AE603-DOOR DETAILS.pdf

PDF 296 KB Posted

Attached to
Construct Mission Training Center (MTC) Facility Federal contract opportunity
Solicitation number
W50S78-24-B-0001
Issued by
Department of the Army National Guard

About this file

This document contains detailed design drawings and specifications for the construction of a Mission Training Center (MTC) facility for the Texas Air National Guard at Joint Base San Antonio Lackland Air Force Base.

The key details are: The government is soliciting bids for a firm fixed-price contract to construct a 15,200 square foot FTU 4-ship F-16 MTC facility, including demolition, site work, utilities, HVAC, plumbing, electrical, and other work. The contract duration will be 540 calendar days. The solicitation includes a base bid as well as 8 specified options. Certain brand name items are required for compatibility with existing systems. This 100% small business set-aside project has a NAICS code of 236220 and an estimated value between $10-25 million. A site visit and pre-bid conference are scheduled in August 2024, and all questions/RFIs must be submitted 5 days prior to bid opening. The government will only distribute amendments electronically through the SAM.gov website.

View the file

Other files for this federal contract opportunity

Other files attached to Construct Mission Training Center (MTC) Facility, newest first.
File Type Posted
C-301-REMOVAL PLAN.pdf PDF
S-002-TYPICAL DETAILS.pdf PDF
SF101-LOW ROOF FRAMING PLAN.pdf PDF
S-001-GENERAL NOTES.pdf PDF
New Utilities to East.pdf PDF
M-501 DETAILS.pdf PDF
AE501-SECTION DETAILS.pdf PDF
AE305-WALL SECTIONS.pdf PDF
C-201-STORMWATER POLLUTION PREVENTION PLAN.pdf PDF
C-601-UTILITY PLAN.pdf PDF
SF102-HIGH ROOF FRAMING PLAN.pdf PDF
G-003-CODE AND LIFE SAFETY PLAN.pdf PDF
M-702 SCHEDULES.pdf PDF
M-701 SCHEDULES.pdf PDF
AE601-ROOM FINISH SCHEDULE AND GLAZING TYPES AND MISC DETAILS.pdf PDF
AE303-WALL SECTIONS.pdf PDF
23 05 48.19 - SEISMIC BRACING FOR HVAC.pdf PDF
23 05 48.00 40 - VIBRATION CONTROLS FOR HAC PIPING AND EQUIPMENT.pdf PDF
11 94 10 - Rooftop Fall Protection Anchors.pdf PDF
000 TABLE OF CONTENTS.pdf PDF
01 45 35 - Special Inspections.pdf PDF
C-401-PROPOSED PLAN.pdf PDF
C-602-DRAINAGE SCHEDULE AND DETAILS.pdf PDF
ES101-ELECTRICAL SITE PLAN.pdf PDF
AE401-ENLARGED PLANS AND DETAILS.pdf PDF
AE503-SECTION DETAILS.pdf PDF
01 45 00 - Quality Control.pdf PDF
W50S78-24-B-0001 - Mission Training Center Amendment 0003.pdf PDF
Attachment 14 - Geotechnical report-TX ANG Mission Training Center B-3.pdf PDF
MTC RFI log.pdf PDF
W50S7824B0001 - MTC - Amendment 02 - 20240829.pdf PDF
MFR Mission Training Center - 2nd Site Visit Pre-Propsal Conference Minutes.pdf PDF
Pre_Bid_Site Visit_MTC_Attendance_Sheet 27_Aug _2024.pdf PDF
Pre-Proposal Site Visit Slides - MTC 27 Aug 24.pptx PPTX presentation
2024.08.21_TX-ANG_149TH MISSION TRAINING CENTER_REVISED B3_VOL 1 SPECIFICATIONS.pdf PDF
ATTACHMENT 9 SPECS V1 ADDENDUM.pdf PDF
MTC RFI log.pdf PDF
Pre-Proposal Site Visit Slides - MTC 20 Aug 24 (002).pptx PPTX presentation
Pre_Bid_Site Visit_MTC_Attendance_Sheet 20_Aug _2024.pdf PDF
Attachment 6_Industrial Security.pdf PDF
Attachment 7_ACCESS AND STAGING SITE PLAN.pdf PDF
Attachment 5_STRUCTURAL INTERIOR DESIGN.pdf PDF
JA Nm Brand DDC Redacted.pdf PDF
JA Nm Brand Falcon Redacted.pdf PDF
W50S78-24-B-0001 - Mission Training Center Solicitation.pdf PDF
2024.08.15_TX-ANG_149TH MISSION TRAINING CENTER_REVISED B3_DRAWINGS.pdf PDF
JA Nm Brand Monaco Redacted.pdf PDF
JA Nm Brand Trane HVAC Redacted.pdf PDF
2024.08.15_TX-ANG_149TH MISSION TRAINING CENTER_REVISED B3_VOL 1 SPECIFICATIONS.pdf PDF
JA Nm Brand Vindicator Sys Redacted.pdf PDF
Show all 50

Construct Mission Training Center (MTC) Facility has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1/2" HORIZ

