This document is a detailed Door Hardware specification (Section 08 71 00) for the WVA Fire Station project, dated August 14, 2025. The specification provides comprehensive requirements for door hardware components, including hinges, locks, exit devices, closers, thresholds, weatherstripping, and electrical hardware. It specifies precise technical standards from various organizations like ANSI/BHMA, NFPA, and ASTM, with a focus on Grade 1 commercial-grade hardware for durability and performance.

The document includes 17 distinct hardware sets (H01-H17) with specific configurations for different doors, ranging from single doors to paired doors with various functionalities. Key hardware requirements include stainless steel construction, fire-rated components, accessibility compliance, and integration with electronic security systems. The specification mandates specific finishes (primarily BHMA 630 satin stainless steel), detailed installation guidelines, and comprehensive submittal requirements including shop drawings, product data, hardware schedules, and key control documentation. The hardware sets incorporate elements like continuous hinges, exit devices, closers, electromagnetic locks, electric strikes, and weatherstripping, tailored to the specific needs of each door in the fire station.

View the file

Other files for this federal contract opportunity

Other files attached to WVA Fire Station Construction Acquisition, newest first.
File Type Posted
ET601 - TELECOMM RISER DIAGRAM.pdf PDF
01 45 00.15 10.pdf PDF
Solicitation Amendment W912DS25RA009_0009(final).pdf PDF
Solicitation Amendment W912DS25RA009_0008 (final).pdf PDF
Amendment W912DS25RA0090007.pdf PDF
Solicitation Amendment W912DS25RA009 0006.pdf PDF
01 50 00.pdf PDF
Solicitation Amendment W912DS25RA0090005.pdf PDF
FINAL_GeotechnicalReport_WatervlietArsenal_Rev1 8-7-23.pdf PDF
WVA Fire Station A-604 20250814.pdf PDF
25-08-11_I-601 and I-602.pdf PDF
09 51 00.pdf PDF
Solicitation Amendment W912DS25RA0090004 SF 30.pdf PDF
WVA Fire Station A-602 20250814.pdf PDF
FINAL_GeotechnicalReport_WatervlietArsenal_Rev1 8-7-23.pdf PDF
MI703.pdf PDF
ET-601 - TELECOMM RISER DIAGRAM.pdf PDF
ES103 - ELECTRICAL - SITE PLAN - POWER -TELECOMMUNICATIONS.pdf PDF
12 24 13.pdf PDF
06 41 16.00 10.pdf PDF
01 45 00.pdf PDF
WVA Fire Station A-121 20250730.pdf PDF
WVA Fire Station A-603 20250801.pdf PDF
WVA Fire Station A-511 20250730.pdf PDF
WVA Fire Station A-510 20250730.pdf PDF
WVA Fire Station A-310 20250730.pdf PDF
WVA Fire Station A-123 20250730.pdf PDF
AHJ Interpretation - FP Quals.pdf PDF
07 21 16.pdf PDF
07 21 13.pdf PDF
WVA Fire Station A-602 20250801.pdf PDF
WVA Fire Station A-507 20250730.pdf PDF
WVA Fire Station A-501 20250730.pdf PDF
Solicitation Amendment W912DS25RA009 0003.pdf PDF
WVA Fire Station A-503 20250730.pdf PDF
WVA Fire Station A-122 20250730.pdf PDF
WVA Fire Station JA Simplex Fire Alarm System_sOAS.pdf PDF
WVA Fire Station JA Plymovent Vehicle Exhaust System_sOAS.pdf PDF
Solicitation Amendment W912DS25RA009 0002.pdf PDF
Site Visit Photos.pdf PDF
Attendance List 21 July 2025.pdf PDF
W912DS25RA009 Amendment 0001.pdf PDF
WVA Fire Station - Drawings - RTA 20250624.pdf PDF
CID PACKAGE.pdf PDF
Solicitation - W912DS25RA009(4).pdf PDF
WVA-FIRESTATION_RTA_SPEC_07-11-2025.pdf PDF
Show all 46

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WVA Fire Station WVAFIRESTATION23 Amendment 004 August 14, 2025

SECTION 08 71 00

DOOR HARDWARE

02/16, CHG 4: 02/22

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM E283 (2019) Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen

ASTM F883 (2013; R 2022) Standard Performance Specification for Padlocks

BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)

ANSI/BHMA A156.1 (2021) Butts and Hinges

ANSI/BHMA A156.2 (2017) Bored and Preassembled Locks and Latches

ANSI/BHMA A156.3 (2020) Exit Devices

ANSI/BHMA A156.4 (2013) Door Controls - Closers

ANSI/BHMA A156.5 (2020) Cylinder and Input Devices for Locks

ANSI/BHMA A156.6 (2021) Architectural Door Trim

ANSI/BHMA A156.7 (2016) Template Hinge Dimensions

ANSI/BHMA A156.8 (2021) Door Controls - Overhead Stops and Holders

ANSI/BHMA A156.10 (2017) Power Operated Pedestrian Doors

ANSI/BHMA A156.13 (2017) Mortise Locks & Latches Series 1000

ANSI/BHMA A156.14 (2013) Sliding and Folding Door Hardware

ANSI/BHMA A156.15 (2021) Release Devices Closer Holder, Electromagnetic and Electromechanical

