WVA Fire Station A-603 20250801.pdf

PDF 81 KB Posted

Attached to
WVA Fire Station Construction Acquisition Federal contract opportunity
Solicitation number
W912DS25RA009
Issued by
Department of the Army Corps of Engineers Engineering District New York

About this file

This document is a Door Schedule sheet (A-603) for a US Army Corps of Engineers project at the Watervliet Arsenal in New York, specifically for a Company Fire Station. The schedule details 128 total doors across multiple types (A through N), with specific dimensional and material specifications for each door. Most doors are either wood or hollow metal, with varying widths between 2'10" and 3'0" and heights of 6'8" to 7'0". The majority have a 1-hour fire rating, and hardware sets are specified using numeric codes (such as H05, H07, H11). The doors are categorized by interior and exterior types, with materials including wood, aluminum, glass, and hollow metal, and are intended for use in different building locations and functional requirements.

View the file

Other files for this federal contract opportunity

Other files attached to WVA Fire Station Construction Acquisition, newest first.
File Type Posted
Solicitation Amendment W912DS25RA009_0009(final).pdf PDF
01 45 00.15 10.pdf PDF
ET601 - TELECOMM RISER DIAGRAM.pdf PDF
Solicitation Amendment W912DS25RA009_0008 (final).pdf PDF
Amendment W912DS25RA0090007.pdf PDF
01 50 00.pdf PDF
Solicitation Amendment W912DS25RA009 0006.pdf PDF
Solicitation Amendment W912DS25RA0090005.pdf PDF
FINAL_GeotechnicalReport_WatervlietArsenal_Rev1 8-7-23.pdf PDF
MI703.pdf PDF
ET-601 - TELECOMM RISER DIAGRAM.pdf PDF
ES103 - ELECTRICAL - SITE PLAN - POWER -TELECOMMUNICATIONS.pdf PDF
12 24 13.pdf PDF
WVA Fire Station A-602 20250814.pdf PDF
FINAL_GeotechnicalReport_WatervlietArsenal_Rev1 8-7-23.pdf PDF
08 71 00.pdf PDF
WVA Fire Station A-604 20250814.pdf PDF
25-08-11_I-601 and I-602.pdf PDF
09 51 00.pdf PDF
Solicitation Amendment W912DS25RA0090004 SF 30.pdf PDF
WVA Fire Station A-503 20250730.pdf PDF
WVA Fire Station A-122 20250730.pdf PDF
06 41 16.00 10.pdf PDF
01 45 00.pdf PDF
WVA Fire Station A-121 20250730.pdf PDF
WVA Fire Station A-602 20250801.pdf PDF
WVA Fire Station A-507 20250730.pdf PDF
WVA Fire Station A-501 20250730.pdf PDF
Solicitation Amendment W912DS25RA009 0003.pdf PDF
WVA Fire Station A-511 20250730.pdf PDF
WVA Fire Station A-510 20250730.pdf PDF
WVA Fire Station A-310 20250730.pdf PDF
WVA Fire Station A-123 20250730.pdf PDF
AHJ Interpretation - FP Quals.pdf PDF
07 21 16.pdf PDF
07 21 13.pdf PDF
Solicitation Amendment W912DS25RA009 0002.pdf PDF
WVA Fire Station JA Simplex Fire Alarm System_sOAS.pdf PDF
WVA Fire Station JA Plymovent Vehicle Exhaust System_sOAS.pdf PDF
W912DS25RA009 Amendment 0001.pdf PDF
Site Visit Photos.pdf PDF
Attendance List 21 July 2025.pdf PDF
WVA-FIRESTATION_RTA_SPEC_07-11-2025.pdf PDF
WVA Fire Station - Drawings - RTA 20250624.pdf PDF
CID PACKAGE.pdf PDF
Solicitation - W912DS25RA009(4).pdf PDF
Show all 46

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TYPE AINTERIOR

HOLLOW

METAL

TYPE B

WOOD

TYPE C TYPE D TYPE F

WOOD

TYPE G

HOLLOW

METAL

TYPE H

3' - 0"

"2

"2

5" 6"

3' - 0"

6" 2' - 0" 6"

TYPE E

3' - 0"

6" 2' - 0" 6"

6' - 0"

