AE001-PARTITION TYPES ANNOTATION SYMBOLS ABBREVIATIONS AND ACCESSIBILITY MOUNTING HEIGHTS.pdf

PDF 148 KB Posted

Attached to
Construct Mission Training Center (MTC) Facility Federal contract opportunity
Solicitation number
W50S78-24-B-0001
Issued by
Department of the Army National Guard

About this file

This document appears to be a set of architectural drawings and annotations related to partition types, symbols, abbreviations, and accessibility mounting heights for a federal contract opportunity.

The key details are:

  • The drawings provide specifications and details for various rated and non-rated interior partition types, including steel stud, concrete masonry unit, and radio frequency (RF) shielded partitions.
  • It includes an annotation legend, architectural abbreviations, and specifications for installation and materials.
  • The document also includes an accessibility mounting height schedule for plumbing fixtures and accessories.
  • This appears to be supporting documentation for a federal contract opportunity, but the document does not contain details about the contract itself, such as a solicitation, requirements, or proposal instructions.

View the file

Other files for this federal contract opportunity

Other files attached to Construct Mission Training Center (MTC) Facility, newest first.
File Type Posted
MTC - ABSTRACT Posted 24 Sep 24.pdf PDF
C-301-REMOVAL PLAN.pdf PDF
S-002-TYPICAL DETAILS.pdf PDF
SF101-LOW ROOF FRAMING PLAN.pdf PDF
S-001-GENERAL NOTES.pdf PDF
New Utilities to East.pdf PDF
M-501 DETAILS.pdf PDF
AE501-SECTION DETAILS.pdf PDF
AE305-WALL SECTIONS.pdf PDF
C-401-PROPOSED PLAN.pdf PDF
C-602-DRAINAGE SCHEDULE AND DETAILS.pdf PDF
ES101-ELECTRICAL SITE PLAN.pdf PDF
AE401-ENLARGED PLANS AND DETAILS.pdf PDF
AE503-SECTION DETAILS.pdf PDF
01 45 00 - Quality Control.pdf PDF
Amendment 0004 - 17 Aug 2024.pdf PDF
MTC RFI log 20240917.pdf PDF
C-201-STORMWATER POLLUTION PREVENTION PLAN.pdf PDF
C-601-UTILITY PLAN.pdf PDF
SF102-HIGH ROOF FRAMING PLAN.pdf PDF
G-003-CODE AND LIFE SAFETY PLAN.pdf PDF
M-702 SCHEDULES.pdf PDF
M-701 SCHEDULES.pdf PDF
AE601-ROOM FINISH SCHEDULE AND GLAZING TYPES AND MISC DETAILS.pdf PDF
AE303-WALL SECTIONS.pdf PDF
23 05 48.19 - SEISMIC BRACING FOR HVAC.pdf PDF
23 05 48.00 40 - VIBRATION CONTROLS FOR HAC PIPING AND EQUIPMENT.pdf PDF
W50S78-24-B-0001 - Mission Training Center Amendment 0003.pdf PDF
Attachment 14 - Geotechnical report-TX ANG Mission Training Center B-3.pdf PDF
MTC RFI log.pdf PDF
W50S7824B0001 - MTC - Amendment 02 - 20240829.pdf PDF
Pre-Proposal Site Visit Slides - MTC 27 Aug 24.pptx PPTX presentation
MFR Mission Training Center - 2nd Site Visit Pre-Propsal Conference Minutes.pdf PDF
Pre_Bid_Site Visit_MTC_Attendance_Sheet 27_Aug _2024.pdf PDF
MTC RFI log.pdf PDF
2024.08.21_TX-ANG_149TH MISSION TRAINING CENTER_REVISED B3_VOL 1 SPECIFICATIONS.pdf PDF
ATTACHMENT 9 SPECS V1 ADDENDUM.pdf PDF
Pre-Proposal Site Visit Slides - MTC 20 Aug 24 (002).pptx PPTX presentation
Pre_Bid_Site Visit_MTC_Attendance_Sheet 20_Aug _2024.pdf PDF
Attachment 6_Industrial Security.pdf PDF
Attachment 5_STRUCTURAL INTERIOR DESIGN.pdf PDF
Attachment 7_ACCESS AND STAGING SITE PLAN.pdf PDF
JA Nm Brand DDC Redacted.pdf PDF
JA Nm Brand Falcon Redacted.pdf PDF
2024.08.15_TX-ANG_149TH MISSION TRAINING CENTER_REVISED B3_VOL 1 SPECIFICATIONS.pdf PDF
JA Nm Brand Vindicator Sys Redacted.pdf PDF
W50S78-24-B-0001 - Mission Training Center Solicitation.pdf PDF
2024.08.15_TX-ANG_149TH MISSION TRAINING CENTER_REVISED B3_DRAWINGS.pdf PDF
JA Nm Brand Monaco Redacted.pdf PDF
JA Nm Brand Trane HVAC Redacted.pdf PDF
Show all 50

