ATTACHMENT 9 SPECS V1 ADDENDUM.pdf

PDF 190 KB Posted

Attached to
Construct Mission Training Center (MTC) Facility Federal contract opportunity
Solicitation number
W50S78-24-B-0001
Issued by
Department of the Army National Guard

About this file

This document appears to be an addendum to the specifications for a federal contract opportunity to construct a Mission Training Center (MTC) facility for the Texas Air National Guard at Joint Base San Antonio - Lackland.

The key details are:

  • The addendum revises the door hardware specifications, specifically removing the BEST lockset system and revising the number of tumblers.
  • The overall contract is for the construction of a 15,200 square foot MTC facility, including demolition, site work, utilities, HVAC, plumbing, electrical, and other associated work.
  • The contract will be a single firm-fixed price award set aside for small businesses. The North American Industry Classification System (NAICS) code is 236220 with a $45 million size standard.
  • The project includes a base bid and 8 options such as permeable pavement, landscaping, floor coatings, and special signage.
  • Several brand name items are specified for compatibility with existing installation systems.
  • Solicitation number is W50S78-24-B-0001, with a 540 calendar day period of performance.

View the file

Other files for this federal contract opportunity

Other files attached to Construct Mission Training Center (MTC) Facility, newest first.
File Type Posted
C-301-REMOVAL PLAN.pdf PDF
S-002-TYPICAL DETAILS.pdf PDF
SF101-LOW ROOF FRAMING PLAN.pdf PDF
S-001-GENERAL NOTES.pdf PDF
New Utilities to East.pdf PDF
M-501 DETAILS.pdf PDF
AE501-SECTION DETAILS.pdf PDF
AE305-WALL SECTIONS.pdf PDF
C-201-STORMWATER POLLUTION PREVENTION PLAN.pdf PDF
C-601-UTILITY PLAN.pdf PDF
SF102-HIGH ROOF FRAMING PLAN.pdf PDF
G-003-CODE AND LIFE SAFETY PLAN.pdf PDF
M-702 SCHEDULES.pdf PDF
M-701 SCHEDULES.pdf PDF
AE601-ROOM FINISH SCHEDULE AND GLAZING TYPES AND MISC DETAILS.pdf PDF
AE303-WALL SECTIONS.pdf PDF
23 05 48.19 - SEISMIC BRACING FOR HVAC.pdf PDF
23 05 48.00 40 - VIBRATION CONTROLS FOR HAC PIPING AND EQUIPMENT.pdf PDF
11 94 10 - Rooftop Fall Protection Anchors.pdf PDF
000 TABLE OF CONTENTS.pdf PDF
01 45 35 - Special Inspections.pdf PDF
C-401-PROPOSED PLAN.pdf PDF
C-602-DRAINAGE SCHEDULE AND DETAILS.pdf PDF
ES101-ELECTRICAL SITE PLAN.pdf PDF
AE401-ENLARGED PLANS AND DETAILS.pdf PDF
AE503-SECTION DETAILS.pdf PDF
01 45 00 - Quality Control.pdf PDF
Amendment 0004 - 17 Aug 2024.pdf PDF
W50S78-24-B-0001 - Mission Training Center Amendment 0003.pdf PDF
Attachment 14 - Geotechnical report-TX ANG Mission Training Center B-3.pdf PDF
MTC RFI log.pdf PDF
W50S7824B0001 - MTC - Amendment 02 - 20240829.pdf PDF
MFR Mission Training Center - 2nd Site Visit Pre-Propsal Conference Minutes.pdf PDF
Pre_Bid_Site Visit_MTC_Attendance_Sheet 27_Aug _2024.pdf PDF
Pre-Proposal Site Visit Slides - MTC 27 Aug 24.pptx PPTX presentation
2024.08.21_TX-ANG_149TH MISSION TRAINING CENTER_REVISED B3_VOL 1 SPECIFICATIONS.pdf PDF
MTC RFI log.pdf PDF
Pre-Proposal Site Visit Slides - MTC 20 Aug 24 (002).pptx PPTX presentation
Pre_Bid_Site Visit_MTC_Attendance_Sheet 20_Aug _2024.pdf PDF
Attachment 6_Industrial Security.pdf PDF
Attachment 7_ACCESS AND STAGING SITE PLAN.pdf PDF
Attachment 5_STRUCTURAL INTERIOR DESIGN.pdf PDF
JA Nm Brand DDC Redacted.pdf PDF
JA Nm Brand Falcon Redacted.pdf PDF
W50S78-24-B-0001 - Mission Training Center Solicitation.pdf PDF
2024.08.15_TX-ANG_149TH MISSION TRAINING CENTER_REVISED B3_DRAWINGS.pdf PDF
JA Nm Brand Monaco Redacted.pdf PDF
JA Nm Brand Trane HVAC Redacted.pdf PDF
2024.08.15_TX-ANG_149TH MISSION TRAINING CENTER_REVISED B3_VOL 1 SPECIFICATIONS.pdf PDF
JA Nm Brand Vindicator Sys Redacted.pdf PDF
Show all 50

Construct Mission Training Center (MTC) Facility has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FSB | fsb-ae.com

ADDENDUM NO. 01

Date: 21 August 2024

To: ALL BIDDERS OF RECORD

From: Frankfurt-Short-Bruza Associates, P.C.

5801 N. Broadway Ext., Suite 500 Oklahoma City, OK 73118

Subject: KELL189014: Mission Training Center, TX/ANG, JBSA Lackland, San Antonio, TX

FSB Project No.: 20190310

NOTE: This Addendum forms a part of the Contract Documents and modifies the Original Documents dated 2 August 2024.

Acknowledge receipt of this Addendum in the space provided on the Bid Form. Failure to do so may subject the Bidder to disqualification.

ATTACHMENTS

Items in this addendum take precedence over the original bid documents. Items not specifically revised remain in effect. This addendum consists of (1) pages and the following attachments:

Specifications:

08 71 00 – DOOR HARDWARE

MODIFICATIONS TO THE SPECIFICATIONS

ITEM 01.1-1 Refer to attached Specification Section 08 71 00 – DOOR HARDWARE, dated 21 August 2024:

A. Specification Section 08 71 00 is hereby revised and re-issued in its entirety to remove BEST lockset system as specific product & revise number of tumblers. Replace Section 08 71 00 dated 2 August 2024 with attached revised

Specification Section 08 71 00dated 21 August 2024.

NGBJV-TX ANG MISSION TRAINING CENTER PN KELL189014

KELLY FIELD ANNEX 100% CONTRACT DOCUMENTS, 21 AUGUST 2024

SECTI ON 08 71 00

DOOR HARDWARE

02/ 16

PART 1 GENERAL

1. 1 REFERENCES

The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o i n t he t ext by t he basi c desi gnat i on onl y.

