ET601 - TELECOMM RISER DIAGRAM.pdf

PDF 93 KB Posted

Attached to
WVA Fire Station Construction Acquisition Federal contract opportunity
Solicitation number
W912DS25RA009
Issued by
Department of the Army Corps of Engineers Engineering District New York

About this file

This document is a Telecomm Riser Diagram detailing the telecommunications infrastructure and cable routing for a multi-floor facility. The diagram illustrates comprehensive cable management, including fiber optic and copper cable installations across different rooms such as the Main Telecom Room (TER), 2nd Floor TR Room, UPS Room, and Dispatch Area. Key specifications include: (1) 24-strand single mode and (1) 12-strand multi-mode fiber optic service entrance cables, a 50-pair CAT 3 copper backbone, a 600-pair outside plant copper service entrance cable to manhole MH-44, and multiple 4" EMT conduit sleeves penetrating fire-rated partitions. The diagram also shows grounding requirements with primary and secondary bonding busbars, cable ladder trays, network/data racks, analog/voice racks, and provisions for spare conduits, ensuring a structured and organized telecommunications infrastructure design.

View the file

Other files for this federal contract opportunity

Other files attached to WVA Fire Station Construction Acquisition, newest first.
File Type Posted
01 45 00.15 10.pdf PDF
Solicitation Amendment W912DS25RA009_0009(final).pdf PDF
Solicitation Amendment W912DS25RA009_0008 (final).pdf PDF
Amendment W912DS25RA0090007.pdf PDF
Solicitation Amendment W912DS25RA009 0006.pdf PDF
01 50 00.pdf PDF
Solicitation Amendment W912DS25RA0090005.pdf PDF
FINAL_GeotechnicalReport_WatervlietArsenal_Rev1 8-7-23.pdf PDF
WVA Fire Station A-604 20250814.pdf PDF
25-08-11_I-601 and I-602.pdf PDF
09 51 00.pdf PDF
Solicitation Amendment W912DS25RA0090004 SF 30.pdf PDF
WVA Fire Station A-602 20250814.pdf PDF
FINAL_GeotechnicalReport_WatervlietArsenal_Rev1 8-7-23.pdf PDF
08 71 00.pdf PDF
MI703.pdf PDF
ET-601 - TELECOMM RISER DIAGRAM.pdf PDF
ES103 - ELECTRICAL - SITE PLAN - POWER -TELECOMMUNICATIONS.pdf PDF
12 24 13.pdf PDF
WVA Fire Station A-603 20250801.pdf PDF
WVA Fire Station A-511 20250730.pdf PDF
WVA Fire Station A-510 20250730.pdf PDF
WVA Fire Station A-310 20250730.pdf PDF
WVA Fire Station A-123 20250730.pdf PDF
AHJ Interpretation - FP Quals.pdf PDF
07 21 16.pdf PDF
07 21 13.pdf PDF
WVA Fire Station A-602 20250801.pdf PDF
WVA Fire Station A-507 20250730.pdf PDF
WVA Fire Station A-501 20250730.pdf PDF
Solicitation Amendment W912DS25RA009 0003.pdf PDF
06 41 16.00 10.pdf PDF
01 45 00.pdf PDF
WVA Fire Station A-121 20250730.pdf PDF
WVA Fire Station A-503 20250730.pdf PDF
WVA Fire Station A-122 20250730.pdf PDF
WVA Fire Station JA Plymovent Vehicle Exhaust System_sOAS.pdf PDF
WVA Fire Station JA Simplex Fire Alarm System_sOAS.pdf PDF
Solicitation Amendment W912DS25RA009 0002.pdf PDF
Attendance List 21 July 2025.pdf PDF
Site Visit Photos.pdf PDF
W912DS25RA009 Amendment 0001.pdf PDF
CID PACKAGE.pdf PDF
Solicitation - W912DS25RA009(4).pdf PDF
WVA Fire Station - Drawings - RTA 20250624.pdf PDF
WVA-FIRESTATION_RTA_SPEC_07-11-2025.pdf PDF
Show all 46

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROVIDE A 20 FT SERVICE LOOP

FOR FIBER OPTIC CABLES

IN THE BACKBOARD WALL FIELD

4" EMT CONDUIT SLEEVES

PENETRATING FIRE RATED

PARTITION

TYPICAL

FIRE RATED

PARTITION

CABLE LADDER TRAY

SEE SHT. EG-501

FOR GROUNDING AND

BONDING REQUIREMENTS

PRIMARY (MAIN) GROUNDING BUSBARFLOOR

(1) 24 ST OSP RATED SINGLE

MODE FIBER OPTIC SERVICE + (1) 12 ST

MULTI MODE FIBER OPTIC SERVICE (FOR

THE FIRE CENTRAL ALARM SYSTEM)

ENTRANCE CABLES

VIA VERTICAL LADDER RACK TRAY

50-PAIR CAT 3

COPPER BACKBONE

VIA RACKS & CABLE

MANAGEMENT

(1)-600 PAIR TYPE PE-89

#24AWG OUTSIDE PLANT

COPPER SERVICE

ENTRANCE CABLE TO

MANHOLE MH-44.