ANSI/BHMA A156.16 (2018) Auxiliary Hardware

ANSI/BHMA A156.18 (2020) Materials and Finishes

ANSI/BHMA A156.19 (2013) Power Assist & Low Energy Power

SECTION 08 71 00 Page 1

Operated Doors

ANSI/BHMA A156.21 (2019) Thresholds

ANSI/BHMA A156.22 (2021) Gasketing

ANSI/BHMA A156.23 (2010) Electromagnetic Locks

ANSI/BHMA A156.24 (2012) Delayed Egress Locking Systems

ANSI/BHMA A156.25 (2013) Electrified Locking Devices

ANSI/BHMA A156.26 (2012) Continuous Hinges

ANSI/BHMA A156.27 (2011) Power and Manual Operated Revolving Pedestrian Doors

ANSI/BHMA A156.29 (2012) Exit Locks, Exit Alarms, Alarms for Exit Devices

ANSI/BHMA A156.31 (2013) Electric Strikes and Frame Mounted Actuators

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

NFPA 70 (2020; TIA 22-1; ERTA 1 2022) National Electrical Code

NFPA 72 (2022) National Fire Alarm and Signaling Code

NFPA 80 (2022) Standard for Fire Doors and Other Opening Protectives

NFPA 101 (2021; TIA 21-1) Life Safety Code

NFPA 252 (2022) Standard Methods of Fire Tests of Door Assemblies

STEEL DOOR INSTITUTE (SDI/DOOR)

SDI/DOOR A250.8 (2017) Specifications for Standard Steel Doors and Frames

U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)

36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines

UNDERWRITERS LABORATORIES (UL)

UL 14C (2006; Reprint Oct 2021) UL Standard for Safety Swinging Hardware for Standard Tin-Clad Fire Doors Mounted Singly and in Pairs

UL Bld Mat Dir (updated continuously online) Building

SECTION 08 71 00 Page 2

Materials Directory

1.2 SUBMITTALS

Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are for information only. When used, a code following the "G" classification identifies the office that will review the submittal for the Government.

Submit the following in accordance with Section 01 33 00 SUBMITTAL

PROCEDURES:

SD-02 Shop Drawings

Manufacturer's Detail Drawings ; G,DO

Verification of Existing Conditions ; G

Hardware Schedule ; G

Keying System ; G

SD-03 Product Data

Hardware Items ; G,DO

SD-08 Manufacturer's Instructions

Installation

SD-10 Operation and Maintenance Data

Hardware Schedule Items, Data Package 1; G

SD-11 Closeout Submittals

Key Bitting

1.3 SHOP DRAWINGS

Submit manufacturer's detail drawings indicating all hardware assembly components and interface with adjacent construction. Indicate power components and wiring coordination for electrified hardware. Base shop drawings on verified field measurements and include verification of existing conditions .

1.4 PRODUCT DATA

Indicate fire-ratings at applicable components. Provide documentation of ABA/ADA accessibility compliance of applicable components, as required by 36 CFR 1191 Appendix D - Technical.

1.5 HARDWARE SCHEDULE

Provide Hardware Item List and Hardware Schedule containing the following information, and additional information as needed to identify the complete make up of each hardware set and its application to each opening:

SECTION 08 71 00 Page 3

1.5.1 Hardware Item List:

a. Hardware Type

b. Item Number

c. Quantity

d. Size(s)

e. Reference Publication / Type Number

f. Manufacturer's Name / Catalog Number

g. Key Control Symbols

h. UL Mark (If fire rated and listed)

i. BHMA Finish(es)

j. Remarks

1.5.2 Hardware Schedule

a. Hardware Set Number

b. Opening Number(s)

c. Opening Description (single/double leaf, hand, size, door/frame material)

d. Fire Rating

e. Sound Rating

f. Hardware Items

g. Quantity

h. Size

i. BHMA Finish

j. Remarks

In addition, submit hardware schedule data package 1 in accordance with Section 01 78 23 OPERATION AND MAINTENANCE DATA.

1.6 KEY BITTING CHART REQUIREMENTS

1.6.1 Requirements

Submit key bitting charts to the Contracting Officer prior to completion of the work. Include:

a. Complete listing of all keys (e.g. AA1 and AA2).

b. Complete listing of all key cuts (AA1-123456, AA2-123458).

SECTION 08 71 00 Page 4

c. Tabulation showing which key fits which door.

d. Copy of floor plan showing doors and door numbers.

e. Listing of 20 percent more key cuts than are presently required in each master system.

1.7 QUALITY ASSURANCE

1.7.1 Hardware Manufacturers and Modifications

Provide, as far as feasible, locks, hinges, and closers of one lock, hinge, or closer manufacturer's make. Modify hardware as necessary to provide features indicated or specified.

1.7.2 Key Shop Drawings Coordination Meeting

Prior to the submission of the key shop drawing, the Contracting Officer, Contractor, Door Hardware Subcontractor, using Activity and Base Locksmith must meet to discuss and coordinate key requirements for the facility.

1.8 DELIVERY, STORAGE, AND HANDLING

Deliver hardware in original individual containers, complete with necessary appurtenances including fasteners and instructions. Mark each individual container with item number as shown on hardware schedule.

Deliver permanent keys and removable cores to the Contracting Officer, either directly or by certified mail. Deliver construction master keys with the locks.

PART 2 PRODUCTS

2.1 TEMPLATE HARDWARE

Hardware applied to metal or to prefinished doors must be manufactured using a template. Provide templates to door and frame manufacturers in accordance with ANSI/BHMA A156.7 for template hinges. Coordinate hardware items to prevent interference with other hardware.

2.2 HARDWARE FOR FIRE DOORS AND EXIT DOORS

Provide all hardware necessary to meet the requirements of NFPA 72 for door alarms, NFPA 80 for fire doors, NFPA 101 for exit doors, NFPA 252 for fire tests of door assemblies, ABA/ADA accessibility requirements, and all other requirements indicated, even if such hardware is not specifically mentioned in paragraph HARDWARE SCHEDULE. Provide swinging hardware for tin-clad fire doors in accordance with UL 14C . Provide Underwriters Laboratories, Inc. labels for such hardware in accordance with UL Bld Mat Dir or equivalent labels in accordance with another testing laboratory approved in writing by the Contracting Officer.

