S02 - ATT 6 - 581-22-700 - 100 Drawings Part-4 of 24.pdf

PDF 16 MB Posted

Attached to
EHRM Huntington VAMC 581-22-700 Construct Infrastructure Upgrades
Solicitation number
36C77626R0025
Issued by

About this file

This document set comprises architectural construction drawings and phasing plans for a renovation project at the VA Huntington Medical Center, specifically the EHRM Infrastructure Upgrades project (Project Number 581-22-700). The drawings are prepared by SPEES Design Build and cover Building 01W (Levels 00G, 01, 02, and 03) and Building 02 (Level 00B), with a focus on TR Tower 2, a new four-story vertical construction within the existing facility footprint.

The project involves demolition and renovation work organized into multiple phases with specific coordination requirements. TR Tower 2 consists of four levels: Level 00G contains a 115 SF privacy space and 164 SF examination room; Level 01 features a 160 SF examination room; Level 02 contains a 161 SF examination room; and Level 03 includes a 164 SF examination room with associated support spaces. The exterior design features brick veneer with aluminum T-furring over rigid insulation and metal studs, with horizontal slip joints and limestone parapet elements. Interior coordination includes ICRA (Infection Control Risk Assessment) phasing across Classes II through IV, with the contractor required to complete TR Tower 2 data drops in phases as directed by the Contracting Officer Representative (COR). Building sections, wall details, roof plans, and exterior elevations are provided showing fire-rated construction (1-hour and 2-hour rated walls), expansion joint covers, thru-wall scuppers, and coordination with existing building infrastructure. The fully sprinklered facility includes specific provisions for temporary exhaust location and window sealing during construction.

View the file

Other files

File Type Posted
S06 - 36C77626R0025 0008.pdf PDF
S06 - Amendment 0008 - ATT 7 - 02EP100B - ELECTRICAL 20260413.pdf PDF
S06 - Amendment 0008 - ATT 11 - Burn Permit.pdf PDF
S06 - Amendment 0008 - ATT 10 - 260508 - Sheet AD103-1B Data Center Phase 1B Demo Roof update.pdf PDF
S06 - Amendment 0008 - ATT 9 - 260508 - Sheet AD101-1B Data Center Phase 1B Demo Floor Plan update.pdf PDF
S06 - Amendment 0008 - ATT 1 - TechQuestionsVAresponses Final Set - Huntington EHRM IU.pdf PDF
S06 - Amendment 0008 - ATT 14 - Energized Electrical Work Permit.pdf PDF
S06 - Amendment 0008 - ATT 5 - ELECTRICAL 2026.04.13.pdf PDF
S06 - Amendment 0008 - ATT 6 - 01WEP100G - ELECTRICAL 20260413.pdf PDF
S06 - Amendment 0008 - ATT 3 - Civil OSP Redesign-signed.pdf PDF
S06 - Amendment 0008 - ATT 12 - Environmental Report Huntington WV.pdf PDF
S06 - Amendment 0008 - ATT 8 - 260508 - Sheet 01S-AE452 TR Tower 4 Wall sections update.pdf PDF
S06 - Amendment 0008 - ATT 13 - Hot Tapping Permit.pdf PDF
S06 - Amendment 0008 - ATT 2 - UPDATED SHEETS.pdf PDF
S06 - Amendment 0008 - ATT 4 - Structural Set 04-21-2026.pdf PDF
S06 - 36C77626R0025 0007.pdf PDF
S06 - Amendment 0007 - ATT 1 - TechQuestionsVAresponses Partial 4 - Huntington EHRM IU.pdf PDF
S06 - Amendment 0007 - ATT 3 - Lift Planning.pdf PDF
S06 - Amendment 0007 - ATT 2 - Geotechnical Report.pdf PDF
S06 - Amendment 0007 - ATT 5 - Appendix A - PFC FPT.pdf PDF
S06 - Amendment 0007 - ATT 4 - 01 00 00 - GENERAL REQUIREMENTS_A1.pdf PDF
S06 - Amendment 0007 - ATT 6 - Crane lift Info.pdf PDF
S06 - 36C77626R0025 0006.pdf PDF
S06 - Amendment 0006 - ATT 1 - TechQuestionsVAresponses Partial 3 - Huntington EHRM IU.pdf PDF
S06 - 36C77626R0025 0005.pdf PDF
S06 - Amendment 0004 - ATT 2 - FAR 52.222-90 ADDRESSING DEI DISCRIMINATION BY FEDERAL CONTRACTORS - APR 2026.pdf PDF
S06 - Amendment 0004 - ATT 1 - TechQuestionsVAresponses Partial 2 - Huntington EHRM IU.pdf PDF
S06 - 36C77626R0025 0004.pdf PDF
S06 - Amendment 0003 - ATT 2 - TechQuestionsVAresponses Partial - Huntington EHRM IU.pdf PDF
S06 - 36C77626R0025 0003.pdf PDF
S06 - 36C77626R0025 0002.pdf PDF
S06 - Amendment 0001 - ATT 1 - Site Visit In-Sheet - Huntington EHRM IU.pdf PDF
S06 - 36C77626R0025 0001.pdf PDF
S02 - ATT 28 - 581-22-700 - FLS Compliance Letter.pdf PDF
S02 - ATT 3 - 581-22-700 - 100 Drawings Part-1 of 24.pdf PDF
S02 - ATT 15 - 581-22-700 - 100 Drawings Part-13 of 24.pdf PDF
S02 - ATT 30 - 581-22-700 - 100 Commissioning Plan.pdf PDF
S02 - ATT 20 - 581-22-700 - 100 Drawings Part-18 of 24.pdf PDF
S02 - ATT 24 - 581-22-700 - 100 Drawings Part-22 of 24.pdf PDF
S02 - ATT 1 - 581-22-700 - 100 Specifications Part-1 of 2.pdf PDF
S02 - ATT 10 - 581-22-700 - 100 Drawings Part-8 of 24.pdf PDF
S02 - ATT 12 - 581-22-700 - 100 Drawings Part-10 of 24.pdf PDF
S02 - ATT 23 - 581-22-700 - 100 Drawings Part-21 of 24.pdf PDF
S02 - ATT 31 - 581-22-700 - Topographic Survey TR Tower 3.pdf PDF
S02 - ATT 25 - 581-22-700 - 100 Drawings Part-23 of 24.pdf PDF
S02 - ATT 16 - 581-22-700 - 100 Drawings Part-14 of 24.pdf PDF
S02 - ATT 21 - 581-22-700 - 100 Drawings Part-19 of 24.pdf PDF
S02 - ATT 34 - HEFP SEP Design Alerts 1-9 and 11-16.pdf PDF
S02 - ATT 29 - 581-22-700 - Geotechnical Report - W24044 - VA Duct Bank 11.21.24.pdf PDF
S02 - ATT 14 - 581-22-700 - 100 Drawings Part-12 of 24.pdf PDF
Show 40 more

Latest 50 of 68 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C

X

W

WAP

360°

TO DEMOLISH

EXISTING DOOR TO REMAIN

EXISTING DOOR TO DEMOLISH

NEW DOOR

SMOKE RATED WALL

NEW LIGHTS (SEE ELECTRICAL DETAILS)

KEY AREA SHOWN

PROJECT

NORTH

FOOTPRINT OF NEW

CONSTRUCTION.

PREPARE AREA FOR

NEW CONSTRUCTION.

FOOTPRINT OF NEW

CONSTRUCTION.

TEMPORARY LOCATION OF EXHAUST.

MOVE INSIDE NEW TR ONCE FEASIBLE.

SEAL WINDOW DURING

CONSTRUCTION

SEAL WINDOW DURING

CONSTRUCTION

T2-B

T2-SB

T2-A

T2-1

T2-2 11

3/

8"

/8

7'

LINE OF NEW

CONSTRUCTION

LINE OF NEW

CONSTRUCTION.

T2-B

T2-SB

T2-A

T2-1

T2-2

SEE GENERAL NOTES

1, 2 AND 6

NEW

FLOORING

E X

IS

T

IN

G

F

LO

O R

IN

G

T2-S1

T2-S2

T2-SA

T2-B

GC128g

115 SF

PRIVACY

GC134

112 SF

CORRIDOR

1280 SF

STAFF

RESTROOM

GC137

157 SF

STAFF

RESTROOM

GC136

187 SF

164 SF

TR TOWER 2

T2-00G

E1C

01WA-103c

01WA-103c

01WA-103b

01WA-103b

01WA-103b

E1C

DATA RACK

ELECT PANEL

E1C

EXPANSION

JOINT

EXPANSION

JOINT

T2-SB

T2-A

T2-1

T2-2

IN-03.01-4

T2-00G

1/

2"

7/ 8"

1/

2"6"

/4

12' - 2 3/8"

6"6"

1'

1"

8 8

02b

3' - 9 1/2"

2'

4"

04a 04a

6"

IN-01.31

EXPOSED

T2-S1

T2-S2

T2-SA

T2-B

GC128g

115 SF

PRIVACY

GC134

112 SF

CORRIDOR

1280 SF

STAFF

RESTROOM

GC137

157 SF

STAFF

RESTROOM

GC136

187 SF

01WA-103c

01WA-103c

T2-SB

T2-A

T2-1

T2-2

164 SF

TR TOWER 2

T2-00G

SEE GENERAL NOTES

1, 2 AND 6

SEE GENERAL NOTES

1, 2 AND 6

AC UNIT

1' - 7"

2'

2"

6"

1' - 7"

1' - 9"

2'

2"

2'

2" 1' - 9"