ASTM I NTERNATI ONAL ( ASTM)

ASTM E283 ( 2019) St andar d Test Met hod f or Det er mi ni ng t he Rat e of Ai r Leakage Thr ough Ext er i or Wi ndows, Cur t ai n Wal l s, and Door s Under Speci f i ed Pr essur e Di f f er ences Acr oss t he Speci men

ASTM F883 ( 2013; R 2022) St andar d Per f or mance Speci f i cat i on f or Padl ocks

BUI LDERS HARDWARE MANUFACTURERS ASSOCI ATI ON ( BHMA)

ANSI / BHMA A156. 1 ( 2021) But t s and Hi nges

ANSI / BHMA A156. 2 ( 2022) Bor ed and Pr eassembl ed Locks and Lat ches

ANSI / BHMA A156. 13 ( 2022) Mor t i se Locks & Lat ches Ser i es 1000

ANSI / BHMA A156. 16 ( 2023) Auxi l i ar y Har dwar e

ANSI / BHMA A156. 18 ( 2020) Mat er i al s and Fi ni shes

ANSI / BHMA A156. 19 ( 2013) Power Assi st & Low Ener gy Power Oper at ed Door s

ANSI / BHMA A156. 21 ( 2019) Thr eshol ds

ANSI / BHMA A156. 22 ( 2021) Gasket i ng

ANSI / BHMA A156. 25 ( 2013) El ect r i f i ed Locki ng Devi ces

ANSI / BHMA A156. 26 ( 2012) Cont i nuous Hi nges

ANSI / BHMA A156. 3 ( 2020) Exi t Devi ces

ANSI / BHMA A156. 36 ( 2010) Auxi l i ar y Locks

ANSI / BHMA A156. 4 ( 2013) Door Cont r ol s - Cl oser s

ANSI / BHMA A156. 5 ( 2020) Cyl i nder and I nput Devi ces f or Locks

ANSI / BHMA A156. 6 ( 2021) Ar chi t ect ur al Door Tr i m

SECTI ON 08 71 00 Page 1

Addendum #1 - 08/21/2024

Eisner, Kelly Cloud

ANSI / BHMA A156. 7 ( 2016) Templ at e Hi nge Di mensi ons

ANSI / BHMA A156. 8 ( 2021) Door Cont r ol s - Over head St ops and Hol der s

NATI ONAL FI RE PROTECTI ON ASSOCI ATI ON ( NFPA)

NFPA 101 ( 2021; TI A 21- 1) Li f e Saf et y Code

NFPA 252 ( 2022) St andar d Met hods of Fi r e Test s of Door Assembl i es

NFPA 70 ( 2023; ERTA 7 2023; TI A 23- 15) Nat i onal El ect r i cal Code

NFPA 72 ( 2022; ERTA 22- 1) Nat i onal Fi r e Al ar m and Si gnal i ng Code

NFPA 80 ( 2022) St andar d f or Fi r e Door s and Ot her Openi ng Pr ot ect i ves

STEEL DOOR I NSTI TUTE ( SDI / DOOR)

SDI / DOOR A250. 8 ( 2023) Speci f i cat i ons f or St andar d St eel Door s and Fr ames

U. S. GENERAL SERVI CES ADMI NI STRATI ON ( GSA)

FF- L- 2740B Feder al Speci f i cat i on, Locks, El ect r omechani cal .

FF- L- 2890C Feder al Speci f i cat i on, Lock Ext ensi ons.

U. S. NATI ONAL ARCHI VES AND RECORDS ADMI NI STRATI ON ( NARA)

36 CFR 1191 Amer i cans wi t h Di sabi l i t i es Act ( ADA) Accessi bi l i t y Gui del i nes f or Bui l di ngs and Faci l i t i es; Ar chi t ect ur al Bar r i er s Act ( ABA) Accessi bi l i t y Gui del i nes

UNDERWRI TERS LABORATORI ES ( UL)

UL Bl d Mat Di r ( updat ed cont i nuousl y onl i ne) Bui l di ng Mat er i al s Di r ect or y

1. 2 SUBMI TTALS

Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" desi gnat i on;

submi t t al s not havi ng a " G" desi gnat i on ar e f or Cont r act or Qual i t y Cont r ol appr oval . Submi t t al s wi t h an " S" ar e f or i ncl usi on i n t he Sust ai nabi l i t y Not ebook, i n conf or mance wi t h Sect i on 01 33 29 SUSTAI NABI LI TY REPORTI NG.

Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00 SUBMI TTAL

PROCEDURES:

SD- 02 Shop Dr awi ngs

Manuf act ur er ' s Det ai l Dr awi ngs; G

Ver i f i cat i on of Exi st i ng Condi t i ons; G

SECTI ON 08 71 00 Page 2

Har dwar e Schedul e; G

Keyi ng Syst em; G

SD- 03 Pr oduct Dat a

Har dwar e I t ems; G

SD- 08 Manuf act ur er ' s I nst r uct i ons

I nst al l at i on

SD- 10 Oper at i on and Mai nt enance Dat a

Har dwar e Schedul e I t ems, Dat a Package 1; G

SD- 11 Cl oseout Submi t t al s

Key Bi t t i ng

1. 3 SHOP DRAWI NGS

Submi t manuf act ur er ' s det ai l dr awi ngs i ndi cat i ng al l har dwar e assembl y component s and i nt er f ace wi t h adj acent const r uct i on. I ndi cat e power component s and wi r i ng coor di nat i on f or el ect r i f i ed har dwar e. Base shop dr awi ngs on ver i f i ed f i el d measur ement s and i ncl ude ver i f i cat i on of exi st i ng condi t i ons.

1. 4 PRODUCT DATA

I ndi cat e f i r e- r at i ngs at appl i cabl e component s. Pr ovi de document at i on of ABA/ ADA accessi bi l i t y compl i ance of appl i cabl e component s, as r equi r ed by 36 CFR 1191 Appendi x D - Techni cal .

1. 5 HARDWARE SCHEDULE

Pr epar e and submi t har dwar e schedul e i n t he f ol l owi ng f or m:

Har dwar e I t em

Quant i t y Si ze Ref er ence Publ i -cat i on Type No.

Fi ni sh Mf r Name and Cat al og No.

Key Cont r ol Symbol s

UL Mar k ( I f f i r e-r at ed and l i st ed)

BHMA

Fi ni sh Desi g-nat i on

I n addi t i on, submi t har dwar e schedul e dat a package 1 i n accor dance wi t h Sect i on 01 78 23 OPERATI ON AND MAI NTENANCE DATA.

1. 6 KEY BI TTI NG CHART REQUI REMENTS

Coor di nat e door cyl i nder and keyi ng r equi r ement s wi t h t he Joi nt Base San Ant oni o - Kel l y Annex l ock shop per sonnel , POC i nf or mat i on l i s t ed bel ow i n t hi s speci f i cat i on. Conf i gur e cor es and cut keys t o Joi nt Base San Ant oni o - Kel l y Anne l ock shop speci f i cat i ons and mast er keyi ng st r at egy. Conf i gur ed cor es and cut keys shal l be del i ver ed wi t h key bi t t i ng char t ( s) t o t he Joi nt

SECTI ON 08 71 00 Page 3

Base San Ant oni o - Kel l y Anne l ock shop f or f i nal i nst al l at i on. Fi nal l ockset cor e i nst al l at i on wi l l be conduct ed by El l swor t h AFB per sonnel .

1. 6. 1 Requi r ement s

Submi t key bi t t i ng char t s t o t he Cont r act i ng Of f i cer pr i or t o compl et i on of t he wor k. I ncl ude:

a. Compl et e l i s t i ng of al l keys ( e. g. AA1 and AA2) .

b. Compl et e l i s t i ng of al l key cut s ( AA1- 123456, AA2- 123458) .

c. Tabul at i on showi ng whi ch key f i t s whi ch door .

d. Copy of f l oor pl an showi ng door s and door number s.

e. Li st i ng of 20 per cent mor e key cut s t han ar e pr esent l y r equi r ed i n each mast er syst em.

1. 7 QUALI TY ASSURANCE

1. 7. 1 Har dwar e Manuf act ur er s and Modi f i cat i ons

Pr ovi de, as f ar as f easi bl e, l ocks, hi nges, pi vot s, and cl oser s of one l ock, hi nge, pi vot , or c l oser manuf act ur er ' s make. Modi f y har dwar e as necessar y t o pr ovi de f eat ur es i ndi cat ed or speci f i ed.

