S02 - ATT 5 - 581-22-700 - 100 Drawings Part-3 of 24.pdf
PDF 18 MB Posted
- Solicitation number
- 36C77626R0025
About this file
This is a 100% Construction Documents set of architectural drawings for EHRM Infrastructure Upgrades at VA Huntington Medical Center, located at 1540 Spring Valley Drive, Huntington, West Virginia. The project includes construction of two new Tower structures (TR Tower 1 and TR Tower 4) within Building 01S, with phasing plans spanning multiple levels (00G through 06) and associated demolition, floor plans, reflected ceiling plans, exterior elevations, building sections, wall sections, and detailed roof specifications.
The project requires comprehensive construction services including new structural towers with brick veneer exterior walls, interior buildout with fire-rated walls and expansion joints, new roof systems with TPO membrane, mechanical/electrical/plumbing installations, data center construction, fire extinguisher cabinets, and extensive interior finishing. Key technical requirements include 2-hour and 1-hour fire-rated walls, spray-applied fireproofing on structural members, anti-static flooring coatings, polyethylene sheeting for ICRA (Infection Control Risk Assessment) containment barriers during construction, and coordination with existing VA operations across multiple phased sections. The contractor must complete work one section at a time as directed by the Contracting Officer, coordinate room closures and building access with VA, maintain passage access and patient access throughout construction, and comply with all fire-rating schedules and UL listings specified in the detailed construction documents dated September 3, 2025.
View the file
Other files
Show 40 more
Latest 50 of 68 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TR
ICRA PHASING LINE
ICRA CLASS III
ICRA CLASS IV
ICRA CLASS II
FIRE EXTINGUISHER CABINETFEC
FIRE EXTINGUISHERFE
BUILDING BOUNDARY LINE
2 HR FIRE RATED WALL
1 HR FIRE RATED WALL
SMOKE RATED WALL
A B D E F H I J K L MGC N O P Q R S T U V W X Y Z
A16 A15 A14
MARSHALL CAMPUS
BUILDING 01 & 01S
PHASE 1:
CONTRACTOR TO COMPLETE THE WORK OF THIS TR
AND ASSOCIATED DATA DROPS. COMPLETE ONE
SECTION AT A TIME AS DIRECTED TO COR.
BUILDING 01S
PHASE 2:
CONTRACTOR TO COMPLETE THE WORK OF THIS TR
AND ASSOCIATED DATA DROPS. COMPLETE ONE
SECTION AT A TIME AS DIRECTED TO COR.
BUILDING 01S & 12
SECTION 2A:
CONTRACTOR TO COORDINATE WITH VA FOR ROOM
CLOSURES AND AVAILABILITY TO COMPLETE DATA
WIRING IN THIS AREA.
BUILDING 12
SECTION 2B:
CONTRACTOR TO COORDINATE WITH VA FOR ROOM
CLOSURES AND AVAILABILITY TO COMPLETE DATA
WIRING IN THIS AREA.
BUILDING 23R & 23
SECTION 2C:
CONTRACTOR TO COORDINATE WITH VA FOR ROOM
CLOSURES AND AVAILABILITY TO COMPLETE DATA
WIRING IN THIS AREA.
BUILDING 01 & 01S
SECTION 1A:
CONTRACTOR TO COORDINATE WITH VA FOR
ROOM CLOSURES AND AVAILABILITY TO COMPLETE
DATA WIRING IN THIS AREA.
BUILDING 01A & 01S
SECTION 1B:
CONTRACTOR TO COORDINATE WITH VA FOR ROOM
CLOSURES AND AVAILABILITY TO COMPLETE DATA
WIRING IN THIS AREA.
BUILDING 01S
SECTION 1D:
CONTRACTOR TO COORDINATE WITH VA FOR ROOM
CLOSURES AND AVAILABILITY TO COMPLETE DATA
WIRING IN THIS AREA.
BUILDING 01
SECTION 1C:
CONTRACTOR TO COORDINATE WITH VA FOR
ROOM CLOSURES AND AVAILABILITY TO COMPLETE
DATA WIRING IN THIS AREA.
BLDG. 02
BLDG. 01
BLDG. 01A
BLDG. 01S
BLDG. 12
BLDG. 23
BLDG. 23R
BLDG. 01W
FEC
FEC
NEW SEMI-RECESSED FEC, TO MATCH
OR EXCEED EXISTING EXTINGUISHER IN
ABC RATING AND SIZE. SEE DET 4/A-604.
NEW SEMI-RECESSED FEC, TO MATCH
OR EXCEED EXISTING EXTINGUISHER IN
ABC RATING AND SIZE. SEE DET 4/A-604.
158 SF
ENTRANCE #1
243 SF
TELE
GC118
161 SF
BATTERY
GC119
165 SF
ELECTRICAL 1
123 SF
MECH / FIRE
143 SF
ELECTRICAL 2
GC114a
158 SF
BMS
GC114
1363 SF
DATA CENTER
GC115-1
179 SF
ENTRANCE #2
549 SF
CORRIDOR
92 SF
OXYGEN STOR
GC112
69 SF
ELEV.
E-6
69 SF
ELEV.
E-5
436 SF
IRM MECH.
SUPPORT
GC103
52 SF
ELEC
GC111
163 SF
GB160
181 SF
WORKMAN'S
COMP. OFFICE
GC175
90 SF
HBPC OFFICE
GC176
88 SF
WAITING
GC175A
135 SF
BILLING OFFICE
GC177
173 SF
BARBER SHOP
GC178
404 SF
VENDING
GC130
372 SF
ESCORT
GC100
25 SF
GC100B
112 SF
LOCKER
GC100A
77 SF
STOR
GC100C
523 SF
DECON
42-101
228 SF
STAIR 11
106108 SF
ELEC/IRM
GC127
59 SF
ELEC
GC125
121 SF
COMPLIANCE
GC12480 SF
COMPLIANCE
GC123
143 SF
ELEC
GC121 231 SF
MECH
GC122
670 SF
STERILE PREP
42-100
145 SF
STERI SVC
42-103
49 SF
COOLER
GC154
313 SF
GC120F
20 SF
ELEC
GC120A
31 SF
STO
GC120B
69 SF
SLIDES
GC120C
20 SF
TLT
GC120D
89 SF
OFFICE
GC120E
482 SF
AUTOPSY
GC120
73 SF
MECH.
42-102
98 SF
MAINT. ELEV
P9
56 SF
CLOSET
21 SF
GC126
164 SF
VOLUNTEER
SPECIALIST
GC101
116 SF
VOLUNTEER
CHIEF
GC102
122 SF
ENROLL. #3
GC104
112 SF
ENROLL. #2
GC105
76 SF
ENROLL. #1
GC106
S
F
O U
T P
A T
IE
N
T
C O
O R
D
G C
13 SF
S
F
P U
B L
IC
E
L E
V
P
84 SF
PUBLIC ELEV.
P2
73 SF
PUBLIC ELEV.
P1
157 SF
STAIR 1
202 SF
LINEN
GB169
39 SF
HAC
GB170
19 SF
GB173
961 SF
PUBLIC LOBBY
CG19
33 SF
TELE.
GB171
70 SF
ELEC.
GB172
94 SF
SERVICE ELEV.
S1
S
F
S E
R V
IC
E
E L
E V
S
294 SF
SERVICE LOBBY
CG17
75 SF
GB168g114 SF
BVA
GB168c
108 SF
IRM
GB168a
121 SF
EXAM
GB168k
124 SF
FEE CLAIMS
GB168b
95 SF
BOOTH
146 SF
EXAMINER
GB168j
108 SF
GB168l
90 SF
GB168
111 SF
GB168i
188 SF
GB168h
2203 SF
MEDICAL
RECORDS
GB168d
33 SF
GB168f
168 SF
STAIR 4
1415 SF
MECH RM
GB167
188 SF
HEALTH TECH
GB149c
111 SF
HEALTH TECH
GB149d
113 SF
EXAM
GB149e
113 SF
EXAM
GB149f
113 SF
EXAM
GB149g
349 SF
AUDIOLOGY
ROOM
GB149
173 SF
RECEP
GB148
130 SF
OFFICE
GB148a
222 SF
OFFICE
GB148b
147 SF
OFFICE
GB146
38 SF
TLT
GB145
131 SF
CERUMEN
MGMT
GB147b
94 SF
GB143
110 SF
GERI PACT
GB151
86 SF
GERI PACT
GB152106 SF
GB14086 SF
GB141
41 SF
STORAGE
GB141a
80 SF
CLEAN SUPPLY
GB139
S F
P A
L L
C A
R E
G B
98 SF
PALL CARE
GB137
98 SF
GERI PACT
GB153
94 SF
GERI PACT
GB154
95 SF
EXAM 8
GB136
86 SF
PHARM
GB135
245 SF
AMCARE ADMIN
GB150
74 SF
AMCARE
GB150A
115 SF
AMCARE ADMIN
GB168rr
339 SF
GERI PACT
GB155H
643 SF
CORRIDOR
CG11
488 SF
CORRIDOR
CG10
88 SF
EXAM 7
GB134
97 SF
EXAM 6
GB133
97 SF
WALK IN CLINIC
GB156
98 SF
EXAM 15
98 SF
EXAM 4
GB132
108 SF
LOUNGE
GB129
107 SF
WALK IN CLINIC
GB158
95 SF
GB127
104 SF
GB130
86 SF
EXAM 5
GB131
696 SF
CORRIDOR
CG16
115 SF
AMCARE ADMIN
GB155b
106 SF
AMCARE
GB155G
116 SF
EXAM 5
GB155F
69 SF
VAPD
GB155c
97 SF
VAPD
GB165
154 SF
AMCARE ADMIN
CG24
97 SF
VAPD
GB164
465 SF
GB159
158 SF
GB161
148 SF
STAIR 8
63 SF
STAFF TLT
GB119B
91 SF
ELEC.
GB126
144 SF
CASHIER
GA100
198 SF
SMOK. SHLTR
S100
129 SF
STORAGE
GB101C93 SF
VAPD HOLDING
GB101D
53 SF
STOR
144 SF
VAPD CHIEF
GB176A
138 SF
VAPD SECY
GB176
209 SF
VAPD
GB177 1
S
F
V A
P D
W E
A P
O N
G B
A
153 SF
CHIEF DENTAL
GA112
159 SF
CONF.
GA110
639 SF
RECEIVING
ENTRY
120 SF
EXAMINER
GB149h
106 SF
EXAMINER
GB149i
95 SF
BOOTH
95 SF
BOOTH
95 SF
BOOTH
35 SF
TEL
GB166a
111 SF
EXAMINER
GB149j
206 SF
POSTIOGRAPHY
& LAB
GA121
1676 SF
CORRIDOR
CG14
329 SF
CORRIDOR
CG15
196 SF
STAIR 3
GC160
2073 SF
MECH
GB166
85 SF
ELEVATOR
EQUIP.
G01
39 SF
LIFT EQUIP.
G06
122 SF
CORRIDOR
G07
145 SF
LOBBY
G05
CORRIDOR
C-G1
153 SF
ELEC.
G03
138 SF
STAIR
S-1
90 SF
ELEVATOR
SE-1
3136 SF
OPEN
MECHANICAL
SPACE
GO7
3318 SF
MECH.
