WVA Fire Station A-602 20250814.pdf

PDF 80 KB Posted

Attached to
WVA Fire Station Construction Acquisition Federal contract opportunity
Solicitation number
W912DS25RA009
Issued by
Department of the Army Corps of Engineers Engineering District New York

About this file

This document is a Door Schedule sheet for the US Army Corps of Engineers project at Watervliet Arsenal in New York. The schedule details comprehensive specifications for numerous doors across the facility, including door numbers, types, sizes, materials, fire ratings, and hardware requirements. The project involves a 3 Company Fire Station, with the solicitation number W912D25S0017, issued on April 29, 2025. The door types range from four-fold doors and exterior aluminum/glass doors to hollow metal and wood doors, with varying dimensions typically between 2'10" to 14'0" in width and 6'8" to 7'0" in height. The schedule includes specific details for each door, such as material (steel, aluminum, wood), fire rating, hardware set, and additional remarks like installation recommendations or special considerations.

View the file

Other files for this federal contract opportunity

Other files attached to WVA Fire Station Construction Acquisition, newest first.
File Type Posted
01 45 00.15 10.pdf PDF
ET601 - TELECOMM RISER DIAGRAM.pdf PDF
Solicitation Amendment W912DS25RA009_0009(final).pdf PDF
Solicitation Amendment W912DS25RA009_0008 (final).pdf PDF
Amendment W912DS25RA0090007.pdf PDF
01 50 00.pdf PDF
Solicitation Amendment W912DS25RA009 0006.pdf PDF
Solicitation Amendment W912DS25RA0090005.pdf PDF
FINAL_GeotechnicalReport_WatervlietArsenal_Rev1 8-7-23.pdf PDF
FINAL_GeotechnicalReport_WatervlietArsenal_Rev1 8-7-23.pdf PDF
08 71 00.pdf PDF
WVA Fire Station A-604 20250814.pdf PDF
25-08-11_I-601 and I-602.pdf PDF
09 51 00.pdf PDF
Solicitation Amendment W912DS25RA0090004 SF 30.pdf PDF
MI703.pdf PDF
ET-601 - TELECOMM RISER DIAGRAM.pdf PDF
ES103 - ELECTRICAL - SITE PLAN - POWER -TELECOMMUNICATIONS.pdf PDF
12 24 13.pdf PDF
WVA Fire Station A-602 20250801.pdf PDF
WVA Fire Station A-507 20250730.pdf PDF
WVA Fire Station A-501 20250730.pdf PDF
Solicitation Amendment W912DS25RA009 0003.pdf PDF
06 41 16.00 10.pdf PDF
01 45 00.pdf PDF
WVA Fire Station A-121 20250730.pdf PDF
WVA Fire Station A-603 20250801.pdf PDF
WVA Fire Station A-511 20250730.pdf PDF
WVA Fire Station A-510 20250730.pdf PDF
WVA Fire Station A-310 20250730.pdf PDF
WVA Fire Station A-123 20250730.pdf PDF
AHJ Interpretation - FP Quals.pdf PDF
07 21 16.pdf PDF
07 21 13.pdf PDF
WVA Fire Station A-503 20250730.pdf PDF
WVA Fire Station A-122 20250730.pdf PDF
WVA Fire Station JA Simplex Fire Alarm System_sOAS.pdf PDF
WVA Fire Station JA Plymovent Vehicle Exhaust System_sOAS.pdf PDF
Solicitation Amendment W912DS25RA009 0002.pdf PDF
Site Visit Photos.pdf PDF
Attendance List 21 July 2025.pdf PDF
W912DS25RA009 Amendment 0001.pdf PDF
CID PACKAGE.pdf PDF
Solicitation - W912DS25RA009(4).pdf PDF
WVA Fire Station - Drawings - RTA 20250624.pdf PDF
WVA-FIRESTATION_RTA_SPEC_07-11-2025.pdf PDF
Show all 46