1. 7. 2 Key Shop Dr awi ngs Coor di nat i on Meet i ng

1). Access to the new facilities shall be provided with an existing master key system provided by “Best Lock Corporation”.

2). Hardware including cores and keys shall be ordered by the contractor from BEST or an authorized BEST supplier. Contractor shall submit all invoicing detailing quantities of cores and keys ordered for the project. This invoicing should include all extra stock and any additional product needed to convert non BEST hardware that may come from other suppliers/manufacturers such as that supplied with storefront doors or cipher locks. Details on how the keying will be setup will be worked directly between BEST and the Base. Cores and keys will be sent from BEST directly to 9 CES/CENM at 6425 B Street Beale AFB CA 95903 for installation and key turnover to the building users. Cores and keys should be available prior to substantial completion to ensure a smooth transition to the users.

3). Quantities for orders shall be agreed to and approved by 9 CES/CENM prior to any orders being issued by the Contractor. The Contractor will actively work with his subcontractors/suppliers/and BEST directly to resolve any issues with quantities and payments. At no time will any permanent cores and keys be sent to or released to the Contractor. The Contractor will provide and install temporary construction cores and keys for all doors necessary to secure the new facility until the new ones can be installed. Contractor shall have available all control keys so that construction cores and other non-BEST cores can be removed and replaced.

4). All new facility construction will utilize BEST locksets with Coremax brand cores. At no time will generic no label cores or keying

SECTI ON 08 71 00 Page 4

Prior to the submission of the key shop drawing, the Contracting Officer, Contractor, Door Hardware Subcontractor, using Activity and Base Locksmith must meet to discuss and coordinate key requirements for the facility.

Provide, as far as feasible, locks, hinges, pivots, and closers of one lock, hinge, pivot, or closer manufacturer's make. Modify hardware as necessary to provide features indicated or specified.

Addendum #1 - 08/21/2024

Eisner, Kelly Cloud be used

1. 8 DELI VERY, STORAGE, AND HANDLI NG

Del i ver har dwar e i n or i gi nal i ndi v i dual cont ai ner s, compl et e wi t h necessar y appur t enances i ncl udi ng f ast ener s and i nst r uct i ons. Mar k each i ndi v i dual cont ai ner wi t h i t em number as shown on har dwar e schedul e.

Del i ver per manent keys and r emovabl e cor es t o t he Cont r act i ng Of f i cer , ei t her di r ect l y or by cer t i f i ed mai l . Del i ver const r uct i on mast er keys wi t h t he l ocks.

PART 2 PRODUCTS

2. 1 TEMPLATE HARDWARE

Har dwar e appl i ed t o met al door s must be manuf act ur ed usi ng a t empl at e.

Pr ovi de t empl at es t o door and f r ame manuf act ur er s i n accor dance wi t h ANSI / BHMA A156. 7 f or t empl at e hi nges. Coor di nat e har dwar e i t ems t o pr event i nt er f er ence wi t h ot her har dwar e.

2. 2 HARDWARE FOR FI RE DOORS AND EXI T DOORS

Pr ovi de al l har dwar e necessar y t o meet t he r equi r ement s of NFPA 72 f or door al ar ms, NFPA 80 f or f i r e door s, NFPA 101 f or exi t door s, NFPA 252 f or f i r e t est s of door assembl i es, ABA/ ADA accessi bi l i t y r equi r ement s, and al l ot her r equi r ement s i ndi cat ed, even i f such har dwar e i s not speci f i cal l y ment i oned i n par agr aph HARDWARE SCHEDULE. Pr ovi de Under wr i t er s Labor at or i es, I nc. l abel s f or such har dwar e i n accor dance wi t h UL Bl d Mat Di r or equi val ent l abel s i n accor dance wi t h anot her t est i ng l abor at or y appr oved i n wr i t i ng by t he Cont r act i ng Of f i cer .

2. 3 HARDWARE I TEMS

Cl ear l y and per manent l y mar k wi t h t he manuf act ur er ' s name or t r ademar k, hi nges, pi vot s, l ocks, l at ches, exi t devi ces, bol t s and cl oser s wher e t he i dent i f y i ng mar k i s v i s i bl e af t er t he i t em i s i nst al l ed. For c l oser s wi t h cover s, t he name or t r ademar k may be beneat h t he cover . Coor di nat e el ect r i f i ed door har dwar e component s wi t h cor r espondi ng component s speci f i ed i n Di v i s i on 28 ELECTRONI C SECURI TY SYSTEMS ( ESS) .

2. 3. 1 Hi nges

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 1. Pr ovi de hi nges t hat ar e 4- 1/ 2 by 4- 1/ 2 i nch unl ess ot her wi se i ndi cat ed. Const r uct l oose pi n hi nges f or ext er i or door s and r ever se- bevel i nt er i or door s so t hat pi ns wi l l be nonr emovabl e when door i s c l osed. Use BHMA t ype 5111 heavy wei ght ant i f r i c t i on bear i ng hi nges on ext er i or door s and door s exposed t o t he hangar bays. Use BHMA t ype 8111 heavy wei ght ant i f r i c t i on bear i ng hi nges on i nt er i or door s t hat f or m par t of t he bui l di ng c i r cul at i on syst ems, secur e st or age and pr i mar y shop door s. Use BHMA t ype 8112 on pr i mar y of f i ce sui t e door s, conf er ence, br i ef i ng and al l ot her door s not i ncl uded above t hat ar e equi pped wi t h c l oser s. Use BHMA t ype 8131 on al l ot her door s. Ot her ant i f r i c t i on bear i ng hi nges may be pr ovi ded i n l i eu of bal l - bear i ng hi nges.

2. 3. 1. 1 Maxi mum Secur i t y Pi n ( MSP)

ANSI / BHMA A156. 1 Pr ovi de Maxi mum Secur i t y pi ns and secur i t y st uds at al l hi nges i dent i f i ed as " wi t h MSP" i n t he har dwar e schedul e.

SECTI ON 08 71 00 Page 5

2. 3. 1. 2 Non- Removeabl e Pi n ( NRP)

ANSI / BHMA A156. 1 Pr ovi de at al l hi nges i dent i f i ed as " wi t h NRP" i n t he har dwar e schedul e

2. 3. 2 Cont i nuous Hi nges

Wher e cont i nuous hi nges ar e r equi r ed, pr ovi de i n accor dance wi t h

ANSI / BHMA A156. 26.

2. 3. 3 Locks and Lat ches

2. 3. 3. 1 Mor t i se Locks and Lat ches

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 13, Ser i es 1000, Oper at i onal Gr ade 1, Secur i t y Gr ade 2. Pr ovi de mor t i se l ocks wi t h escut cheons not l ess t han 7 by 2- 1/ 4 i nch wi t h a bushi ng at l east 1/ 4 i nch l ong. Cut escut cheons t o f i t cy l i nder s and pr ovi de t r i m i t ems wi t h st r ai ght , bevel ed, or smoot hl y r ounded si des, cor ner s, and edges. PPr ovi de l ever s of mor t i se l ocks wi t h scr ewl ess shanks and no exposed scr ews.

2. 3. 3. 2 Bor ed Locks and Lat ches

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 2, Ser i es 4000, Gr ade 1.

Pr ovi de f act or y i nst al l ed l ead l i ni ng i n l ocks f or l ead - shi el ded door s.

