AE401-ENLARGED PLANS AND DETAILS.pdf

PDF 315 KB Posted

Attached to
Construct Mission Training Center (MTC) Facility Federal contract opportunity
Solicitation number
W50S78-24-B-0001
Issued by
Department of the Army National Guard

About this file

This document is a federal solicitation for the construction of a 15,200 square foot Mission Training Center (MTC) facility for the Texas Air National Guard at Joint Base San Antonio (JBSA) Lackland Air Force Base. The contract will be a single firm fixed-price award with a period of performance of 540 calendar days. The project includes demolition, site work, utilities, masonry, roofing, HVAC, plumbing, electrical, communications, fire protection, and other construction requirements. The solicitation includes a base bid and eight options such as permeable pavement, landscaping, and specialty flooring. Several brand name items are specified for compatibility with existing systems. The project is set aside 100% for small businesses under NAICS code 236220. A site visit and pre-bid conference are scheduled, and all questions/RFIs must be submitted 5 days prior to bid opening. The Government will only distribute amendments via the SAM.gov website.

View the file

Other files for this federal contract opportunity

Other files attached to Construct Mission Training Center (MTC) Facility, newest first.
File Type Posted
MTC - ABSTRACT Posted 24 Sep 24.pdf PDF
C-301-REMOVAL PLAN.pdf PDF
S-002-TYPICAL DETAILS.pdf PDF
SF101-LOW ROOF FRAMING PLAN.pdf PDF
S-001-GENERAL NOTES.pdf PDF
New Utilities to East.pdf PDF
M-501 DETAILS.pdf PDF
AE501-SECTION DETAILS.pdf PDF
AE305-WALL SECTIONS.pdf PDF
SB102-SLAB AND WALL PLAN.pdf PDF
M-502 DETAILS.pdf PDF
AE001-PARTITION TYPES ANNOTATION SYMBOLS ABBREVIATIONS AND ACCESSIBILITY MOUNTING HEIGHTS.pdf PDF
AE603-DOOR DETAILS.pdf PDF
AE502-SECTION DETAILS.pdf PDF
AE101-FLOOR PLAN.pdf PDF
AE304-WALL SECTIONS.pdf PDF
C-401-PROPOSED PLAN.pdf PDF
C-602-DRAINAGE SCHEDULE AND DETAILS.pdf PDF
ES101-ELECTRICAL SITE PLAN.pdf PDF
AE503-SECTION DETAILS.pdf PDF
01 45 00 - Quality Control.pdf PDF
Amendment 0004 - 17 Aug 2024.pdf PDF
MTC RFI log 20240917.pdf PDF
W50S78-24-B-0001 - Mission Training Center Amendment 0003.pdf PDF
Attachment 14 - Geotechnical report-TX ANG Mission Training Center B-3.pdf PDF
MTC RFI log.pdf PDF
W50S7824B0001 - MTC - Amendment 02 - 20240829.pdf PDF
Pre-Proposal Site Visit Slides - MTC 27 Aug 24.pptx PPTX presentation
MFR Mission Training Center - 2nd Site Visit Pre-Propsal Conference Minutes.pdf PDF
Pre_Bid_Site Visit_MTC_Attendance_Sheet 27_Aug _2024.pdf PDF
W50S78-24-B-0001 - Mission Training Center Amendment 0001.pdf PDF
MTC RFI log.pdf PDF
2024.08.21_TX-ANG_149TH MISSION TRAINING CENTER_REVISED B3_VOL 1 SPECIFICATIONS.pdf PDF
ATTACHMENT 9 SPECS V1 ADDENDUM.pdf PDF
MFR Mission Training Center - Site Visit Pre-Propsal Conference Minutes.pdf PDF
Pre-Proposal Site Visit Slides - MTC 20 Aug 24 (002).pptx PPTX presentation
Pre_Bid_Site Visit_MTC_Attendance_Sheet 20_Aug _2024.pdf PDF
Attachment 6_Industrial Security.pdf PDF
Attachment 1_SOW.pdf PDF
Attachment 5_STRUCTURAL INTERIOR DESIGN.pdf PDF
Attachment 7_ACCESS AND STAGING SITE PLAN.pdf PDF
JA Nm Brand DDC Redacted.pdf PDF
JA Nm Brand Falcon Redacted.pdf PDF
2024.08.15_TX-ANG_149TH MISSION TRAINING CENTER_REVISED B3_VOL 2 SPECIFICATIONS.pdf PDF
2024.08.15_TX-ANG_149TH MISSION TRAINING CENTER_REVISED B3_VOL 1 SPECIFICATIONS.pdf PDF
JA Nm Brand Vindicator Sys Redacted.pdf PDF
W50S78-24-B-0001 - Mission Training Center Solicitation.pdf PDF
2024.08.15_TX-ANG_149TH MISSION TRAINING CENTER_REVISED B3_DRAWINGS.pdf PDF
JA Nm Brand Monaco Redacted.pdf PDF
JA Nm Brand Trane HVAC Redacted.pdf PDF
Show all 50