Construct Mission Training Center (MTC) Facility has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NON-RATED PARTITION

NON-RATED PARTITION AS SHOWN WITH

UNFACED BLANKET INSULATIONA2

A1

5/8" GWB

(BOTH SIDES)

CONCRETE

SLAB

STEEL

DECK

DEFLECTION

TRACK

SCHEDULED

CEILING

STEEL RUNNER

CHANNEL

SCHEDULED

BASE

3 5/8" STEEL

STUDS

5/8" GWB

(2 LAYERS)

1 HR RATED PARTITION

STC DESIGN: GA WP 1052 SYSTEM - STC 50-54

SOUND TEST RE: NRCC 817-NV (DESIGN NO. UL - V465)

S1

CONCRETE

SLAB

STEEL

DECK

SCHEDULED CLG

STEEL RUNNER CHANNEL

3-5/8" STEEL

STUDS

SCHEDULED BASE

UNFACED

BLANKET

INSULATION

DEFLECTION

TRACK

SECURE SIDENON-SECURE SIDE

(WHERE APPLICABLE)

NOTE: THERE IS SCHEDULED FINISH ABOVE THE

CEILINGS - REFER TO THE ROOM FINISH SCHEDULE.

1"

A3

NON-RATED PARTITION AS SHOWN WITH

6" STEEL STUDS AND UNFACED

BLANKET INSULATION

CONCRETE

SLAB

ADJACENT

CONSTRUCTION

TO BE FURRED

NON-RATED FURRING PARTITION

NON-RATED FURRING PARTITION AS

SHOWN WITH 3 5/8" STEEL STUDS

B2

B1

SCHEDULED

CEILING

STEEL RUNNER

CHANNEL

SCHEDULED

BASE

STEEL CLIP ANGLES

AT 32" OC (MATCH

STUD GAUGE)

6"

STEEL RUNNER

CHANNEL

2 1/2" STEEL

STUDS

8" CMU

1 HR. RATED PARTITION

PER UFC 1-200-01, UFC 3-600-01

AND IBC TABLE 721.1, MATERIAL 3

(CONCRETE MASONRY UNITS)

DESIGN No U907 - ANSI/UL 263

C1

STRUCTURAL

BRACING. REF

A3/S-004

1 HR RATED PARTITION AS SHOWN WITH 6" STEEL

STUDS AND UNFACED BLANKET INSULATION

STC DESIGN: GA WP 1052 SYSTEM - STC 50-54

SOUND TEST RE: NRCC 817-NV (DESIGN NO. UL - V465)

S2

1 HR RATED PARTITION AS SHOWN WITH 8" STEEL

STUDS AND UNFACED BLANKET INSULATION

STC DESIGN: GA WP 1052 SYSTEM - STC 50-54

SOUND TEST RE: NRCC 817-NV (DESIGN NO. UL - V465)

S3

5/8" GWB (BOTH

SIDES)

D1 1 HR RATED PARTITION

(DESIGN NO. UL - U419)