2. 3. 3. 3 Hi gh Secur i t y Combi nat i on Lockset Assembl i es

Pr ovi de compl et e, f unct i onal l ockset assembl y, compl at i bl e wi t h r ef er enced el ect r oni c access cont r ol syst em. Pr ovi de al l st r i kes, pl at es, mount i ng assembl i es, and har dwar e necessar y f or a compl i ant i nst al l at i on under t he r ef er enced st andar ds. Assembl y shal l be compr i sed of t he f ol l owi ng:

2. 3. 3. 4 Pedest r i an Deadbol t Devi ce

Pr ovi de r i m l ockset assembl y compl yi ng wi t h FF- L- 2890C, capabl e of i nt egr at i ng wi t h hi gh secur i t y combi nat i on l ock compl yi ng wi t h FF- L- 2740B.

Lockset shal l al l ow si ngl e- mot i on egr ess f r om secur ed si de of door as def i ned by NFPA 101, al l ow f or access cont r ol syst em i nt egr at i on/ over r i de, as wel l as physi cal key over r i de ( wi t h cor e and key compat i bl e wi t h Joi nt Base San Ant oni o - Kel l y Annex keyi ng syst em) .

2. 3. 3. 5 Hi gh Secur i t y Combi nat i on Lock

Lock shal l conf or m t o FF- L- 2740B, Hi gh Secur i t y l ocks shal l be model el ect r omechani cal combi nat i on uni t appr oved by t he GSA f or use on Cl ass 5 and Cl ass 8 secur i t y vaul t door s. The l ock shal l be i nt er nal l y sel f - power ed such t hat r ot at i on of t he di al i n ei t her di r ect i on pr ovi des al l t he power necessar y t o oper at e t he l ock. The l ock shal l have t hr ee combi nat i on modes: Si ngl e: 1 mi l l i on combi nat i ons; Dual : 500 bi l l i on combi nat i ons; Super vi sor / Subor di nat e: 2 mi l l i on combi nat i ons. A l i mi t ed v i ew Li qui d Cr yst al Di spl ay ( LCD) shal l be pr ovi ded. The l ock shal l be t amper - r esi st ant wi t h dr i l l - r esi st ant di al r i ng mount i ng pl at e and shal l be f ai l secur e agai nst mani pul at i on or at t ack. Vi br at i on and shock shal l meet MI L- STD- 810. Case and bol t st r engt h shal l be 600 l bs mi ni mum i n t wo di r ect i ons. Openi ng and unsuccessf ul at t empt s shal l be r ecor ded.

SECTI ON 08 71 00 Page 6

2. 3. 3. 6 5- But t on Mechani cal Lockset s

ANSI / BHMA A156. 5, Funct i on 40. Lockset pr ovi ded shal l be r at ed f or out door use and be door syst em compat i bl e. Lock shal l be mechani cal , 5- push but t on t ype, wi t h l ever handl e ( bot h s i des of door , unl ess not ed ot her wi se) and keyed cyl i ndr i cal cor e, compat i bl e wi t h Joi nt Base San Ant oni o - Kel l y Annex keyi ng syst em. Lockset shal l be i nst al l ed i n a manner t hat i s per manent , st ur dy, and t hat does not al l ow access t o t he l at ch r el ease f r om t he unsecur e s i de.

2. 3. 3. 7 Auxi l i ar y Locks

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 36, Gr ade 1.

2. 3. 4 Exi t Devi ces

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 3, Gr ade 1. Pr ovi de adj ust abl e st r i kes f or r i m t ype and ver t i cal r od devi ces. Pr ovi de open back st r i kes f or pai r s of door s wi t h mor t i se and ver t i cal r od devi ces. Pr ovi de t ouch bar s i n l i eu of convent i onal cr ossbar s and ar ms. Pr ovi de escut cheons not l ess t han 7 by 2- 1/ 4 i nch.

2. 3. 4. 1 El ect r i c Exi t Devi ces

Pr ovi de el ect r i c act uat ed exi t devi ces wher e i dent i f i ed i n t he har dwar e schedul e. Gr ade and f i ni sh shal l be s i mi l ar t o mechani cal devi ces pr ovi ded t hr oughout t he bui l di ng.

2. 3. 5 Cyl i nder s and Cor es

Provide cylinders and cores for new locks that meet the Base standard of BEST 7 Pin Coremax, with six pin tumblers, including locks provided under other sections of this specification. All locksets with cores shall be BEST or BEST compatible. Rim cylinders and mortise cylinders shall have small format interchangeable cores which are removable by special control keys. Stamp each interchangeable core with a key control symbol in a con-cealed place on the core.

2. 3. 6 El ect r i f i ed Har dwar e

Compl y wi t h t he r equi r ement s of NFPA 70 f or wi r i ng of el ect r i f i ed har dwar e.

2. 3. 6. 1 El ect r i f i ed Mor t i se Locks

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 25, Gr ade 1. Pr ovi de el ect r i f i ed mor t i se l ocks t hat r emai n secur e dur i ng power f ai l ur e.

Pr ovi de f aci l i t y i nt er f ace devi ces t hat use dc power t o ener gi ze sol enoi ds. Pr ovi de sol enoi ds, r esi st er s, and si gnal swi t ches i n accor dance wi t h par agr aph ELECTRI C STRI KES AND FRAME MOUNTED ACTUATORS.

2. 3. 6. 1. 1 Power Tr ansf er Hi nges

Pr ovi de power t r ansf er hi nges wi t h each el ect r i f i ed l ock t hat r out e power and moni t or i ng s i gnal s f r om t he l ockset t o t he door f r ame. Coor di nat e power t r ansf er hi nges wi t h door f r ames.

SECTI ON 08 71 00 Page 7

Addendum #1 - 08/21/2024

Eisner, Kelly Cloud

2. 3. 6. 2 Power Assi st and Low Ener gy Power Oper at ed Door s

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 19, Gr ade 1.

2. 3. 7 Keyi ng Syst em

Pr ovi de an ext ensi on of t he exi st i ng keyi ng syst em. Pr ovi de i nt er changeabl e cor es. Pr ovi de key cabi net as speci f i ed.

2. 3. 8 Lock Tr i m

Pr ovi de cast , f or ged, or heavy wr ought const r uct i on and commer ci al pl ai n desi gn f or l ock t r i m.

2. 3. 8. 1 Lever Handl es

Pr ovi de l ever handl es. Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 3 f or mor t i se l ocks of l ever handl es f or exi t devi ces. Pr ovi de l ever handl e l ocks wi t h a br eakaway f eat ur e ( such as a weakened spi ndl e or a shear key) t o pr event i r r epar abl e damage t o t he l ock when f or ce i n excess of t hat speci f i ed i n ANSI / BHMA A156. 13 i s appl i ed t o t he l ever handl e. Pr ovi de l ever handl es r et ur n t o wi t hi n 1/ 2 i nch of t he door f ace.

2. 3. 8. 2 Text ur e

Pr ovi de knur l ed or abr asi ve coat ed knobs or l ever handl es f or door s whi ch ar e accessi bl e t o bl i nd per sons and whi ch l ead t o danger ous ar eas.

2. 3. 9 Keys

Pr ovi de one f i l e key, one dupl i cat e key, and one wor ki ng key f or each key change and f or each mast er and gr and mast er keyi ng syst em. Pr ovi de one addi t i onal wor ki ng key f or each l ock of each keyed- al i ke gr oup. Pr ovi de a mi ni mum of 3 keys per cor e. Pr ovi de a quant i t y of key bl anks equal t o 20 per cent of t he t ot al number of f i l e keys. St amp each key wi t h appr opr i at e key cont r ol symbol and " U. S. pr oper t y - do not dupl i cat e. " Do not pl ace r oom number on keys. Pr ovi de ext r a st ock of keys and cor es.

