S02 - ATT 12 - 581-22-700 - 100 Drawings Part-10 of 24.pdf
PDF 19 MB Posted
- Solicitation number
- 36C77626R0025
About this file
This document is a set of 100% Construction Documents for the EHRM Infrastructure Upgrades project at VA Huntington, located at 1540 Spring Valley Drive, Huntington, WV 25704-9300. The construction documents comprise enlarged electrical plans for Buildings 01, 01S, 01W, 02, 03, 04, 05, 06, 07, and 08, prepared by SPEES Design Build with engineering discipline responsibility for mechanical, electrical, and building systems.
The electrical plans specify comprehensive infrastructure upgrades including data center grounding systems, power distribution modifications, transformer installations, panel upgrades, secondary bonding systems, telecommunications bonding, and lighting/receptacle installations across multiple levels and rooms in each building. Key technical requirements include grounding electrode system testing to verify 5-ohm resistance per IEEE 81 standards, telecommunications bonding per NEC and NFPA 780, conduit routing through rigid metallic conduit (RMC) where subject to physical damage, fire rating coordination for all penetrations, pull box provision for feeders exceeding 250 feet or 270 degrees of bend, and integration with existing mechanical systems. The project includes demolition and replacement of existing electrical equipment, preservation of branch circuits for re-termination, coordination of essential equipment power continuity during construction, and updated circuit panel directories. Construction is coordinated with multiple trades and VA phasing requirements, with all work subject to close coordination with contractor sequencing, architectural/structural considerations, and existing conditions verification.
View the file
Other files
Show 40 more
Latest 50 of 68 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AREA SHOWN
X Y Z
TELEPHONE
TERMINAL BOARDS
SURGE PROTECTION
MODULES
TELEPHONE
PUNCH BLOCKS
FIBERNET ISON CKT
UNIDENTIFIED EQUIPMENT
UNIDENTIFIED
PANEL
COMPUTER ALRMDATA RACK
TELECOM
DEVICES PATCH PANELS
QTY. (3)
EXISTING UPS
BATTERY
MANAGEMENT
SYSTEM
BMS
GC114
158 SF
DATA CENTER
GC115-1
1365 SF
ENTRANCE #1
158 SF
ELECTRICAL 1
165 SF CORRIDOR
549 SF
ENTRANCE #2
179 SF
MECH / FIRE
123 SF
ELECTRICAL 2
GC114a
143 SF
BATTERY
GC119
161 SF
TELE
GC118
243 SF
CLOSET 1
24 SF
CLOSET 2
19 SF
TYP.
EP504
CORRIDOR
549 SF
IRM MECH. SUPPORT
GC103
436 SF
XFMR 'ELA-G-LSA'
PANEL 'EPD-GESA'
A/C CONTROLLER
UPS BYPASS
PACS PANEL
DISC. XFMR 'ELA-G-LSA'
DATA RACK,
TYP.
ELEC
GC111
52 SF
WOMEN
GC109
146 SFMEN
GC108
173 SF
STAIR 9
207 SF
ELEV.
E-6
69 SF
ELEV.
E-5
69 SF
OXYGEN STOR
GC112
92 SF
STAIR 1
157 SF
LINEN
GB169
202 SF
MEN
GB174
51 SF
HAC
GB170
39 SF
GB173
19 SF
WOMEN
GB175
49 SF
ACCESS CONTROL
PANEL "01-ACP-GC115"
SECONDARY
BONDING
BUSBAR
BOND TO OVERHEAD
CABLE TRAY SECONDARY
BONDING BUSBAR
TO SHEET
01EG400Gg-2B
BOND TO OVERHEAD
CABLE TRAY
BMS PANEL
BOND TO OVERHEAD
CABLE TRAY
SECONDARY
BONDING BUSBAR
EP504
DATA CENTER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/0 /2
:0
:0 p m
B
IM
/5
-2
-7
V A
H u n t i n g to n E
H R
M /E
E
B L D
G
G R
O U
N D
F L
O O
R .r v t
01EG400Gf-2B
DATA CENTER - GROUNDING PLAN - PHASE 2B
(2 OF 2)
DCW/NVP RTS/JNV
100% CONSTRUCTION
DOCUMENTS
09/03/2025
581-22-700EHRM INFRASTRUCTURE
UPGRADES - HUNTINGTON
VA HUNTINGTON
1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300
KEY PLAN
GENERAL NOTES
KEY NOTES
2'0 4' 8'
PROJECT
NORTH
PROJECT
NORTH
1/4" = 1'-0"01EP100G
1 DATA CENTER - GROUNDING PLAN - PHASE 2B (2 OF 2)
Revisions: Date:
REFERENCE TR TOWER 1 ENLARGED PLANS FOR WORK TO BE PERFORMED.
PROVIDE BONDING AND CONDUCTOR TO EXTEND TELECOMMUNICATIONS
EQUIPMENT BONDING.
PROVIDE SBC AS INDICATED; WHERE CONDUCTOR IS SUBJECT TO PHYSICAL
DAMAGE, CONDUCTOR SHALL BE ROUTED THROUGH RMC. REFERENCE
TELECOMMUNICATIONS BONDING RISER DIAGRAM ON SHEET EG601 FOR ADDITIONAL
INFORMATION.
RELOCATED SBB. REFERENCE SHEET 01EG400Ge-2B FOR ADDITIONAL INFORMATION.
PROVIDE BONDING AS REQUIRED.
PROVIDE SBC AS INDICATED; WHERE CONDUCTOR IS SUBJECT TO PHYSICAL
DAMAGE, CONDUCTOR SHALL BE ROUTED THROUGH RMC. REFERENCE
TELECOMMUNICATIONS BONDING RISER DIAGRAM ON SHEET EG601 FOR ADDITIONAL
INFORMATION.
PROVIDE BOND TO ELECTRO-STATIC DISCHARGE FLOORING. BONDING CONDUCTOR
SHALL BE 12 AWG MIN; PROVIDE AND INSTALL PER MANUFACTURER'S
INSTRUCTIONS.
PROVIDE SECONDARY BONDING BUSBAR. REFERENCE TELECOMMUNICATIONS
BONDING RISER DIAGRAM ON SHEET EG601 FOR ADDITIONAL INFORMATION.
1. ALL ELECTRICAL WORK SHALL BE CLOSELY COORDINATED WITH THE CONTRACTORS
PHASING OF THE PROJECT. COORDINATE ALL ELECTRICAL WORK WITH ALL OTHER
TRADES.
2. MAKE ALL CONNECTIONS TO EQUIPMENT PER MANUFACTURER'S REQUIREMENTS.
3. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO MATCH EXISTING FIRE
RATING OR NEW FIRE RATING; PROVIDE CORE DRILLING AS REQUIRED. COORDINATE
WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS AS REQUIRED.
4. REFERENCE CORRESPONDING ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION.
5. NOT ALL GROUNDING AND BONDING MAY BE SHOWN FO DRAWING CLARITY
PURPOSES. ALL BONDING AND GROUNDING SHALL ADHERE TO NEC AND NFPA780.
REFERENCE GORUNDING AND BONDING DETAILS FOR ADDITIONAL INFORMATION.
6. CONTRACTOR SHALL TEST DATA CENTER GROUNDING ELECTRODE SYSTEM TO
VERIFY GROUNDING SYSTEM'S RESISTANCE-TO-EARTH IS 5 Ω OR LESS AS
MEASURED BY THE FOUR-POINT FALL-OF-POTENTIAL METHOD AS PRESCRIBED BY
IEEE 81.
7. FOR ALL TELECOMMUNICATIONS BONDING CONNECTIONS, REFERENCE
TELECOMMUNICATIONS BONDING RISER DIAGRAM ON SHEET EG601.
A
A
A
A
A
A
B
B
B
B
B
B
A
A
A
A
B B B B B B
A A
B B
A A
B B
AREA SHOWN
A16
1-EDPA-G-ESA
ATS '1_TS1ES'
1-EDPA-G-A
1-DPA-G-LSA
XFMR
1-DLA-G-A
1-G-MDP
1-DPA-G-A
ATS '1_TS1CB'
1-EDPA-G-CBA
143 SF
ELEC
GC121
A16
1-EDPA-G-ESA
ATS '1_TS1ES'
1-EDPA-G-A
ATS '1_TS1LSB'
1-DPA-G-LSA
XFMR
1-DLA-G-A
1-G-MDP
1-DPA-G-A
01-P-08
TO SHEET 01EP100G
01-P-04 01-P-01
01-P-02
DPM (ABOVE)
SPD (BELOW)
1-EDPA-G-CBA
01-P-09 01-P-03
RM GC121
143 SF
ELEC
GC121
A SIDE POWER, CONCEALED WHERE POSSIBLE
B SIDE POWER, CONCEALED WHERE POSSIBLE
A SIDE POWER, UNDERGROUND / UNDERFLOOR
B SIDE POWER, UNDERGROUND / UNDERFLOOR
PROVIDED TO INDICATE 'A' AND 'B' SIDE SOURCED POWER FEEDERS.
REFERENCE GENERAL SYMBOL LEGEND FOR ADDITIONAL
INFORMATION.
LEGEND
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/0
/2
:4
:4 a m
B
IM
/5
-2
-7
V A
H u n t i n g to n E
H R
M /E
E
B L D
G
G R
O U
N D
F L
O O
R .r v t
01EP400Gr
BLDG 01 - LEVEL 00G - ENLARGED
ELECTRICAL PLANS
DCW/NVP RTS/JNV
100% CONSTRUCTION
DOCUMENTS
09/03/2025
581-22-700EHRM INFRASTRUCTURE
UPGRADES - HUNTINGTON
VA HUNTINGTON
1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300
PROJECT
NORTH
GENERAL NOTES
KEY PLAN
KEY NOTES
1. DEMOLITION PLANS/NOTES ARE BASED ON SITE INVESTIGATIONS AND RECORD
DRAWINGS. IF DISCREPANCIES ARE FOUND THAT MAY IMPACT WORK, PROMPTLY
NOTIFY VA AND ENGINEER OF SAID DISCREPANCY.
2. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR CLARITY. CONTRACTOR SHALL
FIELD VERIFY ALL POWER, LIGHTING AND ASSOCIATED CIRCUITRY AS REQUIRED. ALL
RACEWAYS AND CONDUCTORS ASSOCIATED WITH EQUIPMENT TO BE DEMOLISHED
SHALL BE DEMOLISHED BACK TO THEIR SOURCE, UNLESS OTHERWISE NOTED.