RESILIENT

CHANNELS AT 24"

OC VERTICALLY

5/8" GWB

6" CFMF AT 16" OC

1/2" EXT GYPSUM

SHEATHING

2" RIGID INSULATION

PREFINISHED METAL

FLASHING

MASONRY VENEER

FLUID APPLIED AIR &

WATER BARRIER

STEEL LINTEL ANGLE,

PAINT TO MATCH

MASONRY VENEER

NOM 4" SPRAY

FOAM AIR

BARRIER

STEEL FRAME

CONT SEALANT

(BOTH SIDES)

SCHEDULED DOOR

107'-4"

TOP OF FRAME

MORTAR CONTROL

MESH

WEEPS

SEALANT

1 1/8"6"2"

5/8" 1/2"

6"1/2"2"3 1/2"3 5/8"

1/2" HORIZ

RESILIENT

CHANNELS AT 24"

OC VERTICALLY

5/8" GWB

6" CFMF AT 16" OC

1/2" EXT GYPSUM

SHEATHING

2" RIGID

INSULATION

MASONRY

ANCHORS

MASONRY

VENEER

NOM 4" SPRAY

FOAM AIR BARRIER

FLUID APPLIED AIR

& WATER BARRIER

STEEL FRAME

CONT SEALANT

(BOTH SIDES)

SCHEDULED DOOR

DOUBLE JAMB STUDS

(CLIP AT 12" OC VERT)

3 5/8" 3 1/2" 2" 1/2" 6" 1/2"

5/8"

7 5/8" 2" 6" 1 1/8"

1/2" RESILIENT

CHANNEL AT 24"

OC

5/8" GWB

6" CFMF AT 16" OC

1/2" EXT GYPSUM

SHEATHING

2" RIGID INSULATION

PREFINISHED METAL

FLASHING WITH DRIP

EDGE

MASONRY VENEER

FLUID APPLIED

VAPOR BARRIER

8x6x7/16" STEEL

LINTEL ANGLE -

PAINT TO MATCH

MASONRY VENEER

108'-8"

TOP OF FRAME

NOM 4" SPRAY

FOAM AIR BARRIER

STC-50 RATED

DOOR AND FRAME

ASSEMBLY

(107'-04" AT DR 125A)

MORTAR

CONTROL MESH

WEEPS

FILL SOLID W/ SOUND

DEADENING GROUT

MATERIAL

1/2" HORIZ RESILIENT

CHANNELS AT 24" OC

VERTICALLY

5/8" GWB

6" CFMF AT 16" OC

1/2" EXT

GYPSUM

SHEATHING

2" RIGID INSULATION

MASONRY

ANCHORS

MASONRY

VENEER

NOM 4" SPRAY FOAM

AIR BARRIER

FLUID APPLIED AIR &

WATER BARRIER

DOUBLE JAMB STUDS

(CLIP AT 12" OC VERT)

STC-50 RATED

PARTITION PER

PLAN

STC-50 RATED

DOOR AND FRAME

ASSEMBLY

FILL SOLID W/ SOUND

DEADENING GROUT

MATERIAL

CONT SEALANT

BOTH SIDES

1/2" HORIZ RESILIENT

CHANNELS AT 24" OC

VERTICALLY

5/8" GWB

6" CFMF AT 16" OC

1/2" EXT GYPSUM

SHEATHING

NOM 4" SPRAY FOAM

AIR BARRIER

FLUID APPLIED AIR &

WATER BARRIER

DOUBLE JAMB STUDS

(CLIP AT 12" OC VERT)

STC-50 RATED

PARTITION

PER PLAN

STC-50 RATED

DOOR AND FRAME

ASSEMBLY

FILL SOLID W/ SOUND

DEADENING GROUT

MATERIAL

1/2" PLYWOOD

FWP1 2" INSULATED

METAL WALL PANEL

NOM 4" SPRAY FOAM

AIR BARRIER

3" 16 GA HORIZ FURRING

CHANNEL AT 48" OC

VERTICALLY

1/2" RESILIENT

CHANNEL AT 24" OC

5/8" GWB

6" CFMF AT 16" OC

1/2" EXT GYPSUM

SHEATHING

PREFINISHED METAL

FLASHING WITH DRIP

EDGE

FLUID APPLIED

VAPOR BARRIER

108'-8"

TOP OF FRAME

NOM 4" SPRAY FOAM

AIR BARRIER

STC-50 RATED DOOR

AND FRAME

ASSEMBLY

PRE-FINISHED

EXTRUSION W/WEEP

HOLES

FWP1 2" INSULATED

METAL WALL PANEL

1/2" EXT GYPSUM

SHEATHING

1/2" PLYWOOD

CONT SEALANT

(BOTH SIDES)

FILL SOLID W/ SOUND

DEADENING GROUT

MATERIAL

3"

16 GA 3" HORIZ Z-

CHANNEL AT 48"

VERTICALLY

1/2" HORIZ

RESILIENT

CHANNELS AT 24"

