12 24 13.pdf
PDF 33 KB Posted
- Attached to
- WVA Fire Station Construction Acquisition Federal contract opportunity
- Solicitation number
- W912DS25RA009
About this file
This document is a technical specification (Section 12 24 13) for Roller Window Shades for a WVA Fire Station project, dated August 13, 2025. The specification provides detailed requirements for window shade installation, including comprehensive guidelines for both manually operated single and dual roller shades with specific performance standards. Key technical requirements include using corrosion-resistant steel or extruded aluminum rollers, light-blocking or light-filtering fabrics, and room-darkening shade options with precise specifications for light traps, operating mechanisms, and installation accessories.
The specification mandates strict quality assurance requirements, including installer qualifications with a minimum of ten years of experience, flammability testing per NFPA 701, electrical requirements per UL 325, and anti-microbial standards with 'No Growth' results per ASTM G21. Additional requirements include a 10-year manufacturer's warranty, recycled content for fiber components, and detailed installation instructions emphasizing precise mounting, leveling, and clean-up procedures. Submittals must include detailed drawings, location schedules, product data, samples, test reports, and certificates to ensure compliance with the comprehensive technical standards outlined in the document.
View the file
Other files for this federal contract opportunity
Show all 46
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WVA Fire Station WVAFIRESTATION23 Amendment 004 August 13, 2025
SECTION 12 24 13
ROLLER WINDOW SHADES
08/20
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by basic designation only.
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)
ANSI/WCMA A100.1 (2018) American National Standard for Safety of Window Covering Products
ASTM INTERNATIONAL (ASTM)
ASTM G21 (2015; R 2021; E 2021) Standard Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 701 (2023; ERTA 1 2023) Standard Methods of Fire Tests for Flame Propagation of Textiles and Films
UNDERWRITERS LABORATORIES (UL)
UL 325 (2017; Reprint Feb 2020) UL Standard for Safety Door, Drapery, Gate, Louver, and Window Operators and Systems
1.2 SUBMITTALS
Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are for information only. When used, a code following the "G" classification identifies the office that will review the submittal for the Government.
SD-02 Shop Drawings
Detailed Drawings ; G
Location Schedule ; G
SD-03 Product Data
Window Shades ; G
SD-04 Samples
Window Shades ; G
SD-06 Test Reports
SECTION 12 24 13 Page 1
Flammability Requirements ; G
SD-07 Certificates
Qualifications
SD-10 Operation and Maintenance Data
Window Shades , Data Package 1; G
SD-11 Closeout Submittals
1.3 QUALITY ASSURANCE
1.3.1 Qualifications
1.3.1.1 Installer's Qualifications
Installer trained and certified by the manufacturer with a minimum of ten years of experience in installing products comparable to those specified in this section.
1.3.2 Flammability Requirements
Passes in accordance with NFPA 701 small and large-scale vertical burn.
Materials tested are identical to products proposed for use.
1.3.3 Electrical Requirements
NFPA Article 100 listed and labeled in accordance with UL 325 or other testing agency acceptable to authorities having jurisdiction, marked for intended use, and tested as a system. Individual testing of components is not acceptable in lieu of system testing.
1.3.4 Anti-Microbial Requirements
'No Growth' per ASTM G21 results for fungi ATCC9642, ATCC 9644, ATCC9645.
1.4 DELIVERY, STORAGE, AND HANDLING
Deliver components to the jobsite in the manufacturer's original packaging with the brand or company name, item identification, and project reference clearly marked. Store components in a dry location that is adequately ventilated and free from dust, water, or other contaminants and has easy access for inspection and handling. Store materials flat in a clean dry area with temperature maintained above 50 degrees F . Do not open containers until needed for installation unless verification inspection is required. Handle and store shades in accordance with manufacturer's recommendations.
1.5 WARRANTY
Provide manufacturer's warranty to repair or replace defective materials and workmanship for a period of 10 years from date of final acceptance of the work.
SECTION 12 24 13 Page 2
PART 2 PRODUCTS
2.1 WINDOW SHADES
Submit drawings showing plans, elevations, sections, product details, installation details, operational clearances, wiring diagrams and relationship to work. Submit a location schedule showing location, size and quantity of shades. Include the use of same room designations as indicated on the drawings.
Provide product data composed of catalog cuts, brochures, and operating and maintenance instructions on each product to be used. Include styles, profiles and features.
Furnish samples of each type and color of roller shade fabric and roller shade channel. Provide shade material minimum 6 by 6 inches in size.