CONCRETE

SLAB

STEEL

DECK

DEFLECTION TRACK

SCHEDULED CLG

STEEL RUNNER

CHANNEL6" STEEL

STUDS

SCHEDULED

BASE

FIRE CAULK

(BOTH SIDES)

1"

1"

1"

CONCRETE

SLAB

ACOUSTICAL

INSULATION INFILL

FIRE CAULK (BOTH SIDES)

FLEXIBLE SPRAY

(BOTH SIDES)

STEEL

DECK

PROVIDE UL JOINT

ASSEMBLY HW-

D-0042 TO DECK

PROVIDE UL JOINT

ASSEMBLY HW-

D-0042 TO DECK

PROVIDE UL JOINT

ASSEMBLY HW-

D-0042 TO DECK

NON-RATED FURRING PARTITION AS

SHOWN WITH 3 5/8" STEEL STUDS AND

UNFACED BLANKET INSULATION

B3

A4

NON-RATED PARTITION AS SHOWN WITH

8" STEEL STUDS AND UNFACED

BLANKET INSULATION

PERFORATED RF

SHIELDING/FOIL MEMBRANE

(FOR S3f ONLY)

A1

AE001

1 HR RATED PARTITION AS SHOWN WITH 8" STEEL

STUDS, UNFACED BLANKET INSULATION AND

RF SHIELDING/FOIL MEMBRANE

STC DESIGN: GA WP 1052 SYSTEM - STC 50-54

SOUND TEST RE: NRCC 817-NV (DESIGN NO. UL - V465)

S3f

3'-0" 6"

2'-0" 1'-0"

3"

WATER CLOSET

GRAB BAR

SANITARY NAPKIN

DISPOSAL

TOILET TISSUE

DISPENSER

TOILET SEAT

COVER

DISPENSER

ACCESSIBLE WATER

CLOSET BACK WALL

ACCESSIBLE WATER

CLOSET SIDE WALL

1'-4"

3' -4

LAVATORY

SOAP

DISPENSER

MIRROR

WALL MOUNTED

LAVATORY

M

AX

A

FF

SP

O

U T

- 3 6"

M

AX

A

FF

SP

O

U T

- 4 3"

3' -4

1'-0" 3'-6"

3' -0

3"

DESCRIPTION MOUNTING HEIGHT

WATER CLOSET 15" AFF TO RIM

WATER CLOSET - ACCESSIBLE 17" AFF TO RIM

URINAL 24" AFF TO RIM

URINAL - ACCESSIBLE 17" AFF TO RIM

LAVATORY 34" AFF TO TOP

PAPER TOWEL DISPENSER 46" AFF TO BOTTOM OF DISPENSER

SANITARY NAPKIN DISPOSAL 28" AFF TO TOP

TOILET PAPER DISPENSER 28" AFF TO TOP

GRAB BAR 34.5" AFF TO CENTER

ROBE HOOK/TOWEL BAR 60" AFF TO TOP

ROBE HOOK/TOWEL BAR -

ACCESSIBLE

48" AFF TO TOP

TOILET SEAT COVER DISPENSER 28" AFF TO TOP

ACCESSIBILITY, PLUMBING FIXTURE, TOILET

ACCESSORY CLEARANCES AND MOUNTING HEIGHTS

2' -1

0" C

LE

AR

TOILET ACCESSORY MOUNTING HEIGHT SCHEDULE

EDGE OF WALL

1'-3" 1'-3"

FIXTURE

CLEARANCE

1'-3" 1'-3"

CLEARANCEFLUSH VALVE

1- 1/

2" M

IN

URINAL

FLUSH VALVE

ACCESSIBLE WATER

COOLERS

ACCESSIBLE

URINALS

EDGE OF LAV

4'-0" MIN TO

HAND DRYER

BABY CHANGING STATION 48" AFF TO TOP

15" AFF TO BOTTOM

2' -1

0"

SEMI-RECESSED

WASTE RECEPTACLE

4' -0

SANITARY NAPKIN

VENDOR

NOTE: NOT ALL TOILET ACCESSORIES MAY BE USED IN PROJECT.

