S02 - ATT 27 - 581-22-700 - Asbestos locations.xlsx

XLSX spreadsheet 25 KB Posted

Attached to
EHRM Huntington VAMC 581-22-700 Construct Infrastructure Upgrades Federal contract opportunity
Solicitation number
36C77626R0025
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This is an asbestos locations inventory spreadsheet documenting suspected and confirmed asbestos-containing materials (ACM) and presumed asbestos-containing materials (PACM) at the Hershel "Woody" Williams Veteran Affairs Medical Center in Huntington, West Virginia. The spreadsheet identifies asbestos locations across Building 1, Building 1A, and Building 1W, cataloging material types, sample IDs, locations, chrysotile content percentages where tested, AHERA categories, condition ratings, and quantities.

The inventory documents both sampled and unsampled materials, including vinyl floor tiles and mastics with confirmed 2-10% chrysotile content or positive results, asphalt roof shingles (10,000 SF in Building 1 and 8,000 SF in Building 1A), pipe insulation, fire doors, elevator brake shoes, and miscellaneous packings and gaskets. Notable entries include 16,949 SF of presumed asbestos debris in the crawlspace under concrete and concrete flooring, and 25,000 SF of black mastic under brown mottled vinyl floor tiles in Building 1W. All materials are rated in good condition or significantly damaged, with condition ratings of 5 assigned to most items. This inventory directly supports the EHRM Huntington VAMC Infrastructure Upgrades project (Solicitation 36C77626R0025), a $20-50 million Service-Disabled Veteran-Owned Small Business set-aside requiring contractors to address asbestos abatement and removal as part of the 690-calendar-day construction scope.

View the file

Other files for this federal contract opportunity

Other files attached to EHRM Huntington VAMC 581-22-700 Construct Infrastructure Upgrades, newest first.
File Type Posted
S06 - 36C77626R0025 0008.pdf PDF
S06 - Amendment 0008 - ATT 3 - Civil OSP Redesign-signed.pdf PDF
S06 - Amendment 0008 - ATT 7 - 02EP100B - ELECTRICAL 20260413.pdf PDF
S06 - Amendment 0008 - ATT 8 - 260508 - Sheet 01S-AE452 TR Tower 4 Wall sections update.pdf PDF
S06 - Amendment 0008 - ATT 12 - Environmental Report Huntington WV.pdf PDF
S06 - Amendment 0008 - ATT 13 - Hot Tapping Permit.pdf PDF
S06 - Amendment 0008 - ATT 1 - TechQuestionsVAresponses Final Set - Huntington EHRM IU.pdf PDF
S06 - Amendment 0008 - ATT 10 - 260508 - Sheet AD103-1B Data Center Phase 1B Demo Roof update.pdf PDF
S06 - Amendment 0008 - ATT 11 - Burn Permit.pdf PDF
S06 - Amendment 0008 - ATT 14 - Energized Electrical Work Permit.pdf PDF
S06 - Amendment 0008 - ATT 4 - Structural Set 04-21-2026.pdf PDF
S06 - 36C77626R0025 0007.pdf PDF
S06 - Amendment 0007 - ATT 1 - TechQuestionsVAresponses Partial 4 - Huntington EHRM IU.pdf PDF
S06 - Amendment 0007 - ATT 5 - Appendix A - PFC FPT.pdf PDF
S06 - 36C77626R0025 0006.pdf PDF
S06 - Amendment 0006 - ATT 1 - TechQuestionsVAresponses Partial 3 - Huntington EHRM IU.pdf PDF
S06 - 36C77626R0025 0005.pdf PDF
S06 - Amendment 0004 - ATT 2 - FAR 52.222-90 ADDRESSING DEI DISCRIMINATION BY FEDERAL CONTRACTORS - APR 2026.pdf PDF
S06 - Amendment 0004 - ATT 1 - TechQuestionsVAresponses Partial 2 - Huntington EHRM IU.pdf PDF
S06 - 36C77626R0025 0004.pdf PDF
S06 - Amendment 0003 - ATT 2 - TechQuestionsVAresponses Partial - Huntington EHRM IU.pdf PDF
S06 - 36C77626R0025 0003.pdf PDF
S06 - 36C77626R0025 0002.pdf PDF
S06 - Amendment 0001 - ATT 1 - Site Visit In-Sheet - Huntington EHRM IU.pdf PDF
S06 - 36C77626R0025 0001.pdf PDF
S02 - ATT 10 - 581-22-700 - 100 Drawings Part-8 of 24.pdf PDF
S02 - ATT 14 - 581-22-700 - 100 Drawings Part-12 of 24.pdf PDF
S02 - ATT 28 - 581-22-700 - FLS Compliance Letter.pdf PDF
S02 - 36C77626R0025.pdf PDF
S02 - ATT 1 - 581-22-700 - 100 Specifications Part-1 of 2.pdf PDF
S02 - ATT 2 - 581-22-700 - 100 Specifications Part-2 of 2.pdf PDF
S02 - ATT 9 - 581-22-700 - 100 Drawings Part-7 of 24.pdf PDF
S02 - ATT 11 - 581-22-700 - 100 Drawings Part-9 of 24.pdf PDF
S02 - ATT 15 - 581-22-700 - 100 Drawings Part-13 of 24.pdf PDF