STAFF

RESTROOM

GC136

187 SF

STAFF

RESTROOM

GC137

157 SF

PRIVACY

GC134

112 SF

GC128g

115 SF

( + ) PRESSURE

CONSTRUCTION ZONE, (--) PRESSURE

TEMPORARY ICRA BARRIER

TEMPORARY ICRA DOOR

CONSTRUCTION TACKY MAT

HEPA EQUIPPED EXHAUST

TR TOWER 2

01W

0223R 01S

01A

NFPA

TABLE 7.2.1.1 FIRE RESISTANCE RATING FOR TYPE I - 332 (HR)

COLUMNS

SUPPORTING MORE THAN ONE FLOOR 3 HOUR

SUPPORTING ONE FLOOR / ROOF ONLY 2 HOUR

BEAMS

SUPPORTING ONE FLOOR / ROOF ONLY 2 HOUR

FLOOR/CEILING ASSEMBLIES 2 HOUR

ROOF/CEILING ASSEMBLIES 1 1/2 HOUR

INTERIOR/EXTERIOR NONBEARING WALLS 0 HOUR

FIRE RATED REQUIREMENTS

FIRE RATING SCHEDULE

UL

REFERENCE

COLUMNS SUPPORTING ONE FLOOR

HOURLY

RATINGTYPE ELEMENT

I 2 HR UL X854

I COLUMNS SUPPORTING MORE

THAN ONE FLOOR

3 HR UL X854

COLUMNS SUPPORTING ROOFI 2 HR UL X854

FLOOR DECKSI 2 HR UL D779

FLOOR SUPPORTSI 2 HR UL P732

ROOF DECKSI 1 1/2 HR UL P732

ROOF SUPPORTSI 2 HR UL N732

FIRE RATED SCHEDULE

STAFF

RESTROOM

GC136

187 SF

STAFF

RESTROOM

GC137

157 SF

PRIVACY

GC134

112 SF

GC128g

115 SF

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0 /2

:0

:3 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n E

H R

M /B

L D

G

W

T R

T O

W E

R

.r v t

01WA-100G

BUILDING 01W - LEVEL 00G - DEMO, FLOOR

PLANS & RCPS

01W

MA SR/RB

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

1. ALL PRODUCTS AND FINISHES SHALL MATCH EXISTING OR

ADJACENT EXISTING UNLESS OTHERWISE NOTED.

2. PATCH AND REPAIR WALLS, FLOORS AND CEILINGS

WHERE MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS

ARE DEMOLISHED.

3. PROTECT FINISHES IN ROOMS ADJACENT TO THE AREA OF

WORK AND PARTS THAT ARE NOT INCLUDED IN THE

SCOPE.

4. CONTRACTOR SHALL LEAVE FIRE RATING STAMP

UNPAINTED AND VISIBLE ON THE NEW INSTALLED FRT

PLYWOOD. SEE DETAIL 5/AE401.

5. REFER TO SHEET AS101 FOR ICRA REQUIREMENTS AND

DETAILS.

6. PATCH AND REPAIR CEILING, WALLS AND FLOORS AS

REQUIRED WHERE ICRA BARRIERS WILL BE CONSTRUCTED

AND REMOVED.

7. REFER TO SHEET A-602 FOR DOOR SCHEDULE.

1/4" = 1'-0"

LEVEL 00G - TR TOWER 2 - DEMO FLOOR PLAN

PROJECT

NORTH

1/4" = 1'-0"

LEVEL 00G - TR TOWER 2 - DEMO RCP

PROJECT

NORTH

1/4" = 1'-0"

RM T2-00G - FLOOR PLAN

1/4" = 1'-0"

RM T2-00G - RCP

PROJECT

NORTH

PROJECT

NORTH

9 INSTALL TEMPORARY 1 HR CONSTRUCTION ICRA BARRIER

TO SEPARATE CONSTRUCTION AREA FROM OCCUPIED

SPACE.

10 INSTALL FIRE RESISTANT TEMPORARY SELF-CLOSING DOOR,

SOLID CORE WOOD IN STEEL FRAME, PAINTED, AT OPENING

AND MATCH RATING OF ICRA BARRIER, TYPICAL.

11 PLACE TACKY MATS AT ENTRANCE AND EXIT OF

CONSTRUCTION AREA, MINIMUM SIZE 24"x36", TYPICAL.

1 DEMOLISH EXISTING WALL. PATCH EXPOSED WALL

INTERSECTIONS TO MATCH EXISTING.

2 DEMOLISH PORTION OF EXISTING WALL. PREPARE FOR NEW

DOOR/FRAME.

3 INSTALL NEW DOOR/FRAME.

4 CONSTRUCT NEW WALL.

5 CONSTRUCT NEW FLOOR.

6 APPLY ANTI-STATIC COATING TO EXPOSED FLOOR. PROVIDE

VINYL REDUCER STRIP AT EXISTING FLOORING TRANSITION.

7 INSTALL NEW RESILIENT RUBBER BASE AT ROOM

PERIMETER WITH SEALANT AT THE BOTTOM.

8 INSTALL FRT PLYWOOD OVER WALLS AS NEEDED PER

DETAIL 3/AE401, TYPICAL.

GENERAL NOTES

KEY PLAN

KEY NOTES (THIS SHEET ONLY)

LEGEND

ICRA KEYNOTES

ICRA CLASS III LEGEND

Revisions: Date:

09/03/20259/3/2025 113 OF 693

TR

ICRA PHASING LINE

ICRA CLASS III

ICRA CLASS IV

ICRA CLASS II

FIRE EXTINGUISHER CABINETFEC

FIRE EXTINGUISHERFE

BUILDING BOUNDARY LINE

2 HR FIRE RATED WALL

1 HR FIRE RATED WALL

SMOKE RATED WALL

KEY AREA SHOWN

PROJECT

NORTH

X Y Z

A16 A15 A14

A7 A6

A5 A4

A3

A8

A11 A10

A9

A2 A1

T2-A

T2-1 T2-B

T2-2

1528 SF

KITCHEN

1D102

195 SF

NOURISH

1D101

48 SF

ELEV

F8

29 SF

1D102A

275 SF

EXAM

1C131

203 SF

EXAM

1C132

205 SF

EXAM

1C135

TLT

SHWR

1C135A

205 SF

EXAM

1C136

168 SF

EXAM

1C

16 SF

TLT

1C138A

27 SF

TLT

1C140A

170 SF

EXAM

1C140

209 SF

EXAM

1C143

45 SF

TLT

SHWR

1C143A

210 SF

EXAM

1C

193 SF

EXAM

1C

242 SF

EXAM

1C149

251 SF

EXAM

1C150

184 SF

EXAM

1C152

115 SF

EXAM

1C153

115 SF

EXAM

1C156

264 SF

EXAM

1C159

253 SF

MMS ADMIN

1C160

237 SF

BRK

NURSE RM

1C160A

139 SF

LPN

1C160B

81 SF

MALE TOILET

1C161B

80 SF

FEMALE TOILET

1C161A

130 SF

OFFICE

1C162

78 SF

MALE LOCKER

1C163

29 SF

TOILET

32 SF

TOILET

FEMALE

LOCKER

1C164

189 SF

VISN HR

1C165

104 SF

PATIENT REP

1C166A179 SF

PATIENT REP

1C166

144 SF

PATIENT REP

1C167

88 SF

MECH

1C168

518 SF

LOBBY

1C100216 SF

SWITCHBOARD

1C101

180 SF

CHAPLAIN

OFFICE

1C102226 SF

CHAPLAIN SECY

1C104

152 SF

CHAPLAIN

1C104A

12 SF

COMM

1C146

56 SF

ELEC

1C144

117 SF

IRM

1C142

123 SF

NURSES

1C141

70 SF

SOILED

1C154

78 SF

CLEAN

1C155

30 SF

TOIL

1C139C

75 SF

MECH

1C139D

47 SF

EQUIP

1C161C

KIT

1C139A

110 SF

MED ROOM

1C139B

8 SF

MECH

45 SF

1C123

37 SF

HAC

1C134

235 SF

EXAM

1C

1453 SF

STAIR

25 SF

1C151A

182 SF

EXAM

1C151

26 SF

1C153A

24 SF

1C158A

263 SF

EXAM

1C158

294 SF

RECEPTIONIST

1C139

289 SF

CLINIC

MANAGER

655 SF

WAITING

1C161

205 SF

STAIR

178 SF

TIME KEEPER

1C107

H.A.C.

1C107A

TLT

100 SF

NURSE RECRUIT

1C108 59 SF

ELEC

1C109

228 SF

PROSTHETICS

1C110

125 SF

PROSTHETICS

1C111

195 SF

STAIR

SHOWER

1C116A

117 SF

CLINICAL

PHARMACY

1C112

168 SF

PHARMACY

RESIDENT

1C113

141 SF

DIETETICS

1C114

FEMALE TOILET

1C116

FEMALE

LOCKER

1C115

131 SF

EEO

1C117

111 SF

EEO

1C118

181 SF

EEO

1C119

117 SF

EEO

1C120

20 SF

1C120A

61 SF

ELEC

1C121

84 SF

IRM

1C123

197 SF

STAIR

104 SF

BIOMED

1C124

148 SF

CLINIC

1C125

114 SF

NUT

1C127

107 SF

NUT?

1C127A

151 SF

C&P CHIEF

1C126A

260 SF

C & P

1C126

C&P NURSE

1C128

CLINICAL

PHARMACIST

1C129

CLINICAL

PHARMACIST

1C130

HAC

1C114A

882 SF

CORRIDOR

C1-26

180 SF

STAIR

205 SF

LOUNGE

1D107

178 SF

FOREMAN

1D104

151 SF

COOLER

C1-30

238 SF

CANNED GOODS

1D103

109 SF

WORK

1D110

FEMALE TOILET

1D108

225 SF

TRAINING

1D111

166 SF

SUPERV.