COAT HOOK 60" AFF TO TOP

COAT HOOK - ACCESSIBLE 48" AFF TO TOP

1/

2" M

IN

M

AX

1' -5

1' - 6"

7"

M

AX

1'

5"

ACT ACOUSTICAL CEILING TILE

ADA AMERICANS WITH DISABILITIES ACT

ADAAG ADA ACCESSIBILITY GUIDELINES

AFF ABOVE CONCRETE SLAB

AHU AIR HANDLING UNIT

ALT ALTERNATE

ALUM ALUMINUM

ANSI AMERICAN NATIONAL STANDARDS

INSTITUTE

BO BOTTOM OF

BOT BOTTOM

BRG BEARING

BS BOTH SIDES

BTWN BETWEEN

CAB CABINET

CFMF COLD-FORMED METAL FRAMING

CG CORNER GUARD

CJ CONTROL JOINT

CL CENTER LINE

CLG CEILING

CLR CLEAR

CMU CONCRETE MASONRY UNIT

COL COLUMN

CONC CONCRETE

CONT CONTINUOUS

CORR CORRIDOR

CPT CARPET

CTB CERAMIC TILE BASE

CWT CERAMIC WALL TILE

CTR CENTER

DBL DOUBLE

DEG DEGREE

DEMO DEMOLITION

DEPT DEPARTMENT

DF DRINKING FOUNTAIN

DIA DIAMETER

DIAG DIAGONAL

DIM DIMENSION

DISP DISPENSER

DN DOWN

DR DOOR

DS DOWNSPOUT

DET DETAIL

DWG DRAWING

EA EACH

EIFS EXTERIOR INSULATION FINISH

SYSTEM

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRIC (OR) ELECTRICAL

ELEV ELEVATOR

EQ EQUAL

EQUIP EQUIPMENT

EW EACH WAY

EXIST EXISTING

EXT EXTERIOR

FD FLOOR DRAIN

FE FIRE EXTINGUISHER

FF EL CONCRETE SLAB ELEVATION

FG FINISHED GRADE

FLR FLOOR

FLUOR FLUORESCENT

FR FIRE RESISTIVE

FT FOOT (OR) FEET

FURG FURRING

GA GAUGE

GALV GALVANIZED

GB GRAB BAR

GC GENERAL CONTRACTOR

GDR GUARD RAIL

GEN GENERAL

GL GLASS

GRD GRADE

GWB GYPSUM BOARD

HM HOLLOW METAL

HORIZ HORIZONTAL

HT HEIGHT

HVAC HEATING, VENTILATING, &

AIR CONDITIONING

ID INSIDE DIAMETER

INSUL INSULATE (OR) INSULATION

INT INTERIOR

IMWP INSULATED METAL WALL PANEL

JAN JANITOR

K NOT USED

LAM LAMINATE

LAV LAVATORY

LIN LINEAR

LOC LOCATION

LTG LIGHTING

LVR LOUVER

MATL MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MFR MANUFACTURER

MIN MINIMUM

MIRR MIRROR

MISC MISCELLANEOUS

MO MASONRY OPENING

MTD MOUNTED

MTL METAL

NA NOT APPLICABLE

NIC NOT IN CONTRACT

NOM NOMINAL

NRC NOISE REDUCTION COEFFICIENT

NTS NOT TO SCALE

OA OVERALL

OC ON CENTER

OD OUTSIDE DIAMETER

OFCI OWNER FURNISHED

CONTRACTOR INSTALLED

OFOI OWNER FURNISHED

OWNER INSTALLED

OH OPPOSITE HAND

ORD OVERFLOW ROOF DRAIN

OVHD OVERHEAD

PLAM PLASTIC LAMINATE

PLBG PLUMBING

PLYWD PLYWOOD

PR PAIR

PRCST PRECAST

PREFAB PREFABRICATED

