AE603-DOOR DETAILS.pdf

PDF 296 KB Posted

Attached to
Construct Mission Training Center (MTC) Facility
Solicitation number
W50S78-24-B-0001
Issued by

About this file

This document contains detailed design drawings and specifications for the construction of a Mission Training Center (MTC) facility for the Texas Air National Guard at Joint Base San Antonio Lackland Air Force Base.

The key details are: The government is soliciting bids for a firm fixed-price contract to construct a 15,200 square foot FTU 4-ship F-16 MTC facility, including demolition, site work, utilities, HVAC, plumbing, electrical, and other work. The contract duration will be 540 calendar days. The solicitation includes a base bid as well as 8 specified options. Certain brand name items are required for compatibility with existing systems. This 100% small business set-aside project has a NAICS code of 236220 and an estimated value between $10-25 million. A site visit and pre-bid conference are scheduled in August 2024, and all questions/RFIs must be submitted 5 days prior to bid opening. The government will only distribute amendments electronically through the SAM.gov website.

View the file

Other files

File Type Posted
MTC - ABSTRACT Posted 24 Sep 24.pdf PDF
SF101-LOW ROOF FRAMING PLAN.pdf PDF
S-002-TYPICAL DETAILS.pdf PDF
01 45 35 - Special Inspections.pdf PDF
M-702 SCHEDULES.pdf PDF
23 05 48.19 - SEISMIC BRACING FOR HVAC.pdf PDF
SB102-SLAB AND WALL PLAN.pdf PDF
AE501-SECTION DETAILS.pdf PDF
AE502-SECTION DETAILS.pdf PDF
AE303-WALL SECTIONS.pdf PDF
23 05 48.00 40 - VIBRATION CONTROLS FOR HAC PIPING AND EQUIPMENT.pdf PDF
M-701 SCHEDULES.pdf PDF
AE601-ROOM FINISH SCHEDULE AND GLAZING TYPES AND MISC DETAILS.pdf PDF
AE101-FLOOR PLAN.pdf PDF
S-001-GENERAL NOTES.pdf PDF
AE305-WALL SECTIONS.pdf PDF
M-502 DETAILS.pdf PDF
AE001-PARTITION TYPES ANNOTATION SYMBOLS ABBREVIATIONS AND ACCESSIBILITY MOUNTING HEIGHTS.pdf PDF
C-301-REMOVAL PLAN.pdf PDF
New Utilities to East.pdf PDF
11 94 10 - Rooftop Fall Protection Anchors.pdf PDF
C-201-STORMWATER POLLUTION PREVENTION PLAN.pdf PDF
C-601-UTILITY PLAN.pdf PDF
000 TABLE OF CONTENTS.pdf PDF
M-501 DETAILS.pdf PDF
AE304-WALL SECTIONS.pdf PDF
SF102-HIGH ROOF FRAMING PLAN.pdf PDF
G-003-CODE AND LIFE SAFETY PLAN.pdf PDF
01 45 00 - Quality Control.pdf PDF
MTC RFI log 20240917.pdf PDF
AE401-ENLARGED PLANS AND DETAILS.pdf PDF
ES101-ELECTRICAL SITE PLAN.pdf PDF
AE503-SECTION DETAILS.pdf PDF
Amendment 0004 - 17 Aug 2024.pdf PDF
C-401-PROPOSED PLAN.pdf PDF
C-602-DRAINAGE SCHEDULE AND DETAILS.pdf PDF
W50S78-24-B-0001 - Mission Training Center Amendment 0003.pdf PDF
MTC RFI log.pdf PDF
W50S7824B0001 - MTC - Amendment 02 - 20240829.pdf PDF
Attachment 14 - Geotechnical report-TX ANG Mission Training Center B-3.pdf PDF
MFR Mission Training Center - 2nd Site Visit Pre-Propsal Conference Minutes.pdf PDF
Pre_Bid_Site Visit_MTC_Attendance_Sheet 27_Aug _2024.pdf PDF
Pre-Proposal Site Visit Slides - MTC 27 Aug 24.pptx PPTX presentation
W50S78-24-B-0001 - Mission Training Center Amendment 0001.pdf PDF
2024.08.21_TX-ANG_149TH MISSION TRAINING CENTER_REVISED B3_VOL 1 SPECIFICATIONS.pdf PDF
ATTACHMENT 9 SPECS V1 ADDENDUM.pdf PDF
MTC RFI log.pdf PDF
Pre-Proposal Site Visit Slides - MTC 20 Aug 24 (002).pptx PPTX presentation
Pre_Bid_Site Visit_MTC_Attendance_Sheet 20_Aug _2024.pdf PDF
MFR Mission Training Center - Site Visit Pre-Propsal Conference Minutes.pdf PDF
Show 40 more

Latest 50 of 63 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1/2" HORIZ

RESILIENT

CHANNELS AT 24"