S02 - ATT 18 - 581-22-700 - 100 Drawings Part-16 of 24.pdf PDF
S02 - ATT 20 - 581-22-700 - 100 Drawings Part-18 of 24.pdf PDF
S02 - ATT 23 - 581-22-700 - 100 Drawings Part-21 of 24.pdf PDF
S02 - ATT 24 - 581-22-700 - 100 Drawings Part-22 of 24.pdf PDF
S02 - ATT 30 - 581-22-700 - 100 Commissioning Plan.pdf PDF
S02 - ATT 3 - 581-22-700 - 100 Drawings Part-1 of 24.pdf PDF
S02 - ATT 4 - 581-22-700 - 100 Drawings Part-2 of 24.pdf PDF
S02 - ATT 5 - 581-22-700 - 100 Drawings Part-3 of 24.pdf PDF
S02 - ATT 6 - 581-22-700 - 100 Drawings Part-4 of 24.pdf PDF
S02 - ATT 7 - 581-22-700 - 100 Drawings Part-5 of 24.pdf PDF
S02 - ATT 17 - 581-22-700 - 100 Drawings Part-15 of 24.pdf PDF
S02 - ATT 19 - 581-22-700 - 100 Drawings Part-17 of 24.pdf PDF
S02 - ATT 22 - 581-22-700 - 100 Drawings Part-20 of 24.pdf PDF
S02 - ATT 26 - 581-22-700 - 100 Drawings Part-24 of 24.pdf PDF
S02 - ATT 33 - WD - WV20260048 - 01-02-2026.pdf PDF
S02 - ATT 35 - Site Visit Information - Huntington EHRM IU.pdf PDF
Show all 50

EHRM Huntington VAMC 581-22-700 Construct Infrastructure Upgrades has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Material TypeSample IDSample LocationContentTypeAHERA CategoryConditionQuantityNotesLocation
M - Asphalt Roof ShingleNot SampledN/APOSN/A5Good10,000 SFExterior Roof Shingles Assumed ACMBuilding 1
M - Fire DoorsNot SampledN/APOSN/A5GoodNot QuantifiedMetal Fire Doors Assumed ACMBuilding 1
M - Mastic Coating on SurfaceNot SampledN/APOSN/A5GoodN/AMiscellaneous Wall/Ceiling Mastics are Assumed ACMBuilding 1
M - Elevator Brake ShoesNot SampledN/APOSN/A5Good2 Elevator CabsElevator Brake Systems are Assumed to have ACM Brake PadsBuilding 1
M - Other, Not Listed (add description)Not SampledN/APOSN/A5GoodN/AMiscellaneous Packings and Gaskets are Assumed to be ACMBuilding 1
T - Pipe Insulation (Fittings, Elbows, Runs)Not SampledN/APOSN/A5GoodN/APipe Joint Insulation Compounds are Assumed to be Asbestos-Containing Based on prior Sample DataBuilding 1
T - Pipe Insulation (Corrugated Air-Cell, Block, etc.)Not SampledN/APOSN/A5GoodN/APipe Insulation is Assumed to be Asbestos-Containing Based on Prior Sample DataBuilding 1
M - Mastic Coating on SurfaceNot SampledN/APOSN/A5Good1,000 SFPresumed ACM Floor Tile Mastics (including the non-acm Floor Tiles) in 2nd Floor Rear HallwayBuilding 1
T - Pipe Insulation (Corrugated Air-Cell, Block, etc.)Not SampledN/APOSN/A1Sig Damaged16,949 SFPresumed Asbestos Debris in Floor of Crawlspace Encased Under Concrete and Presumed ACM PI/PJIC Remnant Debris found within a Trench under the Ground Floor FlooringBuilding 1
M - Vinyl Floor TileHuntington-102909-4-4-295Building 1, 4th Floor, Hallway2-10%Chrysotile5Good250 SF9x9 grey w/ white streaks VFTBuilding 1
M - Vinyl Floor TileHuntington-102909-4-4-296Building 1, 4th Floor, HallwayPOSChrysotile5Good250 SF9x9 grey w/ white streaks VFTBuilding 1
M - Vinyl Floor TileHuntington-102909-4-4-297Building 1, 4th Floor, Hallway2-10%Chrysotile5Good250 SF9x9 white mottled VFTBuilding 1
M - Floor Tile MasticHuntington-102909-4-4-297Building 1, 4th Floor, Hallway2-10%Chrysotile5Good250 SFblack mastic assoc. w/ 9x9 white mottled VFTBuilding 1
M - Vinyl Floor TileHuntington-102909-4-4-298Building 1, 4th Floor, HallwayPOSChrysotile5Good250 SF9x9 white mottled VFTBuilding 1
M - Floor Tile MasticHuntington-102909-4-4-298Building 1, 4th Floor, HallwayPOSChrysotile5Good250 SFblack mastic assoc. w/ 9x9 white mottled VFTBuilding 1
M - Other, Not Listed (add description)Huntington-102709-1A-1-191Ground Level, Stairwell 102-10%Chrysotile5Good1,000 SFLayer 1 - Brown Mottled Vinyl Stair TreadBuilding 1A
M - Other, Not Listed (add description)Huntington-102709-1A-1-192Ground Level, Stairwell 10POSChrysotile5Good1,000 SFLayer 1 - Brown Mottled Vinyl Stair TreadBuilding 1A
M - Vinyl Floor TileHuntington-102709-1A-1-193Ground Level, Stairwell 102-10%Chrysotile5Good100 SFLayer 1 - 12" x 12" Brown Floor Tile with White StreaksBuilding 1A
M - Vinyl Floor TileHuntington-102709-1A-1-194Ground Level, Stairwell 10POSChrysotile5Good100 SFLayer 1 - 12" x 12" Brown Floor Tile with White StreaksBuilding 1A