Construct Mission Training Center (MTC) Facility has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FA

C

U

C

D

E

AE402C1 D3

108A

MEN

A2

A2

A2

A2

A2

A2

A2

A4

B2

S3

8" 6'

-0

4' -1

1" 4'

-8

/4

1' -4

/4

6'

-7

/4

1/

4"

13'-3 7/8" 11 5/8"

1/

8"

'-6

/8

3' -1

/4

8'

-0

1/

4"

4'-10 7/8" 7'-7 3/4" 1'-9"

C

LR

5' -0

C

LR

3'

-1

C

LR

3' -1

5'-1 3/4"

A2

15 13

15 13

EQ

EQ

AE305

A4

C3

AE401

AE402B1 C3

8'-3 3/4"

A2

111A

112A

A2

A2

A2

A2

A2

WOMEN

JAN.

WAITING

B1

C1

1/

2" 6'

-2

/4

7' -0

/4

2'-5 3/8" 10'-11 5/8"

15 13 24

C

LR

3' -1

C

LR

5'

-0

1/

2" 8'

-8

4' -7

B2

B5

AE401

AE402

B3

B2

C

S3

B2

1'-6"

3/

4"

STEEL

STRUCTURE

5/8" GWB A4

1/2" CONTROL JOINT,

FILL WITH SOUND

MATERIAL

3"

9 1/4"

2 LAYERS

OF 5/8" GWB

C1C1

B1

B1 S3

B2

CONT FIRE

CAULK, BOTH

SIDES

FF

16" GA - 6" CFMF

DOUBLE JAMB STUDS

ALUMINUM

FRAMED

STOREFRONT

NOM 4" SPRAY

FOAM AIR

BARRIER

FLUID APPLIED

MEMBRANE AIR

BARRIER

1/2" EXT GYPSUM

SHEATHING

1/2" 9 1/8"

1/4" 2"

INSULATED

LAMINATED

GLAZING

BACKER ROD

AND SEALANT

(BOTH SIDES) 6" CFMF AT 16" OC

CONT 5/8" WOOD

BLOCKING

5/8" GWB

1/

2"

B3

STEEL COLUMN

CL

(MV1) MODULAR

BRICK VENEER

MASONRY ANCHORS

2" CAVITY WALL

INSULATION BOARD

5/ 8"

6" 6" 1/

2"

1/ 8"

3/

8" 6"

1/ 2"

2"

1/ 8"

7 1/8" 2" 1/2" 1'-0 3/4" 1/2" 2" 7 1/8"

CL

2'-8"

1/

8" 1'

-1 0"

1'-3 5/8" 1'-4 3/8"

CONT SAFING

MATERIAL

2" CAVITY WALL

INSULATION BOARD

1' -6

5/8" GYPSUM BOARD

STEEL STRUCTURE

B2

B2

1"

1"

3 5/8" METAL STUD

F

6" 8 3/8" 7 5/8"

3" 1/

2"

6"

3/ 8"

5/

8"

16 GA PREFIN BRAKE

METAL SILL FLASHING

PREFIN METAL IMWP

CORNER TRIM

(FWP1) 2"

INSULATED METAL

WALL PANELS

16 GA 3" HORIZ Z-

CHANNEL AT 48"

VERTICALLY

FLUID APPLIED

MEMBRANE AIR

BARRIER

1/2" EXT GYPSUM

SHEATHING

6" COLD FORMED

METAL FRAMING

NOM 4" SPRAY

FOAM AIR BARRIER

FF F

16" GA - 6" CFMF

DOUBLE JAMB STUDS

ALUMINUM

FRAMED

STOREFRONT

NOM 4" SPRAY

FOAM AIR

BARRIER

FLUID APPLIED

MEMBRANE AIR BARRIER

1/2" EXT GYPSUM

SHEATHING

1/2" 9 3/8"2"

INSULATED

LAMINATED

GLAZING

BACKER ROD

AND SEALANT

(BOTH SIDES)

6" CFMF AT 16" OC

CONT 5/8" WOOD

BLOCKING

5/8" GWB

1/

2"

B3

STEEL

COLUMN5/

8" 6" 6"

1/ 2"

1/

8"

3/ 8"

6" 1/

2" 3"

2"

2" 3" 1/2" 1'-0 3/4" 1/2" 3" 2"

FWP1 2" INSULATED

METAL WALL PANEL

PREFIN METAL WALL

PANEL TRIM

PREFIN BRAKE METAL

SILL FLASHING

3" 16 GA HORIZ

FURRING CHANNEL

AT 48" OC VERT

CL

PREFIN BRAKE

METAL FLASHING

CLOSURE

CL

1' -6

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

Frankfurt-Short-Bruza Associates,P.C.