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

F ile

P a th

P lo t D a te

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

C

U s e rs

\e e n d c m g \D o c u m e n ts

\W V

A -F

S -D

M M

-A -M

D L c g a n le y .r v t

/1

/2

:5

:4

A

M

A-602

D O

O R

S C

H E

D U

L E

W A

T E

R V

L

IE

T A

R S

E N

A L N

Y N

E W

Y O

R K

D

IS

T R

IC

T

F

E D

E R

A L P

L A

Z A

N E

W Y

O R

K N

Y

C .G

A N

L E

Y

C .G

A N

L E

Y

C .N

E W

M A

N

A P

R

IL

W D

S

C

O M

P A

N Y

F

IR

E S

T A

T

IO

N

DOOR SCHEDULE SHEET

DR. NO. TYPE

DOOR

FR STC

FRAME

HDW SET ATFP REQ. REMARKS

SIZE

MAT UNDER CUT TYPE MAT

DETAILS

WIDTH HEIGHT THK HEAD JAMB

001A I 14' - 0" 14' - 0" 0' - 2" 2 4 FOUR FOLD DOOR

001B I 14' - 0" 14' - 0" 0' - 2" 2 4 FOUR FOLD DOOR

001C I 14' - 0" 14' - 0" 0' - 2" 2 4 FOUR FOLD DOOR

001D I 14' - 0" 14' - 0" 0' - 2" 2 4 FOUR FOLD DOOR

001E J 3' - 0" 7' - 0" 0' - 2" ALUMINUM/GLASS 1 STL 1 2 H09 X EXTERIOR DOOR

001EA D 3' - 0" 7' - 0" 0' - 2" ALUMINUM/GLASS 30 1 STL 5 6 H11 X

001EAA J 3' - 0" 7' - 0" 0' - 2" ALUMINUM/GLASS 1 STL 3 4 H09 X EXTERIOR DOOR

001F J 3' - 0" 7' - 0" 0' - 2" ALUMINUM/GLASS 1 STL 1 2 H09 X EXTERIOR DOOR

001G I 14' - 0" 14' - 0" 0' - 2" 2 4 FOUR FOLD DOOR

001H I 14' - 0" 14' - 0" 0' - 2" 2 4 FOUR FOLD DOOR

001I I 14' - 0" 14' - 0" 0' - 2" 2 4 FOUR FOLD DOOR

001J I 14' - 0" 14' - 0" 0' - 2" 2 4 FOUR FOLD DOOR

001K J 3' - 0" 7' - 0" 0' - 2" ALUMINUM/GLASS 1 STL 1 2 H09 X EXTERIOR DOOR

001N N 6' - 5" 7' - 0 1/2" STOREFRONT ALUM H11 X FRAME DETAILS AND MATERIAL PER SPECS / DOOR MANUFACTURERS

RECOMMENDATIONS

001NA N 6' - 5 1/2" 7' - 0 1/2" STOREFRONT ALUM H17 X FRAME DETAILS AND MATERIAL PER SPECS / DOOR MANUFACTURERS

RECOMMENDATIONS

002A A 3' - 0" 7' - 0" 0' - 2" HOLLOW METAL 1 HR 30 1 HM 8 9 H07

002B A 3' - 0" 7' - 0" 0' - 2" HOLLOW METAL 30 1 HM 5 6 H01

002E D 3' - 0" 7' - 0" 0' - 2" ALUMINUM/GLASS 30 1 HM 5 6 H11

002EA J 3' - 0" 7' - 0" 0' - 2" ALUMINUM/GLASS 1 STL 3 4 H09 X EXTERIOR DOOR

002N G 6' - 0" 7' - 0" 0' - 2" HOLLOW METAL 30 2 HM 5 6 H13

003A A 3' - 0" 7' - 0" 0' - 2" HOLLOW METAL 1 HR 30 1 HM 8 9 H11

003B B 2' - 10" 6' - 8" 0' - 2" WOOD 8 HM 5 6 H11

003E J 3' - 0" 7' - 0" 0' - 2" ALUMINUM/GLASS 30 1 HM 5 6 H11

004 A 3' - 0" 6' - 8" 0' - 2" HOLLOW METAL 30 3 HM 8 9 H03

004E J 3' - 0" 7' - 0" 0' - 2" ALUMINUM/GLASS 1 STL 3 4 H09 X EXTERIOR DOOR

005 G 6' - 0" 7' - 0" 0' - 2" HOLLOW METAL 30 2 HM 8 9 H04

005A G 6' - 0" 7' - 0" 0' - 2" HOLLOW METAL 30 2 HM 5 6 H08

005B M 6' - 0" 7' - 0" 0' - 2" HOLLOW METAL 2 STL 3 4 H04 X EXTERIOR DOOR

008A A 3' - 0" 6' - 8" 0' - 2" HOLLOW METAL 3 HM 8 9 H07

008B G 6' - 0" 7' - 0" 0' - 2" HOLLOW METAL 2 HM 8 9 H08