M - Asphalt Roof ShinglePACM - Not SampledN/APOSN/A5Good8,000 SFExterior Roofing MaterialsBuilding 1A
M - Mastic Coating on SurfacePACM - Not SampledN/APOSN/A5GoodN/AMiscellaneous Wall/Ceiling MasticsBuilding 1A
M - Fire DoorsPACM - Not SampledN/APOSN/A5GoodN/AFire DoorsBuilding 1A
M - Elevator Brake ShoesPACM - Not SampledN/APOSN/A5GoodOne Elevator CabBrake Systems for ElevatorsBuilding 1A
M - Other, Not Listed (add description)PACM - Not SampledN/APOSN/A5GoodN/AMiscellaneous Packings and GasketsBuilding 1A
M - Vinyl Floor TilePACM - Not SampledN/APOSN/A5GoodN/AMulti-colored vinyl floor tiles (12”x12”) being utilized for directional purposes (i.e., arrows, etc.)Building 1A
M - Floor Tile MasticPACM - Not SampledN/APOSN/A5GoodN/AMastic assoc. w/ multi-colored vinyl floor tiles (12”x12”) and the associated black mastic being utilized for directional purposes (i.e., arrows, etc.)Building 1A
T - Pipe Insulation (Fittings, Elbows, Runs)PACM - Not SampledN/APOSN/A5GoodN/APipe Joint Insulation Compounds are presumed to be Asbestos-Containing Based on Prior Sampling DataBuilding 1A
T - Pipe Insulation (Corrugated Air-Cell, Block, etc.)PACM - Not SampledN/APOSN/A5GoodN/APipe Insulation is Presumed to be Asbestos-Containing Based on Prior Sampling DataBuilding 1A
T - Pipe Insulation (Fittings, Elbows, Runs)PACM - Not SampledN/APOSN/A5GoodN/AThis remnant asbestos material is assumed to exist within the crawlspace of the building.Building 1A
M - Mastic Coating on SurfaceHuntington-0100109-1W-3-44Hallway Outside Room 3C1502-10%Chrysotile5Good25,000 SFLayer 2 - Black Mastic Under 12" x 12" Brown Mottled Vinyl Floor TileBuilding 1W
M - Mastic Coating on SurfaceHuntington-0100109-1W-3-45Hallway Outside Room 3C158POSN/A5GoodN/ALayer 2 - Black Mastic Under 12" x 12" Brown Mottled Vinyl Floor TileBuilding 1W
M - Carpet Glue/MasticHuntington-0100109-1W-3-48Room 3C143<1.0%ChrysotileN/AGoodN/AYellow Carpet MasticBuilding 1W
M - Vinyl Floor TileHuntington-0100109-1W-G-80Room GC1362-10%Chrysotile5Good250 SFLayer 1 - 12" x 12" Beige Vinyl Floor Tile with Brown StreaksBuilding 1W
M - Vinyl Floor TileHuntington-0100109-1W-G-81Room GC136POSN/A5GoodN/ALayer 1 - 12" x 12" Beige Vinyl Floor Tile with Brown StreaksBuilding 1W
M - Fire DoorsNot SampledN/APOSN/A5GoodNot QuantifiedFire Doors Assumed to be ACMBuilding 1W
T - Pipe Insulation (Corrugated Air-Cell, Block, etc.)Not SampledN/APOSN/A1Significantly Damaged6,494 SFAsbestos Debris in Floor of Crawlspace Encased Under ConcreteBuilding 1W
M - Asphalt Roof ShingleNot SampledN/APOSN/A5Good10,000 SFExterior Roofing MaterialsBuilding 1W
M - Mastic Coating on SurfaceNot SampledN/APOSN/A5GoodNot QuantifiedMiscellaneous Wall/Ceiling MasticsBuilding 1W
M - Elevator Brake ShoesNot SampledN/APOSN/A5GoodTwo Elevator CabsElevator Brake Systems are Assumed to Contain Asbestos PadsBuilding 1W
M - Other, Not Listed (add description)Not SampledN/APOSN/A5GoodNot QuantifiedMiscellaneous Packings and GasketsBuilding 1W
T - Pipe Insulation (Fittings, Elbows, Runs)Not SampledN/APOSN/A5GoodNot QuantifiedPipe Joint Insulation CompoundsBuilding 1W
T - Pipe Insulation (Corrugated Air-Cell, Block, etc.)Not SampledN/APOSN/A5GoodNot QuantifiedPipe InsulationBuilding 1W
M - Fire DoorsPACM - Not SampledN/APOSND5GoodNot QuantifiedFire Doors are Assumed to be Asbestos-ContainingBuilding 2
S - Other, Not Listed (add description)PACM - Not SampledN/APOSND5Damaged875 SFAluminum Roof Coating is Presumed to be Asbestos-ContainingBuilding 2
M - Mastic Coating on SurfacePACM - Not SampledN/APOSND5GoodNot QuantifiedMiscellaneous Wall/Ceiling Mastics are Presumed to be Asbestos-ContainingBuilding 2
M - Elevator Brake ShoesPACM - Not SampledN/APOSND5Good1 Freight Elevator CabBrake Systems for Elevators are Presumed to have Asbestos-Containing Brqake PadsBuilding 2
M - Other, Not Listed (add description)PACM - Not SampledN/APOSND5GoodNot QuantifiedMiscellaneous Packings and Gaskets are Presumed to be Asbestos-ContainingBuilding 2