2.3 HARDWARE ITEMS

Clearly and permanently mark with the manufacturer's name or trademark, hinges, pivots, locks, latches, exit devices, bolts and closers where the identifying mark is visible after the item is installed. For closers with covers, the name or trademark may be beneath the cover. Coordinate electrified door hardware components with corresponding components specified in Division 28 ELECTRONIC SECURITY SYSTEMS (ESS).

SECTION 08 71 00 Page 5

2.3.1 Hinges

Provide in accordance with ANSI/BHMA A156.1 . Provide hinges that are 4-1/2 by 4-1/2 inch unless otherwise indicated. Construct loose pin hinges for interior doors and reverse-bevel exterior doors so that pins are non-removable when door is closed. Other anti-friction bearing hinges may be provided in lieu of ball bearing hinges.

2.3.2 Continuous Hinges

Where continuous hinges are required, provide in accordance with

ANSI/BHMA A156.26 .

2.3.3 Locks and Latches

a. At exterior locations provide locksets of full stainless steel type 302 or 304 construction including fronts, strike, escutcheons, knobs, bolts and all interior working parts. Marine Grade I, fully non-ferrous.

b. In non-air-conditioned interior environments or humid interior environments, provide interior locksets on the same Marine Grade I, fully non-ferrous as exterior locksets.

2.3.3.1 Mortise Locks and Latches

Provide in accordance with ANSI/BHMA A156.13 , Series 1000, Operational Grade 1, Security Grade 2. Provide mortise locks with escutcheons not less than 7 by 2-1/4 inch with a bushing at least 1/4 inch long. Cut escutcheons to fit cylinders and provide trim items with straight, beveled, or smoothly rounded sides, corners, and edges. Provide knobs and roses of mortise locks with screwless shanks and no exposed screws.

2.3.3.2 Bored Locks and Latches

Provide in accordance with ANSI/BHMA A156.2 , Series 4000, Grade 1.

2.3.3.3 Residential Bored Locks and Latches

Provide in accordance with ANSI/BHMA A156.2 , Series 4000, Grade 2.

Install locks for exterior doors with threaded roses or concealed machine screws.

2.3.4 Exit Devices

Provide in accordance with ANSI/BHMA A156.3 , Grade 1. Provide adjustable strikes for rim type and vertical rod devices. Provide open back strikes for pairs of doors with mortise and vertical rod devices. Provide touch bars in lieu of conventional crossbars and arms. Provide escutcheons not less than 7 by 2-1/4 inch .

Use stainless steel or bronze base metal with plated finishes. Also include stainless steel fasteners and screws.

2.3.5 Exit Locks With Alarm

Provide in accordance with ANSI/BHMA A156.3 and ANSI/BHMA A156.29 , Type E0431 (with full width horizontal actuating bar) for single doors; Type

SECTION 08 71 00 Page 6

E0431 (with actuating bar) or E0471 (with actuating bar and top and bottom bolts, both leaves active) for pairs of doors, unless otherwise specified. Provide terminals for connection to remote indicating panel.

Provide outside control key. Provide door alarms integrated with the fire alarm system in accordance with NFPA 72 .

2.3.6 Cylinders and Cores

Provide cylinders and cores for new locks, including locks provided under other sections of this specification. Provide cylinders and cores with seven pin tumblers. Provide cylinders from the products of one manufacturer, and provide cores from the products of one manufacturer.

Rim cylinders, mortise cylinders, and knobs of bored locksets have interchangeable cores which are removable by special control keys. Stamp each interchangeable core with a key control symbol in a concealed place on the core.

Provide cylinders for new locks, including locks provided under other sections of this specification. Provide fully compatible cylinders of Grade 1 products from products of one manufacturer with interchangeable cores that are removable by a special control key. Factory set the cores with seven pin tumblers using the A4 system and F keyway. Submit a core code sheet with the cores. Provide master keyed cores in one system for this project. Provide construction interchangeable cores.

2.3.7 Push Button Mechanisms

Provide in accordance with ANSI/BHMA A156.5 , Grade 1.

2.3.8 Electrified Hardware

Comply with the requirements of NFPA 70 for wiring of electrified hardware.

2.3.8.1 Electric Strikes and Frame Mounted Actuators

Provide in accordance with ANSI/BHMA A156.31 , Grade 1. Provide electric strikes and actuators as required to meet operational requirements.

Provide electric strikes that release automatically during power failure. Provide a separate power supply for electric strikes, other locking devices and ancillary parts. Provide battery backup for continued operation during power failure. Provide strikes and actuators with a minimum opening force of 2300 pounds .

Provide facility interface devices that use direct current (dc) power to energize the solenoids. Provide electric strikes and actuators that incorporate end-of-line resistors to facilitate line supervision by the system. If not incorporated into the electric strike or local controller, provide metal oxide resistors (MOVs) to protect the controller from reverse current surges.

2.3.8.1.1 Solenoid

Provide actuating solenoid for strikes and actuators that are rated for continuous duty, cannot dissipate more than 12 Watts and must operate on 12 or 24 Volts dc. Inrush current cannot exceed 1 ampere and the holding current cannot be greater than 500 milliamperes. Actuating solenoid must move from fully secure to fully open positions in less than 500 milliseconds.

SECTION 08 71 00 Page 7

2.3.8.1.2 Signal Switches

Provide strikes and actuators with signal switches to indicate to the system when the bolt is not engaged or the strike mechanism is unlocked.

