S02 - ATT 7 - 581-22-700 - 100 Drawings Part-5 of 24.pdf

PDF 19 MB Posted

Attached to
EHRM Huntington VAMC 581-22-700 Construct Infrastructure Upgrades
Solicitation number
36C77626R0025
Issued by

About this file

This document is a 100% Construction Documents set of architectural and engineering plans for the EHRM Infrastructure Upgrades project at the VA Medical Center in Huntington, West Virginia. The plans are prepared by SPEES Design Build and dated September 3, 2025.

The construction documents detail phased renovation work across multiple buildings (Buildings 02, 03, 04, 05, 06, 07, 08, 09, 20, 23R, 25, 28, 34, and temporary trailers TR1-TR5). Phase 1 construction includes completion of work in designated areas with associated data drops, with sections phased to allow room closures and coordination with the VA. The plans include detailed floor plans, reflected ceiling plans, demolition plans, exterior elevations, building sections, roof plans, mechanical shaft details, and exterior wall details for towers and various building levels. Key construction features include fire-rated walls and doors (1-hour and 2-hour rated), ICRA (Infection Control Risk Assessment) Class II and III barrier requirements, specific room finishes with paint specifications, and comprehensive door schedules with hardware specifications. The project incorporates new construction footprints, preparation areas, temporary exhaust relocation, expansion joints, and specialized wall assemblies including metal stud framing with insulation, gypsum board, plywood sheathing, rigid insulation, and brick veneer systems. Room finish schedules specify materials for floors, bases, walls, and ceilings across all project areas, with data center-specific wall construction details and fire-rated assembly requirements.

View the file

Other files

File Type Posted
S06 - 36C77626R0025 0008.pdf PDF
S06 - Amendment 0008 - ATT 7 - 02EP100B - ELECTRICAL 20260413.pdf PDF
S06 - Amendment 0008 - ATT 11 - Burn Permit.pdf PDF
S06 - Amendment 0008 - ATT 10 - 260508 - Sheet AD103-1B Data Center Phase 1B Demo Roof update.pdf PDF
S06 - Amendment 0008 - ATT 9 - 260508 - Sheet AD101-1B Data Center Phase 1B Demo Floor Plan update.pdf PDF
S06 - Amendment 0008 - ATT 1 - TechQuestionsVAresponses Final Set - Huntington EHRM IU.pdf PDF
S06 - Amendment 0008 - ATT 14 - Energized Electrical Work Permit.pdf PDF
S06 - Amendment 0008 - ATT 5 - ELECTRICAL 2026.04.13.pdf PDF
S06 - Amendment 0008 - ATT 6 - 01WEP100G - ELECTRICAL 20260413.pdf PDF
S06 - Amendment 0008 - ATT 3 - Civil OSP Redesign-signed.pdf PDF
S06 - Amendment 0008 - ATT 12 - Environmental Report Huntington WV.pdf PDF
S06 - Amendment 0008 - ATT 8 - 260508 - Sheet 01S-AE452 TR Tower 4 Wall sections update.pdf PDF
S06 - Amendment 0008 - ATT 13 - Hot Tapping Permit.pdf PDF
S06 - Amendment 0008 - ATT 2 - UPDATED SHEETS.pdf PDF
S06 - Amendment 0008 - ATT 4 - Structural Set 04-21-2026.pdf PDF
S06 - 36C77626R0025 0007.pdf PDF
S06 - Amendment 0007 - ATT 1 - TechQuestionsVAresponses Partial 4 - Huntington EHRM IU.pdf PDF
S06 - Amendment 0007 - ATT 3 - Lift Planning.pdf PDF
S06 - Amendment 0007 - ATT 2 - Geotechnical Report.pdf PDF
S06 - Amendment 0007 - ATT 5 - Appendix A - PFC FPT.pdf PDF
S06 - Amendment 0007 - ATT 4 - 01 00 00 - GENERAL REQUIREMENTS_A1.pdf PDF
S06 - Amendment 0007 - ATT 6 - Crane lift Info.pdf PDF
S06 - 36C77626R0025 0006.pdf PDF
S06 - Amendment 0006 - ATT 1 - TechQuestionsVAresponses Partial 3 - Huntington EHRM IU.pdf PDF
S06 - 36C77626R0025 0005.pdf PDF
S06 - Amendment 0004 - ATT 2 - FAR 52.222-90 ADDRESSING DEI DISCRIMINATION BY FEDERAL CONTRACTORS - APR 2026.pdf PDF
S06 - Amendment 0004 - ATT 1 - TechQuestionsVAresponses Partial 2 - Huntington EHRM IU.pdf PDF
S06 - 36C77626R0025 0004.pdf PDF
S06 - Amendment 0003 - ATT 2 - TechQuestionsVAresponses Partial - Huntington EHRM IU.pdf PDF
S06 - 36C77626R0025 0003.pdf PDF
S06 - 36C77626R0025 0002.pdf PDF
S06 - Amendment 0001 - ATT 1 - Site Visit In-Sheet - Huntington EHRM IU.pdf PDF
S06 - 36C77626R0025 0001.pdf PDF
S02 - ATT 28 - 581-22-700 - FLS Compliance Letter.pdf PDF
S02 - ATT 3 - 581-22-700 - 100 Drawings Part-1 of 24.pdf PDF
S02 - ATT 15 - 581-22-700 - 100 Drawings Part-13 of 24.pdf PDF
S02 - ATT 30 - 581-22-700 - 100 Commissioning Plan.pdf PDF
S02 - ATT 20 - 581-22-700 - 100 Drawings Part-18 of 24.pdf PDF
S02 - ATT 24 - 581-22-700 - 100 Drawings Part-22 of 24.pdf PDF
S02 - ATT 1 - 581-22-700 - 100 Specifications Part-1 of 2.pdf PDF
S02 - ATT 10 - 581-22-700 - 100 Drawings Part-8 of 24.pdf PDF
S02 - ATT 12 - 581-22-700 - 100 Drawings Part-10 of 24.pdf PDF
S02 - ATT 23 - 581-22-700 - 100 Drawings Part-21 of 24.pdf PDF
S02 - ATT 31 - 581-22-700 - Topographic Survey TR Tower 3.pdf PDF
S02 - ATT 25 - 581-22-700 - 100 Drawings Part-23 of 24.pdf PDF
S02 - ATT 16 - 581-22-700 - 100 Drawings Part-14 of 24.pdf PDF
S02 - ATT 21 - 581-22-700 - 100 Drawings Part-19 of 24.pdf PDF
S02 - ATT 34 - HEFP SEP Design Alerts 1-9 and 11-16.pdf PDF
S02 - ATT 29 - 581-22-700 - Geotechnical Report - W24044 - VA Duct Bank 11.21.24.pdf PDF
S02 - ATT 14 - 581-22-700 - 100 Drawings Part-12 of 24.pdf PDF
Show 40 more

Latest 50 of 68 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

360°

C

C

SHOWN AREA

PROJECT

NORTH

TO DEMOLISH

EXISTING DOOR TO REMAIN

EXISTING DOOR TO DEMOLISH

NEW DOOR

NEW LIGHTS (SEE ELECTRICAL DETAILS)

( + ) PRESSURE

CONSTRUCTION ZONE, (--) PRESSURE

TEMPORARY ICRA BARRIER

TEMPORARY ICRA DOOR

CONSTRUCTION TACKY MAT

HEPA EQUIPPED EXHAUST

A7 A6

A5

T3-S1

T3-SA

T3-SB

T3-S2

TEMPORARY LOCATION OF EXHAUST.

MOVE INSIDE NEW TR ONCE FEASIBLE.

FOOTPRINT OF NEW

CONSTRUCTION.

PREPARE AREA FOR

NEW CONSTRUCTION.

DEMO (E) VENEER BRICK

(WHERE OCCUR) THE

ENTIRE WIDTH AND

HEIGHT OF NEW TOWER

CARPENTRY

SHOP

1444 SF

M&O FOREMAN

BD102C

183 SF

STORAGE

BD102D

87 SF

PAINT

BOOTH

BD102B

108 SF

A7 A6

T3-S1

T3-SA

T3-SB

T3-S2

FOOTPRINT OF NEW

CONSTRUCTION.

CARPENTRY

SHOP

BD102

1444 SF

A7 A6

T3-S1

175 SF

TR TOWER 3

T3-00B

02A-100Gc

02A-100Gc

02A-100Gb

NEW

FLOORING

EXISTING

FLOORING

T3-SA

T3-SB

2'-6"x1'-4"

DUCT CHASE

EXPANSION JOINT

AT FLOOR

CARPENTRY

SHOP

1444 SF

M&O FOREMAN

BD102C

183 SF

T3-S2

EXPANSION JOINT

AT WALL

2' - 6"

02a

T3-00B

IN-03.01-18

02A-100Gb

1' - 0"

11' - 8 5/8"

1' - 6"

3"

/2

02A-512

02A-501

1'

/2

1'

13' - 7 5/8"

2" 5"

C1 02c

02c

C1

02a

02b

C1

3 1/8"

IN-01.02

04a

C1

A7 A6

T3-S1

CARPENTRY

SHOP

1444 SF

02A-100Gc

02A-100Gc

T3-SA

T3-SB

T3-S2

175 SF

TR TOWER 3

T3-00B

3' - 1"

AFF

GWB SOFFIT

7' - 6"

3' - 1"

2' - 2"

2' - 3"

EXPOSED

TR TOWER 3

01W

0223R 01S

NFPA

TABLE 7.2.1.1 FIRE RESISTANCE RATING FOR TYPE I - 332 (HR)

COLUMNS

SUPPORTING MORE THAN ONE FLOOR 3 HOUR

SUPPORTING ONE FLOOR / ROOF ONLY 2 HOUR

BEAMS

SUPPORTING ONE FLOOR / ROOF ONLY 2 HOUR

FLOOR/CEILING ASSEMBLIES 2 HOUR

ROOF/CEILING ASSEMBLIES 1 1/2 HOUR

INTERIOR/EXTERIOR NONBEARING WALLS 0 HOUR

FIRE RATED REQUIREMENTS

FIRE RATING SCHEDULE

UL

REFERENCE

COLUMNS SUPPORTING ONE FLOOR

HOURLY

RATINGTYPE ELEMENT

I 2 HR UL X854

I COLUMNS SUPPORTING MORE

THAN ONE FLOOR

3 HR UL X854

COLUMNS SUPPORTING ROOFI 2 HR UL X854

FLOOR DECKSI 2 HR UL D779

FLOOR SUPPORTSI 2 HR UL P732

ROOF DECKSI 1 1/2 HR UL P732

ROOF SUPPORTSI 2 HR UL N732

FIRE RATED SCHEDULE

1. ALL PRODUCTS AND FINISHES SHALL MATCH EXISTING OR

ADJACENT EXISTING UNLESS OTHERWISE NOTED.