Mark face of material to indicate interior faces.
Mock up: Install shade in area designated by Contracting Officer. Do not proceed with remaining work until the Contracting Officer approves workmanship and operation. Rework mock up as required to produce acceptable work. The approved shade can be used in the installation.
Submit fire resistance data, flame spread and smoke contribution data.
Provide roller tube that operates smoothly and of sufficient diameter and thickness to prevent excessive deflection. Provide brackets that are appropriate for inside mount. Provide shade cloth meeting the performance described in NFPA 701 , small scale test. Treat steel features for corrosion resistance.
Provide Various Fiber Components with a minimum of 60 percent recycled content.
2.1.1 Manufacturer's Qualifications
Obtain motor-controlled roller shades through one source from a single manufacturer with a minimum of twenty years of experience and minimum of three projects of similar scope and size in manufacturing products comparable to those specified in this section. Furnish manual and motorized shades produced by the same manufacturer to provide matching appearance.
2.1.1 Manually Operated Shades with Single Rollers
2.1.1.1 Chain-and-Clutch Operating Mechanisms
Provide continuous-loop bead chain and clutch that stops shade movement when bead chain is released; shade to be permanently adjusted and lubricated.
2.1.1.2 Bead Chains
Provide bead chain from #10 stainless steel rated to 90 lb. minimum breaking strength with pull chain tensioning device complying with
ANSI/WCMA A100.1
a. Loop Length: Full length of roller shade.
SECTION 12 24 13 Page 3
b. Limit Stops: Allows shade to stop when chain is released. Provide limit stops to prevent shade from being raised or lowered too far.
c. Chain-Retainer Type: Chain tensioner, jamb mounted.
2.1.1.3 Rollers
Provide corrosion-resistant steel or extruded-aluminum tubes of diameters and wall thicknesses required to accommodate operating mechanisms and weights and widths of shade bands indicated without deflection. Provide with permanently lubricated drive-end assemblies and idle-end assemblies designed to facilitate removal of shade cloth for service.
a. Roller Drive-End Location: Right side of interior face of shade.
b. Direction of Shade cloth Roll: Regular, from back (exterior face) of roller.
c. Shade cloth-to-Roller Attachment: Manufacturer's standard method.
Adhesive attachment is not acceptable.
2.1.1.4 Mounting Hardware
Provide corrosion resistant brackets or endcaps compatible with roller assembly, operating mechanism, installation accessories, and mounting location and conditions indicated. Provide hardware that allows for field adjustment or removal of shade roller tube and other operable hardware component without removal of brackets and end or center supports.
2.1.1.5 Shade Cloth
a. Shade Material: Light-filtering fabric: Openness 5 percentLight-blocking fabric.
b. Shade Cloth Bottom (Hem) Bar: Steel or extruded aluminum. Provide shade bar exposed with endcaps and integral light seal at bottom where it meets the sill.
2.1.1.6 Installation Accessories
a. Front Fascia: L-shaped aluminum extrusion to conceal shade roller and hardware that snaps onto end caps without requiring exposed fasteners of any kind. Fascia can be mounted continuously across two or more shade bands. Provide manufacturers standard height fascia as required to conceal roller and shade band assembly when shade is fully open.
b. Exposed Headbox: Rectangular, extruded-aluminum enclosure including front fascia, top and back covers, endcaps, and removable bottom closure. Provide manufacturers standard height fascia as required to conceal roller and shade band assembly when shade is fully open.
c. Endcaps: Extruded aluminum with universal design suitable for mounting to window mullions. Provide size compatible with roller size. Provide end cap covers matching fascia/headbox finish.
d. Recessed Shade Pocket: Rectangular, extruded-aluminum enclosure designed for recessed ceiling installation; with front, top, and
SECTION 12 24 13 Page 4 back formed as one piece, end plates, and removable bottom closure panel. Provide manufacturers standard height fascia as required to conceal roller and shade band assembly when shade is fully open. Provide pocket with lip at lower edge to support acoustical ceiling panel.