G02
164 SF
COFFEE
GC161
224 SF
VEST
42-104
64 SF
ELEVATOR
P-2
61 SF
P-1
199 SF
GC162
204 SF
STAIR
S-2
285 SF
VAPD LOCKER
GA101
401 SF
DENTAL ADMIN
GA11189 SF
LOCKER
GC163
146 SF
MECH
GC166
119 SF
MEN
GC168
121 SF
WOMEN
GA10430 SF
COM
GA105
166 SF
WAITING
GC172
246 SF
CORRIDOR
GC179
498 SF
RECEIVING
AREA
GA108
431 SF
BREAKROOM
GA107
293 SF
RECEIVING
ENTRY
GC180
251 SF
STORAGE
GC181
996 SF
PHARMACY
GA106G
152 SF
OFFICE
GA106E
67 SF
GA106H
1835 SF
PHARMACY
GC183
115 SF
TTT
235 SF
LAB
GC184
57 SF
X-RAY
GC185
162 SF
STAIR 6
GC186
1049 SF
CORRIDOR
GC187
188 SF
STAIR 7
S-7
1085 SF
PHARMACY
WAITING
GC188
155 SF
CHAIR 5
GC189
136 SF
CHAIR 6
GC190
140 SF
CHAIR 7
GC191
154 SF
CHAIR 8
GC192
138 SF
RECEPTIONIST
GC193
161 SF
CHAIR 1
GC194
168 SF
CHAIR 2
GC195
166 SF
CHAIR 3
GC196
192 SF
CHAIR 4
GC197
694 SF
CORRIDOR
GC198
82 SF
BATH
GB120A
61 SF
NOUR
GB121
238 SF
BREAK ROOM
GB116
132 SF
EQUIP.
GB115
701 SF
CORR
CG-50
52 SF
ALCOVE
CG-50B
43 SF
SOILED
T3-00Q
114 SF
MENTAL
HEALTH EXAM
CB-114
129 SF
MENTAL
HEALTH EXAM
CB-113
71 SF
VEST.
CG-53
87 SF
ANTE
GB112A
107 SF
TOILET/SHWR
GB112B
135 SF
ISOLATION
CB-112
87 SF
OFFICE
CB-110
74 SF
OFFICE
CB-109
71 SF
CONSULT
CB-108 184 SF
VEST
GB100
311 SF
CORR
CG-52
160 SF
EXAM
CB-106
135 SF
RESULTS
CB-107
419 SF
CORR
CG-51
480 SF
NURSE STATION
CB-105
88 SF
POLICE/VOL
GB101E
146 SF
TRIAGE
CG-54
52 SF
TLT
GB104B
53 SF
TLT
GB104A
105 SF
ANTE
T3-00X
148 SF
ISOLATION
T3-00S
69 SF
TOILET/SHWR
GB120B
62 SF
HAC
GB125B
144 SF
EXAM
GC199
143 SF
EXAM
GB122
139 SF
ALCOVE
766 SF
CORR
CG-49
238 SF
BARI. EXAM
GB124 107 SF
TELECOM
GB125A
144 SF
EXAM
GB123
75 SF
ALCOVE
CG-50A
2416 SF
WAITING
GB102A
146 SF
WOMEN
GC109
173 SF
MEN
GC108
207 SF
STAIR 9
1906 SF
CORRIDOR
TR TOWER 1
T1-00G
169 SF
TR TOWER 4
T4-00G
166 SF
24 SF
CLOSET 1
TR TOWER 1
TR TOWER 4
01W
0223R 01S
01A
NEW DATA CENTER
SHOWN AREA
PROJECT
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/0
/2
:5
:3 a m
B
IM
/5
-2
-7
V A
H u n t i n g to n E
H R
M /B
L D
G
G R
O U
N D
F L O
O R
.r v t
01SAS100G
BUILDING 01S - LEVEL 00G - PHASING PLAN
01S
MA RB
100% CONSTRUCTION
DOCUMENTS
09/03/2025
581-22-700EHRM INFRASTRUCTURE
UPGRADES - HUNTINGTON
VA HUNTINGTON
1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300
KEY PLAN
LEGEND
1" = 20'-0"
BUILDING 01S - LEVEL 00G - PHASING PLAN
PROJECT
NORTH
Revisions: Date:
09/03/20259/3/2025 080 OF 693
C
360°
C
360°
C
W
X
360°
PP
TO DEMOLISH
EXISTING DOOR TO REMAIN
EXISTING DOOR TO DEMOLISH
NEW DOOR
1 HR FIRE RATED WALL
SMOKE RATED WALL
NEW LIGHTS (SEE ELECTRICAL DETAILS)
2 HR FIRE RATED WALL
MOTION DETECTOR
SPRINKLER HEAD
KEY AREA SHOWN
PROJECT
NORTH
X
FOOTPRINT OF NEW
CONSTRUCTION
PREPARE AREA FOR
NEW CONSTRUCTION.
TEMPORARY LOCATION OF EXHAUST.
MOVE INSIDE NEW TR ONCE FEASIBLE.
SEAL DOOR DURING
CONSTRUCTION
T1-SB
T1-SA
T1-S1
T1-S2
DEMO (E) VENEER BRICK THE
ENTIRE WIDTH AND HEIGHT OF
NEW TOWER
ANTE ROOM
ENTRY POINT
X
LINE OF
NEW CONSTRUCTION
T1-SBT1-SA
T1-S1
T1-S2
X
N E
W
F L O
O R
IN
G
E X
IS
T
IN
G
O
O R
IN
G
01SA-105c1
01SA-105c
01SA-105e
01SA-105e
T1-SB
T 1-
G
PUBLIC ELEV.
P1
73 SF
VAPD CHIEF
GB176A
144 SF
WOMEN
GB175
49 SF
DATA CENTER
GC115-1
851 SF
PUBLIC LOBBY
CG19
961 SF
0"
5' - 5" 1' - 2"
FACE OF STUDS
FACE OF STUDS
IN-03.01-2
T1-SA
1' - 4"
1'
ENTRANCE #2
179 SF
8'
/8
2'
/4
5'
/8
E2C
E2C
02a
02a
02a
T1-S1
T1-S2
WALL TO WALL
EXPANSION
JOINT
5' - 5" 8' - 4 1/2"
169 SF
TR TOWER 1
T1-00G
01S-AE451
1'
/2
3' - 0 3/8"
MECH CHASE
01S-AE451
02a
02a
02a
03b
/2
04a
6' - 7" 7' - 2 3/4" 5 1/2"
IN-01.02
1' - 2"
3" EXPANSION JOINT
IN-01.31
PUBLIC ELEV.
P1
73 SF
VAPD CHIEF
GB176A
144 SF
ENCLOSED
COURTYARD
1585 SF
WOMEN
GB175
49 SF
PUBLIC LOBBY
CG19
961 SF
X
T1-SB
PUBLIC ELEV.
P1
73 SF
WOMEN
GB175
49 SF
PUBLIC LOBBY
CG19
961 SF
VAPD CHIEF
GB176A
144 SF
DATA CENTER
GC115-1
851 SF
EXPOSED
T1-SA
T1-S1
T1-S2
169 SF
TR TOWER 1
T1-00G
2' - 4"
2' - 8"
2' - 4"
3' - 7"
( + ) PRESSURE
CONSTRUCTION ZONE, (--) PRESSURE
TEMPORARY ICRA BARRIER
TEMPORARY ICRA DOOR
CONSTRUCTION TACKY MAT
HEPA EQUIPPED EXHAUST
PUBLIC ELEV.
P1
73 SF
VAPD CHIEF
GB176A
144 SF
ENCLOSED
COURTYARD
1585 SF
WOMEN
GB175
49 SF
PUBLIC LOBBY
CG19
961 SF
TR TOWER 1
01W
0223R 01S
01A
NFPA
TABLE 7.2.1.1 FIRE RESISTANCE RATING FOR TYPE I - 332 (HR)
COLUMNS
SUPPORTING MORE THAN ONE FLOOR 3 HOUR
SUPPORTING ONE FLOOR / ROOF ONLY 2 HOUR
BEAMS
SUPPORTING ONE FLOOR / ROOF ONLY 2 HOUR
FLOOR/CEILING ASSEMBLIES 2 HOUR
ROOF/CEILING ASSEMBLIES 1 1/2 HOUR
INTERIOR/EXTERIOR NONBEARING WALLS 0 HOUR
FIRE RATED REQUIREMENTS
FIRE RATING SCHEDULE
UL
REFERENCE
COLUMNS SUPPORTING ONE FLOOR
HOURLY
RATINGTYPE ELEMENT
I 2 HR UL X854
I COLUMNS SUPPORTING MORE
THAN ONE FLOOR
3 HR UL X854
COLUMNS SUPPORTING ROOFI 2 HR UL X854
FLOOR DECKSI 2 HR UL D779
FLOOR SUPPORTSI 2 HR UL P732
ROOF DECKSI 1 1/2 HR UL P732
ROOF SUPPORTSI 2 HR UL N732
FIRE RATED SCHEDULE
POLYETHYLENE SHEETING
HEPA EQUIPPED AIR FILTER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/0
/2
:5
:4 a m
B
IM
/5
-2
-7
V A
H u n t i n g to n E
H R
M /B
L D
G
S
T R
T O
W E
R .r v t
01SA-100G
BUILDING 01S - LEVEL 00G - TOWER T1 -
DEMO, FLOOR PLANS & RCPS
01S
MA SR/RB
100% CONSTRUCTION
DOCUMENTS
09/03/2025
581-22-700EHRM INFRASTRUCTURE
UPGRADES - HUNTINGTON
VA HUNTINGTON
1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300
LEGEND
1/4" = 1'-0"
LEVEL 00G - TR TOWER 1 - DEMO FLOOR PLAN
PROJECT
NORTH
1/4" = 1'-0"
LEVEL 00G - TR TOWER 1 - DEMO RCP
PROJECT
NORTH
1/4" = 1'-0"
RM T1-00G - FLOOR PLAN
1/4" = 1'-0"
RM T1-00G - RCP
PROJECT
NORTH
PROJECT
NORTH
1. ALL PRODUCTS AND FINISHES SHALL MATCH EXISTING OR
ADJACENT EXISTING UNLESS OTHERWISE NOTED.
2. PATCH AND REPAIR WALLS, FLOORS AND CEILINGS
WHERE MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS
ARE DEMOLISHED.
3. PROTECT FINISHES IN ROOMS ADJACENT TO THE AREA OF
WORK AND PARTS THAT ARE NOT INCLUDED IN THE
SCOPE.
4. CONTRACTOR SHALL LEAVE FIRE RATING STAMP
UNPAINTED AND VISIBLE ON THE NEW INSTALLED FRT
PLYWOOD. SEE DETAIL 5/AE401.
5. REFER TO SHEET AS101 FOR ICRA REQUIREMENTS AND
DETAILS.
6. PATCH AND REPAIR CEILING, WALLS AND FLOORS AS
REQUIRED WHERE ICRA BARRIERS WILL BE CONSTRUCTED
AND REMOVED.
7. REFER TO SHEET A-602 FOR DOOR SCHEDULE.
10 INSTALL TEMPORARY 1 HR CONSTRUCTION ICRA BARRIER TO
SEPARATE CONSTRUCTION AREA FROM OCCUPIED SPACE.
11 INSTALL FIRE RESISTANT TEMPORARY SELF-CLOSING DOOR,
SOLID CORE WOOD IN STEEL FRAME, PAINTED, AT OPENING
AND MATCH RATING OF ICRA BARRIER, TYPICAL.
12 PLACE TACKY MATS AT ENTRANCE AND EXIT OF
CONSTRUCTION AREA, MINIMUM SIZE 24"x36", TYPICAL.
13 INSTALL POLYETHYLENE SHEETING TO ISOLATE
CONSTRUCTION ZONE. TAPE AND SEAL ALONG EDGES, AND
ANY AREAS WHERE POTENTIAL DUST MAY BE EXPOSED
OUTSIDE OF CONSTRUCTION AREA.
1 DEMOLISH PORTION OF EXISTING WALL. PREPARE FOR NEW
DOOR/FRAME.
2 DEMOLISH EXISTING WINDOW/FRAME.
3 INSTALL NEW DOOR/FRAME.
4 CONSTRUCT NEW WALL.
5 INFILL WALL.
6 CONSTRUCT NEW FLOOR.
7 APPLY ANTI-STATIC COATING TO EXPOSED FLOOR. PROVIDE
VINYL REDUCER STRIP AT EXISTING FLOORING TRANSITION.