2. PATCH AND REPAIR WALLS, FLOORS AND CEILINGS

WHERE MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS

ARE DEMOLISHED.

3. PROTECT FINISHES IN ROOMS ADJACENT TO THE AREA OF

WORK AND PARTS THAT ARE NOT INCLUDED IN THE

SCOPE.

4. CONTRACTOR SHALL LEAVE FIRE RATING STAMP

UNPAINTED AND VISIBLE ON THE NEW INSTALLED FRT

PLYWOOD. SEE DETAIL 5/AE401.

5. REFER TO SHEET AS101 FOR ICRA REQUIREMENTS AND

DETAILS.

6. PATCH AND REPAIR CEILING, WALLS AND FLOORS AS

REQUIRED WHERE ICRA BARRIERS WILL BE CONSTRUCTED

AND REMOVED.

7. REFER TO SHEET A-602 FOR DOOR SCHEDULE.

7 INSTALL TEMPORARY 1 HR CONSTRUCTION ICRA BARRIER TO

SEPARATE CONSTRUCTION AREA FROM OCCUPIED SPACE.

REFERENCE DETAIL 3/AS101

8 INSTALL FIRE RESISTANT TEMPORARY SELF-CLOSING DOOR,

SOLID CORE WOOD IN STEEL FRAME, PAINTED, AT OPENING

AND MATCH RATING OF ICRA BARRIER, TYPICAL.

9 PLACE TACKY MATS AT ENTRANCE AND EXIT OF

CONSTRUCTION AREA, MINIMUM SIZE 24"x36", TYPICAL.

1 DEMOLISH PORTION OF EXISTING WALL. PREPARE FOR NEW

DOOR/FRAME.

2 INSTALL NEW DOOR/FRAME.

3 CONSTRUCT NEW FLOOR.

4 APPLY ANTI-STATIC COATING TO EXPOSED FLOOR. PROVIDE

VINYL REDUCER STRIP AT EXISTING FLOORING TRANSITION.

5 INSTALL NEW RESILIENT RUBBER BASE AT ROOM PERIMETER

WITH SEALANT AT THE BOTTOM.

6 THIS SPACE WILL BE UTILIZED FOR NEW

TELECOMMUNICATION ENCLOSURE. PROVIDE NEW FRT

PLYWOOD OVER WALLS PER DETAIL 3/AE401, TYPICAL.

GENERAL NOTES

KEY PLAN

KEY NOTES (THIS SHEET ONLY)

LEGEND

PROJECT

NORTH

PROJECT

NORTH

PROJECT

NORTH

PROJECT

NORTH

1/4" = 1'-0"

LEVEL 00B - TR TOWER 3 - DEMO FLOOR PLAN

1/4" = 1'-0"

LEVEL 00B - TR TOWER 3 - DEMO RCP

1/4" = 1'-0"

RM T3-00B - FLOOR PLAN

1/4" = 1'-0"

RM T3-00B - RCP

ICRA KEYNOTES

ICRA CLASS III LEGEND

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0 /2

:2

:5 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n E

H R

M /B

L D

G

T

R T

O W

E R

.r v t

02A-100B

BUILDING 02 - LEVEL 00B - DEMO, FLOOR

PLANS & RCPS

MA SR/RB

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

Revisions: Date:

09/03/20259/3/2025 126 OF 693

A7 A6

A5 A4

A3

A8

A11 A10

A9

A2 A1

164 SF

LOUNGE

GD114E

101 SF

TOILET

GD114D

102 SF

LAUNDRY

PLANT

FOREMAN

GD114C

88 SF

UNIFORM STOR

GD114B

151 SF

SEWING

GD114A

3268 SF

LAUNDRY

GD114

242 SF

BOILER ROOM

GD114G

249 SF

STORAGE

GD114F

669 SF

SOILED

GD113

106 SF

CPU ROOM

GD112

270 SF

LOUNGE/BREAK

226 SF

PT. CLOTH

GD111

201 SF

LOCKERS

G112D

26 SF

SHR

GD112B

109 SF

MEN

GD112A

181 SF

FPMS

99 SF

GD110A

234 SF

GD110 49 SF

ELEV

F8

213 SF

FREEZER

271 SF

FREEZER

136 SF

FRIDGE

155 SF

FREEZER

387 SF

SALAD PREP

GD109

484 SF

MECH

105 SF

GD105

301 SF

GD104

158 SF

GD106

99 SF

IRM

GD108

198 SF

IRM

GD100

143 SF

GD103

222 SF

GD102

275 SF

GD101

130 SF

GD107

BUILDING 02

PHASE 1:

CONTRACTOR TO COMPLETE THE WORK OF THIS TR AND ASSOCIATED DATA

DROPS. COMPLETE ONE SECTION AT A TIME AS DIRECTED TO COR.

BUILDING 02

SECTION 1A:

CONTRACTOR TO COORDINATE WITH VA FOR ROOM CLOSURES AND

AVAILABILITY TO COMPLETE DATA WIRING IN THIS AREA.

BUILDING 02

SECTION 1B:

CONTRACTOR TO COORDINATE WITH VA FOR ROOM CLOSURES

AND AVAILABILITY TO COMPLETE DATA WIRING IN THIS AREA.

BLDG. 02

BLDG. 01

TR TOWER 3

T3-00G

184 SF

BLDG. 01S

FEC

NEW SEMI-RECESSED FEC, TO MATCH

OR EXCEED EXISTING EXTINGUISHER IN

ABC RATING AND SIZE. SEE DET 4/A-604.

TR TOWER 3

01W

0223R 01S

01A

TR

ICRA PHASING LINE

ICRA CLASS III

ICRA CLASS IV

ICRA CLASS II

FIRE EXTINGUISHER CABINETFEC

FIRE EXTINGUISHERFE

BUILDING BOUNDARY LINE

2 HR FIRE RATED WALL

1 HR FIRE RATED WALL

SMOKE RATED WALL

SHOWN AREA

PROJECT

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0

/2

:5

:1 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n E

H R

M /B

L D

G

G R

O U

N D

F L O

O R

.r v t

02AS100G

BUILDING 02 - LEVEL 00G - PHASING PLAN

MA RB

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

KEY PLAN

LEGEND

1/16" = 1'-0"

BUILDING 02 - LEVEL 00G - PHASING PLAN

PROJECT

NORTH

09/03/20259/3/2025 127 OF 693

DN

WAP

DN

W

X

SHOWN AREA

PROJECT

NORTH

A7A6

T3-S1

A8 A9

TEMPORARY LOCATION OF

EXHAUST. MOVE INSIDE

NEW TR ONCE FEASIBLE.

T3-SA

T3-SB

T3-S2

FOOTPRINT OF NEW

CONSTRUCTION.

PREPARE AREA FOR

NEW CONSTRUCTION.

DEMO (E) VENEER BRICK

(WHERE OCCUR) THE

ENTIRE WIDTH AND

HEIGHT OF NEW TOWER

E Q

E Q

'-0

M

IN

/8

9'

/4

9'

/4

'-0

M

IN

/8

LAUNDRY

GD114

3268 SF

STORAGE

GD114F

249 SF

BOILER ROOM

GD114G

242 SF

A7A6

T3-S1

A8 A9

T3-SA

T3-SB

T3-S2

FOOTPRINT OF NEW

CONSTRUCTION.

LAUNDRY

GD114

3268 SF

STORAGE

GD114F

249 SF

BOILER ROOM

GD114G

242 SF

A7A6

T3-S1

A8 A9

LAUNDRY

GD114

3268 SF

184 SF

TR TOWER 3

T3-00G

02A-100Gc

02A-100Gc

02A-100Gb

02A-100Gb

E1C

E1C

CLEARANCE

11' - 2 1/2"

T3-SA

T3-SB

T3-S2

T3-00G

IN-03.01-19

02A-100Gb

6"

6"

1/ 8"

/2

4" 6"

3/

8"

04a

02a

SEAL WINDOW DURING

CONSTRUCTION

SEAL WINDOW DURING

CONSTRUCTION

14' - 0 3/4"

19' - 1"

2'

3' - 10"

NEW

FLOORING

EXISTING

FLOORING

EXPANSION

JOINT COVER

02A-512

02A-501

/8

3"

3"

E1C

02a

02c

2 3/8"

IN-01.02

A7 A6

T3-S1

A8 A9

EXPOSED

LAUNDRY

GD114

3268 SF

184 SF

TR TOWER 3

T3-00G

02A-100Gc

02A-100Gc

T3-SA

T3-SB

3' - 1"

T3-S2

3' - 1"

1' - 9"

1' - 9"

EXPOSED

TR TOWER 3

01W

0223R 01S

01A

TO DEMOLISH

EXISTING DOOR TO REMAIN

EXISTING DOOR TO DEMOLISH

NEW DOOR

NEW LIGHTS (SEE ELECTRICAL DETAILS)

( + ) PRESSURE

CONSTRUCTION ZONE, (--) PRESSURE

TEMPORARY ICRA BARRIER

TEMPORARY ICRA DOOR

CONSTRUCTION TACKY MAT

HEPA EQUIPPED EXHAUST

NFPA

TABLE 7.2.1.1 FIRE RESISTANCE RATING FOR TYPE I - 332 (HR)