2. 3. 10 Door Bol t s

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 16. Pr ovi de dust pr oof st r i kes f or bot t om bol t s, except at door s havi ng met al t hr eshol ds. Pr ovi de aut omat i c l at chi ng f l ush bol t s i n accor dance wi t h ANSI / BHMA A156. 3, Type 25.

2. 3. 11 Cl oser s

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 4, Ser i es C02000, Gr ade 1, wi t h PT 4C. Pr ovi de wi t h br acket s, ar ms, mount i ng devi ces, f ast ener s, f ul l s i ze cover s, except at st or ef r ont mount i ng, pi vot s, and ot her f eat ur es necessar y f or t he par t i cul ar appl i cat i on. Si ze c l oser s i n accor dance wi t h manuf act ur er ' s pr i nt ed r ecommendat i ons, or pr ovi de mul t i - s i ze c l oser s, Si zes 1 t hr ough 6, and l i s t s i zes i n t he Har dwar e Schedul e. Pr ovi de manuf act ur er ' s 10 year war r ant y.

2. 3. 11. 1 I dent i f i cat i on Mar ki ng

Engr ave each cl oser wi t h manuf act ur er ' s name or t r ademar k, dat e of manuf act ur e, and manuf act ur er ' s s i ze desi gnat i on i n l ocat i ons t hat wi l l

SECTI ON 08 71 00 Page 8 be v i s i bl e af t er i nst al l at i on.

2. 3. 12 Over head Hol der s

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 8.

2. 3. 13 Door Pr ot ect i on Pl at es

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 6.

2. 3. 13. 1 Si zes of Ar mor and Ki ck Pl at es

2 i nch l ess t han door wi dt h f or s i ngl e door s; 1 i nch l ess t han door wi dt h f or pai r s of door s. Pr ovi de 10 i nch ki ck pl at es f or f l ush door s .

Pr ovi de a mi ni mum 36 i nch ar mor pl at es f or f l ush door s.

2. 3. 14 Door St ops and Si l encer s

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 16. Si l encer s Type L03011.

Pr ovi de t hr ee si l encer s f or each si ngl e door , t wo f or each pai r .

2.3.15 Padlocks

Provide BEST interchangeable cores that meet ASTM F883. Provide in accor-dance with ANSI/BHMA A156.30, security level ABC for all high security cylinder components. Mark "Property of U.S. Govt. "

2.3.16 Thresholds

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 21. Use J35100, wi t h v i nyl or s i l i cone r ubber i nser t i n f ace of st op, f or ext er i or door s openi ng out , unl ess speci f i ed ot her wi se.

2. 3. 17 Weat her st r i ppi ng Gasket i ng

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 22. Pr ovi de t he t ype and f unct i on desi gnat i on wher e speci f i ed i n par agr aph HARDWARE SCHEDULE.

Pr ovi de a set t o i ncl ude head and j amb seal s, sweep st r i ps, and, f or pai r s of door s, ast r agal s. Ai r l eakage of weat her st r i pped door s not t o exceed

1. 25 cubi c f eet per mi nut e of ai r per squar e f oot of door ar ea when t est ed i n accor dance wi t h ASTM E283. Pr ovi de weat her st r i ppi ng wi t h one of t he f ol l owi ng:

2. 3. 17. 1 Ext r uded Al umi num Ret ai ner s

Ext r uded al umi num r et ai ner s not l ess t han 0. 050 i nch wal l t hi ckness wi t h v i nyl , neopr ene, s i l i cone r ubber , or pol yur et hane i nser t s. Pr ovi de cl ear ( nat ur al ) anodi zed al umi num.

2. 3. 18 Soundpr oof i ng Gasket i ng

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 22. Pr ovi de adj ust abl e door st ops at heads, j ambs and aut omat i c door bot t oms i n accor dance wi t h t he har dwar e set , of ext r uded al umi num, c l ear ( nat ur al ) anodi zed, sur f ace appl i ed, wi t h v i nyl f i n seal s bet ween pl unger and housi ng. Pr ovi de door st ops wi t h sol i d neopr ene t ube, s i l i cone r ubber , or c l osed cel l sponge gasket . Pr ovi de door bot t oms wi t h adj ust abl e oper at i ng r od and si l i cone r ubber or c l osed cel l sponge neopr ene gasket . Pr ovi de door st ops t hat ar e mi t er ed at cor ner s. Pr ovi de t ype and f unct i on desi gnat i on wher e speci f i ed i n par agr aph HARDWARE SETS.

SECTI ON 08 71 00 Page 9

Addendum #1 - 08/21/2024

Eisner, Kelly Cloud

2. 3. 19 Rai n Dr i ps

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 22. Pr ovi de ext r uded al umi num r ai n dr i ps, not l ess t han 0. 08 i nch t hi ck, c l ear anodi zed f i ni sh. Pr ovi de t he manuf act ur er ' s f ul l r ange of col or choi ces t o t he Cont r act i ng Of f i cer f or col or sel ect i on Pr ovi de r ai n dr i ps wi t h a 4 i nch over l ap on each si de of each ext er i or door t hat i s not pr ot ect ed by an awni ng, r oof , eave or ot her hor i zont al pr oj ect i on. Set dr i ps i n seal ant and f ast en wi t h st ai nl ess st eel scr ews.

2. 3. 19. 1 Door Rai n Dr i ps

Appr oxi mat el y 1- 1/ 2 i nch hi gh by 5/ 8 i nch pr oj ect i on. Al i gn bot t om wi t h bot t om edge of door .

2. 3. 19. 2 Over head Rai n Dr i ps

Appr oxi mat el y 1- 1/ 2 i nch hi gh by 2- 1/ 2 i nch pr oj ect i on. Al i gn bot t om wi t h door f r ame r abbet .

2. 3. 20 Auxi l i ar y Har dwar e ( Ot her t han l ocks)

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 16, Gr ade 1.

2. 3. 21 Speci al Tool s

Pr ovi de speci al t ool s, such as spanner and socket wr enches and doggi ng keys, as r equi r ed t o ser vi ce and adj ust har dwar e i t ems.

2. 4 FASTENERS

Pr ovi de f ast ener s of t ype, qual i t y, s i ze, and quant i t y appr opr i at e t o t he speci f i c appl i cat i on. Fast ener f i ni sh t o mat ch har dwar e. Pr ovi de st ai nl ess st eel or nonf er r ous met al f ast ener s i n l ocat i ons exposed t o weat her . Ver i f y met al s i n cont act wi t h one anot her ar e compat i bl e and wi l l avoi d gal vani c cor r osi on when exposed t o weat her .

2. 5 FI NI SHES

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 18. Pr ovi de har dwar e i n BHMA 630 f i ni sh ( sat i n st ai nl ess st eel ) , unl ess speci f i ed ot her wi se. Pr ovi de i t ems not manuf act ur ed i n st ai nl ess st eel i n BHMA 626 f i ni sh ( sat i n chr omi um pl at ed) over br ass or br onze, except al umi num pai nt f i ni sh f or sur f ace door c l oser s, and except BHMA 652 f i ni sh ( sat i n chr omi um pl at ed) f or st eel hi nges. Pr ovi de hi nges f or ext er i or door s i n st ai nl ess st eel wi t h BHMA 630 f i ni sh or chr omi um pl at ed br ass or br onze wi t h BHMA 626 f i ni sh. Fur ni sh exi t devi ces i n BHMA 626 f i ni sh i n l i eu of BHMA 630 f i ni sh . Mat ch exposed par t s of conceal ed cl oser s t o l ock and door t r i m.

