About this file
This document contains detailed design drawings and specifications for the construction of a Mission Training Center (MTC) facility for the Texas Air National Guard at Joint Base San Antonio Lackland Air Force Base.
The key details are: The government is soliciting bids for a firm fixed-price contract to construct a 15,200 square foot FTU 4-ship F-16 MTC facility, including demolition, site work, utilities, HVAC, plumbing, electrical, and other work. The contract duration will be 540 calendar days. The solicitation includes a base bid as well as 8 specified options. Certain brand name items are required for compatibility with existing systems. This 100% small business set-aside project has a NAICS code of 236220 and an estimated value between $10-25 million. A site visit and pre-bid conference are scheduled in August 2024, and all questions/RFIs must be submitted 5 days prior to bid opening. The government will only distribute amendments electronically through the SAM.gov website.
View the file
Other files for this federal contract opportunity
Show all 50
Construct Mission Training Center (MTC) Facility has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1/2" HORIZ
RESILIENT
CHANNELS AT 24"
OC VERTICALLY
5/8" GWB
6" CFMF AT 16" OC
1/2" EXT GYPSUM
SHEATHING
2" RIGID INSULATION
PREFINISHED METAL
FLASHING
MASONRY VENEER
FLUID APPLIED AIR &
WATER BARRIER
STEEL LINTEL ANGLE,
PAINT TO MATCH
MASONRY VENEER
NOM 4" SPRAY
FOAM AIR
BARRIER
STEEL FRAME
CONT SEALANT
(BOTH SIDES)
SCHEDULED DOOR
107'-4"
TOP OF FRAME
MORTAR CONTROL
MESH
WEEPS
SEALANT
1 1/8"6"2"
5/8" 1/2"
6"1/2"2"3 1/2"3 5/8"
1/2" HORIZ
RESILIENT
CHANNELS AT 24"
OC VERTICALLY
5/8" GWB
6" CFMF AT 16" OC
1/2" EXT GYPSUM
SHEATHING
2" RIGID
INSULATION
MASONRY
ANCHORS
MASONRY
VENEER
NOM 4" SPRAY
FOAM AIR BARRIER
FLUID APPLIED AIR
& WATER BARRIER
STEEL FRAME
CONT SEALANT
(BOTH SIDES)
SCHEDULED DOOR
DOUBLE JAMB STUDS
(CLIP AT 12" OC VERT)
3 5/8" 3 1/2" 2" 1/2" 6" 1/2"
5/8"
7 5/8" 2" 6" 1 1/8"
1/2" RESILIENT
CHANNEL AT 24"
OC
5/8" GWB
6" CFMF AT 16" OC
1/2" EXT GYPSUM
SHEATHING
2" RIGID INSULATION
PREFINISHED METAL
FLASHING WITH DRIP
EDGE
MASONRY VENEER
FLUID APPLIED
VAPOR BARRIER
8x6x7/16" STEEL
LINTEL ANGLE -
PAINT TO MATCH
MASONRY VENEER
108'-8"
TOP OF FRAME
NOM 4" SPRAY
FOAM AIR BARRIER
STC-50 RATED
DOOR AND FRAME
ASSEMBLY
(107'-04" AT DR 125A)
MORTAR
CONTROL MESH
WEEPS
FILL SOLID W/ SOUND
DEADENING GROUT
MATERIAL
1/2" HORIZ RESILIENT
CHANNELS AT 24" OC
VERTICALLY
5/8" GWB
6" CFMF AT 16" OC
1/2" EXT
GYPSUM
SHEATHING
2" RIGID INSULATION
MASONRY
ANCHORS
MASONRY
VENEER
NOM 4" SPRAY FOAM
AIR BARRIER
FLUID APPLIED AIR &
WATER BARRIER
DOUBLE JAMB STUDS
(CLIP AT 12" OC VERT)
STC-50 RATED
PARTITION PER
PLAN
STC-50 RATED
DOOR AND FRAME
ASSEMBLY
FILL SOLID W/ SOUND
DEADENING GROUT
MATERIAL
CONT SEALANT
BOTH SIDES
1/2" HORIZ RESILIENT
CHANNELS AT 24" OC
VERTICALLY
5/8" GWB
6" CFMF AT 16" OC
1/2" EXT GYPSUM
SHEATHING
NOM 4" SPRAY FOAM
AIR BARRIER
FLUID APPLIED AIR &
WATER BARRIER
DOUBLE JAMB STUDS
(CLIP AT 12" OC VERT)
STC-50 RATED
PARTITION
PER PLAN
STC-50 RATED
DOOR AND FRAME
ASSEMBLY
FILL SOLID W/ SOUND
DEADENING GROUT
MATERIAL
1/2" PLYWOOD
FWP1 2" INSULATED
METAL WALL PANEL
NOM 4" SPRAY FOAM
AIR BARRIER
3" 16 GA HORIZ FURRING
CHANNEL AT 48" OC
VERTICALLY
1/2" RESILIENT
CHANNEL AT 24" OC
5/8" GWB
6" CFMF AT 16" OC
1/2" EXT GYPSUM
SHEATHING
PREFINISHED METAL
