About this file
This document is a detailed architectural drawing (Sheet A-511) from the US Army Corps of Engineers for the Watervliet Arsenal NY project, specifically focusing on louver and mechanical penetration details for a 3 Company Fire Station. The drawing provides comprehensive technical specifications for louver installations in both masonry and steel-framed walls, including precise cross-sectional views of head, jamb, and sill details. The drawings include multiple layers of construction elements such as brick veneer, insulation (R-15 rigid and R-13 mineral wool batt), air barriers, vapor retarders, gypsum wall board, cold-formed steel studs, and various flashing and sealing components. Additional details cover duct and pipe penetration methods, emphasizing waterproofing, air/moisture barriers, and proper installation techniques to prevent water buildup and ensure structural integrity.
View the file
Other files for this federal contract opportunity
Show all 46
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WEEP VENTILATORS
AT 24 INCH OC
LIPPED BRICK
METAL FLASHING
GROUT BARRIER
BACKER ROD AND SEALANT
RUNNER CHANNEL
GYP. WALL BOARD
CONTINUOUS AIR BARRIER/
VAPOR RETARDER
BRICK FACADE
CMU. BOND BEAM- SEE
STRUCT. DRAWINGS
WOOD BLOCKING
ALUMINUM FRAME
COLD FORMED STEEL STUD
LOUVER AS
SCHEDULED
CONTINUIOUS AIR/MOISTURE BARRIER
DOVETAIL ANCHOR AT 16" O.C.
C.M.U.
BACKER RODS AND SEALANT
ALUMINUM FRAME
7/8" FURRING CHANNEL
GYP. WALL BOARD
COLD FORMED STEEL STUDS
LOUVER AS SCHEDULED
SELF ADHERED FLASHING
CONTINUOUS AIR BARRIER
PRESSURE TREATED BLOCKING
SEALANT
COLD FORMED
STEEL STUDS
GYPSUM WALL BOARD
PLYWOOD
SOLID SURFACE
WINDOW SILL
BACKER ROD AND
SEALANT
SEALANT
DRIP EDGE/
FLASHING
ALUMINUM FRAME
LOUVER AS
SCHEDULED
SILL PAN
SELF ADHERING
FLASHING
PRESSURE TREATED
BLOCKING
BRICK VENEER
2" MIN AIR SPACE
R-15 RIGID INSULATION
R-13 MINERAL WOOL BATT
INSULATION
6" METAL SUDS 16" O.C.
6" METAL RUNNER CHANNEL
SPRAY FOAM INSUL.
METAL FLASHING
MORTAR NET
WEEP HOLE VENTILATORS @
24" O.C..
DRIP EDGE
STEEL ANGLE SHELF (SEE
STRUCTURAL DRAWINGS)
BACKER RODS AND SEALANT
5/8" GYP. WALL BOARD
LOUVER AS SCHEDULED
5/8" GYP. WALL BOARD
3 5/8" METAL STUDS @16" O.C.
R-13 MINERAL WOOL BATT
INSULATION
R-15 RIGID INSULATION
2" MIN AIR SPACE
BRICK VENEER
DOVETAIL ANCHOR
BACKER RODS AND
SEALANT
LOUVER AS SCHEDULED
SEALANT
PRESSURE TREATED
BLOCKING
SPRAY FOAM INSUL.
COLD FORMED STEEL STUDS
GYPSUM WALL BOARD
PLYWOOD
SOLID SURFACE
WINDOW SILL
BACKER ROD AND
SEALANT
SEALANT
DRIP EDGE
ALUMINUM FRAME
LOUVER AS
SCHEDULED
SILL PAN
SELF ADHERING FLASHING
PRESSURE TREATED
BLOCKING
SPRAY FOAM INSUL
BACKER ROD
SEALANT
DUCT
DUCT
METAL JACKET
SEALANT
INTERIOR WALL
PIPE SLEEVE
DUCT SLEEVE
EXTERIOR WALL
WATERPROOFING
MEMBRANE
SEALANT
WATERPROOFING
CLAMPING FLANGE
REGLET
COUNTERFLASHING
SEE MECH.
DRAWINGS FOR
DUCT/ PIPE SIZE
*FLASHING WILL BE CONSTRUCTED WITHIN AIR SPACE OF VENEER
TO PREVENT WATER BUILDUP IN ALL SQUARE DUCTS
BACKER ROD
SEALANT
PIPE
PIPE
METAL JACKET
SEALANT
INTERIOR WALL
PIPE SLEEVE
PIPE SLEEVE
EXTERIOR WALL
WATERPROOFING
MEMBRANE
SEALANT
WATERPROOFING
CLAMPING FLANGE
REGLET
COUNTERFLASHING
SEE MECH.
DRAWINGS FOR
PIPE SIZE
*FLASHING WILL BE CONSTRUCTED WITHIN AIR SPACE OF
VENEER TO PREVENT WATER BUILDUP IF MORE THAN 2
SLEEVES CONSTRUCTED WITHIN 6" OF EACHOTHER
2'0 1'6"
SCALE: 1 1/2" = 1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
F ile
P a th
P lo t D a te
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
C
U s e rs
\e e n d c m g \D o c u m e n ts
\W V
A -F
S -D
M M
-A -M
D L c g a n le y .r v t
/3
/2
:1
:4
P
M
A-511
L O
U V
E R
A N
D M
E P
P E
N E
T R
A T
IO
N
D E
T A
IL
S
W A
T E
R V
L
IE
T A
R S
E N
A L N
Y N
E W
Y O
R K
D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K N
Y
C .G
A N
L E
Y
C .G
A N
L E
Y
C .G
A N
L E
Y
C .N
E W
M A
N
A P
R
IL
W D
S
C
O M
P A
N Y
F
IR
E S
T A
T
IO
N
1 1/2" = 1'-0"
LOUVER HEAD DETAIL MASONRY WALL
1 1/2" = 1'-0"
LOUVER JAMB DETAIL MASONRY WALL
1 1/2" = 1'-0"
LOUVER SILL DETAIL MASONRY WALL
1 1/2" = 1'-0"
LOUVER HEAD DETAIL STEEL FRAMED
WALL
1 1/2" = 1'-0"
LOUVER JAMB DETAIL STEEL FRAME
WALL
1 1/2" = 1'-0"
LOUVER SILL DETAIL STEEL FRAMED
WALL
N.T.S.
DUCT PENETRATION DETAIL
N.T.S.
PIPE PENETRATION DETAIL
| Sheets |
| A-121 - AIR BARRIER DETAILS |
| A-122 - AIR BARRIER DETAILS |
| A-123 - AIR BARRIER DETAILS |
| A-310 - WALL SECTIONS |
| A-501 - DOOR DETAILS |
| A-503 - APPARATUS BAY DOOR AND WINDOW DETAILS |
| A-507 - ROOF DETAILS |
| A-510 - WALL DETAILS |
| A-511 - LOUVER AND MEP PENETRATION DETAILS |
| G-001 - COVER SHEET |
| G-002 - GENERAL NOTES |
| G-003 - SHEET LIST |
| G-004 - FLOOR AREA CALCULATIONS |