M - Floor Tile MasticPACM - Not SampledN/APOSND5Good5,648 SFBlack Floor Tile Mastic was Presumed to be Asbestos-Containing Based on Previous Sample DataBuilding 2
T - Pipe Insulation (Fittings, Elbows, Runs)PACM - Not SampledN/APOSND5GoodNot QuantifiedPreviously Identified in the Facility, but not Observed by EFI. Remnants may still exist in Inaccessible AreasBuilding 2
T - Pipe Insulation (Corrugated Air-Cell, Block, etc.)PACM - Not SampledN/APOSND5GoodNot QuantifiedPreviously Identified in the Facility, but not Observed by EFI. Remnants may still exist in Inaccessible AreasBuilding 2
M - Vinyl Floor TilePACM - Not SampledN/APOSND5Good5,648 SFVFT was Presumed to be Asbestos-Containing Based on Previous Sample DataBuilding 2
S - Other, Not Listed (add description)PACM - Not SampledN/APOSND5Damaged875 SFAluminum Roof Coating is Presumed to be Asbestos-Containing2-3 Tunnels
M - Mastic Coating on SurfacePACM - Not SampledN/APOSND5GoodNot QuantifiedMiscellaneous Wall/Ceiling Mastics are Presumed to be Asbestos-Containing2-3 Tunnels
M - Elevator Brake ShoesPACM - Not SampledN/APOSND5Good1 Freight Elevator CabBrake Systems for Elevators are Presumed to have Asbestos-Containing Brake PadsBuilding 3
M - Other, Not Listed (add description)PACM - Not SampledN/APOSND5GoodNot QuantifiedMiscellaneous Packings and Gaskets are Presumed to be Asbestos-ContainingBuilding 3
M - Floor Tile MasticPACM - Not SampledN/APOSND5Good5,648 SFBlack Floor Tile Mastic was Presumed to be Asbestos-Containing Based on Previous Sample DataBuilding 3
T - Pipe Insulation (Fittings, Elbows, Runs)PACM - Not SampledN/APOSND5GoodNot QuantifiedPreviously Identified in the Facility, but not Observed by EFI. Remnants may still exist in Inaccessible AreasBuilding 3
T - Pipe Insulation (Corrugated Air-Cell, Block, etc.)PACM - Not SampledN/APOSND5GoodNot QuantifiedPreviously Identified in the Facility, but not Observed by EFI. Remnants may still exist in Inaccessible AreasBuilding 4
M - Vinyl Floor TilePACM - Not SampledN/APOSND5Good5,648 SFVFT was Presumed to be Asbestos-Containing Based on Previous Sample DataBuilding 4
T - Pipe Insulation (Fittings, Elbows, Runs)NATunnel Between the Maintenance Building (Building #2) and the Boiler Plant Building (Building #3)POSNot Determined1Significantly DamagedNot QuantifiedPipe Joint Insulation Compounds (PJIC) are presumed (based on previous reports and a visual inspection) to exist in various locations throughout the tunnel in pipe chases, above ceiling plenums and other in-accessible areas (i.e., chases, above ceilings, etc.) on active and abandoned pipe systems. These materials were identified to be in a significantly damaged condition.Building 4
T - Pipe Insulation (Corrugated Air-Cell, Block, etc.)NATunnel Between the Maintenance Building (Building #2) and the Boiler Plant Building (Building #3)POSNot Determined1Significantly DamagedNot QuantifiedPipe Insulation (PI) is presumed (based on previous asbestos reports and a visual inspection) to exist in various locations throughout the tunnel in pipe chases, above ceiling plenums and other in-accessible areas (i.e., chases, above ceilings, etc.) on active and abandoned pipe systems. These materials were identified to be in a significantly damaged condition.Building 4
M - Built-up RoofingPACM - Not SampledN/APOSND5Good5,000 SFRoof Surfacing Material is Presumed to be Asbestos-ContainingBuilding 4
M - Mastic Coating on SurfacePACM - Not SampledN/APOSND5GoodNot QuantifiedMiscellaneous Wall/Ceiling Mastics are Assumed to be Asbestos-ContainingBuilding 4
M - Fire DoorsPACM - Not SampledN/APOSND5GoodNot QuantifiedFire Doors Throughout the Facility are Presumed to be Asbestos-ContainingBuilding 4
M - Other, Not Listed (add description)PACM - Not SampledN/APOSND5GoodNot QuantifiedMiscellaneous Packings and Gaskets are Presumed to be Asbestos-ContainingBuilding 4
M - Asphalt Roof ShinglePACM - Not SampledN/APOSND5Good10,00 SFRoof Shingles on Main Building are Presumed to be Asbestos-ContainingBuilding 4
M - Mastic Coating on SurfacePACM - Not SampledN/APOSND5GoodNot QuantifiedMiscellaneous Walll and Ceiling Mastics are Presumed to be Asbestos-ContainingBuilding 4