2D111A

MEN TOILET

1D109

155 SF

STORAGE

1D105

90 SF

STOR

1D106

469 SF

FOOD SERVICE

LINE

717 SF

DISHWASHING

1D100A

22 SF

TEL

1C122

2034 SF

CORRIDOR

C1-19

98 SF

ELEV

P9

77 SF

ELEV

W -1

77 SF

ELEV

W -2

CORR.

1087 SF

BLDG. 2

DIETETICS

C1-31

E-6

S-3

E-5

S-4

BUILDING 01W

PHASE 1:

CONTRACTOR TO COMPLETE THE WORK OF THIS TR AND

ASSOCIATED DATA DROPS. COMPLETE ONE SECTION AT

A TIME AS DIRECTED TO COR.

BUILDING 01W

SECTION 1A:

CONTRACTOR TO COORDINATE WITH VA FOR

ROOM CLOSURES AND AVAILABILITY TO COMPLETE

DATA WIRING IN THIS AREA.

BUILDING 01W

SECTION 1B:

CONTRACTOR TO COORDINATE WITH VA FOR ROOM

CLOSURES AND AVAILABILITY TO COMPLETE DATA

WIRING IN THIS AREA.

BUILDING 01

SECTION 1C:

CONTRACTOR TO COORDINATE WITH VA FOR ROOM

CLOSURES AND AVAILABILITY TO COMPLETE DATA

WIRING IN THIS AREA.

BUILDING 02

SECTION 1D:

CONTRACTOR TO COORDINATE WITH VA FOR ROOM

CLOSURES AND AVAILABILITY TO COMPLETE DATA

WIRING IN THIS AREA.

BLDG. 01

BLDG. 01W

BLDG. 02

TR TOWER 2

T2-01

160 SF

BLDG. 01S

BLDG. 01A

191 SF

EXAM

1C131

NEW SEMI-RECESSED FEC, TO MATCH

OR EXCEED EXISTING EXTINGUISHER IN

ABC RATING AND SIZE. SEE DET 4/A-604.

FEC

1W-1

1W-2

1W-3

1W-4

1W-5

1W-6

SPACE FOR NEW DATA CENTER

TR TOWER 2

01W

0223R 01S

01A 01

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0

/2

:5

:5 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n E

H R

M /B

L D

G

L E

V E

L

.r v t 01WAS101

BUILDING 01W - LEVEL 01 - PHASING PLAN

01W

MA RB

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

KEY PLAN

LEGEND

PROJECT

NORTH

1/16" = 1'-0"

BUILDING 01W - LEVEL 01 - PHASING PLAN

09/03/20259/3/2025 114 OF 693

360°

X

W

360°

TO DEMOLISH

EXISTING DOOR TO REMAIN

EXISTING DOOR TO DEMOLISH

NEW DOOR

SMOKE RATED WALL

NEW LIGHTS (SEE ELECTRICAL DETAILS)

KEY AREA SHOWN

PROJECT

NORTH

T2-B

FOOTPRINT OF NEW

CONSTRUCTION.

PREPARE AREA FOR

NEW CONSTRUCTION.

FOOTPRINT OF NEW

CONSTRUCTION.

SEAL WINDOW DURING

CONSTRUCTION

SEAL WINDOW DURING

CONSTRUCTION

TEMPORARY LOCATION OF EXHAUST.

MOVE INSIDE NEW TR ONCE FEASIBLE.

T2-SB

T2-A

T2-1

T2-2

11' - 8 1/2"

ANTE

ROOM

T2-B

LINE OF NEW

CONSTRUCTION

LINE OF NEW

CONSTRUCTION.

T2-SB

T2-A

T2-1

T2-2

T2-S1

T2-S2

T2-SA

T2-B

160 SF

TR TOWER 2

T2-01

EXAM

1C132

203 SF

CORRIDOR

C1-26

882 SF

CLINICAL

PHARMACIST

1C130

96 SF

CLINICAL

PHARMACIST

1C129

105 SF

01WA-103c

01WA-103c

01WA-103b

01WA-103b

01WA-103b

10' - 9 1/2" CLEARANCE

5 7/8"

5 1/2"

7' - 9"

3' - 6"

DATA RACK

ELECT PANEL

E1C

E1C

E1C

T2-01

EXISTING

FLOORING

N E W

O R

IN

G

T2-SB

FACE OF STUDS

T2-A

T2-1

T2-2

12' - 2 3/8"

6"

1/

2"

7/ 8"

1/

2"

6"

/4

4 1/4"WALL TO WALL

EXPANSION JOINT

COVER

WALL TO WALL

EXPANSION JOINT

COVER

C

LE

A R

A N

C E

IN-03.01-7

AE501

02b

IN-01.02

04a

T2-S1

T2-S2

T2-SA

T2-B

160 SF

TR TOWER 2

T2-01

EXAM

1C132

203 SF

CORRIDOR

C1-26

882 SF

CLINICAL

PHARMACIST

1C130

96 SF

CLINICAL

PHARMACIST

1C129

105 SF

01WA-103c

01WA-103c

EXPOSED

T2-SB

T2-A

T2-1

T2-2

AC UNIT

1' - 11"

1'

1'

1' - 11"

1'

1' - 11"

2"

1' - 11"

TR TOWER 2

01W

0223R 01S

01A 01

EXAM

1C132

203 SF

CORRIDOR

C1-26

882 SF

CLINICAL

PHARMACIST

1C130

96 SF

CLINICAL

PHARMACIST

1C129

105 SF

EXAM

1C131

191 SF EXAM

1C132

203 SF

CORRIDOR

C1-26

882 SF

CLINICAL

PHARMACIST

1C130

96 SF

CLINICAL

PHARMACIST

1C129

105 SF

EXAM

1C131

191 SF

NFPA

TABLE 7.2.1.1 FIRE RESISTANCE RATING FOR TYPE I - 332 (HR)

COLUMNS

SUPPORTING MORE THAN ONE FLOOR 3 HOUR

SUPPORTING ONE FLOOR / ROOF ONLY 2 HOUR

BEAMS

SUPPORTING ONE FLOOR / ROOF ONLY 2 HOUR

FLOOR/CEILING ASSEMBLIES 2 HOUR

ROOF/CEILING ASSEMBLIES 1 1/2 HOUR

INTERIOR/EXTERIOR NONBEARING WALLS 0 HOUR

FIRE RATED REQUIREMENTS

FIRE RATING SCHEDULE

UL

REFERENCE

COLUMNS SUPPORTING ONE FLOOR

HOURLY

RATINGTYPE ELEMENT

I 2 HR UL X854

I COLUMNS SUPPORTING MORE

THAN ONE FLOOR

3 HR UL X854

COLUMNS SUPPORTING ROOFI 2 HR UL X854

FLOOR DECKSI 2 HR UL D779

FLOOR SUPPORTSI 2 HR UL P732

ROOF DECKSI 1 1/2 HR UL P732

ROOF SUPPORTSI 2 HR UL N732

FIRE RATED SCHEDULE

+ POSITIVE ( + ) PRESSURE

CONSTRUCTION ZONE (--) PRESSURE

ANTE ROOM ( - ) PRESSURE

TEMPORARY ICRA BARRIER

TEMPORARY ICRA DOOR

CONSTRUCTION TACK MAT

HEPA EQUIPED EXHAUST

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0 /2

:0

:3 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n E

H R

M /B

L D

G

W

T R

T O

W E

R

.r v t

01WA-101

BUILDING 01W - LEVEL 01 - DEMO, FLOOR

PLANS & RCPS

01W

MA SR/RB

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

1. ALL PRODUCTS AND FINISHES SHALL MATCH EXISTING OR

ADJACENT EXISTING UNLESS OTHERWISE NOTED.

2. PATCH AND REPAIR WALLS, FLOORS AND CEILINGS

WHERE MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS

ARE DEMOLISHED.

3. PROTECT FINISHES IN ROOMS ADJACENT TO THE AREA OF

WORK AND PARTS THAT ARE NOT INCLUDED IN THE

SCOPE.

4. CONTRACTOR SHALL LEAVE FIRE RATING STAMP

UNPAINTED AND VISIBLE ON THE NEW INSTALLED FRT

PLYWOOD. SEE DETAIL 5/AE401.

5. REFER TO SHEET AS101 FOR ICRA REQUIREMENTS AND

DETAILS.

6. PATCH AND REPAIR CEILING, WALLS AND FLOORS AS

REQUIRED WHERE ICRA BARRIERS WILL BE CONSTRUCTED

AND REMOVED.

7. REFER TO SHEET A-602 FOR DOOR SCHEDULE.

PROJECT

NORTH

PROJECT

NORTH

PROJECT

NORTH

PROJECT

NORTH

GENERAL NOTES

KEY PLAN

KEY NOTES (THIS SHEET ONLY)

LEGEND

1/4" = 1'-0"

LEVEL 01 - TR TOWER 2 - DEMO FLOOR PLAN

1/4" = 1'-0"

LEVEL 01 - TR TOWER 2 - DEMO RCP

1/4" = 1'-0"

RM T2-01 - FLOOR PLAN

1/4" = 1'-0"

RM T2-01 - RCP

9 INSTALL TEMPORARY 1 HR CONSTRUCTION ICRA BARRIER

TO SEPARATE CONSTRUCTION AREA FROM OCCUPIED

SPACE.

10 INSTALL FIRE RESISTANT TEMPORARY SELF-CLOSING DOOR,

SOLID CORE WOOD IN STEEL FRAME, PAINTED, AT OPENING

AND MATCH RATING OF ICRA BARRIER, TYPICAL.

11 PLACE TACKY MATS AT ENTRANCE AND EXIT OF

CONSTRUCTION AREA, MINIMUM SIZE 24"x36", TYPICAL.