(SEE SHT. ES-103

FOR CONTINUATION)

600 PAIR

PROTECTOR

BLOCKS

110-TYPE

BLOCKS

100-PAIR

PLYWOOD BACKBOARD

SPARE 4"C, EMT

CAPPED IN

BOTH TER AND

2ND FL TR ROOM

PBB

CABLE TRAY (WIREMESH TYPE)

TRANSITION VERTICAL

OFFSET SECTION

4" 4" 7 8 9 16 10 11

W

ACS/CCTV

RACK

NETWORK/

DATA

RACK

4"

ANALOG/

VOICE RACK

1 1 1

4 4 4

DD FL W

12 12 12

4" 4"

SPARE

4" 4"

(3) 4"C

TO 2ND FL

TR ROOM

4" EMT CONDUIT SLEEVES

PENETRATING FIRE RATED

PARTITION

TYPICAL

FIRE RATED

PARTITION

CABLE LADDER TRAY

SEE SHT. EG-501

FOR GROUNDING AND

BONDING REQUIREMENTS

SECONDARY BONDING BUSBAR GROUNDING BUSBARFLOOR

SBB

CABLE TRAY (WIREMESH TYPE)

TRANSITION VERTICAL

OFFSET SECTION

7 8 9 16 10 11

W

NETWORK/

DATA

RACK

ANALOG/

VOICE RACK

1 1

4 4 5

DD FL W

12 12

MAIN TELECOM ROOM (TER)

2ND FL TR ROOM

(TYP)

CABLE TRAY (WIREMESH TYPE)

CABLE TRAY (WIREMESH TYPE)

DISPATCH

AREA

NETWORK

RACK

UPS ROOM

4" 4" 4"

50-PAIR CAT 3

COPPER BACKBONE

FROM MAIN TER

(1)-24 ST SM FOC

FROM MAIN TER RM

DR

DRSPARE

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

Fi le

P at h:

Pl ot D at e:

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

R :\d m s3

\W

VA

-F S-

D M

M -E

-M D

L.

rv t 9/

/2

3:

:3

PM

ET601

TE

LE

C O

M M

R

IS

ER

D

IA

G

R

AM

W

AT

ER

VL

IE

T

AR

SE

N

AL

N Y

N

EW

Y O

R K

D

IS

TR

IC

T

F

ED

ER

AL

P

LA

ZA

N

EW

Y

O R

K, N

Y

M .D

AV

IS

M .D

AV

IS

M .D

AV

IS

M .G

IU

R

G

IU

AP

R

IL

9, R

TA

S U

BM

IS

SI

O

N

C

O M

PA

N

Y

FI

R E

ST

AT

IO

N

PN

2-POST 19"WX84"H EQUIPMENT RACK.

BACKBONE FIBER PATCH PANEL, 2 RU, 48 PORT WITH FUSION SPLICED

PIGTAIL (10 FT) CASSETTES.

FIBER PATCH PANEL, 2RU, WITH FUSION SPLICED PIGTAIL CASSETTES

FOR TERMINATION OF THE FIBER OPTIC LOOP FOR THE EXISTING WVA

CENTRAL FIRE ALARM SYSTEM (SIMPLEX),

QUAD AND SPECIAL OUTLETS (110VAC, NEMA L5-20R, NEMA L6-30R,ETC)

FOR EQUIPMENT CABINETS AND RACKS SHALL BE MOUNTED ABOVE

CABINETS. SEE SHT. EP-401 FOR ADDITIONAL INFORMATION.

HORIZONTAL CAT 6 & CAT 6A VOICE AND DATA CABLES ROUTED IN

CABLE TRAY THEN IN CONDUIT TO THE OUTLETS.

COORDINATE SLEEVE PENETRATIONS WITH STRUCTURAL AND ARCH

DISCIPLINES. FIRE SEAL ALL PENETRATIONS THROUGH FIRE RATED

PARTITIONS.

TYPICAL WALL MOUNTED DATA/VOICE CAT 6 OUTLET WITH (3) CAT 6

OUTLETS. PROVIDE WITH (3) CAT 6 CABLES IN 1 1/4"C ROUTED TO THE

OUTLET.

TYPICAL DUAL CAT 6 DATA OUTLET FOR BAS SYSTEM WITH 2 CAT 6

CABLES IN 1 1/4"C.

TYPICAL FLOOR MOUNTED DUAL CAT 6 OUTLET IN COMBINATION

POWER/DATA FLOOR BOX WITH (4) CAT 6 CABLES IN 1 1/4"C TO THE

FLOOR BOX. ALL CAT 6 CABLES SHALL BE WEATHERPROOF

TYPICAL WALL MOUNTED TELEPHONE CAT 6 OUTLET WITH (1) CAT 6

CABLE IN 1"C.