M - Fire DoorsPACM - Not SampledN/APOSND5GoodNot QuantifiedFire Doors Throughout the Facility are Presumed to be Asbestos-ContainingBuilding 4
M - Elevator Brake ShoesPACM - Not SampledN/APOSND5GoodOne Elevator CabBrake Systems for Elevators are Presumed to have Asbestos-Containing Brqake PadsBuilding 5
M - Other, Not Listed (add description)PACM - Not SampledN/APOSND5GoodNot QuantifiedMiscellaneous Packings and Gaskets are Presumed to be Asbestos-ContainingBuilding 6
M - Floor Tile MasticPACM - Not SampledN/APOSND5Good17,000 SFThe Black Floor Tile Mastic is Presumed to be Asbestos-Containing Based on Prior Sample DataBuilding 6
M - Vinyl Floor TilePACM - Not SampledN/APOSND5Good20,000 SFVinyl Floor Tiles were Presumed to be Asbestos-Containing Based on Prior Sampling DataBuilding 6
M - Joint CompoundPACM - Not SampledN/APOSND5GoodNot QuantifiedJoint Compound in one office and an adjacent wall in the Southwest Basement was Presumed to be Asbestos-Containing Based on Prior Sampling DataBuilding 6
T - Pipe Insulation (Fittings, Elbows, Runs)PACM - Not SampledN/APOSND5GoodNot QuantifiedPreviously Identified in the facility, and is presumed to exist in various locations throughout the buildingBuilding 6
T - Pipe Insulation (Corrugated Air-Cell, Block, etc.)PACM - Not SampledN/APOSND5GoodNot QuantifiedPreviously Identified in the facility, and is presumed to exist in various locations throughout the buildingBuilding 6
M - Other, Not Listed (add description)PACM - Not SampledN/APOSND1Sig. DamagedNot QuantifiedAssumed to exist in the Inaccessible Ground Level Debris PitBuilding 6
M - Asphalt Roof ShinglePACM - Not SampledN/APOSND5Good4,000 SFRoofing Shingles and Associated Materials are Presumed to be Asbestos-ContainingBuilding 6
M - Asphalt Roof ShinglePACM - Not SampledN/APOSND5Good3,000 SFRoof Shingles on Building are Presumed to be Asbestos-ContainingBuilding 6
M - Mastic Coating on SurfacePACM - Not SampledN/APOSND5GoodNot QuantifiedMiscellaneous Wall and Ceiling Mastics are Presumed to be Asbestos-ContainingBuilding 6
M - Fire DoorsPACM - Not SampledN/APOSND5GoodNot QuantifiedFire Doors Throughout the Facility are Presumed to be Asbestos-ContainingBuilding 6
M - Other, Not Listed (add description)PACM - Not SampledN/APOSND5GoodNot QuantifiedMiscellaneous Packings and Gaskets are Presumed to be Asbestos-ContainingBuilding 7
M - Vinyl Floor TilePACM - Not SampledN/APOSND5Good600 SFThe Floor Tiles are Presumed to be Asbestos-Containing Based on Prior Sample DataBuilding 7
M - Floor Tile MasticPACM - Not SampledN/APOSND5Good600 SFThe Black Floor Tile Mastic is Presumed to be Asbestos-Containing Based on Prior Sampling DataBuilding 7
M - Floor Tile MasticPACM - Not SampledN/APOSND5Good100 SFThis Black Floor Tile Mastic is Presumed to be Asbestos-Containing Based on Prior Sampling DataBuilding 7
M - Vinyl Floor TilePACM - Not SampledN/APOSND5Good200 SFThe Floor Tiles are Presumed to be Asbestos-Containing Based on Prior Sample DataBuilding 7
M - Cove Base MasticPACM - Not SampledN/APOSND5Good160 LFThe Cove Base Mastic is Presumed to be Asbestos-Containing Based on Prior Sample DataBuilding 7
T - Pipe Insulation (Fittings, Elbows, Runs)PACM - Not SampledN/APOSND5GoodNot QuantifiedPreviously Identified in the facility, and is presumed to exist in various locations throughout the buildingBuilding 7
T - Pipe Insulation (Corrugated Air-Cell, Block, etc.)PACM - Not SampledN/APOSND5GoodNot QuantifiedPreviously Identified in the facility, and is presumed to exist in various locations throughout the buildingBuilding 7
M - Asphalt Roof ShinglePACM - Not SampledN/APOSND5Good2,000 SFRoof Shingles on Building are Presumed to be Asbestos-ContainingBuilding 7
M - Mastic Coating on SurfacePACM - Not SampledN/APOSND5GoodNot QuantifiedMiscellaneous Wall and Ceiling Mastics are Presumed to be Asbestos-ContainingBuilding 7
M - Fire DoorsPACM - Not SampledN/APOSND5GoodNot QuantifiedFire Doors Throughout the Facility are Presumed to be Asbestos-ContainingBuilding 8
