This document appears to be a detailed set of construction drawings and specifications for a Mission Training Center (MTC) facility for the Texas Air National Guard at Joint Base San Antonio Lackland. The key details are:

The project is for the construction of a 15,200 square foot FTU 4-ship F-16 MTC facility, including demolition, site work, utilities, structural steel, roofing, mechanical, electrical, and other related work. The contract will be a single firm fixed-price award with a 540 calendar day period of performance. The solicitation includes a base bid and 8 options such as permeable pavement, landscaping, specialty flooring, and additional equipment. Brand name items are specified for compatibility with existing systems. The project is 100% set aside for small businesses under NAICS code 236220 with a magnitude between $10-25 million. A site visit and pre-bid conference will be held, and all questions/RFIs must be submitted 5 days prior to bid opening.

View the file

Other files for this federal contract opportunity

Other files attached to Construct Mission Training Center (MTC) Facility, newest first.
File Type Posted
MTC - ABSTRACT Posted 24 Sep 24.pdf PDF
C-301-REMOVAL PLAN.pdf PDF
S-002-TYPICAL DETAILS.pdf PDF
SF101-LOW ROOF FRAMING PLAN.pdf PDF
S-001-GENERAL NOTES.pdf PDF
New Utilities to East.pdf PDF
M-501 DETAILS.pdf PDF
AE305-WALL SECTIONS.pdf PDF
C-401-PROPOSED PLAN.pdf PDF
C-602-DRAINAGE SCHEDULE AND DETAILS.pdf PDF
ES101-ELECTRICAL SITE PLAN.pdf PDF
AE401-ENLARGED PLANS AND DETAILS.pdf PDF
AE503-SECTION DETAILS.pdf PDF
01 45 00 - Quality Control.pdf PDF
Amendment 0004 - 17 Aug 2024.pdf PDF
MTC RFI log 20240917.pdf PDF
C-201-STORMWATER POLLUTION PREVENTION PLAN.pdf PDF
C-601-UTILITY PLAN.pdf PDF
SF102-HIGH ROOF FRAMING PLAN.pdf PDF
G-003-CODE AND LIFE SAFETY PLAN.pdf PDF
M-702 SCHEDULES.pdf PDF
M-701 SCHEDULES.pdf PDF
AE601-ROOM FINISH SCHEDULE AND GLAZING TYPES AND MISC DETAILS.pdf PDF
AE303-WALL SECTIONS.pdf PDF
23 05 48.19 - SEISMIC BRACING FOR HVAC.pdf PDF
23 05 48.00 40 - VIBRATION CONTROLS FOR HAC PIPING AND EQUIPMENT.pdf PDF
11 94 10 - Rooftop Fall Protection Anchors.pdf PDF
W50S78-24-B-0001 - Mission Training Center Amendment 0003.pdf PDF
Attachment 14 - Geotechnical report-TX ANG Mission Training Center B-3.pdf PDF
MTC RFI log.pdf PDF
W50S7824B0001 - MTC - Amendment 02 - 20240829.pdf PDF
Pre-Proposal Site Visit Slides - MTC 27 Aug 24.pptx PPTX presentation
MFR Mission Training Center - 2nd Site Visit Pre-Propsal Conference Minutes.pdf PDF
Pre_Bid_Site Visit_MTC_Attendance_Sheet 27_Aug _2024.pdf PDF
MTC RFI log.pdf PDF
2024.08.21_TX-ANG_149TH MISSION TRAINING CENTER_REVISED B3_VOL 1 SPECIFICATIONS.pdf PDF
ATTACHMENT 9 SPECS V1 ADDENDUM.pdf PDF
Pre-Proposal Site Visit Slides - MTC 20 Aug 24 (002).pptx PPTX presentation
Pre_Bid_Site Visit_MTC_Attendance_Sheet 20_Aug _2024.pdf PDF
Attachment 6_Industrial Security.pdf PDF
Attachment 5_STRUCTURAL INTERIOR DESIGN.pdf PDF
Attachment 7_ACCESS AND STAGING SITE PLAN.pdf PDF
JA Nm Brand DDC Redacted.pdf PDF
JA Nm Brand Falcon Redacted.pdf PDF
2024.08.15_TX-ANG_149TH MISSION TRAINING CENTER_REVISED B3_VOL 1 SPECIFICATIONS.pdf PDF
JA Nm Brand Vindicator Sys Redacted.pdf PDF
W50S78-24-B-0001 - Mission Training Center Solicitation.pdf PDF
2024.08.15_TX-ANG_149TH MISSION TRAINING CENTER_REVISED B3_DRAWINGS.pdf PDF
JA Nm Brand Monaco Redacted.pdf PDF
JA Nm Brand Trane HVAC Redacted.pdf PDF
Show all 50

Construct Mission Training Center (MTC) Facility has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

