AE305-WALL SECTIONS.pdf
PDF 281 KB Posted
- Attached to
- Construct Mission Training Center (MTC) Facility Federal contract opportunity
- Solicitation number
- W50S78-24-B-0001
- Issued by
- Department of the Army National Guard
About this file
This document appears to be the wall sections for a federal construction project. The key details are:
The federal contract opportunity is for the construction of a 15,200 square foot Mission Training Center (MTC) facility for the Texas Air National Guard at Joint Base San Antonio Lackland Air Force Base. The contract will be a single firm fixed-price contract with a duration of 540 calendar days. The project includes demolition, site work, utilities, masonry, roofing, structural steel, HVAC, plumbing, electrical, communications, fire protection, and other related work. In addition to a base bid, there are 8 options including items such as permeable pavement, landscaping, floor coatings, wall/floor tile, additional drains, insignia signage, and fixed seating. The project is set aside 100% for Small Business under NAICS code 236220. A site visit and pre-bid conference are scheduled in August 2024, and the solicitation will be issued through SAM.gov. The government has identified 5 brand name items required for compatibility with existing systems.
View the file
Other files for this federal contract opportunity
Show all 50
Construct Mission Training Center (MTC) Facility has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GROUND FLOOR
100' - 0"
LOW EAVE (LOW) DB
115' - 0"
F
C3
AE502
(SSSR1) STEEL
STANDING SEAM
ROOFING
FALL PROTECTION
SYSTEM
4 LAYERS 2" RIGID
INSULATION
1/2" COVERBOARD
STEEL DECK
LIGHT FIXTURE
(FWP2) 2" INSULATED
METAL WALL PANEL
FLUID APPLIED
MEMBRANE AIR
BARRIER
1/2" EXT GYPSUM
SHEATHING
6" CFMF AT 16" OC
6" CFMF AT 16" OC
STEEL STRUCTURE
NOM 4" SPRAY FOAM AIR
BARRIER - OPEN CELL (R-17 MIN.)
WITH ASTM E84 COMPLIANT FIRE
RETARDANT SURFACE FILM
CONT 1/2" EXT
GYPSUM SHEATHING
CLOSURE
1" / 1'-0"
BID OPTION:
ILLUMINATED INSIGNIA
SIGNAGE - O.L.I. #7
(FWP2) 2" INSULATED
METAL WALL PANEL
PREFIN BRAKE METAL
SILL FLASHING
(MV1) MODULAR
BRICK VENEER
CONCRETE PAVING CONCRETE SLAB
STOREFRONT
GLAZING SYSTEM
EX1
SCHEDULED CEILING
A3
VEST
CORRIDOR
25' - 0"
A1
AE502
EX1FIRE ALARM CONTROL
UNIT
RUBBER BASE RB1
SECURITY CAMERA
PREFINISHED METAL
GUTTER AND
DOWNSPOUT
1" / 1'-0"
2 LAYERS OF 5/8” GYSUM
WALL BOARD (GWB) WITH
PERFORATED RF
SHIELDING/ FOIL MEMBRANE
ADHERED BETWEEN
LAYERS
16 GA 3" HORIZ Z-
CHANNEL AT 48"
VERTICALLY
GROUND FLOOR
100' - 0"
LOW EAVE (LOW) DB
115' - 0"
F E
A1
AE103
A3
AE502
8' -8
6'
-4
(SSSR1) STEEL
STANDING SEAM
ROOFING
METAL SOFFIT
FALL PROTECTION
SYSTEM
PREFINISHED METAL
GUTTER AND
DOWNSPOUT
STEEL STRUCTURE
(FWP1) 2" INSULATED
METAL WALL PANEL
FLUID APPLIED
MEMBRANE AIR
BARRIER
1/2" EXT GYPSUM
SHEATHING
STORAGE
MEN
STEEL DECK
6" CFMF AT 16" OC
(FWP1) 2" INSULATED
METAL WALL PANEL
FLUID APPLIED
MEMBRANE AIR BARRIER
1/2" EXT GYPSUM
SHEATHING
NOM 4" SPRAY FOAM AIR
BARRIER - OPEN CELL
(R-17 MIN.) WITH ASTM E84
COMPLIANT FIRE
RETARDANT SURFACE FILM
6" CFMF AT 16" OC
ROWLOCK COURSE
(MV1) MODULAR BRICK
VENEER
2" CAVITY WALL
INSULATION BOARD
CONCRETE
FOUNDATION
CONCRETE SLAB
ROOF HATCH
SAFETY
LANYARD
ROOF ACCESS
LADDER
A2
C4
AE501
A3
AE501
16 GA 3" HORIZ Z-
CHANNEL AT 48"
VERTICALLY
OH
GROUND FLOOR
100' - 0"
STEEL STRUCTURE
CONCRETE SLAB
(SSSR1) STEEL
STANDING SEAM
ROOFING
SCHEDULED
CEILING
MAN TRAP
CORRIDOR
C3
AE503
2 LAYERS OF 5/8"
GYPSUM WALL BOARD
SIM
PERFORATED RF SHIELDING/
FOIL MEMBRANE ADHERED
BETWEEN GWB LAYERS
REFER AE520 FOR TYPICAL
RF SHIELDING/FOIL NOTES
AND DETAILS
5/8” GYSUM WALL BOARD
(GWB) 2 LAYERS
S3f
GROUND FLOOR
100' - 0"
F E
6"6" 3'
-0
6"6" 2'
-0
1' -0
6"
6"
6" 6"
4'-0" 1'-0"
TIERED ACCESS
FLOOR SYSTEM
AND SUPPORTS
PROPOSED FIXED
SEATING WITH
TABLET ARMS -
O.L.I. #8
6'-0" 1'-0"
6'-0" 1'-0"
6'-0" 1'-0"
3' -0
3' -0
3' -0
3' -0
3' -0
1.9" OD STEEL PIPE
HANDRAIL AND WALL
MOUNT BRACKETS
1'-0" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0" 1'-0"
WOOD BLOCKING
BACK-UP - TYP.