M - Other, Not Listed (add description)PACM - Not SampledN/APOSND5GoodNot QuantifiedMiscellaneous Packings and Gaskets are Presumed to be Asbestos-ContainingBuilding 8
M - Floor Tile MasticPACM - Not SampledN/APOSND5Good1,100 SFThe Black Floor Tile Mastic is Presumed to be Asbestos-Containing Based on Prior Sample DataBuilding 8
T - Mastic Coating on Thermal Pipe Jacket CoverPACM - Not SampledN/APOSND5GoodNot QuantifiedPipe Insulation Mastic is Presumed to be Asbestos-Containing Based on Prior Sampling DataBuilding 8
T - Pipe Insulation (Fittings, Elbows, Runs)PACM - Not SampledN/APOSND5GoodNot QuantifiedPreviously Identified in the facility, and is presumed to exist in various locations throughout the buildingBuilding 8
T - Pipe Insulation (Corrugated Air-Cell, Block, etc.)PACM - Not SampledN/APOSND5GoodNot QuantifiedPreviously Identified in the facility, and is presumed to exist in various locations throughout the buildingBuilding 8
T - Pipe Insulation (Corrugated Air-Cell, Block, etc.)PACM - Not SampledN/APOSND1DamagedNot QuantifiedResidual Pipe Insulation is Presumed to be Asbestos-Containing Based on Prior Sampling DataBuilding 8
M - Vinyl Sheet FlooringPACM - Not SampledN/APOSND5Good200 SFThe Linoleum is Presumed to be Asbestos-Containing Based on Prior Sampling DataBuilding 8
M - Asphalt Roof ShinglePACM - Not SampledN/APOSND5Good1,500 SFRoof Shingles on Building are Presumed to be Asbestos-ContainingBuilding 8
M - Mastic Coating on SurfacePACM - Not SampledN/APOSND5GoodNot QuantifiedMiscellaneous Wall and Ceiling Mastics are Presumed to be Asbestos-ContainingBuilding 8
M - Fire DoorsPACM - Not SampledN/APOSND5GoodNot QuantifiedFire Doors Throughout the Facility are Presumed to be Asbestos-ContainingBuilding 10
M - Other, Not Listed (add description)PACM - Not SampledN/APOSND5GoodNot QuantifiedMiscellaneous Packings and Gaskets are Presumed to be Asbestos-ContainingBuilding 12
M - Vinyl Floor TilePACM - Not SampledN/APOSND5Good1,100 SFThese Floor Tiles are Presumed to be Asbestos-Containing Based on Prior Sample DataBuilding 12
M - Floor Tile MasticPACM - Not SampledN/APOSND5Good1,100 SFThe Black Floor Tile Mastic is Presumed to be Asbestos-Containing Based on Prior Sampling DataBuilding 12
M - Floor Tile MasticPACM - Not SampledN/APOSND5Good1,100 SFThe Black Floor Tile Mastic is Presumed to be Asbestos-Containing Based on Prior Sampling DataBuilding 12
M - Cove Base MasticPACM - Not SampledN/APOSND5Good1,380 LFThe Cove Base Mastic is Presumed to be Asbestos-Containing Based on Prior Sample DataBuilding 12
T - Pipe Insulation (Fittings, Elbows, Runs)PACM - Not SampledN/APOSND5GoodNot QuantifiedPipe Joint insulation Compounds are Presumed to be Asbestos-Containing Based on Prior Sampling DataBuilding 12
T - Pipe Insulation (Corrugated Air-Cell, Block, etc.)PACM - Not SampledN/APOSND5GoodNot QuantifiedThe Pipe Insulation is Presumed to be Asbestos-Containing Based on Prior Sampling DataBuilding 12
M - Fire BrickPACM - Not SampledN/APOSND5GoodNot QuantifiedFire Bricks are Presumed to be Asbestos-ContainingBuilding 12
M - Asphalt Roof ShingleNot SampledN/APOSND5Good9,000 SFExterior Roofing MaterialsBuilding 12
M - Mastic Coating on SurfaceNot SampledN/APOSND5GoodNot QuantifiedMiscellaneous Wall/Ceiling MasticsBuilding 12
M - Fire DoorsNot SampledN/APOSND5GoodNot QuantifiedFire Doors Assumed to be ACMBuilding 12
M - Elevator Brake ShoesNot SampledN/APOSND5GoodOne Elevator CabElevator Brake Systems are Assumed to Contain Asbestos PadsBuilding 12
M - Other, Not Listed (add description)Not SampledN/APOSND5GoodNot QuantifiedMiscellaneous Packings and GasketsBuilding 12
M - Floor Tile MasticNot SampledN/APOSND5Good2,000 SFBlack Floor Tile Mastic was found to be Asbestos-Containing by Previous SamplingBuilding 15
M - Vinyl Floor TilePACM - Not SampledN/APOSND5Good18,500 SFThese Floor Tiles are Presumed to be Asbestos-Containing Based on Prior Sample DataBuilding 15
M - Floor Tile MasticPACM - Not SampledN/APOSND5Good18,500 SFThe Black Floor Tile Mastic is Presumed to be Asbestos-Containing Based on Prior Sampling DataBuilding 16
