00 10 Page 1

UL ENVIRONMENT (ULE)

ULE Greenguard UL Greenguard Certification Program

WINDOW AND DOOR MANUFACTURERS ASSOCIATION (WDMA)

ANSI/WDMA I.S.1A (2013) Interior Architectural Wood Flush Doors

WOODWORK INSTITUTE (WI)

NAAWS 3.1 (2017; 2018 Errata Edition) North American Architectural Woodwork Standards

1.2 SYSTEM DESCRIPTION

Work in this section includes laminate clad custom casework cabinets, vanities,and open shelvingas shown on the drawings and as described in this specification. This Section includes high-pressure laminate surfacing and cabinet hardware. Comply with EPA requirements in accordance with Section 01 33 29 SUSTAINABILITY REQUIREMENTS AND REPORTING. Sand smooth and apply a clear finish of polyurethane to all exposed and semi-exposed surfaces, whose finish is not otherwise noted on the drawings or finish schedule. Wood finish may be shop finished or field applied in accordance with Section 09 90 00 PAINTS AND COATINGS.

1.3 SUSTAINABILITY REPORTING

Materials in this technical specification may contribute towards contract compliance with sustainability requirements. See Section 01 33 29 SUSTAINABILITY REQUIREMENTS AND REPORTING for project LEED BD+C local/regional materials, low-emitting materials, recycled content, certified wood and rapidly renewable materials LEED documentation requirements.

1.4 SUBMITTALS

Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are for information only. When used, a code following the "G" classification identifies the office that will review the submittal for the Government.

Submit the following in accordance with Section 01 33 00 SUBMITTAL

PROCEDURES:

SD-02 Shop Drawings

Shop Drawings ; G, DO

Installation ; G, DO

SD-03 Product Data

Wood Materials

Wood Finishes

Finish Schedule

Certification

SECTION 06 41 16.00 10 Page 2

SD-04 Samples

Plastic Laminates ; G, DO

Cabinet Hardware ; G, DO

SD-07 Certificates

Quality Assurance

Laminate Clad Casework

SD-11 Closeout Submittals

LEED Documentation

1.5 QUALITY ASSURANCE

1.5.1 General Requirements

Unless otherwise noted on the drawings, furnish all materials, construction methods, and fabrication conforming to and complying with the premium grade quality standards as outlined in NAAWS 3.1, Section for laminate clad cabinets. These standards apply in lieu of omissions or specific requirements in this specification. Contractors and their personnel engaged in the work must be able to demonstrate successful experience with work of comparable extent, complexity and quality to that shown and specified. Submit a quality control statement which illustrates compliance with and understanding of NAAWS 3.1 requirements, in general, and the specific NAAWS 3.1 requirements provided in this specification.

The quality control statement must also certify a minimum of ten years Contractor's experience in laminate clad casework fabrication and construction. Provide a list of a minimum of five successfully completed projects of a similar scope, size, and complexity in the quality control statement. All Millwork to be constructed in conformance with AWI Standards and have required documentation and labeling.

1.5.2 Mock-ups

Prior to final approval of shop drawings , provide a full-size mock-up of a typical vanity, floor cabinet, wall cabinet, wall shelving, including all components and hardware necessary to illustrate a completed unit with a minimum of one door and one drawer assembly. Include countertops and back splashes where specified. Utilize specified finishes in the patterns and colors as indicated. Upon disapproval, rework or remake the mock-up until approval is secured. Remove rejected units from the jobsite. Approved mock-up may remain as part of the finished work. Submit shop drawings showing all fabricated casework items in plan view, elevations and cross-sections to accurately indicate materials used, details of construction, dimensions, methods of fastening and erection, and installation methods proposed. Clearly cross-reference shop drawing casework items to casework items located on the project drawings. Shop drawings will include a color schedule of all casework items to include all countertop, exposed, and semi-exposed cabinet finishes to include finish material manufacturer, pattern, and color.

SECTION 06 41 16.00 10 Page 3

1.5.3 Sustainable Design Certification

Product must be third party certified in accordance with ULE Greenguard Gold, SCS Scientific Certification Systems Indoor Advantage Gold or equal. Perform certification annually and keep current.