PREFIN PREFINISHED

PROT PROTECTION

PNTD PAINTED

PVC POLYVINYL CHLORIDE

QTF QUARRY TILE FLOOR

QTB QUARRY TILE BASE

QTY QUANTITY

R RADIUS (OR) RISER

RB RESILIENT BASE

RD ROOF DRAIN

REC RECESSED

REF REFERENCE (OR) REFRIGERATOR

REQD REQUIRED

REV REVISION

RF RESILIENT FLOORING

RM ROOM

RO ROUGH OPENING

SECT SECTION

SF SQUARE FOOT

SHTHG SHEATHING

SIM SIMILAR

SPEC SPECIFICATION(S)

SST STAINLESS STEEL

SSSR STEEL STANDING SEAM ROOFING

STC SOUND TRANSMISSION

CLASSIFICATION

STD STANDARD

STL STEEL

STRUCT STRUCTURAL (OR) STRUCTURE

T TREAD

T&B TOP AND BOTTOM

TBD TO BE DETERMINED

TD TOWEL DISPENSER

TO TOP OF

TOC TOP OF CONCRETE

TOJ TOP OF JOIST

TOM TOP OF MASONRY

TOS TOP OF STEEL

TYP TYPICAL

UNO UNLESS NOTED OTHERWISE

VB VINYL BASE

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VTR VENT THROUGH ROOF

VWC VINYL WALL COVERING

W/ WITH

W/O WITHOUT

WC WATER CLOSET

WD WOOD

WH WALL HYDRANT (OR) WATER HEATER

XFMR TRANSFORMER

Y NOT USED

Z NOT USED

ARCHITECTURAL ABBREVIATIONS

A. ALL INTERIOR STC 50 RATED PARTITIONS - STEEL

STUDS SHALL BE 16 GAUGE AT 16" OC INCLUDING 16

GAUGE BOTTOM RUNNER CHANNELS AND 3" LONG

LEG 16 GAUGE DEFLECTION TOP TRACK WITH 16

GAUGE UPPER HORIZONTAL SPACER BARS.

B. ALL INTERIOR NON-STC 50 RATED PARTITIONS -

STEEL STUDS SHALL BE 16 GAUGE AT 16" OC

INCLUDING 20 GAUGE BOTTOM RUNNER CHANNELS

AND CONT 3" LONG LEG 20 GAUGE DEFLECTION TOP

TRACK AND 20 GAUGE UPPER HORIZONTAL SPACER

BARS.

C. ALL GYPSUM WALL BOARD SHALL BE CUT TIGHT TO

FIT AND SEALED COMPLETELY AIRTIGHT WITH

REQUIRED SEALANT FOR EITHER FIRE RATING OR

SOUND ATTENUATION AT ALL PENETRATIONS THRU

INTERIOR PARTITIONS SCHEDULED WITH FULL

HEIGHT GYPSUM WALL BOARD ON ONE OR BOTH

SIDES.

D. FILL ALL PERIMETER VOIDS AND HEAD OF WALL

METAL DECK FLUTES TO ACHIEVE COMPLETE

CLOSURE AND SEAL BOTH SIDES - UNO.

E. ALL UNFACED BLANKET INSULATION WHERE

INDICATED SHALL: (1) FILL THE ENTIRE STUD CAVITY

WIDTH AND THICKNESS. (2) BE INSTALLED

VERTICALLY CONTINOUS. (3) BE CUT TIGHT TO FIT

WITH NO VOIDS. (4) BE ADHERED IN PLACE TO

PREVENT SLIPPAGE DOWN THE CAVITY.

F. ALL GWB SHALL BE TYPE 'X' FIRE-RATED

REGARDLESS OF WHETHER OR NOT THE WALL IS

FIRE-RATED.

G. ALL GWB SHALL BE 5/8" TYPE "X" FIRE RESISTANT.

U.N.O.