8 INSTALL NEW RESILIENT RUBBER BASE AT ROOM PERIMETER
WITH SEALANT AT THE BOTTOM.
9 INSTALL FRT PLYWOOD OVER WALLS AS NEEDED PER DETAIL
3/AE401, TYPICAL.
GENERAL NOTES
KEY PLAN
KEY NOTES (THIS SHEET ONLY)
LEGEND
TEMPORARY BARRIER WILL TEMPORARILY
BLOCK ACCESS TO RM GB175.
COORDINATE WORK WITH COR.
ICRA LEGEND
ICRA KEYNOTES
ICRA CLASS IV LEGEND
ICRA CLASS II LEGEND
09/03/20259/3/2025 081 OF 693
W
X
TO DEMOLISH
EXISTING DOOR TO REMAIN
EXISTING DOOR TO DEMOLISH
NEW DOOR
1 HR FIRE RATED WALL
SMOKE RATED WALL
NEW LIGHTS (SEE ELECTRICAL DETAILS)
2 HR FIRE RATED WALL
MOTION DETECTOR
SPRINKLER HEAD
KEY AREA SHOWN
PROJECT
NORTH
O P Q
FOOTPRINT OF NEW
CONSTRUCTION
PREPARE AREA FOR
NEW CONSTRUCTION.
TEMPORARY LOCATION OF EXHAUST.
MOVE INSIDE NEW TR ONCE FEASIBLE.
SEAL WINDOW DURING
CONSTRUCTION
SEAL DOOR DURING
CONSTRUCTION
SEAL DOOR DURING
CONSTRUCTION
DUCT TO EXTERIOR
TYPE IV BARRIER WILL TEMPORARILY BLOCK
ACCESS TO RM GB166a. COORDINATE WORK
WITH COR. BARRIER WILL ONLY BE IN PLACE
DURING DEMOLITION AND INSTALLATION OF
NEW DOOR, AND SHOULD BE IN PLACE FOR
THE SHORTEST PERIOD OF TIME POSSIBLE
17' - 11 1/2"
EXISTING PIPES 1
T4-S1
DEMO (E) VENEER BRICK THE
ENTIRE WIDTH AND HEIGHT OF
NEW TOWER
ANTE ROOM
T4-SA T4-SB
NOTE:
MAINTAIN PASSAGE ACCESS AT ALL TIMES.
INSTALL SEPARATE ICRA BARRIERS ON ONE
WORK AREA AT A TIME.
12 12
13 12
O P Q
LINE OF NEW
CONSTRUCTION
T4-S1
T4-SA T4-SB
O P Q
NEW
FLOORING
EXISTING
FLOORING
166 SF
TR TOWER 4
T4-00G
01SA-105f
01SA-105f
01SA-105d1
01SA-105d
01SA-105d 3
GB166
LAB
235 SF
X-RAY
57 SF
CORRIDOR
CG15
329 SF
CORRIDOR
694 SF
POSTIOGRAPHY
& LAB
GA121
206 SF
TEL
GB166a
35 SF
MECH
GB166
2073 SF
RECEIVING
ENTRY
639 SF
E1C
E1C
E1C
01b
T 4-
G
17' - 0 1/4"
6' - 0 3/4" 10' - 11 1/2"
CLEARANCE
15' - 4 1/2"
C
LE
A R
A N
C E
/4
ELECT PANEL, TYP
IN-03.01-3
WALL TO WALL
EXPANSION JOINT
WALL TO WALL
EXPANSION
JOINT
02a
1/
2"
2' - 7 3/4" 9 1/4"
8 1/4"
1' - 5 1/2"
6" 11 1/2"
T4-S1
04a
5/
8"
3'
1/
2"
1/ 2"
02a
02a
T Y
P 2"
E X
J
9'
3'
6'
2'
/4
/8
4"
FACE OF
STUDS
T4-SA T4-SB
9' - 2 7/8" 5' - 6 3/4" 10' - 5 1/2" 7' - 1 3/8"
4' - 1 7/16"
IN-01.31
O P Q
EXPOSED
166 SF
TR TOWER 4
T4-00G
POSTIOGRAPHY
& LAB
GA121
206 SF
CORRIDOR
CG15
329 SF
RECEIVING
ENTRY
639 SF
X-RAY
57 SF
LAB
235 SF
CORRIDOR
694 SF
TEL
GB166a
35 SF
MECH
GB166
2073 SF
T4-S1
AC UNIT
2' - 4"
2' - 4"
2' - 5"
2' - 5"
T4-SA T4-SB
SECURITY
CAMERA
MOTION
DETECTOR
TEL
GB166a
35 SF
MECH
GB166
2073 SF
CORRIDOR
694 SF
POSTIOGRAPHY
& LAB
GA121
206 SF
LAB
235 SF
X-RAY
57 SF
CORRIDOR
CG15
329 SF
( + ) PRESSURE
CONSTRUCTION ZONE, (--) PRESSURE
TEMPORARY ICRA BARRIER
TEMPORARY ICRA DOOR
CONSTRUCTION TACKY MAT
HEPA EQUIPPED EXHAUST
TEL
GB166a
35 SF
MECH
GB166
2073 SF
CORRIDOR
694 SF
POSTIOGRAPHY
& LAB
GA121
206 SF
LAB
235 SF
X-RAY
57 SF
CORRIDOR
CG15
329 SF
TR TOWER 4
01W
0223R 01S
01A
NFPA
TABLE 7.2.1.1 FIRE RESISTANCE RATING FOR TYPE I - 332 (HR)
COLUMNS
SUPPORTING MORE THAN ONE FLOOR 3 HOUR
SUPPORTING ONE FLOOR / ROOF ONLY 2 HOUR
BEAMS
SUPPORTING ONE FLOOR / ROOF ONLY 2 HOUR
FLOOR/CEILING ASSEMBLIES 2 HOUR
ROOF/CEILING ASSEMBLIES 1 1/2 HOUR
INTERIOR/EXTERIOR NONBEARING WALLS 0 HOUR
FIRE RATED REQUIREMENTS
FIRE RATING SCHEDULE
UL
REFERENCE
COLUMNS SUPPORTING ONE FLOOR
HOURLY
RATINGTYPE ELEMENT
I 2 HR UL X854
I COLUMNS SUPPORTING MORE
THAN ONE FLOOR
3 HR UL X854
COLUMNS SUPPORTING ROOFI 2 HR UL X854
FLOOR DECKSI 2 HR UL D779
FLOOR SUPPORTSI 2 HR UL P732
ROOF DECKSI 1 1/2 HR UL P732
ROOF SUPPORTSI 2 HR UL N732
FIRE RATED SCHEDULE
POLYETHYLENE SHEETING
HEPA EQUIPPED AIR FILTER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/0
/2
:5
:5 a m
B
IM
/5
-2
-7
V A
H u n t i n g to n E
H R
M /B
L D
G
S
T R
T O
W E
R .r v t
01SA-200G
BUILDING 01S - LEVEL 00G - TOWER T4
-DEMO, FLOOR PLANS & RCPS
01S
MA SR/RB
100% CONSTRUCTION
DOCUMENTS
09/03/2025
581-22-700EHRM INFRASTRUCTURE
UPGRADES - HUNTINGTON
VA HUNTINGTON
1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300
1/4" = 1'-0"
LEVEL 00G - TR TOWER 4 - DEMO FLOOR PLAN
1/4" = 1'-0"
LEVEL 00G - TR TOWER 4 - DEMO RCP
1/4" = 1'-0"
RM T4-00G - FLOOR PLAN
1/4" = 1'-0"
RM T4-00G - RCP
PROJECT
NORTH
PROJECT
NORTH
PROJECT
NORTH
PROJECT
NORTH
1. ALL PRODUCTS AND FINISHES SHALL MATCH EXISTING OR
ADJACENT EXISTING UNLESS OTHERWISE NOTED.
2. PATCH AND REPAIR WALLS, FLOORS AND CEILINGS
WHERE MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS
ARE DEMOLISHED.
3. PROTECT FINISHES IN ROOMS ADJACENT TO THE AREA OF
WORK AND PARTS THAT ARE NOT INCLUDED IN THE
SCOPE.
4. CONTRACTOR SHALL LEAVE FIRE RATING STAMP
UNPAINTED AND VISIBLE ON THE NEW INSTALLED FRT
PLYWOOD. SEE DETAIL 5/AE401.
5. REFER TO SHEET AS101 FOR ICRA REQUIREMENTS AND
DETAILS.
6. PATCH AND REPAIR CEILING, WALLS AND FLOORS AS
REQUIRED WHERE ICRA BARRIERS WILL BE CONSTRUCTED
AND REMOVED.
7. REFER TO SHEET A-602 FOR DOOR SCHEDULE.
10 INSTALL TEMPORARY 1 HR CONSTRUCTION ICRA BARRIER TO
SEPARATE CONSTRUCTION AREA FROM OCCUPIED SPACE.
11 INSTALL FIRE RESISTANT TEMPORARY SELF-CLOSING DOOR,
SOLID CORE WOOD IN STEEL FRAME, PAINTED, AT OPENING
AND MATCH RATING OF ICRA BARRIER, TYPICAL.
12 PLACE TACKY MATS AT ENTRANCE AND EXIT OF
CONSTRUCTION AREA, MINIMUM SIZE 24"x36", TYPICAL.
13 INSTALL POLYETHYLENE SHEETING TO ISOLATE
CONSTRUCTION ZONE. TAPE AND SEAL ALONG EDGES, AND
ANY AREAS WHERE POTENTIAL DUST MAY BE EXPOSED
OUTSIDE OF CONSTRUCTION AREA, PER DETAIL 2/AS101.
1 DEMOLISH PORTION OF EXISTING WALL. PREPARE FOR NEW
DOOR/FRAME.
2 DEMOLISH EXISTING DOOR/FRAME. PREPARE FOR NEW
DOOR/FRAME.
3 INSTALL NEW DOOR/FRAME.
4 INFILL WALL, PATCH AND PAINT TO MATCH EXISTING.
5 CONSTRUCT NEW WALL.
6 APPLY ANTI-STATIC COATING TO EXPOSED FLOOR. PROVIDE
VINYL REDUCER STRIP AT EXISTING FLOORING TRANSITION.
7 INSTALL NEW RESILIENT RUBBER BASE AT ROOM PERIMETER
WITH SEALANT AT THE BOTTOM.
8 CONSTRUCT NEW FLOOR.
9 THIS SPACE WILL BE UTILIZED FOR NEW
TELECOMMUNICATION ENCLOSURE. PROVIDE NEW FRT
PLYWOOD OVER WALLS PER DETAIL 3/AE401, TYPICAL.
GENERAL NOTES
KEY PLAN
KEY NOTES (THIS SHEET ONLY)
LEGEND
ICRA KEYNOTES
ICRA LEGEND
ICRA CLASS IV LEGEND
ICRA CLASS II LEGEND
09/03/20259/3/2025 082 OF 693
ICRA CLASS III
ICRA CLASS IV
ICRA CLASS II
FIRE EXTINGUISHER CABINETFEC
FIRE EXTINGUISHERFE
BUILDING BOUNDARY LINE
2 HR FIRE RATED WALL
1 HR FIRE RATED WALL
SMOKE RATED WALL
KEY AREA SHOWN
PROJECT
NORTH
A B D E F H I J K L MGC N O P Q R S T U V W X Y Z
133 SF
E.M.S. CHIEF
1A116
67 SF
INT. DESIGN
1A116A
143 SF
E.M.S. SECT.
1A117
E.M.S.