FLASHING WITH DRIP
EDGE
FLUID APPLIED
VAPOR BARRIER
108'-8"
TOP OF FRAME
NOM 4" SPRAY FOAM
AIR BARRIER
STC-50 RATED DOOR
AND FRAME
ASSEMBLY
PRE-FINISHED
EXTRUSION W/WEEP
HOLES
FWP1 2" INSULATED
METAL WALL PANEL
1/2" EXT GYPSUM
SHEATHING
1/2" PLYWOOD
CONT SEALANT
(BOTH SIDES)
FILL SOLID W/ SOUND
DEADENING GROUT
MATERIAL
3"
16 GA 3" HORIZ Z-
CHANNEL AT 48"
VERTICALLY
1/2" HORIZ
RESILIENT
CHANNELS AT 24"
OC VERTICALLY
5/8" GWB
6" CFMF AT 16" OC
1/2" EXT GYPSUM
SHEATHING
NOM 4" SPRAY
FOAM AIR BARRIER
FLUID APPLIED AIR
& WATER BARRIER
STEEL FRAME
CONT SEALANT
(BOTH SIDES)
SCHEDULED DOOR
DOUBLE JAMB STUDS
(CLIP AT 12" OC VERT)
FWP1 2" INSULATED
METAL WALL PANEL
1/2" PLYWOOD
SEALANT
2" 6" 1 1/8"
1/2" HORIZ
RESILIENT
CHANNELS AT 24"
OC VERTICALLY
5/8" GWB
6" CFMF AT 16" OC
1/2" EXT GYPSUM
SHEATHING
FWP1 2" INSULATED
METAL WALL PANEL
PRE-FINISHED
EXTRUSION W/WEEP
HOLES
FLUID APPLIED AIR &
WATER BARRIER
PRE-FINISHED METAL
FLASHING WITH DRIP
EDGE
NOM 4" SPRAY FOAM
AIR BARRIER
STEEL FRAME
CONT SEALANT
(BOTH SIDES)
SCHEDULED
DOOR
107'-4"
TOP OF FRAME
SEALANT
2" 3"
1/2" 6"
1/2" 5/8"
11 1/2" 8 3/8"
1 1/8"6"2"
1/2" HORIZ RESILIENT
CHANNELS AT 24" OC
VERTICALLY
5/8" GWB
6" CFMF AT 16" OC
1/2" EXT GYPSUM
SHEATHING
NOM 4" SPRAY FOAM
AIR BARRIER DOUBLE JAMB STUDS
(CLIP AT 12" OC VERT)
STC-50 RATED
DOOR AND FRAME
ASSEMBLY
FILL SOLID W/ SOUND
DEADENING GOUT
MATERIAL
1/2" PLYWOOD
FWP1 2" INSULATED
METAL WALL PANEL
3" 16 GA HORIZ FURRING
CHANNEL AT 48" OC
VERTICALLY
2" RIGID INSULATION
MASONRY
ANCHORS
MASONRY
VENEER
FLUID APPLIED AIR &
WATER BARRIER
STEEL STRUCTURE
FOR FUTURE DOOR
REPLACEMENT.
SEALANT
SEALANT
SEALANT
1/2" HORIZ RESILIENT
CHANNELS AT 24" OC
VERTICALLY
5/8" GWB
6" CFMF AT 16" OC
1/2" EXT GYPSUM
SHEATHING
NOM 4" SPRAY FOAM
AIR BARRIER
DOUBLE JAMB STUDS
(CLIP AT 12" OC VERT)
STC-50 RATED
DOOR AND FRAME
ASSEMBLY
FILL SOLID W/ SOUND
DEADENING GROUT
MATERIAL
1/2" PLYWOOD
FWP1 2" INSULATED
METAL WALL PANEL
3" 16 GA HORIZ FURRING
CHANNEL AT 48" OC
VERTICALLY
FLUID APPLIED AIR &
WATER BARRIER STEEL STRUCTURE
FOR FUTURE DOOR
REPLACEMENT.
METAL WALL PANEL
CONTROL JOINT.
ALIGN WITH EDGE OF
STEEL STRUCTURE.
5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436
405.840.2931 | fsb-ae.com
Frankfurt-Short-Bruza Associates,P.C.
D
SHEET NUMBER:
ISSUE DATE:
SHEET TITLE:
PROJECT NUMBER:
PROJECT INFORMATION:
REVISION HISTORY:
DATEDESCRIPTION
REVIEWED BY:
DRAWN BY:
DESIGNED BY:
PROJECT MANAGER:
C
B
A
D
C
B
A
54321
20190310
NDM
Jo int
B as e S an
A nto nio
JB
SA
Ke lly
A nn ex , T ex as
Te xa s A ir
Na tio na l G ua rd
9t h
FW
F-1
6 M iss ion Tr ain ing
C en ter (M
TC
3" 9"6"0
3" = 1'-0"
C :\U sers\keisner\D ocum ents\90310_Arch_keisnerU
7YM
G .rvt
9/16/2024 10:33:41 AM
15 AUGUST 2024
DOOR DETAILS
AE603
MJT
BKG
GMD
SCALE: 3" = 1'-0"
HEAD DETAIL @ BRICKA4
SCALE: 3" = 1'-0"
JAMB DETAIL @ BRICKB4
SCALE: 3" = 1'-0"
HEAD DETAIL @ BRICKC4
SCALE: 3" = 1'-0"
JAMB DETAIL @ BRICKD4
LEGEND GRAPHIC VISUAL PLANE OF CONT AIR
BARRIER WHERE SHOWN ALL SHEETS
SCALE: 3" = 1'-0"
JAMB DETAIL @ WALL PANELD3
SCALE: 3" = 1'-0"
HEAD DETAIL @ WALL PANELC3
SCALE: 3" = 1'-0"
JAMB DETAIL @ WALL PANELB3
SCALE: 3" = 1'-0"
HEAD DETAIL @ WALL PANELA3SCALE: 3" = 1'-0"
PLAN DETAIL AT STC 50 DOORA1
SCALE: 3" = 1'-0"
PLAN DETAIL AT STC 50 DOORB1
NOTE: REFERENCE SPECIFICATION SECTIONS
07 05 23 AND 07 27 10.00 10 FOR DESCRIPTION
OF AIR BARRIER SYSTEM
1 Addendum 02 09/16/2024