Mat ch har dwar e f i ni sh f or al umi num door s t o t he door s.

2. 6 KEY CABI NET AND CONTROL SYSTEM

Pr ovi de i n accor dance wi t h ANSI / BHMA A156. 5, Type r equi r ed t o y i el d a capaci t y ( number of hooks) 50 per cent gr eat er t han t he number of key changes used f or door l ocks.

SECTI ON 08 71 00 Page 10

2. 7 KEY BOXES

Pr ovi de Knox Box Company, " Remot e Power Box" wi t h t amper al er t . Box shal l be s i ngl e l ock r ecessed mount wi t h st ai nl ess st eel hi nged door and 9- 1/ 2" H x 9- 1/ 2" W f l ange. Pr ovi de uni t wi t h 5/ 8" t hi ck st eel door wi t h i nt er i or s i l i cone gasket seal and 1/ 4" pl at e st eel housi ng. Lock shal l have 1/ 8" dust cover wi t h t amper seal . Box and l ock shal l be UL l i s t ed. Lock shal l have doubl e act i on r ot at i ng t umbl er s and har dened st eel pi ns accessed by a bi ased cut key. Fi ni sh shal l be r ed. Pr ovi de ( 2) keys t o McEnt i r e Joi nt Nat i onal Guar d Base Fi r e Depar t ment St andar d.

At Sout h Bui l di ng Mai n Ent r y: Mount box secur el y wi t hi n f abr i cat ed wal l panel s mount ed at 4' - 0" AFF t o t he Bot t om of t he box as shown on t he ar chi t et ur al el evat i ons. Box i nst al l at i on shal l be f ul l y coor di nat ed wi t h t he el ect r i cal and secur i t y dr awi ngs.

PART 3 EXECUTI ON

3. 1 I NSTALLATI ON

Pr ovi de har dwar e i n accor dance wi t h manuf act ur er s ' pr i nt ed i nst al l at i on i nst r uct i ons. Fast en har dwar e t o wood sur f aces wi t h f ul l - t hr eaded wood scr ews or sheet met al scr ews. Pr ovi de machi ne scr ews set i n expansi on shi el ds f or f ast eni ng har dwar e t o sol i d concr et e and masonr y sur f aces.

Pr ovi de t oggl e bol t s wher e r equi r ed f or f ast eni ng t o hol l ow cor e const r uct i on. Pr ovi de t hr ough bol t s wher e necessar y f or sat i sf act or y i nst al l at i on.

3. 1. 1 Weat her st r i ppi ng I nst al l at i on

Pr ovi de f ul l cont act , weat her t i ght seal s t hat al l ow oper at i on of door s wi t hout bi ndi ng t he weat her st r i ppi ng.

3. 1. 1. 1 St op Appl i ed Weat her st r i ppi ng

Fast en i n pl ace wi t h col or mat ched sheet met al scr ews not mor e t han 9 i nch on cent er af t er door s and f r ames have been f i ni sh pai nt ed.

3. 1. 2 Soundpr oof i ng I nst al l at i on

Pr ovi de as speci f i ed f or st op appl i ed weat her st r i ppi ng.

3. 1. 3 Thr eshol d I nst al l at i on

Ext end t hr eshol ds t he f ul l wi dt h of t he openi ng and not ch end f or j amb st ops. Set t hr eshol ds i n a f ul l bed of seal ant and anchor t o f l oor wi t h cadmi um- pl at ed, count er sunk, st eel scr ews i n expansi on sl eeves.

3. 2 FI RE DOORS AND EXI T DOORS

Pr ovi de har dwar e i n accor dance wi t h NFPA 72 f or door al ar ms, NFPA 80 f or f i r e door s, NFPA 101 f or exi t door s, and NFPA 252 f or f i r e t est s of door assembl i es. .

3. 3 HARDWARE LOCATI ONS

Pr ovi de i n accor dance wi t h SDI / DOOR A250. 8, unl ess i ndi cat ed or speci f i ed ot her wi se.

SECTI ON 08 71 00 Page 11

a. Ki ck and Ar mor Pl at es: Push si de of s i ngl e- act i ng door s. Bot h s i des of doubl e- act i ng door s.

3. 4 KEY CABI NET AND CONTROL SYSTEM

Locat e wher e di r ect ed . Tag one set of f i l e keys and one set of dupl i cat e keys. Pl ace ot her keys i n appr opr i at el y mar ked envel opes, or t ag each key. Pr ovi de compl et e i nst r uct i ons f or set up and use of key cont r ol syst em. On t ags and envel opes, i ndi cat e door and r oom number s or mast er or gr and mast er key.

3. 5 FI ELD QUALI TY CONTROL

Af t er i nst al l at i on, pr ot ect har dwar e f r om pai nt , st ai ns, bl emi shes, and ot her damage unt i l accept ance of wor k. Submi t not i ce of t est i ng 15 days bef or e schedul ed, so t hat t est i ng can be wi t nessed by t he Cont r act i ng Of f i cer . Adj ust hi nges, l ocks, l at ches, bol t s, hol der s, c l oser s, and ot her i t ems t o oper at e pr oper l y. Demonst r at e t hat per manent keys oper at e r espect i ve l ocks, and gi ve keys t o t he Cont r act i ng Of f i cer . Cor r ect , r epai r , and f i ni sh, er r or s i n cut t i ng and f i t t i ng and damage t o adj oi ni ng wor k.

3. 6 HARDWARE SETS

SECTI ON 08 71 00 Page 12

Pr ovi de har dwar e f or al umi num door s under t hi s sect i on. Del i ver Har dwar e t empl at es and har dwar e, except f i el d appl i ed har dwar e, t o t he al umi num door and f r ame manuf act ur er f or use i n f abr i cat i ng door s and f r ames.

SET 1. 0 ( ACCESS CONTROL DOOR - SI NGLE EXTERI OR)

DOOR: 101A, 105A

1 CONTI NUOUS HI NGE

1 STOREROOM- FAI L SECURE LOCK, FUNCTI ON 07, MORTI SE LOCKSET, ELECTRI C LATCH

RETRACTI ON, FI XED EXTERI OR LEVER HANDLE, KEY OVERRI DE, FAI L SECURE,

( WI TH ESS I NTEGRATI ON)

1 PERMANENT CORE MATCH FACI LI TY KEYI NG

1 ELECTRI C TRANSFER DEVI CE

1 SURFACE CLOSER

1 KI CK PLATE

1 GASKETI NG/ WEATHER STRI PPI NG

1 SWEEP W/ HOOD

1 THRESHOLD

1 CARD READER / KEYPAD

1 POWER SUPPLY VOLTAGE X AMPERAGE AS REQ' D

OPERATI ON:

1. CARD READER / KEYPAD GRANTS ACCESS UPON PRESENTATI ON OF A VALI D

CREDENTI AL TO SI GNAL ELECTRI C LATCH RETRACTI ON.

2. LATCHBOLT RETRACTED BY KEY OUTSI DE OR BY OPERATI NG I NSI DE HANDLE ON

RESTRI CTED SI DE.

3. OUTSI DE LEVER I S ALWAYS I NOPERATI VE.

4. REQUEST SWI TCH I NSI DE HANDLE TO SI GNAL AUTHORI ZED EGRESS TO THE ACCESS

CONTROL SYSTEM. BALANCED MAGNETI C SWI TCH TO SI GNAL DOOR OPEN/ CLOSED TO

THE I NTRUSI ON DETECTI ON SYSTEM.