2.1.1.7 Room Darkening Shades
Provide room darkening (black-out) window shades designed to eliminate all visible light gaps when shades are fully closed and conform with the following:
a. Provide roller tube made of aluminum. Provide shop fabricated light traps consisting of a head box to house the roller shade, and U-shaped channels to serve as guides for the shade along the sides and to receive the bottom edge of the shade along the sill.
b. Provide light trap made of sheet steel having a minimum thickness of 22 gauge or anodized, extruded, aluminum. Provide legs of the channels not less than 1-3/4 inches long and separated by the minimum distance that permits free operation of the shade. Edges of light trap coming into contact with the shade cloth are smooth pile light seal. The exposed face of the head box is hinged or removable for access to the shade roller. The interior or unexposed surfaces of the light trap have a finish coat of flat black enamel. The exposed portions of the light trap have a factory-applied priming coat of gray paint.
c. Provide type of cloth for blackout purposes. Provide shade from a single piece of PVC polyester.
d. Fit the bottom edge of the shade with a steel operating bar. Shades to engage positively with bottom rail through operating bar or chain pull. Paint bars with flat black enamel. Make pull cords of No. 4 braided nylon or beaded chain having not less than 175 pounds breaking strength.
2.1.2 Manually Operated Shades with Dual Rollers
2.1.2.1 Chain-and-Clutch Operating Mechanisms
Provide continuous-loop bead chain and clutch that stops shade movement when bead chain is released; shade to be permanently adjusted and lubricated.
2.1.2.2 Bead Chains
Provide bead chain from #10 stainless steel rated to 90 lb. minimum breaking strength with pull chain tensioning device complying with ANSI/WCMA A100.1 . Provide positive mechanical engagement of drive mechanism to shade roller tube. Center bead chain placement for right or left- hand operation.
a. Loop Length: Full length of roller shade.
b. Limit Stops: Allows shade to stop when chain is released. Provide limit stops to prevent shade from being raised or lowered too far.
c. Chain-Retainer Type: Clip, jamb mount.
SECTION 12 24 13 Page 5
2.1.2.3 Rollers
Provide corrosion-resistant steel or extruded-aluminum tubes of diameters and wall thicknesses required to accommodate operating mechanisms and weights and widths of shade bands indicated without deflection. Provide with permanently lubricated drive-end assemblies and idle-end assemblies designed to facilitate removal of shade bands for service.
a. Dual Shade-Roller Mounting Configuration: Side by Side.
b. Inside Roller: Drive-End Location: Right side of interior face of shade. Direction of Shade cloth Roll: Regular, from back (exterior face) of roller.
c. Outside Roller: Drive-End Location: Right side of interior face of shade. Direction of Shade cloth Roll: Regular, from back (exterior face) of roller .
d. Shade cloth-to-Roller Attachment: Manufacturer's standard method.
Adhesive attachment is not acceptable.
2.1.2.4 Mounting Hardware
Provide corrosion resistant brackets or endcaps compatible with roller assembly, operating mechanism, installation accessories, and mounting location and conditions indicated. Provide hardware that allows for field adjustment or removal of shade roller tube and other operable hardware component without removal of brackets and end or center supports.
2.1.2.5 Inside Shade Cloth
a. Shade Material: Light-blocking fabric.
b. Shade Cloth Bottom (Hem) Bar: Steel or extruded aluminum. Provide shade bar exposed with endcaps and integral light seal at bottom where it meets the sill.
2.1.2.6 Outside Shade Cloth
a. Shade Material: Light-blocking fabric.
b. Shade Cloth Bottom (Hem) Bar: Steel or extruded aluminum. Provide shade bar exposed with endcaps and integral light seal at bottom where it meets the sill.
2.1.2.7 Installation Accessories
a. Front Fascia: L-shaped aluminum extrusion to conceal shade roller and hardware that snaps onto end caps without requiring exposed fasteners of any kind. Fascia can be mounted continuously across two or more shade bands. Provide manufacturers standard height fascia as required to conceal roller and shade band assembly when shade is fully open.
b. Exposed Headbox: Rectangular, extruded-aluminum enclosure including front fascia, top and back covers, endcaps, and removable bottom closure. Provide manufacturers standard height fascia as required to conceal roller and shade band assembly when shade is fully open.
SECTION 12 24 13 Page 6
c. Endcaps: Extruded aluminum with universal design suitable for mounting to window mullions. Provide size compatible with roller size. Provide end cap covers matching fascia/headbox finish.
d. Recessed Shade Pocket: Rectangular, extruded-aluminum enclosure designed for recessed ceiling installation; with front, top, and back formed as one piece, end plates, and removable bottom closure panel.
Provide manufacturers standard height fascia as required to conceal roller and shade band assembly when shade is fully open. Provide pocket with lip at lower edge to support acoustical ceiling panel.