1.6 DELIVERY, STORAGE, AND HANDLING

Casework may be delivered knockdown or fully assembled. Deliver all units to the site in undamaged condition, stored off the ground in fully enclosed areas, and protected from damage. Ventilate the storage area and do not subject to extreme changes in temperature or humidity.

1.7 SEQUENCING AND SCHEDULING

Coordinate work with other trades. Do not install units in any room or space until painting, and ceiling installation are complete within the room where the units are located. Install floor cabinets before finished flooring materials are installed.

PART 2 PRODUCTS

2.1 WOOD MATERIALS

2.1.1 Lumber

a. Provide kiln-dried Grade III framing lumber to dimensions as shown on the drawings. Frame front, where indicated on the drawings, must be nominal 3/4 inch hardwood.

b. Standing or running trim casework components, which are specified to receive a transparent finish, must be hardwood species, plain sawn.

AWI grade must be premium . Indicate location, shape, and dimensions on the drawings.

2.1.2 Panel Products

2.1.2.1 Plywood

Use veneer core hardwood plywood, NAAWS 3.1 Grade AA panels for framing purposes. Indicate nominal thickness of plywood panels in this specification and on the drawings.

2.1.2.2 Particleboard

Provide industrial grade, medium density ( 40 to 50 pounds per cubic foot ), 3/4 inch thick particleboard. Use a moisture-resistant particleboard in grade Type 2-M-2 or 2-M-3 as the substrate for plastic laminate covered countertops backsplashes components as located on the drawings and other areas subjected to moisture. Provide particleboard meeting the minimum standards listed in ASTM D1037 and CPA A208.1 .

2.1.2.3 Medium Density Fiberboard

Medium density fiberboard (MDF) must be an acceptable panel substrate where noted on the drawings. Provide medium density fiberboard meeting the minimum standards listed in CPA A208.2 .

SECTION 06 41 16.00 10 Page 4

2.2 HIGH PRESSURE DECORATIVE LAMINATE (HPDL)

Provide plastic laminates meeting the requirements of ANSI/NEMA LD 3 and ANSI A161.2 for high-pressure decorative laminates. Indicate design, colors, surface finish and texture, and locations on the drawings .

Submit two samples of each plastic laminate pattern and color. Samples less than 5 by 7 inches in size are not acceptable. Provide plastic laminate types and nominal minimum thicknesses for casework components as indicated in the following paragraphs.

2.2.1 Horizontal General Purpose Standard (HGS) Grade

Provide horizontal general purpose standard grade plastic laminate that is

0.048 inches (plus or minus 0.005 inches) in thickness. This laminate grade is intended for horizontal surfaces where postforming is not required. 2.2.2 Vertical General Purpose Standard (VGS) Grade

Provide vertical general purpose standard grade plastic laminate that is

0.028 inches (plus or minus 0.004 inches) in thickness. This laminate grade is intended for exposed exterior vertical surfaces of casework components where postforming is not required.

2.2.3 Horizontal General Purpose Postformable (HGP) Grade

Provide horizontal general purpose postformable grade plastic laminate that is 0.042 inches (plus or minus 0.005 inches) in thickness. This laminate grade is intended for horizontal surfaces where post forming is required.

2.2.4 Vertical General Purpose Postformable (VGP) Grade

Provide vertical general purpose postformable grade plastic laminate that is 0.028 inches (plus or minus 0.004 inches) in thickness. This laminate grade is intended for exposed exterior vertical surfaces of components where postforming is required for curved surfaces.

2.2.5 Horizontal General Purpose Fire Rated (HGF) Grade

Provide horizontal general purpose fire rated grade plastic laminate that is 0.048 inches (plus or minus 0.005 inches) in thickness and a class 1, class A fire rating in accordance with ASTM E84.

2.2.6 Vertical General Purpose Fire Rated (VGF) Grade

Provide vertical general purpose fire rated grade plastic laminate that is

0.028 inches (plus or minus 0.004 inches) in thickness and a class 1, class A fire rating in accordance with ASTM E84.

2.2.7 Cabinet Liner Standard (CLS) Grade

Provide cabinet liner standard grade plastic laminate that is 0.020 inches in thickness. This laminate grade is intended for light duty semi-exposed interior surfaces of casework components.