5. I NSI DE LEVER I S ALWAYS FREE FOR I MMEDI ATE EGRESS

SET 2. 0 ( ENTRANCE DOOR - SI NGLE I NTERI OR)

DOOR: 101B

3 HI NGE ( SI ZE PER SPEC, NRP AS APPLI CABLE)

1 EXI T DEVI CE, FUNCTI ON 10

1 PERMANENT CORE MATCH FACI LI TY KEYI NG

1 KEYED REMOVABLE MULLI ON

1 SURFACE CLOSER

1 GASKETI NG/ WEATHER STRI PPI NG

1 RAI N GUARD

1 SWEEP W/ HOOD

1 THRESHOLD

OPERATI ON:

1. ENTRANCE EXTERI OR LEVER. I NSI DE KEY LOCKS/ UNLOCKS EXTERI OR LEVER.

OUTSI DE KEY ONLY RETRACTS LATCH.

2. I NSI DE EXI T DEVI CE I S ALWAYS FREE FOR I MMEDI ATE EGRESS

3. I F THUMBTURN OR DEADBOLT I S ADDED, SI GNAGE MUST BE POSTED THAT READS

" THI S DOOR TO REMAI N UNLOCKED WHI LE BUI LDI NG I S OCCUPI ED, " AND BE

APPROVED BY LOCAL AHJ.

SET 3. 0 ( STOREROOM DOOR - SI NGLE EXTERI OR)

DOOR: 117A, 119A

3 HI NGE ( SI ZE PER SPEC, NRP AS APPLI CABLE)

1 STOREROOM, MORTI SE LOCKSET, FUNCTI ON 07, DEADLOCKI NG LATCH

SECTI ON 08 71 00 Page 13

1 PERMANENT CORE MATCH FACI LI TY KEYI NG

1 SURFACE CLOSER

1 WALL / FLOOR STOP

1 GASKETI NG SMOKE/ SOUND

OPERATI ON:

1. LATCHBOLT RETRACTED BY KEY OUTSI DE OR BY OPERATI NG I NSI DE LEVER.

2. OUTSI DE LEVER I S ALWAYS I NOPERATI VE.

3. I NSI DE LEVER I S ALWAYS FREE FOR I MMEDI ATE EGRESS.

SET 4. 0 ( STOREROOM DOOR - DOUBLE EXTERI OR)

DOOR: 106A, 113A

6 HI NGE ( SI ZE PER SPEC, NRP AS APPLI CABLE)

1 STOREROOM, MORTI SE LOCKSET, FUNCTI ON 07, DEADLOCKI NG LATCH ( ACTI VE LEAF)

1 PERMANENT CORE MATCH FACI LI TY KEYI NG

1 MORTI SE STI KE ( I NACTI VE LEAF)

1 ASTRAGAL

2 FLUSH BOLTS ( I NACTI VE LEAF)

2 SURFACE CLOSER

2 WALL / FLOOR STOP

2 GASKETI NG SMOKE/ SOUND

OPERATI ON:

1. LATCHBOLT RETRACTED BY KEY OUTSI DE OR BY OPERATI NG I NSI DE LEVER.

2. OUTSI DE LEVER I S ALWAYS I NOPERATI VE ACTI VE LEAF.

3. I NSI DE LEVER I S ALWAYS FREE FOR I MMEDI ATE EGRESS.

4. I NACTI VE LEAF I S HELD I N PLACE BY SURFACE MOUNTED FLUSH BOLTS TOP AND

BOTTOM AND CAN BE RETRACTED FROM I NSI DE FACE ONLY.

SET 5. 0 ( OFFI CE DOOR - SI NGLE I NTERI OR)

DOOR: 103A, 104A

3 HI NGE ( SI ZE PER SPEC, NRP AS APPLI CABLE)

1 OFFI CE, MORTI SE LOCKSET, FUNCTI ON 04

1 PERMANENT CORE MATCH FACI LI TY KEYI NG

1 SURFACE CLOSER

1 WALL / FLOOR STOP

1 GASKETI NG SMOKE/ SOUND

NOTES:

1. THRESHOLD, DOOR BOTTOM, AND SEALS PROVI DED BY STC DOOR MANUFACTURER

OPERATI ON:

1. LATCHBOLT RETRACTED BY LEVER FROM EI THER SI DE UNLESS OUTSI DE I S MADE

I NOPERATI VE BY KEY OUTSI DE OR I NSI DE PUSHBUTTON.

2. WHEN OUTSI DE I S LOCKED, THE LATCHBOLT I S RETRACTED BY KEY OUTSI DE OR BY

LEVER I NSI DE.

3. I NSI DE LEVER I S ALWAYS FREE FOR I MMEDI ATE EGRESS

SET 6. 0 ( STOREROOM DOOR - SI NGLE I NTERI OR)

DOOR: 107A, 115B

3 HI NGE ( SI ZE PER SPEC, NRP AS APPLI CABLE)

1 STOREROOM, MORTI SE LOCKSET, FUNCTI ON 07, DEADLOCKI NG LATCH

1 PERMANENT CORE MATCH FACI LI TY KEYI NG

1 SURFACE CLOSER

1 WALL / FLOOR STOP

1 GASKETI NG SMOKE/ SOUND

SECTI ON 08 71 00 Page 14

NOTES:

1. THRESHOLD, DOOR BOTTOM, AND SEALS PROVI DED BY STC DOOR MANUFACTURER

OPERATI ON:

1. LATCHBOLT RETRACTED BY KEY OUTSI DE OR BY OPERATI NG I NSI DE LEVER.

2. OUTSI DE LEVER I S ALWAYS I NOPERATI VE.

3. I NSI DE LEVER I S ALWAYS FREE FOR I MMEDI ATE EGRESS.

SET 7. 0 ( PUSH/ PULL DOOR - SI NGLE I NTERI OR)

DOOR: 108A, 112A

3 HI NGE ( SI ZE PER SPEC)

1 PULL PLATE

1 PUSH PLACE

1 SURFACE CLOSER

1 KI CK PLATE

1 WALL / FLOOR STOP

1 GASKETI NG SMOKE/ SOUND

OPERATI ON:

1. NO LATCHI NG I S REQUI RED. PUSH / PULL PLATE.

SET 8. 0 ( ACCESS CONTROL DOOR - SI NGLE I NTERI OR)

DOOR: 114A, 115A, 116A, 118A, 120A, 121A, 122A, 123A, 125A, 126A, 127A,

128A, 130A, 131A, 132A, 133A, 134A, 135A

1 CONTI NUOUS HI NGE

1 STOREROOM- FAI L SECURE LOCK, FUNCTI ON 07, MORTI SE LOCKSET, ELECTRI C LATCH

RETRACTI ON, FI XED EXTERI OR LEVER HANDLE, KEY OVERRI DE, FAI L SECURE,

( WI TH ESS I NTEGRATI ON)

1 PERMANENT CORE MATCH FACI LI TY KEYI NG

1 ELECTRI C TRANSFER DEVI CE

1 SURFACE CLOSER

1 KI CK PLATE

1 GASKETI NG SMOKE/ SOUND

1 CARD READER / KEYPAD

1 POWER SUPPLY VOLTAGE X AMPERAGE AS REQ' D

NOTES:

1. THRESHOLD, DOOR BOTTOM, AND SEALS PROVI DED BY STC DOOR MANUFACTURER

OPERATI ON:

1. CARD READER / KEYPAD GRANTS ACCESS UPON PRESENTATI ON OF A VALI D

CREDENTI AL TO SI GNAL ELECTRI C LATCH RETRACTI ON.