M - Cement WallboardPACM - Not SampledN/APOSND5GoodNot QuantifiedThe Cementitious Paneling is Presumed to be Asbestos-Containing Based on Prior Sampling DataBuilding 16
T - HVAC Duct InsulationPACM - Not SampledN/APOSND5GoodNot QuantifiedThe Duct Insulation and Duct Wrap is Presumed to be Asbestos-Containing Based on Prior Sampling DataBuilding 16
T - Pipe Insulation (Fittings, Elbows, Runs)PACM - Not SampledN/APOSND5GoodNot QuantifiedPipe Joint insulation Compounds are Presumed to be Asbestos-Containing Based on Prior Sampling DataBuilding 16
T - Pipe Insulation (Corrugated Air-Cell, Block, etc.)PACM - Not SampledN/APOSND5GoodNot QuantifiedThe Pipe Insulation is Presumed to be Asbestos-Containing Based on Prior Sampling DataBuilding 23
T - Pipe Insulation (Corrugated Air-Cell, Block, etc.)Not SampledN/APOSND1Significantly Damaged8,617 SFAsbestos Debris Presumed to be Present in Floor of Crawlspace Encased Under Concrete Based on Prior Sampling DataBuilding 23
M - Roofing ShinglesIdentified in prior report.NAPOSND5Good3,000 SFRoofing Materials (i.e., roofing felt, tar, shingles, aluminum roof coating, roofing cement, etc.) were not sampled (at the request of the Health and Safety Officer for the Huntington, West Virginia Campus). Previous reports have identified the roofing cement found at each railing pitch pockets at the roof edge and the aluminum roof coating as asbestos-containing materials.Building 23
M - Fire DoorsPresumedNAPOSND5GoodNot QuantifiedMetal Fire DoorsBuilding 23
M - Roofing ShinglesPresumedNAPOSNot Determined5Good700 SFRoofing Materials (i.e., roofing felt, tar, shingles, etc.) were not sampled (at the request of the Health and Safety Officer for the Huntington, West Virginia Campus), therefore this material is presumed to be asbestos-containing.Building 23
M - Fire DoorsPresumedNAPOSNot Determined5GoodNot QuantifiedMetal Fire DoorsBuilding 23
M - Construction MasticsPresumedNAPOSNot Determined5GoodNot QuantifiedMiscellaneous Wall/Ceiling MasticsBuilding 23
M - Other, Not Listed (add description)PresumedNAPOSNot Determined5GoodNot QuantifiedMiscellaneous Packings and Gaskets related to the mechanical and plumbing systems.Building 23
T - Mastic Coating on Thermal Pipe Jacket CoverHuntington-102809-23-PH-249Penthouse2-10%Chrysotile5GoodNot QuantifiedLayer 1 - White Endcap Mastic on Pipe InsulationBuilding 23
T - Mastic Coating on Thermal Pipe Jacket CoverHuntington-102809-23-PH-250PenthousePOSChrysotile5GoodNot QuantifiedLayer 1 - White Endcap Mastic on Pipe InsulationBuilding 23
M - Floor Tile MasticHuntington-102809-23-2-2652nd Floor Hallway2-10%ChrysotileN/AGood25,500 SFLayer 2 - Yellow and Black Floor Tile Mastic Associated with HA 10Building 23
M - Floor Tile MasticHuntington-102809-23-2-2662nd Floor HallwayPOSChrysotileN/AGood25,500 SFLayer 2 - Yellow and Black Floor Tile Mastic Associated with HA 10Building 23
M - Floor Tile MasticHuntington-102809-23-2-2672nd Floor HallwayPOSChrysotileN/AGood25,500 SFLayer 2 - Yellow and Black Floor Tile Mastic Associated with HA 10Building 23
M - Floor Tile MasticHuntington-102809-23-2-2682nd Floor Hallway2-10%ChrysotileN/AGood25,500 SFLayer 2 - Yellow and Black Floor Tile Mastic Associated with HA 12Building 23
M - Floor Tile MasticHuntington-102809-23-2-2692nd Floor HallwayPOSChrysotileN/AGood25,500 SFLayer 2 - Yellow and Black Floor Tile Mastic Associated with HA 12Building 23
M - Floor Tile MasticHuntington-102809-23-2-2702nd Floor HallwayPOSChrysotileN/AGood25,500 SFLayer 2 - Yellow and Black Floor Tile Mastic Associated with HA 12Building 23
M - Asphalt Roof ShingleNot SampledN/APOSNot Determined5Good18,000 SFExterior Roofing MaterialsBuilding 25
M - Mastic Coating on SurfaceNot SampledN/APOSNot Determined5GoodNot QuantifiedMiscellaneous Wall/Ceiling MasticsBuilding 25
M - Fire DoorsNot SampledN/APOSNot Determined5GoodNot QuantifiedFire Doors Assumed to be ACMBuilding 25
M - Elevator Brake ShoesNot SampledN/APOSNot Determined5GoodTwo Elevator CabsElevator Brake Systems are Assumed to Contain Asbestos PadsBuilding 25
M - Other, Not Listed (add description)Not SampledN/APOSNot Determined5GoodNot QuantifiedMiscellaneous Packings and GasketsBuilding 26