2.2.8 Backing Sheet (BK) Grade

Undecorated backing sheet grade laminate is formulated specifically to be used on the backside of plastic laminated panel substrates to enhance dimensional stability of the substrate. Backing sheet thickness must be

SECTION 06 41 16.00 10 Page 5

0.020 inches . Provide backing sheets for all laminated casework components where plastic laminate finish is applied to only one surface of the component substrate.

2.3 THERMOSET DECORATIVE OVERLAYS (MELAMINE)

Use thermoset decorative overlays (melamine panels) for casework cabinet interiorand drawer interior surfaces.

2.4 EDGE BANDING

Provide PVC vinyl 0.020 inch thick, edge banding for casework doors and drawer fronts. Material width must be 15/16 inches as indicated on the drawings. Color and pattern must match exposed door and drawer front laminate pattern and color.

2.5 CABINET HARDWARE

Submit one sample of each cabinet hardware item specified to include hinges, pulls, drawer glides, and shelf rests_. Provide hardware conforming to ANSI/BHMA A156.9 , unless otherwise noted, and consisting of the following components:

2.5.1 Door Hinges

Continuous Hinge type , BHMA No. B01492 . Frameless Concealed Hinges, BHMA No. B01612

2.5.2 Cabinet Pulls

Back Mounted Pulls type, BHMA No. B02011.

2.5.3 Drawer Slide

Side mounted Self Closing_Drawer Slide type, BHMA No. B05091 with full extension and a minimum 100 pound load capacity. Include an integral stop to avoid accidental drawer removal.

2.5.4 Adjustable Shelf Support System

Recessed (mortised) metal standards, BHMA No. BO4071, finish: optional.

Support clips for the standards must beclosed type, BHMA No. B04081, finish: optional Multiple holes with metal pin supports.

2.6 FASTENERS

Provide nails, screws, and other suitable fasteners that are the size and type best suited for the purpose and conforming to ASTM F547 where applicable.

2.7 ADHESIVES, CAULKS, AND SEALANTS

2.7.1 Adhesives

Use formula and type of adhesives recommended by AWI. Select adhesives for their ability to provide a durable, permanent bond and take into consideration such factors as materials to be bonded, expansion and contraction, bond strength, fire rating, and moisture resistance. Meet local regulations regarding VOC emissions and off-gassing.

SECTION 06 41 16.00 10 Page 6

2.7.1.1 Wood Joinery

Use Type II for interior use urea-formaldehyde resin formula adhesives to bond wood members. Adhesives must withstand a bond test as described in

ANSI/WDMA I.S.1A .

2.7.1.2 Laminate Adhesive

Adhesive used to join high-pressure decorative laminate to wood must be adhesive consistent with AWI and laminate manufacturer's recommendations.

Adhere PVC edgebanding using a polymer-based hot melt glue.

2.7.2 Caulk

Use clear, 100 percent silicone caulk to fill voids and joints between laminated components and between laminated components and adjacent surfaces.

2.7.3 Sealant

Use sealant recommended by the substrate manufacturer to provide a moisture barrier at sink cutouts and all other locations where unfinished substrate edges may be subjected to moisture.

2.8 WOOD FINISHES

Paint, stain, varnish and perform applications required for laminate clad casework components as indicated in Section 09 90 00 PAINTS AND COATINGS and as indicated in drawings. Indicate color and location on the drawings.

2.9 ACCESSORIES

2.9.1 Grommets

Use plasticmaterial for cutouts with a diameter of2 inches . Indicate locations on the drawings.

2.10 FABRICATION

Verify field measurements as indicated in the shop drawings before fabrication. Accomplish fabrication and assembly of components at the shop site to the maximum extent possible. Meet or exceed the requirements for AWI premium grade unless otherwise indicated in this specification.

Make cabinet style, in accordance with NAAWS 3.1, Section 400-G descriptions, as indicated on the drawings.

2.10.1 Base and Wall Cabinet Case Body

2.10.1.1 Cabinet Components

Use frame members that are glued-together, kiln-dried hardwood lumber.