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

C

B

A

D

C

B

A

54321

20190310

NDM

Jo int

B as e S an

A nto nio

JB

SA

Ke lly

A nn ex , T ex as

Te xa s A ir

Na tio na l G ua rd

9t h

FW

F-1

6 M iss ion Tr ain ing

C en ter (M

TC

2' 6'4'0

3/8" = 1'-0"

C :\U sers\keisner\D ocum ents\90310_Arch_keisnerU

7YM

G .rvt

9/16/2024 10:39:08 AM

15 AUGUST 2024

ENLARGED PLANS AND

DETAILS

AE401

MJT

BKG

GMD

GENERAL NOTES

A. ALL EXTERIOR PERIMETER MASONRY WAINSCOT

BASE COURSE DIMENSIONS ARE NOMINAL AND THE

CONTRACTOR SHALL BE RESPONSIBLE FOR

COORDINATING ADJUSTMENTS AT OPENINGS TO

ACCOUNT FOR DOOR FRAMES.

B. ALL INTERIOR DIMENSIONS ARE FROM FACE OF STUD

TO FACE OF STUD OR FACE OF CMU OR CONCRETE

AS INDICATED - UNLESS NOTED OTHERWISE.

C. GFGI = GOVERNMENT FURNISHED, GOVERNMENT

INSTALLED.

SHEET KEYNOTES

1. MECHANICAL EQUIPMENT.

2. ALUM ROOF ACCESS LADDER.

3. ROOF HATCH ABOVE.

4. FLOOR CLEANOUT.

5. FLOOR DRAIN.

6. SEMI-RECESSED WASTE RECEPTACLE. (WR)

7. WATER CLOSET.

8. ADA WATER CLOSET.

9. URINAL.

10. ADA URINAL.

11. 18" DEEP URINAL SCREEN

12. DRINKING FOUNTAINS.

13. TOILET TISSUE DISPENSER. (TTD)

14. TOILET COMPARTMENTS.

15. SEAT COVER DISPENSER. (SCD)

16. 36" GRAB BAR. (GB)

17. 42"GRAB BAR. (GB)

18. SCHEDULED SINK AND FAUCET.

19. 24"x48" MIRROR. (MG)

20. SOAP DISPENSER, GFGI

21. MOP SINK.

22. REFRIGERATOR.

23. 36" NOM - 4 HOOK MOP AND BROOM HOLDER. (MH)

24. SANITARY NAPKIN DISPOSER. (SND)

25. ELECTRICAL EQUIPMENT.

26. SURFACE MOUNTED SOAP DISPENSER. (SD)

27. CELL PHONE LOCKER

28. 18" GRAB BAR, (GB)

29. PAPER TOWEL DISPENSER, GFGI

SCALE: 3/8" = 1'-0"

ENLARGED PLAN - MENS 108C1

SCALE: 3/8" = 1'-0"

ENLARGED PLAN - WOMEN 112C2

N

SCALE: 1 1/2" = 1'-0"

DETAILC3

6" 1'-6"1'0

1 1/2" = 1'-0"

SCALE: 1 1/2" = 1'-0"

DETAILB5

SCALE: 3" = 1'-0"

PILASTER DETAIL @ BRICKA1

3" 9"6"0

3" = 1'-0"

SCALE: 1 1/2" = 1'-0"

DETAILD4

SCALE: 3" = 1'-0"

PILASTER DETAIL @ FABRICATED WALL PANELA3

LEGEND

GRAPHIC VISUAL PLANE OF

CONT AIR BARRIER WHERE

SHOWN ALL SHEETS

NOTE: REFERENCE SPECIFICATION SECTIONS

07 05 23 AND 07 27 10.00 10 FOR DESCRIPTION

OF DESCRIPTION OF AIR BARRIER SYSTEM

OUTLINE OF SECURE

PERIMETER 1 WALL

1 Addendum 02 09/16/2024

File details come from the government source that posted it. Updated .