About this file

This document is a technical drawing (Sheet A-121) from the US Army Corps of Engineers detailing air barrier installation details for a new fire station project at Watervliet Arsenal in New York. The architectural drawing provides five specific roof eave and wall intersection details at 1 1/2" = 1'-0" scale, illustrating the precise layering and sealing techniques for air barrier systems. Key components include continuous fluid-applied air barriers, spray foam air barriers, rigid insulation, sealants, backer rods, and storefront windows. The drawing specifies that rigid insulation shall be sealed at seams and penetrations as part of the air barrier system. The project is associated with Solicitation No. W912D25S0017 and is dated April 29, 2025, with design and drawing completed by C. Ganley and C. Newman from the New York District of the US Army Corps of Engineers.

View the file

Other files for this federal contract opportunity

Other files attached to WVA Fire Station Construction Acquisition, newest first.
File Type Posted
ET601 - TELECOMM RISER DIAGRAM.pdf PDF
01 45 00.15 10.pdf PDF
Solicitation Amendment W912DS25RA009_0009(final).pdf PDF
Solicitation Amendment W912DS25RA009_0008 (final).pdf PDF
Amendment W912DS25RA0090007.pdf PDF
Solicitation Amendment W912DS25RA009 0006.pdf PDF
01 50 00.pdf PDF
Solicitation Amendment W912DS25RA0090005.pdf PDF
FINAL_GeotechnicalReport_WatervlietArsenal_Rev1 8-7-23.pdf PDF
WVA Fire Station A-604 20250814.pdf PDF
25-08-11_I-601 and I-602.pdf PDF
09 51 00.pdf PDF
Solicitation Amendment W912DS25RA0090004 SF 30.pdf PDF
WVA Fire Station A-602 20250814.pdf PDF
FINAL_GeotechnicalReport_WatervlietArsenal_Rev1 8-7-23.pdf PDF
08 71 00.pdf PDF
MI703.pdf PDF
ET-601 - TELECOMM RISER DIAGRAM.pdf PDF
ES103 - ELECTRICAL - SITE PLAN - POWER -TELECOMMUNICATIONS.pdf PDF
12 24 13.pdf PDF
WVA Fire Station A-603 20250801.pdf PDF
WVA Fire Station A-511 20250730.pdf PDF
WVA Fire Station A-510 20250730.pdf PDF
WVA Fire Station A-310 20250730.pdf PDF
WVA Fire Station A-123 20250730.pdf PDF
AHJ Interpretation - FP Quals.pdf PDF
07 21 16.pdf PDF
07 21 13.pdf PDF
WVA Fire Station A-602 20250801.pdf PDF
WVA Fire Station A-507 20250730.pdf PDF
WVA Fire Station A-501 20250730.pdf PDF
Solicitation Amendment W912DS25RA009 0003.pdf PDF
06 41 16.00 10.pdf PDF
01 45 00.pdf PDF
WVA Fire Station A-503 20250730.pdf PDF
WVA Fire Station A-122 20250730.pdf PDF
WVA Fire Station JA Plymovent Vehicle Exhaust System_sOAS.pdf PDF
WVA Fire Station JA Simplex Fire Alarm System_sOAS.pdf PDF
Solicitation Amendment W912DS25RA009 0002.pdf PDF
Attendance List 21 July 2025.pdf PDF
Site Visit Photos.pdf PDF
W912DS25RA009 Amendment 0001.pdf PDF
CID PACKAGE.pdf PDF
Solicitation - W912DS25RA009(4).pdf PDF
WVA Fire Station - Drawings - RTA 20250624.pdf PDF
WVA-FIRESTATION_RTA_SPEC_07-11-2025.pdf PDF
Show all 46

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1' - 8"

EXTERIORINTERIOR

INTERIOR

1" / 1'-0"

FLUID APPLIED

AIR BARRIER

SPRAY FOAM

AIR BARRIER

RIGID INSULATION

CONTINUOUS FLUID

APPLIED AIR BARRIER

EXPANSION JOINT

RIGID INSULATION

INTERIOR EXTERIOR

INTERIOR

CONTINUOUS FLUID

APPLIED AIR BARRIER

FLUID APPLIED AIR BARRIER

SPRAY FOAM AIR BARRIER

STOREFRONT

WINDOW

SPRAY FOAM APPLIED

AIR BARRIER

CONTINUOUS FLUID

APPLIED AIR BARRIER

SEALANT AND

BACKER RODS

SEALANT AND

BACKER RODS

RIGID INSULATION

RIGID INSULATION

INTERIOR

0' - 11 1/2"

EXTERIORINTERIOR

SPRAY FOAM AIR BARRIER

FLUID APPLIED AIR BARRIER

RIGID INSULATION

RIGID INSULATION

LATEX PAINT

A

INTERIOR EXTERIOR

FLUID APPLIED AIR BARRIER

SPRAY FOAM AIR BARRIER

SEALANT AND BACKER RODS

STOREFRONT WINDOW

RIGID INSULATION

A.9

INTERIOR EXTERIOR

INTERIOR INTERIOR

CONTINUOUS FLUID

APPLIED AIR BARRIER

CONCRETE FLOOR SLAB

ALL PENETRATIONS TO

BE SEALED

2'0 1'6"

SCALE: 1 1/2" = 1'-0"

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

C

U s e rs

\e e n d c m g \D o c u m e n ts

\W V

A -F

S -D

M M

-A -M

D L c g a n le y .r v t

/3

/2

:3

:3

P

M

A-121

A

IR

B A

R R

IE

R

D E

T A

IL

S

W A

T E

R V

L

IE

T A

R S

E N

A L N

Y N

E W

Y O

R K

D

IS

T R

IC

T

F

E D

E R

A L P

L A

Z A

N E

W Y

O R

K N

Y

C .G

A N

L E

Y

C .G

A N

L E

Y

C .G

A N

L E

Y

C .N

E W

M A

N

A P

R

IL

W D

S

C

O M

P A

N Y

F

IR

E S

T A

T

IO

N

1 1/2" = 1'-0"

ROOF EAVE DETAIL AT HIGH END OF

ROOF ON CMU WALL AIR BARRIER

DETAIL

1 1/2" = 1'-0"

ROOF EAVE AT CLERESTORY WINDOW

DETAIL AIR BARRIER DETAIL

1 1/2" = 1'-0"

ROOF EAVE DETAIL AT APPARATUS

BAY STUD WALL AIR BARRIER DETAIL

1 1/2" = 1'-0"

ROOF EAVE DETAIL AT STOREFRONT

AIR BARRIER DETAIL

1 1/2" = 1'-0"

WALL AND ROOF INTERSECTION DETAIL

AT STEEL BEAM AT LOBBY AIR BARRIER

DETAIL

*RIGID INSULATION SHALL BE SEALED AT

SEAMS AND PENETRATIONS CONSIDERED

PART OF AIR BARRIER SYSTEM

Sheets
A-121 - AIR BARRIER DETAILS
A-122 - AIR BARRIER DETAILS
A-123 - AIR BARRIER DETAILS

File details come from the government source that posted it. Updated .