Brace top corners, bottom corners, and cabinet bottoms with either hardwood blocks or water-resistant glue and nailed in place metal or plastic corner braces. Construct cabinet components from the following materials and thicknesses:

SECTION 06 41 16.00 10 Page 7

2.10.1.1.1 Body Members (Ends, Divisions, Bottoms, and Tops)

3/4 inch medium density fiberboard (MDF) panel product

2.10.1.1.2 Face Frames and Rails

3/4 inch hardwood lumber

2.10.1.1.3 Shelving

3/4 inch medium density fiberboard (MDF) panel product

2.10.1.1.4 Cabinet Backs

1/4 inch medium density fiberboard (MDF) panel product

2.10.1.1.5 Drawer Sides, Backs, and Subfronts

1/2 inch hardwood lumber

2.10.1.1.6 Drawer Bottoms

1/4 inch medium density fiberboard (MDF) panel product

2.10.1.1.7 Door and Drawer Fronts

3/4-inch medium density fiberboard (MDF) panel product

2.10.1.2 Joinery Method for Case Body Members

2.10.1.2.1 Tops, Exposed Ends, and Bottoms

a. Steel "European" assembly screws ( 1-1/2 inch from end, 5 inch on center, fasteners will not be visible on exposed parts).

b. Doweled, glued under pressure (approx. 4 dowels per 12 inches of joint).

c. Stop dado, glued under pressure, and either nailed, stapled or screwed (fasteners will not be visible on exposed parts).

d. Spline or biscuit, glued under pressure.

2.10.1.2.2 Exposed End Corner and Face Frame Attachment

2.10.1.2.2.1 Mitered Joint

lock miter or spline or biscuit, glued under pressure (no visible fasteners)

2.10.1.2.2.2 Non-Mitered Joint (90 degree)

butt joint glued under pressure (no visible fasteners)

2.10.1.2.2.3 Butt Joint

glued and nailed

SECTION 06 41 16.00 10 Page 8

2.10.1.2.3 Cabinet Backs (Wall Hung Cabinets)

Wall hung cabinet backs must not be relied upon to support the full weight of the cabinet and its anticipated load for hanging/mounting purposes.

Method of back joinery and hanging/mounting mechanisms should transfer the load to case body members. Use the following fabrication method:

2.10.1.2.3.1 Full Bound

Full bound, captured in grooves on cabinet sides, top, and bottom.

Cabinet backs for floor standing cabinets must be side bound, captured in grooves; glued and fastened to top and bottom.

2.10.1.2.3.2 Full Overlay

Full overlay, plant-on backs with minimum back thickness of 1/2 inch and minimum No. 12 plated (no case hardened) screws spaced a minimum 3 inches on center. Do not expose edge of back on finished sides. Anchor strips are not required when so attached.

2.10.1.2.3.3 Side Bound

Side bound, captured in groove or rabbetts; glued and fastened.

2.10.1.2.4 Cabinet Backs (Floor Standing Cabinets)

2.10.1.2.4.1 Side Bound

Side bound, captured in grooves; glued and fastened to top and bottom.

2.10.1.2.4.2 Full Overlay

Full overlay, plant-on backs with minimum back thickness of 1/2 inch and minimum No. 12 plated (no case hardened) screws spaced a minimum 3 inches on center. Do not expose edge of back on finished sides. Anchor strips are not required when so attached.

2.10.1.2.4.3 Side Bound with Rabbetts

Side bound, placed in rabbetts; glued and fastened in rabbetts.

2.10.1.2.5 Wall Anchor Strips

Wall Anchor Strips are required for all cabinets with backs less than 1/2 inch thick. Use strips consisting of minimum 1/2 inch thick lumber, minimum 2-1/2 inches width; securely attache to wall side of cabinet back

- top and bottom for wall hung cabinets, top only for floor standing cabinets.

2.10.2 Cabinet Floor Base

Mount floor cabinets on a base constructed of nominal 2 inch thick lumber. Provide base assembly components that are treated lumber. Make finished height for each cabinet base as indicated on the drawings. Make bottom edge of the cabinet door or drawer face extend below the top of the base as indicated on the drawings.

SECTION 06 41 16.00 10 Page 9

2.10.3 Cabinet Door and Drawer Fronts

Fabricate door and drawer fronts from 3/4 inch medium density fiberboard (MDF. Surface all door and drawer front edges with high pressure plastic laminate , color and pattern to match exterior face laminate as indicated on the drawings .