1A117B
127 SF
E.M.S. SUPERS
1A117A
120 SF
HR
1A119
167 SF
HR
1A120
110 SF
HR
1A120A
64 SF
ELEV
P7
165 SF
STAIRS
112 SF
BUS OFFICE PC
1A114
BUS DATA
OFFICE
1A113A
246 SF
CHIEF STAFF
CREDENTIAL
PRIVILEGE
1A113
172 SF
QM INFECTION
CONTROL
1A112B
120 SF
QM
1A112A
133 SF
HR
1A112
IRM
1A111
59 SF
ELEC
1A110
94 SF
F. TLT
1A109A
100 SF
M. TLT
1A109
139 SF
QM
1A108
133 SF
QM
1A107
115 SF
QM
1A106
181 SF
QM
1A105
450 SF
QM
1A104
110 SF
QM
1A103
129 SF
HR
1A102
145 SF
PIV
1A101
89 SF
PIV
1A101A
308 SF
LOBBY
222 SF
STAIRS
22 SF
HAC
1A121
233 SF
HR
1A122
141 SF
HRM
1A123
181 SF
HR
1A124
160 SF
HRM
1A125
126 SF
HR
1A129
117 SF
HR
1A128
112 SF
HR ASST. CHIEF
1A127
166 SF
HR SECT.
1A126
163 SF
CHIEF HRM
1A126A
180 SF
STAIRS
2195 SF
INPATIENT
PHARMACY
1B101
39 SF
HAC
1B102
408 SF
ADMIN OFFICE
1B100
120 SF
PREP
1C106B
170 SF
CHIEF
1B100A
86 SF
ANTE
143 SF
IV ADM
1B101A
CHEMO
1B101B
73 SF
ANTE
182 SF
SECURE
1B101C
58 SF
ELEC
1B103
28 SF
TELE
1B101d
173 SF
SECURE STOR.
1B105C
136 SF
RECEIV.
1B104
107 SF
FLAMM/TOXIC
1B105D
67 SF
COLD RM
1B105E
399 SF
BLOOD BANK
1B105A
81 SF
BLOOD SPEC'L
1B107
48 SF
TLT
1B106
532 SF
SPECIAL
CHEMISTRY
1B105F
54 SF
M. TLT
70 SF
F. TLT
108 59 SF
ROOM
1B114A
44 SF
1B14B 172 SF
BREAK RM
1B114
DI WATER
1B113
136 SF
CHIEF TECH
1B105G
235 SF
SLIDE & BLOCK
1B108A
560 SF
HISTOLOGY
1B108
125 SF
FLOUR. MICRO
1B112
HAC
1B111
117 SF
CHIEF
1B110G
100 SF
RESID.
1B110F
195 SF
CYTOLOGY
1B108C
194 SF
PROSTHETICS
INVENT/DISTR.
1B109
125 SF
HISTO REVIEW
1B109A
161 SF
GROSS RM
1B108B
298 SF
STERIL
1B115
59 SF
COLD
1B116B
651 SF
MICROBIOLOGY
1B116
105 SF
BIO-LAB
1B116A
142 SF
MEN
1B117
144 SF
WOMEN
1B119
HSC
1B118
109 SF
STAFF
1B110A
101 SF
STAFF
1B110B
213 SF
STAFF
1B110C
219 SF
SEC'Y
226 SF
LAB SERVICE
1B110
112 SF
STAIRS
62 SF
ELEC
1B120a
TRAINING
DIRECTOR
ROOM
1B121
CONF.
113 INSTR. STOR.
148 SF
WOMEN
154 SF
MEN
ELEC
SIG/PH
138 SF
STAIRS
S-1
408 SF
LAB
135 SF
STORAGE
60 SF
H.A.C.
408 SF
LAB
225 SF
LAB
135 SF
LOUNGE
325 SF
BSL
107B
405 SF
LAB
254 SF
SEC'Y CLERICAL
99 SF
WP/
COMPUTER
157 SF
COPY
52 SF
LAB
105A
54 SF
LAB
105B
50 SF
LAB
105C
129 SF
ADM. OFFICE
110B
ASSOC. CHIEF
STAFF
110A
472 SF
GEN. LAB.
114 SF
ANTE
107A
TLT
107C
54 SF
TLT
1C106
36 SF
TELE
1C105
107 SF
PM & R
1B134E
103 SF
PM & R
1B134D
184 SF
PM & R ADMIN
1B134
127 SF
PM & R
1B134C
135 SF
PM & R
1B134A
215 SF
CHIEF PM &R
1B134B
FEMALE TOILET
1B133
MALE TOILET
1B132
169 SF
STAIR
P R
O S
T H
E T
IC
S
O F
F
IC
E
B
PROSTHETICS
OFFICE
1B127A
21 SF
TRASH CH
1B128
21 SF
LINEN CH
1B129
68 SF
ELEC
1B
TELE
1B130
117 SF
1B126L
180 SF
FITTING
1B126J
110 SF
FITTING
1B1261
S F
H
IS
A P
R O
G
B
H
S
F
L A
B F
U M
E
B
G
64 SF
CPO
1B126F
82 SF
BREAK
1B126E
PLSTR
1B126D
294 SF
STORAGE
1B126K
CORRIDOR
1B126A98 SF
ORTHO
1B126B
85 SF
RECEP
1B126C
83 SF
RECEP
1B125A
508 SF
WAITING
1B126
195 SF
EXAM PROC
1B125C
132 SF
PHYS
1B125D
191 SF
EXAM
1B125H14 SF
LIN
1B125G
40 SF
1B125E
211 SF
1B125F
196 SF
1B125M
57 SF
WC TOILET
1B1251
44 SF
TOILET
1B125J
72 SF
ELEC
1B125Q
32 SF
IT
1B125P
191 SF
1B125O
295 SF
P.T.
1B125I
1497 SF
PT TREATMENT /
CT EXERCISE
1B125K
134 SF
1B125N
163 SF
STAIR
111 SF
SPEECH
1B124D
106 SF
EXAM D
1B124G
105 SF
EXAM E
1B124F
180 SF
POLYTRAUMA
1B124E
61 SF
1B124A
131 SF
1B123E 50 SF
ELEC
1B1241
90 SF
1B124B
130 SF
1B123D
168 SF
1B123C
285 SF
ORTHOTICS
SPLINT
1B124C
218 SF
1B123B
123 SF
1B123A
378 SF
CONFERENCE
1B122H
160 SF
AAD
1B122I
300 SF
PR / QA
1B122
113 SF
1B123201 SF
ADP FILES
1B122K246 SF
WAIT
1B122L
549 SF
SEC'Y
119 SF
PASS
1B1221
PASS
1B122M
274 SF
ASSOC.
DIRECTOR
1B122F
348 SF
DIRECTOR
1B122E
307 SF
COS
1B122D
153 SF
AA / COS
1B122A
STOR
1B122B
KITCHEN
1B122C
576 SF
CORRIDOR
C1-8
395 SF
CORRIDOR
C1-9
1463 SF
CORRIDOR
C1-4
CONN.
CORRIDOR TO
BUILDING
1S
243 SF
CORRIDOR
C1-15
283 SF
SERVICE LOBBY
C1-14
296 SF
PUBLIC LOBBY
C1-17
235 SF
SPECIMEN
ACCESSION
1B105H
306 SF
BULK STORAGE
1B105B
S
F
C O
R R
ID
O
R
C
-5
421 SF
CORRIDOR
C1-6
2107 SF
GENERAL LAB
1B105
982 SF
CHAPEL
1C106D
702 SF
CORRIDOR
C1-10
223 SF
CORRIDOR
C1-13
134 SF
CORRIDOR
C1-12
S
F
C O
R R
ID
O
R
C
-1
CHILLER PLANT
BUILDING #1S
ELEVATOR
SE -
42 SF
MECH
SHAFT
SE-2
41 SF
SAFETY
ALCOVE
SE-3
196 SF
STR 3
C O
R R
C
-7
101 SF
ELEV
S-2
100 SF
ELEV
33 SF
1B120b
375 SF
LAB
WOMENS TLT
SHOWER
51 SF
ELEC.
ROOM
366 SF
FACULTY LAB
173 SF
SECRETARY
CLERK
121 SF
CHAIRMAN
OFFICE
128A
28 SF
SAFETY
ALCOVE
SE -
2185 SF
MARSHALL
CAMPUS
770 SF
CORRIDOR
C1-3
404 SF
CHAIRMAN LAB
184 SF
S-2
64 SF
P-2
83 SF
73 SF
131A
220 SF
379 SF
87 SF
132A
96 SF
133A
178 SF
226 SF
98 SF
134A
203 SF
C1-5
111 SF
206 SF
171 SF
135A
396 SF
88 SF
121A
94 SF
124A
187 SF
188 SF
96 SF
96 SF
125A
43 SF
136D
828 SF
BUILDING 01S
PHASE 1:
CONTRACTOR TO COMPLETE THE WORK OF THIS TR
AND ASSOCIATED DATA DROPS. COMPLETE ONE
SECTION AT A TIME AS DIRECTED TO COR.
BUILDING 01S
PHASE 2:
CONTRACTOR TO COMPLETE THE WORK OF THIS TR AND
ASSOCIATED DATA DROPS. COMPLETE ONE SECTION AT A
TIME AS DIRECTED TO COR.
BUILDING 01S
SECTION 1A:
CONTRACTOR TO COORDINATE WITH VA FOR
ROOM CLOSURES AND AVAILABILITY TO COMPLETE
DATA WIRING IN THIS AREA.
BUILDING 01A
SECTION 1B:
CONTRACTOR TO COORDINATE WITH VA FOR
ROOM CLOSURES AND AVAILABILITY TO COMPLETE
DATA WIRING IN THIS AREA.
BUILDING 01S
SECTION 1C:
CONTRACTOR TO COORDINATE WITH VA FOR ROOM
CLOSURES AND AVAILABILITY TO COMPLETE DATA
WIRING IN THIS AREA.
BUILDING01S
SECTION 1E:
CONTRACTOR TO COORDINATE WITH VA FOR ROOM
CLOSURES AND AVAILABILITY TO COMPLETE DATA
WIRING IN THIS AREA.
BUILDING 01S
SECTION 1D:
CONTRACTOR TO COORDINATE WITH VA FOR
ROOM CLOSURES AND AVAILABILITY TO COMPLETE
DATA WIRING IN THIS AREA.
BUILDING 23
SECTION 2C:
CONTRACTOR TO COORDINATE WITH VA FOR
ROOM CLOSURES AND AVAILABILITY TO COMPLETE
DATA WIRING IN THIS AREA.
BUILDING 23
SECTION 2B:
CONTRACTOR TO COORDINATE WITH VA FOR ROOM
CLOSURES AND AVAILABILITY TO COMPLETE DATA
WIRING IN THIS AREA.
BUILDING 01S
SECTION 2A:
CONTRACTOR TO COORDINATE WITH VA FOR
ROOM CLOSURES AND AVAILABILITY TO
COMPLETE DATA WIRING IN THIS AREA.
BUILDING 12
SECTION 2E:
CONTRACTOR TO COORDINATE WITH VA FOR
ROOM CLOSURES AND AVAILABILITY TO COMPLETE
DATA WIRING IN THIS AREA.
BLDG. 23
BLDG. 23R
BLDG. 12
BLDG. 01A
BLDG. 01
BLDG. 01S
BLDG. 02
TR TOWER 4
T4-01
160 SF
TR TOWER 1
T1-01
166 SF
PER VA GUIDANCE THIS
SPACE IS OUT OF SCOPE.
FEC
NEW SEMI-RECESSED FEC, TO MATCH
OR EXCEED EXISTING EXTINGUISHER IN
ABC RATING AND SIZE. SEE DET 4/A-604.
FEC
NEW SEMI-RECESSED FEC, TO MATCH
OR EXCEED EXISTING EXTINGUISHER IN
ABC RATING AND SIZE. SEE DET 4/A-604.