TYPICAL PARTITION NOTES

GROUND FLOOR PLAN

SCALE:1/8"=1'-0"

A401

1.1 - A - 101

DRAWING TYPES LEGEND

0- GENERAL INFORMATION

1 - PLANS (HORIZONTAL VIEWS)

2 - ELEVATIONS (VERTICAL VIEWS)

3 - SECTIONS (SECTIONAL VIEWS)

4 - ENLARGED VIEWS (PLANS, ELEVATIONS OR SECTIONS)

5 - DETAILS

6 - SCHEDULES & DIAGRAMS

DISCIPLINE TYPE (ARCHITECTURE SHOWN)

DRAWING TYPE (PLAN, ELEVATION, ETC.)

SERIES/ FLOOR DESIGNATION

DETAIL CALLOUT

ENLARGED PLAN OR DETAIL

ON SHEET INDICATED

A201

INTERIOR ELEVATION CALLOUT

ARROWS INDICATE INTERIOR

ELEVATION ON SHEET

INDICATED

STRUCTURAL GRIDS

AS INDICATED ON

DRAWINGS

A

BUILDING SECTION CALLOUT

ARROWS INDICATE BUILDING

SECTION ON SHEET INDICATED

A301

SECTION CALLOUT

ARROW INDICATE WALL SECTION ON

SHEET INDICATED

A302

ROOM NAME

ROOM NAME & NUMBER SYMBOL

REFER TO ROOM FINISH SCHEDULE

101A

DOOR NUMBER SYMBOL

REFER TO DOOR SCHEDULE

PARTITION TYPE SYMBOL

REFER TO PARTITION TYPES

GLAZING TYPE SYMBOL

REFER TO GLAZING TYPES

A

AL1

REVISION SYMBOL

REFER TO SHEET BORDER FOR

REVISION HISTORY

ELEVATION DATUM SYMBOL

INDICATES DATUM ELEVATION AS

INDICATED

DISCIPLINE MODIFIER (ELEMENTS SHOWN)

ARCHITECTURAL SYMBOLS LEGEND

DRAWING TITLE

0 4' 8' 16'

1/8" = 1'-0"

NORTH ARROW AND SCALE

A301

EXTERIOR ELEVATION CALLOUT

ARROW INDICATE ELEVATION ON

SHEET INDICATED

A201

N

N N

PACKAGE

PHASE

112.01A

SUB-ROOM NUMBER

FLOOR LEVEL

KEYNOTE SYMBOL

INDICATES

INFORMATION FOUND

IN KEYNOTES ON PLAN

3 DIGIT ROOM NUMERAL

OFFICE SUITE DESIGNATION

LOCATED IN THE

BOTTOM RIGHT

SHEET CORNER

0 2' 4' 8'

1/4" = 1'-0"

WHERE THERE IS AN ACCESSIBLE CONCEALED FLOOR,

FLOOR-CEILING OR ATTIC SPACE, FIRE WALLS, FIRE

BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS AND

SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED

TO HAVE PROTECTED OPENINGS OR PENETRATIONS

SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED

WITH SIGNS OR STENCILING IN THE CONCEALED SPACE

ABOVE INSTALLED CEILING. SUCH IDENTIFICATION

SHALL:

1. BE LOCATED WITHIN 15'-0" OF THE END OF EACH

WALL AND AT INTERVALS NOT EXCEEDING 30'-0"

MEASURED HORIZONTALLY ALONG THE WALL OR

PARTITION.

2. INCLUDE LETTERING NOT LESS THAN 3 INCHES IN

HEIGHT WITH A MINIMUM 3/8 INCH STROKE IN A

CONTRASTING COLOR INCORPORATING THE

SUGGESTED WORDING, "FIRE BARRIER-PROTECT

ALL OPENINGS," OR OTHER WORDING.

MARKING & IDENTIFICATION

UFC 3-600-01 SECTION 7-2 & IBC 2021 SECTION 703.7

NOTE: IN SPACE WITH NO CEILING THE MARKINGS

SHALL BE 12'-0" ABOVE FINISHED FLOOR. MARKING

SHALL BE LEVEL. LETTER COLOR SHALL BE RED.