TYPICAL WIRELESS ACCESS POINT OUTLET WITH (2) CAT 6A JACKS.

PROVIDE WITH (2) CAT 6A CABLES IN 1 1/4"C.

PROVIDE VERTICAL RACK MOUNTED POWER DISTRIBUTION UNITS

(RPDUs).

PROVIDE GROUNDING BUSHING AT CONDUIT END,

AND GROUND TO CABLE TRAY WITH #6 AWG CONDUCTOR.

PROVIDE (4) 4-INCH CONDUIT DUCTBANK SYSTEM. PROVIDE THREE (3)

3X3" MULTICELL FABRIC MESH INNERDUCT IN ONE OF THE 4-INCH

CONDUIT FOR FIBER OPTIC CABLE ROUTING. 200# PULL STRING SHALL

BE PROVIDED IN EACH INNERDUCT AND EACH CONDUIT. SEE SHT.

ES-101 FOR CONTINUATION OF SERVICE CONDUIT.

DORM ROOM WALL MOUNTED DATA/VOICE CAT 6 OUTLET WITH (2) CAT

6 OUTLETS. PROVIDE WITH (2) CAT 6 CABLES IN 1 1/4"C ROUTED TO THE

OUTLET. .

12 ST SM FOC BACKBONE CABLE (PLENUM RATED), TYPE OS-2. ROUTE

IN ORANGE INNERDUCT IN THE CABLE TRAY.

BACKBONE CABLE PATCH PANELS. COPPER BACKBONE SHALL BE

TERMINATED ONE PAIR PER PORT (PINS 4 & 5), EXCEPT FOR PORT #48

TERMINATE 2-PAIR. PROVIDE QUANTITY OF PATCH PANELS AS

REQUIRED TO TERMINATE THE 50 PAIR CABLE.

1.FOR ELECTRICAL NOTES, ABBREVIATIONS, AND SYMBOLS REFER TO

DRAWING E-001, E-002 & ET-001.

2. PROVIDE ALL PATCH PANELS AS REQUIRED TO SUFFICIENTLY

TERMINATE ALL CABLES SPECIFIED.

3. DRAWINGS ARE DIAGRAMMATIC ONLY. EXACT ARRANGEMENT FOR

EQUIPMENT AND PATCH PANELS SHALL BE COORDINATED AND

OPTIMIZED IN THE FIELD.

4. MOST JUNCTION BOXES AND RACEWAYS ARE NOT SHOWN. ALL

INSTALLATION SHALL BE IN ACCORDANCE WITH NATIONAL ELECTRICAL

CODE, UFC 3-580-01 CRITERIA, AND TIA STANDARDS AND

REQUIREMENTS.

5. NOT MORE THAN (2) 90-DEGREE TURNS SHALL BE ALLOWED ON ANY

CABLE ROUTES OR PULLS WITHOUT PROPER INSTALLATION OF PULL

BOXES OR JUNCTION BOXES.

6. ALL BACKBONE CONDUITS FOR TELECOM ASSOCIATED CABLES SHALL

BE PROVIDED WITH 3X3" CELL FABRIC INNERDUCTS, AND WITH PULL

STRINGS IF IT IS A SPARE CONDUIT.

7. WHILE NOT SHOWN, CABLES FROM SERVICE ENTRANCE CONDUITS TO

TELCOM RACKS SHALL BE VIA CABLE TRAYS AND SUPPORT AS

REQUIRED BY UFC 3-580-01 CRITERIA.

8. HORIZONTAL DISTRIBUTION CAT 6 CABLES SHALL BE GROUPED IN

BUNDLES OF 25 CABLES MAXIMUM, AND PROVIDED WITH VELCRO CABLE

TIES IN THE CABLE TRAY. CABLE TIES SHALL BE PROVIDED AT

INTERVALS OF EVERY 25 LF.

9. ALL CATEGORY 6 & 6A CABLES SHALL BE PLENUM RATED.

10. ALL FIBER OPTIC CABLES SHALL BE PLENUM RATED.

11. SEE TELECOMM FLOOR PLAN FOR QUANTITY OF OUTLETS AND

DEVICES.

12. THIS CONTRACTINCLUDES THE INSTALLATION OF THE PATHWAYS,

CABLING, CAT 6A JACKS AND BOXES REQUIRED FOR THE FUTURE

INSTALLATION OF WIRELESS ROUTERS. THE WIRELESS

ROUTERS WILL BE PROVIDED BY OTHERS.

DRAWING KEYED NOTES

GENERAL NOTES

NTSET601

1 TELECOMM RISER DIAGRAM

(TYP)

R ev is ed p er a m en dm en t

/0 4/

R ev is ed p er a m en dm en t

/1 1/

Sheets
ET601 - TELECOMM RISER DIAGRAM

File details come from the government source that posted it. Updated .