1 DEMOLISH EXISTING WALL. PATCH EXPOSED WALL

INTERSECTIONS TO MATCH EXISTING.

2 DEMOLISH EXISTING DOOR/FRAME. PREPARE FOR NEW

DOOR/FRAME.

3 INSTALL NEW DOOR/FRAME.

4 CONSTRUCT NEW WALL.

5 CONSTRUCT NEW FLOOR.

6 APPLY ANTI-STATIC COATING TO EXPOSED FLOOR. PROVIDE

VINYL REDUCER STRIP AT EXISTING FLOORING TRANSITION.

7 INSTALL NEW RESILIENT RUBBER BASE AT ROOM

PERIMETER WITH SEALANT AT THE BOTTOM.

8 INSTALL FRT PLYWOOD OVER WALLS AS NEEDED PER

DETAIL 3/AE401, TYPICAL.

ICRA KEYNOTES

Revisions: Date:

ICRA CLASS IV LEGEND

09/03/20259/3/2025 115 OF 693

X Y Z

A16 A15 A14

A7 A6

A5 A4

A3

A8

A11 A10

A9

1W-6

1W-5

A2 A1

T2-A

T2-B

T2-1

T2-2

96 SF

EXAM 7

2C154

100 SF

EXAM 7

2C156

90 SF

EXAM 7

2C158

88 SF

EXAM 7

2C160

99 SF

EXAM 6

2C162

99 SF

EXAM 6

2C163

98 SF

SOILED 245

2C153

93 SF

TELEHEALTH

2C152

93 SF

SOCIAL WK

2C151

143 SF

DIETITIAN

2C150

89 SF

PHARMACY

2C148

16 SF

COMM

2C149A

56 SF

ELEC

2C14784 SF

IRM

2C145

216 SF

STAIRS

145 SF

BARIATRIC/

SPINAL EXAM 4

2C146

104 SF

EXAM 4

2C144

118 SF

EXAM 4

2C142

146 SF

EXAM 4

2C140

126 SF

PHLEB EKG

2C143

49 SF

PHLEB TOILET

2C141

44 SF

MED

2C161

77 SF

WOMEN'S

TOILET

2C139

105 SF

NURSE MGR

2C168

76 SF

CLEAN SUPPLY

2C165

89 SF

MENTAL

HEALTH

2C155

61 SF

TELERETINAL

2C15750 SF

STAFF TLT

2C167

124 SF

MEN'S TOILET

2C137

100 SF

EXAM 6

2C164

97 SF

EXAM 6

2C166103 SF

EXAM 5

2C170

EXAM 5

2C176

EXAM 5

2C174

224 SF

STAFF LOUNGE

2c177

125 SF

CLERKS 3 & 4

2C138

323 SF

RECEPTION 3 &

2C136

138 SF

EXAM 3

2C135

126 SF

EXAM 3

2C134

105 SF

EXAM 3

2C133

107 SF

EXAM 3

2C132

83 SF

PHARMACY

2C131

117 SF

EXAM 1

2C128

104 SF

EXAM 1

2C127

105 SF

EXAM 1

2C126

109 SF

EXAM 1

2C125

53 SF

2c129

38 SF

2c135a

77 SF

ELEV

W-1

145 SF

EXAM 2

2C124

77 SF

ELEV

W-2

CLEAN LINEN

MED. EQUIP.

1028 SF

C4

C4

EXAM 5

2C172

RECEPTION 5, 6,

& 7

2C173

217 SF

CLERKS 5, 6, & 7

2C169

114 SF

CLERKS 1&2

2C120A

146 SF

RECEPTION 1&2

2C120

87 SF

EXAM 2

2C121

109 SF

EXAM 2

2C122

81 SF

EXAM 2

2C123

316 SF

C1

2c183

108 SF

EXAM - 18

2c178

137 SF

EXAM - 19

2c179

140 SF

EXAM - 20

2c180

136 SF

EXAM - 17

2c175c

129 SF

EXAM - 14

2c175a

84 SF

TOILET

2c175d

69 SF

TOILET

2c175e

182 SF

ONCOLOGY

OFFICE

2c182

169 SF

EXAM - 21

2c18144 SF

HAC

SECURE

2c182a184 SF

RECEPTIONIST -

2C100

62 SF

MECH

2c184

61 SF

FEMALE

2C115

95 SF

MEN

2C116

79 SF

COMM.

CLOSET

2C117

31 SF

TLT

2C118A

155 SF

CHEMOTHERAPY

2C118

30 SF

ELEC

2C119A

46 SF

ELEC

2C119 117 SF

EXAM ROOM - 11

209 SF

STAIR

555 SF

ONCOLOGY

SUITE

2c175b

36 SF

VESTIBULE

2C123

193 SF

STAIR

120 SF

EXAM - 10

2C114

108 SF

EXAM - 9

2C113

118 SF

EXAM - 8

2C112

116 SF

EXAM - 7

2C111

125 SF

EXAM - 6

2C110

179 SF

EXAM 5

2C109

64 SF

E - 6

72 SF

E - 5

119 SF

ELEVATOR

LOBBY

342 SF

GROUP PATIENT

RM.

2c171

554 SF

WAITING AREA

-1

2C100A108 SF

B.M.E. OFFICE

116 SF

DIA. SUPPORT

2C102A

117 SF

NURSING

2C108

132 SF

EXAM - 4

2C107

129 SF

EXAM - 3

2C106

118 SF

EXAM - 2

2C105

64 SF

DIALYSIS

STOR-1

2C104

324 SF

CHAIR-DIALYSIS

2C102

181 SF

SPECIAL EKG

EXAM - 1

2C103

206 SF

STAIR

1161 SF

CORRIDOR - 1

172 SF

WAITING RM. - 2

2c175

387 SF

CORRIDOR - 1

1225 SF

C3

2A101c

HAC

1C111a

1042 SF

CORRIDOR

C2-35

98 SF

ELEV

P9

180 SF

STR

124 SF

OFFICE

2D115

253 SF

SECY

2D115A139 SF

OFFICE

2D116

188 SF

OFFICE

2D116A

126 SF

HSS

2D114

247 SF

DR. OFFICE

2D113

146 SF

LOUNGE

2D112

58 SF

F. TLT

2D111

97 SF

OFFICE

2D112A

2D109

22 SF

HAC

2D110

200 SF

OFFICE

2D105

109 SF

OFFICE

2D104

147 SF

MEN

2D108

166 SF

OFFICE

2D106

226 SF

FAN/ELEV RM

2D107

119 SF

OFFICE

2D106A

173 SF

OFFICE

2D103

150 SF

DR. OFFICE

2D103A

120 SF

WORK

2D102

155 SF

OFFICE

2D101A

187 SF

OFFICE

2D101

152 SF

OFFICE

2D100

627 SF

BLDG 2

C5

2C177

12 SF

2C149

BUILDING 01W

PHASE 1:

CONTRACTOR TO COMPLETE THE WORK OF THIS TR AND

ASSOCIATED DATA DROPS. COMPLETE ONE SECTION AT A

TIME AS DIRECTED TO COR.

BUILDING 01W

SECTION 1A:

CONTRACTOR TO COORDINATE WITH VA FOR ROOM

CLOSURES AND AVAILABILITY TO COMPLETE DATA

WIRING IN THIS AREA.

BUILDING 01W

SECTION 1B:

CONTRACTOR TO COORDINATE WITH VA FOR ROOM

CLOSURES AND AVAILABILITY TO COMPLETE DATA

WIRING IN THIS AREA.

BUILDING 01 & 01W

SECTION 1C:

CONTRACTOR TO COORDINATE WITH VA FOR ROOM

CLOSURES AND AVAILABILITY TO COMPLETE DATA

WIRING IN THIS AREA.

BUILDING 02

SECTION 1D:

CONTRACTOR TO COORDINATE WITH VA FOR ROOM

CLOSURES AND AVAILABILITY TO COMPLETE DATA

WIRING IN THIS AREA.

BLDG. 02

BLDG. 01W

BLDG. 01

TR TOWER 2

T2-02

161 SF

BLDG. 01A

BLDG. 01S

FEC

NEW SEMI-RECESSED FEC, TO MATCH

OR EXCEED EXISTING EXTINGUISHER IN

ABC RATING AND SIZE. SEE DET 4/A-604.

1W-1

1W-2

1W-3

1W-4

SPACE FOR NEW DATA CENTER

TR

ICRA PHASING LINE

ICRA CLASS III

ICRA CLASS IV

ICRA CLASS II

FIRE EXTINGUISHER CABINETFEC

FIRE EXTINGUISHERFE

BUILDING BOUNDARY LINE

2 HR FIRE RATED WALL

1 HR FIRE RATED WALL

SMOKE RATED WALL

KEY AREA SHOWN

PROJECT

NORTH

TR TOWER 2

01W

0223R 01S

01A 01

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0

/2

:1

:4 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n E

H R

M /B

L D

G

L E

V E

L

.r v t 01WAS102

BUILDING 01W - LEVEL 02 - PHASING PLAN

01W

MA RB

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTION, WV 25704-9300

1/16" = 1'-0"

BUILDING 01W - LEVEL 02 - PHASING PLAN

KEY PLAN

LEGEND

PROJECT

NORTH

09/03/20259/3/2025 116 OF 693

X

W

360°

C

TO DEMOLISH

EXISTING DOOR TO REMAIN

EXISTING DOOR TO DEMOLISH

NEW DOOR

SMOKE RATED WALL

NEW LIGHTS (SEE ELECTRICAL DETAILS)

KEY AREA SHOWN

PROJECT

NORTH

T2-S1

T2-S2

T2-SA

T2-B

FOOTPRINT OF NEW

CONSTRUCTION.