WOOD

ALUM. WOOD

@ SLAB ON GRADE

TYPE J

EXTERIOR

TYPE K

HOLLOW

METAL

TYPE L TYPE M

HOLLOW

METAL

TYPE I TYPE N

STOREFRONT

GLASS

ALUMINUM

GLASS

ALUMINUM

0' - 2" 3' - 0" 0' - 2"

3' - 4"

0' - 2" 3' - 0" 0' - 2"

3' - 4"

0' - 2" 6' - 0" 0' - 2"

6' - 4"

2' - 10"

0' - 2"2' - 6"0' - 2"

@ SLAB ON GRADE

TYPE I

0' - 2" 5' - 8" 0' - 2"

6' - 0"

0' - 2" 5' - 0" 0' - 2"

5' - 4"

0' - 2" 2' - 6" 0' - 2"

2' - 10"

0' - 2" 2' - 8"

0' - 2"

3' - 0"

TYPE 2 TYPE 3 TYPE 4 TYPE 5 TYPE 6 TYPE 7 TYPE 8

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

C

U s e rs

\e e n d c m g \D o c u m e n ts

\W V

A -F

S -D

M M

-A -M

D L c g a n le y .r v t

/1

/2

:0

:2

P

M

A-603

D O

O R

S C

H E

D U

L E

W A

T E

R V

L

IE

T A

R S

E N

A L N

Y N

E W

Y O

R K

D

IS

T R

IC

T

F

E D

E R

A L P

L A

Z A

N E

W Y

O R

K N

Y

C .G

A N

L E

Y

C .G

A N

L E

Y

C .N

E W

M A

N

A P

R

IL

W D

S

C

O M

P A

N Y

F

IR

E S

T A

T

IO

N

DOOR SCHEDULE SHEET

DR. NO. TYPE

DOOR

FR STC

FRAME

HDW SET ATFP REQ. REMARKS

SIZE

MAT UNDER CUT TYPE MAT

DETAILS

WIDTH HEIGHT THK HEAD JAMB

209 B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H05

211 B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H05

212 A 3' - 0" 7' - 0" 0' - 2" HOLLOW METAL 1 HR 30 1 HM 5 6 H07

213 B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H05

214 A 3' - 0" 7' - 0" 0' - 2" HOLLOW METAL 1 HR 30 1 HM 5 6 H07

215 B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H05

216 A 3' - 0" 7' - 0" 0' - 2" HOLLOW METAL 1 HR 30 1 HM 8 9 H11

217 A 3' - 0" 7' - 0" 0' - 2" HOLLOW METAL 1 HR 30 1 HM 5 6 H11

218 A 3' - 0" 7' - 0" 0' - 2" HOLLOW METAL 1 HR 30 1 HM 5 6 H07

218A B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H07

220 B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H05

221 B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H05

222 B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H05

223 B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H05

224 B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H05

225 C 3' - 0" 6' - 8" 0' - 2" WOOD 1 HR 30 3 HM 5 6 H01

226 B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H05

227 B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H05

228 B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H15

228A B 2' - 10" 6' - 8" 0' - 2" WOOD 30 4 HM 5 6 H01

229 B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H05

230 B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H15

230A B 2' - 10" 6' - 8" 0' - 2" WOOD 30 4 HM 5 6 H01

231 B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H05

Grand total: 128

GENERAL NOTES

LEGEND

1. REFER TO FLOOR PLANS AND ELEVATIONS FOR LOCATIONS OF ALL DOORS.

2. REFER TO SPECIFICATIONS FOR ANCHORING REQUIREMENTS.

3. FIELD VERIFY ALL OPENINGS PRIOR TO DOOR FABRICATION.

4. SEE GLAZING SPEC FOR REQUIREMENTS AND EXACT THICKNESS

5. REFER TO THE SPECIFICATIONS FOR DOOR HARDWARE

6. ALL DOOR GLAZING SHALL BE 1/2" TEMPERED GLASS

7. REFER TO DRAWING A-501 FOR INTERIOR AND EXTERIOR DOOR DETAILS

8. SEE A-602 FOR DOOR AND FRAME TYPES

HM HOLLOW METAL

INSUL HM INSULATED HOLLOW METAL

EXT EXTERIOR

STL STEEL

THK THICKNESS

MAT MATERIAL

FIN FINISH

FR FIRE RATING

HDW HARDWARE

Sheets
A-602 - DOOR SCHEDULE
A-603 - DOOR SCHEDULE
A-604 - WINDOW SCHEDULE

File details come from the government source that posted it. Updated .