OC VERTICALLY

5/8" GWB

6" CFMF AT 16" OC

1/2" EXT GYPSUM

SHEATHING

NOM 4" SPRAY

FOAM AIR BARRIER

FLUID APPLIED AIR

& WATER BARRIER

STEEL FRAME

CONT SEALANT

(BOTH SIDES)

SCHEDULED DOOR

DOUBLE JAMB STUDS

(CLIP AT 12" OC VERT)

FWP1 2" INSULATED

METAL WALL PANEL

1/2" PLYWOOD

SEALANT

2" 6" 1 1/8"

1/2" HORIZ

RESILIENT

CHANNELS AT 24"

OC VERTICALLY

5/8" GWB

6" CFMF AT 16" OC

1/2" EXT GYPSUM

SHEATHING

FWP1 2" INSULATED

METAL WALL PANEL

PRE-FINISHED

EXTRUSION W/WEEP

HOLES

FLUID APPLIED AIR &

WATER BARRIER

PRE-FINISHED METAL

FLASHING WITH DRIP

EDGE

NOM 4" SPRAY FOAM

AIR BARRIER

STEEL FRAME

CONT SEALANT

(BOTH SIDES)

SCHEDULED

DOOR

107'-4"

TOP OF FRAME

SEALANT

2" 3"

1/2" 6"

1/2" 5/8"

11 1/2" 8 3/8"

1 1/8"6"2"

1/2" HORIZ RESILIENT

CHANNELS AT 24" OC

VERTICALLY

5/8" GWB

6" CFMF AT 16" OC

1/2" EXT GYPSUM

SHEATHING

NOM 4" SPRAY FOAM

AIR BARRIER DOUBLE JAMB STUDS

(CLIP AT 12" OC VERT)

STC-50 RATED

DOOR AND FRAME

ASSEMBLY

FILL SOLID W/ SOUND

DEADENING GOUT

MATERIAL

1/2" PLYWOOD

FWP1 2" INSULATED

METAL WALL PANEL

3" 16 GA HORIZ FURRING

CHANNEL AT 48" OC

VERTICALLY

2" RIGID INSULATION

MASONRY

ANCHORS

MASONRY

VENEER

FLUID APPLIED AIR &

WATER BARRIER

STEEL STRUCTURE

FOR FUTURE DOOR

REPLACEMENT.

SEALANT

SEALANT

SEALANT

1/2" HORIZ RESILIENT

CHANNELS AT 24" OC

VERTICALLY

5/8" GWB

6" CFMF AT 16" OC

1/2" EXT GYPSUM

SHEATHING

NOM 4" SPRAY FOAM

AIR BARRIER

DOUBLE JAMB STUDS

(CLIP AT 12" OC VERT)

STC-50 RATED

DOOR AND FRAME

ASSEMBLY

FILL SOLID W/ SOUND

DEADENING GROUT

MATERIAL

1/2" PLYWOOD

FWP1 2" INSULATED

METAL WALL PANEL

3" 16 GA HORIZ FURRING

CHANNEL AT 48" OC

VERTICALLY

FLUID APPLIED AIR &

WATER BARRIER STEEL STRUCTURE

FOR FUTURE DOOR

REPLACEMENT.

METAL WALL PANEL

CONTROL JOINT.

ALIGN WITH EDGE OF

STEEL STRUCTURE.

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

Frankfurt-Short-Bruza Associates,P.C.

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

C

B

A

D

C

B

A

54321

20190310

NDM

Jo int

B as e S an

A nto nio

JB

SA

Ke lly

A nn ex , T ex as

Te xa s A ir

Na tio na l G ua rd

9t h

FW

F-1

6 M iss ion Tr ain ing

C en ter (M

TC

3" 9"6"0

3" = 1'-0"

C :\U sers\keisner\D ocum ents\90310_Arch_keisnerU

7YM

G .rvt

9/16/2024 10:33:41 AM

15 AUGUST 2024

DOOR DETAILS

AE603

MJT

BKG

GMD

SCALE: 3" = 1'-0"

HEAD DETAIL @ BRICKA4

SCALE: 3" = 1'-0"

JAMB DETAIL @ BRICKB4

SCALE: 3" = 1'-0"

HEAD DETAIL @ BRICKC4

SCALE: 3" = 1'-0"

JAMB DETAIL @ BRICKD4

LEGEND GRAPHIC VISUAL PLANE OF CONT AIR

BARRIER WHERE SHOWN ALL SHEETS

SCALE: 3" = 1'-0"

JAMB DETAIL @ WALL PANELD3

SCALE: 3" = 1'-0"

HEAD DETAIL @ WALL PANELC3

SCALE: 3" = 1'-0"

JAMB DETAIL @ WALL PANELB3

SCALE: 3" = 1'-0"

HEAD DETAIL @ WALL PANELA3SCALE: 3" = 1'-0"

PLAN DETAIL AT STC 50 DOORA1

SCALE: 3" = 1'-0"

PLAN DETAIL AT STC 50 DOORB1

NOTE: REFERENCE SPECIFICATION SECTIONS

07 05 23 AND 07 27 10.00 10 FOR DESCRIPTION

OF AIR BARRIER SYSTEM

1 Addendum 02 09/16/2024

1 1