PREPARE AREA FOR

NEW CONSTRUCTION.

FOOTPRINT OF NEW

CONSTRUCTION. SEAL WINDOW DURING

CONSTRUCTION

SEAL WINDOW DURING

CONSTRUCTION

TEMPORARY LOCATION OF EXHAUST.

MOVE INSIDE NEW TR ONCE FEASIBLE.

T2-SB

ANTE

ROOM

T2-S1

T2-SA

T2-B

LINE OF NEW

CONSTRUCTION

LINE OF NEW

CONSTRUCTION.

T2-SB

T2-S1

T2-S2

T2-SA

T2-B

01WA-103c

01WA-103c

01WA-103b

01WA-103b

01WA-103b

161 SF

TR TOWER 2

T2-02

10' - 10 1/2" CLEARANCE

DATA RACK

ELEC PANEL

E1C

E1C

E1C

IN-03.01-10

EXAM 1

2C128

117 SF

EXAM 3

2C132

107 SF

EXISTING

FLOORINGN

E W

O R

IN

G

T2-SB

T2-A

T2-1

T2-2

ELECT PANEL

EXPANSION

JOINT

12' - 2 3/8"

3' - 6"

7' - 9"

5 1/2"

5 7/8"

/4

6"

1/

2"

7/ 8"

1/

2"

6"

T2-02

PHARMACY

2C131

83 SF

C3

2A101c

1225 SF

IN-01.02

04a

02b

T2-S1

T2-S2

T2-SA

T2-B

01WA-103c

01WA-103c

161 SF

TR TOWER 2

T2-02

EXPOSED

EXAM 1

2C128

117 SF

PHARMACY

2C131

83 SF

EXAM 3

2C132

107 SF

T2-SB

T2-A

T2-1

T2-2

C3

2A101c

1225 SF

1' - 11"

2'

7"

2' - 0"

2'

7"

2'

6" 2' - 0"

AC UNIT

1' - 2"

TR TOWER 2

01W

0223R 01S

01A 01

EXAM 3

2C132

107 SF

EXAM 1

2C128

117 SF

C3

2A101c

1225 SF

PHARMACY

2C131

83 SF

EXAM 3

2C132

107 SF

EXAM 1

2C128

117 SF

C3

2A101c

1225 SF

PHARMACY

2C131

83 SF

NFPA

TABLE 7.2.1.1 FIRE RESISTANCE RATING FOR TYPE I - 332 (HR)

COLUMNS

SUPPORTING MORE THAN ONE FLOOR 3 HOUR

SUPPORTING ONE FLOOR / ROOF ONLY 2 HOUR

BEAMS

SUPPORTING ONE FLOOR / ROOF ONLY 2 HOUR

FLOOR/CEILING ASSEMBLIES 2 HOUR

ROOF/CEILING ASSEMBLIES 1 1/2 HOUR

INTERIOR/EXTERIOR NONBEARING WALLS 0 HOUR

FIRE RATED REQUIREMENTS

FIRE RATING SCHEDULE

UL

REFERENCE

COLUMNS SUPPORTING ONE FLOOR

HOURLY

RATINGTYPE ELEMENT

I 2 HR UL X854

I COLUMNS SUPPORTING MORE

THAN ONE FLOOR

3 HR UL X854

COLUMNS SUPPORTING ROOFI 2 HR UL X854

FLOOR DECKSI 2 HR UL D779

FLOOR SUPPORTSI 2 HR UL P732

ROOF DECKSI 1 1/2 HR UL P732

ROOF SUPPORTSI 2 HR UL N732

FIRE RATED SCHEDULE

+ POSITIVE ( + ) PRESSURE

CONSTRUCTION ZONE (--) PRESSURE

ANTE ROOM ( - ) PRESSURE

TEMPORARY ICRA BARRIER

TEMPORARY ICRA DOOR

CONSTRUCTION TACK MAT

HEPA EQUIPED EXHAUST

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0 /2

:0

:3 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n E

H R

M /B

L D

G

W

T R

T O

W E

R

.r v t

01WA-102

BUILDING 01W - LEVEL 02 - DEMO, FLOOR

PLANS & RCPS

01W

MA SR/RB

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

1. ALL PRODUCTS AND FINISHES SHALL MATCH EXISTING OR

ADJACENT EXISTING UNLESS OTHERWISE NOTED.

2. PATCH AND REPAIR WALLS, FLOORS AND CEILINGS

WHERE MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS

ARE DEMOLISHED.

3. PROTECT FINISHES IN ROOMS ADJACENT TO THE AREA OF

WORK AND PARTS THAT ARE NOT INCLUDED IN THE

SCOPE.

4. CONTRACTOR SHALL LEAVE FIRE RATING STAMP

UNPAINTED AND VISIBLE ON THE NEW INSTALLED FRT

PLYWOOD. SEE DETAIL 5/AE401.

5. REFER TO SHEET AS101 FOR ICRA REQUIREMENTS AND

DETAILS.

6. PATCH AND REPAIR CEILING, WALLS AND FLOORS AS

REQUIRED WHERE ICRA BARRIERS WILL BE CONSTRUCTED

AND REMOVED.

7. REFER TO SHEET A-602 FOR DOOR SCHEDULE.

PROJECT

NORTH

PROJECT

NORTH

PROJECT

NORTH

PROJECT

NORTH

GENERAL NOTES

KEY PLAN

KEY NOTES (THIS SHEET ONLY)

LEGEND

1/4" = 1'-0"

LEVEL 02 - TR TOWER 2 - DEMO FLOOR PLAN

1/4" = 1'-0"

LEVEL 02 - TR TOWER 2 - DEMO RCP

1/4" = 1'-0"

RM T2-02 - FLOOR PLAN

1/4" = 1'-0"

RM T2-02 - RCP

9 INSTALL TEMPORARY 1 HR CONSTRUCTION ICRA BARRIER

TO SEPARATE CONSTRUCTION AREA FROM OCCUPIED

SPACE.

10 INSTALL FIRE RESISTANT TEMPORARY SELF-CLOSING DOOR,

SOLID CORE WOOD IN STEEL FRAME, PAINTED, AT OPENING

AND MATCH RATING OF ICRA BARRIER, TYPICAL.

11 PLACE TACKY MATS AT ENTRANCE AND EXIT OF

CONSTRUCTION AREA, MINIMUM SIZE 24"x36", TYPICAL.

1 DEMOLISH EXISTING WALL. PATCH EXPOSED WALL

INTERSECTIONS TO MATCH EXISTING.

2 DEMOLISH PORTION OF EXISTING WALL. PREPARE FOR NEW

DOOR/FRAME.

3 INSTALL NEW DOOR/FRAME.

4 CONSTRUCT NEW WALL.

5 CONSTRUCT NEW FLOOR.

6 APPLY ANTI-STATIC COATING TO EXPOSED FLOOR. PROVIDE

VINYL REDUCER STRIP AT EXISTING FLOORING TRANSITION.

7 INSTALL NEW RESILIENT RUBBER BASE AT ROOM

PERIMETER WITH SEALANT AT THE BOTTOM.

8 INSTALL FRT PLYWOOD OVER WALLS AS NEEDED PER

DETAIL 3/AE401, TYPICAL.

ICRA KEYNOTES

Revisions: Date:

09/03/20259/3/2025 117 OF 693

ICRA CLASS III

ICRA CLASS IV

ICRA CLASS II

FIRE EXTINGUISHER CABINETFEC

FIRE EXTINGUISHERFE

BUILDING BOUNDARY LINE

2 HR FIRE RATED WALL

1 HR FIRE RATED WALL

SMOKE RATED WALL

1W-5

1W-6

T2-A

T2-2

T2-1

T2-B

613 SF

SURGEONS (13)

3C-179

41 SF

TLT

3C-180

39 SF

TLT

3C-181

315 SF

RESIDENTS (11)

3C-182

76 SF

NURSE NAV

3C-183

99 SF

I.C. MGR / SW

3C-184

267 SF

CONFERENCE

3C185

68 SF

SECY

3C186

665 SF

AA

3C187

85 SF

SURG

3C188

83 SF

H.S.S.

3C189

97 SF

CLIN

3C190

97 SF

CHIEF SURG

3C191

149 SF

3C147B

S F

C O

M

C L

O S

E T

C

-1

100 SF

ELEC

CLOSET

3C-152

8 SF

3C-156A

72 SF

3C-156 265 SF

EXAM 1

3C-155

188 SF

LASER

3C-154

RETINAL

PHOTOGRAPHY

3C-153

108 SF

EXAM 7

3C-150

134 SF

3C151

133 SF

EXAM 5

3C-149

101 SF

EXAM 4

3C-145A

139 SF

EXAM 2

3C-143

175 SF

STAFF

OPTOMIST

3C140

173 SF

CHIEF

OPTOMIST

3C139

92 SF

OPTOMETRIST

3C-141

233 SF

3C138

96 SF

MAN TLT.

3C134

77 SF

WOMAN

3C13590 SF

OFFICE

3C131

42 SF

ELEV.

W1

42 SF

ELEV.

W2

525 SF

C3-26

93 SF

STORAGE

3C142

89 SF

OPTIC NERVE

IMAGING

3C144

88 SF

VISUAL FIELDS

3C146

111 SF

EXAM 3

3C-145

146 SF

EXAM 1

3C148

105 SF

EXAM 6

114 SF

BUS. OFFICE

3C166

105 SF

TUMOR REG

3C165

360 SF

IRM

3C167

997 SF

WAITING ROOM

3C147

S

F

B U

S

O F

F

IC

E

C

407 SF

IRM

3C168A

315 SF

BLIND REHAB

3C169

100 SF

EXAM

3C170

102 SF

EXAM

3C171

183 SF

WAITING AREA

186 SF

3C137

419 SF

OPTICAL

CONFERENCE

3C133

196 SF

OPTICAL STORE

3C132

210 SF

STAIR

135 SF

C3-25

BLDG. 02

BUILDING 01W

PHASE 1:

CONTRACTOR TO COMPLETE THE WORK OF THIS TR AND

ASSOCIATED DATA DROPS. COMPLETE ONE SECTION AT A

TIME AS DIRECTED TO COR.