3" 16 GA HORIZ FURRING

CHANNEL AT 48" OC

VERTICALLY

(FWP1) 2" INSULATED

METAL WALL PANEL

BENT STEEL PLATE(S)

3 1/2"X3 1/2" CONT

16 GA CLIP

1/2" EXT GYPSUM

SHEATHING

FLUID APPLIED

MEMBRANE AIR

BARRIER

2"X2" CONT 16 GA CLIP

FOUR - 2" LAYERS

ROOF INSULATION

1/2" PROT BOARD

16 GA CFMF CONT

PNTD BRAKE METAL

CLOSURE

STEEL STRUCTURE

16 GA - 6" CFMF AT

16" OC

(SSSR1) PREFIN HIGH

EAVE CLOSURE AND

ZEE FLASHING

4" X 12" - 12 GA CFMF

DEFL CLIPS AT 16" OC

MIN.

STEEL DECK

SELF-ADHERED

UNDERLAYMENT

(SSSR1) STEEL

STANDING SEAM

ROOFING

SELF-ADHERED

UNDERLAYMENT

VISUAL PLANE OF

AIR BARRIER

6"

CONT SELF-ADHERED

UNDERLAYMENT

FLEXIBLE LAPPED SEAL

CLOSURE

1'-5 7/8" 2"

1" / 1'-0"FALL PROTECTION

SYSTEM

1" D

EF

L.

PERFORATED RF SHIELDING/

FOIL MEMBRANE

REFER AE520 FOR TYPICAL RF

SHIELDING/FOIL NOTES AND

DETAILS

NOM 4" SPRAY FOAM AIR

BARRIER - OPEN CELL

(R-17 MIN.) WITH ASTM E84

COMPLIANT FIRE RETARDANT

SURFACE FILM

5/8” GYSUM WALL BOARD

(GWB) 2 LAYERS

HIGH EAVE (LOW) DB

123' - 0"

16 GA - 3" HORIZ

FURRING CHANNELS

AT 48" OC VERTICALLY

(FWP1) 2" INSULATED

METAL WALL PANEL

2"X2" CONT 16 GA CLIP

BENT STEEL PLATE(S)

FOUR - 2" LAYERS

ROOF INSULATION

1/2" PROT BOARD

SELF-ADHERED

UNDERLAYMENT

3 1/2"X3 1/2" CONT 16

GA CLIP

16 GA CFMF CONT

PNTD BRAKE METAL

CLOSURE

STEEL STRUCTURE

16 GA - 6" CFMF AT 16" OC1/2" EXT GYPSUM

SHEATHING

4" X 12" - 12 GA CFMF

DEFL CLIPS AT 16" OC

MIN.

STEEL DECK

FLUID APPLIED

MEMBRANE AIR

BARRIER

CONT SELF-ADHERED

UNDERLAYMENT

FLEXIBLE LAPPED SEAL

CLOSURE

(SSSR1) STEEL

STANDING SEAM

ROOFING

VISUAL PLANE OF AIR

BARRIER

8X8 PREFIN METAL

GUTTER AND 6X6

DOWNSPOUT

G

2" 1'-5 7/8"

1" / 1'-0"

FALL PROTECTION

SYSTEM

7/ 8"

D

EF

L.

115'-0" AT LOW EAVE

(LOW) DB

(SSSR1) PREFIN LOW

EAVE CLOSURE

FLASHING

GUTTER STRAP

ANCHOR(S)

SNOW GUARD SYSTEM

PERFORATED RF SHIELDING/

FOIL MEMBRANE

REFER AE520 FOR TYPICAL RF

SHIELDING/FOIL NOTES AND

DETAILS

NOM 4" SPRAY FOAM AIR

BARRIER - OPEN CELL

(R-17 MIN.) WITH ASTM E84

COMPLIANT FIRE RETARDANT

SURFACE FILM

5/8” GYSUM WALL BOARD

(GWB) 2 LAYERS

FLUID APPLIED

MEMBRANE AIR

BARRIER

PREFIN BRAKE METAL

SILL FLASHING

16 GA - 3" HORIZ

FURRING CHANNEL AT

48" OC VERTICALLY

ROWLOCK COURSE

(MV1) MODULAR BRICK

VENEER

MASONRY ANCHORS

2" CAVITY WALL

INSULATION BOARD

FLUID APPLIED

MEMBRANE AIR

BARRIER

16 GA - 6" CFMF

AT 16" OC

1/2" EXT GYPSUM

SHEATHING

EQEQ

9 5/8"

METAL WALL PANEL

TRIM

103'-0"

T.O. BRICK

(FWP1) 2" INSULATED

METAL WALL PANEL

VISUAL PLANE OF

AIR BARRIER

112'-0" AT SIM

PERFORATED RF

SHIELDING/ FOIL

MEMBRANE

REFER AE520 FOR

TYPICAL RF

SHIELDING/FOIL

NOTES AND DETAILS

NOM 4" SPRAY FOAM

AIR BARRIER - OPEN

CELL (R-17 MIN.) WITH

ASTM E84 COMPLIANT

FIRE RETARDANT

SURFACE FILM

5/8” GYSUM WALL

BOARD (GWB) 2

LAYERS

GROUND FLOOR

100' - 0"