2.10.4 Drawer Assembly

2.10.4.1 Drawer Components

Provide drawer components consisting of a removable drawer front, sides, backs, and bottom. Construct drawer components of the following materials and thicknesses:

2.10.4.1.1 Drawer Sides and Backs For Transparent Finish

1/2 inch thick 7-ply hardwood veneer core plywood (no voids), any species

2.10.4.1.2 Drawer Sides and Backs For Laminate Finish

1/2 inch thick 7-ply hardwood veneer core substrate

2.10.4.1.3 Drawer Sides and Back For Thermoset Decorative Overlay (Melamine) Finish

1/2 inch thick medium density particleboard or MDF fiberboard substrate

2.10.4.1.4 Drawer Bottom

1/4 inch thick veneer core panel product for transparent or plastic laminate finish

2.10.4.2 Drawer Assembly Joinery Method

a. Multiple dovetail (all corners) or French dovetail front/dadoed back, glued under pressure.

b. Doweled, glued under pressure.

c. Lock shoulder, glued and pin nailed.

d. Set bottoms into sides, front, and back, 1/4 inch deep groove with a minimum 3/8 inch standing shoulder.

2.10.5 Shelving

2.10.5.1 General Requirements

Fabricate shelving from 3/4 inch medium density fiberboard (MDF. Finish all shelving top and bottom surfaces with HPDL plastic laminate. Finish shelf edges in a HPDL plastic laminate.

2.10.5.2 Shelf Support System

The shelf support system is as follows:

SECTION 06 41 16.00 10 Page 10

2.10.5.2.1 Recessed (Mortised) Metal Shelf Standards

Mortise standards flush with the finishes surface of the cabinet interior side walls, two per side. Pposition and space standards on the side walls to provide a stable shelf surface that eliminates tipping when shelf front is weighted. Install and adjust standards vertically to provide a level, stable shelf surface when clips are in place.

2.10.5.2.2 Pin Hole Method

Drill holes on the interior surface of the cabinet side walls. Evenly space holes in two vertical columns Space the holes in each column at 1 inch increments starting 6 inches from the cabinet interior bottom and extending to within 6 inches of the top interior surface of the cabinet.

Drill holes to provide a level, stable surface when the shelf is resting on the shelf pins. Coordinate hole diameter with pin insert size to provide a firm, tight fit.

2.10.6 Laminate Application

Apply laminate to substrates following the recommended procedures and instructions of the laminate manufacturer and ANSI/NEMA LD 3 , using tools and devices specifically designed for laminate fabrication and application. Provide a balanced backer sheet (Grade BK) wherever only one surface of the component substrate requires a plastic laminate finish.

Apply required grade of laminate in full uninterrupted sheets consistent with manufactured sizes using one piece for full length only, using adhesives specified herein or as recommended by the manufacturer. Fit corners and joints hairline. Machined flush, file, sand, or buff all laminate edges to remove machine marks and ease (sharp corners removed).

Clean up at easing must be such that no overlap of the member eased is visible. Perform fabrication in conformance to ANSI A161.2 . Provide laminate types and grades for component surfaces as follows unless otherwise indicated on the drawings:

2.10.6.1 Base/Wall Cabinet Case Body

a. Exterior (exposed) surfaces to include exposed and semi-exposed face frame surfaces: HPDL Grade VGS.

b. Interior (semi-exposed) surfaces to include interior back wall, bottom, and side walls: HPDL Grade CLS.

2.10.6.2 Adjustable Shelving

2.10.6.2.1 Top and Bottom Surfaces

HPDL Grade HGS

2.10.6.2.2 All Edges

HPDL Grade VGS

2.10.6.3 Fixed Shelving

2.10.6.3.1 Top and Bottom Surfaces

HPDL Grade HGS

SECTION 06 41 16.00 10 Page 11

2.10.6.3.2 Exposed Edges

HPDL Grade VGS

2.10.6.4 Door, Drawer Fronts, Access Panels

2.10.6.4.1 Exterior (Exposed) and Interior (Semi-Exposed) Faces

HPDL Grade VGS

2.10.6.4.2 Edges

HPDL Grade VGS

2.10.6.5 Drawer Assembly

All interior and exterior surfaces: HPDL Grade CLS.