MARKING SHALL BE ON BOTH SIDES OF THE WALL OR

PARTITION.

A. REFERENCE SHEET AE520 FOR TYPICAL RF

SHIELDING/FOIL MEMBRANE NOTES AND DETAILS.

B. REFERENCE SPECIFICATIONS SECTION 13 49 21

RADIO FREQUENCY (RF) SHIELDING.

RF SHIELDED PARTITION NOTES

A. PIPE AND CONDUIT PENETRATIONS MUST HAVE NON-

CONDUCTIVE UNIONS.

B. MAN BARS MUST BE INSTALLED FOR OPENINGS

GREATER THAN 96 SQUARE INCHES.

C. PENETRATIONS THROUGH STC RATED WALLS MUST

BE GROUNDED ON BOTH SIDES OF THE WALL.

D. WALL PENETRATIONS BETWEEN NON-SECURE AND

SECURE AREA 1 ARE TO BE KEPT TO A MINIMUM. ANY

CONDUITS TO FEED EXTERIOR LIGHTING AND

CAMERAS ATTACHED TO THE OUTSIDE PERIMETER

OF THE SECURE AREA 1 ARE DESIGNED TO RUN ON

THE EXTERIOR OF THE BUILDING TO MINIMIZE WALL

PENETRATION. REFER TO DETAIL

E. REFERENCE SHEET AE002 FOR OUTLINE OF SECURE

PERIMETER WALLS.

SECURE PERIMETER NOTES

D1 / AE303

1" D

EF

1/ 2"

CONT 16 GA CFMF LONG LEG DEF TRACK

MINERAL WOOL INSULATION,

PROVIDE UL JOINT ASSEMBLY

HW-D-0042 TO DECK FOR FIRE

RATED WALL CONDITION

2 LAYERS 5/8" GWB (BOTH SIDES)

SPRAY APPLIED FILL MATERIAL ON

EACH SIDE TO COMPLETELY COVER

MINERAL WOOL BATT INSULATION

CONT 20 GA GALV DECK FLUTE FILLERS ON EACH

SIDE WITH HORIZ FLAT SURFACE FOR ATTACHMENT

TO BOTTOM FACE OF DECK (NOTE: PROVIDE CONT

CLIP ANGLE ON EACH SIDE FOR PARTITIONS

PARALLEL TO DECK FLUTES)

CONT 20 GA GALV CLIP ANGLE FOR SECURITY

CLOSURE PROTECTION OF SPRAY APPLIED FILL

MATERIAL (NOTE: MOUNT SNUG AGAINST GWB BUT

ALLOW FOR FREE VERTICAL DEFLECTION MOVEMENT)

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

Frankfurt-Short-Bruza Associates,P.C.

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

C

B

A

D

C

B

A

54321

20190310

NDM

Jo int

B as e S an

A nto nio

JB

SA

Ke lly

A nn ex , T ex as

Te xa s A ir

Na tio na l G ua rd

9t h

FW

F-1

6 M iss ion Tr ain ing

C en ter (M

TC

C :\U sers\keisner\D ocum ents\90310_Arch_keisnerU

7YM

G .rvt

9/12/2024 10:43:20 AM

15 AUGUST 2024

PARTITION TYPES,

ANNOTATION SYMBOLS,

ABBREVIATIONS AND

ACCESSIBILITY MOUNTING

HEIGHTS

AE001

MJT

BKG

GMD

SCALE: NTS

PARTITION TYPESA5

SCALE: NTS

ARCHITECTURAL ABBREVIATIONS

SCALE: NTS

ARCHITECTURAL SYMBOLS LEGEND

C1

B1

1 Addendum 02 09/16/2024

SCALE: 6" = 1'-0"

TYP HEAD OF WALL DETAIL FOR

STC RATED PARTITIONSA1

0 1" 2" 4"

6" = 1'-0"

File details come from the government source that posted it. Updated .