WVA Fire Station A-511 20250730.pdf

PDF 137 KB Posted

Attached to
WVA Fire Station Construction Acquisition Federal contract opportunity
Solicitation number
W912DS25RA009
Issued by
Department of the Army Corps of Engineers Engineering District New York

About this file

This document is a detailed architectural drawing (Sheet A-511) from the US Army Corps of Engineers for the Watervliet Arsenal NY project, specifically focusing on louver and mechanical penetration details for a 3 Company Fire Station. The drawing provides comprehensive technical specifications for louver installations in both masonry and steel-framed walls, including precise cross-sectional views of head, jamb, and sill details. The drawings include multiple layers of construction elements such as brick veneer, insulation (R-15 rigid and R-13 mineral wool batt), air barriers, vapor retarders, gypsum wall board, cold-formed steel studs, and various flashing and sealing components. Additional details cover duct and pipe penetration methods, emphasizing waterproofing, air/moisture barriers, and proper installation techniques to prevent water buildup and ensure structural integrity.

View the file

Other files for this federal contract opportunity

Other files attached to WVA Fire Station Construction Acquisition, newest first.
File Type Posted
01 45 00.15 10.pdf PDF
ET601 - TELECOMM RISER DIAGRAM.pdf PDF
Solicitation Amendment W912DS25RA009_0009(final).pdf PDF
Solicitation Amendment W912DS25RA009_0008 (final).pdf PDF
Amendment W912DS25RA0090007.pdf PDF
01 50 00.pdf PDF
Solicitation Amendment W912DS25RA009 0006.pdf PDF
Solicitation Amendment W912DS25RA0090005.pdf PDF
FINAL_GeotechnicalReport_WatervlietArsenal_Rev1 8-7-23.pdf PDF
WVA Fire Station A-602 20250814.pdf PDF
FINAL_GeotechnicalReport_WatervlietArsenal_Rev1 8-7-23.pdf PDF
08 71 00.pdf PDF
WVA Fire Station A-604 20250814.pdf PDF
25-08-11_I-601 and I-602.pdf PDF
09 51 00.pdf PDF
Solicitation Amendment W912DS25RA0090004 SF 30.pdf PDF
MI703.pdf PDF
ET-601 - TELECOMM RISER DIAGRAM.pdf PDF
ES103 - ELECTRICAL - SITE PLAN - POWER -TELECOMMUNICATIONS.pdf PDF
12 24 13.pdf PDF
WVA Fire Station A-602 20250801.pdf PDF
WVA Fire Station A-507 20250730.pdf PDF
WVA Fire Station A-501 20250730.pdf PDF
Solicitation Amendment W912DS25RA009 0003.pdf PDF
WVA Fire Station A-603 20250801.pdf PDF
WVA Fire Station A-510 20250730.pdf PDF
WVA Fire Station A-310 20250730.pdf PDF
WVA Fire Station A-123 20250730.pdf PDF
AHJ Interpretation - FP Quals.pdf PDF
07 21 16.pdf PDF
07 21 13.pdf PDF
WVA Fire Station A-503 20250730.pdf PDF
WVA Fire Station A-122 20250730.pdf PDF
06 41 16.00 10.pdf PDF
01 45 00.pdf PDF
WVA Fire Station A-121 20250730.pdf PDF
WVA Fire Station JA Plymovent Vehicle Exhaust System_sOAS.pdf PDF
Solicitation Amendment W912DS25RA009 0002.pdf PDF
WVA Fire Station JA Simplex Fire Alarm System_sOAS.pdf PDF
Attendance List 21 July 2025.pdf PDF
W912DS25RA009 Amendment 0001.pdf PDF
Site Visit Photos.pdf PDF
CID PACKAGE.pdf PDF
Solicitation - W912DS25RA009(4).pdf PDF
WVA-FIRESTATION_RTA_SPEC_07-11-2025.pdf PDF
WVA Fire Station - Drawings - RTA 20250624.pdf PDF
Show all 46

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WEEP VENTILATORS

AT 24 INCH OC

LIPPED BRICK

METAL FLASHING

GROUT BARRIER

BACKER ROD AND SEALANT

RUNNER CHANNEL

GYP. WALL BOARD

CONTINUOUS AIR BARRIER/

VAPOR RETARDER

BRICK FACADE

CMU. BOND BEAM- SEE

STRUCT. DRAWINGS

WOOD BLOCKING

ALUMINUM FRAME

COLD FORMED STEEL STUD

LOUVER AS

SCHEDULED

CONTINUIOUS AIR/MOISTURE BARRIER

DOVETAIL ANCHOR AT 16" O.C.

C.M.U.

BACKER RODS AND SEALANT

ALUMINUM FRAME

7/8" FURRING CHANNEL

GYP. WALL BOARD

COLD FORMED STEEL STUDS

LOUVER AS SCHEDULED

SELF ADHERED FLASHING

CONTINUOUS AIR BARRIER

PRESSURE TREATED BLOCKING

SEALANT

COLD FORMED

STEEL STUDS

GYPSUM WALL BOARD

PLYWOOD

SOLID SURFACE

WINDOW SILL

BACKER ROD AND

SEALANT

SEALANT

DRIP EDGE/

FLASHING

ALUMINUM FRAME

LOUVER AS

SCHEDULED

SILL PAN

SELF ADHERING

FLASHING

PRESSURE TREATED

BLOCKING

BRICK VENEER

2" MIN AIR SPACE

R-15 RIGID INSULATION

R-13 MINERAL WOOL BATT

INSULATION

6" METAL SUDS 16" O.C.