M - Laboratory Hoods/Table TopsNot SampledN/APOSNot Determined5GoodNot QuantifiedLaboratory Fume HoodsBuilding 26
M - Vinyl Floor TileNot SampledN/APOSNot Determined5Good100 SF12" x 12" Brown Vinyl Floor Tiles with Black and Orange StreaksBuilding 26
M - Floor Tile MasticNot SampledN/APOSNot Determined5Good100 SFBlack Floor Tile Mastic Associated with HA 35Building 26
M - Roofing ShinglesPresumedNAPOSNot Determined5Good500 SFRoofing Materials (i.e., roofing felt, tar, shingles, etc.) were not sampled (at the request of the Health and Safety Officer for the Huntington, West Virginia Campus), therefore this material is presumed to be asbestos-containing.Building 27
M - Fire DoorsPresumedNAPOSNot Determined5Good38 DoorsMetal Fire Doors and Elevator DoorsBuilding 27
M - Construction MasticsPresumedNAPOSNot Determined5GoodNot QuantifiedMiscellaneous Wall/Ceiling MasticsBuilding 27
M - Elevator Brake ShoesPresumedNAPOSNot Determined5GoodTwo Elevator CabsElevator Brake Systems are presumed to exist throughout the building. Since this material was unable to be confirmed due to the excessive amount of damage that would be caused to confirm or deny this material, this material is presumed to contain asbestos, until sampling warrants otherwise.Building 34
M - Asphalt Roof ShingleNot SampledN/APOSNot Determined5Good1,300 SFExterior Roofing MaterialsBuilding 34
M - Mastic Coating on SurfaceNot SampledN/APOSNot Determined5GoodNot QuantifiedMiscellaneous Wall/Ceiling MasticsBuilding 34
M - Fire DoorsNot SampledN/APOSNot Determined5Good1 DoorFire Doors Assumed to be ACMBuilding 34
M - Other, Not Listed (add description)Not SampledN/APOSNot Determined5GoodNot QuantifiedMiscellaneous Packings and GasketsBuilding 34
M - Asphalt Roof ShingleNot SampledN/APOSNot Determined5Good200 SFExterior Roofing MaterialsBuilding 34
M - Fire DoorsNot SampledN/APOSNot Determined5Good1 DoorFire Doors Assumed to be ACMBuilding 34
M - Other, Not Listed (add description)Not SampledN/APOSNot Determined5GoodNot QuantifiedMiscellaneous Packings and GasketsBuilding 34
M - Vinyl Floor TileHuntington-093009-34-01-041st Floor Office2-10%Chrysotile5Good288 SFLayer 1 - 12" x 12" White Vinyl Floor Tiles with Grey StreaksBuilding 34
M - Floor Tile MasticHuntington-093009-34-01-041st Floor Office<1.0%ChrysotileN/AGoodN/ALayer 2 - Black Floor Tile Mastic Associated with HA 2Building 34
M - Vinyl Floor TileHuntington-093009-34-01-051st Floor Office2-10%Chrysotile5Good288 SFLayer 1 - 12" x 12" White Vinyl Floor Tiles with Grey StreaksBuilding 34
M - Floor Tile MasticHuntington-093009-34-01-051st Floor Office<1.0%ChrysotileN/AGoodN/ALayer 2 - Black Floor Tile Mastic Associated with HA 2Building 34
M - Vinyl Floor TileHuntington-093009-34-01-061st Floor Office2-10%Chrysotile5Good288 SFLayer 1 - 12" x 12" White Vinyl Floor Tiles with Grey StreaksTunnels
M - Floor Tile MasticHuntington-093009-34-01-061st Floor Office<1.0%ChrysotileN/AGoodN/ALayer 2 - Black Floor Tile Mastic Associated with HA 2Tunnels
M - Caulking/PuttiesHuntington-093009-34-01-09Exterior<1.0%ChrysotileN/AGoodN/AWhite Exterior Window Caulking
M - Caulking/PuttiesHuntington-093009-34-01-10Exterior<1.0%ChrysotileN/AGoodN/AWhite Exterior Window Caulking
M - Built-up RoofingNot SampledN/APOSNot Determined5Good2,240 SFExterior Roofing Materials
M - Mastic Coating on SurfaceNot SampledN/APOSNot Determined5GoodNot QuantifiedMiscellaneous Wall/Ceiling Mastics
M - Fire DoorsNot SampledN/APOSNot Determined5GoodNot QuantifiedFire Doors Assumed to be ACM
M - Other, Not Listed (add description)Not SampledN/APOSNot Determined5GoodNot QuantifiedMiscellaneous Packings and Gaskets
T - Pipe Insulation (Fittings, Elbows, Runs)PACM - Not SampledN/APOSNot Determined1DamagedNot QuantifiedPipe Joint insulation Compounds are Presumed to be Asbestos-Containing Based on Prior Sampling Data
T - Pipe Insulation (Corrugated Air-Cell, Block, etc.)PACM - Not SampledN/APOSNot Determined1DamagedNot QuantifiedThe Pipe Insulation is Presumed to be Asbestos-Containing Based on Prior Sampling Data