BUILDING 01W

SECTION 1A:

CONTRACTOR TO COORDINATE WITH VA FOR

ROOM CLOSURES AND AVAILABILITY TO COMPLETE

DATA WIRING IN THIS AREA.

BUILDING 01W

SECTION 1B:

CONTRACTOR TO COORDINATE WITH VA FOR ROOM

CLOSURES AND AVAILABILITY TO COMPLETE DATA

WIRING IN THIS AREA.

BLDG. 01W

BLDG. 01

TR TOWER 2

T2-03

164 SF

94 SF

STAFF

RESIDENT

3C-136

227 SF

STAIRS

FEC

NEW SEMI-RECESSED FEC, TO MATCH

OR EXCEED EXISTING EXTINGUISHER IN ABC RATING AND

SIZE. SEE DET 3/A603.

1W-1

1W-2

1W-3

1W-4

TR TOWER 2

01W

01S

01A 01

23R

KEY AREA SHOWN

PROJECT

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0

/2

:1

:3 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n E

H R

M /B

L D

G

L E

V E

L

.r v t 01WAS103

BUILDING 01W - LEVEL 03 - PHASING PLAN

01W

MA RB

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

PROJECT

NORTH

KEY PLAN

LEGEND

1/16" = 1'-0"

BUILDING 01W - LEVEL 03 - PHASING PLAN

09/03/20259/3/2025 118 OF 693

X

W

TO DEMOLISH

EXISTING DOOR TO REMAIN

EXISTING DOOR TO DEMOLISH

NEW DOOR

SMOKE RATED WALL

NEW LIGHTS (SEE ELECTRICAL DETAILS)

KEY AREA SHOWN

PROJECT

NORTH

T2-S1

T2-S2

T2-SA

T2-B

FOOTPRINT OF NEW

CONSTRUCTION.

PREPARE AREA FOR

NEW CONSTRUCTION.

FOOTPRINT OF NEW

CONSTRUCTION.

SEAL WINDOW DURING

CONSTRUCTION

SEAL WINDOW DURING

CONSTRUCTION

TEMPORARY LOCATION OF EXHAUST.

MOVE INSIDE NEW TR ONCE FEASIBLE.

T2-SB

ANTE

ROOM

3' - 8"

T2-S1

T2-S2

T2-SA

T2-B

LINE OF NEW

CONSTRUCTION

LINE OF NEW

CONSTRUCTION.

T2-SB

T2-S1

T2-S2

T2-SA

T2-B

01WA-103c

01WA-103c

01WA-103b

01WA-103b

01WA-103b

164 SF

TR TOWER 2

T2-03

C

LE

A R

A N

C E

11' - 0 1/2" CLEARANCE

E1C E1C

E1C

IN-03.01-13

CHIEF OPTOMIST

3C139

173 SF

CORR

310 SF

3C138

233 SF

NEW

FLOORING

E X

IS

T

IN

G

O R

IN

G

T2-SB

T2-A

T2-1

T2-2

T2-03

ELECT PANEL

12' - 2 3/8"

5 7/8"

5 1/2"

7' - 9"

3' - 6"

FACE OF

STUDS

/4

6"

1/ 2"

7/ 8"

1/

2" 6"

.0

AE512

IN-01.31

02b

04a

T2-S1

T2-S2

T2-SA

T2-B

01WA-103c

01WA-103c

164 SF

TR TOWER 2

T2-03

CHIEF OPTOMIST

3C139

173 SF

CORR

310 SF

3C138

233 SF

EXPOSED

T2-SB

T2-A

T2-1

T2-2

EXPANSION

JOINT

1' - 7"

1'

3"

2' - 1"

1'

2'

1"

8"

1' - 9"

AC UNIT

1' - 2"

TR TOWER 2

01W

01S

01A 01

23R

CHIEF OPTOMIST

3C139

173 SF

STAFF OPTOMIST

3C140

175 SF

CORR

310 SF

3C138

233 SF

CHIEF OPTOMIST

3C139

173 SF

STAFF OPTOMIST

3C140

175 SF

CORR

310 SF

3C138

233 SF

NFPA

TABLE 7.2.1.1 FIRE RESISTANCE RATING FOR TYPE I - 332 (HR)

COLUMNS

SUPPORTING MORE THAN ONE FLOOR 3 HOUR

SUPPORTING ONE FLOOR / ROOF ONLY 2 HOUR

BEAMS

SUPPORTING ONE FLOOR / ROOF ONLY 2 HOUR

FLOOR/CEILING ASSEMBLIES 2 HOUR

ROOF/CEILING ASSEMBLIES 1 1/2 HOUR

INTERIOR/EXTERIOR NONBEARING WALLS 0 HOUR

FIRE RATED REQUIREMENTS

FIRE RATING SCHEDULE

UL

REFERENCE

COLUMNS SUPPORTING ONE FLOOR

HOURLY

RATINGTYPE ELEMENT

I 2 HR UL X854

I COLUMNS SUPPORTING MORE

THAN ONE FLOOR

3 HR UL X854

COLUMNS SUPPORTING ROOFI 2 HR UL X854

FLOOR DECKSI 2 HR UL D779

FLOOR SUPPORTSI 2 HR UL P732

ROOF DECKSI 1 1/2 HR UL P732

ROOF SUPPORTSI 2 HR UL N732

FIRE RATED SCHEDULE

+ POSITIVE ( + ) PRESSURE

CONSTRUCTION ZONE (--) PRESSURE

ANTE ROOM ( - ) PRESSURE

TEMPORARY ICRA BARRIER

TEMPORARY ICRA DOOR

CONSTRUCTION TACK MAT

HEPA EQUIPED EXHAUST

1. ALL PRODUCTS AND FINISHES SHALL MATCH EXISTING OR

ADJACENT EXISTING UNLESS OTHERWISE NOTED.

2. PATCH AND REPAIR WALLS, FLOORS AND CEILINGS

WHERE MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS

ARE DEMOLISHED.

3. PROTECT FINISHES IN ROOMS ADJACENT TO THE AREA OF

WORK AND PARTS THAT ARE NOT INCLUDED IN THE

SCOPE.

4. CONTRACTOR SHALL LEAVE FIRE RATING STAMP

UNPAINTED AND VISIBLE ON THE NEW INSTALLED FRT

PLYWOOD. SEE DETAIL 5/AE401.

5. REFER TO SHEET AS101 FOR ICRA REQUIREMENTS AND

DETAILS.

6. PATCH AND REPAIR CEILING, WALLS AND FLOORS AS

REQUIRED WHERE ICRA BARRIERS WILL BE CONSTRUCTED

AND REMOVED.

7. REFER TO SHEET A-602 FOR DOOR SCHEDULE.

PROJECT

NORTH

PROJECT

NORTH

PROJECT

NORTH

PROJECT

NORTH

GENERAL NOTES

KEY PLAN

KEY NOTES (THIS SHEET ONLY)

LEGEND

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0 /2

:0

:4 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n E

H R

M /B

L D

G

W

T R

T O

W E

R

.r v t

01WA-103

BUILDING 01W - LEVEL 03 - DEMO, FLOOR

PLANS & RCPS

01W

MA SR/RB

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

1/4" = 1'-0"

LEVEL 03 - TR TOWER 2 - DEMO FLOOR PLAN

1/4" = 1'-0"

LEVEL 03 - TR TOWER 2 - DEMO RCP

1/4" = 1'-0"

RM T2-03 - FLOOR PLAN

1/4" = 1'-0"

RM T2-03 - RCP

9 INSTALL TEMPORARY 1 HR CONSTRUCTION ICRA BARRIER

TO SEPARATE CONSTRUCTION AREA FROM OCCUPIED

SPACE.

10 INSTALL FIRE RESISTANT TEMPORARY SELF-CLOSING DOOR,

SOLID CORE WOOD IN STEEL FRAME, PAINTED, AT OPENING

AND MATCH RATING OF ICRA BARRIER, TYPICAL.

11 PLACE TACKY MATS AT ENTRANCE AND EXIT OF

CONSTRUCTION AREA, MINIMUM SIZE 24"x36", TYPICAL.

1 DEMOLISH EXISTING WALL. PATCH EXPOSED WALL

INTERSECTIONS TO MATCH EXISTING.

2 DEMOLISH PORTION OF EXISTING WALL. PREPARE FOR NEW

DOOR/FRAME.

3 INSTALL NEW DOOR/FRAME.

4 CONSTRUCT NEW WALL.

5 CONSTRUCT NEW FLOOR.

6 APPLY ANTI-STATIC COATING TO EXPOSED FLOOR. PROVIDE

VINYL REDUCER STRIP AT EXISTING FLOORING TRANSITION.

7 INSTALL NEW RESILIENT RUBBER BASE AT ROOM

PERIMETER WITH SEALANT AT THE BOTTOM.

8 INSTALL FRT PLYWOOD OVER WALLS AS NEEDED PER

DETAIL 3/AE401, TYPICAL.