140 SF
HR
1A122A SPACE FOR NEW
DATA CENTER
23RA-100C
TR TOWER 4
TR TOWER 1
01W
0223R 01S
01A 01
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/0
/2
:3
:4 a m
B
IM
/5
-2
-7
V A
H u n t i n g to n E
H R
M /B
L D
G
L E
V E
L
.r v t 01SAS101
BUILDING 01S - LEVEL 01 - PHASING PLAN
01S
MA RB
100% CONSTRUCTION
DOCUMENTS
09/03/2025
581-22-700EHRM INFRASTRUCTURE
UPGRADES - HUNTINGTON
VA HUNTINGTON
1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300
KEY PLAN
LEGEND
PROJECT
NORTH
1" = 20'-0"
BUILDING 01S - LEVEL 01 - PHASING PLAN
09/03/20259/3/2025 083 OF 693
W
X
C
360°
W
X
C
360°
TO DEMOLISH
EXISTING DOOR TO REMAIN
EXISTING DOOR TO DEMOLISH
NEW DOOR
1 HR FIRE RATED WALL
SMOKE RATED WALL
NEW LIGHTS (SEE ELECTRICAL DETAILS)
2 HR FIRE RATED WALL
MOTION DETECTOR
SPRINKLER HEAD
X
T1-SB
FOOTPRINT OF NEW
CONSTRUCTION
PREPARE AREA FOR
NEW CONSTRUCTION.
TEMPORARY LOCATION OF EXHAUST.
MOVE INSIDE NEW TR ONCE FEASIBLE.
SEAL DOOR DURING
CONSTRUCTION
FEMALE TOILET
1B133
49 SF
CHIEF PM &R
1B134B
215 SF
CORRIDOR
432 SF
T1-SA
T1-S1
T1-S2
DEMO (E) VENEER BRICK THE
ENTIRE WIDTH AND HEIGHT OF
NEW TOWER
ENTRY POINT
12 12
ANTE ROOM
11 X
T1-SB
LINE OF
NEW CONSTRUCTION
CORRIDOR
432 SF
FEMALE TOILET
1B133
49 SF
CHIEF PM &R
1B134B
215 SF
T1-SA
T1-S1
T1-S2
X
01SA-105e
01SA-105e
T1-SB
166 SF
TR TOWER 1
T1-01
T 1-
FEMALE TOILET
1B133
49 SF
CORRIDOR
432 SF
CHIEF PM &R
1B134B
215 SF
PM & R
1B134C
127 SF
NEW
FLOORING
EXISTING
FLOORING
CLEARANCE
10' - 4 7/8"
/4
C
LE
A R
A N
C E
6' - 7" 7' - 2 3/4" 5 5/8"
IN-03.01-5
T1-SA
2'
1/ 4"
E2C
02a
E2C
T1-S1
T1-S2
1/
2" 8'
/8
2'
/4
5'
/8
13' - 9 3/4"
8" 8"
5 1/2"
01S-AE451
02a
02a
01S-AE451
04a
1'
0"
3' - 3 7/8"
03b
02a
02a
02a
WALL TO WALL
EXPANSION
JOINT
IN-01.31
/2
FACE OF STUDS
FACE OF STUDS
FACE OF STUDS
1' - 2"
3" EXPANSION JOINT
MALE TOILET
1B132
50 SF
X
T1-SB
166 SF
TR TOWER 1
T1-01
FEMALE TOILET
1B133
49 SF
CORRIDOR
432 SF
CHIEF PM &R
1B134B
215 SF
PM & R
1B134C
127 SF
EXPOSED
T1-SA
T1-S1
T1-S2
1' - 11"
1' - 11"2' - 6"
3' - 9"
TR TOWER 1
01W
0223R 01S
01A 01
KEY AREA SHOWN
PROJECT
NORTH
NFPA
TABLE 7.2.1.1 FIRE RESISTANCE RATING FOR TYPE I - 332 (HR)
COLUMNS
SUPPORTING MORE THAN ONE FLOOR 3 HOUR
SUPPORTING ONE FLOOR / ROOF ONLY 2 HOUR
BEAMS
SUPPORTING ONE FLOOR / ROOF ONLY 2 HOUR
FLOOR/CEILING ASSEMBLIES 2 HOUR
ROOF/CEILING ASSEMBLIES 1 1/2 HOUR
INTERIOR/EXTERIOR NONBEARING WALLS 0 HOUR
FIRE RATED REQUIREMENTS
FIRE RATING SCHEDULE
UL
REFERENCE
COLUMNS SUPPORTING ONE FLOOR
HOURLY
RATINGTYPE ELEMENT
I 2 HR UL X854
I COLUMNS SUPPORTING MORE
THAN ONE FLOOR
3 HR UL X854
COLUMNS SUPPORTING ROOFI 2 HR UL X854
FLOOR DECKSI 2 HR UL D779
FLOOR SUPPORTSI 2 HR UL P732
ROOF DECKSI 1 1/2 HR UL P732
ROOF SUPPORTSI 2 HR UL N732
FIRE RATED SCHEDULE
( + ) PRESSURE
CONSTRUCTION ZONE, (--) PRESSURE
TEMPORARY ICRA BARRIER
TEMPORARY ICRA DOOR
CONSTRUCTION TACKY MAT
HEPA EQUIPPED EXHAUST
POLYETHYLENE SHEETING
HEPA EQUIPPED AIR FILTER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/0
/2
:5
:4 a m
B
IM
/5
-2
-7
V A
H u n t i n g to n E
H R
M /B
L D
G
S
T R
T O
W E
R .r v t
01SA-101
BUILDING 01S - LEVEL 01 - TOWER T1 -DEMO,
FLOOR PLANS & RCPS
01S
MA SR/RB
100% CONSTRUCTION
DOCUMENTS
09/03/2025
581-22-700EHRM INFRASTRUCTURE
UPGRADES - HUNTINGTON
VA HUNTINGTON
1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300
1. ALL PRODUCTS AND FINISHES SHALL MATCH EXISTING OR
ADJACENT EXISTING UNLESS OTHERWISE NOTED.
2. PATCH AND REPAIR WALLS, FLOORS AND CEILINGS
WHERE MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS
ARE DEMOLISHED.
3. PROTECT FINISHES IN ROOMS ADJACENT TO THE AREA OF
WORK AND PARTS THAT ARE NOT INCLUDED IN THE
SCOPE.
4. CONTRACTOR SHALL LEAVE FIRE RATING STAMP
UNPAINTED AND VISIBLE ON THE NEW INSTALLED FRT
PLYWOOD. SEE DETAIL 5/AE401.
5. REFER TO SHEET AS101 FOR ICRA REQUIREMENTS AND
DETAILS.
6. PATCH AND REPAIR CEILING, WALLS AND FLOORS AS
REQUIRED WHERE ICRA BARRIERS WILL BE CONSTRUCTED
AND REMOVED.
7. REFER TO SHEET A-602 FOR DOOR SCHEDULE.
10 INSTALL TEMPORARY 1 HR CONSTRUCTION ICRA BARRIER TO
SEPARATE CONSTRUCTION AREA FROM OCCUPIED SPACE.
11 INSTALL FIRE RESISTANT TEMPORARY SELF-CLOSING DOOR,
SOLID CORE WOOD IN STEEL FRAME, PAINTED, AT OPENING
AND MATCH RATING OF ICRA BARRIER, TYPICAL.
12 PLACE TACKY MATS AT ENTRANCE AND EXIT OF
CONSTRUCTION AREA, MINIMUM SIZE 24"x36", TYPICAL.
13 INSTALL POLYETHYLENE SHEETING TO ISOLATE
CONSTRUCTION ZONE. TAPE AND SEAL ALONG EDGES, AND
ANY AREAS WHERE POTENTIAL DUST MAY BE EXPOSED
OUTSIDE OF CONSTRUCTION AREA.
1 DEMOLISH PORTION OF EXISTING WALL. PREPARE FOR NEW
DOOR/FRAME.
2 DEMOLISH EXISTING WINDOW/FRAME.
3 INSTALL NEW DOOR/FRAME.
4 CONSTRUCT NEW WALL.
5 INFILL WALL.
6 CONSTRUCT NEW FLOOR.
7 APPLY ANTI-STATIC COATING TO EXPOSED FLOOR. PROVIDE
VINYL REDUCER STRIP AT EXISTING FLOORING TRANSITION.
8 INSTALL NEW RESILIENT RUBBER BASE AT ROOM PERIMETER
WITH SEALANT AT THE BOTTOM.
9 INSTALL FRT PLYWOOD OVER WALLS AS NEEDED PER DETAIL
3/AE401, TYPICAL.
GENERAL NOTES
KEY PLAN
KEY NOTES (THIS SHEET ONLY)
LEGEND
ICRA LEGEND
1/4" = 1'-0"
LEVEL 01 - TR TOWER 1 - DEMO FLOOR PLAN
1/4" = 1'-0"
LEVEL 01 - TR TOWER 1 - DEMO RCP
1/4" = 1'-0"
RM T1-01 - FLOOR PLAN
1/4" = 1'-0"
RM T1-01 - RCP
PROJECT
NORTH
PROJECT
NORTH
PROJECT
NORTH
PROJECT
NORTH
TEMPORARY BARRIER WILL
TEMPORARILY BLOCK ACCESS TO RM
1B133. COORDINATE WORK WITH
COR.
ICRA KEYNOTES
ICRA CLASS IV LEGEND
ICRA CLASS II LEGEND
09/03/20259/3/2025 084 OF 693
W
X
C
360°
W
X
360°
C
TO DEMOLISH
EXISTING DOOR TO REMAIN
EXISTING DOOR TO DEMOLISH
NEW DOOR
1 HR FIRE RATED WALL
SMOKE RATED WALL
NEW LIGHTS (SEE ELECTRICAL DETAILS)
2 HR FIRE RATED WALL
MOTION DETECTOR
SPRINKLER HEAD
O P Q
FOOTPRINT OF NEW
CONSTRUCTION
PREPARE AREA FOR
NEW CONSTRUCTION.
17' - 7 1/4"
/4
TEMPORARY LOCATION OF
EXHAUST.
MOVE INSIDE NEW TR ONCE
FEASIBLE.