3. CONTRACTOR SHALL DEMOLISH ALL ELECTRICAL EQUIPMENT, CONDUCTORS AND
RACEWAYS ASSOCIATED WITH WALLS BEING REMOVED, AND IN ALL LOCATIONS
WHERE JUNCTION BOXES WILL NOT REMAIN ACCESSIBLE AFTER INSTALLATION,
UNLESS OTHERWISE NOTED.
4. CONTRACTOR SHALL COORDINATE NORMAL/ESSENTIAL ELECTRICAL SYSTEM
SHUTDOWNS AND PHASING WITH THE VA PRIOR TO PERFORMING REQUIRED
EQUIPMENT UPGRADES. CONTRACTOR TO PROVIDE BACKUP EMERGENCY POWER
AND DETERMINE TIE-IN/CONNECTION PLAN WITH EXISTING EQUIPMENT. POWER TO
ALL EXISTING ESSENTIAL EQUIPMENT CANNOT BE INTERRUPTED AND SHALL REMAIN
ACTIVE DURING CONSTRUCTION. BACKUP POWER AND TIE-IN SHALL CONFORM WITH
VA STANDARDS.
5. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO MATCH EXISTING FIRE
RATING OR NEW FIRE RATING; PROVIDE CORE DRILLING AS REQUIRED. COORDINATE
WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS AS REQUIRED.
6. REFERENCE CORRESPONDING ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION.
7. CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT PANEL DIRECTORIES FOR ALL
PANELS THAT CONTAIN CIRCUITS IMPACTED BY THIS PROJECT.
8. CONTRACTOR SHALL PROVIDE PULL BOXES FOR ALL FEEDERS WHERE FEEDER RUNS
EXCEED 250FT OR HAVE MORE THAN 270 DEGREES OF TOTAL BEND. PULL BOX
PLACEMENT AND SIZING BY CONTRACTOR. COORDINATE PULL BOX LOCATIONS WITH
ALL OBSTRUCTIONS, TRADES, AND VA AS REQUIRED.
9. ALL RECEPTACLES AND SWITCHES SHALL BE PROVIDED WITH PANEL AND CIRCUIT
LABELING LOCATED DIRECTLY ON THE WALL PLATE; IE:"P4-1", PANEL "4", CIRCUIT "1".
REFERENCE WIRING DEVICE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
1/2" = 1'-0"01EP100G
1 RM GC121 - DEMOLITION ELECTRICAL PLAN 1'0 2' 4'
PROJECT
NORTH
1/2" = 1'-0"01EP100G
2 RM GC121 - ELECTRICAL PLAN 1'0 2' 4'
PROJECT
NORTH
EXISTING EQUIPMENT SHALL BE DEMOLISHED. ASSOCIATED CONDUIT AND WIRE
SHALL BE DEMOLISHED BACK TO SOURCE.
EXISTING PANELBOARD SHALL BE DEMOLISHED AND REPLACED AS INDICATED.
PRESERVE AND PROTECT EXISTING BRANCH CIRCUITS FOR RE-TERMINATION TO
REVISED EQUIPMENT; PROVIDE JUNCTION BOXES (QUANTITY AS REQUIRED) TO
HOUSE CONDUCTOR TERMINATIONS. SIZE JUNCTION BOXES PER NEC. COORDINATE
FINAL JUNCTION BOX LOCATIONS WITH EXISTING CONDITIONS AND EQUIPMENT AS
REQUIRED. REFERENCE ASSOCIATED ONE-LINE DIAGRAMS FOR ADDITIONAL
INFORMATION.
DEMOLISH EXISTING CONDUIT AND RACEWAYS IN ITS ENTIRETY.
EXISTING EQUIPMENT SHALL BE MODIFIED. REFERENCE ASSOCIATED BUILDING '01'
ONE-LINE DIAGRAMS FOR ADDITIONAL INFORMAITON.
Revisions: Date:
3TYP.
A
A
A
A
A
B
B
B
B
B
B
B
B
B A
A
A
A
A
A
A
A
AAAAAAA
A
A
AAAAAAAA
BBBBBBB
AAAAAAA
AAAAAAA
A
A
A A
A
A
A
A
A
A
A
A
A
A
A
A
A
AAAAAAA
EP506
AAAAAAA
A A
B B
A A
B B
AREA SHOWN
1W_CPGB-2
1W_CPGB-1
1W_LSGB
HOUSEKEEPING PAD
XFMR '1W_CGB'1
DISCONNECT
"XFMR CGB"
108 SF
ELEC/IRM
GC127
XFMR '1W_CGB'
(ABOVE)
1W_CPGB-2
1W_CPGB-1
1W_LSGB
ATS '1_TS1CB'
01-P-03
01-P-01
01-P-04
01-P-05
TRANSFORMER 'XFMR-1S-TWR1-A' (BELOW)
ENCLOSED CIRCUIT BREAKER
"ECB-XFMR-1S-TWR1-A"
01-P-02
01S-PA-10A
HOUSEKEEPING
PAD
HOUSEKEEPING
PAD
DISCONNECT
"XFMR CGB"
01W-P-17
01W-P-16
108 SF
ELEC/IRM
GC127
RM GC127
A SIDE POWER, CONCEALED WHERE POSSIBLE
B SIDE POWER, CONCEALED WHERE POSSIBLE
A SIDE POWER, UNDERGROUND / UNDERFLOOR
B SIDE POWER, UNDERGROUND / UNDERFLOOR
PROVIDED TO INDICATE 'A' AND 'B' SIDE SOURCED POWER FEEDERS.
REFERENCE GENERAL SYMBOL LEGEND FOR ADDITIONAL
INFORMATION.
LEGEND
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/0
/2
:4
:5 a m
B
IM
/5
-2
-7
V A
H u n t i n g to n E
H R
M /E
E
B L D
G
G R
O U
N D
F L
O O
R .r v t
01EP400Gs
BLDG 01 - LEVEL 00G - ENLARGED
ELECTRICAL PLANS
DCW/NVP RTS/JNV
100% CONSTRUCTION
DOCUMENTS
09/03/2025
581-22-700EHRM INFRASTRUCTURE
UPGRADES - HUNTINGTON
VA HUNTINGTON
1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300
PROJECT
NORTH
GENERAL NOTES
KEY PLAN
KEY NOTES
1. DEMOLITION PLANS/NOTES ARE BASED ON SITE INVESTIGATIONS AND RECORD
DRAWINGS. IF DISCREPANCIES ARE FOUND THAT MAY IMPACT WORK, PROMPTLY
NOTIFY VA AND ENGINEER OF SAID DISCREPANCY.
2. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR CLARITY. CONTRACTOR SHALL
FIELD VERIFY ALL POWER, LIGHTING AND ASSOCIATED CIRCUITRY AS REQUIRED. ALL
RACEWAYS AND CONDUCTORS ASSOCIATED WITH EQUIPMENT TO BE DEMOLISHED
SHALL BE DEMOLISHED BACK TO THEIR SOURCE, UNLESS OTHERWISE NOTED.
3. CONTRACTOR SHALL DEMOLISH ALL ELECTRICAL EQUIPMENT, CONDUCTORS AND
RACEWAYS ASSOCIATED WITH WALLS BEING REMOVED, AND IN ALL LOCATIONS
WHERE JUNCTION BOXES WILL NOT REMAIN ACCESSIBLE AFTER INSTALLATION,
UNLESS OTHERWISE NOTED.
4. CONTRACTOR SHALL COORDINATE NORMAL/ESSENTIAL ELECTRICAL SYSTEM
SHUTDOWNS AND PHASING WITH THE VA PRIOR TO PERFORMING REQUIRED
EQUIPMENT UPGRADES. CONTRACTOR TO PROVIDE BACKUP EMERGENCY POWER
AND DETERMINE TIE-IN/CONNECTION PLAN WITH EXISTING EQUIPMENT. POWER TO
ALL EXISTING ESSENTIAL EQUIPMENT CANNOT BE INTERRUPTED AND SHALL REMAIN
ACTIVE DURING CONSTRUCTION. BACKUP POWER AND TIE-IN SHALL CONFORM WITH
VA STANDARDS.
5. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO MATCH EXISTING FIRE
RATING OR NEW FIRE RATING; PROVIDE CORE DRILLING AS REQUIRED. COORDINATE
WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS AS REQUIRED.
6. REFERENCE CORRESPONDING ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION.
7. CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT PANEL DIRECTORIES FOR ALL
PANELS THAT CONTAIN CIRCUITS IMPACTED BY THIS PROJECT.
8. CONTRACTOR SHALL PROVIDE PULL BOXES FOR ALL FEEDERS WHERE FEEDER RUNS
EXCEED 250FT OR HAVE MORE THAN 270 DEGREES OF TOTAL BEND. PULL BOX
PLACEMENT AND SIZING BY CONTRACTOR. COORDINATE PULL BOX LOCATIONS WITH
ALL OBSTRUCTIONS, TRADES, AND VA AS REQUIRED.
9. ALL RECEPTACLES AND SWITCHES SHALL BE PROVIDED WITH PANEL AND CIRCUIT
LABELING LOCATED DIRECTLY ON THE WALL PLATE; IE:"P4-1", PANEL "4", CIRCUIT "1".
REFERENCE WIRING DEVICE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
1/2" = 1'-0"01EP100G
1 RM - GC127 - DEMOLITION ELECTRICAL PLAN 1'0 2' 4'
PROJECT
NORTH
1'0 2' 4'
PROJECT
NORTH
1/2" = 1'-0"01EP100G
2 RM - GC127 - ELECTRICAL PLAN
EXISTING TRANSFORMER "1W-CPCB" SHALL BE RELOCATED.
EXISTING TRANSFORMER "1W-CPCB" RELOCATED ABOVE PROVIDED TRANSFORMER.
REFERENCE DETAIL '2' ON SHEET EP506 FOR TYPICAL MOUNTING DETAILS.
EXTEND EXISTING HOUSEKEEPING PAD AS REQUIRED. REFERENCE KEYNOTE 4 ON
THIS SHEET FOR MORE INFORMATION.
HOUSEKEEPING PAD, 3-1/2" WITH CHAMFERED EDGE, SIZE PER EQUIPMENT FOOT
PRINT. PROVIDE 5000PSI CONCRETE WITH #4 REBAR, 12" OC, REBAR SHALL BE TIED,
COORDINATE REBAR INSTALLATION WITH CONDUIT INSTALLATIONS AS REQUIRED.
EXISTING CONDUIT AND WIRE SHALL BE DEMOLISHED AS INDICATED.
PROVIDE REPLACEMENT CONDUIT AND WIRE TO SERVE EXISTING EQUIPMENT AS
INDICATED.
Revisions: Date:
A
A
A
A
A
A
A
A
A
B
B
B
B
B
B
B
B
B
A A A
A A A A A A A A A A A A A A A A A A A A A A A A A A A A
AA
AA
B
B
B
B
B
B
B
B
BBBBBBB
BBBBBBB
AA
A A A
B B
B
B
B
B
B
B
B
B
B
B
B B
A A A A
AAA
BBBBBBB
BBBBBBB
BBB
A A
B B
A A
B B
AREA SHOWN
J K L M
SUBSTAT 4
SUBSTAT 5
XFMR-1S-TWR4A
01S-PA-01
EP504
01S-PA-20
DISCONNECT
MTS-1
VFD '15-C13'
MCC-EBB
AUMAUM
CHILLER MTS
ATS-EE
ATS-TE
ATS-SE
ATS-XC
ATS-LS
ATS-1
MCC-NBB VFD 'C12'
ATS-CEM
XFMR "XFMR-1S-TWR4B"
PANEL "1S-MDP-DC-TR-B"
ATS-CEM 1S-AHU-16 DISC.
1S-SGCP-ES
ATS-STANDBY/PREFERRED
PANEL '1S-RPS-BB'
PANEL '1S-MDP-LS'
PANEL '1S_MDP-CE'
01S-PB-02
01S-PB-01
TO SHEET 01SEP100B
01S-PB-03B
01S-P-DCB
01S-P-DCA
01S-PA-02B
01S-PB-19
HOUSEKEEPING PAD6
HOUSEKEEPING PAD 6
01S-PA-19
1S_ATS-CE
EMERG.
GENERATOR
BB115
699 SF
ELECTRICAL
SWITCH
BB116
1384 SF
01S-PA-02A
ENCLOSED CIRCUIT BREAKER
"ECB-XFMR-1S-TWR4A"
PRIMARY BONDING
BUSBAR (PBB)
01S-PB-03A
ENCLOSED CIRCUIT
BREAKER
"ECB-XFMR-1S-TWR4B"
J K L M
DISCONNECT
MTS-1
VFD '15-C13'
MCC-EBB
AUMAUM
CHILLER MTS
ATS-EE
ATS-TE
ATS-SE
ATS-XC
ATS-CE ATS-LS
ATS-1
MCC-NBB
VFD 'C12'
ATS-CEM
ATS-CEM 1S-AHU-16 DISC.
1S-SGCP-ES
ATS-STANDBY/PREFERRED
PANEL '1S-RPS-BB'
PANEL '1S-MDP-LS'
PANEL '1S_MDP-CE'
SUBSTAT 4
SUBSTAT 5
4 1
EMERG.
GENERATOR
BB115
699 SF
ELECTRICAL
SWITCH
BB116
1384 SF
BB115 & BB116
A SIDE POWER, CONCEALED WHERE POSSIBLE
B SIDE POWER, CONCEALED WHERE POSSIBLE
A SIDE POWER, UNDERGROUND / UNDERFLOOR
B SIDE POWER, UNDERGROUND / UNDERFLOOR
PROVIDED TO INDICATE 'A' AND 'B' SIDE SOURCED POWER FEEDERS.
REFERENCE GENERAL SYMBOL LEGEND FOR ADDITIONAL
INFORMATION.
LEGEND
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/0
/2
:4
:2 a m
B
IM
/5
-2
-7
V A
H u n t i n g to n E
H R
M /E
E
B L D
G
B A
S E
M E
N T
.r v t
01SEP400Ba
BLDG 01S - LEVEL 00B - ENLARGED
ELECTRICAL PLANS
01S
DCW/NVP RTS/JNV
100% CONSTRUCTION
DOCUMENTS
09/03/2025
581-22-700EHRM INFRASTRUCTURE
UPGRADES - HUNTINGTON
VA HUNTINGTON
1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300
KEY PLAN
GENERAL NOTES
PROJECT
NORTH
EXISTING EQUIPMENT SHALL BE DEMOLISHED. ASSOCIATED CONDUIT AND WIRE
SHALL BE DEMOLISHED BACK TO SOURCE UNLESS OTHERWISE NOTED.
EXISTING CONDUCTORS SHALL BE DEMOLISHED. EXISTING CONDUIT SHALL REMAIN.
PROVIDE TBB AS INDICATED; WHERE CONDUCTOR IS SUBJECT TO PHYSICAL
DAMAGE, CONDUCTOR SHALL BE ROUTED THROUGH RMC. REFERENCE
TELECOMMUNICATIONS BONDING RISER DIAGRAM ON SHEET EG601 FOR ADDITIONAL
INFORMATION.
EXISTING PANELBOARD SHALL BE DEMOLISHED AND REPLACED AS INDICATED.
PRESERVE AND PROTECT EXISTING BRANCH CIRCUITS FOR RE-TERMINATION TO
REVISED EQUIPMENT; PROVIDE JUNCTION BOXES (QUANTITY AS REQUIRED) TO
HOUSE CONDUCTOR TERMINATIONS. SIZE JUNCTION BOXES PER NEC. COORDINATE
FINAL JUNCTION BOX LOCATIONS WITH EXISTING CONDITIONS AND EQUIPMENT AS
REQUIRED. REFERENCE ASSOCIATED ONE-LINE DIAGRAMS FOR ADDITIONAL
INFORMATION.
PROVIDE TBC AS SHOWN. REFERENCE TELECOM BONDING RISER DIAGRAMS ON
SHEET EG601 FOR ADDITIONAL INFORMATION.
PRIMARY BONDING BUSBAR. REFERENCE TELECOMMUNICATIONS BONDING RISER
DIAGRAM ON SHEET EG601 FOR BONDING JUMPER AND CONNECTION
REQUIREMENTS.
EXISTING EQUIPMENT SHALL BE MODIFIED. REFERENCE ASSOCIATED BUILDING '01S'
ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION.
HOUSEKEEPING PAD, 3-1/2" WITH CHAMFERED EDGE, SIZE PER EQUIPMENT FOOT
PRINT. PROVIDE 5000PSI CONCRETE WITH #4 REBAR, 12" OC, REBAR SHALL BE TIED,
COORDINATE REBAR INSTALLATION WITH CONDUIT INSTALLATIONS AS REQUIRED.
EXISTING UNDERGROUND CONDUIT PENETRATIONS SHALL REMAIN AND BE CAPPED
AND ABANDONED.
EXISTING FURNITURE SHALL BE RELOCATED PER VA DIRECTION.
KEY NOTES
1. DEMOLITION PLANS/NOTES ARE BASED ON SITE INVESTIGATIONS AND RECORD
DRAWINGS. IF DISCREPANCIES ARE FOUND THAT MAY IMPACT WORK, PROMPTLY
NOTIFY VA AND ENGINEER OF SAID DISCREPANCY.
2. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR CLARITY. CONTRACTOR SHALL
FIELD VERIFY ALL POWER, LIGHTING AND ASSOCIATED CIRCUITRY AS REQUIRED.
ALL RACEWAYS AND CONDUCTORS ASSOCIATED WITH EQUIPMENT TO BE
DEMOLISHED SHALL BE DEMOLISHED BACK TO THEIR SOURCE, UNLESS
OTHERWISE NOTED.
3. CONTRACTOR SHALL DEMOLISH ALL ELECTRICAL EQUIPMENT, CONDUCTORS AND
RACEWAYS ASSOCIATED WITH WALLS BEING REMOVED, AND IN ALL LOCATIONS
WHERE JUNCTION BOXES WILL NOT REMAIN ACCESSIBLE AFTER INSTALLATION,
UNLESS OTHERWISE NOTED.
4. CONTRACTOR SHALL COORDINATE NORMAL/ESSENTIAL ELECTRICAL SYSTEM
SHUTDOWNS AND PHASING WITH THE VA PRIOR TO PERFORMING REQUIRED
EQUIPMENT UPGRADES. CONTRACTOR TO PROVIDE BACKUP EMERGENCY POWER
AND DETERMINE TIE-IN/CONNECTION PLAN WITH EXISTING EQUIPMENT. POWER TO
ALL EXISTING ESSENTIAL EQUIPMENT CANNOT BE INTERRUPTED AND SHALL
REMAIN ACTIVE DURING CONSTRUCTION. BACKUP POWER AND TIE-IN SHALL
CONFORM WITH VA STANDARDS.
5. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO MATCH EXISTING FIRE
RATING OR NEW FIRE RATING; PROVIDE CORE DRILLING AS REQUIRED.
COORDINATE WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS AS REQUIRED.
6. REFERENCE CORRESPONDING ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION.
7. CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT PANEL DIRECTORIES FOR ALL
PANELS THAT CONTAIN CIRCUITS IMPACTED BY THIS PROJECT.
8. CONTRACTOR SHALL PROVIDE PULL BOXES FOR ALL FEEDERS WHERE FEEDER
RUNS EXCEED 250FT OR HAVE MORE THAN 270 DEGREES OF TOTAL BEND. PULL
BOX PLACEMENTS AND SIZING BY CONTRACTOR. COORDINATE PULL BOX
LOCATIONS WITH ALL OBSTRUCTIONS, TRADES, AND VA AS REQUIRED.
9. ALL RECEPTACLES AND SWITCHES SHALL BE PROVIDED WITH PANEL AND CIRCUIT
LABELING LOCATED DIRECTLY ON THE WALL PLATE; IE:"P4-1", PANEL "4", CIRCUIT
"1". REFERENCE WIRING DEVICE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
1/4" = 1'-0"01SEP100B
2 RM BB115 AND BB116 - ELECTRICAL PLAN
1/4" = 1'-0"01SEP100B
1 RM BB115 AND BB116 - DEMOLITION ELECTRICAL PLAN 2'0 4' 8'
PROJECT
NORTH
2'0 4' 8'
PROJECT
NORTH
Revisions: Date:
WORK TABLE
J
BBBBBBB
B
B
B
B
B
AA
A
A
A
A
BBBBBBB
BBBBBBBBBB
EP502
AA
A A A A A A A A A
Mo
A A
B B
A A
B B
AREA SHOWN
V
TYP.
V
EP504
01-VRF-02-BB100B-1S
01S-BB100B-1SB
01S-BB100B-1SA
01-VRF-01-BB100B-1S
ACCESS CONTROL PANEL
"01S-ACP-01S-BB100B-1S"
01S-BB100B-1SA-25
TR
BB100B-1S
106 SF
C
C
P-TR-1B
P-TR-1A
01S-PA-11
01S-PB-12
01S-BB100B-1SA-25
FROM 01SEP100B
FROM 01SEP100B
01S-BB100B-1SA-7,9
01S-BB100B-1SA-11,13
V
TYP.
V
01S-BB100B-1SB
01S-BB100B-1SA
L5
L5 L5
L5
TR
BB100B-1S
106 SF
TYP.
EP508
EP508
01S-BB100B-1SA-4
NIC
475 SF
IRM STORAGE
475 SF
IRM STORAGE
BB100B-1S
A SIDE POWER, CONCEALED WHERE POSSIBLE
B SIDE POWER, CONCEALED WHERE POSSIBLE
A SIDE POWER, UNDERGROUND / UNDERFLOOR
B SIDE POWER, UNDERGROUND / UNDERFLOOR
PROVIDED TO INDICATE 'A' AND 'B' SIDE SOURCED POWER FEEDERS.
REFERENCE GENERAL SYMBOL LEGEND FOR ADDITIONAL
INFORMATION.
LEGEND
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/0
/2
:4
:3 a m
B
IM
/5
-2
-7
V A
H u n t i n g to n E
H R
M /E
E
B L D
G
B A
S E
M E
N T
.r v t
01SEP400Bb
BLDG 01S - LEVEL 00B - ENLARGED
ELECTRICAL PLANS
01S
DCW/NVP RTS/JNV
100% CONSTRUCTION
DOCUMENTS
09/03/2025
581-22-700EHRM INFRASTRUCTURE
UPGRADES - HUNTINGTON
VA HUNTINGTON
1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300
KEY PLAN
GENERAL NOTES
PROJECT
NORTH
1/2" = 1'-0"01SEP100B
1 RM BB100B-1S - DEMOLITION ELECTRICAL PLAN
1/2" = 1'-0"01SEP100B
2 RM BB100B-1S - ELECTRICAL PLAN1'0 2' 4'
PROJECT
NORTH
1/2" = 1'-0"01SEP100B
3 RM BB100B-1S - DEMOLITION LIGHTING PLAN
1/2" = 1'-0"01SEP100B
4 RM BB100B-1S - LIGHTING AND RECEPTACLE PLAN
1'0 2' 4'
PROJECT
NORTH
1'0 2' 4'
PROJECT
NORTH
1'0 2' 4'
PROJECT
NORTH
EXISTING EQUIPMENT SHALL BE DEMOLISHED. ASSOCIATED CONDUIT AND WIRE
SHALL BE DEMOLISHED BACK TO SOURCE.
SOURCE A POWER PANELBOARD "01S-BB100B-1SA".
SOURCE B POWER PANELBOARD "01S-BB100B-1SB".
PROVIDE SECONDARY BONDING BUSBAR. REFERENCE TELECOMMUNICATIONS
BONDING RISER DIAGRAM(S) FOR ADDITIONAL INFORMATION.
OVERHEAD TR RACK SOURCE A AND SOURCE B POWER RECEPTACLE.
FURNISH AND INSTALL BOXED POWER SUPPLIES AS INDICATED ABOVE
ACCESSIBLE CEILINGS. VERIFY LOCATIONS WITH ARCHITECT. PROVIDE (1) POWER
SUPPLY FOR EACH DOOR OPENING. PROVIDE 120V POWER TO ADEQUATELY SERVE
DOORS WITH ELECTRIFIED DOOR HARDWARE AND MAKE CONNECTIONS AS
REQUIRED. SEE REQUIREMENTS IN "08 71 00 - DOOR HARDWARE". COORDINATE WITH
ARCHITECT AND DOOR INSTALLER.
PROVIDE RACEWAYS AND CONDUCTORS PER MANUFACTURER'S REQUIREMENTS.
REFERENCE MECHANICAL DRAWINGS AND COORDINATE WITH MECHANICAL
CONTRACTOR AS REQUIRED.
EXISTING ROOM LIGHTING SHALL BE MODIFIED. ENSURE REMAINING LIGHTING
WITHIN ROOM MAINTAINS POWER AND CONTROL VIA EXTENDING EXISTING
CIRCUITRY AND MODIFYING ASSOCIATED RACEWAYS AND CONDUCTORS AS
REQUIRED.
TELECOM RACK IS NIC PER DESIGN ALERT 16. SPARE CIRCUIT BREAKER HAS BEEN
PROVIDED FOR FUTURE EQUIPMENT. REFERENCE ASSOCIATED PANEL SCHEDULES
FOR ADDITIONAL INFORMATION.
PROVIDE SBC AS INDICATED; WHERE CONDUCTOR IS SUBJECT TO PHYSICAL
DAMAGE, CONDUCTOR SHALL BE ROUTED THROUGH RMC. REFERENCE
TELECOMMUNICATIONS BONDING RISER DIAGRAM ON SHEET EG601 FOR ADDITIONAL
INFORMATION.
KEY NOTES
Revisions: Date:
1. DEMOLITION PLANS/NOTES ARE BASED ON SITE INVESTIGATIONS AND RECORD
DRAWINGS. IF DISCREPANCIES ARE FOUND THAT MAY IMPACT WORK, PROMPTLY
NOTIFY VA AND ENGINEER OF SAID DISCREPANCY.
2. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR CLARITY. CONTRACTOR SHALL
FIELD VERIFY ALL POWER, LIGHTING AND ASSOCIATED CIRCUITRY AS REQUIRED.
ALL RACEWAYS AND CONDUCTORS ASSOCIATED WITH EQUIPMENT TO BE
DEMOLISHED SHALL BE DEMOLISHED BACK TO THEIR SOURCE, UNLESS
OTHERWISE NOTED.
3. CONTRACTOR SHALL DEMOLISH ALL ELECTRICAL EQUIPMENT, CONDUCTORS AND
RACEWAYS ASSOCIATED WITH WALLS BEING REMOVED, AND IN ALL LOCATIONS
WHERE JUNCTION BOXES WILL NOT REMAIN ACCESSIBLE AFTER INSTALLATION,
UNLESS OTHERWISE NOTED.
4. CONTRACTOR SHALL COORDINATE NORMAL/ESSENTIAL ELECTRICAL SYSTEM
SHUTDOWNS AND PHASING WITH THE VA PRIOR TO PERFORMING REQUIRED
EQUIPMENT UPGRADES. CONTRACTOR TO PROVIDE BACKUP EMERGENCY POWER
AND DETERMINE TIE-IN/CONNECTION PLAN WITH EXISTING EQUIPMENT. POWER TO
ALL EXISTING ESSENTIAL EQUIPMENT CANNOT BE INTERRUPTED AND SHALL
REMAIN ACTIVE DURING CONSTRUCTION. BACKUP POWER AND TIE-IN SHALL
CONFORM WITH VA STANDARDS.
5. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO MATCH EXISTING FIRE
RATING OR NEW FIRE RATING; PROVIDE CORE DRILLING AS REQUIRED.
COORDINATE WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS AS REQUIRED.
6. REFERENCE CORRESPONDING ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION.
7. CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT PANEL DIRECTORIES FOR ALL
PANELS THAT CONTAIN CIRCUITS IMPACTED BY THIS PROJECT.
8. CONTRACTOR SHALL PROVIDE PULL BOXES FOR ALL FEEDERS WHERE FEEDER
RUNS EXCEED 250FT OR HAVE MORE THAN 270 DEGREES OF TOTAL BEND. PULL
BOX PLACEMENTS AND SIZING BY CONTRACTOR. COORDINATE PULL BOX
LOCATIONS WITH ALL OBSTRUCTIONS, TRADES, AND VA AS REQUIRED.
9. ALL RECEPTACLES AND SWITCHES SHALL BE PROVIDED WITH PANEL AND CIRCUIT
LABELING LOCATED DIRECTLY ON THE WALL PLATE; IE:"P4-1", PANEL "4", CIRCUIT
"1". REFERENCE WIRING DEVICE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
B
B
B
B
B
B
B
B
B B B
B
B
B
BB
B
B
B
B
B
BBBBBBB
A A
B B
A A
B B
AREA SHOWN
X
PANEL 'RPS-BC'
PANEL 'RPN-BC'
PANEL 'LPN-BC'
VSS-2-L-3-B
PANEL 'LPS-BC'
X
PANEL 'LPN-BC'
PANEL 'RPN-BC'
PANEL 'RPS-BC'
VSS-2-L-3-B
PANEL 'LPS-BC'
ELEC
BB110D
64 SF
TRANSFORMER "1S-TWR1B"
ENCLOSED CIRCUIT BREAKER
"ECB-1S-TWR1B"
TO SHEET
01SEP100B
FROM SHEET 01SEP100B
01S-PB-10A
01S-PB-11A
HOUSEKEEPING PAD
01S-PB-10B
ELEC
BB110D
64 SF
BB110D
A SIDE POWER, CONCEALED WHERE POSSIBLE
B SIDE POWER, CONCEALED WHERE POSSIBLE
A SIDE POWER, UNDERGROUND / UNDERFLOOR
B SIDE POWER, UNDERGROUND / UNDERFLOOR
PROVIDED TO INDICATE 'A' AND 'B' SIDE SOURCED POWER FEEDERS.
REFERENCE GENERAL SYMBOL LEGEND FOR ADDITIONAL
INFORMATION.
LEGEND
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/0
/2
:4
:4 a m
B
IM
/5
-2
-7
V A
H u n t i n g to n E
H R
M /E
E
B L D
G
B A
S E
M E
N T
.r v t
01SEP400Bc
BLDG 01S - LEVEL 00B - ENLARGED
ELECTRICAL PLANS
01S
DCW/NVP RTS/JNV
100% CONSTRUCTION
DOCUMENTS
09/03/2025
581-22-700EHRM INFRASTRUCTURE
UPGRADES - HUNTINGTON
VA HUNTINGTON
1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300
KEY PLAN
GENERAL NOTES
PROJECT
NORTH
HOUSEKEEPING PAD, 3-1/2" WITH CHAMFERED EDGE, SIZE PER EQUIPMENT FOOT
PRINT. PROVIDE 5000PSI CONCRETE WITH #4 REBAR, 12" OC, REBAR SHALL BE TIED,
COORDINATE REBAR INSTALLATION WITH CONDUIT INSTALLATIONS AS REQUIRED.
PROVIDE UNISTRUT RACK TO SUPPORT CONDUIT AS REQUIRED.
TRANSFORMER SHALL BE PLACED FACING PLAN NORTH TOWARDS DOOR WAY.
KEY NOTES
1/2" = 1'-0"01SEP100B
1 RM BB110D - DEMOLITION ELECTRICAL PLAN
1/2" = 1'-0"01SEP100B
2 RM BB110D - ELECTRICAL PLAN1'0 2' 4'
PROJECT
NORTH
1'0 2' 4'
PROJECT
NORTH
Revisions: Date:
1. DEMOLITION PLANS/NOTES ARE BASED ON SITE INVESTIGATIONS AND RECORD
DRAWINGS. IF DISCREPANCIES ARE FOUND THAT MAY IMPACT WORK, PROMPTLY
NOTIFY VA AND ENGINEER OF SAID DISCREPANCY.
2. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR CLARITY. CONTRACTOR SHALL
FIELD VERIFY ALL POWER, LIGHTING AND ASSOCIATED CIRCUITRY AS REQUIRED.
ALL RACEWAYS AND CONDUCTORS ASSOCIATED WITH EQUIPMENT TO BE
DEMOLISHED SHALL BE DEMOLISHED BACK TO THEIR SOURCE, UNLESS
OTHERWISE NOTED.
3. CONTRACTOR SHALL DEMOLISH ALL ELECTRICAL EQUIPMENT, CONDUCTORS AND
RACEWAYS ASSOCIATED WITH WALLS BEING REMOVED, AND IN ALL LOCATIONS
WHERE JUNCTION BOXES WILL NOT REMAIN ACCESSIBLE AFTER INSTALLATION,
UNLESS OTHERWISE NOTED.
4. CONTRACTOR SHALL COORDINATE NORMAL/ESSENTIAL ELECTRICAL SYSTEM
SHUTDOWNS AND PHASING WITH THE VA PRIOR TO PERFORMING REQUIRED
EQUIPMENT UPGRADES. CONTRACTOR TO PROVIDE BACKUP EMERGENCY POWER
AND DETERMINE TIE-IN/CONNECTION PLAN WITH EXISTING EQUIPMENT. POWER TO
ALL EXISTING ESSENTIAL EQUIPMENT CANNOT BE INTERRUPTED AND SHALL
REMAIN ACTIVE DURING CONSTRUCTION. BACKUP POWER AND TIE-IN SHALL
CONFORM WITH VA STANDARDS.
5. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO MATCH EXISTING FIRE
RATING OR NEW FIRE RATING; PROVIDE CORE DRILLING AS REQUIRED.
COORDINATE WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS AS REQUIRED.
6. REFERENCE CORRESPONDING ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION.
7. CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT PANEL DIRECTORIES FOR ALL
PANELS THAT CONTAIN CIRCUITS IMPACTED BY THIS PROJECT.
8. CONTRACTOR SHALL PROVIDE PULL BOXES FOR ALL FEEDERS WHERE FEEDER
RUNS EXCEED 250FT OR HAVE MORE THAN 270 DEGREES OF TOTAL BEND. PULL
BOX PLACEMENTS AND SIZING BY CONTRACTOR. COORDINATE PULL BOX
LOCATIONS WITH ALL OBSTRUCTIONS, TRADES, AND VA AS REQUIRED.
9. ALL RECEPTACLES AND SWITCHES SHALL BE PROVIDED WITH PANEL AND CIRCUIT
LABELING LOCATED DIRECTLY ON THE WALL PLATE; IE:"P4-1", PANEL "4", CIRCUIT
"1". REFERENCE WIRING DEVICE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
A
A
A
BBB
EP502
BBBBBBB
AAAAAAA
B
B
B
B
B
AA
AAA
BBBBBBB
A A A
A
A
A
A
A
A
A
A
A
AAAAAAA
BBBBBBB
BBBBBBB
BBBBBBB
Mo
A A
B B
A A
B B
AREA SHOWN
X
TYP.
X
01S-T1-00GB
01S-T1-00GA 2
01S-FCU-01-T1-00G7
01S-T1-00GA-27
ACCESS CONTROL
PANEL "01S-ACP-T100G"
01S-T1-00GA-27
TR TOWER 1
T1-00G
169 SF
P-TR-2A
01S-BDCB-TWR1B
01S-BDCB-TWR1A
BUSDUCT
"01S-BD-TWR1B"
BUSDUCT
"01S-BD-TWR1A"
01S-PA-12
01S-PA-10
01S-T1-00GA-10,12
D
D
01S-PA-1111
BUS DUCT CIRCUIT BREAKER
"01S-BDCB-BB100B-1SA" (ABOVE)
BUS DUCT CIRCUIT BREAKER
"01S-BDCB-01S-T1-00GA" (BELOW)
01S-PB-11A10
01S-PB-12
BUS DUCT CIRCUIT BREAKER
"01S-BDCB-BB100B-1SB" (ABOVE)
BUS DUCT CIRCUIT BREAKER
"01S-BDCB-01S-T1-00GB" (BELOW)
CABLE TAP BOX
"01S-CTB-TWR1B"
(BELOW)
EP506
01S-PB-11B
CABLE TAP BOX
"01S-CTB-TWR1A"
(BELOW)
01S-PA-11B
P-TR-2B
01S-PB-13
FROM SHEET 01AEP100G
TO SHEET 01EG400Gb-1B
EP506
EP504
EP506
EP506
X
L1
L1
L1
L1
01S-T1-00GB
01S-T1-00GA
DATA RACK,
TYP.
01S-T1-00GA-4
TR TOWER 1
T1-00G
169 SF
TYP.
EP508
EP508
T1-00G
ENCLOSED
COURTYARD
1585 SF
X
ENCLOSED
COURTYARD
1585 SF
A SIDE POWER, CONCEALED WHERE POSSIBLE
B SIDE POWER, CONCEALED WHERE POSSIBLE
A SIDE POWER, UNDERGROUND / UNDERFLOOR
B SIDE POWER, UNDERGROUND / UNDERFLOOR
PROVIDED TO INDICATE 'A' AND 'B' SIDE SOURCED POWER FEEDERS.
REFERENCE GENERAL SYMBOL LEGEND FOR ADDITIONAL
INFORMATION.
LEGEND
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/0
/2
:4
:1 a m
B
IM
/5
-2
-7
V A
H u n t i n g to n E
H R
M /E
E
B L D
G
G R
O U
N D
F L
O O
R .r v t
01SEP400Ga
BLDG 01S - LEVEL 00G - ENLARGED
ELECTRICAL PLANS
01S
DCW/NVP RTS/JNV
100% CONSTRUCTION
DOCUMENTS
09/03/2025
581-22-700EHRM INFRASTRUCTURE
UPGRADES - HUNTINGTON
VA HUNTINGTON
1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300
PROJECT
NORTH
EXISTING EQUIPMENT SHALL BE DEMOLISHED. ASSOCIATED CONDUIT AND WIRE
SHALL BE DEMOLISHED BACK TO SOURCE.
SOURCE A POWER PANELBOARD "01S-T1-00GA".
SOURCE B POWER PANELBOARD "01S-T1-00GB".
PROVIDE SECONDARY BONDING BUSBAR. REFERENCE TELECOMMUNICATIONS
BONDING RISER DIAGRAM(S) FOR ADDITIONAL INFORMATION.
OVERHEAD TR RACK SOURCE A AND SOURCE B POWER RECEPTACLE.
FURNISH AND INSTALL BOXED POWER SUPPLIES AS INDICATED ABOVE ACCESSIBLE
CEILINGS. VERIFY LOCATIONS WITH ARCHITECT. PROVIDE (1) POWER SUPPLY FOR
EACH DOOR OPENING. PROVIDE 120V POWER TO ADEQUATE SERVE DOORS WITH
ELECTRIFIED DOOR HARDWARE AND MAKE CONNECTIONS AS REQUIRED. SEE
EQUIREMENTS IN 08 71 00 - DOOR HARDWARE. COORDINATE WITH ARCHITECT AND
DOOR INSTALLER.
PROVIDE RACEWAYS AND CONDUCTORS PER MANUFACTURER'S REQUIREMENT.
COORDINATE WITH MECHANICAL CONTRACTOR AS REQUIRED.
(2) VERTICALLY STACKED DISCONNECTS. TOP DISCONNECT FEEDS PANELBOARD
"01S-T1-00GA"; BOTTOM DISCONNECT FEEDS PANELBOARD "01S-BB100B-1SA".
REFERENCE SHEET 01SEP100B FOR ADDITIONAL INFORMATION.
(2) VERTICALLY STACKED DISCONNECTS. TOP DISCONNECT FEEDS PANELBOARD
"01S-T1-00GB"; BOTTOM DISCONNECT FEEDS PANELBOARD "01S-BB100B-1SB".
REFERENCE SHEET 01SEP100B FOR ADDITIONAL INFORMATION.
CONDUIT ROUTED VERTICALLY FROM CRAWL SPACE LOCATED ON THE BELOW
FLOOR. REFERENCE SHEET 01SEP100B FOR ADDITIONAL INFORMATION.
CONDUIT ROUTED VERTICALLY TO CRAWL SPACE LOCATED ON THE BELOW FLOOR.
REFERENCE SHEET 01SEP100B FOR ADDITIONAL INFORMATION.
PROVIDE TBB AS INDICATED; WHERE CONDUCTOR IS SUBJECT TO PHYSICAL
DAMAGE, CONDUCTOR SHALL BE ROUTED THROUGH RMC. REFERENCE
TELECOMMUNICATIONS BONDING RISER DIAGRAM ON SHEET EG601 FOR ADDITIONAL
INFORMATION.
PROVIDE SBC AS INDICATED; WHERE CONDUCTOR IS SUBJECT TO PHYSICAL
DAMAGE, CONDUCTOR SHALL BE ROUTED THROUGH RMC. REFERENCE
TELECOMMUNICATIONS BONDING RISER DIAGRAM ON SHEET EG601 FOR ADDITIONAL
INFORMATION.
1/2" = 1'-0"01SEP100G
1 RM T1-00G - DEMOLITION ELECTRICAL PLAN
1/2" = 1'-0"01SEP100G
2 RM T1-00G - ELECTRICAL PLAN
1/2" = 1'-0"01SEP100G
4 RM T1-00G - LIGHTING AND RECEPTACLE PLAN
1'0 2' 4'
PROJECT
NORTH
1'0 2' 4'
PROJECT
NORTH
1'0 2' 4'
PROJECT
NORTH
GENERAL NOTES
KEY PLAN
KEY NOTES
1. DEMOLITION PLANS/NOTES ARE BASED ON SITE INVESTIGATIONS AND RECORD
DRAWINGS. IF DISCREPANCIES ARE FOUND THAT MAY IMPACT WORK, PROMPTLY
NOTIFY VA AND ENGINEER OF SAID DISCREPANCY.
2. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR CLARITY. CONTRACTOR SHALL
FIELD VERIFY ALL POWER, LIGHTING AND ASSOCIATED CIRCUITRY AS REQUIRED. ALL
RACEWAYS AND CONDUCTORS ASSOCIATED WITH EQUIPMENT TO BE DEMOLISHED
SHALL BE DEMOLISHED BACK TO THEIR SOURCE, UNLESS OTHERWISE NOTED.
3. CONTRACTOR SHALL DEMOLISH ALL ELECTRICAL EQUIPMENT, CONDUCTORS AND
RACEWAYS ASSOCIATED WITH WALLS BEING REMOVED, AND IN ALL LOCATIONS
WHERE JUNCTION BOXES WILL NOT REMAIN ACCESSIBLE AFTER INSTALLATION,
UNLESS OTHERWISE NOTED.
4. CONTRACTOR SHALL COORDINATE NORMAL/ESSENTIAL ELECTRICAL SYSTEM
SHUTDOWNS AND PHASING WITH THE VA PRIOR TO PERFORMING REQUIRED
EQUIPMENT UPGRADES. CONTRACTOR TO PROVIDE BACKUP EMERGENCY POWER
AND DETERMINE TIE-IN/CONNECTION PLAN WITH EXISTING EQUIPMENT. POWER TO
ALL EXISTING ESSENTIAL EQUIPMENT CANNOT BE INTERRUPTED AND SHALL REMAIN
ACTIVE DURING CONSTRUCTION. BACKUP POWER AND TIE-IN SHALL CONFORM WITH
VA STANDARDS.
5. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO MATCH EXISTING FIRE
RATING OR NEW FIRE RATING; PROVIDE CORE DRILLING AS REQUIRED. COORDINATE
WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS AS REQUIRED.
6. REFERENCE CORRESPONDING ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION.
7. CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT PANEL DIRECTORIES FOR ALL
PANELS THAT CONTAIN CIRCUITS IMPACTED BY THIS PROJECT.
8. CONTRACTOR SHALL PROVIDE PULL BOXES FOR ALL FEEDERS WHERE FEEDER RUNS
EXCEED 250FT OR HAVE MORE THAN 270 DEGREES OF TOTAL BEND. PULL BOX
PLACEMENT AND SIZING BY CONTRACTOR. COORDINATE PULL BOX LOCATIONS WITH
ALL OBSTRUCTIONS, TRADES, AND VA AS REQUIRED.
9. ALL RECEPTACLES AND SWITCHES SHALL BE PROVIDED WITH PANEL AND CIRCUIT
LABELING LOCATED DIRECTLY ON THE WALL PLATE; IE:"P4-1", PANEL "4", CIRCUIT "1".
REFERENCE WIRING DEVICE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
1/2" = 1'-0"01SEP100G
3 RM T1-00G - DEMOLITION LIGHTING PLAN 1'0 2' 4'
PROJECT
NORTH
Revisions: Date:
BUSDUCT
L1
AAAAAAAA
EP502
BB
BB
BB
AAAAAAA
A
A
A
B B B B
B
B
Mo
A A
B B
A A
B B
AREA SHOWN
P
EP504
TR TOWER 4
T4-00G
166 SF
01S-T4-00GA
01S-T4-00GB
601S-FCU-02-T4-00G
ACCESS CONTROL
PANEL "01S-ACP-T400G"
01S-T4-00GA-25
01S-T4-00GA-25
P-TR-1A
BUS DUCT
"01S-BD-TWR4A"
EP506
BUS DUCT
"01S-BD-TWR4B"
01S-BDCB-TWR4B
01S-BDCB-TWR4A
EP506
01S-PA-03 01S-T4-00GA-10,12
01S-PA-02B 7
BUS DUCT CIRCUIT BREAKER
"01S-BDCB-T4-00GA"
BUS DUCT CIRCUIT BREAKER
"01S-BDCB-T4-00GA"
01S-PB-03B 7
D D
01S-PA-02C
EP506
1 CABLE TAP BOX
"01S-CTB-TWR4B"
(BELOW)
CABLE TAP BOX
"01S-CTB-TWR4B"
(BELOW)
EP506
01S-PA-03C
P-TR-1B
01S-PB-04
P
01S-T4-00GA
01S-T4-00GB
TR TOWER 4
T4-00G
166 SF
L4L4
L4 L4
01S-T4-00GA-4
TYP.
EP508
2TYP.
EP508
6 2
T4-00G
A SIDE POWER, CONCEALED WHERE POSSIBLE
B SIDE POWER, CONCEALED WHERE POSSIBLE
A SIDE POWER, UNDERGROUND / UNDERFLOOR
B SIDE POWER, UNDERGROUND / UNDERFLOOR
PROVIDED TO INDICATE 'A' AND 'B' SIDE SOURCED POWER FEEDERS.
REFERENCE GENERAL SYMBOL LEGEND FOR ADDITIONAL
INFORMATION.
LEGEND
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/0
/2
:4
:2 a m
B
IM
/5
-2
-7
V A
H u n t i n g to n E
H R
M /E
E
B L D
G
G R
O U
N D
F L
O O
R .r v t
01SEP400Gb
BLDG 01S - LEVEL 00G - ENLARGED
ELECTRICAL PLANS
01S
DCW/NVP RTS/JNV
100% CONSTRUCTION
DOCUMENTS
09/03/2025
581-22-700EHRM INFRASTRUCTURE
UPGRADES - HUNTINGTON
VA HUNTINGTON
1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300
PROJECT
NORTH
SOURCE A POWER PANELBOARD "01S-T4-00GA".
SOURCE B POWER PANELBOARD "01S-T4-00GB".
PROVIDE SECONDARY BONDING BUSBAR. REFERENCE TELECOMMUNICATIONS
BONDING RISER DIAGRAM(S) FOR ADDITIONAL INFORMATION.
OVERHEAD TR RACK SOURCE A AND SOURCE B POWER RECEPTACLE.
FURNISH AND INSTALL BOXED POWER SUPPLIES AS INDICATED ABOVE
ACCESSIBLE CEILINGS. VERIFY LOCATIONS WITH ARCHITECT. PROVIDE (1) POWER
SUPPLY FOR EACH DOOR OPENING. PROVIDE 120V POWER TO ADEQUATE SERVE
DOORS WITH ELECTRIFIED DOOR HARDWARE AND MAKE CONNECTIONS AS
REQUIRED. SEE EQUIREMENTS IN 08 71 00 - DOOR HARDWARE. COORDINATE WITH
ARCHITECT AND DOOR INSTALLER.
PROVIDE RACEWAYS AND CONDUCTORS PER MANUFACTURER'S REQUIREMENT.
COORDINATE WITH MECHANICAL CONTRACTOR AS REQUIRED.
CONDUIT ROUTED VERTICALLY FROM CORRIDOR LOCATED ON THE BELOW FLOOR.
REFERENCE SHEET 01SEP100B FOR ADDITIONAL INFORMATION.
PROVIDE TBB AS INDICATED; WHERE CONDUCTOR IS SUBJECT TO PHYSICAL
DAMAGE, CONDUCTOR SHALL BE ROUTED THROUGH RMC. REFERENCE
TELECOMMUNICATIONS BONDING RISER DIAGRAM ON SHEET EG601 FOR ADDITIONAL
INFORMATION.
PROVIDE SBC AS INDICATED; WHERE CONDUCTOR IS SUBJECT TO PHYSICAL
DAMAGE, CONDUCTOR SHALL BE ROUTED THROUGH RMC. REFERENCE
TELECOMMUNICATIONS BONDING RISER DIAGRAM ON SHEET EG601 FOR ADDITIONAL
INFORMATION.
1/2" = 1'-0"01SEP100G
2 RM T4-00G - ELECTRICAL PLAN
1/2" = 1'-0"01SEP100G
4 RM T4-00G - LIGHTING AND RECEPTACLE PLAN
1'0 2' 4'
PROJECT
NORTH
1'0 2' 4'
PROJECT
NORTH
GENERAL NOTES
KEY PLAN
KEY NOTES
1. DEMOLITION PLANS/NOTES ARE BASED ON SITE INVESTIGATIONS AND RECORD
DRAWINGS. IF DISCREPANCIES ARE FOUND THAT MAY IMPACT WORK, PROMPTLY
NOTIFY VA AND ENGINEER OF SAID DISCREPANCY.
2. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR CLARITY. CONTRACTOR SHALL
FIELD VERIFY ALL POWER, LIGHTING AND ASSOCIATED CIRCUITRY AS REQUIRED. ALL
RACEWAYS AND CONDUCTORS ASSOCIATED WITH EQUIPMENT TO BE DEMOLISHED
SHALL BE DEMOLISHED BACK TO THEIR SOURCE, UNLESS OTHERWISE NOTED.
3. CONTRACTOR SHALL DEMOLISH ALL ELECTRICAL EQUIPMENT, CONDUCTORS AND
RACEWAYS ASSOCIATED WITH WALLS BEING REMOVED, AND IN ALL LOCATIONS
WHERE JUNCTION BOXES WILL NOT REMAIN ACCESSIBLE AFTER INSTALLATION,
UNLESS OTHERWISE NOTED.
4. CONTRACTOR SHALL COORDINATE NORMAL/ESSENTIAL ELECTRICAL SYSTEM
SHUTDOWNS AND PHASING WITH THE VA PRIOR TO PERFORMING REQUIRED
EQUIPMENT UPGRADES. CONTRACTOR TO PROVIDE BACKUP EMERGENCY POWER
AND DETERMINE TIE-IN/CONNECTION PLAN WITH EXISTING EQUIPMENT. POWER TO
ALL EXISTING ESSENTIAL EQUIPMENT CANNOT BE INTERRUPTED AND SHALL REMAIN
ACTIVE DURING CONSTRUCTION. BACKUP POWER AND TIE-IN SHALL CONFORM WITH
VA STANDARDS.
5. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO MATCH EXISTING FIRE
RATING OR NEW FIRE RATING; PROVIDE CORE DRILLING AS REQUIRED. COORDINATE
WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS AS REQUIRED.
6. REFERENCE CORRESPONDING ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION.
7. CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT PANEL DIRECTORIES FOR ALL
PANELS THAT CONTAIN CIRCUITS IMPACTED BY THIS PROJECT.
8. CONTRACTOR SHALL PROVIDE PULL BOXES FOR ALL FEEDERS WHERE FEEDER RUNS
EXCEED 250FT OR HAVE MORE THAN 270 DEGREES OF TOTAL BEND. PULL BOX
PLACEMENT AND SIZING BY CONTRACTOR. COORDINATE PULL BOX LOCATIONS WITH
ALL OBSTRUCTIONS, TRADES, AND VA AS REQUIRED.
9. ALL RECEPTACLES AND SWITCHES SHALL BE PROVIDED WITH PANEL AND CIRCUIT
LABELING LOCATED DIRECTLY ON THE WALL PLATE; IE:"P4-1", PANEL "4", CIRCUIT "1".
REFERENCE WIRING DEVICE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
Revisions: Date:
BUS DUCT
Mo
EP502
B
B
B
B
B
B B
BB
A
A
A
A
A
A
BBBBBBB
A
A
A
AA
AAAAAA
AAAAAAA
A
A
A
A
A
A
A
A
A
AAA
J
J J
EP502
A
A
AAAAAAA
B B B
BB
B
B
B
B
BBBBBBB
BBBBBBBB
AAAAAAAAA
Mo
A A
B B
A A
B B
AREA SHOWN
X
01S-T1-01A
01S-T1-01B
L1
L1
L1 L1
TR TOWER 1
T1-01
166 SF
01S-T1-01A-4
EP508
TYP.
EP508
2 2
X
01S-T1-01A
01S-T1-01B 2
EP504
TR TOWER 1
T1-01
166 SF
01S-FCU-03-T1-017
ACCESS
CONTROL
PANEL
"01S-ACP-T101"
01S-T1-01A-27
P-TR-2A
P-TR-2B
01S-T1-01A-27
BUS DUCT
"01S-BD-TWR1B"
EP506
01S-PA-13
01S-PB-14
BUS DUCT
"01S-BD-TWR1A"
EP506
01S-T1-01A-10,12
BUS DUCT CIRCUIT BREAKER
"01S-BDCB-T1-01A"
BUS DUCT CIRCUIT BREAKER
"01S-BDCB-T1-01B"
D
D
TO SHEET 01SEP101
01S-PA-21
T1-01
T4-01
P
EP504
01S-T4-01B
01S-T4-01A
TR TOWER 4
T4-01
160 SF
701S-FCU-04-T4-01
ACCESS
CONTROL
PANEL
"01S-ACP-T401"
01S-T4-01A-25
01S-T4-01A-25
01S-PB-05
01S-PA-04
EP506
BUS DUCT
"01S-BD-TWR4A"
EP506
P-TR-3A
P-TR-3B
01S-T4-01A-10,12
BUS DUCT CIRCUIT BREAKER
"01S-BDCB-T4-01A"
BUS DUCT CIRCUIT BREAKER
"01S-BDCB-T4-01B"
BUS DUCT
"01S-BD-TWR4B"
P
L4
L4L4
L4
TR TOWER 4
T4-01
160 SF
01S-T4-01B
01S-T4-01A
01S-T4-01A-4
TYP.
EP508
EP508
A SIDE POWER, CONCEALED WHERE POSSIBLE
B SIDE POWER, CONCEALED WHERE POSSIBLE
A SIDE POWER, UNDERGROUND / UNDERFLOOR
B SIDE POWER, UNDERGROUND / UNDERFLOOR
PROVIDED TO INDICATE 'A' AND 'B' SIDE SOURCED POWER FEEDERS.
REFERENCE GENERAL SYMBOL LEGEND FOR ADDITIONAL
INFORMATION.
LEGEND
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/3
/2
:2
:5
A
M
B
IM
/5
-2
-7
V A
H u n t i n g to n E
H R
M /E
E
B L D
G
L E
V E
L
.r v t
01SEP401
BLDG 01S - LEVEL 01 - ENLARGED ELECTRICAL
PLANS
01S
DCW/NVP RTS/JNV
100% CONSTRUCTION
DOCUMENTS
09/03/2025
581-22-700EHRM INFRASTRUCTURE
UPGRADES - HUNTINGTON
VA HUNTINGTON
1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300
GENERAL NOTES
KEY PLAN
PROJECT
NORTH
1/2" = 1'-0"01SEP101
3 RM T1-01 - LIGHTING AND RECEPTACLE PLAN
1/2" = 1'-0"01SEP101
1 RM T1-01 - ELECTRICAL PLAN
1'0 2' 4'
PROJECT
NORTH
KEY NOTES
1'0 2' 4'
PROJECT
NORTH
Revisions: Date:
1/2" = 1'-0"01SEP101
2 RM T4-01 - ELECTRICAL PLAN
1/2" = 1'-0"01SEP101
4 RM T4-01 - LIGHTING AND RECEPTACLE PLAN
1'0 2' 4'
PROJECT
NORTH
1'0 2' 4'
PROJECT
NORTH
SOURCE A POWER PANELBOARD "01S-T1-01A".
SOURCE B POWER PANELBOARD "01S-T1-01B".
SECONDARY BONDING BUSBAR.
OVERHEAD TR RACK SOURCE A AND SOURCE B POWER JUNCTION BOX.
OVERHEAD TR RACK SOURCE A AND SOURCE B POWER POWER RECEPTACLE.
FURNISH AND INSTALL BOXED POWER SUPPLIES AS INDICATED ABOVE ACCESSIBLE
CEILINGS. VERIFY LOCATIONS WITH ARCHITECT. PROVIDE (1) POWER SUPPLY FOR
EACH DOOR OPENING. PROVIDE 120V POWER TO ADEQUATELY SERVE DOORS WITH
ELECTRIFIED DOOR HARDWARE AND MAKE CONNECTIONS AS REQUIRED. SEE
REQUIREMENTS IN 08 71 00 - DOOR HARDWARE. COORDINATE WITH ARCHITECT AND
DOOR INSTALLER.
PROVIDE RACEWAYS AND CONDUCTORS PER MANUFACTURER'S REQUIREMENT.
COORDINATE WITH MECHANICAL CONTRACTOR AS REQUIRED.
SOURCE A POWER PANELBOARD "01S-T4-01A".
SOURCE B POWER PANELBOARD "01S-T4-01B".
PROVIDE TBB AS INDICATED; WHERE CONDUCTOR IS SUBJECT TO PHYSICAL
DAMAGE, CONDUCTOR SHALL BE ROUTED THROUGH RMC. REFERENCE
TELECOMMUNICATIONS BONDING RISER DIAGRAM ON SHEET EG601 FOR ADDITIONAL
INFORMATION.
PROVIDE SBC AS INDICATED; WHERE CONDUCTOR IS SUBJECT TO PHYSICAL
DAMAGE, CONDUCTOR SHALL BE ROUTED THROUGH RMC. REFERENCE
TELECOMMUNICATIONS BONDING RISER DIAGRAM ON SHEET EG601 FOR ADDITIONAL
INFORMATION.
1. DEMOLITION PLANS/NOTES ARE BASED ON SITE INVESTIGATIONS AND RECORD
DRAWINGS. IF DISCREPANCIES ARE FOUND THAT MAY IMPACT WORK, PROMPTLY
NOTIFY VA AND ENGINEER OF SAID DISCREPANCY.
2. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR CLARITY. CONTRACTOR SHALL
FIELD VERIFY ALL POWER, LIGHTING AND ASSOCIATED CIRCUITRY AS REQUIRED.
ALL RACEWAYS AND CONDUCTORS ASSOCIATED WITH EQUIPMENT TO BE
DEMOLISHED SHALL BE DEMOLISHED BACK TO THEIR SOURCE, UNLESS
OTHERWISE NOTED.
3. CONTRACTOR SHALL DEMOLISH ALL ELECTRICAL EQUIPMENT, CONDUCTORS AND
RACEWAYS ASSOCIATED WITH WALLS BEING REMOVED, AND IN ALL LOCATIONS
WHERE JUNCTION BOXES WILL NOT REMAIN ACCESSIBLE AFTER INSTALLATION,
UNLESS OTHERWISE NOTED.
4. CONTRACTOR SHALL COORDINATE NORMAL/ESSENTIAL ELECTRICAL SYSTEM
SHUTDOWNS AND PHASING WITH THE VA PRIOR TO PERFORMING REQUIRED
EQUIPMENT UPGRADES. CONTRACTOR TO PROVIDE BACKUP EMERGENCY POWER
AND DETERMINE TIE-IN/CONNECTION PLAN WITH EXISTING EQUIPMENT. POWER TO
ALL EXISTING ESSENTIAL EQUIPMENT CANNOT BE INTERRUPTED AND SHALL
REMAIN ACTIVE DURING CONSTRUCTION. BACKUP POWER AND TIE-IN SHALL
CONFORM WITH VA STANDARDS.
5. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO MATCH EXISTING FIRE
RATING OR NEW FIRE RATING; PROVIDE CORE DRILLING AS REQUIRED.
COORDINATE WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS AS REQUIRED.
6. REFERENCE CORRESPONDING ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION.
7. CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT PANEL DIRECTORIES FOR ALL
PANELS THAT CONTAIN CIRCUITS IMPACTED BY THIS PROJECT.
8. CONTRACTOR SHALL PROVIDE PULL BOXES FOR ALL FEEDERS WHERE FEEDER
RUNS EXCEED 250FT OR HAVE MORE THAN 270 DEGREES OF TOTAL BEND. PULL
BOX PLACEMENTS AND SIZING BY CONTRACTOR. COORDINATE PULL BOX
LOCATIONS WITH ALL OBSTRUCTIONS, TRADES, AND VA AS REQUIRED.
9. ALL RECEPTACLES AND SWITCHES SHALL BE PROVIDED WITH PANEL AND CIRCUIT
LABELING LOCATED DIRECTLY ON THE WALL PLATE; IE:"P4-1", PANEL "4", CIRCUIT
"1". REFERENCE WIRING DEVICE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
A
A
A
EP502
B
B
B
B
B
BBB
BBBBBB
A A A
AAAAAAA
BBBBBBB
Mo
A A
B B
A A
B B
J
JJ
B B
EP502
AAAAAAA
A
A
AAAAA
BB
B B B
BB
B
B
B
B
Mo
AREA SHOWN
X
01S-T1-02A
01S-T1-02B 2
01S-FCU-05-T1-026
TR TOWER 1
T1-02
166 SF
ACCESS CONTROL
PANEL "01S-ACP-T1-02"
EP504
01S-T1-02A-23
01S-T1-02A-23
P-TR-2A
P-TR-2B
EP506
EP506
01S-PB-15
01S-T1-02A-10,12
01S-PA-14
BUS DUCT CIRCUIT BREAKER
"01S-BDCB-T1-02B"
BUS DUCT CIRCUIT BREAKER
"01S-BDCB-T1-02A"
D
D
BUS DUCT
"01S-BD-TWR1A"
BUS DUCT
"01S-BD-TWR1B"
X
01S-T1-02A
01S-T1-02B
TR TOWER 1
T1-02
166 SF
L1
L1
L1 L1
01S-T1-02A-4
TYP.
EP508
EP508
T1-02T4-02
A SIDE POWER, CONCEALED WHERE POSSIBLE
B SIDE POWER, CONCEALED WHERE POSSIBLE
A SIDE POWER, UNDERGROUND / UNDERFLOOR
B SIDE POWER, UNDERGROUND / UNDERFLOOR
PROVIDED TO INDICATE 'A' AND 'B' SIDE SOURCED POWER FEEDERS.
REFERENCE GENERAL SYMBOL LEGEND FOR ADDITIONAL
INFORMATION.
LEGEND
P
01S-T4-02A
01S-T4-02B
TR TOWER 4
T4-02
160 SF
01S-FCU-06-T4-026
ACCESS CONTROL
PANEL "01S-ACP-T4-02"
EP504
01S-T4-02A-25
01S-T4-02A-25
P-TR-3A
P-TR-3B
01S-PA-05
BUS DUCT
"01S-BD-TWR4B"
BUS DUCT
"01S-BD-TWR4A"
EP506
EP506
01S-PB-06
01S-T4-02A-10
BUS DUCT CIRCUIT BREAKER
"01S-BDCB-T4-02A"
BUS DUCT CIRCUIT BREAKER
"01S-BDCB-T4-02B"
P
01S-T4-02B
TR TOWER 4
T4-02
160 SF
L4 L4
L4 L4
01S-T4-02A
01S-T4-02A-4
EP508
TYP.
EP508
2 6
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/0
/2
:2
:1 a m
B
IM
/5
-2
-7
V A
H u n t i n g to n E
H R
M /E
E
B L D
G
L E
V E
L
.r v t
01SEP402
BLDG 01S - LEVEL 02 - ENLARGED ELECTRICAL
PLANS
01S
DCW/NVP RTS/JNV
100% CONSTRUCTION
DOCUMENTS
09/03/2025
581-22-700EHRM INFRASTRUCTURE
UPGRADES - HUNTINGTON
VA HUNTINGTON
1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300
GENERAL NOTES
KEY PLAN
SOURCE A POWER PANELBOARD "01S-T1-02A".
SOURCE B POWER PANELBOARD "01S-T1-02B".
PROVIDE SECONDARY BONDING BUSBAR. REFERENCE TELECOMMUNICATIONS
BONDING RISER DIAGRAM(S) FOR ADDITIONAL INFORMATION.
OVERHEAD TR RACK SOURCE A AND SOURCE B POWER RECEPTACLE.
FURNISH AND INSTALL BOXED POWER SUPPLIES AS INDICATED ABOVE
ACCESSIBLE CEILINGS. VERIFY LOCATIONS WITH ARCHITECT. PROVIDE (1) POWER
SUPPLY FOR EACH DOOR OPENING. PROVIDE 120V POWER TO ADEQUATE SERVE
DOORS WITH ELECTRIFIED DOOR HARDWARE AND MAKE CONNECTIONS AS
REQUIRED. SEE EQUIREMENTS IN 08 71 00 - DOOR HARDWARE. COORDINATE WITH
ARCHITECT AND DOOR INSTALLER.
PROVIDE RACEWAYS AND CONDUCTORS PER MANUFACTURER'S REQUIREMENT.
COORDINATE WITH MECHANICAL CONTRACTOR AS REQUIRED.
SOURCE A POWER PANELBOARD "01S-T4-02A".
SOURCE B POWER PANELBOARD "01S-T4-02B".
PROVIDE TBB AS INDICATED; WHERE CONDUCTOR IS SUBJECT TO PHYSICAL
DAMAGE, CONDUCTOR SHALL BE ROUTED THROUGH RMC. REFERENCE
TELECOMMUNICATIONS BONDING RISER DIAGRAM ON SHEET EG601 FOR ADDITIONAL
INFORMATION.
PROVIDE SBC AS INDICATED; WHERE CONDUCTOR IS SUBJECT TO PHYSICAL
DAMAGE, CONDUCTOR SHALL BE ROUTED THROUGH RMC. REFERENCE
TELECOMMUNICATIONS BONDING RISER DIAGRAM ON SHEET EG601 FOR ADDITIONAL
INFORMATION.
- 1/2" = 1'-0"
1 RM T1-02 - ELECTRICAL PLAN
- 1/2" = 1'-0"
2 RM T1-02- LIGHTING AND RECEPTACLE PLAN
1'0 2' 4'
PROJECT
NORTH
PROJECT
NORTH
1'0 2' 4'
PROJECT
NORTH
KEY NOTES
1. DEMOLITION PLANS/NOTES ARE BASED ON SITE INVESTIGATIONS AND RECORD
DRAWINGS. IF DISCREPANCIES ARE FOUND THAT MAY IMPACT WORK, PROMPTLY
NOTIFY VA AND ENGINEER OF SAID DISCREPANCY.
2. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR CLARITY. CONTRACTOR SHALL
FIELD VERIFY ALL POWER, LIGHTING AND ASSOCIATED CIRCUITRY AS REQUIRED.
ALL RACEWAYS AND CONDUCTORS ASSOCIATED WITH EQUIPMENT TO BE
DEMOLISHED SHALL BE DEMOLISHED BACK TO THEIR SOURCE, UNLESS
OTHERWISE NOTED.
3. CONTRACTOR SHALL DEMOLISH ALL ELECTRICAL EQUIPMENT, CONDUCTORS AND
RACEWAYS ASSOCIATED WITH WALLS BEING REMOVED, AND IN ALL LOCATIONS
WHERE JUNCTION BOXES WILL NOT REMAIN ACCESSIBLE AFTER INSTALLATION,
UNLESS OTHERWISE NOTED.
4. CONTRACTOR SHALL COORDINATE NORMAL/ESSENTIAL ELECTRICAL SYSTEM
SHUTDOWNS AND PHASING WITH THE VA PRIOR TO PERFORMING REQUIRED
EQUIPMENT UPGRADES. CONTRACTOR TO PROVIDE BACKUP EMERGENCY POWER
AND DETERMINE TIE-IN/CONNECTION PLAN WITH EXISTING EQUIPMENT. POWER TO
ALL EXISTING ESSENTIAL EQUIPMENT CANNOT BE INTERRUPTED AND SHALL
REMAIN ACTIVE DURING CONSTRUCTION. BACKUP POWER AND TIE-IN SHALL
CONFORM WITH VA STANDARDS.
5. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO MATCH EXISTING FIRE
RATING OR NEW FIRE RATING; PROVIDE CORE DRILLING IF REQUIRED.
COORDINATE WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS AS REQUIRED.
6. REFERENCE CORRESPONDING ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION.
7. CONTRACTOR SHALL PROVIDE UPDATED CIRCUIT PANEL DIRECTORIES FOR ALL
PANELS THAT CONTAIN CIRCUITS IMPACTED BY THIS PROJECT.
8. CONTRACTOR SHALL PROVIDE PULL BOXES FOR ALL FEEDERS WHERE FEEDER
RUNS EXCEED 250FT OR HAVE MORE THAN 270 DEGREES OF TOTAL BEND. PULL
BOX PLACEMENTS AND SIZING BY CONTRACTOR. COORDINATE PULL BOX
LOCATIONS WITH ALL OBSTRUCTIONS, TRADES, AND VA AS REQUIRED.
9. ALL RECEPTACLES AND SWITCHES SHALL BE PROVIDED WITH PANEL AND CIRCUIT
LABELING LOCATED DIRECTLY ON THE WALL PLATE; IE:"P4-1", PANEL "4", CIRCUIT
"1". REFERENCE WIRING DEVICE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
Revisions: Date:
- 1/2" = 1'-0"
3 RM T4-02 - ELECTRICAL PLAN
- 1/2" = 1'-0"
4 RM T4-02 - LIGHTING AND RECEPTACLE PLAN
1'0 2' 4'
PROJECT
NORTH
1'0 2' 4'
PROJECT
NORTH
B
B
B
B
A
A
A
A
AAA
EP502
BB
BBBBBBB
AAA
AAAAAAA
BB
BBB
Mo
J
BBBBBB
B
B
B
EP502
A
A
AAAAAAA
AAAAAAAA
BB
BBBBBBB
Mo
A A
B B
A A
B B
AREA SHOWN
X
01S-T1-03B
01S-T1-03A
EP504
01S-FCU-07-T1-03 6
TR TOWER 1
T1-03
167 SF
P-TR-2A
P-TR-2B
BUS DUCT
"01S-BD-TWR1B"
EP506
BUS DUCT
"01S-BD-TWR1A"
EP506
01S-PA-15
01S-PB-16
01S-T1-03A-23
01S-T1-03A-23
ACCESS CONTROL
PANEL "01S-ACP-T1-03"
01S-T1-03A-10,12
BUS DUCT CIRCUIT BREAKER
"01S-BDCB-T1-03B"
BUS DUCT CIRCUIT BREAKER
"01S-BDCB-T1-03A"
D
D
T1-03
T4-03
X
L1
L1
L1L1
01S-T1-03B
01S-T1-03A
01S-T1-03A-4
TR TOWER 1
T1-03
167 SF
TYP.
EP508
EP508
P
EP504
TR TOWER 4
T4-03
160 SF
01S-FCU-08-T4-03 6
01S-T4-03B
01S-T4-03A
ACCESS CONTROL
PANEL "01S-ACP-T4-03"
D
D
01S-PA-06
P-TR-2A
01S-PB-07
BUS DUCT
"01S-BD-TWR4B"
EP506
EP506
BUS DUCT
"01S-BD-TWR4A"
01S-T4-03A-25
01S-T4-03A-10,12
BUS DUCT CIRCUIT BREAKER
"01S-BDCB-T4-03B"
BUS DUCT CIRCUIT BREAKER
"01S-BDCB-T4-03A"
01S-T4-03…