A

(MV1) MODULAR BRICK

VENEER

MORTAR CONTROL

MESH

FLUID APPLIED

MEMBRANE AIR

BARRIER

2" CAVITY WALL

INSULATION BOARD

CAVITY WEEPS

16 GA - 6" CFMF AT

16" OC

CONC FLOOR SLAB

CONCRETE

FOUNDATION

1/2" EXT GYPSUM

SHEATHING

SOLID GROUT FILL

2' - 0"

MASONRY ANCHORS

9 5/8"6"8 3/8"

SELF-ADHERED

THROUGH WALL

FLASHING

2" CAVITY WALL

INSULATION BOARD

VISUAL PLANE OF

AIR BARRIER

SCHEDULED BASE

1' -4

PERFORATED RF SHIELDING/

FOIL MEMBRANE

REFER AE520 FOR TYPICAL RF

SHIELDING/FOIL NOTES AND

DETAILS

NOM 4" SPRAY FOAM

AIR BARRIER - OPEN

CELL (R-17 MIN.) WITH

ASTM E84 COMPLIANT

FIRE RETARDANT

SURFACE FILM

5/8” GYSUM WALL BOARD

(GWB) 2 LAYERS

3" 16 GA HORIZ

FURRING CHANNEL AT

48" OC VERTICALLY

(FWP1) 2" INSULATED

METAL WALL PANEL

16 GA - 6" CFMF AT

16" OC

1/2" PROT BOARD

FOUR - 2" LAYERS

ROOF INSULATION

STEEL DECK

STEEL STRUCTURE

FLUID APPLIED

MEMBRANE AIR

BARRIER

PREFIN RAKE

FLASHING

(SSSR1) STEEL

STANDING SEAM

ROOFING

PREFIN METAL WALL

PANEL TRIM

1/2" EXT GYPSUM

SHEATHING

SELF-ADHERED

UNDERLAYMENT

2" 3" 1/2" 6" 8 3/8"

CONT SAFING

INFILL

CONT SAFING INFILL

CONT OVERLAPPING

FLEXIBLE SPRAY (BOTH

SIDES)

CONT FIRE CAULK

(BOTH SIDES)

CONT 16 GA - 3 1/2" X 1 1/2"

CFMF CLIP ANGLE (BOTH

SIDES)

PERFORATED RF SHIELDING/

FOIL MEMBRANE

REFER AE520 FOR TYPICAL RF

SHIELDING/FOIL NOTES AND

DETAILS

NOM 4" SPRAY FOAM AIR

BARRIER - OPEN CELL

(R-17 MIN.) WITH ASTM E84

COMPLIANT FIRE RETARDANT

SURFACE FILM

5/8” GYSUM WALL BOARD

(GWB) 2 LAYERS

5801 Broadway Extension, Suite 500 Oklahoma City, OK 73118-7436

405.840.2931 | fsb-ae.com

Frankfurt-Short-Bruza Associates,P.C.

D

SHEET NUMBER:

ISSUE DATE:

SHEET TITLE:

PROJECT NUMBER:

PROJECT INFORMATION:

REVISION HISTORY:

DATEDESCRIPTION

REVIEWED BY:

DRAWN BY:

DESIGNED BY:

PROJECT MANAGER:

C

B

A

D

C

B

A

54321

20190310

NDM

Jo int

B as e S an

A nto nio

JB

SA

Ke lly

A nn ex , T ex as

Te xa s A ir

Na tio na l G ua rd

9t h

FW

F-1

6 M iss ion Tr ain ing

C en ter (M

TC

3" 9"6"0

3" = 1'-0"

C :\U sers\keisner\D ocum ents\90310_Arch_keisnerU

7YM

G .rvt

9/16/2024 10:23:35 AM

15 AUGUST 2024

SECTION DETAILS

AE501

MJT

BKG

GMD

SCALE: 3" = 1'-0"

EAVE (HIGH) DETAILC3SCALE: 3" = 1'-0"

EAVE (LOW) DETAILC1

SCALE: 3" = 1'-0"

EXTERIOR WALL TRANSITION DETAILC4

SCALE: 3" = 1'-0"

BASE/FOUNDATION DETAILA3

LEGEND GRAPHIC VISUAL PLANE OF CONT AIR

BARRIER WHERE SHOWN ALL SHEETS

8 3/8"

TO GRIDLINE

SCALE: 3" = 1'-0"

LOW ROOF TO HI-BAYA1

NOTE: REFERENCE SPECIFICATION SECTIONS

07 05 23 AND 07 27 10.00 10 FOR DESCRIPTION

OF AIR BARRIER SYSTEM

1 Addendum 02 09/16/2024