SEAL WINDOW DURING
CONSTRUCTION
SEAL WINDOW DURING
CONSTRUCTION
TRAINING
DIRECTOR ROOM
1B121
1119 SF
CORRIDOR
C1-9
395 SF
CORRIDOR
C1-4
1463 SF
E.M.S. CHIEF
1A116
133 SF
1B120b
33 SF
T4-S1
ANTE ROOM
9T4-SA T4-SB
O P Q
LINE OF NEW
CONSTRUCTION
TRAINING
DIRECTOR ROOM
1B121
1119 SF
1B120b
33 SF
CORRIDOR
C1-9
395 SF
CORRIDOR
C1-4
1463 SF
E.M.S. CHIEF
1A116
133 SF
T4-S1
T4-SA T4-SB
O P Q
160 SF
TR TOWER 4
T4-01
01SA-105f
01SA-105f
01SA-105d1
01SA-105d
01SA-105d 3
T 4-
N
E W
O
O R
IN
G
EXISTING
FLOORING
E1C
E1C
E1C
4 5 6
15' - 4 1/2" CLEARANCE11
/8
C
LE
A R
A N
C E
1/
2"
/4
8' - 8 1/2" 17' - 1 1/4"
DATA RACK
ELECT PANEL
TRAINING
DIRECTOR ROOM
1B121
1119 SF
E.M.S. CHIEF
1A116
133 SF
CORRIDOR
C1-4
1463 SF
1B120b
33 SF
CORRIDOR
C1-9
395 SF
IN-03.01-6 WALL TO WALL
EXPANSION JOINT
WALL TO WALL
EXPANSION JOINT
8 3/4" 9 1/4"
1' - 6"
9 1/4" 8 3/4"
1/
2"
T4-S1
1/
2"
1/ 2"
2'-6"x1'-0"
DUCT CHASE
3'
5/
8"
02a
04a
02a
02a
01S-A-501
T4-SA T4-SB
IN-01.31
O P Q
EXPOSED
160 SF
TR TOWER 4
T4-01
TRAINING
DIRECTOR ROOM
1B121
1119 SF
CORRIDOR
C1-9
395 SF
CORRIDOR
C1-4
1463 SF
E.M.S. CHIEF
1A116
133 SF
1B120b
33 SF
T4-S1
AC UNIT
1' - 10" 1' - 10"
1' - 10"1' - 10"
T4-SA T4-SB
TR TOWER 4
01W
0223R 01S
01A 01
KEY AREA SHOWN
PROJECT
NORTH
( + ) PRESSURE
CONSTRUCTION ZONE, (--) PRESSURE
TEMPORARY ICRA BARRIER
TEMPORARY ICRA DOOR
CONSTRUCTION TACKY MAT
HEPA EQUIPPED EXHAUST
NFPA
TABLE 7.2.1.1 FIRE RESISTANCE RATING FOR TYPE I - 332 (HR)
COLUMNS
SUPPORTING MORE THAN ONE FLOOR 3 HOUR
SUPPORTING ONE FLOOR / ROOF ONLY 2 HOUR
BEAMS
SUPPORTING ONE FLOOR / ROOF ONLY 2 HOUR
FLOOR/CEILING ASSEMBLIES 2 HOUR
ROOF/CEILING ASSEMBLIES 1 1/2 HOUR
INTERIOR/EXTERIOR NONBEARING WALLS 0 HOUR
FIRE RATED REQUIREMENTS
FIRE RATING SCHEDULE
UL
REFERENCE
COLUMNS SUPPORTING ONE FLOOR
HOURLY
RATINGTYPE ELEMENT
I 2 HR UL X854
I COLUMNS SUPPORTING MORE
THAN ONE FLOOR
3 HR UL X854
COLUMNS SUPPORTING ROOFI 2 HR UL X854
FLOOR DECKSI 2 HR UL D779
FLOOR SUPPORTSI 2 HR UL P732
ROOF DECKSI 1 1/2 HR UL P732
ROOF SUPPORTSI 2 HR UL N732
FIRE RATED SCHEDULE
POLYETHYLENE SHEETING
HEPA EQUIPPED AIR FILTER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/0
/2
:5
:5 a m
B
IM
/5
-2
-7
V A
H u n t i n g to n E
H R
M /B
L D
G
S
T R
T O
W E
R .r v t
01SA-201
BUILDING 01S - LEVEL 01 - TOWER T4 -DEMO,
FLOOR PLANS & RCPS
01S
MA SR/RB
100% CONSTRUCTION
DOCUMENTS
09/03/2025
581-22-700EHRM INFRASTRUCTURE
UPGRADES - HUNTINGTON
VA HUNTINGTON
1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300
1. ALL PRODUCTS AND FINISHES SHALL MATCH EXISTING OR
ADJACENT EXISTING UNLESS OTHERWISE NOTED.
2. PATCH AND REPAIR WALLS, FLOORS AND CEILINGS
WHERE MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS
ARE DEMOLISHED.
3. PROTECT FINISHES IN ROOMS ADJACENT TO THE AREA OF
WORK AND PARTS THAT ARE NOT INCLUDED IN THE
SCOPE.
4. CONTRACTOR SHALL LEAVE FIRE RATING STAMP
UNPAINTED AND VISIBLE ON THE NEW INSTALLED FRT
PLYWOOD. SEE DETAIL 5/AE401.
5. REFER TO SHEET AS101 FOR ICRA REQUIREMENTS AND
DETAILS.
6. PATCH AND REPAIR CEILING, WALLS AND FLOORS AS
REQUIRED WHERE ICRA BARRIERS WILL BE CONSTRUCTED
AND REMOVED.
7. REFER TO SHEET A-602 FOR DOOR SCHEDULE.
GENERAL NOTES
KEY PLAN
KEY NOTES (THIS SHEET ONLY)
LEGEND
ICRA LEGEND
1/4" = 1'-0"
LEVEL 01 - TR TOWER 4 - DEMO FLOOR PLAN
1/4" = 1'-0"
LEVEL 01 - TR TOWER 4 - DEMO RCP
1/4" = 1'-0"
RM T4-01 - FLOOR PLAN
1/4" = 1'-0"
RM T4-01 - RCP
PROJECT
NORTH
PROJECT
NORTH
PROJECT
NORTH
PROJECT
NORTH
8 INSTALL TEMPORARY 1 HR CONSTRUCTION ICRA BARRIER TO
SEPARATE CONSTRUCTION AREA FROM OCCUPIED SPACE.
9 INSTALL FIRE RESISTANT TEMPORARY SELF-CLOSING DOOR,
SOLID CORE WOOD IN STEEL FRAME, PAINTED, AT OPENING
AND MATCH RATING OF ICRA BARRIER, TYPICAL.
10 PLACE TACKY MATS AT ENTRANCE AND EXIT OF
CONSTRUCTION AREA, MINIMUM SIZE 24"x36", TYPICAL.
1 DEMOLISH PORTION OF EXISTING WALL. PREPARE FOR NEW
DOOR/FRAME.
2 INSTALL NEW DOOR/FRAME.
3 CONSTRUCT NEW WALL.
4 CONSTRUCT NEW FLOOR.
5 APPLY ANTI-STATIC COATING TO EXPOSED FLOOR. PROVIDE
VINYL REDUCER STRIP AT EXISTING FLOORING TRANSITION.
6 INSTALL NEW RESILIENT RUBBER BASE AT ROOM PERIMETER
WITH SEALANT AT THE BOTTOM.
7 INSTALL FRT PLYWOOD OVER WALLS AS NEEDED PER DETAIL
3/AE401, TYPICAL.
ICRA KEYNOTES
ICRA CLASS IV LEGEND
ICRA CLASS II LEGEND
09/03/20259/3/2025 085 OF 693
ICRA CLASS III
ICRA CLASS IV
ICRA CLASS II
FIRE EXTINGUISHER CABINETFEC
FIRE EXTINGUISHERFE
BUILDING BOUNDARY LINE
2 HR FIRE RATED WALL
1 HR FIRE RATED WALL
SMOKE RATED WALL
KEY AREA SHOWN
PROJECT
NORTH
A B D E F H I J K L MGC N O P Q R S T U V W X Y Z
142 SF
EXAM
2B100a
EXAM
2B100b
C A
R D
IO
L
O G
Y /E
K G
B
134 SF
EXAM
2C100G
99 SF
CARDIOLOGY
OFFICE
2B101
148 SF
EXAM
2B100f
201 SF
EXAM
2B100e
191 SF
SPECIAL BREAK
EQUIP. RM.
2B107
72 SF
CLEAN UTIL.
2B106
75 SF
2B105a
192 SF
SCRUB
2B104
2B105
593 SF
CARDIOLOGY
2B108
236 SF
EXAM
2B100c
201 SF
EXAM
2B100d
CONTROL
2B108a
F. TLT
2B112a
53 SF
LKR
2B112
49 SF
LKR
2B111
MEN
33 SF
HAC
2B110 49 SF
SOIL.
2B109165 SF
STAIR
CLERK
2B200A
RESID. LAB
2B197
202 SF
RESID.
FELL/STUD
2B199
298 SF
WAITING
2B200
123 SF
EXAM
2B102
124 SF
EXAM
2B103
355 SF
CARDIAC
HOLDING
2B11458 SF
ELEC.
2B116
28 SF
TELE
2B115
121 SF
CHIEF TECH.
2B117
134 SF
LOUNGE
2B119
124 SF
M.TLT.
2B121
94 SF
F.TLT.
2B123
270 SF
ULTRA - SOUND
2B124
DRESS
2B127
DRS
DRS
DRSDRSWC TLT
2B122a
159 SF
WC STRET
2B130a
285 SF
RADIO FLOUR.
2B122
298 SF
RADIO FLOUR
2B120
WC TLT
2B120a
188 SF
2A130A
168 SF
2A130
106 SF
2A129
127 SF
2A128
146 SF
F. TLT
2A12669 SF
SUP
2A127
23 SF
2A125
ELEV
P7
117 SF
OFFICE
2A124
199 SF
CHF. S.W.
2A123
93 SF
OFFICE
2A122C
VEST.
2A122
96 SF
OFFICE
2A122B
103 SF
2A122A
113 SF
2A121
114 SF
2A117
107 SF
2A116
117 SF
2A115
131 SF
2A120
CARDIOLOGY
PASSAGE
2B198
54 SF
ELEC. CLO
2B97b
CORRIDOR
C2-6
231 SF
DED. CHEST
2B131
184 SF
2B132a
176 SF
FILM
2B13280 SF
EQUIP
2B136
42 SF
UPS
102 SF
CLEAN
2B135
SOIL UTIL.
2B137
290 SF
G.P. ROOM
2B153
277 SF
G.P. ROOM
2B152
277 SF
AUTOMATED
2B148 94 SF
VIEW
2B144
49 SF
HAC
2B138
DRS
DRS
292 SF
RECEP. NUC.
MED.
2B167a
82 SF
DARK RM
2B184
67 SF
PT. TLT
2B
1403 SF
NUCLEAR
MEDICINE
2B186
222 SF
WAITING
2B167
71 SF
ELEC
2B168
32 SF
TELE
2B
45 SF
HAC
2B170
68 SF
MEN
2B171a
131 SF
LOUNGE
2B171
58 SF
WC TOIL
2B171b
287 SF
CORRIDOR
C2-42
208 SF
DR. OFFICE
2B180
194 SF
VIEW/CONF.
2B172
140 SF
STOR
2B173
164 SF
SECY\
2B17943 SF
STOR.
2B178
161 SF
ULTRASOUND
2B180a
162 SF
ULTRA SOUND
2B181
230 SF
SCAN THYROID
2B182
359 SF
SCAN
STATIONARY
2B185
154 SF
HIGH LEVEL
IN-VITRO
2B187
150 SF
WAITING RM
2B188
240 SF
CORRIDOR
C2-15
290 SF
SERVICE LOBBY
C2-16
403 SF
I/R SUITE
2B118
BARIUM PREP
2B133
CORRIDOR
C O
R R
ID
O
R
50 SF
2B171c
827 SF
CORRIDOR
C2-13 178 SF
STR 4
ISOTOPIC STOR
GL WASH &
STER PREP RM
2B177
223 SF
LOUNGE
2B176
135 SF
2B175
155 SF
2B174
874 SF
FILE STORAGE
2B166f
ELEC CLOSET
150 SF
CLERK TYP.
2B165
127 SF
SEC'Y
2B164
C O
M M
O N
V
IE
W
B
113 SF
CHIEF
2B162
163 SF
MRI EQUIP SCAN
RM
2B166b
46 SF
DRESS
2B166c
MRI WAITING
2B161a
222 SF
CORRIDOR
C2-14
239 SF
COMPUTER
2B145a
157 SF
READING
2B145
26 SF
HAC
2B151
TLT
2B15463 SF
ELECT. CLO.
2B155a
35 SF
TELE. CLO.
2B155b
2067 SF
MECH
2B155
300 SF
CORRIDOR
C2-41
368 SF
IMAGING
LOUNGE
2B160
240 SF
IRM
2B159
163 SF
IRM
2B158
619 SF
COMPUTER
TRAINING
2B156
198 SF
STAIR
58 SF
CONTROL ROOM
111 SF
STAIR
118 SF
2A119
CORRIDOR
C2-11
356 SF
INPT BEDS
2B161
489 SF
CT BRIGHTSCR
2B146
508 SF
32 SLICE CT
2B149
227 SF
CONTROL RM
2B147
274 SF
MRI CONTROL
2B166d
373 SF
MRI SCAN ROOM
2B166a
529 SF
CORRIDOR
C2-12
C O
R R
ID
O
R
C
-1
162 SF
STAIR
142 SF
2A114
164 SF
2A113A
160 SF
2A113
92 SF
KITCHEN
2A112
HAC
2A111
ELEC
2A110
SUP
2A108
127 SF
MEN
2A107
741 SF
LIBRARY
662 SF
CORRIDOR
568 SF
WALSH
CONFERENCE
2A100
134 SF
2A101a
112 SF
STAIRS
124 SF
LRC EQUIP
2A135
124 SF
EDUC ASST
2A134
87 SF
VISUAL INFO.