OC VERTICALLY

5/8" GWB

6" CFMF AT 16" OC

1/2" EXT GYPSUM

SHEATHING

2" RIGID INSULATION

PREFINISHED METAL

FLASHING

MASONRY VENEER

FLUID APPLIED AIR &

WATER BARRIER

STEEL LINTEL ANGLE,

PAINT TO MATCH

MASONRY VENEER

NOM 4" SPRAY

FOAM AIR

BARRIER

STEEL FRAME

CONT SEALANT

(BOTH SIDES)

SCHEDULED DOOR

107'-4"

TOP OF FRAME

MORTAR CONTROL

MESH

WEEPS

SEALANT

1 1/8"6"2"

5/8" 1/2"

6"1/2"2"3 1/2"3 5/8"

1/2" HORIZ

RESILIENT

CHANNELS AT 24"

OC VERTICALLY

5/8" GWB

6" CFMF AT 16" OC

1/2" EXT GYPSUM

SHEATHING

2" RIGID

INSULATION

MASONRY

ANCHORS

MASONRY

VENEER

NOM 4" SPRAY

FOAM AIR BARRIER

FLUID APPLIED AIR

& WATER BARRIER

STEEL FRAME

CONT SEALANT

(BOTH SIDES)

SCHEDULED DOOR

DOUBLE JAMB STUDS

(CLIP AT 12" OC VERT)

3 5/8" 3 1/2" 2" 1/2" 6" 1/2"

5/8"

7 5/8" 2" 6" 1 1/8"

1/2" RESILIENT

CHANNEL AT 24"

OC

5/8" GWB

6" CFMF AT 16" OC

1/2" EXT GYPSUM

SHEATHING

2" RIGID INSULATION

PREFINISHED METAL

FLASHING WITH DRIP

EDGE

MASONRY VENEER

FLUID APPLIED

VAPOR BARRIER

8x6x7/16" STEEL

LINTEL ANGLE -

PAINT TO MATCH

MASONRY VENEER

108'-8"

TOP OF FRAME

NOM 4" SPRAY

FOAM AIR BARRIER

STC-50 RATED

DOOR AND FRAME

ASSEMBLY

(107'-04" AT DR 125A)

MORTAR

CONTROL MESH

WEEPS

FILL SOLID W/ SOUND

DEADENING GROUT

MATERIAL

1/2" HORIZ RESILIENT

CHANNELS AT 24" OC

VERTICALLY

5/8" GWB

6" CFMF AT 16" OC

1/2" EXT

GYPSUM

SHEATHING

2" RIGID INSULATION

MASONRY

ANCHORS

MASONRY

VENEER

NOM 4" SPRAY FOAM

AIR BARRIER

FLUID APPLIED AIR &

WATER BARRIER

DOUBLE JAMB STUDS

(CLIP AT 12" OC VERT)

STC-50 RATED

PARTITION PER

PLAN

STC-50 RATED

DOOR AND FRAME

ASSEMBLY

FILL SOLID W/ SOUND

DEADENING GROUT

MATERIAL

CONT SEALANT

BOTH SIDES

1/2" HORIZ RESILIENT

CHANNELS AT 24" OC

VERTICALLY

5/8" GWB

6" CFMF AT 16" OC

1/2" EXT GYPSUM

SHEATHING

NOM 4" SPRAY FOAM

AIR BARRIER

FLUID APPLIED AIR &

WATER BARRIER

DOUBLE JAMB STUDS

(CLIP AT 12" OC VERT)

STC-50 RATED

PARTITION

PER PLAN

STC-50 RATED

DOOR AND FRAME

ASSEMBLY

FILL SOLID W/ SOUND

DEADENING GROUT

MATERIAL

1/2" PLYWOOD

FWP1 2" INSULATED

METAL WALL PANEL

NOM 4" SPRAY FOAM

AIR BARRIER

3" 16 GA HORIZ FURRING

CHANNEL AT 48" OC

VERTICALLY

1/2" RESILIENT

CHANNEL AT 24" OC

5/8" GWB

6" CFMF AT 16" OC

1/2" EXT GYPSUM

SHEATHING

PREFINISHED METAL

FLASHING WITH DRIP

EDGE

FLUID APPLIED

VAPOR BARRIER

108'-8"

TOP OF FRAME

NOM 4" SPRAY FOAM

AIR BARRIER

STC-50 RATED DOOR

AND FRAME

ASSEMBLY

PRE-FINISHED

EXTRUSION W/WEEP

HOLES

FWP1 2" INSULATED

METAL WALL PANEL

1/2" EXT GYPSUM

SHEATHING

1/2" PLYWOOD

CONT SEALANT

(BOTH SIDES)

FILL SOLID W/ SOUND

DEADENING GROUT

MATERIAL

3"

16 GA 3" HORIZ Z-

CHANNEL AT 48"

VERTICALLY

1/2" HORIZ

RESILIENT

CHANNELS AT 24"

OC VERTICALLY

5/8" GWB

6" CFMF AT 16" OC

1/2" EXT GYPSUM

SHEATHING

NOM 4" SPRAY

FOAM AIR BARRIER

FLUID APPLIED AIR

& WATER BARRIER

STEEL FRAME

CONT SEALANT

(BOTH SIDES)