2.1.2.8 Room Darkening Shades
Provide room darkening (black-out) window shades designed to eliminate all visible light gaps when shades are fully closed, and conform with the following:
a. Provide roller tube made of aluminum. Provide shop fabricated light traps, consisting of a head box to house the shade roller, and U-shaped channels to serve as guides for the shade along the sides and to receive the bottom edge of the shade along the sill.
b. Provide light trap made of sheet steel having a minimum thickness of 22 gauge or anodized, extruded, aluminum. Provide legs of the channels not less than 1-3/4 inches long and separated by the minimum distance that permits free operation of the shade. Edges of light trap coming into contact with the shade cloth are smooth pile light seal. The exposed face of the head box is hinged or removable for access to the shade roller. The interior or unexposed surfaces of the light trap have a finish coat of flat black enamel. The exposed portions of the light trap have a factory-applied priming coat of gray paint.
c. Provide type of cloth for blackout purposes. Provide shade from a single piece of PVC polyester.
d. Fit the bottom edge of the shade with a steel operating bar. Shades to engage positively with bottom rail through operating bar or chain pull. Paint bars with flat black enamel. Make pull cords of No. 4 braided nylon or beaded chain having not less than 175 pounds breaking strength.
2.2 COLOR
Provide color, pattern and texture for metal trim and shade fabric as indicated; colors listed are not intended to limit the selection of equal colors from other manufacturers.
PART 3 EXECUTION
3.1 FIELD MEASUREMENTS
After becoming familiar with details of the work, verify all dimensions in the field, and advise the Contracting Officer of any discrepancy before performing the work.
3.2 INSTALLATION
Do not install building construction materials that show visual evidence
SECTION 12 24 13 Page 7 of biological growth.
Provide roller window shades, complete with necessary brackets, fittings, and hardware as indicated.
Perform installation in accordance with the approved detailed drawings and manufacturer's installation instructions. Install units level, plumb, secure, and at proper height and location relative to window units.
Provide and install supplementary or miscellaneous items in total, including clips, brackets, or anchorages incidental to or necessary for a sound, secure, and complete installation. Do not start installation until completion of room painting and finishing operations.
3.3 CLEAN-UP
Upon completion of the installation, clean window treatments and exposed components as recommended by manufacturer. Adjust window treatment for form and appearance and proper operating condition. Repair or replace damaged units as directed by the Contracting Officer. Isolate metal parts from direct contact with concrete, mortar, or dissimilar metals. Ensure shades installed in recessed pockets can be removed without disturbing the pocket. The entire shade, when retracted, is contained inside the pocket. For shades installed outside the jambs and mullions, overlap each jamb and mullion 0.75 inch or more when the jamb and mullion sizes permit. Include all hardware, brackets, anchors, fasteners, and accessories necessary for a complete, finished installation.
-- End of Section --
SECTION 12 24 13 Page 8
| 12 24 13 - ROLLER WINDOW SHADES |
| PART 1 GENERAL |
| 1.1 REFERENCES |
| 1.2 SUBMITTALS |
| 1.3 QUALITY ASSURANCE |
| 1.3.1 Qualifications |
| 1.3.1.1 Installer's Qualifications |
| 1.3.2 Flammability Requirements |
| 1.3.3 Electrical Requirements |
| 1.3.4 Anti-Microbial Requirements |
| 1.4 DELIVERY, STORAGE, AND HANDLING |
| 1.5 WARRANTY |
| PART 2 PRODUCTS |
| 2.1 WINDOW SHADES |
| 2.1.1 Manually Operated Shades with Single Rollers |
| 2.1.1.1 Chain-and-Clutch Operating Mechanisms |
| 2.1.1.2 Bead Chains |
| 2.1.1.3 Rollers |
| 2.1.1.4 Mounting Hardware |
| 2.1.1.5 Shade Cloth |
| 2.1.1.6 Installation Accessories |
| 2.1.1.7 Room Darkening Shades |
| 2.1.2 Manually Operated Shades with Dual Rollers |
| 2.1.2.1 Chain-and-Clutch Operating Mechanisms |
| 2.1.2.2 Bead Chains |
| 2.1.2.3 Rollers |
| 2.1.2.4 Mounting Hardware |
| 2.1.2.5 Inside Shade Cloth |
| 2.1.2.6 Outside Shade Cloth |
| 2.1.2.7 Installation Accessories |
| 2.1.2.8 Room Darkening Shades |
2.2 COLOR
| PART 3 EXECUTION |
| 3.1 FIELD MEASUREMENTS |
| 3.2 INSTALLATION |
| 3.3 CLEAN-UP |