SPEC.
2A133
188 SF
2A101b
125 SF
2A101
86 SF
ELEV
P - 3
86 SF
ELEV
P - 2
87 SF
ELEV
P - 1
306 SF
PUBLIC LOBBY
C2-18
MEN
2B195
WOMEN
2B196
STAIR
183 SF
EMS
2B189
40 SF
HAC
2B190
21 SF
TRASH CH
2B193
21 SF
LINEN CH
2B194
TELE
2B191
68 SF
ELEC
2B192
96 SF
ELEV
S - 1
120 SF
ELEV
S - 2
C O
R R
ID
O
R
C
-1
895 SF
WAITING
2B130
CORRIDOR
C2-5
1431 SF
CORRIDOR
C2-6
40 SF
CLOSET
2B111b
349 SF
MED. MEDIA
PRODUCTION
2A132
170 SF
EQUIPMENT
2B108b
395 SF
LAB
140 SF
CONTROL TEMP.
156 SF
CONTROL TEMP.
S
F
IN
V
E S
T
O F
F
IC
E
147 SF
STORAGE
98 SF
FLAM STO.
101 SF
INVEST.
OFFICE
522 SF
GLASS WASH
405 SF
LAB
404 SF
LAB
131 SF
STORAGE
41 SF
MECH. SHAFT
153 SF
MEN
148 SF
WOMENS
ELEVATOR
SE-1
1737 SF
SIG./PH
73 SF
ELEC.
215 SF
INSTR.
STORAGE
145 SF
H.S. R&D OFFICE
216A
144 SF
H.S. R & D SEC'Y
407 SF
LAB
411 SF
LAB
20 SF
SAFETY ALCOVE
S A
F E
T Y
A L
C O
V E
106 SF
H.A.C
137 SF
STAIR
905 SF
CORRIDOR
C2-9
147 SF
MEN'S TOILET
54 SF
ELECTRIC
CLOSET
90 SF
STORAGE
226A
87 SF
STORAGE
MARSHALL
CAMPUS
382 SF
FACULTY LAB
35 SF
TELEPHONE
CLOSET
2C180
371 SF
LAB
212 132 SF
WOMEN'S
TOILET
60 SF
ELEC. ROOM
E-123
188 SF
STUDENT
OFFICE
S
F
F A
C U
L T
Y L
A B
95 SF
FACULTY
OFFICE
91 SF
FACULTY
OFFICE
224A
378 SF
FACULTY LAB
1498 SF
LEARNING
RESOURCES
208 SF
S-2
63 SF
P-2
144 SF
217A
181 SF
376 SF
90 SF
216A
90 SF
215A
179 SF
192 SF
90 SF
212A
176 SF
153 SF
209A
19 SF
390 SF
193 SF
103 SF
85 SF
205A
86 SF
206A
244 SF
P-1
192 SF
S-1
693 SF
C2-1
892 SF
C2-2
C2-4
677 SF
C2-3
293 SF
82 SF
84 SF
211A
299 SF
84 SF
201A
86 SF
204A
309 SF
241 SF
60 SF
83 SF
94 SF
84 SF
103 SF
157 SF
229A
217 SF
C2-5
77 SF
370 SF
176 SF
214A
1637 SF
BUILDING 01S
PHASE 2:
CONTRACTOR TO COMPLETE THE WORK OF THIS TR AND
ASSOCIATED DATA DROPS. COMPLETE ONE SECTION AT A
TIME AS DIRECTED TO COR.
BUILDING 01S
SECTION 2A:
CONTRACTOR TO COORDINATE WITH VA FOR
ROOM CLOSURES AND AVAILABILITY TO
COMPLETE DATA WIRING IN THIS AREA.
BUILDING 01S
PHASE 1:
CONTRACTOR TO COMPLETE THE WORK OF THIS
TR AND ASSOCIATED DATA DROPS. COMPLETE
ONE SECTION AT A TIME AS DIRECTED TO COR.
BUILDING 01A & 01S
SECTION 1A:
CONTRACTOR TO COORDINATE WITH VA FOR ROOM
CLOSURES AND AVAILABILITY TO COMPLETE DATA
WIRING IN THIS AREA.
BUILDING 01S
SECTION 1B:
CONTRACTOR TO COORDINATE WITH VA FOR ROOM
CLOSURES AND AVAILABILITY TO COMPLETE DATA
WIRING IN THIS AREA.
BUILDING 23
SECTION 2D:
CONTRACTOR TO COORDINATE WITH VA FOR ROOM
CLOSURES AND AVAILABILITY TO COMPLETE DATA
WIRING IN THIS AREA.
BUILDING 12
SECTION 2B:
CONTRACTOR TO COORDINATE WITH VA FOR ROOM
CLOSURES AND AVAILABILITY TO COMPLETE DATA
WIRING IN THIS AREA.
BUILDING 23R
SECTION 2E:
CONTRACTOR TO COORDINATE WITH VA FOR ROOM
CLOSURES AND AVAILABILITY TO COMPLETE DATA
WIRING IN THIS AREA.
BLDG. 02
BLDG. 01
BLDG. 01A
BLDG. 01S
BLDG. 12
BLDG. 23
BLDG. 23R
TR TOWER 1
T1-02
166 SF
TR TOWER 4
T4-02
160 SF
FEC
NEW SEMI-RECESSED FEC, TO MATCH
OR EXCEED EXISTING EXTINGUISHER IN
ABC RATING AND SIZE. SEE DET 4/A-604.
FEC
NEW SEMI-RECESSED FEC, TO MATCH
OR EXCEED EXISTING EXTINGUISHER IN
ABC RATING AND SIZE. SEE DET 4/A-604.
SPACE FOR NEW
DATA CENTER
23RA-100C
TR TOWER 1
TR TOWER 4
01W
0223R 01S
01A 01
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/0
/2
:1
:1 a m
B
IM
/5
-2
-7
V A
H u n t i n g to n E
H R
M /B
L D
G
L E
V E
L
.r v t 01SAS102
BUILDING 01S - LEVEL 02 - PHASING PLAN
01S
MA RB
100% CONSTRUCTION
DOCUMENTS
09/03/2025
581-22-700EHRM INFRASTRUCTURE
UPGRADES - HUNTINGTON
VA HUNTINGTON
1540 SPRING VALLEY DRIVE, HUNTINGTION, WV 25704-9300
KEY PLAN
LEGEND
PROJECT
NORTH
1" = 20'-0"
BUILDING 01S - LEVEL 02 - PHASING PLAN
09/03/20259/3/2025 086 OF 693
W
X
TO DEMOLISH
EXISTING DOOR TO REMAIN
EXISTING DOOR TO DEMOLISH
NEW DOOR
1 HR FIRE RATED WALL
SMOKE RATED WALL
NEW LIGHTS (SEE ELECTRICAL DETAILS)
2 HR FIRE RATED WALL
MOTION DETECTOR
SPRINKLER HEAD
X
T1-SB
TEMPORARY LOCATION OF EXHAUST.
MOVE INSIDE NEW TR ONCE FEASIBLE.
SEAL DOOR DURING
CONSTRUCTION
FOOTPRINT OF NEW
CONSTRUCTION
PREPARE AREA FOR
NEW CONSTRUCTION.
RESID.
FELL/STUD
2B199
202 SF
T1-SA
T1-S1
T1-S2
DEMO (E) VENEER BRICK THE
ENTIRE WIDTH AND HEIGHT OF
NEW TOWER
ANTE ROOM
ENTRY POINT
12 12
X
T1-SB
LINE OF
NEW CONSTRUCTION
WOMEN
2B196
46 SF
CORR
437 SF
ELEV
P - 1
87 SF
RESID.
FELL/STUD
2B199
202 SF
T1-SA
T1-S1
T1-S2
X
166 SF
TR TOWER 1
T1-02
01SA-105e
01SA-105e
T1-SB
T 1-
NEW
FLOORING
EXISTING
FLOORING
ELEV
P - 1
87 SF
RESID.
FELL/STUD
2B199
202 SF
WOMEN
2B196
46 SF
CORR
437 SF
DATA RACK
2' - 1" 11' - 8 3/4"
IN-03.01-8
T1-SA
T1-S1
T1-S2
E1C
02a
E1C 02a
02a
8" 8"
3' - 4" 5 1/2"
01S-AE451
MECH CHASE
01S-AE451
04a
1/
2"
1'
0"
8" 5 1/2"
01S-A-501
WALL TO WALL
EXPANSION
JOINT
03b
IN-01.02
6' - 7" 7' - 2 3/4"
13' - 9 3/4"
1' - 2"3" EXPANSION JOINT
IN-01.31
02a
02a
02a
X
T1-SB
ELEV
P - 1
87 SF
RESID.
FELL/STUD
2B199
202 SF
WOMEN
2B196
46 SF
CORR
437 SF
166 SF
TR TOWER 1
T1-02
T1-SA
T1-S1
T1-S2
EXPOSED
2' - 7"
3' - 11" 2' - 2"
2' - 2"
TR TOWER 1
01W
0223R 01S
01A 01
X
T1-SB
ELEV
P - 1
87 SF
WOMEN
2B196
46 SF
T1-SA
T1-S1
T1-S2
KEY AREA SHOWN
PROJECT
NORTH
( + ) PRESSURE
CONSTRUCTION ZONE, (--) PRESSURE
TEMPORARY ICRA BARRIER
TEMPORARY ICRA DOOR
CONSTRUCTION TACKY MAT
HEPA EQUIPPED EXHAUST
NFPA
TABLE 7.2.1.1 FIRE RESISTANCE RATING FOR TYPE I - 332 (HR)
COLUMNS
SUPPORTING MORE THAN ONE FLOOR 3 HOUR
SUPPORTING ONE FLOOR / ROOF ONLY 2 HOUR
BEAMS
SUPPORTING ONE FLOOR / ROOF ONLY 2 HOUR
FLOOR/CEILING ASSEMBLIES 2 HOUR
ROOF/CEILING ASSEMBLIES 1 1/2 HOUR
INTERIOR/EXTERIOR NONBEARING WALLS 0 HOUR
FIRE RATED REQUIREMENTS
FIRE RATING SCHEDULE
UL
REFERENCE
COLUMNS SUPPORTING ONE FLOOR
HOURLY
RATINGTYPE ELEMENT
I 2 HR UL X854
I COLUMNS SUPPORTING MORE
THAN ONE FLOOR
3 HR UL X854
COLUMNS SUPPORTING ROOFI 2 HR UL X854
FLOOR DECKSI 2 HR UL D779
FLOOR SUPPORTSI 2 HR UL P732
ROOF DECKSI 1 1/2 HR UL P732
ROOF SUPPORTSI 2 HR UL N732
FIRE RATED SCHEDULE
POLYETHYLENE SHEETING
HEPA EQUIPPED AIR FILTER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/0
/2
:5
:5 a m
B
IM
/5
-2
-7
V A
H u n t i n g to n E
H R
M /B
L D
G
S
T R
T O
W E
R .r v t
01SA-102
BUILDING 01S - LEVEL 02 - TOWER T1 -DEMO,
FLOOR PLANS & RCPS
01S
MA SR/RB
100% CONSTRUCTION
DOCUMENTS
09/03/2025
581-22-700EHRM INFRASTRUCTURE
UPGRADES - HUNTINGTON
VA HUNTINGTON
1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300
1. ALL PRODUCTS AND FINISHES SHALL MATCH EXISTING OR
ADJACENT EXISTING UNLESS OTHERWISE NOTED.
2. PATCH AND REPAIR WALLS, FLOORS AND CEILINGS
WHERE MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS
ARE DEMOLISHED.
3. PROTECT FINISHES IN ROOMS ADJACENT TO THE AREA OF
WORK AND PARTS THAT ARE NOT INCLUDED IN THE
SCOPE.