ICRA KEYNOTES

Revisions: Date:

09/03/20259/3/2025 119 OF 693

LEVEL 00G

0' - 0"

LEVEL 01

11' - 9"

LEVEL 03

36' - 6 1/2"

LEVEL 02

24' - 6 1/2"

LEVEL 4

51' - 2 1/2"

01WA-103c

PARAPET TRIM

VENEER BRICK

HORIZONTAL SLIP

JOINT, TYPICAL

WALL TO WALL

EXPANSION JOINT

COVER

0"

2'

LEVEL 00G

0' - 0"

LEVEL 01

11' - 9"

LEVEL 03

36' - 6 1/2"

LEVEL 02

24' - 6 1/2"

LEVEL 4

51' - 2 1/2"

T2-S1 T2-S2

PARAPET TRIM

VENEER BRICK

HORIZONTAL SLIP

JOINT, TYPICAL

EXISTING LIMESTONE

EXISTING ALUMINUM FIXED

WINDOW

EXISTING VENEER

BRICK

LEVEL 00G

0' - 0"

LEVEL 01

11' - 9"

LEVEL 03

36' - 6 1/2"

LEVEL 02

24' - 6 1/2"

LEVEL 4

51' - 2 1/2"

01WA-103c

PARAPET TRIM

VENEER BRICK

HORIZONTAL SLIP

JOINT, TYPICAL

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0 /2

:0

:4 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n E

H R

M /B

L D

G

W

T R

T O

W E

R

.r v t

01WA-103b

TR TOWER 2 - EXTERIOR ELEVATIONS

01W

MA SR

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

1/4" = 1'-0"

TR TOWER 2 NORTHEAST ELEVATION

1/4" = 1'-0"

TR TOWER 2 NORTHWEST ELEVATION

1/4" = 1'-0"

TR TOWER 2 SOUTHWEST ELEVATION

09/03/20259/3/2025 120 OF 693

LEVEL 01

11' - 9"

LEVEL 03

36' - 6 1/2"

LEVEL 02

24' - 6 1/2"

LEVEL 4

51' - 2 1/2"

LEVEL 01

11' - 9"

LEVEL 2

24' - 6 1/2"

LEVEL 03

36' - 6 1/2"

LEVEL 02

24' - 6 1/2"

2F ROOF

36' - 6 1/2"

LEVEL 03

36' - 6 1/2"

LEVEL 03

36' - 6 1/2"

LEVEL 4

51' - 2 1/2"

01WA-103c

164 SF

TR TOWER 2

T2-00G

160 SF

TR TOWER 2

T2-01

CORRIDOR

1280 SF

PHARMACY

2C131

83 SF

CORR

310 SF

EXTERIOR WALL:

• BRICK VENEER

• 2 3/16" AIR SPACE W/ 2"

ALUMINUM T- FURRING

• R-10ci RIGID INSULATION

• AIR & WATER resistance BARRIER

• 5/8" EXTERIOR GYPSUM BOARD

• 8" METAL STUDS @ 16" OC

• R-15 BATT INSULATION

• VAPOR RETARDER

• 5/8" TYPE X GYPSUM BOARD

161 SF

TR TOWER 2

T2-02

164 SF

TR TOWER 2

T2-03

01W-AE451

01W-AE451

Level 00G 0' - 0"

Level 01 11' - 9"

Level 02 24' - 6 1/2"

Level 03 36' - 6 1/2"

Level 04 51' - 2 1/2"

Level 00B -13' - 9"

TOW DATA

CENTER

18' - 0"

TOF

-4' - 0"

EXAM

1C131

191 SF

2'

LEVEL 00G

0' - 0"

LEVEL 01

11' - 9"

LEVEL 03

36' - 6 1/2"

LEVEL 02

24' - 6 1/2"

LEVEL 4

51' - 2 1/2"

T2-2T2-1

LEVEL 01

11' - 9"

LEVEL 2

24' - 6 1/2"

LEVEL 03

36' - 6 1/2"

LEVEL 02

24' - 6 1/2"

2F ROOF

36' - 6 1/2"

LEVEL 03

36' - 6 1/2"

LEVEL 03

36' - 6 1/2"

LEVEL 4

51' - 2 1/2"

01WA-103c

164 SF

TR TOWER 2

T2-00G

160 SF

TR TOWER 2

T2-01

164 SF

TR TOWER 2

T2-03

161 SF

TR TOWER 2

T2-02

R1

E1C

F2

E1C

F-1

F2

F1

EXTERIOR WALL:

• BRICK VENEER

• 2 3/16" AIR SPACE W/ 2"

ALUMINUM T- FURRING

• R-10ci RIGID INSULATION

• AIR & WATER resistance

BARRIER

• 5/8" EXTERIOR GYPSUM

BOARD

• 8" METAL STUDS @ 16"

OC

• R-15 BATT INSULATION

• VAPOR RETARDER

• 5/8" TYPE X GYPSUM

BOARD

Level 00G 0' - 0"

Level 01 11' - 9"

Level 02 24' - 6 1/2"

Level 03 36' - 6 1/2"

Level 04 51' - 2 1/2"

TOW DATA

CENTER

18' - 0"

TOF

-4' - 0"

A F

G

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0 /2

:0

:3 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n E

H R

M /B

L D

G

W

T R

T O

W E

R

.r v t

01WA-103c

TR TOWER 2 - BUILDING SECTIONS

01W

MA SR

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

1/4" = 1'-0"

TR TOWER 2 SECTION NORTH/SOUTH LOOKING EAST

1/4" = 1'-0"

TR TOWER 2 SECTION EAST/WEST LOOKING NORTH

(E) LIMESTONE

PARAPET

(E) BRICK VENEER

09/03/20259/3/2025 121 OF 693

LEVEL 01

11' - 9"

LEVEL 03

36' - 6 1/2"

LEVEL 4

51' - 2 1/2"

EXTERIOR WALL:

• BRICK VENEER

• 2 3/16" AIR SPACE W/ 2"

ALUMINUM T- FURRING

• R-10ci RIGID INSULATION

• AIR & WATER resistance BARRIER

• 5/8" EXTERIOR GYPSUM BOARD

• 8" METAL STUDS @ 16" OC

• R-15 BATT INSULATION

• VAPOR RETARDER

• 5/8" TYPE X GYPSUM BOARD

R1

F2

01W-AE511

01W-AE511

01W-AE511

LEVEL 00G

0' - 0"

LEVEL 01

11' - 9"

LEVEL 03

36' - 6 1/2"

LEVEL 4

51' - 2 1/2"

01W-AE511

MBF2H0350

FIRE STOPPING, TYP

SPRAY FIRE PROOFING AT

ALL STRUCTURAL STEEL

2HBCP-2-250

MILL FINISH ALUMINUM FLOOR

EXPANSION JOINT COVER

2 HOUR RATED WITH

MBF2H0350

UL LISTING FF-D-1071

50% MOVEMENT

TYPICAL AT EXISTING FLOOR

CONNECTIONF2

01W-AE511

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0 /2

:0

:2 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n E

H R

M /B

L D

G

W

T R

T O

W E

R

.r v t

01W-AE451

WALL SECTIONS

01W

MA SR

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

1/2" = 1'-0"

TR TOWER T2 NORTH WALL SECTION

1/2" = 1'-0"

TR TOWER T2 SOUTH WALL SECTION

09/03/20259/3/2025 122 OF 693

T2-S1

T2-S2

T2-SA

T2-B

LINE OF NEW ROOF

T2-S1

T2-S2

T2-SA

T2-B

01WA-103c

01WA-103c

01WA-103b

01WA-103b

01WA-103b

T2-SB

T2-A

T2-1

T2-2

1/4" / 1'-0"

1/4" / 1'-0"

" / 1'-0"

R1

THRU-WALL SCUPPER

RE: 3/01S-A-513 (SIM)

(E) MEMBRANE ROOFING

SYSTEM

1/ 4"

'-0

MECH SHAFT

1" / 1'-0"

TO DEMOLISH

EXISTING DOOR TO REMAIN

EXISTING DOOR TO DEMOLISH

NEW DOOR

SMOKE RATED WALL

NEW LIGHTS (SEE ELECTRICAL DETAILS)

KEY AREA SHOWN

PROJECT

NORTH

TR TOWER 2

01W

01S

01A 01

01W

01S

01A 01

23R

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0 /2

:0

:3 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n E

H R

M /B

L D

G

W

T R

T O

W E

R

.r v t

01WA-104

BUILDING 01W - ROOF PLAN

01W

MA RB/SR

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

1/4" = 1'-0"

TR TOWER 2 - ROOF PLAN (EXISTING)

1/4" = 1'-0"

TR TOWER 2 - ROOF PLAN

PROJECT

NORTH

PROJECT

NORTH

1. ALL PRODUCTS AND FINISHES SHALL MATCH EXISTING OR

ADJACENT EXISTING UNLESS OTHERWISE NOTED.

2. PATCH AND REPAIR WALLS, FLOORS AND CEILINGS

WHERE MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS

ARE DEMOLISHED.

3. PROTECT FINISHES IN ROOMS ADJACENT TO THE AREA OF

WORK AND PARTS THAT ARE NOT INCLUDED IN THE

SCOPE.

4. CONTRACTOR SHALL LEAVE FIRE RATING STAMP

UNPAINTED AND VISIBLE ON THE NEW INSTALLED FRT

PLYWOOD. SEE DETAIL 5/AE421.

5. REFER TO SHEET AS101 FOR ICRA REQUIREMENTS AND

DETAILS.

6. PATCH AND REPAIR CEILING, WALLS AND FLOORS AS

REQUIRED WHERE ICRA BARRIERS WILL BE CONSTRUCTED

AND REMOVED.