SCHEDULED DOOR

DOUBLE JAMB STUDS

(CLIP AT 12" OC VERT)

FWP1 2" INSULATED

METAL WALL PANEL

1/2" PLYWOOD

SEALANT

2" 6" 1 1/8"

1/2" HORIZ

RESILIENT

CHANNELS AT 24"

OC VERTICALLY

5/8" GWB

6" CFMF AT 16" OC

1/2" EXT GYPSUM

SHEATHING

FWP1 2" INSULATED

METAL WALL PANEL

PRE-FINISHED

EXTRUSION W/WEEP

HOLES

FLUID APPLIED AIR &

WATER BARRIER

PRE-FINISHED METAL

FLASHING WITH DRIP

EDGE

NOM 4" SPRAY FOAM

AIR BARRIER

STEEL FRAME

CONT SEALANT

(BOTH SIDES)

SCHEDULED

DOOR

107'-4"

TOP OF FRAME

SEALANT

2" 3"

1/2" 6"

1/2" 5/8"

11 1/2" 8 3/8"

1 1/8"6"2"

1/2" HORIZ RESILIENT

CHANNELS AT 24" OC

VERTICALLY

5/8" GWB

6" CFMF AT 16" OC

1/2" EXT GYPSUM

SHEATHING

NOM 4" SPRAY FOAM

AIR BARRIER DOUBLE JAMB STUDS

(CLIP AT 12" OC VERT)

STC-50 RATED

DOOR AND FRAME

ASSEMBLY

FILL SOLID W/ SOUND

DEADENING GOUT

MATERIAL

1/2" PLYWOOD

FWP1 2" INSULATED

METAL WALL PANEL

3" 16 GA HORIZ FURRING

CHANNEL AT 48" OC

VERTICALLY

2" RIGID INSULATION

MASONRY

ANCHORS

MASONRY

VENEER

FLUID APPLIED AIR &

WATER BARRIER

STEEL STRUCTURE

FOR FUTURE DOOR

REPLACEMENT.

SEALANT

SEALANT

SEALANT

1/2" HORIZ RESILIENT

CHANNELS AT 24" OC

VERTICALLY

5/8" GWB

6" CFMF AT 16" OC

1/2" EXT GYPSUM

SHEATHING

NOM 4" SPRAY FOAM

AIR BARRIER

DOUBLE JAMB STUDS

(CLIP AT 12" OC VERT)

STC-50 RATED

DOOR AND FRAME

ASSEMBLY

FILL SOLID W/ SOUND

DEADENING GROUT

MATERIAL

1/2" PLYWOOD

FWP1 2" INSULATED

METAL WALL PANEL

3" 16 GA HORIZ FURRING

CHANNEL AT 48" OC

VERTICALLY

FLUID APPLIED AIR &

WATER BARRIER STEEL STRUCTURE

FOR FUTURE DOOR

REPLACEMENT.

METAL WALL PANEL

CONTROL JOINT.

ALIGN WITH EDGE OF

STEEL STRUCTURE.

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

Frankfurt-Short-Bruza Associates,P.C.

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

C

B

A

D

C

B

A

54321

20190310

NDM

Jo int

B as e S an

A nto nio

JB

SA

Ke lly

A nn ex , T ex as

Te xa s A ir

Na tio na l G ua rd

9t h

FW

F-1

6 M iss ion Tr ain ing

C en ter (M

TC

3" 9"6"0

3" = 1'-0"

C :\U sers\keisner\D ocum ents\90310_Arch_keisnerU

7YM

G .rvt

9/16/2024 10:33:41 AM

15 AUGUST 2024

DOOR DETAILS

AE603

MJT

BKG

GMD

SCALE: 3" = 1'-0"

HEAD DETAIL @ BRICKA4

SCALE: 3" = 1'-0"

JAMB DETAIL @ BRICKB4

SCALE: 3" = 1'-0"

HEAD DETAIL @ BRICKC4

SCALE: 3" = 1'-0"

JAMB DETAIL @ BRICKD4

LEGEND GRAPHIC VISUAL PLANE OF CONT AIR

BARRIER WHERE SHOWN ALL SHEETS

SCALE: 3" = 1'-0"

JAMB DETAIL @ WALL PANELD3

SCALE: 3" = 1'-0"

HEAD DETAIL @ WALL PANELC3

SCALE: 3" = 1'-0"

JAMB DETAIL @ WALL PANELB3

SCALE: 3" = 1'-0"

HEAD DETAIL @ WALL PANELA3SCALE: 3" = 1'-0"

PLAN DETAIL AT STC 50 DOORA1

SCALE: 3" = 1'-0"

PLAN DETAIL AT STC 50 DOORB1

NOTE: REFERENCE SPECIFICATION SECTIONS

07 05 23 AND 07 27 10.00 10 FOR DESCRIPTION

OF AIR BARRIER SYSTEM

1 Addendum 02 09/16/2024

1 1

File details come from the government source that posted it. Updated .