COLUMNS

SUPPORTING MORE THAN ONE FLOOR 3 HOUR

SUPPORTING ONE FLOOR / ROOF ONLY 2 HOUR

BEAMS

SUPPORTING ONE FLOOR / ROOF ONLY 2 HOUR

FLOOR/CEILING ASSEMBLIES 2 HOUR

ROOF/CEILING ASSEMBLIES 1 1/2 HOUR

INTERIOR/EXTERIOR NONBEARING WALLS 0 HOUR

FIRE RATED REQUIREMENTS

FIRE RATING SCHEDULE

UL

REFERENCE

COLUMNS SUPPORTING ONE FLOOR

HOURLY

RATINGTYPE ELEMENT

I 2 HR UL X854

I COLUMNS SUPPORTING MORE

THAN ONE FLOOR

3 HR UL X854

COLUMNS SUPPORTING ROOFI 2 HR UL X854

FLOOR DECKSI 2 HR UL D779

FLOOR SUPPORTSI 2 HR UL P732

ROOF DECKSI 1 1/2 HR UL P732

ROOF SUPPORTSI 2 HR UL N732

FIRE RATED SCHEDULE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0 /2

:2

:5 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n E

H R

M /B

L D

G

T

R T

O W

E R

.r v t

02A-100G

BUILDING 02 - LEVEL 00G - DEMO, FLOOR

PLANS & RCPS

MA SR/RB

100% CONSTRUCTION

DOCUMENTS

06/27/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

1/4" = 1'-0"

LEVEL 00G - TR TOWER 3 - DEMO FLOOR PLAN

1/4" = 1'-0"

LEVEL 00G - TR TOWER 3 - DEMO RCP

1/4" = 1'-0"

RM T3-00G - FLOOR PLAN

1/4" = 1'-0"

RM T3-00G - RCP

1. ALL PRODUCTS AND FINISHES SHALL MATCH EXISTING OR

ADJACENT EXISTING UNLESS OTHERWISE NOTED.

2. PATCH AND REPAIR WALLS, FLOORS AND CEILINGS

WHERE MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS

ARE DEMOLISHED.

3. PROTECT FINISHES IN ROOMS ADJACENT TO THE AREA OF

WORK AND PARTS THAT ARE NOT INCLUDED IN THE

SCOPE.

4. CONTRACTOR SHALL LEAVE FIRE RATING STAMP

UNPAINTED AND VISIBLE ON THE NEW INSTALLED FRT

PLYWOOD. SEE DETAIL 5/AE401.

5. REFER TO SHEET AS101 FOR ICRA REQUIREMENTS AND

DETAILS.

6. PATCH AND REPAIR CEILING, WALLS AND FLOORS AS

REQUIRED WHERE ICRA BARRIERS WILL BE CONSTRUCTED

AND REMOVED.

7. REFER TO SHEET A-602 FOR DOOR SCHEDULE.

PROJECT

NORTH

PROJECT

NORTH

PROJECT

NORTH

PROJECT

NORTH

10 INSTALL TEMPORARY 1 HR CONSTRUCTION ICRA BARRIER TO

SEPARATE CONSTRUCTION AREA FROM OCCUPIED SPACE.

11 INSTALL FIRE RESISTANT TEMPORARY SELF-CLOSING DOOR,

SOLID CORE WOOD IN STEEL FRAME, PAINTED, AT OPENING

AND MATCH RATING OF ICRA BARRIER, TYPICAL.

12 PLACE TACKY MATS AT ENTRANCE AND EXIT OF

CONSTRUCTION AREA, MINIMUM SIZE 24"x36", TYPICAL.

1 DEMOLISH EXISTING WINDOW. PREPARE FOR NEW

DOOR/FRAME.

2 DEMOLISH PORTION OF EXISTING WALL. PREPARE FOR NEW

DOOR/FRAME.

3 INFILL WALL, PATCH AND PAINT TO MATCH EXISTING.

4 CONSTRUCT NEW WALL.

5 INSTALL NEW DOOR/FRAME.

6 CONSTRUCT NEW FLOOR.

7 APPLY ANTI-STATIC COATING TO EXPOSED FLOOR. PROVIDE

VINYL REDUCER STRIP AT EXISTING FLOORING TRANSITION.

8 INSTALL NEW RESILIENT RUBBER BASE AT ROOM PERIMETER

WITH SEALANT AT THE BOTTOM.

9 INSTALL FRT PLYWOOD OVER WALLS AS NEEDED PER DETAIL

3/AE401, TYPICAL.

GENERAL NOTES

KEY PLAN

KEY NOTES (THIS SHEET ONLY)

LEGEND

ICRA KEYNOTES

ICRA CLASS III LEGEND

09/03/20259/3/2025 128 OF 693

LEVEL 00G

0' - 0"

ROOF

11' - 9"

A7A4 T3-S1

LEVEL 00B

-13' - 9"

02A-100Gc

PARAPET COPING

VENEER BRICK

THRU-WALL SCUPPER

AND CONDUCTOR HEAD

DOWNSPOUT

PROVIDE BRACKET @

4'-0" OC, MAX

T3-S2

OVERFLOW DRAIN

2'

V E

R

IF

Y

IN

F

IE

LD

9'

LEVEL 00G

0' - 0"

ROOF

11' - 9"

LEVEL 00B

-13' - 9"

02A-100Gc

PARAPET CAP TO MATCH

ADJACENT

VENEER BRICK

EXPANSION JOINT COVER

EXISTING

ADJACENT BLDG

T3-SAT3-SB

EXISTING STAIR

EXISTING

RETAINING WALL

EXISTING PAVING

V E

R

IF

Y I N

F

IE

L D

EXISTING

ADJACENT BLDG

LEVEL 00G

0' - 0"

ROOF

11' - 9"

A7 T3-S1

LEVEL 00B

-13' - 9"

02A-100Gc

T3-S2

PARAPET COPING

VENEER BRICK

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0 /2

:3

:0 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n E

H R

M /B

L D

G

T

R T

O W

E R

.r v t

02A-100Gb

TR TOWER 3 - EXTERIOR ELEVATIONS

MA SR

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

1/4" = 1'-0"

TR TOWER 3 NORTH ELEVATION

1/4" = 1'-0"

TR TOWER 3 EAST ELEVATION

1/4" = 1'-0"

TR TOWER 3 SOUTH ELEVATION

09/03/20259/3/2025 129 OF 693

ROOF

11' - 9"

A7 A6

T3-S1

LEVEL 00B

-13' - 9"

02A-100Gc

184 SF

TR TOWER 3

T3-00G

175 SF

TR TOWER 3

T3-00B

SPRAY APPLY FIREPROOFING @

ALL STRUCTURAL MEMBERS,

TYP

EXTERIOR WALL:

• BRICK VENEER

• 2 3/16" AIR SPACE W/ 2"

ALUMINUM T- FURRING

• R-10ci RIGID INSULATION

• WRB

• 5/8" EXTERIOR GYPSUM BOARD

• 8" METAL STUDS @ 16" OC

• R-15 BATT INSULATION

• VAPOR RETARDER

• 5/8" TYPE X GYPSUM BOARD

T3-S2

CARPENTRY

SHOP

1444 SF

LAUNDRY

GD114

3268 SF

02AE-451

02AE-451

R1

F1

E1C

02c

DRAINAGE BOARD

DAMPPROOFING

PROTECTION

BOARD

GRAVEL

R-10 RIGID

INSULATION 24" @

PERIMETER

CONT VAPOR BARRIER

TPO ROOFING SYSTEM:

• ROOFING MEMBRANE

• 1/2" PROTECTION BOARD

• R-20ci MIN SLOPE TO DRAIN

• VAPOR RETARDER

• 3 1/4" CONCRETE FILL

• 2" METAL DECK

R-10 RIGID INSULATION

REFERENCE STRUCT

DRWGS FOR

FOUNDATION SYSTEM

F2

LEVEL 00G

0' - 0"

ROOF

11' - 9"

LEVEL 00B

-13' - 9"

02A-100Gc

SPRAY APPLY

FIREPROOFING @ ALL

STRUCTURAL

MEMBERS, TYP

184 SF

TR TOWER 3

T3-00G

175 SF

TR TOWER 3

T3-00B

EXTERIOR WALL:

• BRICK VENEER

• 2 3/16" AIR SPACE W/ 2"

ALUMINUM T- FURRING

• R-10ci RIGID INSULATION

• WRB

• 5/8" EXTERIOR GYPSUM BOARD

• 8" METAL STUDS @ 16" OC

• R-15 BATT INSULATION

• VAPOR RETARDER

• 5/8" TYPE X GYPSUM BOARD

T3-SA T3-SB

R1

E1C

F2

F1

E1C

DRAINAGE BOARD

DAMPPROOFING

PROTECTION

BOARD

GRAVEL

R-10 RIGID

INSULATION 24" @

PERIMETER

CONT VAPOR BARRIER

2'

1/4" / 1'-0"3/4" / 1'-0"

R-10 RIGID INSULATION

1' - 0"

COOLING/HEATING SYSTEM

PER MECH

TELECOM RACK, TYP

PANEL BOARD

DATA TRAY

TPO ROOFING SYSTEM:

• ROOFING MEMBRANE

• 1/2" PROTECTION BOARD

• R-20ci MIN SLOPE TO DRAIN

• VAPOR RETARDER

• 3 1/4" CONCRETE FILL

• 2" METAL DECK

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0 /2

:3

:1 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n E

H R

M /B

L D

G

T

R T

O W

E R

.r v t

02A-100Gc

TR TOWER 3 - BUILDING SECTIONS

MA SR

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

1/4" = 1'-0"

TR TOWER 3 SECTION EAST/WEST LOOKING SOUTH

1/4" = 1'-0"

TR TOWER 3 SECTION NORTHSOUTH LOOKING EAST

09/03/20259/3/2025 130 OF 693

A7 T3-S1

A8

A9

T3-SA

T3-SB

LINE OF NEW ROOF

BUILDING 2 ROOF

T3-S2

A7 T3-S1

A8

A9

T3-SA

T3-SB

1 3/ 4"

1'

-0

T3-S2

/4

R1

THRU-WALL SCUPPER AND

DOWNSPOUT, RE: 3/01S-A-513 (SIM)

OVERFLOW DRAIN

BUILDING 2 ROOF

SHOWN AREA

PROJECT

NORTH

TR TOWER 3

01W

0223R 01S

01A

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0 /2

:3

:1 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n E

H R

M /B

L D

G

T

R T

O W

E R

.r v t

02A-100R

BUILDING 02 - ROOF PLAN

MA SR

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

1/2" = 1'-0"

TR TOWER 3 - ROOF PLAN (EXISTING)

1/2" = 1'-0"

TR TOWER 3 - ROOF PLAN

PROJECT

NORTH

PROJECT

NORTH

GENERAL NOTES

KEY PLAN

KEY NOTES (THIS SHEET ONLY)

1. ALL PRODUCTS AND FINISHES SHALL MATCH EXISTING OR

ADJACENT EXISTING UNLESS OTHERWISE NOTED.