6" METAL RUNNER CHANNEL

SPRAY FOAM INSUL.

METAL FLASHING

MORTAR NET

WEEP HOLE VENTILATORS @

24" O.C..

DRIP EDGE

STEEL ANGLE SHELF (SEE

STRUCTURAL DRAWINGS)

BACKER RODS AND SEALANT

5/8" GYP. WALL BOARD

LOUVER AS SCHEDULED

5/8" GYP. WALL BOARD

3 5/8" METAL STUDS @16" O.C.

R-13 MINERAL WOOL BATT

INSULATION

R-15 RIGID INSULATION

2" MIN AIR SPACE

BRICK VENEER

DOVETAIL ANCHOR

BACKER RODS AND

SEALANT

LOUVER AS SCHEDULED

SEALANT

PRESSURE TREATED

BLOCKING

SPRAY FOAM INSUL.

COLD FORMED STEEL STUDS

GYPSUM WALL BOARD

PLYWOOD

SOLID SURFACE

WINDOW SILL

BACKER ROD AND

SEALANT

SEALANT

DRIP EDGE

ALUMINUM FRAME

LOUVER AS

SCHEDULED

SILL PAN

SELF ADHERING FLASHING

PRESSURE TREATED

BLOCKING

SPRAY FOAM INSUL

BACKER ROD

SEALANT

DUCT

DUCT

METAL JACKET

SEALANT

INTERIOR WALL

PIPE SLEEVE

DUCT SLEEVE

EXTERIOR WALL

WATERPROOFING

MEMBRANE

SEALANT

WATERPROOFING

CLAMPING FLANGE

REGLET

COUNTERFLASHING

SEE MECH.

DRAWINGS FOR

DUCT/ PIPE SIZE

*FLASHING WILL BE CONSTRUCTED WITHIN AIR SPACE OF VENEER

TO PREVENT WATER BUILDUP IN ALL SQUARE DUCTS

BACKER ROD

SEALANT

PIPE

PIPE

METAL JACKET

SEALANT

INTERIOR WALL

PIPE SLEEVE

PIPE SLEEVE

EXTERIOR WALL

WATERPROOFING

MEMBRANE

SEALANT

WATERPROOFING

CLAMPING FLANGE

REGLET

COUNTERFLASHING

SEE MECH.

DRAWINGS FOR

PIPE SIZE

*FLASHING WILL BE CONSTRUCTED WITHIN AIR SPACE OF

VENEER TO PREVENT WATER BUILDUP IF MORE THAN 2

SLEEVES CONSTRUCTED WITHIN 6" OF EACHOTHER

2'0 1'6"

SCALE: 1 1/2" = 1'-0"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

C

U s e rs

\e e n d c m g \D o c u m e n ts

\W V

A -F

S -D

M M

-A -M

D L c g a n le y .r v t

/3

/2

:1

:4

P

M

A-511

L O

U V

E R

A N

D M

E P

P E

N E

T R

A T

IO

N

D E

T A

IL

S

W A

T E

R V

L

IE

T A

R S

E N

A L N

Y N

E W

Y O

R K

D

IS

T R

IC

T

F

E D

E R

A L P

L A

Z A

N E

W Y

O R

K N

Y

C .G

A N

L E

Y

C .G

A N

L E

Y

C .G

A N

L E

Y

C .N

E W

M A

N

A P

R

IL

W D

S

C

O M

P A

N Y

F

IR

E S

T A

T

IO

N

1 1/2" = 1'-0"

LOUVER HEAD DETAIL MASONRY WALL

1 1/2" = 1'-0"

LOUVER JAMB DETAIL MASONRY WALL

1 1/2" = 1'-0"

LOUVER SILL DETAIL MASONRY WALL

1 1/2" = 1'-0"

LOUVER HEAD DETAIL STEEL FRAMED

WALL

1 1/2" = 1'-0"

LOUVER JAMB DETAIL STEEL FRAME

WALL

1 1/2" = 1'-0"

LOUVER SILL DETAIL STEEL FRAMED

WALL

N.T.S.

DUCT PENETRATION DETAIL

N.T.S.

PIPE PENETRATION DETAIL

Sheets
A-121 - AIR BARRIER DETAILS
A-122 - AIR BARRIER DETAILS
A-123 - AIR BARRIER DETAILS
A-310 - WALL SECTIONS
A-501 - DOOR DETAILS
A-503 - APPARATUS BAY DOOR AND WINDOW DETAILS
A-507 - ROOF DETAILS
A-510 - WALL DETAILS
A-511 - LOUVER AND MEP PENETRATION DETAILS
G-001 - COVER SHEET
G-002 - GENERAL NOTES
G-003 - SHEET LIST
G-004 - FLOOR AREA CALCULATIONS

File details come from the government source that posted it. Updated .