2. LATCHBOLT RETRACTED BY KEY OUTSI DE OR BY OPERATI NG I NSI DE HANDLE ON

RESTRI CTED SI DE.

3. OUTSI DE LEVER I S ALWAYS I NOPERATI VE.

4. REQUEST SWI TCH I NSI DE HANDLE TO SI GNAL AUTHORI ZED EGRESS TO THE ACCESS

CONTROL SYSTEM. BALANCED MAGNETI C SWI TCH TO SI GNAL DOOR OPEN/ CLOSED TO

THE I NTRUSI ON DETECTI ON SYSTEM.

5. I NSI DE LEVER I S ALWAYS FREE FOR I MMEDI ATE EGRESS

SET 9. 0 ( ACCESS CONTROL DOOR - DOUBLE I NTERI OR)

DOOR: 124A, 129A

2 CONTI NUOUS HI NGE

1 EXI T DEVI CE, MORTI SE LOCKSET, ELECTRI C LATCH RETRACTI ON, FI XED EXTERI OR

LEVER HANDLE, KEY OVERRI DE, FAI L SECURE, ( WI TH ESS I NTEGRATI ON)

SECTI ON 08 71 00 Page 15

1 PERMANENT CORE MATCH FACI LI TY KEYI NG

2 ELECTRI C TRANSFER DEVI CE

2 SURFACE CLOSER

1 ASTRAGAL

2 FLUSH BOLTS ( I NACTI VE LEAF)

2 KI CK PLATE

2 GASKETI NG/ WEATHER STRI PPI NG

2 RAI N GUARD

2 SWEEP W/ HOOD

1 THRESHOLD

1 CARD READER / KEYPAD

1 POWER SUPPLY VOLTAGE X AMPERAGE AS REQ' D

NOTES:

1. THRESHOLD, DOOR BOTTOM, AND SEALS PROVI DED BY STC DOOR MANUFACTURER

OPERATI ON:

1. CARD READER / KEYPAD GRANTS ACCESS UPON PRESENTATI ON OF A VALI D

CREDENTI AL TO SI GNAL ELECTRI C LATCH RETRACTI ON.

2. LATCHBOLT RETRACTED BY KEY OUTSI DE OR BY OPERATI NG I NSI DE HANDLE ON

RESTRI CTED SI DE.

3. OUTSI DE LEVER I S ALWAYS I NOPERATI VE.

4. REQUEST SWI TCH I NSI DE HANDLE TO SI GNAL AUTHORI ZED EGRESS TO THE ACCESS

CONTROL SYSTEM. BALANCED MAGNETI C SWI TCH TO SI GNAL DOOR OPEN/ CLOSED TO

THE I NTRUSI ON DETECTI ON SYSTEM.

5. I NSI DE EXI T DEVI CE I S ALWAYS FREE FOR I MMEDI ATE EGRESS

SET 10. 0 ( HI GH SECURI TY PRI MARY DOOR - SI NGLE I NTERI OR )

DOOR: 109A

1 CONTI NUOUS HI NGE

1 ELECTRI C POWER TRANSFER

1 PEDESTRI AN DEADBOLT DEVI CE ( WI TH STRI KE AND MOUNTI NG ASSEMBLI ES)

COMPLYI NG WI TH FF- L- 2740B.

1 TYPE I V EXI T DEVI CE - I NTEGRATED ACCESS CONTROL

COMPLYI NG WI TH FF- L- 2890C WI TH REQUEST TO EXI T SWI TCH AND KEY OVERRI DE

1 SURFACE CLOSER

1 KI CK PLATE

1 GASKETI NG SMOKE/ SOUND

1 THRESHOLD

1 CARD READER / KEYPAD

1 POWER SUPPLY VOLTAGE X AMPERAGE AS REQ' D

1 HI GH SECURI TY SWI TCH, LEVER 2, UL634 SURFACE MOUNTED

NOTES:

1. THRESHOLD, DOOR BOTTOM, AND SEALS PROVI DED BY STC DOOR MANUFACTURER

OPERATI ON:

1. PEDESTRI AN DEADBOLT DEVI CE ( X- 10 COMBI NATI ON LOCK) I S THE FI RST TI ER OF

SECURI TY AND MUST BE UNLOCKED. I N ORDER FOR THE SECOND TI ER ( CARD

READER) TO BECOME OPERATI ONAL.

2. CARD READER GRANTS ACCESS UPON PRESENTATI ON OF A VALI D CREDENTI AL. LOCK

TO FAI L SECURE DURI NG POWER FAI LURE.

3. EGRESS ALWAYS FREE FROM I NSI DE BY I NSI DE EXI T DEVI CE.

4. REQUEST SWI TCH I NSI DE EXI T DEVI CE TO SI GNAL AUTHORI ZED EGRESS TO THE

ACCESS CONTROL SYSTEM.

5. HI GH SECURI TY SWI TCH TO SI GNAL DOOR OPEN/ CLOSED TO THE I NTRUSI ON

DETECTI ON SYSTEM.

SECTI ON 08 71 00 Page 16

SET 12 ( HI GH SECURI TY EXI T ONLY DOOR - SI NGLE I NTERI OR)

DOOR: 127B

1 CONTI NUOUS HI NGE

1 TYPE X EXI T DEVI CE - COMPLYI NG WI TH FF- L- 2890C.

1 LOCAL AUDI BLE ALARM I NTEGRATI ON WI TH HI GH SECURI TY SWI TCH

1 SURFACE CLOSER

1 KI CK PLATE

1 GASKETI NG/ WEATHER STRI PPI NG

1 RAI N GUARD

1 SWEEP W/ HOOD

1 THRESHOLD

1 HI GH SECURI TY SWI TCH, LEVER 2, UL634 SURFACE MOUNTED

NOTES:

1. THRESHOLD, DOOR BOTTOM, AND SEALS PROVI DED BY STC DOOR MANUFACTURER.

2. DOUBLE POLE DOUBLE THROUGH HI GH SECURI TY SWI TCH TO SI GNAL DOOR

OPEN/ CLOSED TO THE I NTRUSI ON DETECTI ON SYSTEM AND SI GNAL LOCAL AUDI BLE

ALARM.

SET 13 ( HI GH SECURI TY FI XED DOOR - DOUBLE EXTERI OR)

DOOR: 122B, 123B, 129B, 134B, 135B

2 CONTI NUOUS HI NGE

1 LOCAL AUDI BLE ALARM I NTEGRATI ON WI TH HI GH SECURI TY SWI TCH

1 ASTRAGAL

4 FLUSH BOLTS

2 KI CK PLATE

1 GASKETI NG/ WEATHER STRI PPI NG

1 SWEEP W/ HOOD

1 THRESHOLD

2 HI GH SECURI TY SWI TCH, LEVER 2, UL634 SURFACE MOUNTED

NOTES:

1. NEW STC DOOR - FOR THE I NSTALLATI ON OF CPT EQUI PMENT, DOOR LEAFS TO BE

FI XED FROM THE I NTERI OR SI DE AFTER I NSTALLATI ON OF CPT.

2. DOUBLE POLE DOUBLE THROUGH HI GH SECURI TY SWI TCH TO SI GNAL DOOR

OPEN/ CLOSED TO THE I NTRUSI ON DETECTI ON SYSTEM AND SI GNAL LOCAL AUDI BLE

ALARM.

- - End of Sect i on - -

SECTI ON 08 71 00 Page 17

File details come from the government source that posted it. Updated .