2.10.6.6 Countertops and Splashes

All exposed and semi-exposed surfaces: HPDL Grade HGS

2.10.6.7 Tolerances

Meet the NAAWS 3.1 premium grade requirements for flushness, flatness, and joint tolerances of laminated surfaces.

2.10.7 Finishing

2.10.7.1 Filling

Do not expose fasteners on laminated surfaces. Make all nails, screws, and other fasteners in non-laminated cabinet components countersunk and fill the holes with wood filler consistent in color with the wood species.

2.10.7.2 Sanding

Prepare all surfaces requiring coatings by sanding with a grit and in a manner that scratches will not show in the final system.

2.10.7.3 Coatings

Types, method of application and location of casework finishes must be in accordance with the finish schedule , drawings and Section 09 90 00 PAINTS AND COATINGS. Paint all cabinet reveals. Submit descriptive data which provides narrative written verification of all types of construction materials and finishes, methods of construction, etc. not clearly illustrated on the submitted shop drawings. Provide written verification of conformance with NAAWS 3.1 for the quality indicated to include materials, tolerances, and types of construction. Both the manufacturer of materials and the fabricator must submit available literature which describes re-cycled product content, operations and processes in place that support efficient use of natural resources, energy efficiency, emissions of ozone depleting chemicals, management of water and operational waste, indoor environmental quality, and other production techniques supporting sustainable design and products.

SECTION 06 41 16.00 10 Page 12

PART 3 EXECUTION

3.1 INSTALLATION

Installation must comply with applicable requirements for NAAWS 3.1 premium quality standards. Install countertops and fabricated assemblies level, plumb, and true to line, in locations shown on the drawings.

Attach and securely anchor cabinets and other laminate clad casework assemblies to the floor and walls with mechanical fasteners that are appropriate for the wall and floor construction.

3.1.1 Anchoring Systems

3.1.1.1 Floor

Utilize a floor anchoring system as detailed on the drawings for base cabinets. Anchoring and mechanical fasteners must not be visible from the finished side of the casework assembly. Attach cabinet assemblies to anchored bases without visible fasteners . Where assembly abuts a wall surface, include a minimum 1/2 inch thick lumber or panel product hanging strip, minimum 2-1/2 inch width; securely attached to the top of the wall side of the cabinet back.

3.1.1.2 Wall

Utilize minimum 1/2 inch thick lumber or panel product hanging strips, minimum 2-1/2 inch width to wall mount cabinet/ vanity ; securely attach to the wall side of the cabinet back, both top and bottom.

3.1.2 Hardware

Install casework hardware in types and locations as indicated on the drawings. Where fully concealed European-style hinges are specified to be used with particleboard or fiberboard doors, use plastic or synthetic insertion dowels to receive 3/16 inch "Euroscrews". The use of wood screws without insertion dowels is prohibited.

3.1.3 Doors, Drawers and Removable Panels

Accomplish the fitting of doors, drawers and removable panels within target fitting tolerances for gaps and flushness in accordance with NAAWS 3.1 premium grade requirements.

3.1.4 Plumbing Fixtures

Install sinks, sink hardware, and other plumbing fixtures in locations as indicated on the drawings and in accordance with Section 22 00 00

PLUMBING, GENERAL PURPOSE.