Signal switches must report a forced entry to the system.

2.3.8.1.3 Tamper Resistance

Provide strike guards that prevent tampering with the latch bolt of the locking hardware or the latch bolt keeper of the electric strike. Strike guards to bolt through the door using tamper resistant screws. Provide strike guards made of 1/8 inch thick brass and that are 11-1/14 inch high by 1-5/8 inch wide , with a minimum 5/32 inch wide offset.

2.3.8.1.4 Coordination

Provide electric strikes and actuators of a size, weight and profile compatible with each specified door frame. Field verify installation clearances prior to procurement.

2.3.8.1.5 Mounting Method

Provide electric strikes and actuators suitable for use with single and double doors, with mortise or rim type hardware specified, and for right or left hand mounting as specified. In double door installations, locate the lock in the active leaf and monitor the fixed leaf.

2.3.8.2 Electrified Mortise Locks

Provide in accordance with ANSI/BHMA A156.25 , Grade 1. Provide electrified mortise locks that release automatically during power failure. Provide facility interface devices that use dc power to energize solenoids. Provide solenoids, resisters, and signal switches in accordance with paragraph ELECTRIC STRIKES AND FRAME MOUNTED ACTUATORS.

2.3.8.2.1 Power Transfer Hinges

Provide power transfer hinges with each electrified lock that route power and monitoring signals from the lockset to the door frame. Coordinate power transfer hinges with door frames.

2.3.8.3 Card Readers and Keypad Access Control Hardware

Provide in accordance with ANSI/BHMA A156.5 and ANSI/BHMA A156.25 , Grade 1 components. Provide devices that are tamper alarmed, tamper and vandal resistant, solid state, and do not contain electronics which could compromise the access control subsystem should the subsystem be attacked.

Provide surface, semi-flush, pedestal, or weatherproof mountable devices as specified for each individual location. Each device to contain a visual display, either mounted on the face, or on an integral part of the device, to indicate access or exit request processing, request approval, and request denial. Provide proximity, insertion, and swipe through type card readers capable of reading magnetic stripe ,high coercivity magnetic stripe , proximity Keypad Smart Card type access control cards. Provide keypads that contain an integral 12-digit tactile keyboard with digits arranged in numerical order. Provide keypads that are integrated into the card reader. Coordinate access control hardware with corresponding devices and systems specified in Division 28 ELECTRONIC SECURITY SYSTEMS

(ESS).

SECTION 08 71 00 Page 8

2.3.8.4 Power Operated Pedestrian Door Hardware

Provide in accordance with ANSI/BHMA A156.10 , Grade 1.

2.3.8.5 Release Devices

In accordance with ANSI/BHMA A156.15 , Grade 1.

2.3.8.5.1 Closer Holders

Provide floor mounted closer holder devices connected by integral releasing to fire detecting devices.

2.3.8.5.2 Release Devices

Provide wall orfloor mounted free swinging release devices connected to fire detecting devices.

2.3.8.6 Power Assist and Low Energy Power Operated Doors

Provide in accordance with ANSI/BHMA A156.19 , Grade 1.

2.3.8.7 Electromagnetic Locks

Provide in accordance with ANSI/BHMA A156.23 , Grade 1. Provide electromagnetic locks that do not contain any moving parts and depend solely upon electromagnetism to secure a portal by generating at least 1200 pounds of holding force. The lock must interface with the local processors without external, internal or functional alteration of the local processor. The electromagnetic lock must incorporate an end of line resistor to facilitate line supervision by the system. Provide metal-oxide resistors (MOVs) to protect controllers from reverse current surges, if not incorporated into the electromagnetic lock or local controller.

2.3.8.7.1 Armature

Provide electromagnetic locks with internal circuitry to eliminate residual magnetism and inductive kickback. Provide atuating armature that operates on 12 or 24 Volts dc and cannot dissipate more than 12 Watts.

Holding current must be less than 500 milliamperes. Actuating armature must take less than 300 milliseconds to change the status of the lock from fully secure to fully open or fully open to fully secure.

2.3.8.7.2 Tamper Resistance

Provide lock mechanism encased in hardened guard barriers to deter forced entry.

2.3.8.7.3 Mounting Method

Provide electromagnetic lock suitable for use with single and double door with mortise or rim type hardware and compatible with right or left hand mounting.

2.3.8.8 Delayed Egress Locking System

Provide in accordance with ANSI/BHMA A156.24 , Grade 1.

SECTION 08 71 00 Page 9

2.3.8.9 Power and Manual Operated Revolving Pedestrian Doors

Provide in accordance with ANSI/BHMA A156.27 , Grade 1.

2.3.9 Keying System

Provide a great master keying system.

2.3.10 Lock Trim

Provide cast, forged, or heavy wrought construction and commercial plain design for lock trim.

2.3.10.1 Knobs and Roses

Provide in accordance with ANSI/BHMA A156.2 and ANSI/BHMA A156.13 for knobs, roses, and escutcheons. For unreinforced knobs, roses, and escutcheons, provide a 0.050 inch thickness. For reinforced knobs, roses, and escutcheons, provide an outer shell thickness of 0.035 inch and a combined total thickness of 0.070 inch , except at knob shanks. Provide knob shanks 0.060 inch thick.

2.3.10.2 Lever Handles

Provide lever handles where indicated in the Hardware Schedule. Provide in accordance with ANSI/BHMA A156.3 for mortise locks of lever handles for exit devices. Provide lever handle locks with a breakaway feature (such as a weakened spindle or a shear key) to prevent irreparable damage to the lock when force in excess of that specified in ANSI/BHMA A156.13 is applied to the lever handle. Provide lever handles return to within 1/2 inch of the door face.