4. CONTRACTOR SHALL LEAVE FIRE RATING STAMP
UNPAINTED AND VISIBLE ON THE NEW INSTALLED FRT
PLYWOOD. SEE DETAIL 5/AE401.
5. REFER TO SHEET AS101 FOR ICRA REQUIREMENTS AND
DETAILS.
6. PATCH AND REPAIR CEILING, WALLS AND FLOORS AS
REQUIRED WHERE ICRA BARRIERS WILL BE CONSTRUCTED
AND REMOVED.
7. REFER TO SHEET A-602 FOR DOOR SCHEDULE.
GENERAL NOTES
KEY PLAN
KEY NOTES (THIS SHEET ONLY)
LEGEND
PROJECT
NORTH
PROJECT
NORTH
PROJECT
NORTH
PROJECT
NORTH
ICRA LEGEND
PROJECT
NORTH
PROJECT
NORTH
PROJECT
NORTH
PROJECT
NORTH
1/4" = 1'-0"
LEVEL 02 - TR TOWER 1 - DEMO FLOOR PLAN
1/4" = 1'-0"
LEVEL 02 - TR TOWER 1 - DEMO RCP
1/4" = 1'-0"
RM T1-02 - FLOOR PLAN
1/4" = 1'-0"
RM T1-02 - RCP
TYPE IV BARRIER WILL TEMPORARILY
BLOCK ACCESS TO RM 2B196.
COORDINATE WORK WITH COR.
10 INSTALL TEMPORARY 1 HR CONSTRUCTION ICRA BARRIER TO
SEPARATE CONSTRUCTION AREA FROM OCCUPIED SPACE.
11 INSTALL FIRE RESISTANT TEMPORARY SELF-CLOSING DOOR,
SOLID CORE WOOD IN STEEL FRAME, PAINTED, AT OPENING
AND MATCH RATING OF ICRA BARRIER, TYPICAL.
12 PLACE TACKY MATS AT ENTRANCE AND EXIT OF
CONSTRUCTION AREA, MINIMUM SIZE 24"x36", TYPICAL.
13 INSTALL POLYETHYLENE SHEETING TO ISOLATE
CONSTRUCTION ZONE. TAPE AND SEAL ALONG EDGES, AND
ANY AREAS WHERE POTENTIAL DUST MAY BE EXPOSED
OUTSIDE OF CONSTRUCTION AREA.
1 DEMOLISH PORTION OF EXISTING WALL. PREPARE FOR NEW
DOOR/FRAME.
2 DEMOLISH EXISTING WINDOW/FRAME.
3 INSTALL NEW DOOR/FRAME.
4 CONSTRUCT NEW WALL.
5 INFILL WALL.
6 CONSTRUCT NEW FLOOR.
7 APPLY ANTI-STATIC COATING TO EXPOSED FLOOR. PROVIDE
VINYL REDUCER STRIP AT EXISTING FLOORING TRANSITION.
8 INSTALL NEW RESILIENT RUBBER BASE AT ROOM PERIMETER
WITH SEALANT AT THE BOTTOM.
9 INSTALL FRT PLYWOOD OVER WALLS AS NEEDED PER DETAIL
3/AE401, TYPICAL.
ICRA KEYNOTES
ICRA CLASS IV LEGEND
ICRA CLASS II LEGEND
09/03/20259/3/2025 087 OF 693
C
W
X
LXS
TO DEMOLISH
EXISTING DOOR TO REMAIN
EXISTING DOOR TO DEMOLISH
NEW DOOR
1 HR FIRE RATED WALL
SMOKE RATED WALL
NEW LIGHTS (SEE ELECTRICAL DETAILS)
2 HR FIRE RATED WALL
MOTION DETECTOR
SPRINKLER HEAD
O P Q
CORRIDOR
C2-11
696 SF
CORRIDOR
C2-41
300 SF
MECH
2B155
2067 SF
TELE. CLO.
2B155b
35 SFFOOTPRINT OF NEW
CONSTRUCTION
PREPARE AREA FOR
NEW CONSTRUCTION.
SEAL WINDOW DURING
CONSTRUCTION
SEAL WINDOW DURING
CONSTRUCTION
TEMPORARY LOCATION OF EXHAUST.
MOVE INSIDE NEW TR ONCE FEASIBLE.
17' - 7 1/4"
/2
T4-S1
ANTE ROOM
T4-SA T4-SB
3'
O P Q
CORRIDOR
C2-11
696 SF
CORRIDOR
C2-41
300 SF
MECH
2B155
2067 SF
TELE. CLO.
2B155b
35 SF
LINE OF NEW
CONSTRUCTION
T4-S1
T4-SA T4-SB
O P Q
160 SF
TR TOWER 4
T4-02
01SA-105f
01SA-105f
01SA-105d1
01SA-105d
01SA-105d 3
15' - 4 1/2" CLEARANCE
1/ 2"
C
LE
A R
A N
C E
3/
4"
8' - 8 1/2" 17' - 1 1/4"
DATA RACK
T 4-
NEW
FLOORING
EXISTING
FLOORING
E1C
E1C
E1C
IN-03.01-9
WALL TO WALL
EXPANSION JOINT
WALL TO WALL
EXPANSION JOINT
1/
2"
3/ 4"
3'
9 1/4" 8 3/4"
2' - 8 1/4"
8 3/4" 9 1/4"
1' - 6"
T4-S1
04a
04a
02a
T4-SA T4-SB
IN-01.31
M
IN
O P Q
CORRIDOR
C2-11
696 SF
160 SF
TR TOWER 4
T4-02CORRIDOR
C2-41
300 SF
MECH
2B155
2067 SF
TELE. CLO.
2B155b
35 SFEXPOSED
AC UNIT
T4-S1
1' - 10"
1' - 10"1' - 10"
T4-SA T4-SB
TR TOWER 4
01W
0223R 01S
01A 01
KEY AREA SHOWN
PROJECT
NORTH
( + ) PRESSURE
CONSTRUCTION ZONE, (--) PRESSURE
TEMPORARY ICRA BARRIER
TEMPORARY ICRA DOOR
CONSTRUCTION TACKY MAT
HEPA EQUIPPED EXHAUST
NFPA
TABLE 7.2.1.1 FIRE RESISTANCE RATING FOR TYPE I - 332 (HR)
COLUMNS
SUPPORTING MORE THAN ONE FLOOR 3 HOUR
SUPPORTING ONE FLOOR / ROOF ONLY 2 HOUR
BEAMS
SUPPORTING ONE FLOOR / ROOF ONLY 2 HOUR
FLOOR/CEILING ASSEMBLIES 2 HOUR
ROOF/CEILING ASSEMBLIES 1 1/2 HOUR
INTERIOR/EXTERIOR NONBEARING WALLS 0 HOUR
FIRE RATED REQUIREMENTS
FIRE RATING SCHEDULE
UL
REFERENCE
COLUMNS SUPPORTING ONE FLOOR
HOURLY
RATINGTYPE ELEMENT
I 2 HR UL X854
I COLUMNS SUPPORTING MORE
THAN ONE FLOOR
3 HR UL X854
COLUMNS SUPPORTING ROOFI 2 HR UL X854
FLOOR DECKSI 2 HR UL D779
FLOOR SUPPORTSI 2 HR UL P732
ROOF DECKSI 1 1/2 HR UL P732
ROOF SUPPORTSI 2 HR UL N732
FIRE RATED SCHEDULE
POLYETHYLENE SHEETING
HEPA EQUIPPED AIR FILTER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/0
/2
:5
:0 a m
B
IM
/5
-2
-7
V A
H u n t i n g to n E
H R
M /B
L D
G
S
T R
T O
W E
R .r v t
01SA-202
BUILDING 01S - LEVEL 02 - TOWER T4 -DEMO,
FLOOR PLANS & RCPS
01S
MA SR/RB
100% CONSTRUCTION
DOCUMENTS
09/03/2025
581-22-700EHRM INFRASTRUCTURE
UPGRADES - HUNTINGTON
VA HUNTINGTON
1540 SPRING VALLEY DRIVE, HUNTINGTON, WV 25704-9300
1. ALL PRODUCTS AND FINISHES SHALL MATCH EXISTING OR
ADJACENT EXISTING UNLESS OTHERWISE NOTED.
2. PATCH AND REPAIR WALLS, FLOORS AND CEILINGS
WHERE MECHANICAL, PLUMBING, AND ELECTRICAL ITEMS
ARE DEMOLISHED.
3. PROTECT FINISHES IN ROOMS ADJACENT TO THE AREA OF
WORK AND PARTS THAT ARE NOT INCLUDED IN THE
SCOPE.
4. CONTRACTOR SHALL LEAVE FIRE RATING STAMP
UNPAINTED AND VISIBLE ON THE NEW INSTALLED FRT
PLYWOOD. SEE DETAIL 5/AE401.
5. REFER TO SHEET AS101 FOR ICRA REQUIREMENTS AND
DETAILS.
6. PATCH AND REPAIR CEILING, WALLS AND FLOORS AS
REQUIRED WHERE ICRA BARRIERS WILL BE CONSTRUCTED
AND REMOVED.
7. REFER TO SHEET A-602 FOR DOOR SCHEDULE.
GENERAL NOTES
KEY PLAN
KEY NOTES (THIS SHEET ONLY)
LEGEND
ICRA LEGEND
1/4" = 1'-0"
LEVEL 02 - TR TOWER 4 - DEMO FLOOR PLAN
1/4" = 1'-0"
LEVEL 02 - TR TOWER 4 - DEMO RCP
1/4" = 1'-0"
RM T4-02 - FLOOR PLAN
1/4" = 1'-0"
RM T4-02 - RCP
PROJECT
NORTH
PROJECT
NORTH
PROJECT
NORTH
PROJECT
NORTH
8 INSTALL TEMPORARY 1 HR CONSTRUCTION ICRA BARRIER TO
SEPARATE CONSTRUCTION AREA FROM OCCUPIED SPACE.
9 INSTALL FIRE RESISTANT TEMPORARY SELF-CLOSING DOOR,
SOLID CORE WOOD IN STEEL FRAME, PAINTED, AT OPENING
AND MATCH RATING OF ICRA BARRIER, TYPICAL.
10 PLACE TACKY MATS AT ENTRANCE AND EXIT OF
CONSTRUCTION AREA, MINIMUM SIZE 24"x36", TYPICAL.
1 DEMOLISH PORTION OF EXISTING WALL. PREPARE FOR NEW
DOOR/FRAME.
2 INSTALL NEW DOOR/FRAME.
3 CONSTRUCT NEW WALL.
4 CONSTRUCT NEW FLOOR.
5 APPLY ANTI-STATIC COATING TO EXPOSED FLOOR. PROVIDE
VINYL REDUCER STRIP AT EXISTING FLOORING TRANSITION.
6 INSTALL NEW RESILIENT RUBBER BASE AT ROOM PERIMETER
WITH SEALANT AT THE BOTTOM.
7 INSTALL FRT PLYWOOD OVER WALLS AS NEEDED PER DETAIL
3/AE401, TYPICAL.
ICRA KEYNOTES
ICRA CLASS IV LEGEND
ICRA CLASS II LEGEND
09/03/20259/3/2025 088 OF 693
ICRA CLASS III
ICRA CLASS IV
ICRA CLASS II
FIRE EXTINGUISHER CABINETFEC
FIRE EXTINGUISHERFE
BUILDING BOUNDARY LINE
2 HR FIRE RATED WALL
1 HR FIRE RATED WALL
SMOKE RATED WALL
KEY AREA SHOWN
PROJECT
NORTH
L M N O P Q R S T U V W X Y Z
A14A15A16
BLDG. 12
246 SF
STAFF
BREAKROOM
3C172
82 SF
COPIER
3C130
118 SF
EXAM
3C173
122 SF
EXAM
3C174
46 SF
ELE
3C129
121 SF
EXAM
3C12…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .