S06 - Amendment 0008 - ATT 8 - 260508 - Sheet 01S-AE452 TR Tower 4 Wall sections update.pdf

PDF 945 KB Posted

Attached to
EHRM Huntington VAMC 581-22-700 Construct Infrastructure Upgrades Federal contract opportunity
Solicitation number
36C77626R0025
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This document is an architectural drawing set for TR Tower 4 wall sections prepared by the U.S. Department of Veterans Affairs Office of Construction and Facilities Management. The drawing is dated 5/8/2026 and was prepared by SPEES Design Build, located at 23830 Pacific Highway S., Suite 300, Kent, WA 98032, serving as the Architect/Engineer of Record.

The detailed wall sections illustrate two primary construction conditions: an existing wall section and an exterior wall section, each drawn at 1/2" = 1'-0" scale. The drawings depict a multi-level structure spanning from Level 00G (0'-0") through the roof at 77'-10-1/2", with specific focus on TR Tower 4 components including towers T4-00G, T4-01, T4-02, and T4-05, each containing 160-166 square feet of space. Key construction details shown include spray-applied fireproofing at all structural members, a 2-hour rated mill finish aluminum floor expansion joint cover with 50% movement capability, cable trays, electrical panels, telecommunication racks, and lighting fixtures. Interior spaces identified include a Training Director Room (1,119 SF), mechanical rooms (4,245 SF), and multiple corridors. The drawing references coordination with Levels 3 and 4, which are omitted for clarity, and directs users to enlarged floor plans for detailed information on those levels.

View the file

Other files for this federal contract opportunity

Other files attached to EHRM Huntington VAMC 581-22-700 Construct Infrastructure Upgrades, newest first.
File Type Posted
S06 - 36C77626R0025 0008.pdf PDF
S06 - Amendment 0008 - ATT 3 - Civil OSP Redesign-signed.pdf PDF
S06 - Amendment 0008 - ATT 7 - 02EP100B - ELECTRICAL 20260413.pdf PDF
S06 - Amendment 0008 - ATT 12 - Environmental Report Huntington WV.pdf PDF
S06 - Amendment 0008 - ATT 13 - Hot Tapping Permit.pdf PDF
S06 - Amendment 0008 - ATT 1 - TechQuestionsVAresponses Final Set - Huntington EHRM IU.pdf PDF
S06 - Amendment 0008 - ATT 10 - 260508 - Sheet AD103-1B Data Center Phase 1B Demo Roof update.pdf PDF
S06 - Amendment 0008 - ATT 11 - Burn Permit.pdf PDF
S06 - Amendment 0008 - ATT 14 - Energized Electrical Work Permit.pdf PDF
S06 - Amendment 0008 - ATT 4 - Structural Set 04-21-2026.pdf PDF
S06 - 36C77626R0025 0007.pdf PDF
S06 - Amendment 0007 - ATT 1 - TechQuestionsVAresponses Partial 4 - Huntington EHRM IU.pdf PDF
S06 - Amendment 0007 - ATT 5 - Appendix A - PFC FPT.pdf PDF
S06 - 36C77626R0025 0006.pdf PDF
S06 - Amendment 0006 - ATT 1 - TechQuestionsVAresponses Partial 3 - Huntington EHRM IU.pdf PDF
S06 - 36C77626R0025 0005.pdf PDF
S06 - Amendment 0004 - ATT 2 - FAR 52.222-90 ADDRESSING DEI DISCRIMINATION BY FEDERAL CONTRACTORS - APR 2026.pdf PDF
S06 - Amendment 0004 - ATT 1 - TechQuestionsVAresponses Partial 2 - Huntington EHRM IU.pdf PDF
S06 - 36C77626R0025 0004.pdf PDF
S06 - Amendment 0003 - ATT 2 - TechQuestionsVAresponses Partial - Huntington EHRM IU.pdf PDF
S06 - 36C77626R0025 0003.pdf PDF
S06 - 36C77626R0025 0002.pdf PDF
S06 - Amendment 0001 - ATT 1 - Site Visit In-Sheet - Huntington EHRM IU.pdf PDF
S06 - 36C77626R0025 0001.pdf PDF
S02 - ATT 10 - 581-22-700 - 100 Drawings Part-8 of 24.pdf PDF
S02 - ATT 14 - 581-22-700 - 100 Drawings Part-12 of 24.pdf PDF
S02 - ATT 27 - 581-22-700 - Asbestos locations.xlsx XLSX spreadsheet
S02 - ATT 28 - 581-22-700 - FLS Compliance Letter.pdf PDF
S02 - 36C77626R0025.pdf PDF
S02 - ATT 1 - 581-22-700 - 100 Specifications Part-1 of 2.pdf PDF
S02 - ATT 2 - 581-22-700 - 100 Specifications Part-2 of 2.pdf PDF
S02 - ATT 9 - 581-22-700 - 100 Drawings Part-7 of 24.pdf PDF
S02 - ATT 11 - 581-22-700 - 100 Drawings Part-9 of 24.pdf PDF
S02 - ATT 15 - 581-22-700 - 100 Drawings Part-13 of 24.pdf PDF
S02 - ATT 18 - 581-22-700 - 100 Drawings Part-16 of 24.pdf PDF
S02 - ATT 20 - 581-22-700 - 100 Drawings Part-18 of 24.pdf PDF
S02 - ATT 23 - 581-22-700 - 100 Drawings Part-21 of 24.pdf PDF
S02 - ATT 24 - 581-22-700 - 100 Drawings Part-22 of 24.pdf PDF
S02 - ATT 30 - 581-22-700 - 100 Commissioning Plan.pdf PDF
S02 - ATT 3 - 581-22-700 - 100 Drawings Part-1 of 24.pdf PDF
S02 - ATT 4 - 581-22-700 - 100 Drawings Part-2 of 24.pdf PDF
S02 - ATT 5 - 581-22-700 - 100 Drawings Part-3 of 24.pdf PDF
S02 - ATT 6 - 581-22-700 - 100 Drawings Part-4 of 24.pdf PDF
S02 - ATT 7 - 581-22-700 - 100 Drawings Part-5 of 24.pdf PDF
S02 - ATT 17 - 581-22-700 - 100 Drawings Part-15 of 24.pdf PDF
S02 - ATT 19 - 581-22-700 - 100 Drawings Part-17 of 24.pdf PDF
S02 - ATT 22 - 581-22-700 - 100 Drawings Part-20 of 24.pdf PDF
S02 - ATT 26 - 581-22-700 - 100 Drawings Part-24 of 24.pdf PDF
S02 - ATT 33 - WD - WV20260048 - 01-02-2026.pdf PDF
S02 - ATT 35 - Site Visit Information - Huntington EHRM IU.pdf PDF
Show all 50

EHRM Huntington VAMC 581-22-700 Construct Infrastructure Upgrades has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LEVEL 00G

0' - 0"

LEVEL 00G

0' - 0"

LEVEL 01

11' - 9"

LEVEL 02

24' - 6 1/2"

LEVEL 05

64' - 6 1/2"

ROOF

77' - 10 1/2"

160 SF

TR TOWER 4

T4-02

160 SF

TR TOWER 4

T4-05

160 SF

TR TOWER 4

T4-01

166 SF

TR TOWER 4

T4-00G

CORRIDOR

694 SF

TRAINING

DIRECTOR ROOM

1B121

1119 SF

CORRIDOR

C2-11

696 SF

CORRIDOR

C5-4

1183 SF

MECHANICAL

ROOM

BB117

4245 SF

01S-A-513

01S-A-513

01S-A-513

TELECOMMUNIC

ATION RACK

CABLE TRAY

LIGHTING FIXTURE

ELECT PANEL

SPRAY APPLIED

FIREPROOFING AT

ALL STRUCT

MEMBERS

2HBCP-2-250

MILL FINISH ALUMINUM FLOOR

EXPANSION JOINT COVER

2 HOUR RATED WITH

MBF2H0350

UL LISTING FF-D-1071

50% MOVEMENT

TYPICAL AT EXISTING FLOOR

CONNECTION

2"

NOTE: WORK ON LEVELS 3 AND 4 ARE

SIMILAR TO ADJACENT LEVELS. THEY WERE

OMITTED FOR CLARITY TO SHOW ALL VIEWS

TOGETHER AT AN APPROPRIATE SCALE

FACTOR. SEE ENLARGED FLOOR PLANS FOR

DETAILED PLANS OF THOSE LEVELS

LEVEL 00G

0' - 0"

LEVEL 01

11' - 9"

ROOFDECK

18' - 0"

LEVEL 02

24' - 6 1/2"

LEVEL 05

64' - 6 1/2"

ROOF

77' - 10 1/2"

160 SF

TR TOWER 4

T4-05

160 SF

TR TOWER 4

T4-02

160 SF

TR TOWER 4

T4-01

166 SF

TR TOWER 4

T4-00G

PRE-FINISHED SHEET

METAL PARAPET CAP

FLASHING WITH

WATERTIGHT JOINT

ALUMINUM

BRACKET

ALUMINUM

BRACKET

T4-S1

SLAB ON GRADE

R-10 RIGID

INSULATION

VAPOR BARRIER

F2

E1C

R1

F2

F1

F2

01S-A-513

2'

4" CONCRETE CURB

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/8

/2

:5

:0

P

M

B

IM

/5

-2

-7

V

A H u n tin g to n

E H

R M

/B L D

G

S

T R

T O

W E

R .r v t

01S-AE452

TR TOWER 4 - WALL SECTIONS

01S

MA SR

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

1/2" = 1'-0"

TR TOWER 4 WALL SECTION - EXIST WALL

1/2" = 1'-0"

TR TOWER 4 WALL SECTION - EXTERIOR WALL

Revisions: Date:

Sheets
01S-AE452 - TR TOWER 4 - WALL SECTIONS

File details come from the government source that posted it. Updated .