2.3.11 Keys

Provide one file key, one duplicate key, and one working key for each key change and for each master keying system. Provide one additional working key for each lock of each keyed-alike group.Provide two additional keys for each sleeping room.Coordinate with with Contracting Officer and Watervliet DPW on arsenal keying system. Provide a quantity of key blanks equal to 20 percent of the total number of file keys. Stamp each key with appropriate key control symbol and "U.S. property - do not duplicate." Do not place room number on keys.

2.3.12 Door Bolts

Provide in accordance with ANSI/BHMA A156.16 . Provide dustproof strikes for bottom bolts, except at doors having metal thresholds. Provide automatic latching flush bolts in accordance with ANSI/BHMA A156.3 , Type 25.

2.3.13 Closers

Provide in accordance with ANSI/BHMA A156.4 , Series C02000, Grade 1, with PT 4C. Provide with brackets, arms, mounting devices, fasteners, full size covers, except at storefront mounting, and other features necessary for the particular application. Size closers in accordance with manufacturer's printed recommendations, or provide multi-size closers, SECTION 08 71 00 Page 10

Sizes 1 through 6, and list sizes in the Hardware Schedule. Provide manufacturer's 10 year warranty.

Use stainless steel inside bracketed or door mounted closers on exterior doors. Non-ferrous closers, such as aluminum or cast bronze, are permissible where door utilization is minimal. On interior doors use closers of 302 or 304 stainless steel or non-ferrous materials. On surface-mounted closers use or apply rust inhibiting finish on all ferrous parts. Also apply this finish on concealed closers.

2.3.13.1 Identification Marking

Engrave each closer with manufacturer's name or trademark, date of manufacture, and manufacturer's size designation in locations that will be visible after installation.

2.3.14 Overhead Holders

Provide in accordance with ANSI/BHMA A156.8 .

2.3.15 Door Protection Plates

Provide in accordance with ANSI/BHMA A156.6 .

2.3.15.1 Sizes of Kick Plates

2 inch less than door width for single doors; 1 inch less than door width for pairs of doors. Provide 10 inch kick plates for flush doors and 1 inch less than height of bottom rail for panel doors.

2.3.16 Door Stops and Silencers

Provide in accordance with ANSI/BHMA A156.16 . Silencers Type L03011.

Provide three silencers for each single door, two for each pair.

2.3.17 Padlocks

Provide in accordance with ASTM F883.

2.3.18 Thresholds

Provide in accordance with ANSI/BHMA A156.21 . Use J35100, with vinyl or silicone rubber insert in face of stop, for exterior doors opening out, unless specified otherwise.

2.3.19 Weatherstripping Gasketing

Provide in accordance with ANSI/BHMA A156.22 . Provide the type and function designation where specified in paragraph HARDWARE SCHEDULE.

Provide a set to include head and jamb seals, sweep strips, and, for pairs of doors, astragals. Air leakage of weatherstripped doors not to exceed

1.25 cubic feet per minute of air per square foot of door area when tested in accordance with ASTM E283. Provide weatherstripping with one of the following:

2.3.19.1 Extruded Aluminum Retainers

Extruded aluminum retainers not less than 0.050 inch wall thickness with vinyl, neoprene, silicone rubber, or polyurethane inserts. Provide clear

SECTION 08 71 00 Page 11

(natural) anodized aluminum.

2.3.19.2 Interlocking Type

Zinc or bronze not less than 0.018 inch thick.

2.3.19.3 Spring Tension Type

Spring bronze or stainless steel not less than 0.008 inch thick.

2.3.20 Lightproofing and Soundproofing Gasketing

Provide in accordance with ANSI/BHMA A156.22 . Provide adjustable doorstops at heads,jambs and automatic door bottoms in accordance with the hardware set, of extruded aluminum, clear (natural) anodized, surface applied, with vinyl fin seals between plunger and housing. Provide doorstops with solid neoprene tube, silicone rubber, or closed cell sponge gasket. Provide door bottoms with adjustable operating rod and silicone rubber or closed cell sponge neoprene gasket. Provide doorstops that are mitered at corners. Provide type and function designation where specified in paragraph HARDWARE SETS.

2.3.21 Rain Drips

Provide in accordance with ANSI/BHMA A156.22 . Provide extruded aluminum rain drips, not less than 0.08 inch thick, clear anodized finish.

Provide the manufacturer's full range of color choices to the Contracting Officer for color selection. Provide rain drips with a 4 inch overlap on each side of each exterior door that is not protected by an awning, roof, eave or other horizontal projection. Set drips in sealant and fasten with stainless steel screws.

2.3.21.1 Door Rain Drips

Approximately 1-1/2 inch high by 5/8 inch projection. Align bottom with bottom edge of door.

2.3.21.2 Overhead Rain Drips

Approximately 1-1/2 inch high by 2-1/2 inch projection. Align bottom with door frame rabbet.

2.3.22 Auxiliary Hardware (Other than locks)

Provide in accordance with ANSI/BHMA A156.16 , Grade 1.

2.3.23 Sliding and Folding Door Hardware

Provide in accordance with ANSI/BHMA A156.14 , Grade 1. Finishes to match other hardware specified herein.

2.3.24 Special Tools

Provide special tools, such as spanner and socket wrenches and dogging keys, as required to service and adjust hardware items.

2.4 FASTENERS

Provide fasteners of type, quality, size, and quantity appropriate to the

SECTION 08 71 00 Page 12 specific application. Fastener finish to match hardware. Provide stainless steel or nonferrous metal fasteners in locations exposed to weather. Verify metals in contact with one another are compatible and will avoid galvanic corrosion when exposed to weather.

2.5 FINISHES

Provide in accordance with ANSI/BHMA A156.18 . Provide hardware in BHMA 630 finish (satin stainless steel), unless specified otherwise. Provide items not manufactured in stainless steel in BHMA 626 finish (satin chromium plated) over brass or bronze, except finish for surface door closers, and except BHMA 652 finish (satin chromium plated) BHMA 600 finish (primed for painting) for steel hinges. Provide hinges for exterior doors in stainless steel with BHMA 630 finish or chromium plated brass or bronze with BHMA 626 finish. Furnish exit devices in BHMA 626 finish in lieu of BHMA 630 finish except where BHMA 630 is specified under paragraph HARDWARE SETS. Match exposed parts of concealed closers to lock and door trim. Match hardware finish for aluminum doors to the doors.

2.6 KEY CABINET AND CONTROL SYSTEM

Provide in accordance with ANSI/BHMA A156.5 , E8351 (150 hooks). Type required to yield a capacity (number of hooks) 50 percent greater than the number of key changes used for door locks. Verify key cabinet type with User and Watervliet Arsenal DPW.

PART 3 EXECUTION

3.1 INSTALLATION

Provide hardware in accordance with manufacturers' printed installation instructions. Fasten hardware to wood surfaces with full-threaded wood screws or sheet metal screws. Provide machine screws set in expansion shields for fastening hardware to solid concrete and masonry surfaces.

Provide toggle bolts where required for fastening to hollow core construction. Provide through bolts where necessary for satisfactory installation.

3.1.1 Weatherstripping Installation

Provide full contact, weathertight seals that allow operation of doors without binding the weatherstripping.

3.1.1.1 Stop Applied Weatherstripping

Fasten in place with color matched sheet metal screws not more than 9 inch on center after doors and frames have been finish painted.

3.1.1.2 Interlocking Type Weatherstripping

Provide interlocking, self adjusting type on heads and jambs and flexible hook type at sills. Nail weatherstripping to door 1 inch on center and to heads and jambs at 4 inch on center.

3.1.1.3 Spring Tension Type Weatherstripping

Provide spring tension type on heads and jambs. Provide bronze nails with bronze. Provide stainless steel nails with stainless steel. Space nails

SECTION 08 71 00 Page 13 not more than 1-1/2 inch on center.

3.1.2 Lightproofing and Soundproofing Installation

Provide as specified for stop applied weatherstripping.

3.1.3 Threshold Installation

Extend thresholds the full width of the opening and notch end for jamb stops. Set thresholds in a full bed of sealant and anchor to floor with cadmium-plated, countersunk, steel screws in expansion sleeves. For aluminum thresholds placed on top of concrete surfaces, coat the underside surfaces that are in contact with the concrete with fluid applied waterproofing as a separation measure prior to placement.

3.2 FIRE DOORS AND EXIT DOORS

Provide hardware in accordance with NFPA 72 for door alarms, NFPA 80 for fire doors, NFPA 101 for exit doors, and NFPA 252 for fire tests of door assemblies. .

3.3 HARDWARE LOCATIONS

Provide in accordance with SDI/DOOR A250.8 , unless indicated or specified otherwise.

a. Kick and Armor Plates: Push side of single-acting doors. Both sides of double-acting doors.

b. Mop Plates: Bottom flush with bottom of door.

3.4 KEY CABINET AND CONTROL SYSTEM

Locate where directed. Tag one set of file keys and one set of duplicate keys. Place other keys in appropriately marked envelopes, or tag each key. Provide complete instructions for setup and use of key control system. On tags and envelopes, indicate door and room numbers or master or grand master key.

3.5 FIELD QUALITY CONTROL

After installation, protect hardware from paint, stains, blemishes, and other damage until acceptance of work. Submit notice of testing 15 days before scheduled, so that testing can be witnessed by the Contracting Officer. Adjust hinges, locks, latches, bolts, holders, closers, and other items to operate properly. Demonstrate that permanent keys operate respective locks, and give keys to the Contracting Officer. Correct, repair, and finish, errors in cutting and fitting and damage to adjoining work.

3.6 HARDWARE SETS

SECTION 08 71 00 Page 14

H01

- 3 EA. HINGE(A5111) 630

- 1 EA. LOCKSET F05 X 630

- 1 EA. CLOSER C02061 X 689

- 1 EA. THRESHOLD J32330 X 719

- 1 EA. KICK PLATE (Stainless Steel) J102 X 630 - B4E

- 1 WALL TYPE BUMPER EA L02101 X 626

- 3 EA. DOOR SILENCER L03011

H02

- 6 EA. HINGE(A5111) 630

- 1 EA. LOCKSET F05 X 630

- 2 EA. CLOSER C02061 X 689

- 1 EA THRESHOLD J32330 X 719

- 2 EA KICK PLATE (Stainless Steel) J102 X 630 - B4E

- 2 WALL TYPE BUMPER EA L02101 X 626

- 6 EA DOOR SILENCER L03011

H03

- 2 EA CONT. HINGE (A81041B) 630

- 1 EA LOCKSET F07 X 630

- 1 EA DOOR DRIP R3Y976 X 689

- 1 EA WEATHER GASKET R0Y165 X 719

- 1 EA THRESHOLD J36193 (THERMAL BARRIER) X 719

- 2 EA KICK PLATE (Stainless Steel) J102 X 630 - B4E

- 1 EA EXIT DEVICE, TYPE 8 (PUSH PAD) FUNCTION 08 (LEVER) X 628

H04

- 2 EA CONT. HINGE (A81041B) 630

- 1 EA LOCKSET F07 X 630

- 1 EA Manual Flushbolts on inactive leaf

- 2 EA DOOR DRIP R3Y976 X 689

- 2 EA WEATHER GASKET R0Y165 X 719

- 1 EA THRESHOLD J36193 (THERMAL BARRIER) X 719

- 2 EA KICK PLATE (Stainless Steel) J102 X 630 - B4E

- 2 EA EXIT DEVICE, TYPE 8 (PUSH PAD) FUNCTION 08 (LEVER) X 628

H05

- 3 EA HINGE(A5111) 630

- 1 EA PULL PLATES / FLAT PLATE (8" x 16") J407 / J304 x 630, BTB

- 1 EA LOCKSET F20 X 630

- 1 EA THRESHOLD J32330 X 719

- 1 EA. CLOSER C02061 X 689

- 1 EA KICK PLATE (Stainless Steel) J102 X 630 - B4E

- 1 WALL TYPE BUMPER EA L02101 X 626

- 3 EA DOOR SILENCER L03011

H06

- 6 EA. HINGE(A5111) 630

- 2 EA. PULL PLATES / FLAT PLATE (8" x 16") J407 / J304 x 630, BTB

- 1 EA. LOCKSET F21 X 630

SECTION 08 71 00 Page 15

- 1 EA. THRESHOLD J32330 X 719

- 2 EA. CLOSER C02061 X 689

- 2 EA. KICK PLATE (Stainless Steel) J102 X 630 - B4E

- 2 WALL TYPE BUMPER EA L02101 X 626

- 6 EA. DOOR SILENCER L03011

H07

- 3 EA HINGE(A5111) (MSP) 630

- 1 EA LOCKSET F35 X 630

- 1 EA KICK PLATE (Stainless Steel) J102 X 630 - B4E

- 1 EA THRESHOLD J32330 X 719

- 1 EA DOOR HOLDER L01381 X 626

- 1 EA. CLOSER C02061 X 689

H08

- 6 EA HINGE(A5111) (MSP) 630

- 2 EA LOCKSET F35 X 630

- 2 EA KICK PLATE (Stainless Steel) J102 X 630 - B4E

- 1 EA THRESHOLD J32330 X 719

- 2 EA DOOR HOLDER L01381 X 626

H09

- 1 EA. GEAR HINGE EDGE MOUNT - A51041G X 630

- 1 EA EXIT DEVICE, TYPE 8 (PUSH PAD) FUNCTION 08 (LEVER) X 628

- 1 EA. CLOSER C02061 X 689

- 1 EA WEATHER GASKET R0Y165 X 719

- 1 EA DOOR SWEEP R0A535 X 689

- 1 EA THRESHOLD J36193 (THERMAL BARRIER) X 719

- 1 EA KICK PLATE (Stainless Steel) J102 X 630 - B4E

- 3 EA DOOR SILENCER L03011

- 1 EA ELECTROMAGNETIC SHEAR LOCK, MORTISED IN HEADER - E08571-2000-EC7

- 1 EA. RIM MOUNTED ELECTRIC STRIKE E09361

H10

- 2 EA. GEAR HINGE EDGE MOUNT - A51041G X 630

- 2 EA EXIT DEVICE, TYPE 8 (PUSH PAD) FUNCTION 08 (LEVER) X 628

- 2 EA. CLOSER C02061 X 689

- 2 EA WEATHER GASKET R0Y165 X 719

- 2 EA DOOR SWEEP R0A535 X 689

- 1 EA THRESHOLD J36193 (THERMAL BARRIER) X 719

- 2 EA KICK PLATE (Stainless Steel) J102 X 630 - B4E

- 6 EA DOOR SILENCER L03011

H11

- 1 EA. GEAR HINGE EDGE MOUNT - A51041G X 630

- 1 EA EXIT DEVICE, TYPE 8 (PUSH PAD) FUNCTION 08 (LEVER) X 628

- 1 EA. CLOSER C02061 X 689

- 1 EA WEATHER GASKET R0Y165 X 719

- 1 EA DOOR SWEEP R0A535 X 689

- 1 EA THRESHOLD J36193 (THERMAL BARRIER) X 719

- 1 EA KICK PLATE (Stainless Steel) J102 X 630 - B4E

- 3 EA DOOR SILENCER L03011

H12

SECTION 08 71 00 Page 16

- 1 EA. BOX TRACK D8921

- 2 EA. HANGAR WITH TOP/BOTTOM MOUNT PLATE D8131

- 1 EA DOOR PULL D8431

- 1 EA END GUIDE AND STOP D8471

H13

- 2 EA. HINGE(A5111) 630

- 1 EA. THRESHOLD J32330 X 719

- 2 EA. KICK PLATE (Stainless Steel) J102 X 630 - B4E

- 2 WALL TYPE BUMPER EA L02101 X 626

- 6 EA. DOOR SILENCER L03011

- 2 EA. ELECTROMAGNETIC SHEAR LOCK, MORTISED IN HEADER - E08571-2000-EC7

- 1 EA. RIM MOUNTED ELECTRIC STRIKE E09361

H14

- 1 EA. CONT. HINGE (A81041B) 630

- 1 EA. EXIT DEVICE, TYPE 3 FUNCTION 08 (LEVER) X 628

- 1 EA. CLOSER C02061 X 689

- 1 EA. WEATHER GASKET R0Y165 X 719

- 1 EA. DOOR SWEEP R0A535 X 689

- 1 EA. THRESHOLD J36193 (THERMAL BARRIER) X 719

- 1 EA. KICK PLATE (Stainless Steel) J102 X 630 - B4E

- 3 EA. DOOR SILENCER L03011

H15

- 3 EA HINGE(A5111) 630

- 1 EA PULL PLATES / FLAT PLATE (8" x 16") J407 / J304 x 630, BTB

- 1 EA LOCKSET F19 X 630

- 1 EA THRESHOLD J32330 X 719

- 1 EA. CLOSER C02061 X 689

- 1 EA KICK PLATE (Stainless Steel) J102 X 630 - B4E

- 1 WALL TYPE BUMPER EA L02101 X 626

- 3 EA DOOR SILENCER L03011

H16

- 3 EA HINGE(A5111) 630

- 1 EA PULL PLATES / FLAT PLATE (8" x 16") J407 / J304 x 630, BTB

- 1 EA LOCKSET F21 X 630

- 1 EA THRESHOLD J32330 X 719

- 1 EA. CLOSER C02061 X 689

- 1 EA KICK PLATE (Stainless Steel) J102 X 630 - B4E

- 1 WALL TYPE BUMPER EA L02101 X 626

- 3 EA DOOR SILENCER L03011

H17

- 2 EA. GEAR HINGE EDGE MOUNT - A51041G X 630

- 2 EA EXIT DEVICE, TYPE 8 (PUSH PAD) FUNCTION 08 (LEVER) X 628

- 2 EA. CLOSER C02061 X 689

- 2 EA WEATHER GASKET R0Y165 X 719

- 2 EA DOOR SWEEP R0A535 X 689

- 1 EA THRESHOLD J36193 (THERMAL BARRIER) X 719

- 2 EA KICK PLATE (Stainless Steel) J102 X 630 - B4E

- 6 EA DOOR SILENCER L03011

SECTION 08 71 00 Page 17

- 1 EA. RIM MOUNTED ELECTRIC STRIKE E09361

-- End of Section --

SECTION 08 71 00 Page 18

08 71 00 - DOOR HARDWARE
PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 SHOP DRAWINGS
1.4 PRODUCT DATA
1.5 HARDWARE SCHEDULE
1.5.1 Hardware Item List:
1.5.2 Hardware Schedule
1.6 KEY BITTING CHART REQUIREMENTS
1.6.1 Requirements
1.7 QUALITY ASSURANCE
1.7.1 Hardware Manufacturers and Modifications
1.7.2 Key Shop Drawings Coordination Meeting

1.8 DELIVERY, STORAGE, AND HANDLING

PART 2 PRODUCTS
2.1 TEMPLATE HARDWARE
2.2 HARDWARE FOR FIRE DOORS AND EXIT DOORS
2.3 HARDWARE ITEMS
2.3.1 Hinges
2.3.2 Continuous Hinges
2.3.3 Locks and Latches
2.3.3.1 Mortise Locks and Latches
2.3.3.2 Bored Locks and Latches
2.3.3.3 Residential Bored Locks and Latches
2.3.4 Exit Devices
2.3.5 Exit Locks With Alarm
2.3.6 Cylinders and Cores
2.3.7 Push Button Mechanisms
2.3.8 Electrified Hardware
2.3.8.1 Electric Strikes and Frame Mounted Actuators
2.3.8.1.1 Solenoid
2.3.8.1.2 Signal Switches
2.3.8.1.3 Tamper Resistance
2.3.8.1.4 Coordination
2.3.8.1.5 Mounting Method
2.3.8.2 Electrified Mortise Locks
2.3.8.2.1 Power Transfer Hinges
2.3.8.3 Card Readers and Keypad Access Control Hardware
2.3.8.4 Power Operated Pedestrian Door Hardware
2.3.8.5 Release Devices
2.3.8.5.1 Closer Holders
2.3.8.5.2 Release Devices
2.3.8.6 Power Assist and Low Energy Power Operated Doors
2.3.8.7 Electromagnetic Locks
2.3.8.7.1 Armature
2.3.8.7.2 Tamper Resistance
2.3.8.7.3 Mounting Method
2.3.8.8 Delayed Egress Locking System
2.3.8.9 Power and Manual Operated Revolving Pedestrian Doors
2.3.9 Keying System
2.3.10 Lock Trim
2.3.10.1 Knobs and Roses
2.3.10.2 Lever Handles
2.3.11 Keys
2.3.12 Door Bolts
2.3.13 Closers
2.3.13.1 Identification Marking
2.3.14 Overhead Holders
2.3.15 Door Protection Plates
2.3.15.1 Sizes of Kick Plates
2.3.16 Door Stops and Silencers
2.3.17 Padlocks
2.3.18 Thresholds
2.3.19 Weatherstripping Gasketing
2.3.19.1 Extruded Aluminum Retainers
2.3.19.2 Interlocking Type
2.3.19.3 Spring Tension Type
2.3.20 Lightproofing and Soundproofing Gasketing
2.3.21 Rain Drips
2.3.21.1 Door Rain Drips
2.3.21.2 Overhead Rain Drips
2.3.22 Auxiliary Hardware Other than locks
2.3.23 Sliding and Folding Door Hardware
2.3.24 Special Tools
2.4 FASTENERS
2.5 FINISHES
2.6 KEY CABINET AND CONTROL SYSTEM
PART 3 EXECUTION
3.1 INSTALLATION
3.1.1 Weatherstripping Installation
3.1.1.1 Stop Applied Weatherstripping
3.1.1.2 Interlocking Type Weatherstripping
3.1.1.3 Spring Tension Type Weatherstripping
3.1.2 Lightproofing and Soundproofing Installation
3.1.3 Threshold Installation
3.2 FIRE DOORS AND EXIT DOORS
3.3 HARDWARE LOCATIONS
3.4 KEY CABINET AND CONTROL SYSTEM
3.5 FIELD QUALITY CONTROL
3.6 HARDWARE SETS