2. PATCH AND REPAIR WALLS, FLOORS AND CEILINGS

WHERE MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS

ARE DEMOLISHED.

3. PROTECT FINISHES IN ROOMS ADJACENT TO THE AREA OF

WORK AND PARTS THAT ARE NOT INCLUDED IN THE

SCOPE.

4. CONTRACTOR SHALL LEAVE FIRE RATING STAMP

UNPAINTED AND VISIBLE ON THE NEW INSTALLED FRT

PLYWOOD. SEE DETAIL 5/AE421.

5. REFER TO SHEET AS101 FOR ICRA REQUIREMENTS AND

DETAILS.

6. PATCH AND REPAIR CEILING, WALLS AND FLOORS AS

REQUIRED WHERE ICRA BARRIERS WILL BE CONSTRUCTED

AND REMOVED.

1 CONSTRUCT NEW ROOF.

09/03/20259/3/2025 131 OF 693

ROOF

11' - 9"

LEVEL 00B

-13' - 9"

T3-SB

CONCRETE FOOTING

PER STRUCT

R-1O RIGID

INSULATION

CONT VAPOR

BARRIER

CONT 20 GA FORMED

Z CLIP WITH 1 1/2"

LEGS ATTACHED TO

BEAM AT 16" OC MAX

FILL GAP WITH

MINERAL WOOL

INSULATION

AIR & WATER

RESISTANCE BARRIER

CONT Z-CHANNEL

STAINLESS STEEL

HEX HEAD SELF

DRILLING SCREWS

R-10 RIGID

INSULATION

EXTRUDED

ALUMINUM T-

PROFILE GRADE

6063T6 MILL FINISH

SAND LAME / POLYMER

CEMENT POINTING

MORTAR

3/4"

PRE-FINISHED SHEET

METAL PARAPET CAP

FLASHING WITH

WATERTIGHT JOINT

ROOF FLASHING

MEMBRANE WRAP OVER

TOP OF PARAPET WALL

/2

/2

T3-SB

T3-S2

02A-501

1'

7"

3"

3"

1'

9"

04a

04a

02c

C1

3/4"x3/4"x1/8" GALV

SHEET METAL TRIM

3/4" PLYWOOD LINER

FILL GAP WITH

SEALANT

2 HR FIRE RATED SHAFT

WALL

175 SF

TR TOWER 3

T3-00B

02b

C1

T3-SB

T3-S2

02A-501

04a

04a 3/4"x3/4"x1/8" GALV

SHEET METAL TRIM

3/4" PLYWOOD LINER

FILL GAP WITH

SEALANT

2 HR FIRE RATED SHAFT

WALL

1'

1"

E1C

E1C

184 SF

TR TOWER 3

T3-00G

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0 /2

:3

:2 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n E

H R

M /B

L D

G

T

R T

O W

E R

.r v t

02A-501

TR TOWER T3 MECH SHAFT DETAILS

MA SR

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

Revisions: Date:

1 1/2" = 1'-0"

TR TOWER T3 MECH SHAFT - SECTION

1 1/2" = 1'-0"

RM T3-00B - MECH SHAFT ENLARGED FLOOR PLAN

PROJECT

NORTH

1 1/2" = 1'-0"

RM T3-00G - MECH SHAFT ENLARGED PLAN

PROJECT

NORTH

09/03/20259/3/2025 132 OF 693

AIR & WATER

RESISTANCE BARRIER

CONT Z-CHANNEL

FAST FLASH OVER

FLOOR JOINT

ALUMINUM BRACKET @

32" OC

STAINLESS STEEL HEX

HEAD SELF DRILLING

SCREWS

R-10 RIGID INSULATION

EXTRUDED ALUMINUM T-

PROFILE GRADE 6063T6

MILL FINISH

BACKER ROD &

SEALANT IN JOINT

EPDM OR FOAMED

POLYETHYLENE SILL

SEALER

R-13 BATT INSULATION

CONT VAPOR RETARDER 5/8" GWB

1/2" FIRE TREATED

PLYWOOD SHEATHING

CONCRETE TOPPING

OVER METAL DECK

PER STRUCT

FLOOR FINISH AND

BASE PER FINISH

SCHEDULE, TYP

SPRAY APPLIED

FIREPROOFING

CONT 20 GA FORMED Z CLIP

WITH 1 1/2" LEGS ATTACHED

TO BEAM AT 16" OC MAX

FILL GAP WITH MINERAL

WOOL INSULATION

CONT DEFLECTION TRACK

ATTACHED TO Z-CLIP AT

16" OC MAX

3/4"x3/4" GALV

SHEET METAL TRIM

FILL GAP WITH MINERAL

WOOL INSULATION

RAIL MODIFIED TO

BRAKE INTERLOCK AND

ALLOW FOR MOVEMENT

ROOF

11' - 9"

1/2" COVER BOARD

TREATED WOOD

NAILERS TO MATCH

HEIGHT OF INSULATION

AND COVER BOARD

FLASHING MEMBRANE

HOT-AIR WELD

ROOFING MEMBRANE

R-30ci RIGID

INSULATION, MIN

PRE-FINISHED SHEET

METAL PARAPET CAP

FLASHING WITH

WATERTIGHT JOINT

ROOF FLASHING

MEMBRANE WRAP OVER

TOP OF PARAPET WALL

VAPOR

RETARDER

AIR & WATER

RESISTANCE BARRIER

GWB SHEATHING

CONT Z-CHANNEL

FAST FLASH OVER

FLOOR JOINT

ALUMINUM BRACKET @

32" OC

STAINLESS STEEL HEX

HEAD SELF DRILLING

SCREWS

VENTILATION GAP

PROTECTED WITH

INSECT MESH

1"

/2

/2 "0"

/8

/8

1 3/8"2 1/4" 2" 1/2" 8"

R-10 RIGID INSULATION

EXTRUDED ALUMINUM T-

PROFILE GRADE 6063T6

MILL FINISH

CORIUM BRICK

CORIUM BRICK TRAY

SAND LAME / POLYMER

CEMENT POINTING

MORTAR

RAIL MODIFIED TO

BRAKE INTERLOCK AND

ALLOW FOR MOVEMENT

LEVEL 00B

-13' - 9"

PROVIDE NEW LOOSE

LINTEL AT NEW DOOR

OPENING, TYP

5/8" GWB OVER (E) STUDS @

AREA ABOVE NEW DOOR

OPENING

5/8" GWB OVER 2 1/2" STUDS

@ 16" OC ABOVE NEW DOOR

OPENING

EXISTING BUILDINGNEW ADDITION

EXP JT

2 1/2"

MBF2H0350

FIRE STOPPING, TYP

2HBCP-2-250

MILL FINISH ALUMINUM FLOOR

EXPANSION JOINT COVER

2 HOUR RATED WITH

MBF2H0350

UL LISTING FF-D-1071

50% MOVEMENT

TYPICAL AT EXISTING FLOOR

CONNECTION

1" M

IN

2" 5/

8"

PROVIDE CASING BEAD AT

GWB EXPOSED EDGE, TYP

EXISTING CONCRETE

TO REMAIN

ROOF

11' - 9"

CONT BEAD OF SEALANT

EXISTING PARAPET

TREATED WOOD NAILERS

FLASHING MEMBRANE

HOT-AIR WELD

2H9WC-2

MILL FINISH ALUMINUM EXTERIOR

ROOF TO WALL EXPANSION JOINT

COVER W/ 2-HOUR FIRE BARRIER

MPFV2H08

W/45 MIL EPDM WATER BARRIER

50% MOVEMENT 5/

8" 3"

1/ 4"

8"

MBF2H0238

2"

T3-S2

EXTRUDED ALUMINUM

"T" PROFILE

ALUMINUM BRACKET

@ 32" OC

STAINLESS STEEL

HEX HEAD SELF

DRILLING SCREWS

CORIUM VENEER BRICK

SYSTEM

PERFORATED ANGLE

1/4" SEALANT &

BACKER ROD

BACKER ROD &

SEALANT IN JOINT,

BOTH SIDES, TYP

WATER FLOW

EPDM OR FOAMED

POLYETHYLENE SILL

SEALER

ALUMINUM BASE

FLASHING WITH HEMMED

EDGE OVER R-GUARD

FASTFLASH

WRAP WRB OVER BASE

FLASHING OVER SELF

ADHERE FLEXIBLE FLASHING

(SAFF)

M

IN

M

IN

GRADE PER CIVIL

02b

E1C

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0 /2

:3

:2 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n E

H R

M /B

L D

G

T

R T

O W

E R

.r v t

02A-511

EXTERIOR DETAILS

MA SR

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

3" = 1'-0"

TR TOWER 3 TYPICAL DETAIL @ FLOOR

3" = 1'-0"

TR TOWER 3 TYPICAL DETAIL - PARAPET

3" = 1'-0"

TR TOWER 3 TYPICAL DETAIL - DOOR HEAD / SILL

3" = 1'-0"

TR TOWER 3 SECTION DETAIL - (E) PARAPET

Revisions: Date:

3" = 1'-0"

TR TOWER 3 - TYPICAL WALL BASE DETAIL

09/03/20259/3/2025 133 OF 693

A7 T3-S1

CONT 3/4"x3/4"x1/8"

GALV SHEET METAL

TRIM

3/4" PLYWOOD LINER

5/8" TYPE X GWB OVER

1 1/2" METAL STUDS @

16" OC

1 HR FIRE RATED HM

DOOR AND FRAME, TYP

PRECOMPRESSED

POLYURETHANE

MICROCELL FOAM

2HEXFL-2

MILL FINISH ALUMINUM JOINT

COVER

MILL FINISH ALUMINUM BASE

W/ 2 HOUR FIRE BARRIER;

MBF20350

UL LISTING # FF-D-1071

50% MOVEMENT

1'

3/ 8"

1'

3/ 8"

1' - 7 3/4" 5/8"

EXISTING WALL

2" 1'

1'

2"

PATCH EXISTING WALL

1' - 6"

02a

T3-00B

IN-03.01-18

175 SF

TR TOWER 3

T3-00B

CARPENTRY

SHOP

1444 SF

A7 T3-S1

CONT 3/4"x3/4"x1/8"

GALV SHEET METAL

TRIM

3/4" PLYWOOD LINER

1 HR FIRE RATED HM

DOOR AND FRAME, TYP

PRECOMPRESSED

POLYURETHANE

MICROCELL FOAM 2HEXFL-2

MILL FINISH ALUMINUM JOINT

COVER

MILL FINISH ALUMINUM BASE

W/ 2 HOUR FIRE BARRIER;

MBF20350

UL LISTING # FF-D-1071

50% MOVEMENT

1'

3/ 8"

1'

3/ 8"

EXISTING WALL

2" 1'

1'

2"

PATCH EXISTING WALL

1' - 6"

1' - 6"

02c

02a

02a

02c

T3-00G

IN-03.01-19

184 SF

TR TOWER 3

T3-00G

LAUNDRY

GD114

3268 SF

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0 /2

:3

:2 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n E

H R

M /B

L D

G

T

R T

O W

E R

.r v t

02A-512

EXTERIOR DETAILS

MA SR

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

1 1/2" = 1'-0"

ENLARGED PLAN - ENTRY DOOR LEVEL 00B

1 1/2" = 1'-0"

ENLARGED PLAN - ENTRY DOOE LEVEL 00G

09/03/20259/3/2025 134 OF 693

ROOF

11' - 9"

LEVEL 00B

-13' - 9"

T3-S2

DRAINAGE BOARD

OVER RIGID

INSULATION

DAMPPROOFING

PROTECTION

BOARD

GRAVEL

02A-511

F1

F2

R1

E1C

184 SF

TR TOWER 3

T3-00G

TR TOWER 3

T3-00B

CABLE TRAY PER

ELECT

CABLE TRAY PER

ELECT

LIGHTING FIXTURE

PER ELECT

PANEL BOARD

PER ELECT

PLYWOOD LINER

SPRAY APPLIED

FOREPROOFING

1/2" EXPANSION JOINT

R-10ci RIGID

INSULATION

REINFORCED

CONCRETE WALL PER

STRUCT

FILTER FABRIC

SURROUNDING COARSE

GRAVEL

PERIMETER DRAIN

SYSTEM

CONCRETE FOOTING

PER STRUCT

R-1O RIGID INSULATION

CONT VAPOR BARRIER

02b

02A-501

02A-511

02A-511

LEVEL 00G

0' - 0"

ROOF

11' - 9"

A7T3-S1

LEVEL 00B

-13' - 9"

184 SF

TR TOWER 3

T3-00G

LAUNDRY

GD114

3268 SF

175 SF

TR TOWER 3

T3-00B

CARPENTRY

SHOP

1444 SF

7'

02a

AFF

GWB SOFFIT

7' - 6"

R1

F2

F1

AFF

GWB SOFFIT

7' - 6"

CABLE TRAY

PER ELECT

SPRAY APPLIED

FOREPROOFING

NEW TR TOWER 3 EXISTING BLDG 2

02A-511

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0 /2

:3

:4 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n E

H R

M /B

L D

G

T

R T

O W

E R

.r v t

02AE-451

WALL SECTIONS

MA SR

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

1/2" = 1'-0"

TR TOWER 3 EAST WALL SECTION

1/2" = 1'-0"

TR TOWER 3 WEST WALL SECTION

09/03/20259/3/2025 135 OF 693

TR

ICRA PHASING LINE

ICRA CLASS III

ICRA CLASS IV

FIRE EXTINGUISHER CABINETFEC

FIRE EXTINGUISHERFE

ICRA CLASS II

A B C D E

F G

550 SF

BOILER 4

SP3016-3

423 SF

STORAGE

SP3005-3

262 SF

TANKS

SP3004-3

307 SF

GENERATOR

SP3000-3

258 SF

PARTS

SP3001-3

119 SF

CONTROL

SP3012-3

796 SF

BOILER 1

SP3013-3

85 SF

KITCHEN

SP3000-3

432 SF

BOILER 2

SP3014-3

398 SF

BOILER 3

SP3015-3

84 SF

PIT

467 SF

PUMP

SP3011-3

312 SF

TANKS

SP30004A-3

D

IA

M O

N D

L

IN

E

DIAMOND LINE

PHASE 1:

CONTRACTOR TO COMPLETE THE WORK OF THIS

TR AND ASSOCIATED DATA DROPS. COMPLETE

ONE SECTION AT A TIME AS DIRECTED TO COR.

SECTION 1A:

CONTRACTOR TO COORDINATE WITH VA FOR ROOM

CLOSURES AND AVAILABILITY TO COMPLETE DATA

WIRING IN THIS AREA.

NEW SEMI-RECESSED FEC, TO MATCH

OR EXCEED EXISTING EXTINGUISHER IN

ABC RATING AND SIZE. SEE DET 4/A-604.

FEC

40 SF

TE

SP3005-3A

RM SP3005-3A

KEY AREA SHOWN

PROJECT

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0

/2

:1

:0 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n

E H

R M

/B L

D G

.r v t

03AS101

BUILDING 03 - LEVEL 01 - PHASING PLAN

MA RB

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

KEY PLAN

LEGEND

1/4" = 1'-0"

BUILDING 03 - LEVEL 01 - PHASING PLAN

0' 2' 4' 8'

PROJECT

NORTH

09/03/20259/3/2025 136 OF 693

KEY AREA SHOWN

PROJECT

NORTH

TO DEMOLISH

EXISTING DOOR TO REMAIN

EXISTING DOOR TO DEMOLISH

NEW DOOR

EXISTING LIGHTS TO DEMOLISH

NEW LIGHTS (SEE ELECTRICAL DETAILS)

E F

ENTRY

POINT

5 5

E F

262 SF

TANKS

SP3004-3

423 SF

STORAGE

SP3005-3

01bS P

-3

± 6' - 0" (EXIST.)

(E

X

IS

T

40 SF

TE

SP3005-3A

N E

W

F L O

O R

IN

G

EXISTING

FLOORING

IN-01.02

E F

EXPOSED

E F

262 SF

TANKS

SP3004-3

EXPOSED

423 SF

STORAGE

SP3005-3

1' - 0"

40 SF

TE

SP3005-3A

EXPOSED

RM SP3005-3A

423 SF

STORAGE

SP3005-3

262 SF

TANKS

SP3004-3

423 SF

STORAGE

SP3005-3

262 SF

TANKS

SP3004-3

POLYETHYLENE SHEETING

CONSTRUCTION TACK MAT

HEPA EQUIPPED AIR FILTER

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0

/2

:1

:0 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n

E H

R M

/B L

D G

.r v t

03A-101

BUILDING 03 - LEVEL 01 - DEMO, FLOOR

PLANS, & RCPS

MA ME/RB

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

PROJECT

NORTH

PROJECT

NORTH

PROJECT

NORTH

PROJECT

NORTH

3/8" = 1'-0"

RM SP3005-3 - DEMO FLOOR PLAN

3/8" = 1'-0"

RM SP3005-3A - FLOOR PLAN

3/8" = 1'-0"

RM SP3005-3 - DEMO RCP

3/8" = 1'-0"

RM SP3005-3A - RCP

1. ALL PRODUCTS AND FINISHES SHALL MATCH EXISTING OR

ADJACENT EXISTING UNLESS OTHERWISE NOTED.

2. PATCH AND REPAIR WALLS, FLOORS AND CEILINGS

WHERE MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS

ARE DEMOLISHED.

3. PROTECT FINISHES IN ROOMS ADJACENT TO THE AREA OF

WORK AND PARTS THAT ARE NOT INCLUDED IN THE

SCOPE.

4. CONTRACTOR SHALL LEAVE FIRE RATING STAMP

UNPAINTED AND VISIBLE ON THE NEW INSTALLED FRT

PLYWOOD. SEE DETAIL 5/AE401.

5. REFER TO SHEET AS101 FOR ICRA REQUIREMENTS AND

DETAILS.

6. PATCH AND REPAIR CEILING, WALLS AND FLOORS AS

REQUIRED WHERE ICRA BARRIERS WILL BE CONSTRUCTED

AND REMOVED.

4 INSTALL POLYETHYLENE SHEETING TO ISOLATE

CONSTRUCTION ZONE. TAPE AND SEAL ALONG EDGES, AND

ANY AREAS WHERE POTENTIAL DUST MAY BE EXPOSED

OUTSIDE OF CONSTRUCTION AREA.

5 PLACE TACKY MATS AT ENTRANCE AND EXIT OF

CONSTRUCTION AREA, MINIMUM SIZE 24"x36", TYPICAL.

1 THIS SPACE WILL BE UTILIZED FOR NEW

TELECOMMUNICATION ENCLOSURE. PROVIDE NEW FRT

PLYWOOD OVER WALLS PER DETAIL 3/AE401, TYPICAL.

2 INFILL WALL, PATCH AND PAINT TO MATCH EXISTING.

3 INSTALL NEW DOOR/FRAME.

GENERAL NOTES

KEY PLAN

KEY NOTES (THIS SHEET ONLY)

LEGEND

ICRA CLASS II LEGEND

ICRA KEYNOTES

09/03/20259/3/2025 137 OF 693

ICRA CLASS III

ICRA CLASS IV

FIRE EXTINGUISHER CABINETFEC

FIRE EXTINGUISHERFE

ICRA CLASS II

KEY AREA SHOWN

PROJECT

NORTH

A B C D E

F G

70 SF

OFFICE

73 SF

TOILET

2265 SF

MEZZANINE

423 SF

ELEC SHOP

SECTION 1A:

CONTRACTOR TO COORDINATE WITH VA FOR ROOM

CLOSURES AND AVAILABILITY TO COMPLETE DATA

WIRING IN THIS AREA.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0

/2

:1

:0 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n

E H

R M

/B L

D G

.r v t

03AS102

BUILDING 03 - LEVEL 02 - PHASING PLAN

MA RB

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

KEY PLAN

LEGEND

0' 2' 4' 8'

PROJECT

NORTH

1/4" = 1'-0"

BUILDING 03 - LEVEL 02 - PHASING PLAN

09/03/20259/3/2025 138 OF 693

A B C D E F G H I J K L M N

389 SF

CAN STORAGE

28 SF

STAIRS

181 SF

RECEIVING

1494 SF

RETAIL STORE

1332 SF

DINING ROOM

397 SF

EXT SHELTER

133 SF

MEN

145 SF

WOMEN

95 SF

TR

57 SF

ELEVATOR

70 SF

ELEV ROOM

18 SF

STORAGE

2009 SF

SERVING AREA

222 SF

REFRIGERATORS

126 SF

SALAD ROOM

313 SF

MECHANICAL

E-121

130 SF

ELEC

E-122 92 SF

SECURE STOR

24 SF

STAFF TLT

379 SF

DISHWASHING

278 SF

KITCHEN

438 SF

RETAIL STOCK

236 SF

RETAIL STOCK

122 SF

LOCKER

333 SF

CORRIDOR

407 SF

CHIEF VCS

154 SF

NO ROOM

NUMBER

NRN

PHASE 1:

CONTRACTOR TO COMPLETE THE WORK OF

THIS TR AND ASSOCIATED DATA DROPS.

COMPLETE ONE SECTION AT A TIME AS

DIRECTED TO COR.

D

IA

M O

N D

L

IN

E

DIAMOND LINE

SECTION 1A:

CONTRACTOR TO COORDINATE WITH VA

FOR ROOM CLOSURES AND AVAILABILITY

TO COMPLETE DATA WIRING IN THIS AREA.

SECTION 1B:

CONTRACTOR TO COORDINATE WITH VA

FOR ROOM CLOSURES AND AVAILABILITY

TO COMPLETE DATA WIRING IN THIS AREA.

FEC

NEW SEMI-RECESSED FEC, TO MATCH

OR EXCEED EXISTING EXTINGUISHER IN

ABC RATING AND SIZE. SEE DET 4/A-604.

RM 4001

KEY AREA SHOWN

PROJECT

NORTH

TR

ICRA PHASING LINE

ICRA CLASS III

ICRA CLASS IV

FIRE EXTINGUISHER CABINETFEC

FIRE EXTINGUISHERFE

ICRA CLASS II

2 HR FIRE RATED WALL

SMOKE RATED WALL

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0

/2

:0

:4 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n

E H

R M

/B L

D G

.r v t

04AS100

BUILDING 04 - LEVEL 00 - PHASING PLAN

MA CO/RB

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

KEY PLAN

LEGEND

3/16" = 1'-0"

BUILDING 04 - LEVEL 00 - PHASING PLAN

0' 2' 4' 8'

PROJECT

NORTH

09/03/20259/3/2025 139 OF 693

NORTH

L M N

DUCT O EXTERIOR

3' - 8"

145 SF

WOMEN

18 SF

STORAGE

57 SF

ELEVATOR

333 SF

CORRIDOR

95 SF

OFFICE

333 SF

CORRIDOR

L M N

145 SF

WOMEN

95 SF

OFFICE

57 SF

ELEVATOR

18 SF

STORAGE

333 SF

CORRIDOR

333 SF

CORRIDOR

L M N

145 SF

WOMEN

95 SF

TR

57 SF

ELEVATOR

18 SF

STORAGE

333 SF

CORRIDOR

NEW

FLOORING

EXISTING

FLOORING

± 8' - 7" (EXIST.)

/2

(E X

IS

T

10'x8' TR FORM FACTOR

IN-03.01-20

IN-01.31

01b

7 8

2"X2" TRENCH ALONG WALL WITH

SLOTTED METAL COVER. COORDINATE

WATER SENSOR WITH MECHANICAL

AND ELECTRICAL.

L M N

145 SF

WOMEN

95 SF

TR

57 SF

ELEVATOR

18 SF

STORAGE

333 SF

CORRIDOR

EXPOSED

1' - 4"

1' - 4"

1' - 4"

1' - 4"

RM 4001

TO DEMOLISH

EXISTING DOOR TO REMAIN

EXISTING DOOR TO DEMOLISH

NEW DOOR

EXISTING LIGHTS TO DEMOLISH

2 HR FIRE RATED WALL

NEW LIGHTS (SEE ELECTRICAL DETAILS)

( + ) PRESSURE

CONSTRUCTION ZONE, (--) PRESSURE

TEMPORARY ICRA BARRIER

TEMPORARY ICRA DOOR

CONSTRUCTION TACKY MAT

HEPA EQUIPPED EXHAUST

1/4" = 1'-0"

RM 4001 - DEMO FLOOR PLAN

1/4" = 1'-0"

RM 4001 - DEMO RCP

1/4" = 1'-0"

RM 4001 - FLOOR PLAN

1/4" = 1'-0"

RM 4001 - RCP

PROJECT

NORTH

PROJECT

NORTH

PROJECT

NORTH

PROJECT

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0

/2

:0

:4 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n

E H

R M

/B L

D G

.r v t

04A-100

BUILDING 04 - LEVEL 00 - DEMO, FLOOR PLAN

& RCPS

MA ME/RB

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

1. ALL PRODUCTS AND FINISHES SHALL MATCH EXISTING OR

ADJACENT EXISTING UNLESS OTHERWISE NOTED.

2. PATCH AND REPAIR WALLS, FLOORS AND CEILINGS

WHERE MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS

ARE DEMOLISHED.

3. PROTECT FINISHES IN ROOMS ADJACENT TO THE AREA OF

WORK AND PARTS THAT ARE NOT INCLUDED IN THE

SCOPE.

4. CONTRACTOR SHALL LEAVE FIRE RATING STAMP

UNPAINTED AND VISIBLE ON THE NEW INSTALLED FRT

PLYWOOD. SEE DETAIL 5/AE401.

5. REFER TO SHEET AS101 FOR ICRA REQUIREMENTS AND

DETAILS.

6. PATCH AND REPAIR CEILING, WALLS AND FLOORS AS

REQUIRED WHERE ICRA BARRIERS WILL BE CONSTRUCTED

AND REMOVED.

7. PATCH AND REPAIR GWB WHERE DOOR IS DEMOLISHED AND

A NEW DOOR WILL BE INSTALLED.

8. REFER TO SHEET A-602 FOR DOOR SCHEDULE.

10 INSTALL FRT PLYWOOD OVER WALLS AS NEEDED PER

DETAIL 3/AE421, TYPICAL.

11 INSTALL TEMPORARY 1 HR CONSTRUCTION ICRA BARRIER

TO SEPARATE CONSTRUCTION AREA FROM OCCUPIED

SPACE.

12 INSTALL FIRE RESISTANT TEMPORARY SELF-CLOSING DOOR,

SOLID CORE WOOD IN STEEL FRAME, PAINTED, AT OPENING

AND MATCH RATING OF ICRA BARRIER, TYPICAL.

13 PLACE TACKY MATS AT ENTRANCE AND EXIT OF

CONSTRUCTION AREA, MINIMUM SIZE 24"x36", TYPICAL.

1 DEMOLISH EXISTING DOOR/FRAME.

2 DEMOLISH EXISTING BASE. REMOVE EXISTING ADHESIVE

AND PREPARE FOR NEW BASE.

3 DEMOLISH EXISTING FLOOR FINISH TO EXPOSE FLOOR

STRUCTURE UNDERNEATH. REMOVE ANY EXISTING

SUBSTANCE/BONDING AGENT IF ANY. PREPARE FLOORING

FOR NEW WORK.

4 DEMOLISH PORTION OF EXISTING WALL. PREPARE FOR NEW

DOOR/FRAME.

5 DEMOLISH EXISTING ACT COMPLETELY INCLUDING ALL

GRIDS, SUPPORTING WIRES, CLIPS, AND PERIMETER WALL

ANGLES TO EXPOSE UNDERSIDE OF STRUCTURE ABOVE.

PATCH WALLS WHERE CEILING IS REMOVED.

6 INSTALL NEW DOOR/FRAME.

7 APPLY ANTI-STATIC COATING TO EXPOSED FLOOR. PROVIDE

VINYL REDUCER STRIP AT EXISTING FLOORING TRANSITION.

8 INSTALL NEW RESILIENT RUBBER BASE AT ROOM

PERIMETER WITH SEALANT AT THE BOTTOM.

9 INFILL WALL, PATCH AND PAINT TO MATCH EXISTING.

GENERAL NOTES

KEY PLAN

KEY NOTES (THIS SHEET ONLY)

LEGEND

ICRA KEYNOTES

Revisions: Date:

ICRA CLASS III LEGEND

09/03/20259/3/2025 140 OF 693

415 SF

MECHANICAL

STAIRS

221 SF

VOL SVC

STORAGE

645 SF

VOLUNTARY

STORAGE

75 SF

KITCHEN

156 SF

REC HALL

STORAGE

2585 SF

AUDITORIUM

199 SF

VCS STOR

126 SF

MEDIA

169 SF

STAIR

541 SF

LOBBY

286 SF

CREDIT UNION

-138 SF

OFFICE

22 SF

JANITOR

99 SF

ELEVATOR

187 SF

VCS STORAGE

SECTION 1A:

CONTRACTOR TO COORDINATE WITH VA

FOR ROOM CLOSURES AND AVAILABILITY

TO COMPLETE DATA WIRING IN THIS AREA.

SECTION 1B:

CONTRACTOR TO COORDINATE WITH VA FOR

ROOM CLOSURES AND AVAILABILITY TO

COMPLETE DATA WIRING IN THIS AREA.

110 SF

EE

KEY AREA SHOWN

PROJECT

NORTH

TR

ICRA PHASING LINE

ICRA CLASS III

ICRA CLASS IV

FIRE EXTINGUISHER CABINETFEC

FIRE EXTINGUISHERFE

ICRA CLASS II

2 HR FIRE RATED WALL

SMOKE RATED WALL

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0

/2

:0

:4 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n

E H

R M

/B L

D G

.r v t

04AS101

BUILDING 04 - LEVEL 01 - PHASING PLAN

MA CO/RB

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

KEY PLAN

LEGEND

3/16" = 1'-0"

BUILDING 04 - LEVEL 01 - PHASING PLAN

0' 2' 4' 8'

PROJECT

NORTH

09/03/20259/3/2025 141 OF 693

2389 SF

OPEN TO BELOW

845 SF

OPEN TO BELOW

18 SF

TLT

175 SF

FITNESS

209 SF

FITNESS

74 SF

FOYER

120 SF

REC THER

99 SF

VAPD

368 SF

EXERCISE

122 SF

LOCKER

104 SF

LANDING

84 SF

WOMEN

64 SF

MEN

81 SF

FITNESS

143 SF

FITNESS

202 SF

FITNESS

89 SF

LOCKER

SECTION 1B:

CONTRACTOR TO COORDINATE WITH VA FOR

ROOM CLOSURES AND AVAILABILITY TO

COMPLETE DATA WIRING IN THIS AREA.

SECTION 1A:

CONTRACTOR TO COORDINATE WITH VA FOR

ROOM CLOSURES AND AVAILABILITY TO

COMPLETE DATA WIRING IN THIS AREA.

SECTION 1A:

CONTRACTOR TO COORDINATE WITH VA FOR

ROOM CLOSURES AND AVAILABILITY TO

COMPLETE DATA WIRING IN THIS AREA.

KEY AREA SHOWN

PROJECT

NORTH

TR

ICRA PHASING LINE

ICRA CLASS III

ICRA CLASS IV

FIRE EXTINGUISHER CABINETFEC

FIRE EXTINGUISHERFE

ICRA CLASS II

2 HR FIRE RATED WALL

SMOKE RATED WALL

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0

/2

:0

:4 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n

E H

R M

/B L

D G

.r v t

04AS102

BUILDING 04 - LEVEL 02 - PHASING PLAN

MA CO/RB

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

KEY PLAN

LEGEND

3/16" = 1'-0"

BUILDING 04 - LEVEL 02 - PHASING PLAN

0' 2' 4' 8'

PROJECT

NORTH

09/03/20259/3/2025 142 OF 693

ICRA CLASS III

ICRA CLASS IV

FIRE EXTINGUISHER CABINETFEC

FIRE EXTINGUISHERFE

ICRA CLASS II

2 HR FIRE RATED WALL

SMOKE RATED WALL

A B C D E F G H I J K L M N O P

3.5

695 SF

GROUP ROOM 1

300 SF

KITCHEN

358 SF

GROUP ROOM 2

166 SF

EXAM

579 SF

CORRIDOR

5000A

49 SF

ELEV.

5E1

44 SF

50 SF

MEN

47 SF

WOMEN

120 SF

COUNSEL

147 SF

STAFF

LOUNGE

52 SF

STOR

119 SF

ELEC

173 SF

TR

38 SF

WOMEN

38 SF

MEN

64 SF

COMMUNICATION

437 SF

GROUP ROOM 3

44 SF

ELEV. EQUIP

182 SF

CORRIDOR

5000B

156 SF

MECHANICAL

61 SF

SPKR

111 SF

STAIR 2

PIT

159 SF

COUNSEL

138 SF

ENTRANCE

LOBBY

48 SF

STOR

D

IA

M O

N D

L

IN

E

DIAMOND LINE

PHASE 1:

CONTRACTOR TO COMPLETE THE WORK OF THIS TR AND

ASSOCIATED DATA DROPS. COMPLETE ONE SECTION AT A

TIME AS DIRECTED TO COR.

SECTION 1B:

CONTRACTOR TO COORDINATE WITH VA FOR ROOM

CLOSURES AND AVAILABILITY TO COMPLETE DATA WIRING IN

THIS AREA.

SECTION 1A:

CONTRACTOR TO COORDINATE WITH VA FOR ROOM

CLOSURES AND AVAILABILITY TO COMPLETE DATA

WIRING IN THIS AREA.

NEW SEMI-RECESSED FEC, TO MATCH

OR EXCEED EXISTING EXTINGUISHER IN

ABC RATING AND SIZE. SEE DET 4/A-604.

FEC

RM 5044

KEY AREA SHOWN

PROJECT

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0

/2

:5

:5 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n

E H

R M

/B L

D G

.r v t

05AS100

BUILDING 05 - LEVEL 00 - PHASING PLAN

MA RB

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

KEY PLAN

LEGEND

3/16" = 1'-0"

BUILDING 05 - LEVEL 00 - PHASING PLAN

PROJECT

NORTH

0' 2' 4' 8'

09/03/20259/3/2025 143 OF 693

TO DEMOLISH

EXISTING DOOR TO REMAIN

EXISTING DOOR TO DEMOLISH

NEW DOOR

EXISTING LIGHTS TO DEMOLISH

2 HR FIRE RATED WALL

NEW LIGHTS (SEE ELECTRICAL DETAILS)

KEY AREA SHOWN

PROJECT

NORTH

RM 5044

O P

SEAL DOOR DURING

CONSTRUCTION

DUCT O EXTERIOR

11 11

O P

173 SF

TR

38 SF

WOMEN

182 SF

CORRIDOR

5000B

5 6

N E

W

O

O R

IN

G

EXISTING

FLOORING

119 SF

ELEC

FOR EXCEPTION

± 9' - 10 3/8" (EXIST.)

/8

(E X

IS

T

10'x10' TR

FORM FACTOR

IN-03.01-21

38 SF

MEN

IN

-0

.3

01b

2"X2" TRENCH ALONG WALL WITH

SLOTTED METAL COVER.

COORDINATE WATER SENSOR WITH

MECHANICAL AND ELECTRICAL.

O P

EXPOSED

O P

173 SF

TR

182 SF

CORRIDOR

5000B

38 SF

WOMEN

64 SF

COMMUNICATION

EXPOSED

119 SF

ELEC

2' - 1"

1' - 9" 2' - 1"

1' - 9"

173 SF

IRM

182 SF

CORRIDOR

5000B

119 SF

ELEC

38 SF

WOMEN

38 SF

MEN

173 SF

IRM

182 SF

CORRIDOR

5000B

119 SF

ELEC

38 SF

WOMEN

64 SF

COMMUNICATION

( + ) PRESSURE

CONSTRUCTION ZONE, (--) PRESSURE

TEMPORARY ICRA BARRIER

TEMPORARY ICRA DOOR

CONSTRUCTION TACKY MAT

HEPA EQUIPPED EXHAUST

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0

/2

:5

:5 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n

E H

R M

/B L

D G

.r v t

05A-100

BUILDING 05 - LEVEL 00 - DEMO, FLOOR PLAN

& RCPS

MA ME/RB

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

1/4" = 1'-0"

RM 5044 - DEMO FLOOR PLAN

PROJECT

NORTH

1/4" = 1'-0"

RM 5044 - FLOOR PLAN

1/4" = 1'-0"

RM 5044 - DEMO RCP

1/4" = 1'-0"

RM 5044 - RCP

PROJECT

NORTH

PROJECT

NORTH

PROJECT

NORTH

1. ALL PRODUCTS AND FINISHES SHALL MATCH EXISTING OR

ADJACENT EXISTING UNLESS OTHERWISE NOTED.

2. PATCH AND REPAIR WALLS, FLOORS AND CEILINGS

WHERE MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS

ARE DEMOLISHED.

3. PROTECT FINISHES IN ROOMS ADJACENT TO THE AREA OF

WORK AND PARTS THAT ARE NOT INCLUDED IN THE

SCOPE.

4. CONTRACTOR SHALL LEAVE FIRE RATING STAMP

UNPAINTED AND VISIBLE ON THE NEW INSTALLED FRT

PLYWOOD. SEE DETAIL 5/AE401.

5. REFER TO SHEET AS101 FOR ICRA REQUIREMENTS AND

DETAILS.

6. PATCH AND REPAIR CEILING, WALLS AND FLOORS AS

REQUIRED WHERE ICRA BARRIERS WILL BE CONSTRUCTED

AND REMOVED.

7. PATCH AND REPAIR GWB WHERE DOOR IS DEMOLISHED AND

A NEW DOOR WILL BE INSTALLED.

8. REFER TO SHEET A-602 FOR DOOR SCHEDULE.

9 INSTALL TEMPORARY 1 HR CONSTRUCTION ICRA BARRIER TO

SEPARATE CONSTRUCTION AREA FROM OCCUPIED SPACE.

10 INSTALL FIRE RESISTANT TEMPORARY SELF-CLOSING DOOR,

SOLID CORE WOOD IN STEEL FRAME, PAINTED, AT OPENING

AND MATCH RATING OF ICRA BARRIER, TYPICAL.

11 PLACE TACKY MATS AT ENTRANCE AND EXIT OF

CONSTRUCTION AREA, MINIMUM SIZE 24"x36", TYPICAL.

1 DEMOLISH EXISTING DOOR/FRAME. PREPARE FOR NEW

DOOR/FRAME.

2 PREPARE FLOORING FOR NEW WORK.

3 DEMOLISH EXISTING BASE. REMOVE EXISTING ADHESIVE AND

PREPARE FOR NEW BASE.

4 INSTALL NEW DOOR/FRAME.

5 APPLY ANTI-STATIC COATING TO EXPOSED FLOOR. PROVIDE

VINYL REDUCER STRIP AT EXISTING FLOORING TRANSITION.

6 INSTALL NEW RESILIENT RUBBER BASE AT ROOM PERIMETER

WITH SEALANT AT THE BOTTOM.

7 INFILL WALL, PATCH AND PAINT TO MATCH EXISTING.

8 INSTALL FRT PLYWOOD OVER WALLS AS NEEDED PER DETAIL

3/AE401, TYPICAL.

GENERAL NOTES

KEY PLAN

KEY NOTES (THIS SHEET ONLY)

LEGEND

TYPE III BARRIER WILL TEMPORARILY BLOCK

ACCESS TO RM 5042. COORDINATE WORK WITH

COR. BARRIER WILL ONLY BE IN PLACE DURING

DEMOLITION AND INSTALLATION OF NEW DOOR,

AND SHOULD BE IN PLACE FOR THE SHORTEST

PERIOD OF TIME POSSIBLE.

ICRA KEYNOTES

Revisions: Date:

ICRA CLASS III LEGEND

09/03/20259/3/2025 144 OF 693

ICRA CLASS III

ICRA CLASS IV

FIRE EXTINGUISHER CABINETFEC

FIRE EXTINGUISHERFE

ICRA CLASS II

2 HR FIRE RATED WALL

SMOKE RATED WALL

KEY AREA SHOWN

PROJECT

NORTH

A B C D E F G H I J K L M N O P

3.5

116 SF

COUNSEL

107 SF

COUNSEL

103 SF

COUNSEL

119 SF

COUNSEL

119 SF

COUNSEL

46 SF

STUDENT

65 SF

VESTIBULE

112 SF

PATIENT EDUC.

91 SF

MED.

53 SF

HSKPING

119 SF

COUNSEL

119 SF

COUNSEL

104 SF

COUNSEL

106 SF

COUNSEL

116 SF

COUNSEL

148 SF

STAIR 1

116 SF

COUNSEL

140 SF

TRIAGE

135 SF

TRIAGE

117 SF

COUNSEL

106 SF

WOMEN

111 SF

MEN

66 SF

VAPD OBSERVE

66 SF

VAPD

126 SF

COUNSEL

132 SF

COUNSEL

139 SF

COUNSEL

48 SF

STOR.

168 SF

ELEVATOR

LOBBY

48 SF

ELEV

116 SF

COUNSEL

399 SF

CORRIDOR

5100B

371 SF

WAITING

204 SF

MAIN ENTRANCE

LOBBY

176 SF

REGIST.

158 SF

WAITING

113 SF

STAIR 2

364 SF

CORRIDOR

5100A

386 SF

CORRIDOR

SECTION 1A:

CONTRACTOR TO COORDINATE WITH VA FOR ROOM CLOSURES

AND AVAILABILITY TO COMPLETE DATA WIRING IN THIS AREA.

SECTION 1B:

CONTRACTOR TO COORDINATE WITH VA FOR ROOM CLOSURES

AND AVAILABILITY TO COMPLETE DATA WIRING IN THIS AREA.

148 SF

STAIRS 3

5128B

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0

/2

:5

:5 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n

E H

R M

/B L

D G

.r v t

05AS101

BUILDING 05 - LEVEL 01 - PHASING PLAN

MA RB

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

KEY PLAN

LEGEND

PROJECT

NORTH

0' 2' 4' 8'3/16" = 1'-0"

BUILDING 05 - LEVEL 01 - PHASING PLAN

09/03/20259/3/2025 145 OF 693

ICRA CLASS III

ICRA CLASS IV

FIRE EXTINGUISHER CABINETFEC

FIRE EXTINGUISHERFE

ICRA CLASS II

2 HR FIRE RATED WALL

SMOKE RATED WALL

KEY AREA SHOWN

PROJECT

NORTH

A B C D E F G H I J K L M N O P

3.5

117 SF

COUNSEL

148 SF

STAIR 3

116 SF

COUNSEL

4244106 SF

COUNSEL

138 SF

COUNSEL

324 SF

CORRIDOR

5200B

133 SF

COUNSEL

123 SF

COUNSEL

115 SF

COUNSEL

128 SF

COUNSEL

130 SF

COUNSEL

102 SF

COUNSEL

131 SF

CORRIDOR

119 SF

COUNSEL

119 SF

COUNSEL

29 SF

HSKPING

38 SF

WOMEN

39 SF

MEN

91 SF

WORK RM

5222121 SF

COUNSEL

122 SF

RN OFFICE

192 SF

OFFICE

159 SF

CHIEF OFFICE

131 SF

OFFICE

164 SF

COMMON

93 SF

OFFICE

114 SF

COUNSEL

116 SF

COUNSEL

134 SF

COUNSEL

138 SF

COUNSEL

247 SF

CORRIDOR

123 SF

COUNSEL

118 SF

COUNSEL

111 SF

COUNSEL

110 SF

STAIR 2

48 SF

ELEV.

170 SF

LOBBY

51 SF

WAITING

270 SF

CORRIDOR

5200A

SECTION 1A:

CONTRACTOR TO COORDINATE WITH VA

FOR ROOM CLOSURES AND AVAILABILITY

TO COMPLETE DATA WIRING IN THIS AREA.

SECTION 1B:

CONTRACTOR TO COORDINATE WITH VA FOR ROOM

CLOSURES AND AVAILABILITY TO COMPLETE DATA

WIRING IN THIS AREA.

148 SF

STAIRS 1

5128C

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0

/2

:5

:5 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n

E H

R M

/B L

D G

.r v t

05AS102

BUILDING 05 - LEVEL 02 - PHASING PLAN

MA RB

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

KEY PLAN

LEGEND

PROJECT

NORTH

0' 2' 4' 8'3/16" = 1'-0"

BUILDING 05 - LEVEL 02 - PHASING PLAN

09/03/20259/3/2025 146 OF 693

NORTH

A

B C D E G H I J

548 SF

OCCUPATIONAL

THERAPY

172 SF

KITCHEN

12 SF

ELEC

82 SF

MECHANINCAL

143 SF

MECHANICAL

49 SF

WOMEN

49 SF

MEN

478 SF

MULTI PURPOSE

ROOM

174 SF

STORAGE

32 SF

CORRIDOR

41 SF

CORRIDOR

8 SF

MECH

6013A

46 SF

CORRIDOR

9 SF

MECH

6009A

28 SF

SPRINKLER

130 SF

STAIR

48 SF

ELEVATOR

6E1

243 SF

LOBBY

48 SF

ELEVATOR EQUIP

130 SF

STAIR

SECTION 1A:

CONTRACTOR TO COORDINATE WITH VA

FOR ROOM CLOSURES AND AVAILABILITY

TO COMPLETE DATA WIRING IN THIS AREA.

SECTION 1B:

CONTRACTOR TO COORDINATE WITH VA FOR

ROOM CLOSURES AND AVAILABILITY TO

COMPLETE DATA WIRING IN THIS AREA.

TR

ICRA PHASING LINE

ICRA CLASS III

ICRA CLASS IV

FIRE EXTINGUISHER CABINETFEC

FIRE EXTINGUISHERFE

ICRA CLASS II

1 HR FIRE RATED WALL

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0

/2

:5

:5 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n

E H

R M

/B L

D G

.r v t

06AS100

BUILDING 06 - LEVEL 00 - PHASING PLAN

MA CO/RB

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

KEY PLAN

LEGEND

1/4" = 1'-0"

BUILDING 06 - LEVEL 00 - PHASING PLAN

PROJECT

NORTH

0' 2' 4' 8'

09/03/20259/3/2025 147 OF 693

NORTH

A

B C D E G H I J

221 SF

SOUTH PORCH

268 SF

COMPENSATED

WORK THERAPY

177 SF

WAITING

96 SF

RECEPTION

186 SF

CORRIDOR

51 SF

WOMEN

51 SF

MEN

52 SF

HOUSEKEEP

130 SF

STAIR

130 SF

STAIR

291 SF

LOBBY

135 SF

TR

142 SF

EXAM

221 SF

NORTH PORCH

155 SF

RN

201 SF

GROUP

48 SF

ELEVATOR

PHASE 1:

CONTRACTOR TO COMPLETE THE WORK OF THIS

TR AND ASSOCIATED DATA DROPS. COMPLETE

ONE SECTION AT A TIME AS DIRECTED TO COR.

SECTION 1A:

CONTRACTOR TO COORDINATE WITH VA

FOR ROOM CLOSURES AND AVAILABILITY

TO COMPLETE DATA WIRING IN THIS AREA.

SECTION 1B:

CONTRACTOR TO COORDINATE WITH VA FOR

ROOM CLOSURES AND AVAILABILITY TO

COMPLETE DATA WIRING IN THIS AREA.

DIAMOND LINE

D

IA

M O

N D

L

IN

E

FEC

NEW SEMI-RECESSED FEC, TO MATCH

OR EXCEED EXISTING EXTINGUISHER IN

ABC RATING AND SIZE. SEE DET 4/A-604.

RM 6113

TR

ICRA PHASING LINE

ICRA CLASS III

ICRA CLASS IV

FIRE EXTINGUISHER CABINETFEC

FIRE EXTINGUISHERFE

ICRA CLASS II

1 HR FIRE RATED WALL

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0

/2

:5

:5 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n

E H

R M

/B L

D G

.r v t

06AS101

BUIL…

This is the start of the file's text. The full file is on GovTribe.