008C A 3' - 0" 6' - 8" 0' - 2" HOLLOW METAL 3 HM 8 9 H07

008D J 3' - 0" 7' - 0" 0' - 2" ALUMINUM/GLASS 1 STL 1 2 H09 X EXTERIOR DOOR

101 B 2' - 10" 6' - 8" 0' - 2" WOOD 30 4 HM 5 6 H01

102 B 2' - 10" 6' - 8" 0' - 2" WOOD 30 4 HM 5 6 H16

103 C 3' - 0" 6' - 8" 0' - 2" HOLLOW METAL 30 3 HM 5 6 H16

103A B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H05

103B B 2' - 10" 6' - 8" 0' - 2" WOOD 30 4 HM 5 6 H15

104 F 5' - 8" 6' - 8" 0' - 2" WOOD 1 HR 30 5 HM 8 9 H06

105 C 3' - 0" 6' - 8" 0' - 2" HOLLOW METAL 30 3 HM 5 6 H16

105A B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H05

105B B 2' - 10" 6' - 8" 0' - 2" WOOD 30 4 HM 5 6 H15

106 C 3' - 0" 6' - 8" 0' - 2" HOLLOW METAL 30 3 HM 8 9 H16

108 C 3' - 0" 6' - 8" 0' - 2" HOLLOW METAL 30 3 HM 8 9 H16

109 C 3' - 0" 6' - 8" 0' - 2" HOLLOW METAL 1 HR 30 3 HM 8 9 H11

109A K 3' - 0" 7' - 0" 0' - 2" HOLLOW METAL 1 STL 3 4 H14 X EXTERIOR DOOR

110 B 2' - 10" 6' - 8" 0' - 2" WOOD 8 HM 5 6 H01

110A B 2' - 10" 6' - 8" 0' - 2" WOOD 30 8 HM 5 6 H07

110B B 2' - 10" 6' - 8" 0' - 2" WOOD 30 4 HM 5 6 H15

111A C 3' - 0" 6' - 8" 0' - 2" HOLLOW METAL 1 HR 30 3 HM 5 6 H01

111B B 2' - 10" 6' - 8" 0' - 2" WOOD 30 4 HM 5 6 H01

112 B 2' - 10" 6' - 8" 0' - 2" WOOD 30 8 HM 5 6 H15

113A C 3' - 0" 6' - 8" 0' - 2" HOLLOW METAL 1 HR 30 3 HM 5 6 H01

113B B 2' - 10" 6' - 8" 0' - 2" WOOD 30 4 HM 5 6 H07

113C B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H01

113D F 5' - 8" 6' - 8" 0' - 2" WOOD 1 HR 30 5 HM 5 6 H02

113E H 30 ACCORDIAN DOOR PER MANUFACTUERER RECOMMENDATIONS

114 B 2' - 10" 6' - 8" 0' - 2" WOOD 30 8 HM 5 6 H15

115A A 3' - 0" 6' - 8" 0' - 2" HOLLOW METAL 1 HR 30 HM 5 6 H11

115B A 3' - 0" 6' - 8" 0' - 2" WOOD 1 HR 30 3 HM 8 9 H11

115C G 5' - 0" 6' - 8" 0' - 2" HOLLOW METAL 1 HR 30 6 HM 8 9 H10

115D A 3' - 0" 7' - 0" 0' - 2" HOLLOW METAL 1 HR 30 1 HM 5 6 H07

116 B 2' - 10" 6' - 8" 0' - 2" WOOD 30 4 HM 5 6 H15

116A B 2' - 10" 6' - 8" 0' - 2" WOOD 30 8 HM 5 6 H05

117 B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H16

117A B 2' - 10" 6' - 8" 0' - 2" WOOD 30 8 HM 5 6 H05

117BA B 2' - 10" 6' - 8" 0' - 2" WOOD 30 8 HM 5 6 H15

117BB B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H15

118 A 3' - 0" 7' - 0" 0' - 2" HOLLOW METAL 1 HR 30 1 HM 5 6 H01

118A A 2' - 6" 6' - 8" 0' - 2" HOLLOW METAL 3/4" 30 4 HM 5 6 H15

118B B 2' - 10" 6' - 8" 0' - 2" WOOD 30 8 HM 5 6 H15

118C A 2' - 6" 6' - 8" 0' - 2" HOLLOW METAL 3/4" 30 4 HM 5 6 H15

118D A 2' - 6" 6' - 8" 0' - 2" HOLLOW METAL 3/4" 30 4 HM 5 6 H15

119A F 5' - 8" 6' - 8" 0' - 2" WOOD 1 HR 30 5 HM 5 6 H02

119B A 3' - 0" 6' - 8" 0' - 2" HOLLOW METAL 30 3 HM 5 6 H07

119C C 3' - 0" 6' - 8" 0' - 2" HOLLOW METAL 1 HR 30 3 HM 8 9 H01

119D C 3' - 0" 6' - 8" 0' - 2" HOLLOW METAL 30 3 HM 5 6 H15

119E B 2' - 10" 6' - 8" 0' - 2" WOOD 8 HM 5 6 H15

119F B 2' - 10" 6' - 8" 0' - 2" WOOD 30 4 HM 5 6 H07

120A G 5' - 0" 6' - 8" 0' - 2" HOLLOW METAL 1 HR 30 5 HM 8 9 H10

120B F 5' - 8" 6' - 8" 0' - 2" WOOD 1 HR 30 5 HM 5 6 H10

121 B 2' - 10" 6' - 8" 0' - 2" WOOD 30 8 HM 5 6 H15

122 B 3' - 0" 6' - 8" 0' - 2" WOOD 30 3 HM 5 6 H07

123 B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 8 9 H07

124A C 3' - 0" 6' - 8" 0' - 2" HOLLOW METAL 30 3 HM 5 6 H01

124AA E 2' - 8" 7' - 0" 0' - 1 1/2" WOOD 30 8 HM H12 POCKET DOOR, INSTALL PER MANUFACTURERS RECOMMENDATIONS

124AB E 2' - 8" 7' - 0" 0' - 1 1/2" WOOD 30 8 HM H12 POCKET DOOR, INSTALL PER MANUFACTURERS RECOMMENDATIONS

124B C 3' - 0" 6' - 8" 0' - 2" HOLLOW METAL 30 3 HM 5 6 H01

124CA J 3' - 0" 7' - 0" 0' - 2" ALUMINUM/GLASS 30 1 HM 5 6 H11

124CB J 3' - 0" 7' - 0" 0' - 2" ALUMINUM/GLASS 1 STL 3 4 H09 X EXTERIOR DOOR

125 M 6' - 0" 7' - 0" 0' - 2" HOLLOW METAL 2 STL 3 4 H04 X EXTERIOR DOOR

126 A 2' - 8" 7' - 0" 0' - 2" HOLLOW METAL 30 7 HM 5 6 H07

127 K 3' - 0" 7' - 0" 0' - 2" HOLLOW METAL 1 STL 3 4 H14 X EXTERIOR DOOR

127A A 3' - 0" 6' - 8" 0' - 2" HOLLOW METAL 1 HR 30 3 HM 5 6 H11

151 M 6' - 0" 7' - 0" 0' - 2" HOLLOW METAL 2 STL 3 4 H04 X EXTERIOR DOOR

201 B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H05

202 B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H07

203 B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H05

204A B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H07

204B A 3' - 0" 7' - 0" 0' - 2" HOLLOW METAL 1 HR 30 1 HM 5 6 H07

205 B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H05

206 G 5' - 0" 6' - 8" 0' - 2" HOLLOW METAL 1 HR 30 6 HM 5 6 H10

207 B 2' - 10" 6' - 8" 0' - 2" WOOD 1 HR 30 4 HM 5 6 H05

208A F 5' - 0" 6' - 8" 0' - 2" WOOD 1 HR 30 6 HM 5 6 H02

208B C 3' - 0" 6' - 8" 0' - 2" HOLLOW METAL 1 HR 30 3 HM 5 6 H01

GENERAL NOTES

LEGEND

1. REFER TO FLOOR PLANS AND ELEVATIONS FOR LOCATIONS OF ALL DOORS.

2. REFER TO SPECIFICATIONS FOR ANCHORING REQUIREMENTS.

3. FIELD VERIFY ALL OPENINGS PRIOR TO DOOR FABRICATION.

4. SEE GLAZING SPEC FOR REQUIREMENTS AND EXACT THICKNESS

5. REFER TO THE SPECIFICATIONS FOR DOOR HARDWARE

6. ALL DOOR GLAZING SHALL BE 1/2" TEMPERED GLASS

7. REFER TO DRAWING A-501 FOR DOOR DETAILS

8. REFER TO DRAWING A-503 FOR FOUR FOLD DOOR DETAILS

9. HEAD, JAMB AND SILL DETAILS FOR STOREFRONT DOORS TO BE SUBMITTED BY

MANUFACTURER FOR APPROVAL BY DESIGN OFFICE

10. SEE INTERIORS FOR FINISH THRESHOLD / TRANSIT DETAILS COORDINATE WITH

FINISH PLAN

HM HOLLOW METAL

INSUL HM INSULATED HOLLOW METAL

EXT EXTERIOR

STL STEEL

THK THICKNESS

MAT MATERIAL

FIN FINISH

FR FIRE RATING

HDW HARDWARE

Sheets