AE305
D2
1.9"OD DIA
STEEL PIPE
HANDRAIL AND
WALL
BRACKES
FACE OF FINISH WALL
ESCUTCHEON
COVER PLATE
1 1/2"
MIN
WOOD
BLOCKING
BACKING - TYP.
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
Frankfurt-Short-Bruza Associates,P.C.
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
C
B
A
D
C
B
A
54321
20190310
NDM
Jo int
B as e S an
A nto nio
JB
SA
Ke lly
A nn ex , T ex as
Te xa s A ir
Na tio na l G ua rd
9t h
FW
F-1
6 M iss ion Tr ain ing
C en ter (M
TC
C :\U sers\keisner\D ocum ents\90310_Arch_keisnerU
7YM
G .rvt
9/16/2024 10:21:24 AM
15 AUGUST 2024
WALL SECTIONS
AE305
MJT
BKG
GMD
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
Frankfurt-Short-Bruza Associates,P.C.
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
C
B
A
D
C
B
A
54321
20190310
NDM
Jo int
B as e S an
A nto nio
JB
SA
Ke lly
A nn ex , T ex as
Te xa s A ir
Na tio na l G ua rd
9t h
FW
F-1
6 M iss ion Tr ain ing
C en ter (M
TC
0 1' 2' 4'
1/2" = 1'-0"
C :\U sers\keisner\D ocum ents\90310_Arch_keisnerU
7YM
G .rvt
9/16/2024 10:21:25 AM
15 AUGUST 2024
WALL SECTIONS
AE305
MJT
BKG
GMD
LEGEND GRAPHIC VISUAL PLANE OF CONT AIR
BARRIER WHERE SHOWN ALL SHEETS
SCALE: 1/2" = 1'-0"
WALL SECTION @ ENTRY VESTA1 SCALE: 1/2" = 1'-0"
WALL SECTIONA4SCALE: 1/2" = 1'-0"
WALL SECTIONA3
SCALE: 3/4" = 1'-0"
SECTION DETAIL - CLASSROOM 114 AND MOC 121 - TYP RAISED FLOORING AND SEATINGC3
SCALE: 3" = 1'-0"
HANDRAIL DETAILD2
NOTE: REFERENCE SPECIFICATION SECTIONS
07 05 23 AND 07 27 10.00 10 FOR DESCRIPTION
OF AIR BARRIER SYSTEM
1' 3'2'0
3/4" = 1'-0"
3" 9"6"0
3" = 1'-0"
AREA 1 - GENERAL NOTES
1 Addendum 02 09/16/20241 Addendum 02 09/16/2024
1. APPLY MINIMUM 2” WIDE FOIL TAPE CENTERED
OVER ALL EXPOSED BED AND HEAD JOINTS NO
DRYWALL COMPOUND (LAP 1/2” DOWN HORIZONTALLY
ONTO FLOOR SLAB AND GENEROUSLY LAP AT THE
HEAD OF THE WALL PER DETAIL CONDITION)
2. APPLY MINIMUM 2” WIDE FOIL TAPE CENTERED
OVER ALL VERTICAL FASTENERS HEADS.
3. APPLY MINIMUM 12” WIDE FOIL TAPE CENTERED ON
EACH CORNER INTERSECTION. (6” LAP EACH WAY)
REFER TO SHEET AE002 FOR "AREA 1" PERIMETER
WALL. REFER TO SHEET AE520 FOR TYPICAL RF
SHIELDING/FOIL MEMBRANE NOTES AND DETAILS.