1 CONSTRUCT NEW ROOF.

GENERAL NOTES

KEY PLAN

KEY NOTES (THIS SHEET ONLY)

LEGEND

09/03/20259/3/2025 123 OF 693

EXTRUDED ALUMINUM

"T" PROFILE

ALUMINUM BRACKET @ 32" OC

STAINLESS STEEL HEX HEAD

SELF DRILLING SCREWS

CORIUM VENEER BRICK

SYSTEM

ALUMINUM BASE

FLASHING WITH

HEMMED EDGE OVER

R-GUARD FASTFLASH

PERFORATED ANGLE

1/2" SEALANT & BACKER

ROD

BACKER ROD &

SEALANT IN JOINT

SLOPE TO DRAIN

EPDM OR FOAMED

POLYETHYLENE SILL

SEALER

1/

4"ALUMINUM BASE FLASHING

M

IN

7/8"

R-10 RIGID INSULATION

CONT AIR &

WATER resistance

BARRIER

1/2" PLYWOOD SHEATHING

R-13 BATT INSULATION

CONT VAPOR RETARDER

5/8" GWB

1/2" FIRE TREATED

PLYWOOD SHEATHING

REINF CONC FLOOR

PER STRUCT

FLOOR FINISH AND

BASE PER FINISH

SCHEDULE, TYP

AIR & WATER resistance

BARRIER OVER BASE

FLASHING

FILL EXPANSION JOINT

WITH JOINT FILLER

WATER PROOFING

R-10 RIGID INSULATION

VAPOR BARRIER

3/4"x3/4" GALV

SHEET METAL TRIM

LEVEL 01

11' - 9"

AIR & WATER

RESISTANCE BARRIER

CONT Z-CHANNEL

FAST FLASH OVER

FLOOR JOINT

ALUMINUM BRACKET @

32" OC

STAINLESS STEEL HEX

HEAD SELF DRILLING

SCREWS

R-10 RIGID INSULATION

EXTRUDED ALUMINUM T-

PROFILE GRADE 6063T6

MILL FINISH

BACKER ROD &

SEALANT IN JOINT

EPDM OR FOAMED

POLYETHYLENE SILL

SEALER

R-13 BATT INSULATION

CONT VAPOR RETARDER 5/8" GWB

1/2" FIRE TREATED

PLYWOOD SHEATHING

CONCRETE TOPPING

OVER METAL DECK

PER STRUCT

FLOOR FINISH AND

BASE PER FINISH

SCHEDULE, TYP

SPRAY APPLIED

FIREPROOFING

FILL GAP WITH MINERAL

WOOL INSULATION

REFER TO STRUCTURAL

DETAIL

3/4"x3/4" GALV

SHEET METAL TRIM

FILL GAP WITH MINERAL

WOOL INSULATION

LEVEL 4

51' - 2 1/2"

1/2" COVER BOARD

TREATED WOOD NAILERS TO

MATCH HEIGHT OF INSULATION

AND COVER BOARD

FLASHING MEMBRANE

HOT-AIR WELD

ROOFING MEMBRANE

R-30ci RIGID INSULATION, MIN

PRE-FINISHED SHEET METAL

PARAPET CAP FLASHING

WITH WATERTIGHT JOINT

ROOF FLASHING

MEMBRANE WRAP OVER

TOP OF PARAPET WALL

VAPOR RETARDER

AIR & WATER

RESISTANCE BARRIER

CONT Z-CHANNEL

FAST FLASH OVER

FLOOR JOINT

ALUMINUM BRACKET @

32" OC

STAINLESS STEEL HEX

HEAD SELF DRILLING

SCREWS

VENTILATION GAP

PROTECTED WITH

INSECT MESH

3/

4"

3/

4"

2" 1/2" 8"

R-10 RIGID

INSULATION

EXTRUDED ALUMINUM

T-PROFILE GRADE

6063T6 MILL FINISH

CORIUM BRICK

CORIUM BRICK TRAY

SAND LAME / POLYMER

CEMENT POINTING

MORTAR

/2

3/4"

1/4"

LEVEL 4

51' - 2 1/2"

SURFACE MOUNTED CONT

REGLET

CONT BEAD OF SEALANT

EXISTING REINF CONC

ROOF PARAPET

EXISTING BUILDINGNEW ADDITION

/4

FIRE RETARDANT SPRAY FOAM

OVER STRUCTURAL STEEL

MEMBERS

SARNAFIL FLASHING

MEMBRANE, HOT-AIR WELD

NEW OPENING IN

EXISTING PRECAST

CONC PARAPET FOR

INSTALLATION OF NEW

SCUPPER

O P

N G

"x

INSTALL THRU-WALL

SCUPPER IN FULL BED

OF SEALANT

FLASHING MEMBRANE

HOT-AIR WELD

ROOFING MEMBRANE

O P

N G

5/

8" x

5"

LEVEL 00G

0' - 0"

2" 5/

8"

1 15/16" 5" 1 15/16"

1 HR FIRE RATED HM

DOOR AND FRAME,

TYP

PROVIDE NEW LOOSE

LINTEL AT NEW DOOR

OPENING, TYP

5/8" GWB OVER (E) STUDS @

AREA ABOVE NEW DOOR

OPENING

5/8" GWB OVER 2 1/2" STUDS

@ 16" OC ABOVE NEW DOOR

OPENING

PATCH AND REPAIR (E)

CEILING

SEALANT, TYP

CONCRETE PATCH

AND FILL @ (E) FLOOR

EDGE

EXISTING BUILDINGNEW ADDITION

BCSW PRE-

COMPRESSED

PRIMARY SEAL

5/8" GWB

1/2" FIRE TREATED

PLYWOOD SHEATHING

3/4"x3/4" GALV

SHEET METAL TRIM

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0 /2

:0

:3 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n E

H R

M /B

L D

G

W

T R

T O

W E

R

.r v t

01W-AE511

EXTERIOR DETAILS

01W

MA SR

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

3" = 1'-0"

TYPICAL DETAIL AT WALL BASE

3" = 1'-0"

TYPICAL DETAIL - FLOOR

3" = 1'-0"

TYPICAL PARAPET DETAIL

3" = 1'-0"

SECTION DETAIL - THRU-WALL SCUPPER

3" = 1'-0"

TYPICAL DETAIL - NEW DOOR HEAD AND SILL

09/03/20259/3/2025 124 OF 693

ICRA CLASS III

ICRA CLASS IV

FIRE EXTINGUISHER CABINETFEC

FIRE EXTINGUISHERFE

ICRA CLASS II

BUILDING BOUNDARY LINE

2 HR FIRE RATED WALL

1 HR FIRE RATED WALL

SHOWN AREA

PROJECT

NORTH

A7 A6

A5 A4

A3

A8

A11 A10

A9

A2 A1

164 SF

ELEC

BD102 331 SF

ELECTRIC

BD103

109 SF

STORAGE

BD107

167 SF

WATER INTAKE

BD108

497 SF

WATER

SOFTENER

BD106

86 SF

BD105

1206 SF

BIOMEDICAL

ENGINEERING

BD104

238 SF

BD100

718 SF

MAS MAIL ROOM

BD101

1074 SF

CORRIDOR

71 SF

ELEC

104 SF

SHREDDING

MAS

27 SF

STOR

19 SF

TLT

49 SF

ELEV

F8

775 SF

ENG. PLUMPING

SHOP

BD112

1061 SF

ENG. AIR

CONDITIONING

SHOP

BD110

238 SF

HOT WATER

HEATERS

ENG STORAGE

BD106A

809 SF

ENG.

ELECTRICAL

SHOP

72 SF

HVAC

BD104A

169 SF

LOCKSMITH

BD104B

501 SF

ENG. M&R

FOREMAN

1444 SF

CARPENTRY

SHOP

183 SF

M&O FOREMAN

BD102C

116 SF

PAINT

VAULT

87 SF

STORAGE

BD102D

108 SF

PAINT

BOOTH

BD102B

85 SF

TOILET

BD102A

55 SF

TLT

382 SF

PAINT SHOP

BUILDING 02

PHASE 1:

CONTRACTOR TO COMPLETE THE WORK OF THIS TR

AND ASSOCIATED DATA DROPS. COMPLETE ONE

SECTION AT A TIME AS DIRECTED TO COR.

BUILDING 02

SECTION 1A:

CONTRACTOR TO COORDINATE WITH VA FOR ROOM

CLOSURES AND AVAILABILITY TO COMPLETE DATA

WIRING IN THIS AREA.

BUILDING 02

SECTION 1B:

CONTRACTOR TO COORDINATE WITH VA FOR ROOM

CLOSURES AND AVAILABILITY TO COMPLETE DATA

WIRING IN THIS AREA.

BLDG. 01S

TR TOWER 3

T3-00B

175 SFFEC

NEW SEMI-RECESSED FEC, TO MATCH

OR EXCEED EXISTING EXTINGUISHER IN

ABC RATING AND SIZE. SEE DET 4/A-604.

01W

0223R 01S

TR TOWER 3

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

Office of

Construction and Facilities

Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

ENGINEERING DISCIPLINE:

SPEES DESIGN BUILD

23830 PACIFIC HIGHWAY S. SUITE 300

KENT, WA 98032

/0

/2

:0

:5 a m

B

IM

/5

-2

-7

V A

H u n t i n g to n E

H R

M /B

L D

G

B A

S E

M E

N T

.r v t

02AS100B

BUILDING 02 - LEVEL 00B - PHASING PLAN

MA RB

100% CONSTRUCTION

DOCUMENTS

09/03/2025

581-22-700EHRM INFRASTRUCTURE

UPGRADES - HUNTINGTON

VA HUNTINGTON

1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300

KEY PLAN

LEGEND

1/16" = 1'-0"

BUILDING 02 - LEVEL 00B - PHASING PLAN

PROJECT

NORTH

09/03/20259/3/2025 125 OF 693

File details come from the government source that posted it. Updated .