-- End of Section --

SECTION 06 41 16.00 10 Page 13

06 41 16.00 10 - PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS
PART 1 GENERAL
1.1 REFERENCES
1.2 SYSTEM DESCRIPTION
1.3 SUSTAINABILITY REPORTING
1.4 SUBMITTALS
1.5 QUALITY ASSURANCE
1.5.1 General Requirements
1.5.2 Mock-ups
1.5.3 Sustainable Design Certification
1.6 DELIVERY, STORAGE, AND HANDLING
1.7 SEQUENCING AND SCHEDULING
PART 2 PRODUCTS
2.1 WOOD MATERIALS
2.1.1 Lumber
2.1.2 Panel Products
2.1.2.1 Plywood
2.1.2.2 Particleboard
2.1.2.3 Medium Density Fiberboard
2.2 HIGH PRESSURE DECORATIVE LAMINATE HPDL
2.2.1 Horizontal General Purpose Standard HGS Grade
2.2.2 Vertical General Purpose Standard VGS Grade
2.2.3 Horizontal General Purpose Postformable HGP Grade
2.2.4 Vertical General Purpose Postformable VGP Grade
2.2.5 Horizontal General Purpose Fire Rated HGF Grade
2.2.6 Vertical General Purpose Fire Rated VGF Grade
2.2.7 Cabinet Liner Standard CLS Grade
2.2.8 Backing Sheet BK Grade
2.3 THERMOSET DECORATIVE OVERLAYS MELAMINE
2.4 EDGE BANDING
2.5 CABINET HARDWARE
2.5.1 Door Hinges
2.5.2 Cabinet Pulls
2.5.3 Drawer Slide
2.5.4 Adjustable Shelf Support System
2.6 FASTENERS
2.7 ADHESIVES, CAULKS, AND SEALANTS
2.7.1 Adhesives
2.7.1.1 Wood Joinery
2.7.1.2 Laminate Adhesive
2.7.2 Caulk
2.7.3 Sealant
2.8 WOOD FINISHES
2.9 ACCESSORIES
2.9.1 Grommets
2.10 FABRICATION
2.10.1 Base and Wall Cabinet Case Body
2.10.1.1 Cabinet Components
2.10.1.1.1 Body Members Ends, Divisions, Bottoms, and Tops
2.10.1.1.2 Face Frames and Rails
2.10.1.1.3 Shelving
2.10.1.1.4 Cabinet Backs
2.10.1.1.5 Drawer Sides, Backs, and Subfronts
2.10.1.1.6 Drawer Bottoms
2.10.1.1.7 Door and Drawer Fronts
2.10.1.2 Joinery Method for Case Body Members
2.10.1.2.1 Tops, Exposed Ends, and Bottoms
2.10.1.2.2 Exposed End Corner and Face Frame Attachment
2.10.1.2.2.1 Mitered Joint
2.10.1.2.2.2 Non-Mitered Joint 90 degree
2.10.1.2.2.3 Butt Joint
2.10.1.2.3 Cabinet Backs Wall Hung Cabinets
2.10.1.2.3.1 Full Bound
2.10.1.2.3.2 Full Overlay
2.10.1.2.3.3 Side Bound
2.10.1.2.4 Cabinet Backs Floor Standing Cabinets
2.10.1.2.4.1 Side Bound
2.10.1.2.4.2 Full Overlay
2.10.1.2.4.3 Side Bound with Rabbetts

2.10.1.2.5 Wall Anchor Strips

2.10.2 Cabinet Floor Base
2.10.3 Cabinet Door and Drawer Fronts
2.10.4 Drawer Assembly
2.10.4.1 Drawer Components
2.10.4.1.1 Drawer Sides and Backs For Transparent Finish
2.10.4.1.2 Drawer Sides and Backs For Laminate Finish
2.10.4.1.3 Drawer Sides and Back For Thermoset Decorative Overlay
2.10.4.1.4 Drawer Bottom

2.10.4.2 Drawer Assembly Joinery Method

2.10.5 Shelving
2.10.5.1 General Requirements
2.10.5.2 Shelf Support System
2.10.5.2.1 Recessed Mortised Metal Shelf Standards
2.10.5.2.2 Pin Hole Method
2.10.6 Laminate Application
2.10.6.1 Base/Wall Cabinet Case Body
2.10.6.2 Adjustable Shelving
2.10.6.2.1 Top and Bottom Surfaces
2.10.6.2.2 All Edges
2.10.6.3 Fixed Shelving
2.10.6.3.1 Top and Bottom Surfaces
2.10.6.3.2 Exposed Edges
2.10.6.4 Door, Drawer Fronts, Access Panels
2.10.6.4.1 Exterior Exposed and Interior Semi-Exposed Faces
2.10.6.4.2 Edges
2.10.6.5 Drawer Assembly
2.10.6.6 Countertops and Splashes
2.10.6.7 Tolerances
2.10.7 Finishing
2.10.7.1 Filling
2.10.7.2 Sanding
2.10.7.3 Coatings
PART 3 EXECUTION
3.1 INSTALLATION
3.1.1 Anchoring Systems
3.1.1.1 Floor
3.1.1.2 Wall
3.1.2 Hardware
3.1.3 Doors, Drawers and Removable Panels
3.1.4 Plumbing Fixtures

File details come from the government source that posted it. Updated .